0006 Attachment 3 - Architecture Addendum 1 drawings.pdf
PDF 276 KB Posted
- Solicitation number
- 36C77622R0121
About this file
This document contains architectural drawings and notes for a parking garage construction project for the Department of Veterans Affairs in West Haven, Connecticut. The drawings provide details on the garage layout and design, including parking space allocation by level, dimensions, slopes, stairwells and elevators. Notes call out coordination requirements with structural, mechanical, electrical and other building systems. Reference is made to related specifications, engineering drawings and consultants for additional information.
The related federal contract opportunity is a solicitation for design-bid-build construction of the West Haven parking garage. Solicitation number 36C77622R0121 was issued by the Department of Veterans Affairs Office of Information and Technology Service Center. Responses were due on a specified date. The selected contractor will be responsible for building the parking garage in accordance with the architectural drawings and specifications.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
A. REFERENCE STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION
AND ELECTRICAL FOR COORDINATION ITEMS. COORDINATE AS REQUIRED
INCLUDING NECESSARY FRAMING, BLOCKING, ETC.
B. VERIFY EXISTING FIELD CONDITIONS PRIOR TO BEGINNING WORK, AND
REPORT DISCREPANCIES IMMEDIATELY TO ARCHITECT FOR CLARIFICATION.
C. ALL DIMENSIONS SHOWN ARE TO FACE OF WALL FRAMING/ MASONRY
UNLESS NOTED OTHERWISE. DIMENSIONS DESIGNATES AS "CLR" OR
"CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF
FINISH.
D. COLUMN DIMENSIONS ARE FOR REFERENCE AND SHALL BE VERIFIED IN THE
FIELD.
E. ALL HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE
WITH ALL REQUIREMENTS OF ARCHITECTURAL BARRIERS ACT GUIDELINES
AND ALL CODES AND REGULATIONS HAVING JURISDICTION, THE MOST
STRINGENT SHALL PREVAIL.
F. PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER ABA REQUIREMENTS.
G. WHERE NO DIMENSION IS INDICATED, FINISH DOORS 6" FROM EDGE OF
STUD FRAMING AT CORNERS UNLESS OTHERWISE NOTED.
H. DIMENSIONS INDICATED AS 'VIF' MAY INCREASE OR DECREASE TO MATCH
FIELD CONDITIONS. ALL OTHER DIMENSIONS WITHIN THE DIMENSION
STRING MUST BE MAINTAINED.
1. PARKING ATTENDANT BOOTH, RE: SPECIFICATIONS AND DRAWINGS FOR
MORE INFORMATION. BASIS OF DESIGN: PAR-KUT MODEL 75HCG
2. PARKING CONTROL BARRIER GATE, RE: SPECIFICATIONS AND ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
3. LOCATION FOR AUTOMATIC DOOR OPERATOR DOOR ACTUATOR. RE: DOOR
SCHEDULE AND ENGINEERING DRAWINGS FOR MORE INFORMATION.
4. INTERCOM PEDESTAL, RE: ELECTRICAL DRAWINGS FOR MORE INFORMATION.
5. SNOW CHUTE, RE:STRUCTURAL DRAWINGS
6. SHOW CHUTE GATE, RE: ELEVATIONS, DETAILS, AND STRUCTURAL
DRAWINGS.
7. AREA FOR SNOW REMOVAL WITHIN PARKING STALLS.
8. FLOOR DRAIN, RE: PLUMBING FOR MORE INFORMATION
9. STORMWATER DETENTION VAULT, REFER TO ENGINEERING DRAWINGS FOR
MORE INFORMATION.
10. APPROXIMATE LOCATION OF HYDRAULIC ELEVATOR PIPING EITHER BELOW
SLAB OR HUNG FROM STRUCTURE ABOVE. PROVIDE HEAT TRACE ON
OVERHEAD LINES COORDINATE WITH VA.
11. HYDRAULIC ELEVATOR EQUIPMENT, RE: ELECTRICAL DRAWINGS FOR MORE
INFORMATION.
12. PROVIDE FLUID APPLIED, WATERPROOF, TRAFFIC BEARING ELASTOMERIC
MEMBRANE FOR THE AREA SHADED.
ARCHITECTURAL GENERAL NOTES
ARCHITECTURAL PLAN NOTES
NOTE: ALL KEYNOTES MAY NOT BE REPRESENTED ON EACH SHEET.
AE401
1 2 3 4 5 6 7 8
A
B
C
1.5
AE311
AE201
AE201
AE201
AE201
AE301
AE301
AE301
AE301
AE401
3.3% SLOPE
3% SLOPE
B.6
20' - 0" 26' - 0" 36' - 0" 36' - 0" 36' - 0" 36' - 0" 36' - 0" 46' - 0"
272' - 0"
4'
AE311
1/4" / 12"
/4
/4
EAST STAIR
LEVEL 2 - LOBBY
ELEV 1
ELEV 2
WEST STAIR
AE311
AE311
AE20
34' - 10"
6'
12' - 1 1/2"
8'
6' - 0"
/4
10' - 0"
20' - 0"
PARKING EFFICIENCY = 340SF/SPACE
STANDARD SPACE = 9'-0" X 18'-0" @ 90°
ADA = 9'-0" X 18'-0" W/5'-0" ACCESIBLE AISLES @ 90°
ADA VAN ACCESSIBLE = 11'-0" X 18'-0" W/5'-0" ACCESIBLE AISLES @ 90°
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs \a o g rz e w a lla
\D o c u m e n ts \2
.1
A v
A ro g rz e w a lla
.r v t
/1 /2
:3
:4
P M
AE102
LEVEL 2 ARCHITECTURAL PLAN
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
950 CAMPBELL AVENUE, WEST HAVEN, CT 06516
689-409
FACILITIES MANAGEMENT
01/12/2022 AO JDJ
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
856.429.4000
SCALE: 3/32" = 1'-0"AE102
1 LEVEL 2 ARCHITECTURAL PLAN
GARAGE PARKING SUMMARY
DESCRIPTION COUNT
LEVEL 1
ADA VAN ACCESSIBLE PARKING SPACE 3
PARKING SPACE 92
LEVEL 2
ADA PARKING SPACE 9
PARKING SPACE 92
LEVEL 3
ADA PARKING SPACE 9
PARKING SPACE 92
LEVEL 4
ADA PARKING SPACE 9
PARKING SPACE 92
LEVEL 5 - WEST
PARKING SPACE 5
GARAGE TOTAL: 403
LEVEL 4
EL 139'-0 3/4"
LEVEL 3
EL 127'-8 3/4"
LEVEL 2
EL 116'-4 3/4"
LEVEL 1
EL 105'-0 3/4"
LEVEL 4 - WEST
EL 133'- 0 3/4"
LEVEL 3 - WEST
EL 121'- 8 3/4"
LEVEL 2 - WEST
EL 110'- 4 3/4"
LEVEL 1 - WEST
EL 99'-0 3/4"
LEVEL 5 - WEST
EL 144'- 4 3/4"
ISOMETRIC VIEW KEY
N
PLAN
NORTH
N
TRUE
NORTH
Revisions: Date:
| Sheets |
| AE102 - LEVEL 2 ARCHITECTURAL PLAN |