Attachment_1_-_CU101.pdf
PDF 531 KB Posted
- Solicitation number
- 2502001
- Issued by
- Lake County, Florida
About this file
This document is a Utility Plan drawing for the Veterans Road Hangar Infrastructure project at Leesburg International Airport, with the City of Leesburg as the Authority Having Jurisdiction (AHJ). The project involves infrastructure improvements including new water mains (6-inch, 8-inch, and 12-inch), sanitary sewer lines, electrical conduits, and utility connections. The plan details the installation of five sanitary manholes, water blowoffs, electrical pull boxes, and transformer pads, with specific routing for water, sewer, and electrical utilities. The drawing is dated June 2025, with a bid addendum on July 15, 2025, and is designed by AVCON, Inc. for the airport located at 8807 Airport Blvd, Leesburg, FL 34788.
The utility plan includes comprehensive notes outlining contractor responsibilities, such as contacting utilities 48 hours prior to work, obtaining necessary permits, and following specific installation guidelines for underground utilities. The project involves multiple utility types including potable water, electric/power, sanitary sewer, reclaim water, and gas. Specific technical requirements are provided for pipe depths, corrosion protection, and utility connection methods, with the City of Leesburg responsible for certain water main connections. The plan indicates that utility allowances have been included to account for unforeseen expenses, permit costs, and additional materials not initially specified.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
W
W
W
W
W
W
W
W
W
W
W W W W
W W
W
W
W
W
W
W
W
W
W
W
W
W
W W
W W W W W W W W W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
R W
RW
RW
RW
RW
RW
RW
RW
RW
R W
R W
R W
R W
R W
R W
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW RW RW RW RW RW
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
G
AS
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
SS
SS
SS
SS
S
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
S
S
E E
E
E
W
W
W
W W
W
W W
CO
W W
W W
W W
W W
W W
W W W W W W W W
W W
W W
W W
W W
W W
W W
W W
W W
W W W
W W
W W
BFO BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
BFO
RW
RW
RW
RW RW
RW
RW
RW
RW
RW
RW
RW
RW
RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UG
E
UG
E
UGE
UGE
UGE UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE UGE UGE UGE UGE UGE
W
E
UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE
W W W W
1-TK
1-TK
1-TK
1-TK
2-TK
UGE
UG
E
UG
E
UG
E
U G E
U G E
U G E
U G E
S
S
S
S
U G E
U G E
U G E
U G E
U G E
U G E
U G E
U G E
U G E
U G E
U G E
U G
E
UGE
UGE
U G E
U G E
UGE
U G E
U G E
U G E
U G E
U G E
U G E
UGE
E
W W
UGE
U G E
U G E
U G E
U G E
U G E
U G E
U G E
U G E
U G E
U G E
S
E E
E
E
E
CO
CO
CO
CO
CU101
U
TI
LI
TY
P
LA
N
1 2 3 4
1 2 3 4
A
B
C
A
B
C
A1 UTILITY PLAN A4 KEY PLAN
B4 GENERAL UTILITY NOTES
DJN
PV
PV, DJN
JUNE 2025
AS SHOWN
SEAL
SHEET
AVCON PROJECT NUMBER
APPROVED:
DESIGNED:
DRAWN:
DATE:
SCALE:
N O
D
AT
E
R
EV
IS
IO
N S
D
ES
C R
IP
TI
O N
VE
TE
R
AN
S R
D H
AN
G
AR
IN
FR
AS
TR
U
C
TU
R E
LE
ES
BU
R
G
IN
TE
R
N
AT
IO
N
AL
A
IR
PO
R T
(K
LE
E) , 8
AI
R
PO
R
T
BL
VD
, L
EE
SB
U R
G , F
L
2024.236.02
DANIEL J. NICKOLS, JR., P.E.
Lic. No. 78634
6-
9-
IS
SU
ED
T O
B
ID
D R
AW
IN
G S
AVCON, INC.
ENGINEERS & PLANNERS
5555 E. MICHIGAN ST., SUITE 200 - ORLANDO, FL 32822-2779
OFFICE: (407) 599-1122 - FAX: (407) 599-1133
CORPORATE CERTIFICATE OF AUTHORIZATION NUMBER: 5057
www.avconinc.com
IS
SU
ED
T
O B
ID
D
R
AW
IN
G
S
NORTH
GENERAL UTILITY NOTES:
A. CONTRACTOR SHALL CONTACT ALL PUBLIC AND PRIVATE UTILITIES 48-HOURS PRIOR TO COMMENCING WORK. COST OF REPLACEMENT AND REPAIR OF EXISTING UTILITIES DAMAGED AS A RESULT OF THE
CONTRACTOR'S OPERATION SHALL BE THE CONTRACTOR'S RESPONSIBILITY.
B. UTILITY VALVES AND CONNECTIONS ARE SCHEMATIC. LOCATIONS SHALL BE DETERMINED DURING
CONSTRUCTION.
C. CONTRACTOR SHALL OBTAIN CITY OF LEESBURG UNDERGROUND UTILITY PERMIT PRIOR TO BEGINNING
WORK.
D. OUT-OF-SERVICE (ABANDONED) BURIED UTILITIES ENCOUNTERED WITHIN THE PROPOSED PROJECT SHALL BE REMOVED AS DIRECTED BY THE UTILITY'S OWNER, INCIDENTAL TO P-152, UNCLASSIFIED
EXCAVATION.
E. CONFLICTS BETWEEN UNDERGROUND UTILITIES, I.E. WATER, ELECTRICAL, COMMUNICATIONS, GAS, AND STORM OR SANITARY SEWERS SHALL BE RESOLVED BY ADJUSTING THE UNDERGROUND UTILITIES AS NECESSARY, AND IS INCLUSIVE IN CONTRACTORS COST. GRAVITY SEWERS SHALL NOT BE ADJUSTED
WITHOUT PRIOR APPROVAL OF THE ENGINEER AND THE CITY OF LEESBURG.
F. ALL FITTINGS, VALVES, AND HYDRANT BRANCHES SHALL BE RESTRAINED AGAINST MOVEMENT BY USING
RESTRAINED JOINT SYSTEMS, PER NFPA 24: 8.6.1.
G. CORROSION PROTECTION FOR ALL UNDERGROUND BOLTED JOINT ACCESSORIES SHALL BE CLEANED
AND THOROUGHLY COATED WITH CORROSION-RETARDING MATERIAL AFTER INSTALLATION IN
ACCORDANCE WITH NFPA 24: 10.8.3.5.
H. THE MINIMUM DEPTH OF COVER TO PREVENT MECHANICAL DAMAGE SHALL BE 30-INCHES MEASURED FROM THE FINAL GRADE TO THE TOP OF THE PIPE OF ALL UNDERGROUND FIRE AND WATER MAINS. PIPE UNDER VEHICULAR TRAFFIC AREAS SHALL BE BURIED AT A MINIMUM DEPTH OF 3-FEET; IN ACCORDANCE
WITH NFPA 24: 10.4.
I. ANY PRIVATE DEDICATED UNDERGROUND FIRE MAINS AND FIRE HYDRANTS MUST BE INSTALLED BY A LICENSED FIRE CONTRACTOR CLASS I, II, OR V. COMBINATION FIRE MAINS (SHARED DOMESTIC AND FIRE PROTECTION SERVICE) AND FIRE HYDRANTS UP TO THE DEDICATED FIRE PROTECTION SYSTEM "POINT OF SERVICE" CAN BE INSTALLED BY A LICENSED UNDERGROUND UTILITY/EXCAVATION CONTRACTOR, GENERAL CONTRACTOR, OR PLUMBING CONTRACTOR. [FLORIDA STATUTES 633.021, 633.539, 489.105]
J. RELOCATION OF EXISTING UNDERGROUND WATER MAINS SHALL BE IN ACCORDANCE WITH ALL
APPLICABLE REQUIREMENTS OUTLINED IN NFPA 24, CURRENT EDITION, STANDARDS FOR THE
INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES.
K. CONTRACTOR IS RESPONSIBLE FOR UNDERGROUND ELECTRICAL CONDUIT, ELECTRICAL PULL BOXES, AND TRANSFORMER CONCRETE PAD INSTALLATION.
L. WATER MAIN CONNECTIONS SHALL BE MADE BY THE CITY OF LEESBURG, AND PAID FOR BY THE CONTRACTOR, ITEM SP-01, C-900, HIGH PRESSURE POTABLE WATER MAIN, INSTALLED TESTED, AND COMPLETE. IN AN EFFORT TO REDUCE THE CITY COSTS THAT ARE PASSED ON TO THE CONTRACTOR, THE CONTRACTOR MAY EXCAVATE AND EXPOSE THE WATER MAIN CONNECTION POINTS. COORDINATE WITH THE CITY OF LEESBURG AND THE ENGINEER TO ENSURE THAT EXCAVATIONS AND WATER MAIN
CONNECTIONS ARE NOT OPEN OR EXPOSED LONGER THAN NECESSARY/NEEDED.
M. WHEN DIGGING IN THE VICINITY OF EXISTING UTILITIES, KNOWN OR UNKNOWN, THE CONTRACTOR IS
ENCOURAGED TO HAND DIG TO AVOID CONFLICT AND/OR INCIDENT.
N. UTILITY ALLOWANCES HAVE BEEN INCLUDED IN THE PROJECT TO ACCOUNT FOR UNFORESEEN EXPENSES, PERMIT COSTS, OR ADDITIONALLY REQUIRED MATERIALS NOT SPECIFIED HEREIN. THIS
INCLUDES UTILITY ADJUSTMENTS FOR UNFORESEEN UTILITY CONFLICTS.
UTILITIES: POTABLE WATER, ELECTRIC/POWER, SANITARY SEWER,
RECLAIM WATER, AND GAS.
THE AUTHORITY HAVING JURISDICTION (AHJ) IS THE CITY OF LEESBURG.
TA
XI
W
AY
K
TA
XI
W
AY
K
FIRE STATION
VETERANS ROAD
PARKING LOT
PROPOSED TAXILANE 2
PR
O
PO
SED
R O
AD
W
AY
U.S. HIGHWAY 441
NEW TRANSFORMER TO BE
INSTALLED BY CITY OF LEESBURG,
CONNECT PROPOSED
UNDERGROUND ELECTRICAL
SERVICE LINES, INCIDENTAL TO
ITEM SP-03. CONTRACTOR TO
INSTALL AHJ PROVIDED
CONCRETE TRANSFORMER PAD
AND STUB UP ELECTRICAL
CONDUITS AS DIRECTED BY THE
AHJ, SEE DETAIL B1/CU504 AND
B3/CU504. (TYP. OF 3)
NEW 2" PVC ELECTRICAL CONDUIT, ITEM
SP-03, INSTALL 2", PVC ELECTRCIAL
CONDUIT IN TURF, WITH CONTRACTOR
PROVIDED MULE TAPE. SEE DETAIL
A1/CU501.
NEW 8-INCH, DR-18 C-900, HIGH PRESSURE
POTABLE WATER MAIN, INSTALLED,
TESTED, AND COMPLETE, ITEM SP-01. SEE
DETAIL A3/CU502.
PROPOSED ROADWAY
LIGHTING TO BE INSTALLED
BY OTHERS. CONTRACTOR
SHALL INSTALL CONDUIT AND
STUB UP AT IDENTIFIED
LOCATIONS FOR
CONNECTION BY THE AHJ.
(TYP. OF 4)
NEW 12" X 8" X 12" HOT
TAP/ WET TAP
CONNECTING TO EXISTING
WATER MAIN, ITEM SP-01,
SEE DETAIL A4/CU502.
NEW GRAVITY SANITARY
FEEDER CLEAN OUTS, ITEM
SP-02, SEE DETAIL
B1/CU503, (TYP.)
PROP. SANITARY MANHOLE SMH-1,
ITEM SP-02, PRECAST OR CAST IN
PLACE CONCRETE DOG HOUSE
SANITARY SEWER MANHOLE,
RIM ELEV: 70.74'
NE INV: 66.10'
W INV: 66.07'
E INV: 66.07'
SEE DETAIL A3/CU503.
PROP. SANITARY MANHOLE
SMH-2, ITEM SP-02, PRECAST
CONCRETE SANITARY
SEWER MANHOLE,
RIM ELEV: 71.22'
SW INV: 66.65'
NW: 66.65'
NE INV: 66.65'
SEE DETAIL B3/CU503.
PROP. SANITARY MANHOLE
SMH-3, ITEM SP-02, PRECAST
CONCRETE SANITARY
SEWER MANHOLE,
RIM ELEV: 71.89'
SW INV: 67.31'
NW INV: 67.31'
NE INV: 67.31'
SEE DETAIL B3/CU503.
PROP. SANITARY MANHOLE
SMH-4, ITEM SP-02, PRECAST
CONCRETE SANITARY
SEWER MANHOLE,
RIM ELEV: 72.56'
SW INV: 67.96'
NW INV: 67.96'
NE INV: 67.96'
SEE DETAIL B3/CU503.
NEW MULLER MODEL SUPER CENTURION BLUE FIRE
HYDRANT, ITEM SP-01, FIRE HYDRANT ASSEMBLY,
INSTALLED, TESTED, AND COMPLETE WITH A 2-1/2"
SIAMESE FIRE DEPARTMENT CONNECTION WITH
LOCKING CAPS, SEE DETAIL C4/CU502 AND C1/CU503,
(TYP. of 2).
NEW 12" X 12" X 12" HOT-TAP/WET-TAP
CONNECTING TO EXISTING WATER MAIN,
ITEM SP-01, SEE DETAIL A4/CU502.
NEW 12" X 8" X 12" HOT TAP/WET
TAP CONNECTING TO EXISTING
WATER MAIN, ITEM SP-01, SEE
DETAIL A4/CU502.
NEW, 8-INCH, DR-18 C-900, HIGH PRESSURE
POTABLE WATER MAIN, INSTALLED,
TESTED, AND COMPLETE, ITEM SP-01. SEE
DETAIL A3/CU502.
NEW 12-INCH, DR-18 C-900,
HIGH PRESSURE POTABLE
WATER MAIN, INSTALLED,
TESTED, AND COMPLETE,
ITEM SP-01. SEE DETAIL
A3/CU502.
NEW 6" DR 18, C-900, HIGH PRESSURE
POTABLE WATER MAIN, INSTALLED,
TESTED, AND COMPLETE, ITEM SP-01. SEE
DETAIL A1/CU502.
NEW 12" X 6" X 12" HOT
TAP/WET TAP
CONNECTING TO EXISTING
WATER MAIN, ITEM SP-01,
SEE DETAIL C3/CU502.
NEW 12" X 6" X 12" HOT
TAP/WET TAP
CONNECTING TO EXISTING
WATER MAIN, ITEM SP-01,
SEE DETAIL C3/CU502.
PROPOSED POWER SHALL
CONNECT TO EXISTING
PRIMARY CABLE, CITY OF
LEESBURG UTILITIES SHALL
MAKE CONNECTIONS, ITEM
SP-03.
PROPOSED POWER LINE
SHALL CONNECT TO
EXISTING ELECTRICAL
PULL BOX, ITEM SP-03.
NEW TAXIWAY EDGE LIGHT, ITEM
L-125, NEW L-861(L), LED TAXIWAY
ELEVATED EDGE LIGHT AND BASE
CAN INSTALLED IN EARTH, (TYP.).
SEE DETAIL C3/CU501
NEW 2" PVC CONDUIT, ITEM L-110,
NON-ENCASED ELECTRICAL
CONDUIT, 2" PVC, SEE DETAIL
A1/CU501 AND B3/CU501
NORTH
PR
O
PO
SED
TAXILAN
E 1
NEW 6" PVC, SDR 26,
GRAVITY SEWER SERVICE
LINE, ITEM SP-02, (TYP.)
NEW WATER BLOWOFF, SEE
DETAIL C1/CU502, ITEM
SP-01, WATER BLOWOFF,
INSTALLED, TESTED, AND
COMPLETE, (TYP. OF 3)
PROP. SANITARY MANHOLE
SMH-5, ITEM SP-02, PRECAST
CONCRETE SANITARY
SEWER MANHOLE,
RIM ELEV: 72.88'
SW INV: 68.52'
NW INV: 68.52'
SEE DETAIL B3/CU503.
95 LF 6" PVC @
1.04%, ITEM SP-02
38 LF 6" PVC @
1.04%, ITEM SP-02
38 LF 6" PVC @
1.04%, ITEM SP-02
38 LF 6" PVC @
1.04%, ITEM SP-02
107 LF 8" PVC @
0.52%, ITEM SP-02
126 LF 8" PVC @
0.52%, ITEM SP-02
126 LF 8" PVC @
0.52%, ITEM SP-02
106 LF 8" PVC @
0.52%, ITEM SP-02
BLAST WALL
NEW 6" PVC, SDR 28,
GRAVITY SEWER SERVICE
LINE, ITEM SP-02, (TYP.)
NEW 6" PVC, SDR 28,
GRAVITY SEWER SERVICE
LINE, ITEM SP-02, (TYP.)
NEW 6" PVC, SDR 28,
GRAVITY SEWER SERVICE
LINE, ITEM SP-02, (TYP.)
L-823 AIRFIELD LIGHTING SPLICE TO
CONNECT TO EXISTING CIRCUIT. NEW
CIRCUITRY SHALL BE MEG TESTED
PRIOR TO CONNECTION.
CONTRACTOR SHALL HAND EXCAVATE, AND PROVIDE
AND INSTALL NEW CONDUIT AND CONDUCTOR SYSTEM,
BACKFILL AND SOD ACCORDINGLY, AND MAKE ALL
NECESSARY CONNECTIONS FOR A COMPLETE
WORKING SYSTEM IN PLACE.
L-823 AIRFIELD LIGHTING SPLICE TO
CONNECT TO EXISTING CIRCUIT. NEW
CIRCUITRY SHALL BE MEG TESTED
PRIOR TO CONNECTION.
CONTRACTOR SHALL LOCATE AND INTERCEPT THE
EXISTING CONDUIT SYSTEM AND EXTEND TO NEW
LIGHT BASE CAN. THE EXISTING CONDUIT SYSTEM
SHALL BE DEWATERED, CLEANED, AND
MANDRELLED. CONTRACTOR SHALL INCLUDE THE
DEWATERING, CLEANING, AND MANDRELLING IN
ITEM L-110.
1-TK
1C
1W2" 1-TK
1C 1W2"
SEE DETAIL B1/CU504 FOR
UTILITY CONFLICT DETAIL,
(TYP.)
SEE DETAIL B1/CU504 FOR
UTILITY CONFLICT DETAIL,
(TYP.)
NEW 6" X 6" X 6" "TEE"
SHALL BE INSTALLED ON
THE PROPOSED WATER
MAIN FOR FIRE HYDRANT
INSTALLATION, ITEM SP-01,
SEE DETAIL C3/CU502.
CONTRACTOR TO INSTALL
FULLY RESTORED BENDS AS
NEEDED.
7-
-2
BI
D
A D
D
EN
D U
M
SEE DETAIL C1/CU504 FOR
UTILITY CONFLICT DETAIL,
(TYP.)
NEW 12" X 6" X 12" "HOT-TAP/WET-TAP"
CONNECTING TO EXISTING WATER MAIN,
ITEM SP-01, SEE DETAIL A4/CU502.
NEW, CITY OF LEESBURG
PROVIDED, CONTRACTOR
INSTALLED, ELECTRICAL
PULLBOX, (TYP. OF 5)
SITE LIGHTING POLE TO BE
REINSTALLED BY THE AHJ.
CONTRACTOR TO PROVIDE
CONDUIT STUB UPS FOR AHJ
CONNECTIONS
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text 30'
AutoCAD SHX Text 60'
AutoCAD SHX Text 30'
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text 0'
| Sheets and Views |
| CU101 |
File details come from the government source that posted it. Updated .