This document contains civil demolition drawings and a construction haul route for the demolition of two Munitions Storage Magazines (Buildings 1411 and 1432) at Hill Air Force Base in Utah. The drawings, prepared by the U.S. Army Corps of Engineers Sacramento District, provide detailed demolition plans showing the buildings to be demolished, existing utilities, and site conditions. Key specifications include:

The demolition plan for each building indicates the removal of the structure, existing pavement, and underground electrical infrastructure from the igloo to the transformer. The documents specify that contractors must protect in-place existing water mains, trees, and other utilities not designated for removal. The haul route and staging area drawing shows an approximate 1-acre staging area, designated access gates, and the project site route. Notes emphasize contractor responsibilities for temporary drainage, grading, erosion control, site stabilization, and restoration of the site to original conditions upon project completion.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 1: Civil Demolition Drawings/ Construction Haul Route

ENGINE

C O

TT

O

N W

O O

D S

T.

ROY GATE

SO

U

TH

G

ATE R

D

SOUTH GATE

PROJECT SITE HAUL ROUTE

GEORGIA ST

APPROXIMATE STAGING AREA (1 AC)

ALABAMA ST

SE

R

VI

C

E

M

AP

LE

BEECHNUT

NOTES:

1. CONTRACTOR ACCESS WILL BE THROUGH DESIGNATED GATE AS SHOWN

ON PLANS.

2. LOCATION OF THE CONTRACTOR STAGING AREAS SHOWN is

APPROXIMATE. THE EXACT LOCATIONS WILL BE DETERMINED IN THE

FIELD BY THE CONTRACTING OFFICER.

3. NO BLADES OR BUCKETS SHALL BE ALLOWED TO CONTACT EXISTING

PAVEMENTS THAT ARE TO REMAIN. ONLY POWER SWEEPERS SHALL BE

ALLOWED TO REMOVE DEBRIS FORM THE SURFACE OF PAVEMENTS TO

REMAIN.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY DRAINAGE,

GRADING, EROSION CONTROL, STABILIZATION, AND UTILITY

CONNECTIONS IN STAGING AREAS AND SHALL RESTORE SITE TO

ORIGINAL CONDITIONS UPON COMPLETION.

5. ALL CONSTRUCTION AREAS SHALL BE CONSIDERED LAND DISTURBANCE

AREAS.

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

D R

AF

T

SU

BM

IT

TA

L

H

IL

L

AI

R F

O R

C E

BA

SE

, U

TA

H B1

AN

D

IG

LO

O

D

EM

O

LI

TI

O

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

A

PR

AN

SI

D

S.

M

IT

C

H

EL

L

S.

M

IT

C

H

EL

L

L.

N

EM

ET

Z

S.

M

IT

C

H

EL

L

G-001

H

AU

L R

O U

TE

A

N D

S

TA

G

IN

G A

R

EA

DEMOLISH BUILDING 1411

DEMOLISH

EXISTING

PAVEMENT

PROTECT TREES

IN-PLACE

W W W W W W W W W W W W

W W W W W W W W W W W W W W W W W W W W W W W

WWWWWWWWWWWWWWWWWWWWWWWW

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

E E E E E E E E

E E E E E E E E E E E E E E E E E E

E E

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

DEMOLISH EXISTING UNDERGROUND

ELECTRIC FROM IGLOO TO TRANSFORMER

PROTECT IN PLACE

NOTES:

1. SEE PERFORMANCE WORK STATEMENT (PWS) FOR

DEMOLITION DETAILS..

2. SEE BUILDING DESCRIPTION(S), PWS 3.0 DETAILED

DESCRIPTION OF SERVICES.

3. UTILITY LOCATIONS ARE APPROXIMATE.

CONTRACTOR WILL FIELD VERIFY LOCATIONS PRIOR

TO DEMOLITION.

4. PROTECT IN PLACE ALL EXISTING UTILITIES UNLESS

OTHERWISE NOTED.

BUILDING 1411 DEMOLITION PLAN

1"=30'

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

D R

AF

T

SU

BM

IT

TA

L

H

IL

L

AI

R F

O R

C E

BA

SE

, U

TA

H B1

AN

D

IG

LO

O

D

EM

O

LI

TI

O

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

A

PR

AN

SI

D

S.

M

IT

C

H

EL

L

S.

M

IT

C

H

EL

L

L.

N

EM

ET

Z

S.

M

IT

C

H

EL

L

CD101

BU

IL

D

IN

G

D

EM

O

LI

TI

O

N P

LA

N

W W

E E

LEGEND

EXISTING WATER MAIN

EXISTING PRIMARY UNDERGROUND ELECTRIC

EXISTING SECONDARY UNDERGROUND ELECTRIC

EXISTING PAD MOUNTED TRANSFORMER

ES ES

DEMOLISH BUILDING 1411

DEMOLISH EXISTING

PAVEMENT

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

E E

E E

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

DEMOLISH EXISTING UNDERGROUND

ELECTRIC FROM IGLOO TO TRANSFORMER

NOTES:

1. SEE PERFORMANCE WORK STATEMENT (PWS) FOR

DEMOLITION DETAILS.

2. SEE BUILDING DESCRIPTION(S), PWS 3.0 DETAILED

DESCRIPTION OF SERVICES.

3. UTILITY LOCATIONS ARE APPROXIMATE.

CONTRACTOR WILL FIELD VERIFY LOCATIONS PRIOR

TO DEMOLITION.

4. PROTECT IN PLACE ALL EXISTING UTILITIES UNLESS

OTHERWISE NOTED.

BUILDING 1432 DEMOLITION PLAN

1"=30'

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

D R

AF

T

SU

BM

IT

TA

L

H

IL

L

AI

R F

O R

C E

BA

SE

, U

TA

H B1

AN

D

IG

LO

O

D

EM

O

LI

TI

O

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

A

PR

AN

SI

D

S.

M

IT

C

H

EL

L

S.

M

IT

C

H

EL

L

L.

N

EM

ET

Z

S.

M

IT

C

H

EL

L

CD102

BU

IL

D

IN

G

D

EM

O

LI

TI

O

N P

LA

N

W W

E E

LEGEND

EXISTING WATER MAIN

EXISTING PRIMARY UNDERGROUND ELECTRIC

EXISTING SECONDARY UNDERGROUND ELECTRIC

EXISTING PAD MOUNTED TRANSFORMER

ES ES

File details come from the government source that posted it. Updated .