attachment-1-bid-3053-26.pdf
PDF 46 MB Posted
- Attached to
- CONTRACT: ROOFING REPLACEMENT SERVICES AT MURPHY DAM State and local contract opportunity
- Solicitation number
- Bid 3053-26
- Issued by
- Coos County, New Hampshire
About this file
Summary
This is a roofing replacement services solicitation from the New Hampshire Department of Administrative Services, Division of Procurement and Support Services, for the Murphy Dam Tender Residence located in Pittsburg, Coos County. The project involves comprehensive roof replacement for a historic two-floor home with attached two-car garage originally constructed in the mid-1800s, covering approximately 3,800 square feet of roofing surface. The scope of work includes complete removal of existing asphalt and metal roofing, repair or replacement of roof decking and associated structural elements, installation of new asphalt roof shingles with 30-mil minimum ice and water shield underlayment extending not less than 3 feet from roof edges, chimney repointing and new chimney cap installation, fascia and soffit repair or replacement, new gutter and downspout installation, and inspection and remediation of black mold in accordance with OSHA, EPA, and New Hampshire Department of Health and Human Services guidelines. The bid was distributed June 23, 2025, with a closing date of July 16, 2025, at 9:00 AM Eastern Time. The contract term is approximately one year from August 27, 2025, with potential two-year renewal extensions.
Contractors must provide all labor, materials, tools, and permits while ensuring compliance with applicable codes including the 2018 International Building Code with New Hampshire amendments and relevant state and federal regulations. All contractors must be certified for mold assessment and remediation and provide proof of insurance, workers' compensation coverage, and environmental compliance certifications. The project includes a 15% contingency in the pricing structure. No specific set-aside designations or incumbent vendor information is identified in the solicitation documents. Contractors must submit detailed documentation including vendor contact information, insurance verification, and a completed transmittal letter certifying legal and operational compliance. All work is subject to a one-year warranty from the date of substantial completion, with emphasis on first-class workmanlike quality and use of high-quality, sustainable materials with low volatile organic compound content.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| attachment_1_bid_3053_26.pdf | ||
| attachment_3_bid_3053_26.pdf | ||
| attachment_4_bid_3053_26.xlsx | XLSX spreadsheet | |
| attachment_2_bid_3053_26.pdf | ||
| bid_3053_26.pdf | ||
| bid-3053-26.pdf | ||
| attachment-2-bid-3053-26.pdf | ||
| attachment-3-bid-3053-26.pdf | ||
| addendum-3-bid-3053-26.pdf | ||
| attachment-4-bid-3053-26.xlsx | XLSX spreadsheet | |
| addendum-1-bid-3053-26.pdf | ||
| addendum-2-bid-3053-26.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING INDEX
GENERAL
G001 COVER SHEET
ARCHITECTURAL
A001 GENERAL NOTES, SYMBOLS, LEGENDS & ABBREVIATIONS
A101 PLANS
A201 ELEVATIONS
A301 SECTIONS
209 SENATE AVENUE, CAMP HILL, PENNSYLVANIA, 17011
L o c a l F ile
/8 /2
:0
:0
P
M
A u to d e s k D o c s
/0
N
H D
E S
L a k e p o rt D a m
T e n d e r H o u s e /0
A M u rp h y c e n tr a l_
R
.r v t
11/08/2024
PROJECT NUMBER: 073685
MURPHY DAM TENDER ROOF REPLACEMENT
NHDES
8-42 MURPHY DAM RD.
PITTSBURG, NH 03592
BID SET
C e n tr a l F ile B
IM
A
R
.r v t
P ro je c t N u m b e r:
BRICK
CONCRETE MASONRY UNITS
ACOUSTICAL CMU
CMIU
STRUCTURAL GLAZED
FACING TILE/ GLAZED CMU
CONCRETE
GYPSUM BOARD / GROUT
BATT INSULATION
RIGID INSULATION
COARSE AGGREGATE /
BALLAST
STEEL
ALUMINUM
FINISH LUMBER
DIMENSIONAL LUMBER
SHIM
PLYWOOD
TILE / ACOUSTIC PANEL
EARTH / SOIL
M888
SIM
101A
ROOM
101A
L-2
A
A a
W1
L1
A101
A101
A101
DETAIL REFERENCE
DRAWING ON WHICH DETAIL APPEARS
DOOR NUMBER REFERENCE
LINTEL TYPE REFERENCE
STRUCTURAL COLUMN REFERENCE
TOILET ACCESSORY REFERENCE
PARTITION TYPE NUMBER
WINDOW TYPE REFERENCE
LOUVER TYPE REFERENCE
ROOM SIGN REFERENCE
SHEET NOTE REFERENCE
DETAIL REFERENCE
SECTION REFERENCE
DRAWING ON WHICH SECTION APPEARS
WALL SECTION REFERENCE
SECTION REFERENCE
DRAWING ON WHICH SECTION APPEARS
BUILDING SECTION REFERENCE
ELEVATION REFERENCE
DRAWING ON WHICH ELEVATION APPEARS
EXTERIOR ELEVATION REFERENCE
CEILING TYPE
HEIGHT OF CEILING ABOVE FLOOR
CEILING SYSTEM REFERENCE
INTERIOR ELEVATION REFERENCE
MAGNETIC NORTH
BUILDING NORTH
NORTH ARROW REFERENCE
ROOM NAME
ROOM NUMBER
ROOM IDENTIFICATION REFERENCE
REVISION REFERENCE
A10
DRAWING ON WHICH DETAIL APPEARS
ELEVATION REFERENCE
R1
TYPE A
10'-0"
WALL PARTITION REFERENCE
PARTITION MODIFIER
PARTITION FIRE RATING
PARTITION HEAD CONFIGURATION
1. ALL WORK TO CONFORM TO REQUIREMENTS OF THE GOVERNING BUILDING CODE,
OSHA AND ALL OTHER APPLICABLE CODES, RULES, REGULATIONS, ORDINANCES,
ETC. IN THEIR LATEST EDITION. CONFORM ALL WORK TO REQUIREMENTS OF ALL
AUTHORITIES HAVING JURISDICTION.
2. ALL WORK THAT IS IMPLIED OR REASONABLY INFERRED BY THE DRAWINGS IS THE
RESPONSIBILITY OF THE CONTRACTOR. THE INCLUSION OF ANY AND ALL WORK
BY MENTION, NOTATION, DETAIL, ITEMIZATION OR IMPLICATION, HOWEVER BRIEF,
MEANS THAT THE CONTRACTOR TO PROVIDE AND INSTALL SAME AT NO
ADDITIONAL COST OR BURDEN TO THE OWNER. ALL WORK PERFORMED TO
INCLUDE ALL APPURTENANCES AND APPARATUS NORMALLY DEEMED TO BE PART
OF A COMPLETE PACKAGE WITHIN THE DEFINITIONS OF ORDINARY INDUSTRY
STANDARDS. ALL TRADES ARE RESPONSIBLE FOR REVIEWING THE ENTIRE SET
OF DRAWINGS THEREBY NOTING AND INCLUDING THEIR WORK AS APPLICABLE.
THE INTENT OF THE DRAWING SET IS TO RESULT IN A COMPLETE AND FINISHED
PROJECT IN ALL REGARDS AT THE CONCLUSION OF THE WORK. INCLUDE ALL
WORK, WHETHER SHOWN OR NOT, AS MAY BE NECESSARY TO ACCOMPLISH THE
INTENDED RESULT.
3. APPLY AND PAY FOR ALL PERMITS, INSPECTIONS, APPROVALS, ETC. ARRANGE
AND COORDINATE ALL REQUIRED INSPECTIONS AND SECURE ALL NECESSARY
APPROVALS OF THE WORK.
4. BECOME FAMILIAR WITH THE PROJECT THROUGH INSPECTION OF THE SITE AND
REVIEW OF THE DRAWINGS SO AS TO THOROUGHLY UNDERSTAND THE NATURE
AND REQUIREMENTS OF THE WORK. ANY AND ALL DISCREPANCIES OR
OMISSIONS TO BE REPORTED TO THE OWNER PRIOR TO THE COMMENCEMENT OF
ANY WORK AFFECTED BY SUCH DISCREPANCY OR OMISSION. ENSURE THAT
DISCREPANCIES OR OMISSIONS ARE REPORTED AND CLARIFICATION OBTAINED
PRIOR TO WORK BEING PERFORMED. ANY AND ALL WORK PROCEEDING
OTHERWISE AND THEN FOUND TO BE INCORRECT OR INCONSISTENT WITH THE
INTENDED RESULT WILL BE REMOVED, REPLACED AND/OR CORRECTED BY THE
CONTRACTOR AT NO ADDITIONAL COST OR BURDEN TO THE OWNER. VERIFY ALL
DIMENSIONS AND LOCATIONS IN THE FIELD. COORDINATE ALL WORK WITH
CONDITIONS ENCOUNTERED IN THE FIELD AND MAKE ALL NECESSARY
ADJUSTMENTS ACCORDINGLY.
5. CONTRACTOR IS RESPONSIBLE FOR FINAL FIT, FINISH, APPEARANCE AND
PERFORMANCE OF ALL WORK.
6. VERIFY ALL DIMENSIONS AND CONDITIONS AT THE WORK SITE PRIOR TO THE
COMMENCEMENT OF WORK.
7. VERIFY EXISTING CONDITIONS AFFECTING THE WORK PRIOR TO BIDDING AND ALL
ASPECTS OF THE WORK PRIOR TO COMMENCEMENT.
8. APPLY, INSTALL OR UTILIZE ALL MATERIALS IN ACCORDANCE WITH
MANUFACTURER’S PRINTED LITERATURE.
9. ALL WORK TO BE PERFORMED IN A FIRST-CLASS WORKMANLIKE MANNER,
MATCHING AND ALIGNING ALL SURFACES SO AS TO AFFORD A NEAT FINISHED
APPEARANCE. CLEAN ALL SURFACES FREE OF SOIL, DIRT, REFUSE AND DEBRIS
RESULTANT FROM THE WORK. ALL ADJACENT SURFACES TO BE LEFT AS THEY
APPEARED PRIOR TO COMMENCEMENT OF THE WORK. PROVIDE ADEQUATE
PROTECTION OF ALL ADJACENT AND EXISTING SURFACES TO REMAIN SUFFICIENT
TO ENSURE AGAINST DAMAGE DURING CONSTRUCTION OPERATIONS. AT
CONCLUSION OF THE WORK, ALL FINISHED EXPOSED SURFACES INCLUDING
GLASS, ALUMINUM AND FINISHED HARDWARE TO BE THOROUGHLY CLEANED TO
THE SATISFACTION OF THE OWNER.
10. ALL WORK TO BE PROPERLY AND ADEQUATELY PROTECTED FROM DAMAGE AT
ALL TIMES REGARDLESS OF THE STAGE OF COMPLETION. TAKE RESPONSIBILITY
FOR SAFETY AT ALL TIMES, IN ALL PLACES AND UNDER ALL CONDITIONS
AFFECTING OR AFFECTED BY THE WORK. ADHERE TO ALL ACCEPTED SAFETY
PRACTICES AND PROVIDE ALL FENCES, BARRICADES, GUARDRAILS, PARTITIONS,
ETC. AS MAY BE NECESSARY IN ORDER TO PROTECT LIFE AND PROPERTY FROM
INJURY OR DAMAGE AND AS MAY BE REQUIRED BY ANY AND ALL AUTHORITIES
HAVING JURISDICTION. REPAIR ANY AND ALL DAMAGE TO THE PREMISES ARISING
FROM OR ASSOCIATED WITH WORK SITE OPERATIONS AND/OR ACTIVITIES
CONNECTED TO THE WORK.
11. LEAVE ALL CHASES, HOLES, OPENINGS, ETC. PLUMB LEVEL, TRUE AND OF A
PROPER SIZE OR CUT SAME INTO EXISTING WORK AS MAY BE NECESSARY FOR
PROPER INSTALLATION OF WORK. CONSULT, CONFER AND OTHERWISE
COORDINATE WITH ANY AND ALL OTHER CONTRACTORS AND CONCERNED
PARTIES REGARDING PROPER LOCATION, SIZE, PLACEMENT, ALIGNMENT AND
ORIENTATION OF SAME. IN CASE OF ANY FAILURE TO LEAVE OR CUT SUCH
OPENINGS OR OTHERWISE LEAVE SUCH ACCOMMODATIONS IN PROPER PLACE,
CUT THEM AFTERWARDS AT OWN EXPENSE. NO EXCESSIVE CUTTING WILL BE
PERMITTED NOR ANY STRUCTURAL MEMBERS TO BE CUT WITHOUT THE CONSENT
OF THE ARCHITECT.
12. ALL EQUIPMENT TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. ALL LABOR, EQUIPMENT AND MATERIAL TO BE
GUARANTEED AS PER PROJECT SPECIFICATIONS.
13. COMPLY WITH ALL OWNER SAFETY TRAINING REQUIREMENTS AND SITE
PROCEDURES, AND COORDINATE THE FOREGOING WITH OWNER'S DESIGNATED
REPRESENTATIVES.
14. PERFORM ALL WORK WITHOUT INTERFERING WITH OWNER'S NORMAL
OPERATIONS.
15. PROJECT DOCUMENTS ARE INTENDED TO BE COMPLEMENTARY. ITEMS
INDICATED IN ONE PLACE OR ANOTHER AMONG THE DOCUMENTS ARE INTENDED
AS THOUGH SHOWN IN ALL PLACES.
16. COORDINATE ALL NEW WORK WITH ALL EXISTING CONDITIONS. EXISTING
ELEMENTS AFFECTING THE WORK REQUIRE SUCH COORDINATION WHETHER OR
NOT THEY ARE INDICATED IN THE DOCUMENTS.
17. DO NOT SCALE DRAWINGS FOR CONSTRUCTION PURPOSES.
18. GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF
SUBSTANTIAL COMPLETION.
1. UNOBSTRUCTED ACCESS TO EXISTING EMERGENCY EXISTS SHALL BE
MAINTAINED AT ALL TIMES.
2. ALL DEBRIS AND UNUSED MATERIAL RESULTING FROM DEMOLITION SHALL BE
DISPOSED OF OFF SITE IN COMPLIANCE WITH ALL LOCAL, STATE, AND FEDERAL
AUTHORITIES.
3. REMOVE EXISTING PARTITIONS, EQUIPMENT, & DEVICES AS INDICATED.
4. REMOVAL OF EXISTING HVAC & PLUMBING FIXTURES & SAFING TO BE BY
APPROPRIATE TRADES.
5. COORDINATE LOCATION OF ALL NEW FLOOR & WALL PENETRATIONS WITH OWNER
PRIOR TO CUTTING OR CORING. COORDINATE LOCATION WITH CONSTRUCTION
DRAWINGS. SEAL ALL PENETRATIONS.
6. ALL CONTRACTORS ARE TO REPORT ALL UNEXPECTED, UNCOVERED EXISTING
CONDITIONS WHICH IMPACT LAYOUT OF NEW WORK IMMEDIATELY TO ARCHITECT.
7. FOR EXTENT & SCOPE OF PLUMBING, MECHANICAL & ELECTRICAL REMOVALS, SEE
INDIVIDUAL TRADE DRAWINGS.
8. SAW CUT ALL NEW OPENINGS IN EXISTING CONSTRUCTION. DO NOT HAMMER &
CHISEL. CARE MUST BE TAKEN NOT TO DAMAGE EXISTING CONSTRUCTION.
COORDINATE TIME OF LOUD/HEAVY NOISE CONSTRUCTION WITH OWNER TO LIMIT
DISTURBANCE.
9. PROVIDE PORTABLE LIGHTING DURING DEMOLITION & CONSTRUCTION AS
REQUIRED.
10. PROVIDE DUMPSTERS AND OTHER DEMOLITION EQUIPMENT AS REQUIRED.
11. REMOVE EXISTING WORK AS REQUIRED TO ACCOMMODATE NEW WORK,
INCLUDING EXISTING WALL & FLOOR FINISHES IN SPACES SCHEDULED TO BE
REFINISHED.
12. PROVIDE APPROPRIATE FULL HEIGHT PROTECTION/TEMPORARY PARTITIONS
PRIOR TO COMMENCING DEMOLITION. PLACED IN LOCATIONS APPROVED BY
OWNER.
13. ALL BUILDING ACCESS AND REMOVAL OF MATERIALS MUST BE APPROVED BY
OWNER.
14. FOR EXTENT & SCOPE OF ALL AREAS OF EXISTING CONSTRUCTION TO BE
INSPETED IN THE FIELD. ALL DETERIORATED MEMBERS OR MEMBERS THAT
CONTAIN BLACK MOLD SHALL BE REMOVED. BLACK MOLD SHALL BE REMOVED IN
ACCORDANCE WITH THE REQUIREMENTS OF OSHA, EPA GUIDELINES, AND THE
NEW HAMPSHIRE DEPARTMENT OF HEALTH AND HUMAN SERVICES, AND THAT
DEMOLITION CONTRACTOR SHALL BE CERTIFIED PER NEW HAMPSHIRE'S MOLD
ASSESSMENT AND REMEDIATION CERTIFICATION LAW AND PROVIDE
DOCUMENTATION OF THE REMEDIATION PROCESS AND VERIFY THAT THE AREA IS
DRY AND FREE OF MOLD CONTAMINATION.
ABV ABOVE
AC AIR CONDITIONING
ACST ACOUSTIC
ADDL ADDITIONAL
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AGGR AGGREGATE
AL ALUMINUM
ALT ALTERNATE
ARCH ARCHITECTURAL
ASB ASBESTOS
ASPH ASPHALT
ASSN ASSOCIATION
ASST ASSISTANT
ASSY ASSEMBLY
ATOR ABOVE TOP OF RAIL
AVE AVENUE
AVG AVERAGE
B BOTTOM
BALC BALCONY
BD BOARD
BETW BETWEEN
BLDG BUILDING
BLKG BLOCKING
BLR BOILER
BM BEAM
BM BENCHMARK
BP BASE PLATE
BRDG BRIDGING
BRG BEARING
BS BOTH SIDES
BSMT BASEMENT
CAB CABINET
CAP CAPACITY
CDR COILING DOOR
CER CERAMIC
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CFGI CONTRACTOR FURNISHED,
GOVERNMENT INSTALLED
CI CAST IRON
CIP CAST IRON PIPE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CMIU CONCRETE MASONRY
INSULATED UNIT
CMU CONCRETE MASONRY UNIT
CNCL CONCEALED
CO CLEANOUT
CO COMPANY
COL COLUMN
COMP COMPOSITION
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CPT CARPET
CRV CURVED
CSK COUNTERSINK/COUNTERSUNK
CTD COATED
CTR CENTER
CUH CABINET UNIT HEATER
D DEPTH
DBL DOUBLE
DEG DEGREE
DEP DEPARTMENT
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DL DEAD LOAD
DMPF DAMPPROOFING
DN DOWN
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
E EAST
E.G. FOR EXAMPLE
EA EACH
EF EXHAUST FAN
EGEN EMERGENCY GENERATOR
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
ENTR ENTRANCE
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FAB FABRICATE
FBD FIBERBOARD
FD FLOOR DRAIN
FDN FOUNDATION
FDR FIRE DOOR
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHY FIRE HYDRANT
FIN FINISH
FL FLASHING
FLEX FLEXIBLE
FLG FLANGE
FLR FLOOR
FLRG FLOORING
FP FIREPROOF
FRP FIBER-REINFORCED PLASTIC
FRT FIRE RETARDANT TREATED
FTG FOOTING
FURN FURNITURE
GA GAUGE / GAGE
GALV GALVANIZED
GEN GENERATOR
GFCI GOVERNMENT FURNISHED,
CONTRACTOR INSTALLED
GFGI GOVERNMENT FURNISHED,
GOVERNMENT INSTALLED
GL GLASS
GLU-LAM GLUE-LAMINATED
GOVT GOVERNMENT
GR GRADE
GRD GROUND
GVL GRAVEL
GYP GYPSUM
H HIGH
HDWE HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HPT HIGH POINT
HT HEIGHT
HTR HEATER
HVAC HEATING, VENTILATION
AND AIR CONDITIONING
I.E. THAT IS
ICF INSULATED CONCRETE FORM
ID INSIDE DIAMETER
IH INTAKE HOOD
INSUL INSULATED
INTR INTERIOR
JST JOIST
JT JOINT
L LONG
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LG LENGTH
LH LEFT HAND
LIB LIBRARY
LIN LINEAR
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
LT LIGHT
LWC LIGHTWEIGHT CONCRETE
M METER
MAINT MAINTENANCE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MEZZ MEZZANINE
MFR MANUFACTURER
MGR MANAGER
MH MANHOLE
MIL MILITARY
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOLDING
MM MILLIMETER
MO MASONRY OPENING
MOD MOTOR OPERATED DAMPER
MTG MOUNTING
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NRC NOISE-REDUCTION COEFFICIENT
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OPPOSITE HAND
OHC OVERHEAD COILING DOOR
OHDR OVERHEAD DOOR
OHS OVERHEAD SECTIONAL DOOR
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND BOARD
P/L PROPERTY LINE
PASS PASSENGER
PERF PERFORATED
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
PORC PORCELAIN
PR PAIR
PREFAB PREFABRICATED
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTD PAINTED
PTN PARTITION
PVC POLYVINYL CHLORIDE
QTF QUARRY TILE FLOOR
R RADIUS
R RISER
RD ROOF DRAIN
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE
REQD REQUIRED
RET RETURN
REV REVISION
RFG ROOFING
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
RWC RAIN WATER CONDUCTOR
S SOUTH
SAPC SUSPENDED ACOUSTICAL PANEL
CEILING
SCHED SCHEDULE
SDG SIDING
SEC SECTION
SF SQUARE FOOT
SGFT STRUCTURAL GLAZED FACING
TILE
SH SHOWER
SHM SECURITY HOLLOW METAL
SHT SHEET
SI INTERNATIONAL SYSTEM OF
UNITS
SIM SIMILAR
SKY SKYLIGHT
SLDR SLIDING DOOR
SMLS SEAMLESS
SPA SPACING
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
STWY STAIRWAY
SUPT SUPERINTENDENT
SUPVR SUPERVISOR
SURF SURFACE
SUSP SUSPENDED / SUSPENSION
SYS SYSTEM
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T/ TOP OF
TAN TANGENT
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
THRU THROUGH
TLT TOILET
TRTD TREATED
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VTR VERTICAL
W WEST
W WIDE
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WCLE WHEELCHAIR LIFT ENCLOSURE
WD WOOD
WTRPRF WATERPROOFING
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
AS APPLICABLE.
NEW HAMPSHIRE CODES IN FORCE:
2018 INTERNATIONAL BUILDING CODE WITH NH AMENDMENTS
2018 INTERNATIONAL RESIDENTIAL CODE WITH NH AMENDMENTS
2018 INTERNATIONAL EXISTING BUILDING CODE WITH NH AMENDMENTS
2021 NEW HAMPSHITE STATE FIRE CODE; NFPA 1 AND NFPA 101
2021 INTERNATIONAL PLUMBING CODE WITH NH AMENDMENTS
2021 INTERNATIONAL MECHANICAL CODE WITH NH AMENDMENTS
2018 INTERNATIONAL ENERGY CONSERVATION CODE WITH NH AMENDMENTS
2020 NATIONAL ELECTRICAL CODE WITH NH AMENDMENTS
2010 ADA STANDARDS; 2009 ICCA117.1 AND FHA/UFAS AS APPLICABLE
2018 IRC
2018 IBC & IEBC CODE ANALYSIS:
BUILDING CODE INFORMATION SUMMARY, PITTSBURG, NH
CHAPTER 9 - ROOF ASSEMBLIES
THE PROVISIONS OF THIS CHAPTER SHALL GOVERN THE DESIGN, MATERIALS, CONSTRUCTION AND
QUALITY OF ROOF ASSEMBLIES.
R908.1 GENERAL
MATERIALS AND METHODS OF APPLICATION USED FOR RECOVERING OR REPLACING AN EXISTING
ROOF COVERING SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 9.
EXCEPTIONS:
2. FOR ROOFS THAT PROVIDE POSITIVE DRAINAGE, RECOVERING OR REPLACING AN EXISTING ROOF
COVERING SHALL NOT REQUIRE THE SECONDARY (EMERGENCY OVERFLOW) DRAINS OR
SCUPPERS OF SECTION R903.4.1 TO BE ADDED TO AN EXISTING ROOF.
R908.3 ROOF REPLACEMENT
ROOF REPLACEMENT SHALL INCLUDE THE REMOVAL OF EXISTING LAYERS OF ROOF COVERINGS
DOWN TO THE ROOF DECK.
EXCEPTION: WHERE THE EXISTING ROOF ASSEMBLY INCLUDES AN ICE BARRIER MEMBRANE THAT IS ADHERED TO THE ROOF DECK, THE EXISTING ICE BARRIER MEMBRANE SHALL BE PERMITTED TO
REMAIN IN PLACE AND COVERED WITH AN ADDITIONAL LAYER OF ICE BARRIER MEMBRANE IN
ACCORDANCE WITH SECTION R905.
CHAPTER 10 - CHIMNEYS AND FIREPLACES
R1003.9.1 CHIMNEY CAPS
MASONRY CHIMNEYS SHALL HAVE A CONCRETE, METAL OR STONE CAP, A DRIP EDGE AND A
CAULKED BOND BREAK AROUND ANY FLUE LINERS IN ACCORDANCE WITH ASTM C1283. THE
CONCRETE, METAL OR STONE CAP SHALL BE SLOPED TO SHED WATER.
CHAPTER 11 - ENERGY EFFICIENCY
N1109.1.1 (R503.1.1) BUILDING ENVELOPE
BUILDING ENVELOPE ASSEMBLIES THAT ARE PART OF THE ALTERATION SHALL COMPLY WITH SECTION N1102.1.2 OR N1102.1.4, SECTIONS N1102.2.1 THROUGH N1102.2.13, N1102.3.1, N1102.3.2, N1102.4.3 AND N1102.4.5.
EXCEPTION: THE FOLLOWING ALTERATIONS SHALL NOT BE REQUIRED TO COMPLY WITH THE REQUIREMENTS FOR NEW CONSTRUCTION PROVIDED THAT THE ENERGY USE OF THE BUILDING IS NOT INCREASED:
1. STORM WINDOWS INSTALLED OVER EXISTING FENESTRATION.
2. EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURING CONSTRUCTION PROVIDED THAT THESE
CAVITIES ARE FILLED WITH INSULATION.
3. CONSTRUCTION WHERE THE EXISTING ROOF, WALL OR FLOOR CAVITY IS NOT EXPOSED.
4. ROOF RECOVER.
5. ROOFS WITHOUT INSULATION IN THE CAVITY AND WHERE THE SHEATHING OR INSULATION IS EXPOSED
DURING REROOFING SHALL BE INSULATED EITHER ABOVE OR BELOW THE SHEATHING.
6. SURFACE-APPLIED WINDOW FILM INSTALLED ON EXISTING SINGLE-PANE FENESTRATION ASSEMBLIES TO
REDUCE SOLAR HEAT GAIN PROVIDED THAT THE CODE DOES NOT REQUIRE THE GLAZING OR
FENESTRATION ASSEMBLY TO BE REPLACED.
SCOPE OF WORK:
REPAIR AND/OR REPLACEMENT OF EXISTING ROOF SHINGLES, WEATHER BARRIER AND SHEATHING.
REPAIR AND/OR REPLACEMENT OF EXISTING WOOD FASCIA, ROOF SOFFIT, TRIM AND FLASHING.
CHIMNEY REPOINTING AND FLASHING.
CLASSIFICATION OF WORK:
ALTERATION: LEVEL 1
MATERIALS LEGEND
SYMBOLS LEGEND
1 2 3 4 5 6
A
B
C
D
E
PROJECT NUMBER:
DESIGNED: MODELED: CHECKED:
DATE:
DRAWING TITLE:
DRAWING NO.:
1 2 3 4 5 6
L o c a l F ile
Gannett Fleming Architects, Inc.
207 Senate Avenue Camp Hill • PA • 17011 t 717 • 763 • 7211 www.gannettfleming.com
/8 /2
:0
:5
P
M
A u to d e s k D o c s
/0
N
H D
E S
L a k e p o rt D a m
T e n d e r H o u s e /0
A M u rp h y c e n tr a l_
R
.r v t
A001
11/08/2024
MJSGIKGIK
073685
M U
R P
H Y
D A
M T
E N
D E
R R
O O
F R
E P
L A
C E
M E
N T
N H
D E
S
-4
M
U R
P H
Y D
A M
R D
P
IT
T
S B
U R
G
N H
BID SET
C e n tr a l F ile B
IM
A
R
.r v t
P ro je c t N u m b e r:
GENERAL NOTES,
SYMBOLS, LEGENDS &
ABBREVIATIONS
ARCHITECTURAL
GENERAL NOTESGENERAL DEMOLITION NOTESABBREVIATIONS
REVISIONS
NO. DATE DESCRIPTION
1. MASONRY DIMENSIONS ARE NOMINAL UNLESS NOTED OTHERWISE.
2. DIMENSIONS AT CMU WALLS ARE TO THE FACE OF CMU UNLESS NOTED
OTHERWISE.
3. DIMENSIONS AT INTERIOR STUD WALLS ARE TO THE CENTERLINE OF STUD
UNLESS NOTED OTHERWISE.
4. DIMENSIONS AT EXTERIOR STUD WALLS ARE TO THE INSIDE FACE OF STUD
UNLESS NOTED OTHERWISE.
5. DIMENSIONS FOLLOWED BY AN ASTERISK (*) ARE TO THE FACE OF STUD ON ONE
OR BOTH SIDES.
31'-10"29'-0"
23'-10"
10'-2"
8'-10"
A1 A2
A3
A
A
A1 A2 A1 A2
A
A
38'-11"
A1 A2
A1 A2
A
A
A4
A
A4
A4
30'-11"
A
A
A1 A2 A4
A301
A301
Sim
A301
Sim
A301
Sim
A301
Sim
A301
Sim
A301
Sim
A301
A1 A2A8
A8
A8
A8 A7 A7A7
A7
A7A7A7
A7
A7
A7 A7
2"
1. ALL ROOFING TO RECEIVE FINAL APPROVAL FROM OWNER UNLESS NOTED
OTHERWISE.
2. ALL ROOF SLOPES ARE EXISTING UNLESS NOTED OTHERWISE.
3. RIGID INSULATION, MINIMUM TWO LAYERS WITH STAGGERED JOINTS.
4. ALL GUTTERS ARE 5"x5" STYLE "K" UNLESS NOTED OTHERWISE.
5. ALL DOWNSPOUTS ARE 3"x4" UNLESS NOTED OTHERWISE.
6. SEE STRUCTURAL DRAWINGS FOR TRUSS AND JOIST BEARING ELEVATIONS.
7. VERIFY SIZE AND LOCATION OF ALL EQUIPMENT.
8. SEE MECHANICAL DRAWINGS FOR ROOF PENETRATIONS SUCH AS VENT PIPES
AND EXHAUST FANS.
9. PROVIDE CRICKETS AT THE UPSLOPE SIDE OF ALL ROOF MOUNTED EQUIPMENT.
10. SEE ELECTRICAL DRAWINGS FOR LOCATIONS OF GOOSENECK PIPE
PENETRATIONS.
11. ALL PLYWOOD AND BLOCKING ASSOCIATED WITH THE ROOF CONSTRUCTION
SHALL BE FIRE RETARDANT TREATED.
31'-10"29'-0"
23'-10"
38'-11"
10'-2"
8'-10"
D1 D2
D1 D2
D
D
D1 D2
D1 D2
D
D
D
D
D5
D
D1 D2
D3
D4
D
1 2 3 4 5 6
A
B
C
D
E
PROJECT NUMBER:
DESIGNED: MODELED: CHECKED:
DATE:
DRAWING TITLE:
DRAWING NO.:
1 2 3 4 5 6
L o c a l F ile
Gannett Fleming Architects, Inc.
207 Senate Avenue Camp Hill • PA • 17011 t 717 • 763 • 7211 www.gannettfleming.com
/8 /2
:0
:5
P
M
A u to d e s k D o c s
/0
N
H D
E S
L a k e p o rt D a m
T e n d e r H o u s e /0
A M u rp h y c e n tr a l_
R
.r v t
A101
11/08/2024
MJSGIKGIK
073685
M U
R P
H Y
D A
M T
E N
D E
R R
O O
F R
E P
L A
C E
M E
N T
N H
D E
S
-4
M
U R
P H
Y D
A M
R D
P
IT
T
S B
U R
G
N H
BID SET
C e n tr a l F ile B
IM
A
R
.r v t
P ro je c t N u m b e r:
5 PLANS
ARCHITECTURAL
FLOOR PLAN NOTES
ROOF NOTES
REVISIONS
NO. DATE DESCRIPTION
SCALE: 1/8" = 1'-0"
ROOF PLAN
SCALE: 1/8" = 1'-0"
ROOF DEMOLITION PLAN
KEYNOTE LEGEND
A1 REPAIR OR REPLACE EXISTING PLYWOOD
SUBSTRATE AS REQUIRED. PROVIDE 30 MIL MINIMUM
ICE & WATER SHIELD UNDERLAYMENT AND EXTEND
NOT LESS THAN 3'-0" FROM THE LOWEST EDGES OF
ALL ROOF SURFACES.
A2 NEW ASPHALT ROOF SHINGLES. OWNER TO APPROVE
SELECTION PRIOR TO INSTALLATION.
A3 REPOINT CHIMNEY AND PROVIDE NEW CHIMNEY CAP
AS REQUIRED PER IRC R1003.9.1. SEE SHEET A001.
A4 PROVIDE NEW GUTTER, DOWNSPOUT AND SPLASH
PAD. DRAIN TO DAYLIGHT.
A7 NEW LIGHTING PROTECTION SYSTEM
A8 OUTLINE OF EXTERIOR WALL BELOW
D1 REMOVE EXISTING DRIP EDGES AT ALL ROOF
SURFACES
D2 REMOVE EXISTING ASPHALT SHINGLES AND ROOF
MEMBRANE AT ALL ROOF SURFACES
D3 SAW CUT EXISTING CHIMNEY BRICK JOINTS AND
PREP FOR REPOINTING.
D4 REMOVE AND REPLACE EXISTING GUTTER AND
DOWNSPOUT
D5 REMOVE EXISTING METAL ROOF AT ALL ROOF
SURFACES
1. MATTE FACE MASONRY SHALL BE USED AT ALL WALL MOUNTED LIGHT FIXTURES,
COPINGS, AND OTHER WALL MOUNTED EQUIPMENT. COLOR TO MATCH ADJACENT
MASONRY.
2. ENSURE SIZE AND LOCATIONS OF MASONRY WALL OPENINGS ARE COORDINATED
WITH THE INSULATED CONCRETE FORMS.
3. ALL GUTTERS AND DOWNSPOUTS TO MATCH FASCIA COLORS.
GROUND FLOOR
0' - 0"
GROUND FLOOR
0' - 0"
SECOND FLOOR
9' - 0"
SECOND FLOOR
9' - 0"
BASEMENT
-8' - 0"
BASEMENT
-8' - 0"
ATTIC
18' - 1 5/16"
ATTIC
18' - 1 5/16"
T.O. ROOF
28' - 0"
T.O. ROOF
28' - 0"
A2A5 A3 A5 A2 A4A5A2 A5A7 A7A7 A7 A7A2A4 A7 A7 A7
GROUND FLOOR
0' - 0"
GROUND FLOOR
0' - 0"
SECOND FLOOR
9' - 0"
SECOND FLOOR
9' - 0"
BASEMENT
-8' - 0"
BASEMENT
-8' - 0"
ATTIC
18' - 1 5/16"
ATTIC
18' - 1 5/16"
T.O. ROOF
28' - 0"
T.O. ROOF
28' - 0"
A7 A2 A7 A3 A7
A2
A2
A2A2
A4
A7
GROUND FLOOR
0' - 0"
GROUND FLOOR
0' - 0"
SECOND FLOOR
9' - 0"
SECOND FLOOR
9' - 0"
BASEMENT
-8' - 0"
BASEMENT
-8' - 0"
ATTIC
18' - 1 5/16"
ATTIC
18' - 1 5/16"
T.O. ROOF
28' - 0"
T.O. ROOF
28' - 0"
A7A2A7 A5A7A2 A7A4A2 A5A4
A2
A5
A3A5
GROUND FLOOR
0' - 0"
GROUND FLOOR
0' - 0"
SECOND FLOOR
9' - 0"
SECOND FLOOR
9' - 0"
BASEMENT
-8' - 0"
BASEMENT
-8' - 0"
ATTIC
18' - 1 5/16"
ATTIC
18' - 1 5/16"
T.O. ROOF
28' - 0"
T.O. ROOF
28' - 0"
A2A7 A7 A7A5
A2 A2
A4
1 2 3 4 5 6
A
B
C
D
E
PROJECT NUMBER:
DESIGNED: MODELED: CHECKED:
DATE:
DRAWING TITLE:
DRAWING NO.:
1 2 3 4 5 6
L o c a l F ile
Gannett Fleming Architects, Inc.
207 Senate Avenue Camp Hill • PA • 17011 t 717 • 763 • 7211 www.gannettfleming.com
/8 /2
:0
:0
P
M
A u to d e s k D o c s
/0
N
H D
E S
L a k e p o rt D a m
T e n d e r H o u s e /0
A M u rp h y c e n tr a l_
R
.r v t
A201
11/08/2024
CheckerGIKGIK
073685
M U
R P
H Y
D A
M T
E N
D E
R R
O O
F R
E P
L A
C E
M E
N T
N H
D E
S
-4
M
U R
P H
Y D
A M
R D
P
IT
T
S B
U R
G
N H
BID SET
C e n tr a l F ile B
IM
A
R
.r v t
P ro je c t N u m b e r:
5 ELEVATIONS
ARCHITECTURAL
ELEVATION NOTES
REVISIONS
NO. DATE DESCRIPTION
SCALE: 1/8" = 1'-0"
SOUTH ELEVATION
SCALE: 1/8" = 1'-0"
EAST ELEVATION
SCALE: 1/8" = 1'-0"
NORTH ELEVATION
SCALE: 1/8" = 1'-0"
WEST ELEVATION
KEYNOTE LEGEND
A2 NEW ASPHALT ROOF SHINGLES. OWNER TO APPROVE
SELECTION PRIOR TO INSTALLATION.
A3 REPOINT CHIMNEY AND PROVIDE NEW CHIMNEY CAP
AS REQUIRED PER IRC R1003.9.1. SEE SHEET A001.
A4 PROVIDE NEW GUTTER, DOWNSPOUT AND SPLASH
PAD. DRAIN TO DAYLIGHT.
A5 V.I.F. FASCIA AND BLOCKING FOR DETERIORATION.
REPAIR/ REPLACE AS NEEDED.
A7 NEW LIGHTING PROTECTION SYSTEM
ALL EXISTING PLYWOOD AND BLOCKING ASSOCIATED WITH
THE ROOF CONSTRUCTION SHALL BE INSPECTED IN FIELD FOR
DETERIORATION AND/OR THE PRESENCE OF BLACK MOLD AND
ARE TO BE REPAIRED AN/OR REPLACED AS REQUIRED.
NEW FLASHING AS REQUIRED.
NEW ASPHALT SHINGLE ROOF WITH NEW WEATHER BARRIER.
PROVIDE 30 MIL MINIMUM ICE & WATER SHIELD UNDERLAYMENT.
ALL EXISTING ROOF RAFTERS ASSOCIATED WITH
THE ROOF CONSTRUCTION SHALL BE INSPECTED IN
FIELD FOR DETERIORATION AND ARE TO BE
REPAIRED AND/OR REPLACED AS REQUIRED.
NEW DRIP EDGE. INSPECT EXISTING BLOCKING IN FIELD FOR
DETERIORATION. REPLACE WITH NEW BLOCKING AS REQUIRED.
ALL EXISTING WOOD SOFFITS ASSOCIATED WITH THE ROOF
CONSTRUCTION SHALL BE INSPECTED IN FIELD FOR
DETERIORATION AND ARE TO BE REPAIRED AND/OR REPLACED.
PROVIDE NEW SOFFIT VENTS @ 5'-0" O.C. AS REQUIRED.
NEW ASPHALT SHINGLE ROOF WITH NEW WEATHER BARRIER.
PROVIDE 30 MIL MINIMUM ICE & WATER SHIELD UNDERLAYMENT
AND EXTEND NOT LESS THAN 3'-0" FROM THE LOWEST EDGES
OF ALL ROOF SURFACES.
ALL EXISTING ROOF RAFTERS ASSOCIATED WITH THE ROOF
CONSTRUCTION SHALL BE INSPECTED IN FIELD FOR DETERIORATION
AND ARE TO BE REPAIRED AND/OR REPLACED AS REQUIRED.
EXISTING EXTERIOR WALL
ALL EXISTING PLYWOOD AND BLOCKING ASSOCIATED WITH THE ROOF
CONSTRUCTION SHALL BE INSPECTED IN FIELD FOR DETERIORATION
AND/OR THE PRESENCE OF BLACK MOLD AND ARE TO BE REPAIRED
AN/OR REPLACED AS REQUIRED.
M
IN
/2
PATCH AND REPAIR
EXISTING CHIMNEY CAP
PROVIDE NEW STAINLESS STEEL
SPARK ARRESTOR AND CAP PER
CODE. SEE SHEET A001.
EXISTING CHIMNEY BRICK INFILL IS TO BE
INSPECTED IN FIELD FOR DETIORIORATION. PATCH,
REPAIR AND REPOINT BRICKS AS REQUIRED.
PROVIDE NEW STEP FLASHING,
COUNTERFLASHING AND SEALANT
AT ROOF
NEW ASPHALT SHINGLE ROOF OVER
EXISTING ROOF STRUCTURE
M
IN
GROUND FLOOR
0' - 0"
GROUND FLOOR
0' - 0"
SECOND FLOOR
9' - 0"
SECOND FLOOR
9' - 0"
BASEMENT
-8' - 0"
BASEMENT
-8' - 0"
ATTIC
18' - 1 5/16"
ATTIC
18' - 1 5/16"
T.O. ROOF
28' - 0"
T.O. ROOF
28' - 0"
A301
Sim
A301
Sim
A301
Sim
ALL EXISTING PLYWOOD AND BLOCKING ASSOCIATED WITH THE
ROOF CONSTRUCTION SHALL BE INSPECTED IN FIELD FOR
DETERIORATION AND/OR THE PRESENCE OF BLACK MOLD AND
ARE TO BE REPAIRED AN/OR REPLACED AS REQUIRED.
ALL EXISTING ROOF RAFTERS ASSOCIATED WITH
THE ROOF CONSTRUCTION SHALL BE INSPECTED IN
FIELD FOR DETERIORATION AND ARE TO BE
REPAIRED AND/OR REPLACED AS REQUIRED.
NEW GUTTER. INSPECT EXISTING WOOD BLOCKING AND
FASCIA IN FIELD FOR DETERIORATION. REPLACE WITH NEW
PRIOR TO GUTTER INSTALLATION AS REQUIRED.
NEW DRIP EDGE. INSPECT EXISTING BLOCKING IN FIELD FOR
DETERIORATION. REPLACE WITH NEW BLOCKING AS REQUIRED.
ALL EXISTING WOOD SOFFITS ASSOCIATED WITH THE ROOF
CONSTRUCTION SHALL BE INSPECTED IN FIELD FOR
DETERIORATION AND ARE TO BE REPAIRED AND/OR REPLACED.
PROVIDE NEW SOFFIT VENTS @ 5'-0" O.C. AS REQUIRED.
NEW ASPHALT SHINGLE ROOF WITH NEW WEATHER BARRIER.
PROVIDE 30 MIL MINIMUM ICE & WATER SHIELD UNDERLAYMENT
AND EXTEND NOT LESS THAN 3'-0" FROM THE LOWEST EDGES
OF ALL ROOF SURFACES.
EXISTING EXTERIOR WALL
1 2 3 4 5 6
A
B
C
D
E
PROJECT NUMBER:
DESIGNED: MODELED: CHECKED:
DATE:
DRAWING TITLE:
DRAWING NO.:
1 2 3 4 5 6
L o c a l F ile
Gannett Fleming Architects, Inc.
207 Senate Avenue Camp Hill • PA • 17011 t 717 • 763 • 7211 www.gannettfleming.com
/8 /2
:0
:0
P
M
A u to d e s k D o c s
/0
N
H D
E S
L a k e p o rt D a m
T e n d e r H o u s e /0
A M u rp h y c e n tr a l_
R
.r v t
A301
11/08/2024
MJSGIKGIK
073685
M U
R P
H Y
D A
M T
E N
D E
R R
O O
F R
E P
L A
C E
M E
N T
N H
D E
S
-4
M
U R
P H
Y D
A M
R D
P
IT
T
S B
U R
G
N H
BID SET
C e n tr a l F ile B
IM
A
R
.r v t
P ro je c t N u m b e r:
5 SECTIONS
ARCHITECTURAL
REVISIONS
NO. DATE DESCRIPTION
SCALE: 1 1/2" = 1'-0"
SECTION @ PORCH ROOF
SCALE: 1 1/2" = 1'-0"
SECTION @ CHIMNEY
SCALE: 1/8" = 1'-0"
Section 1
SCALE: 1 1/2" = 1'-0"
SECTION @ GUTTER
DAM TENDER’S HOME ROOF INSPECTION REPORT
MURPHY DAM
Coos County, New Hampshire
National Inventory of Dams ID: NH00185
New Hampshire Dam Number: D194012
Hazard Classification: High
October 2022
Murphy Dam
NID ID#: NH00185
NH Dam#: D194012
Prepared for:
The State of New Hampshire
Department of Environmental Services
29 Hazen Drive
Concord, NH 03302-0095
Prepared by:
Gannett Fleming, Inc.
207 Senate Avenue
Camp Hill, PA 17011
GF Project No. 063935.021
Dam Tender’s Home Roof Inspection i October 2022
TABLE OF CONTENTS Page
1. INTRODUCTION
1.1 Scope of Work
1.2 Facility Description
1.3 Statement of Independence
2. FIELD INSPECTION
2.1 Inspection Approach
2.2 Field Observations
3. CONCLUSIONS
4. RECOMMENDATIONS
5. APPENDICIES
APPENDICES
Appendix A Caretaker’s House at Murphy Dam Property Management Plan, February 2000
Appendix B Field Observation Map
Appendix C Observation Photolog
1 October 2022
1. INTRODUCTION
The purpose of this report is to document the dam tender’s home roof observation performed for
New Hampshire Department of Environmental Services’ (DES) Murphy Dam (hereinafter referred to as Murphy), as sanctioned by the general services contract authorized on February 12, 2018 to complete engineering services for state-owned dams and dikes in New Hampshire. This report provides a description of the dam tender’s home, the approach utilized for the field inspection, inspection observations, conclusions and recommendations.
1.1 Scope of Work
The intent of the inspection was to provide a detailed observation of the dam tender’s roof from readily accessible areas along the exterior and within the interior of the building.
Gannett Fleming mobilized a three-person inspection team to observe the condition of the roof.
During the inspection, the roof’s condition was noted with corresponding photographs.
1.2 Facility Description
Murphy is located downstream of Lake Francis along the Connecticut River east of Pittsburg, New
Hampshire. Francis Lake encompasses approximately 2000 acres and was originally constructed between 1937 and 1940 as a flood control project. The dam is currently owned by the DES and is operated primarily for the purpose of water supply, recreation, and flood control.
The facility currently utilized as the dam tender’s home was originally constructed in the mid-
1800’s. The 2-floor home rests atop a stone foundation and is attached to a two-car garage that once served as a horse barn. The front of the home exhibits a 3-season porch.
The home was originally constructed with a wood shingle roof which was replaced by asphalt shingles in the 1900’s. The roof covering as it exists today is believed to be composed of three primary types and is shown within Figure 1.:
1. 1960’s Aluminum Roofing
2. 1997 Asphalt Shingles
3. 1970’s Asphalt Shingles.
2 October 2022
Figure 1 – Roof Covering Plan View
Additional information related to the home’s construction and past maintenance can be found within the Caretaker’s House at Murphy Dam Property Management Plan, prepared by DES, dated
February 2000 and included within Appendix A.
1.3 Statement of Independence
The field inspections, review of previous facility data, conclusions, and recommendations are based upon the opinions of Gannett Fleming and were made independently from DES, its employees, and its representatives.
3 October 2022
2. FIELD INSPECTION
The roof observation took place on May 3rd of 2022.
The inspection was performed by Mr. Josh Paquet (Gannett Fleming), Mr. Don Read (Gannett
Fleming), and Mr. Scott Brough (Gannett Fleming) with assistance from DES staff.
2.1 Inspection Approach
Access to the exterior surface of the roof was by use of an extension ladder. Access to the interior of the roof within the home’s attic was via stairs within the home. Gannett Fleming did not remove roof coverings or perform any destructive observations as part of the inspection. All noted deficiencies are based on observable portions of the facility from foot or ladder.
2.2 Field Observations
The following observations correspond to the deficiency map included within Appendix B and photographic log included within Appendix C.
• OBS 1: Exposed portions of flue pipe show signs of degradation.
• OBS 2: Flashing between home and roof shingles of 3-season porch is pulling up on edge. Popped and missing nails.
• OBS 3: Paint failure along edge of fascia. Minimal rot noted.
• OBS 4: Flashing between siding on northern home section and asphalt shingles in the middle section appears to be in good condition.
• OBS 5: Start of granule loss and shingle damage (delamination, split).
• OBS 6: Complete shingle failure, granule degradation, split shingles.
• OBS 7: Two layers of shingles.
• OBS 8: One layer of shingles.
• OBS 9: Missing shingle(s).
• OBS 10: Early-stage shingle granule loss, early-stage shingle curling.
• OBS 11: Minor mortar degradation around chimney, chimney flashing nails starting to pop.
• OBS 12: Roof vent looks to be in good condition, flashing nails show early-stage corrosion.
• OBS 13: Gutters are loose, separated, cracked.
• OBS 14: Flashing exhibits popped nails.
• OBS 15: Aluminum roof generally in good condition, multi-generations of fasteners
(nails/screws), popped screws observed.
• OBS 16: Failed paint, rotted fascia.
4 October 2022
• OBS 17: Garage roof exhibits a sag at center of slope on each face (east and west). The center of the eave on each face exhibits a corresponding upward bow.
• OBS 18: Shingles show swelling most likely due to saturation as shingles extend under the siding for the garage. This has led to granule degradation and moss growth.
• OBS 19: Fascia paint failure.
• OBS 20: Siding shows signs of damage most likely due to roof runoff running along the face.
• OBS 21: The garage interior framing appears to be generally in good condition. The rafters are composed of 7.5” x 7.5” rough cut logs spaced 120” center to center. The perlins are composed of rough-cut logs, are approximately 3 ½” diameter and are spaced approximately 21 inches on center.
• OBS 22: The sheathing is composed of ¾” board and range in widths from 6 inches wide to 18 inches wide. The spacing between the sheathing boards ranges from tight to 2 inches.
• OBS 23: The bow noted within OBS 17 appears to be a result of the relatively large spans associated with the two rafters responsible for supporting the center of the roof slopes.
From the interior, bows of 1 inch to 2 inches is observed. No other structural distress or degradation within the interior framing is noted and no splitting or cracking in the bowed framing members was noted.
• OBS 24: Minor water damage, rot.
• OBS 25: The interior framing within the attic of the home appeared to be in good condition. The rafters were generally composed of 3-inch x 4-inch rough cut beams. The sheathing was composed of 7/8-inch thick, rough-cut board that ranged in width from 6 inches to 18 inches.
5 October 2022
3. CONCLUSIONS
The overall condition of the exterior of the roof is indicative of the age of the roof covering as well as the geographical location of the facility. The asphalt shingles on the northern section of the home, that were believed to be originally installed in the mid-1970’s, are in complete disrepair.
Based on the observable edges of the roof, it is believed that these sections of the roof have two layers of shingles.
The asphalt shingles in the center portion of the home, believed to be installed in the mid-1990’s, are in better condition than the northern section of the home. However, the shingles show signs of early stages of failure which include granule degradation, splitting and loosening.
The aluminum roofing over the garage is generally in good condition. The lack of structural framing has caused an observable bow on each face of the roof. Various fasteners for the aluminum roofing are replaced, popped or missing, most likely due to a combination of the deflection of the roof surface combined with a lack of fastener support provided by the sheathing which exhibited large spacings between boards.
The sag and resulting bow in the eaves of the garage roof does not appear to pose an immediate threat to the roof structure but is indicative of sustained loading within long timber spans.
6 October 2022
4. RECOMMENDATIONS
Based on the field observations described within the report above as well as review of pertinent background information, the following recommendations are provided with regards to future maintenance of the roof:
- The asphalt shingles and adjacent flashing located above the home should be replaced in their entirety with a roof covering (shingles, metal, etc.) appropriate for the geographic exposure. A contractor should be consulted as to the potential need for an additional layer of sheathing above the existing rough-cut boards as to provide continuous support for the new roof covering and its fasteners.
- The aluminum roof and adjacent flashing above the garage should be replaced in its entirety with a roof covering (shingles, metal, etc.) appropriate for the geographic exposure. A contractor should be consulted as to the potential need for an additional layer of sheathing above the existing rough-cut boards as to provide continuous support for the new roof covering and its fasteners. A contractor should also be consulted as to choosing a flexible or rigid roof covering for the garage given the curvature of the roof pitch.
7 October 2022
5. APPENDICIES
A. Caretaker’s House at Murphy Dam, Property Management Plan
B. Field Observation Map
C. Observation Photolog
Appendix A. Caretaker’s House at Murphy Dam, Property Management Plan
Appendix B. Field Observation Map jpaquet Text Box
EXTERIOR OBSERVATION MAP
jpaquet Rectangle jpaquet Callout
OBS 1 / 11
jpaquet Callout
OBS 2
jpaquet Callout
OBS 3 / 4
jpaquet Callout
OBS 5
jpaquet Callout
OBS 6
jpaquet Callout
OBS 7
jpaquet Callout
OBS 8
jpaquet Callout
OBS 9
jpaquet Ellipse jpaquet Ellipse jpaquet Callout
OBS 10
jpaquet Callout
OBS 12
jpaquet Ellipse jpaquet Callout
OBS 13
jpaquet Callout
OBS 14
jpaquet Callout
OBS 15
jpaquet PolyLine jpaquet PolyLine jpaquet PolyLine jpaquet PolyLine jpaquet Callout
OBS 16
jpaquet Callout
OBS 17
jpaquet Callout
OBS 19/20
jpaquet Callout
OBS 18
Appendix C. Observation Photolog
Appendix C
Observation Photolog
MURPHY DAM TENDER HOME ROOF INSPECTION PHOTOGRAPHS – MAY 3, 2022
Photo No. 1: Overall view of dam tender’s home, looking east.
Photo No. 2: Overall view of dam tender’s home, looking north.
Photo No. 3: Overall view of dam tender’s home, looking south.
Photo No. 4: Overall view of dam tender’s home, looking west.
Photo No. 5: Flue pipe degradation at top of chimney (OBS 1).
Photo No. 6: Flashing pulling up at edges. Popped and missing nails (OBS 2).
Photo No. 7: Paint failure along edge of fascia (OBS 3).
Photo No. 8: Flashing between siding on northern home section and asphalt shingles in the middle section appears to be in good condition (OBS 4).
Photo No. 9: Start of granule loss and shingle damage (delamination and splitting)
(OBS 5).
Photo No. 10: Complete shingle failure, granule degradation, splitting shingles (OBS 6).
Photo No. 11: Complete shingle failure, granule degradation, splitting shingles (OBS 6).
Photo No. 12: Two layers of shingles (OBS 7).
Photo No. 13: Two layers of shingles (OBS 8).
Photo No. 14: Missing shingle(s) (OBS 9).
Photo No. 15: Early-stage shingle granule loss, early-stage shingle curling (OBS 10).
Photo No. 16: Minor mortar degradation around chimney, chimney flashing nails starting to pop (OBS 11).
Photo No. 17: Roof vent looks to be in good condition, flashing nails show early-stage corrosion (OBS 12).
Photo No. 18: Gutters are loose, separated and cracked (OBS 13).
Photo No. 19: Flashing exhibits popped nails (OBS 14).
Photo No. 20: Aluminum roof generally in good condition, multi-generations of fasteners (nails/screws), popped screws observed (OBS 15).
Photo No. 21: Fascia exhibits failed paint and rotted fascia (OBS 16).
Photo No. 22: Garage roof exhibits a sag at center of slope on each face. The center of the eave on each face exhibits a corresponding upward bow (OBS 17).
Photo No. 23: Garage roof exhibits a sag at center of slope on each face. The center of
Photo No. 24: Garage roof exhibits a sag at center of slope on each face. The center of
Photo No. 25: Shingles show swelling most likely due to saturation as shingles extend under siding (OBS 18).
Photo No. 26: Fascia paint failure (OBS 19).
Photo No. 27: Siding show signs of damage most likely due to roof runoff running along face of siding (OBS 20).
Photo No. 28: Garage framing appears to be generally in good condition (OBS 21).
Photo No. 29: Sheathing is composed of ¾” board and range in widths from 6 inches wide to 18 inches wide. The spacing between the sheathing boards range from tight to 2 inches (OBS 22).
Photo No. 30: The bow noted within OBS 17 appears to be a result of the relatively large spans associated with the two rafters. 1” to 2” at the center of the rafter (OBS 23).
Photo No. 31: Minor water damage, rot (OBS 24).
Photo No. 32: Interior framing within attic of primary house appears to be in good condition (OBS 25).
| RFP Murphy Dam Tender Roof Plans and Specs 2025 |
| 2024.11.08_073685 - Murphy Roof Replacement Drawing Set |
| Sheets |
| G001 - COVER SHEET |
| A001 - GENERAL NOTES, SYMBOLS, LEGENDS & ABBREVIATIONS |
| A101 - PLANS |
| A201 - ELEVATIONS |
| A301 - SECTIONS |
2024.11.08_073685_TO 21 - NHDES Dam Tender Roof Specifications
Final Murphy Dam_Dam Tender Roof Inspection_10_24_2022
File details come from the government source that posted it. Updated .