Attachment 1 537-19-904 IFC Drawings.pdf
PDF 30 MB Posted
- Attached to
- Y1DA--537-19-904 Security Corrections - Construction Federal contract opportunity
- Solicitation number
- 36C25221B0033
About this file
This document provides details for a federal construction solicitation. The solicitation seeks bids for security door replacements and creation of a sally port configuration on the 7th floor of a bed tower at the Jesse Brown VA Medical Center in Chicago, Illinois. The project is set aside for Service-Disabled Veteran-Owned Small Businesses and has a magnitude between $2 million and $5 million. Interested contractors must be registered in the System for Award Management and listed as verified in the Vendor Information Pages database. Bids are due by November 11, 2021 for the project which has a 418 calendar day period of performance and is issued under NAICS code 236220 with a size standard of $39.5 million. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 is the contracting agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25221B0033 0008.docx | DOCX document | |
| 36C25221B0033 0007.docx | DOCX document | |
| 36C25221B0033 0006.docx | DOCX document | |
| 36C25221B0033 0005.docx | DOCX document | |
| S06 - VHA Supplemental Contract Requirements for Combatting COVID-19 Updated 12-14-2021.pdf | ||
| S06 - Revised Bid Schedule_12.22.21_537-19-904.pdf | ||
| S06 - Wage Determination_12.3.21.pdf | ||
| S06 - 537-19-904 Construction SOW rev3.pdf | ||
| 36C25221B0033 0004.docx | DOCX document | |
| 36C25221B0033 0003.docx | DOCX document | |
| 36C25221B0033 0002.docx | DOCX document | |
| 36C25221B0033 0001.docx | DOCX document | |
| Attachment 5 Exhibit2_537-19-904_Asbestos_Report.pdf | ||
| Attachment 3 537-19-904 IFC Specifications.pdf | ||
| Attachment 4 Exhibit1_537-19-904_JESSE_BROWN_SOC.pdf | ||
| Attachment 6 Wage Determination 9.10.2021.pdf | ||
| Attachment 2 537-19-904 Construction SOW Rev1.pdf | ||
| 36C25221B0033_1.docx | DOCX document |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDEX OF DRAWINGS
DRAWING TITLE
DWG NO.
G001 COVER SHEET
G002 LEGENDS, ABBREVIATIONS AND NOTES
G003 PHASING, IRCA DETAILS, LEGENDS AND NOTES
A101 FIRST FLOOR PLAN - OVERALL HOSPITAL
JESSE BROWN VA MEDICAL CENTER
ISSUED FOR BID AND CONSTRUCTION
820 South Damen Ave., Chicago, Illinios 60612
PROJECT No: 537-19-904
SECURITY CORRECTIONS
PROJECT
SITE
MAIN
HOSPITAL
DRAWING TITLE
GENERAL
ARCHITECTURAL
DWG NO.
A401 ENLARGED FLOOR PLANS - POLICE OBSERVATION ROOM & SALLYPORT
A501 MISCELLANEOUS DETAILS
A601 DOOR SCHEDULE AND DETAILS
A602 DOOR DETAILS
SECURITY
ELECTRICAL
SC001 SECURITY COVER SHEET
SC002 SECURITY EQUIPMENT SCHEDULE
SC101 HOSPITAL OVERALL BUILDING LAYOUT ACCESS CONTROL PLAN
SC400 SECURITY DOOR DETAILS
SC401 SECURITY DOOR DETAILS
SC402 SECURITY DOOR DETAILS
SC403 SECURITY DOOR DETAILS
SC500 SECURITY CAMERA DETAILS
BLDG 1 EAST
BLDG 1 WEST
BLDG 30
BLDG 40 EAST
BLDG 40 WEST
BLDG 32
BLDG 11
PHASING AND LIFE SAFETY PLANS
E000 ELECTRICAL COVER SHEET
E101 HOSPITAL OVERALL BUILDING LAYOUT ACCESS CONTROL PLAN
1-E101E BUILDING 1 - FIRST FLOOR ELECTRICAL & TECHNOLOGY PLANS EAST
1-E101W BUILDING 1 - FIRST FLOOR ELECTRICAL & TECHNOLOGY PLANS WEST
1-E102E BUILDING 1 - SECOND FLOOR ELECTRICAL & TECHNOLOGY PLANS EAST
1-E102W BUILDING 1 - SECOND FLOOR ELECTRICAL & TECHNOLOGY PLANS WEST
1-E105E BUILDING 1 - FIFTH FLOOR ELECTRICAL & TECHNOLOGY PLANS EAST
1-E105W BUILDING 1 - FIFTH FLOOR ELECTRICAL & TECHNOLOGY PLANS WEST
11-E101 BUILDING 11 - FIRST FLOOR ELECTRICAL & TECHNOLOGY PLANS
30-E101 BUILDING 30 - FIRST FLOOR ELECTRICAL & TECHNOLOGY PLANS
32-E101 BUILDING 32 - FIRST FLOOR ELECTRICAL & TECHNOLOGY PLANS
40-E101 BUILDING 40 - FIRST FLOOR ELECTRICAL & TECHNOLOGY PLANS
40-E102 BUILDING 40 - SECOND FLOOR ELECTRICAL & TECHNOLOGY PLANS
40-E104 BUILDING 40 - FOURTH FLOOR ELECTRICAL & TECHNOLOGY PLANS
40-E105 BUILDING 40 - FIFTH FLOOR ELECTRICAL & TECHNOLOGY PLANS
40-E106 BUILDING 40 - SIXTH FLOOR ELECTRICAL & TECHNOLOGY PLANS
40-E107 BUILDING 40 - SEVENTH FLOOR ELECTRICAL & TECHNOLOGY PLANS
E400 ELECTRICAL DETAILS
1-SC101E BUILDING 1 - FIRST FLOOR ACCESS CONTROL PLANS EAST
1-SC101W BUILDING 1 - FIRST FLOOR ACCESS CONTROL PLANS WEST
1-SC102E BUILDING 1 - SECOND FLOOR ACCESS CONTROL PLANS EAST
1-SC102W BUILDING 1 - SECOND FLOOR ACCESS CONTROL PLANS WEST
1-SC105E BUILDING 1 - FIFTH FLOOR ACCESS CONTROL PLANS EAST
1-SC105W BUILDING 1 - FIFTH FLOOR ACCESS CONTROL PLANS WEST
11-SC101 BUILDING 11 - FIRST FLOOR ACCESS CONTROL PLANS
30-SC101 BUILDING 30 - FIRST FLOOR ACCESS CONTROL PLANS
32-SC101 BUILDING 32 - FIRST FLOOR ACCESS CONTROL PLANS
40-SC101 BUILDING 40 - FIRST FLOOR ACCESS CONTROL PLANS
40-SC102 BUILDING 40 - SECOND FLOOR ACCESS CONTROL PLANS
40-SC104 BUILDING 40 - FOURTH FLOOR ACCESS CONTROL PLANS
40-SC105 BUILDING 40 - FIFTH FLOOR ACCESS CONTROL PLANS
40-SC106 BUILDING 40 - SIXTH FLOOR ACCESS CONTROL PLANS
40-SC107 BUILDING 40 - SEVENTH FLOOR ACCESS CONTROL PLANS
1-G101E BUILDING 1 - FIRST FLOOR PLAN - EAST - PHASING & LIFE SAFETY
1-G101W BUILDING 1 - FIRST FLOOR PLAN - WEST - PHASING & LIFE SAFETY
1-G102E BUILDING 1 - SECOND FLOOR PLAN - EAST - PHASING & LIFE SAFETY
1-G102W BUILDING 1 - SECOND FLOOR PLAN - WEST - PHASING & LIFE SAFETY
1-G105E BUILDING 1 - FIFTH FLOOR PLAN - EAST - PHASING & LIFE SAFETY
1-G105W BUILDING 1 - FIFTH FLOOR PLAN - WEST - PHASING & LIFE SAFETY
11-G101 BUILDING 11 - FIRST FLOOR PLAN - PHASING & LIFE SAFETY
30-G101 BUILDING 30 - FIRST FLOOR PLAN - PHASING & LIFE SAFETY
32-G101 BUILDING 32 - FIRST FLOOR PLAN - PHASING & LIFE SAFETY
40-G101 BUILDING 40 - FIRST FLOOR PLAN - PHASING & LIFE SAFETY
40-G102 BUILDING 40 - SECOND FLOOR PLAN - PHASING & LIFE SAFETY
40-G104 BUILDING 40 - FOURTH FLOOR PLAN - PHASING & LIFE SAFETY
40-G105 BUILDING 40 - FIFTH FLOOR PLAN - PHASING & LIFE SAFETY
40-G106 BUILDING 40 - SIXTH FLOOR PLAN - PHASING & LIFE SAFETY
40-G107 BUILDING 40 - SEVENTH FLOOR PLAN - PHASING & LIFE SAFETY
1-A101E BUILDING 1 - FIRST FLOOR PLAN - EAST
1-A101W BUILDING 1 - FIRST FLOOR PLAN - WEST
1-A102E BUILDING 1 - SECOND FLOOR PLAN - EAST
1-A102W BUILDING 1 - SECOND FLOOR PLAN - WEST
1-A105E BUILDING 1 - FIFTH FLOOR PLAN - EAST
1-A105W BUILDING 1 - FIFTH FLOOR PLAN - WEST
11-A101 BUILDING 11 - FIRST FLOOR PLAN
30-A101 BUILDING 30 - FIRST FLOOR PLAN
32-A101 BUILDING 32 - FIRST FLOOR PLAN
40-A101 BUILDING 40 - FIRST FLOOR PLAN
40-A102 BUILDING 40 - SECOND FLOOR PLAN
40-A104 BUILDING 40 - FOURTH FLOOR PLAN
40-A105 BUILDING 40 - FIFTH FLOOR PLAN
40-A106 BUILDING 40 - SIXTH FLOOR PLAN
40-A107 BUILDING 40 - SEVENTH FLOOR PLAN
COVER SHEET
G001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
ISSUED FOR BIDS AND
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SECURITY CORRECTIONS
JESSE BROWN VAMC CHICAGO, IL
537-19-904
Project Director
08/06/21 J. Hirschhorn D. BrandtRevisions: Date:
MATERIAL LEGEND
ARCHITECTURAL GENERAL NOTESGENERAL PROJECT NOTES ARCHITECTURAL ABBREVIATIONSPROJECT CODE SUMMARY
A. APPLICABLE CODES
B. TYPE OF CONSTRUCTION
C. SPRINKLERED/UNSPRINKLERED
D. OCCUPANCY CLASSIFICATION GROUP
E. OCCUPANCY SEPARATION
F. ALLOWABLE AREA
G. CONSTRUCTION ELEMENTS
ARCHITECTURAL LEGEND
LEGENDS, ABBREVIATIONS AND
NOTES
G002
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
ISSUED FOR BIDS AND
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SECURITY CORRECTIONS
JESSE BROWN VAMC CHICAGO, IL
537-19-904
Project Director
08/06/21 J. Hirschhorn D. BrandtRevisions: Date:
AutoCAD SHX Text EARTH GRAVEL CONCRETE MORTAR, STUCCO, CEMENT PLASTER CONCRETE SECTION SECTION MASONRY UNIT PLAN PLAN STEEL INSULATION, RIGID INSULATION, BATT BRICK WOOD (ROUGH) WOOD (FINISH)
AutoCAD SHX Text A. DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO: DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO: FACE OF EXISTING WALL SURFACE FACE OF NEW MASONRY FACE OF NEW WALL STUDS TOP OF SLAB TOP OF MASONRY ALIGN NEW WALLS WITH EXISTING WHERE NOT OTHERWISE INDICATED. B. COORDINATE WITH ALL DISCIPLINE DRAWINGS FOR COORDINATE WITH ALL DISCIPLINE DRAWINGS FOR ADDITIONAL REQUIREMENTS. COORDINATE OPENINGS IN SLABS, ROOF, AND WALLS. WHERE NEW HOLES IN EXISTING WALLS AND SLABS ARE CREATED FOR CONDUIT, DUCT, OR PIPE PENETRATIONS, COORDINATE SIZE AND LOCATION. PATCH HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT, GRILLES, ETC. WITH MATERIALS MATCHING EXISTING SLAB OR WALL IN STRUCTURE, MATERIAL, THICKNESS, ALIGNMENT, GRADES, AND QUALITY. C. COORDINATE AND PROVIDE SOLID FIRE RETARDANT TREATED COORDINATE AND PROVIDE SOLID FIRE RETARDANT TREATED WOOD BLOCKING FOR WALL-MOUNTED ITEMS BETWEEN STUDS. COORDINATE LOCATIONS WITH COR FOR GOVERNMENT FURNISHED EQUIPMENT. D. `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, STORAGE, HANDLING, INSTALLATION, ADJUSTMENT, AND CLEANING FOR THE ITEM INDICATED. E. SEAL PIPE PENETRATIONS THROUGH SLABS, MASONRY, SEAL PIPE PENETRATIONS THROUGH SLABS, MASONRY, SMOKE RATED PARTITIONS AND FIRE-RATED PARTITIONS WITH THE APPROPRIATE FIRESTOP TO MAINTAIN THE RATING OF THE WALL OR SLAB. SUBMIT CUT SHEETS AND SPECIFICATIONS TO THE COR FOR APPROVAL PRIOR TO INSTALLATION. PROVIDE UL LISTED ASSEMBLIES. F. SKIM COAT ALL DAMAGED EXISTING WALL SURFACES THAT SKIM COAT ALL DAMAGED EXISTING WALL SURFACES THAT REQUIRE PAINTING. G. AT ANY WORK ON SURGICAL FLOORS, SEE SPEC 013526 AT ANY WORK ON SURGICAL FLOORS, SEE SPEC 013526 FOR PERSONAL PROTECTIVE EQUIPMENT (PPE) REQUIREMENTS. H. REMOVED MATERIALS WHICH ARE INDICATED TO BE TURNED REMOVED MATERIALS WHICH ARE INDICATED TO BE TURNED OVER TO THE COR SHALL BE DELIVERED BY THE CONTRACTOR TO A PLACE INDICATED BY THE COR IF APPLICABLE. I. REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE DRAWINGS AND AS REQUIRED FOR NEW CONSTRUCTION. EDGES AND FACES OF DEMOLISHED AREAS SHALL BE REPAIRED TO ACCEPT NEAT INSTALLATION OF NEW CONSTRUCTION OR FINISHES. WHERE EXISTING MATERIALS ARE TO BE REPLACED (WALLS, INSULATION, FLOORING, ETC.) EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND EXPOSED SURFACES SHALL BE PREPARED AS INDICATED OR SPECIFIED PRIOR TO INSTALLATION OF NEW MATERIALS. J. PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN. PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN. REPAIR DAMAGES FROM CONSTRUCTION ACTIVITIES TO EXISTING ITEMS TO REMAIN, AT NO ADDITIONAL COST. WHERE SUCH EXPOSED MATERIALS OR FINISHES TO REMAIN ARE DAMAGED.
AutoCAD SHX Text A. THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY MATERIALS OR EQUIPMENT UNTIL SUBMITTALS FOR SUCH HAVE BEEN APPROVED. B. THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING I.D. THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING I.D. BADGES FOR EACH MEMBER OF HIS WORK FORCE. VALID FORMS OF I.D. ARE REQUIRED TO RECEIVE BADGES. COORDINATE WITH COR. C. ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION SMOKE, DUST, AND DEBRIS SHALL BE SUITABLY PROTECTED TO PREVENT ACCIDENTAL ALARM. ALL SUCH ACTION MUST BE FIRST COORDINATED AND CLEARED WITH COR. ALL FIRE ALARM DEVICES SHALL BE ACTIVE WHENEVER CONTRACTOR'S FORCES ARE NOT PRESENT IN WORK AREA. D. CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTING OFFICER. E. SEE SPECIFICATION SECTIONS 01 00 00 AND 01 35 26 FOR SEE SPECIFICATION SECTIONS 01 00 00 AND 01 35 26 FOR INTERIM LIFE SAFETY MEASURES. F. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS & ALL CONTRACTOR SHALL FIELD VERIFY DIMENSIONS & ALL EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. EXISTING CONDITIONS ARE BASED ON GOVERNMENT FURNISHED EXISTING DRAWINGS AND LIMITED FIELD INVESTIGATION. NOTIFY COR OF ANY DISCREPANCIES PRIOR TO PROCEEDING. G. ALL FINISH COLORS TO MATCH EXISTING ADJACENT FINISHES. ALL FINISH COLORS TO MATCH EXISTING ADJACENT FINISHES. ANY VARIATIONS TO BE SELECTED BY COR WHERE NOT OTHERWISE INDICATED. H. CONTRACTOR TO COORDINATE WITH COR FOR THE EXACT DATE CONTRACTOR TO COORDINATE WITH COR FOR THE EXACT DATE TO REPLACE EACH DOOR (AS NOTED IN DOOR SCHEDULE SHEET A601). FOR EACH DOOR, ALLOW THE VA 1 DAY NOTICE TO SALVAGE ANY HARDWARE AND/OR THE VA POLICE'S MULTIDISCIPLINARY FORCE (FBI, CHICAGO FIRE DEPARTMENT, ETC.) TO EXERCISE USING THEIR LOCKED DOOR DEFEATING TOOLS AND TECHNIQUES. EXISTING LOCKS, DOORS AND FRAMES WILL BE DAMAGED. REPAIRS FOR WALL DAMAGE IS NOT EXPECTED TO OCCUR AND IS NOT IN CONTRACT. I. PROVIDE MINIMUM (1) 16" x 16" ACCESS PANELS IN HARD PROVIDE MINIMUM (1) 16" x 16" ACCESS PANELS IN HARD CEILINGS WHERE DUCTS AND DAMPERS OR OTHER PIPES REQUIRE ACCESS. COORDINATE EXACT LOCATION W/COR. PROVIDE ADDITIONAL ACCESS PANELS IN CHASES AT EACH FLOOR TO ACCESS DUCTS AND DAMPERS. J. OPEN EXISTING DRYWALL AS NECESSARY TO INSTALL NEW OPEN EXISTING DRYWALL AS NECESSARY TO INSTALL NEW DUCTS, PLUMBING AND ELECTRICAL DEVICES. RECONSTRUCT WALL AND FINISH TO MATCH EXISTING.
AutoCAD SHX Text L
AutoCAD SHX Text
BUILDING:
AutoCAD SHX Text
MECHANICAL:
AutoCAD SHX Text
PLUMBING:
AutoCAD SHX Text
FUEL GAS:
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
FIRE:
AutoCAD SHX Text
ENERGY:
AutoCAD SHX Text
LIFE SAFETY:
AutoCAD SHX Text
ACCESSIBILITY:
AutoCAD SHX Text INTERNATIONAL BUILDING CODE (IBC), Latest Edition
AutoCAD SHX Text INTERNATIONAL MECHANICAL CODE (IMC), Latest Edition
AutoCAD SHX Text INTERNATIONAL PLUMBING CODE (IPC), Latest Edition
AutoCAD SHX Text INTERNATIONAL FUEL GAS CODE (IFGC), Latest Edition
AutoCAD SHX Text INTERNATIONAL FIRE CODE (IFC), Latest Edition INTERIOR FINISH PER NFPA 101 Latest Edition CHAPTER 10
AutoCAD SHX Text NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101 LIFE SAFETY CODE (LSC), Latest Edition NFPA 99 HEALTH CARE FACILITIES CODE, Latest Edition NFPA 70 NATIONAL ELECTRIC CODE, Latest Edition NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, Latest Edition NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, Latest Edition
AutoCAD SHX Text VA PG-18-13 BARRIER FREE DESIGN STANDARD, ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS
AutoCAD SHX Text NATIONAL ELECTRIC CODE (NEC), Latest Edition
AutoCAD SHX Text INTERNATIONAL ENERGY CONSERVATION CODE (IECC), Latest Edition
AutoCAD SHX Text
VA MEDICAL CENTER
AutoCAD SHX Text
AUTHORITY HAVING JURISDICTION:
AutoCAD SHX Text
IBC, TABLE 601
AutoCAD SHX Text
SPRINKLERED
AutoCAD SHX Text NFPA 13, Latest Edition
AutoCAD SHX Text
PER NFPA 101, 6.1.5 AND CHAPTER 18
AutoCAD SHX Text
PER IBC, 308.4
AutoCAD SHX Text
TYPE IA
AutoCAD SHX Text
HEALTH CARE
AutoCAD SHX Text
INSTITUTIONAL GROUP, I-2
AutoCAD SHX Text
NFPA 101, TABLE 6.1.14.1
AutoCAD SHX Text
HEALTH CARE
AutoCAD SHX Text
HEALTH CARE
AutoCAD SHX Text
AMBULATORY HEALTH CARE
AutoCAD SHX Text
2 HR
AutoCAD SHX Text
BUSINESS
AutoCAD SHX Text
2 HR
AutoCAD SHX Text
AutoCAD SHX Text
ALLOWABLE AREA WITH MODIFICATIONS
AutoCAD SHX Text
IBC, TABLE 503, SECTION 506
AutoCAD SHX Text
HEALTH CARE
AutoCAD SHX Text
ACTUAL AREA PER FLOOR
AutoCAD SHX Text
ALLOWABLE AREA PER FLOOR
AutoCAD SHX Text
AutoCAD SHX Text
UNLIMITED
AutoCAD SHX Text
UNLIMITED
AutoCAD SHX Text
RATING
AutoCAD SHX Text
STRUCTURAL FRAME
AutoCAD SHX Text
COMMENTS
AutoCAD SHX Text
CODE SECTION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FLOOR CONSTRUCTION
AutoCAD SHX Text
AutoCAD SHX Text
IBC T 601
AutoCAD SHX Text
3 HR
AutoCAD SHX Text
2 HR
AutoCAD SHX Text
IBC T 601
AutoCAD SHX Text
ROOF CONSTRUCTION
AutoCAD SHX Text
1 HR12 HR
AutoCAD SHX Text
AutoCAD SHX Text
BEARING WALLS
AutoCAD SHX Text
3 HR
AutoCAD SHX Text AC ABOVE CEILING ABOVE CEILING ACT ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE AFF ABOVE FINISH FLOOR ABOVE FINISH FLOOR ALUM ALUMINUM ALUMINUM BATT BATT INSULATION BATT INSULATION BD BOARD BOARD BO BOTTOM OF BOTTOM OF CBB CEMENTITIOUS BACKER BOARD CEMENTITIOUS BACKER BOARD CFMF COLD-FORMED METAL FRAMING COLD-FORMED METAL FRAMING CG CORNER GUARD CORNER GUARD CJ CONTROL JOINT CONTROL JOINT C CENTERLINE CENTERLINE CMU CONCRETE MASONRY UNIT CONCRETE MASONRY UNIT CO CASED OPENING CASED OPENING COMM COMMUNICATION COMMUNICATION CONC CONCRETE CONCRETE CONT CONTINUOUS CONTINUOUS COR CONTRACTING OFFICER'S REPRESENTATIVE CONTRACTING OFFICER'S REPRESENTATIVE CT CERAMIC TILE CERAMIC TILE CP CARPET CARPET CPT CARPET TILE CARPET TILE DIA DIAMETER DIAMETER EJ EXPANSION JOINT EXPANSION JOINT ELECT ELECTRICAL ELECTRICAL EQ EQUAL EQUAL ES EXPOSED STRUCTURE EXPOSED STRUCTURE ETC ET CETERA ET CETERA EWC ELECTRIC WATER COOLER ELECTRIC WATER COOLER EXIST EXISTING EXISTING EXP EXPOSED EXPOSED FAC FIN FACTORY FINISH FACTORY FINISH FD FLOOR DRAIN FLOOR DRAIN FE FIRE EXTINGUISHER FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FIRE EXTINGUISHER CABINET FF FINISH FLOOR FINISH FLOOR FHC FIRE HOSE CABINET FIRE HOSE CABINET FIN FINISH FINISH FLR FLOOR FLOOR FO FACE OF FACE OF FV FIELD VERIFY (PRIOR TO ORDERING OR CUTTING) FIELD VERIFY (PRIOR TO ORDERING OR CUTTING) GA GAGE GAGE GWB GYPSUM WALL BOARD GYPSUM WALL BOARD GYP GYPSUM GYPSUM INSUL INSULATION INSULATION HC HANDICAPPED HANDICAPPED HM HOLLOW METAL HOLLOW METAL HPDL HIGH-PRESSURE DECORATIVE LAMINATE HIGH-PRESSURE DECORATIVE LAMINATE HVAC HEATING, VENTILATION AND AIR-CONDITIONING HEATING, VENTILATION AND AIR-CONDITIONING JT JOINT JOINT LVT LUXURY VINYL TILE LUXURY VINYL TILE MATL MATERIAL MATERIAL MAX MAXIMUM MAXIMUM MECH MECHANICAL MECHANICAL MFR MANUFACTURER MANUFACTURER MIN MINIMUM MINIMUM MO MASONRY OPENING MASONRY OPENING MTL METAL METAL NIC NOT IN CONTRACT NOT IN CONTRACT NTS NOT TO SCALE NOT TO SCALE OC ON CENTER ON CENTER OH OPPOSITE HAND OPPOSITE HAND P PAINT PAINT PLAM PLASTIC LAMINATE PLASTIC LAMINATE PLS PLASTER PLASTER POR PORCELAIN TILE PORCELAIN TILE PR PAIR PAIR PT PRESSURE TREATED PRESSURE TREATED QT QUARRY TILE QUARRY TILE RB RUBBER BASE RUBBER BASE REF REFRIGERATOR REFRIGERATOR REQ'D REQUIRED REQUIRED RES RESINOUS FLOORING RESINOUS FLOORING RES-C RESINOUS EPOXY CEILING COATING RESINOUS EPOXY CEILING COATING RES-W RESINOUS EPOXY WALL COATING RESINOUS EPOXY WALL COATING RF RUBBER FLOORING RUBBER FLOORING RO ROUGH OPENING ROUGH OPENING SC SPECIALTY HIGH BUILD GLAZED COATING SPECIALTY HIGH BUILD GLAZED COATING SCW SOLID CORE WOOD SOLID CORE WOOD SD SOAP DISPENSER SOAP DISPENSER SIM SIMILAR SIMILAR SND SANITARY NAPKIN DISPENSER SANITARY NAPKIN DISPENSER SP SPECIAL FACED SPECIAL FACED SS STAINLESS STEEL STAINLESS STEEL SSM SOLID SURFACE MATERIAL SOLID SURFACE MATERIAL ST STEEL STEEL SUBS SUBSTRATE SUBSTRATE TB TACK BOARD TACK BOARD TELE TELEPHONE TELEPHONE TO TOP OF TOP OF TP TOILET PAPER TOILET PAPER TYP TYPICAL TYPICAL UNO UNLESS NOTED OTHERWISE UNLESS NOTED OTHERWISE VCT VINYL COMPOSITION TILE VINYL COMPOSITION TILE VWC VINYL WALL COVERING VINYL WALL COVERING WD WOOD WOOD WR WATER RESISTANT WATER RESISTANT WSF WELDED SHEET FLOORINGWELDED SHEET FLOORING
AutoCAD SHX Text A
AutoCAD SHX Text + 0'-6"
AutoCAD SHX Text F.E.C.
AutoCAD SHX Text FIRE EXTINGUISHER CABINET ROOM NAME AND NUMBER DOOR NUMBER DEMOLITION NOTE KEY NOTE WINDOW TYPE PARTITION TYPE DETAIL CALLOUT DETAIL NUMBER SHEET WHERE DETAIL IS DRAWN SECTION CALLOUT SECTION NUMBER SHEET WHERE SECTION IS DRAWN VERTICAL ELEVATION COLUMN CENTERLINE DESIGNATION EXTERIOR ELEVATION CALLOUT ELEVATION NUMBER SHEET WHERE ELEVATION IS DRAWN INTERIOR ELEVATION CALLOUT ELEVATION NUMBER SHEET WHERE ELEVATION IS DRAWN
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
NAME
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text A301
AutoCAD SHX Text
AutoCAD SHX Text A201
AutoCAD SHX Text
AutoCAD SHX Text
GA4
AutoCAD SHX Text A401
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INFECTION CONTROL PROJECT INFORMATION
INFECTION CONTROL PROJECT INFORMATION
INFECTION CONTROL PLAN NOTES
PHASING GENERAL NOTES
PHASING NOTES LEGEND AND
DETAILS
G003
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
ISSUED FOR BIDS AND
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SECURITY CORRECTIONS
JESSE BROWN VAMC CHICAGO, IL
537-19-904
Project Director
08/06/21 J. Hirschhorn D. BrandtRevisions: Date:
AutoCAD SHX Text CONSTRUCTION ACTIVITY-FIRE RISK: TYPE C+D PATIENT RISK GROUP: HIGH OR HIGHEST, PER SPEC. CLASS OF PRECAUTION MATRIX: III & IV
AutoCAD SHX Text A. REFER TO LIST OF REQUIRED INFECTION CONTROL PRECAUTIONS OUTLINED BY CLASS IN REFER TO LIST OF REQUIRED INFECTION CONTROL PRECAUTIONS OUTLINED BY CLASS IN SPECIFICATION 013526 FOR ADDITIONAL INFORMATION. B. REFER TO DRAWINGS, SECURITY (SC) DOCUMENTS, SPECIFICATIONS AND DOOR HARDWARE REFER TO DRAWINGS, SECURITY (SC) DOCUMENTS, SPECIFICATIONS AND DOOR HARDWARE SCHEDULE FOR ADDITIONAL INFORMATION. C. COORDINATE FULL SCOPE OF WORK WITH ENGINEERING DRAWINGS (E & SC) AND FIELD COORDINATE FULL SCOPE OF WORK WITH ENGINEERING DRAWINGS (E & SC) AND FIELD VERIFICATION. CONTRACTOR IS RESPONSIBLE FOR SCOPE OF ABOVE CEILING WORK REQUIRED. D. COORDINATE LOCATION OF TEMPORARY INFECTION CONTROL (IC) BARRIER WALL CONSTRUCTION COORDINATE LOCATION OF TEMPORARY INFECTION CONTROL (IC) BARRIER WALL CONSTRUCTION AND INFECTION CONTROL(IC) MEASURES WITH COR AND PATIENT SAFETY/INFECTION CONTROL REPRESENTATIVE. TEMPORARY IC BARRIER WALL CONSTRUCTION LOCATIONS IN DRAWINGS ARE APPROXIMATE. CONTRACTOR SHALL PROVIDE MEASURED DRAWINGS TO COR AND PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE ONCE ICRA PROTOCOLS AND SCHEDULE IS APPROVED. E. SCHEDULE AND TIME OF CONSTRUCTION WORK TO BE APPROVED BY COR, HOSPITAL SCHEDULE AND TIME OF CONSTRUCTION WORK TO BE APPROVED BY COR, HOSPITAL ADMINISTRATION AND NURSING STAFF BEFORE CONSTRUCTION MAY BEGIN. PROVIDE PHASING INFORMATION INCLUDING ABOVE CEILING WORK IN THE CONTRACTOR PROVIDED CONSTRUCTION SCHEDULE (PER SPECIFICATIONS) FOR WORK ALSO REQUIRED ABOVE THE FLOOR PLATE OF THE PROJECT BOUNDARY. F. ALL WORK SHALL TAKE PLACE BETWEEN THE HOURS OF 5:00PM AND 5:00 AM THE NEXT DAY ALL WORK SHALL TAKE PLACE BETWEEN THE HOURS OF 5:00PM AND 5:00 AM THE NEXT DAY DURING WORK WEEK AND ON WEEKE3NDS BASED ON SUBMITTED AND APPROVED SCHEDULE. IN AREAS THAT REQUIRE ABOVE CEILING WORK WHERE CEILINGS ARE TO REMAIN, CEILING TILES SHALL BE REMOVED AND STORED IN A SAFE MANOR UNTIL CEILING TILES CAN BE REINSTALLED. DAMAGES AND BROKEN CEILING TILES SHALL BE REPLACED BY CONTRACTOR. G. EXIT/ACCESS FOR ADJACENT OPERATIONAL AREAS SHALL BE MAINTAINED DURING NORMAL EXIT/ACCESS FOR ADJACENT OPERATIONAL AREAS SHALL BE MAINTAINED DURING NORMAL BUSINESS HOURS. ANY INTERRUPTIONS MUST BE REQUESTED AHEAD OF TIME AND APPROVED. SEE SPECIFICATION 013526 AND MEMO 001S-08-18 FOR PROCEDURES AND HOURS OF OPERATION. H. WORK REQUIRING VIBRATION OR LOUD NOISE SHALL TAKE PLACE BETWEEN THE HOURS OF WORK REQUIRING VIBRATION OR LOUD NOISE SHALL TAKE PLACE BETWEEN THE HOURS OF 5:00 PM AND 5:00 AM DURING WORK WEEK AND ON WEEKE3NDS BASED ON SUBMITTED AND APPROVED SCHEDULE. EVERY EFFORT SHALL BE MADE TO KEEP NOISE AND VIBRATION TO A MINIMUM. I. PROVIDE THE FOLLOWING INFECTION CONTROL MEASURES: A 24"X36" STICKY WALK OFF MAT PROVIDE THE FOLLOWING INFECTION CONTROL MEASURES: A 24"X36" STICKY WALK OFF MAT AND HAND SANITIZER AT EACH TEMPORARY DOOR LOCATION. MAT SHALL BE REPLACED OR CLEANED AS NECESSARY. J. PROVIDE THE VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH TEMPORARY DOOR PROVIDE THE VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH TEMPORARY DOOR LOCATION. K. CONTRACTOR SHALL SUPPLY SPILL KIT. SPILL KIT TO INCLUDE SHOP VAC, MULTI-PURPOSE CONTRACTOR SHALL SUPPLY SPILL KIT. SPILL KIT TO INCLUDE SHOP VAC, MULTI-PURPOSE SPILL CONTROL SORBETS TO ABSORB NON AGGRESSIVE LIQUIDS UP TO 30 GALLONS. L. ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED WITH 4 MIL. POLY ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED WITH 4 MIL. POLY SHEET. M. ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT BOUNDARY THROUGH THE ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG VA APPROVED ROUTE IN ENCLOSED DUMPSTER CART DESIGNED FOR SUCH PURPOSED WITH A LID. N. ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY STORED IN ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY STORED IN DESIGNATED AREAS AND APPROVED CONTAINERS. FLAMMABLE MATERIALS SHALL NOT BE STORED IN THE FACILITY. O. PROVIDE CONTAINMENT CART FOR ABOVE CEILING ACCESS OUTSIDE PROJECT BOUNDARY.PROVIDE CONTAINMENT CART FOR ABOVE CEILING ACCESS OUTSIDE PROJECT BOUNDARY.
AutoCAD SHX Text
1. PROVIDE TEMPORARY 1 HR FIRE RATED SMOKE BARRIER WALL CONSTRUCTION PER NFP1 PROVIDE TEMPORARY 1 HR FIRE RATED SMOKE BARRIER WALL CONSTRUCTION PER NFP1 241. REFER TO DETAIL 1/G003. 2. PROVIDE TEMPORARY INFECTION CONTROL CONSTRUCTION DOOR WITH CARD READER PROVIDE TEMPORARY INFECTION CONTROL CONSTRUCTION DOOR WITH CARD READER ACCESS. REFER TO ELEVATION 2/G003. 3. PROVIDE TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION. REFER TO DETAIL PROVIDE TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION. REFER TO DETAIL 3/G003. SYSTEM SHALL BE 1 HR RATED.
AutoCAD SHX Text
AutoCAD SHX Text A. PROJECT AREAS TO BE OCCUPIED BY STAFF AND VETERANS THROUGHOUT CONSTRUCTION. PROJECT AREAS TO BE OCCUPIED BY STAFF AND VETERANS THROUGHOUT CONSTRUCTION. B. REFER TO SPECIFICATION 01 00 00 FOR INFORMATION ON WORK DURING FOR EACH REFER TO SPECIFICATION 01 00 00 FOR INFORMATION ON WORK DURING FOR EACH PHASE AND AREA OF WORK.
AutoCAD SHX Text
ADJUSTABLE UPPER PANEL(S). SLIDES TO CEILING HEIGHT UP TO 10'-0".
AutoCAD SHX Text
ADJUSTABLE HYDRAULIC CLOSER AVAILABLE
AutoCAD SHX Text
1" X 1" ANGLE MOUNTED TO GASKET AND ADHERED TO FORM SEAL WITH FRAME
AutoCAD SHX Text
1" X 1" ANGLE MOUNTED TO GASKET AND ADHERED TO FORM SEAL WITH FRAME
AutoCAD SHX Text 1/4" X 2" SOLID ALUMINUM THRESHOLD STRIP WITH NEOPRENE GASKET MATERIAL SEAL TO THE FLOOR.
AutoCAD SHX Text TEMPORARY IC BARRIER WALL CONSTRUCTION SYSTEM MUST BE 1HR RATED, PER NFPA 241. (ALTERNATIVELY PROVIDE FULL FIRE-WATCH)
AutoCAD SHX Text G003
AutoCAD SHX Text
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text
TEMPORATY INFECTION CONTROL BARRIER
AutoCAD SHX Text
ADJUSTABLE UPPER PANEL(S). SLIDES TO CEILING HEIGHT UP TO 10'-0".
AutoCAD SHX Text
ADJUSTABLE HYDRAULIC CLOSER AVAILABLE
AutoCAD SHX Text
1" X 1" ANGLE MOUNTED TO GASKET AND ADHERED TO FORM SEAL WITH FRAME
AutoCAD SHX Text
CONTINUOUS POLYETHYLENE HINGE
AutoCAD SHX Text SELF LATCHING, LOCKING HANDLE WITH KEYED OUTSIDE AND THUMBTURN INSIDE. 4 DIGIT COMBINATION PUSHBUTTON LOCKED AVAILABLE
AutoCAD SHX Text
GASKETED SWEEP TO PREVENT DUST AND DEBRIS ESCAPE
AutoCAD SHX Text 1/4" X 2" SOLID ALUMINUM THRESHOLD STRIP WITH NEOPRENE GASKET MATERIAL SEAL TO THE FLOOR.
AutoCAD SHX Text
SYSTEM MUST BE 1HR RATED, PER NFPA 241. (ALTERNATIVELY PROVIDE FULL FIRE-WATCH)
AutoCAD SHX Text
PUBLIC SIDE
AutoCAD SHX Text G003
AutoCAD SHX Text
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text
TEMPORARY INFECTION CONTROL BARRIER DOOR
AutoCAD SHX Text
CONSTRUCTION SIDE
AutoCAD SHX Text
EXISTING DECK
AutoCAD SHX Text
CONTINUOUSLY ADHERE 6-MIL. FIRE RETARDANT POLY TO DECK WITH TAPE
AutoCAD SHX Text
2" DEEP LEF 3 " STEEL SLIP TRACK58" STEEL SLIP TRACK
AutoCAD SHX Text
12" VINYL FACED BATT INSULATION
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
6-MIL FIRE RETARDANT POLY INTERIOR SIDE
AutoCAD SHX Text
3 " STEEL STUD TRACK @ 16" O.C.58" STEEL STUD TRACK @ 16" O.C.
AutoCAD SHX Text
3 " STEEL STUD TRACK58" STEEL STUD TRACK
AutoCAD SHX Text
COMPRESSIBLE FOAM OR RUBBER SILL
AutoCAD SHX Text
CONTINUOUSLY ADHERE FIRE RETARDANT POLY TO FLOOR WITH TAPE
AutoCAD SHX Text
TEMPORARY IC BARRIER WALL CONSTRUCTION( DUST WALL)
AutoCAD SHX Text G003
AutoCAD SHX Text
AutoCAD SHX Text 1/2" = 1'-0"
TEMPORARY DUST CONTROL BARRIER
ROLLING SHUTTER ROLLING SHUTTER
OVER HEAD DOOR
HAC
STORAGE
FIRE
CLOSET
PNEUMATIC
TUBE
FAC
FAC
TEL
FIRE
HOSE
11E1
CLOSET
1541A
CLOSET
1545B
TELECOMMUNICATION
STAFF OFFICE
ELEVATOR
NO S5
ELEVATOR
NO S6
ELEVATOR
NO P1
ELEVATOR
NO P2
CORRIDOR
C1511
CORRIDOR
C1404
TOILET
1491A
ELECTRICAL
CLEAN SUPPLY
CORRIDOR
C1102
ENTRANCE
CORRIDOR
C1401
CORRIDOR
C1403
CORRIDOR
C1402
CORRIDOR
C1405
CORRIDOR
C1407
CORRIDOR
C1406
CORRIDOR
C1409
CORRIDOR
C1445
WAITING RM
WOMENS
TOILET
MENS TOILET
HEALTH VET
CO-ORDR
CREDIT
UNION
FIRE
CONTROL
PATIENT
ADVOCATE
OFFICE
OPTICAL
DISPENSARY
1410A
TRIAGE
TRIAGE
ELECTRICAL
SWITCH RM
14E2
TRIAGE
PHYSICIAN
ASSIST
ELECTRICAL
14E1
ADDICTION
CONSULT
RM
RECEPTION
CONSULT
RM
PROGRAM
SUPPORT
1459A
E D OFFICE
ELECTRICAL
14E3
FLU
CLINIC
CONSULT
RM
HAC
TOILET
TEL
14T1
VESTIBULE/STAIR
STAIR
NO 2
PAC
CO-ORDR
OFFICE
CHIEF
CONSULT
RM
CONSULT
RM
CONSULT
RM
EMS
HOUSE
KEEPING
ELEVATOR
NO P7
ELEVATOR
NO P8
TEL
CLOSET
14T2
14E4
STAIR
NO 1
ELEVATOR
NO P3
ELEVATOR
NO P4
NURSE STATION EMERGENCY RM
EQUIP STORAGE
LOUNGE
ELECTRICAL
14E6
COMM
14T3
BEREAVEMENT
RM
1475A
SOILED
UTILITY
EXAM RM-7
1470G
EXAM RM-6
1470F
EXAM RM-5
1470E
EXAM RM-4
1470D
EXAM RM-3
1470C
EXAM RM-2
1470B
E D MGR
ICE MACH
EXAM RM-1
1470AER HALLWAY
TRAVEL PAY
STORAGE
RECEPTION AND
ADMISSION
AMBULATORY
CARE SUPV
OFFICE
CHIEF
AMBULATORY
CORRIDOR
C1411
VTS MANAGER
EMS STORAGE
1431A
ER STORAGE
1431B
TRIAGE
E D ATTENDING
TRIAGE
MEDICAL
SUPPORT
SUPERV
1431C
TELEPHONE
TRIAGE
TOILET
VESTIBULE
C1408
GARAGE
EMS
CLEAN
SUPPLY
CLEAN
LINEN
TOILET
EXAM RM-15
1470R
EXAM RM-14
1470Q
EXAM RM-13
1470P
EXAM RM-12
1470N
EXAM RM-11
1470M
EXAM RM-10
1470L
MEDS
1470H
EXAM RM-8
1470J
EXAM RM-9
1470K
MENS
TOILET
CONFERENCE RM
WOMENS
TOILET
TOILET
1497 ON CALL
ADMIN OFFICE
EXAM RM
ON CALL
1491B
STAIR
EXAM
RM
EXAM RM
EXAM RM
DONATED
CLOTHING
STORAGE
EMS LINEN RM
CORRIDOR
C1501
PHARMACY IV
STORAGE
BIOHAZARD
CONTAINER
GAS STORAGE
ELEVATOR MECH
ELEVATOR
FOYER
MORGUE
ELEVATOR
STAIR
NO 5
TELECOMMUNICATION RM
14T4
ELECTRICAL
14E7
TOILET
1499A
DOCTOR
OFFICE
DOCTOR
OFFICE
DOCTOR
OFFICE
SECRET
OFFICE
STORAGE
COMP AND
PENS STAFF
WAITING RM
SUPV OFFICE
EXAM RM
EXAM RM
FORENSIC
PSY
FELLOW
MECH RM
POLICE
OPERATION
ARMORY RM
TOILET
STORAGE
1554B
SQUAD RM OFFICE
PHYSICAL
SECURITY
1540B
PHYSICAL
SECURITY
1540A
EVIDENCE
STORAGE
1542A
EVIDENCE
OFFICE VIEW
1544A
OPERATION
CAPTAIN
DEPUTY CHIEF
VESTIBULE
CORRIDOR
C1505
CORRIDOR
C1504
ENTRANCE/LOBBY
C1103
ELECTRICAL
1541B
VESTIBULE
C1116
SECY OFFICE
OFFICE/
COPIER
1545A
HOLD
CELL
1556 HOLD
CELL
WAITING RM
CONSULT
RM - 1
CONSULT
RM - 2
WAITING
RECEPTION
TECH WORK
TOILET
HOLDING
CORRIDOR
C1508
CLEAN
CLEAN
SUPPLY
CORRIDOR
C1502
HAC
FIRE ALARM
CORRIDOR
C1503
GAS CYLINDER
STORAGE
EMS STORAGE
CT IMAGING RM - 2
CONTROL RM - 2
1528B TOILET
1528A
CONTROL RM - 1
1530A
TOILET
1530B
SWITCHGEAR RM15E5
CORRIDOR
STAIRWELL
VESTIBULE
VESTIBULE
CORRIDOR
CLOSET
VESTIBULE
ELECTRICAL
CLOSET
OPTICAL
WAITING RM
CORRIDOR
C1506B
1570A
1521A
C1505
1555B
1499B
1490AM1
NO 5A
1436A
1467NO 2
1410B
C1404
C1404
ATS RM
1570C
ELECTRIC
CLOSET
14E5
POLICE
OFFICE
DAYLIGHT
WELL
MATCH LINE MATCH LINE
BLDG 1 EAST
BLDG 1 WEST
PHASING
GENERAL NOTES
BUILDING 1 PHASED CONSTRUCTION KEY
NOTES - FIRST FLOOR - EAST
DOOR AND FRAME DELIVERY NOTES
BLDG 1 - 1ST FLR PLAN - EAST -
PHASING & LIFE SAFETY
1-G101E
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
ISSUED FOR BIDS AND
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SECURITY CORRECTIONS
JESSE BROWN VAMC CHICAGO, IL
537-19-904
Project Director
08/06/21 J. Hirschhorn D. BrandtRevisions: Date:
AutoCAD SHX Text 0'
AutoCAD SHX Text
SCALE: 3/32"=1'-0"
AutoCAD SHX Text 32'
AutoCAD SHX Text 24'
AutoCAD SHX Text 16'
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text 1-G101E
AutoCAD SHX Text
AutoCAD SHX Text 3/32" = 1'-0"
AutoCAD SHX Text
BUILDING 1 - FIRST FLOOR PLAN - EAST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 11A
AutoCAD SHX Text 11B
AutoCAD SHX Text
AutoCAD SHX Text A401
AutoCAD SHX Text 1-4
AutoCAD SHX Text A. THIS IS A CONCEPTUAL PHASING PLAN. CONTRACTOR SHALL REVIEW THE THIS IS A CONCEPTUAL PHASING PLAN. CONTRACTOR SHALL REVIEW THE DRAWINGS AND SPECIFICATIONS AND INCLUDE PHASING IN HIS/HER BID IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. B. THE PRIMARY GOAL OF THIS PHASING DOCUMENT IS TO IDENTIFY THE THE PRIMARY GOAL OF THIS PHASING DOCUMENT IS TO IDENTIFY THE ADJACENCIES THAT WILL REQUIRE THE SEPARATE TIMING OF THE WORK ON PARTICULAR DOORS AGAINST NEARBY DOORS TO BE WORKED ON. WORK IN ALL PHASES WILL REQUIRE COORDINATION WITH HOSPITAL DEPARTMENTS (THROUGH THE COR) AS DOORS WITHIN THE PROJECT SCOPE IN CLOSE PROXIMITY CAN NOT BE WORKED ON SIMULTANEOUSLY. C. THE EXACT SEQUENCE OF WORK IS TO BE WORKED OUT THROUGH THE EXACT SEQUENCE OF WORK IS TO BE WORKED OUT THROUGH MEETINGS WITH COR AND AFFECTED HOSPITAL DEPARTMENTS. D. ANTICIPATED WORK AREAS ARE INDICATED TO PROVIDE FOR ON-GOING ANTICIPATED WORK AREAS ARE INDICATED TO PROVIDE FOR ON-GOING VAMC HEALTHCARE FUNCTIONS DURING CONSTRUCTION. THE CONSTRUCTION BARRIERS ARE IDENTIFIED AND LOCATED ON THE ARCHITECTURAL DRAWINGS. E. CONSTRUCTION WORK WILL BE RESTRICTED TO OVERNIGHT AND WEEKEND CONSTRUCTION WORK WILL BE RESTRICTED TO OVERNIGHT AND WEEKEND HOURS (U.N.O.) AS STATED IN THE SPECIFICATIONS. F. COORDINATE AND SCHEDULE ALL WORK WITH THE COR. COORDINATE AND SCHEDULE ALL WORK WITH THE COR. G. PHASING WILL ALSO REQUIRE TEMPORARY ALTERNATE EMERGENCY EGRESS PHASING WILL ALSO REQUIRE TEMPORARY ALTERNATE EMERGENCY EGRESS ROUTES WHICH WILL BE INCLUDED IN PHASING KEY NOTES BELOW.
AutoCAD SHX Text (KEY NOTES APPLY TO THIS SHEET ONLY) 1. WORK ON EXTERIOR DOOR 04 AT MORGUE ELEVATOR FOYER HAS NO WORK ON EXTERIOR DOOR 04 AT MORGUE ELEVATOR FOYER HAS NO NEARBY DOOR CONFLICTS. GC TO COORDINATE WITH COR (FOR MORGUE CONTACT) FOR TIMING OF CONSTRUCTION. 2. WORK ON EXTERIOR DOOR 06 AT VESTIBULE 1499B WILL CONFLICT WITH WORK ON EXTERIOR DOOR 06 AT VESTIBULE 1499B WILL CONFLICT WITH DOOR 07 AT STAIR 5. TELECOM DEPT MUST EXIT THROUGH STAIR 5 WHILE DOOR 06 IS WORKED ON. GC TO COORDINATE WITH COR (FOR TELECOMMUNICATIONS DEPT. CONTACT) FOR TIMING OF CONSTRUCTION. 3. WORK ON EXTERIOR DOOR 07 AT STAIR NO.5 WILL CONFLICT WITH DOOR WORK ON EXTERIOR DOOR 07 AT STAIR NO.5 WILL CONFLICT WITH DOOR 06 AT TELECOM. DEPT. STAIR NO.5 PROVIDES EMERGENCY EGRESS FOR BASEMENT THROUGH 10TH FLOOR OF BLDG 1 EAST. ANY DEPT'S IN THESE AREAS OPEN DURING WORK ON THIS DOOR WILL BE ROUTED THROUGH STAIR NO.1 ADJACENT TO ELEVATOR P4. GC TO COORDINATE WITH COR (FOR ALL AFFECTED DEPT.) FOR TIMING OF CONSTRUCTION. 4. WORK ON INTERIOR DOOR 09 BETWEEN CORRIDOR C1404 AND SERVICE WORK ON INTERIOR DOOR 09 BETWEEN CORRIDOR C1404 AND SERVICE ELEVATOR FOYER HAS NO NEARBY DOOR CONFLICTS. SERVICE ELEVATOR S6 WILL BE OUT OF SERVICE WHILE WORK ON THIS DOOR IS PERFORMED. GC TO COORDINATE WITH COR (FOR ALL AFFECTED DEPT.) FOR TIMING OF CONSTRUCTION. 5. WORK ON EXTERIOR DOOR 10 AT STAIR NO.5A WILL CONFLICT WITH DOOR WORK ON EXTERIOR DOOR 10 AT STAIR NO.5A WILL CONFLICT WITH DOOR 07 AT STAIR 5A AND DOOR 18 AT NEW POLICE OBSERVATION ROOM 1438. STAIR NO.5A PROVIDES EMERGENCY EGRESS FOR THE EMERGENCY SUITE AND THE AUDITORIUM ON 2ND FLOOR OF BLDG 1 EAST. THE AUDITORIUM WILL NOT BE USABLE WHILE DOOR 10 IS WORKED ON. THE EMERGENCY SUITE EGRESS ROUTE THROUGH CORRIDOR C1404 BACK TO STAIR NO.5 AND DOOR 07. GC TO COORDINATE WITH COR (FOR ALL AFFECTED DEPT.) FOR TIMING OF CONSTRUCTION. 6. WORK ON EXTERIOR OVERHEAD DOORS 11A AND 11B AT GARAGE 1430 WORK ON EXTERIOR OVERHEAD DOORS 11A AND 11B AT GARAGE 1430 WILL ONLY CONFLICT WITH EACH OTHER. WHILE WORK ON DOOR 11A IS BEING PERFORMED, DOOR 11B WILL BE LEFT OPEN TO PERMIT AMBULANCE ACCESS TO THE EMERGENCY SUITE. THIS IS SWAPPED WHEN WORK ON DOOR 11B IS DONE. 7. WORK ON INTERIOR DOOR 18 AT NEW POLICE OBSERVATION ROOM 1438 WORK ON INTERIOR DOOR 18 AT NEW POLICE OBSERVATION ROOM 1438 WILL CONFLICT WITH DOOR 07 AT STAIR 5A AND DOOR 10 AT STAIR NO.5A. ADDITIONALLY, WORK ON ROOM 1438 WILL RESULT IN A SINGLE MEANS OF EGRESS FOR THE EMERGENCY SUITE THROUGH A SINGLE 3'-0" WIDE DOOR. THE SINGLE EMERGENCY SUITE EGRESS ROUTE IS THROUGH CORRIDOR C1404 TO STAIR NO.5A AND DOOR 10. GC TO COORDINATE WITH COR (FOR EMERGENCY DEPT.) FOR TIMING OF CONSTRUCTION. 8. WORK ON INTERIOR DOOR 28 BETWEEN CORRIDORS C1406 AND C1404 WORK ON INTERIOR DOOR 28 BETWEEN CORRIDORS C1406 AND C1404 HAS NO NEARBY DOOR CONFLICTS. GC TO COORDINATE WITH COR (FOR HOSPITAL ADMIN.) FOR TIMING OF CONSTRUCTION.
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY AND INSTALLATION THE CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY AND INSTALLATION MEANS AND METHODS FOR ALL NEW DOORS AND FRAMES TO THE WORK SITES THROUGHOUT THE BUILDING. 2. THE CONTRACTOR SHALL REVIEW THE DRAWINGS, SPECIFICATIONS AND THE CONTRACTOR SHALL REVIEW THE DRAWINGS, SPECIFICATIONS AND EXISTING BUILDING DRAWINGS TO DETERMINE DELIVERY ROUTES FOR THE DOORS AND FRAMES TO THE PROJECT WORK SITES THROUGHOUT THE BUILDING. THE CONTRACTOR SHALL PROVIDE DRAWINGS DEMONSTRATING THAT THE DELIVERY PATH IS ACCEPTABLE FOR REVIEW AND APPROVAL BY THE VA (COR) PRIOR TO PROCEEDING WITH DOOR AND FRAME DELIVERY INTO THE FACILITY. 3. THE DOOR AND FRAME DELIVERY TO THE PROJECT WORK SITE SHALL BE THE DOOR AND FRAME DELIVERY TO THE PROJECT WORK SITE SHALL BE SCHEDULED FOR SAME DAY INSTALLATION. STOCK PILING DOORS AND FRAMES WITHIN THE BUILDING WILL NOT BE PERMITTED UNLESS IT IS DEMONSTRATED TO BE ACCEPTABLE THROUGH THE REVIEW PROCEDURE NOTED ABOVE. 4. ALL EXISTING EXTERIOR AND INTERIOR FINISHES OR CONDITIONS DAMAGED ALL EXISTING EXTERIOR AND INTERIOR FINISHES OR CONDITIONS DAMAGED AS A RESULT OF THE DOOR AND FRAME DELIVERY SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING AT NO COST TO THE OWNER.
FIRE
HOSE
11E1
CLOSET
CLOSET
1541A
FAC
1575B
CLOSET
1545B
DIGITAL RADIOLOGY
ELEVATOR
NO P1
ELEVATOR
NO P2
CORRIDOR
C1511
PREP/
RECOVERY
CORRIDOR
C1405
CORRIDOR
C1409
HEALTH VET
CO-ORDR
CREDIT
UNION
FIRE
CONTROL
PATIENT
ADVOCATE
OFFICE
OPTICAL
DISPENSARY
1410A
TRIAGE
ADDICTION CONSULT CONSULT
PAC
CO-ORDR
OFFICE
CHIEF
CONSULT
RM
CONSULT
RM
CONSULT
RM
EMS
ELEVATOR
NO P7
ELEVATOR
NO P8
ELEVATOR
NO P3
DONATED
CLOTHING
STORAGE
EMS LINEN RM
VESTIBULE
C1507
CORRIDOR
C1606
POLICE
OPERATION
CORRIDOR
C1510
CORRIDOR
C1505
PREPARATION
SOILED RECEIVING /
DECONTAM
SPD CHIEF
SPD
STAFF
OFFICE
1646TOILET
1646A
STAFF
LOCKER
TOILET
1643A
STAFF
LOUNGE
ETO
SVC
ETO
RM
1639A
HAC
16H6
CART STAGING
AREA
CART
WASH
VENDING MACHS
CHAPLAIN
OFFICE
CHIEF CHAPLAIN
ELEVATOR
PIT
P-27
ELECTRICAL RM
16E1
ELEVATOR
MACH RM
SECURED
ITEMS
WHEELCHAIR
WASH
ESCORT
WAITING RM
FIRE COMMAND
CENTER
STAIR
NO 13
SECY
VESTIBULE
BLESSED
SACRAMENT
CHAPEL
SACRISTY
CORRIDOR
C1607
ELEVATOR
P-26
HAC
16H5
TOILET
STAFF LOCKER
STAFF
LOUNGE
STAFF LOCKER
TOILET
MANUAL
EQUIP WASH
ARMORY RM
TOILET
STORAGE
1554B
SQUAD RM OFFICE
PHYSICAL
SECURITY
1540B
PHYSICAL
SECURITY
1540A
EVIDENCE
STORAGE
1542A
EVIDENCE
OFFICE VIEW
1544A
OPERATION
CAPTAIN
DEPUTY CHIEF
VESTIBULE
CORRIDOR
C1505
CORRIDOR
C1504
ENTRANCE/LOBBY
C1103
ELECTRICAL
1541B
VESTIBULE
C1116
SECY OFFICE
OFFICE/
COPIER
1545A
CORRIDOR
C1509
POLICE CHIEF
RAD EXAM
DOCTOR
OFFICE
RAD
OFFICE
ULTRASOUND
HOLD
CELL
1556 HOLD
CELL
RADIOLOGY
OFFICE
RADIOLOGY
READING RM
RADIOLOGY
OFFICE
RAD
OFFICE
READING RM
TOILET
SPD SUPV
OFFICE
SPD RECEIVING
STORAGE
SECY OFFICE
RADIOLOGY SVC
CONFERENCE RM
FAN RM
CHIEF OF
SPS
COMPUTER
CABINET
1581A
OPERATION MGR
RADIOLOGY SVC
CHIEF RADIOLOGY
ELECTRICAL
CLOSET
15E2
TELEPHONE
CLOSET
15T1
HAC
STAIR
NO 3
WAITING RM
CONSULT
RM - 1
CONSULT
RM - 2
GOWNED
WAITING
COPY
RECEPTION
TECH WORK
TOILET
MENS
CHANGING
WOMENS
CHANGING
INPT
HOLDING
CORRIDOR
C1506
CORRIDOR
CORRIDOR
C1508
CLEAN
CLEAN
SUPPLY
HAC
FIRE ALARM
CORRIDOR
C1503
GAS CYLINDER
STORAGE
EMS STORAGE
CT IMAGING RM - 2
CONTROL RM - 2
1528B TOILET
1528A
CONTROL RM - 1
1530A
TOILET
1530B
CT IMAGING RM - 1
ELECTRICAL RM
15E3
RADIOLOGY /
FLUOROSCOPIC RM
TOILET
1533A
MECH
ULTRASOUND
RADIOLOGY
SUPPLY
DIGITAL RADIOLOGY
ELECTRICAL
15E4
SWITCHGEAR RM15E5
TOILET
1538A
STAIR
NO 04
I R READING
RM
1539A
COMMUNICATIONS
1538F
ANTE
RM
1538B
EQUIP RM
1538E
CONTROL RM - 3
1538D
SPECIAL
PROCEDURES
INTERVENTIONAL
1538C
STAIRWELL
VESTIBULE
VESTIBULE
CORRIDOR
CLOSET
SALLY
PORT
VESTIBULE
STEAM
STERILIZER
OPTICAL
WAITING RM
1538G
C1506B
1570A
C1506A
1521A
C1505
1555B
1635A
1602A
1410B
ATS RM
1570C
SUPERVISOR
OFFICE
POLICE
OFFICE
DAYLIGHT
WELL
MATCH LINEMATCH LINE
BLDG 1 - 1ST FLR PLAN - WEST -
PHASING & LIFE SAFETY
1-G101W
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
ISSUED FOR BIDS AND
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SECURITY CORRECTIONS
JESSE BROWN VAMC CHICAGO, IL
537-19-904
Project Director
08/06/21 J. Hirschhorn D. BrandtRevisions: Date:
PHASING
GENERAL NOTES
BUILDING 1 PHASED CONSTRUCTION KEY
NOTES - FIRST FLOOR - WEST
DOOR AND FRAME DELIVERY NOTES
DAYLIGHT
WELL
KEY PLAN
MATCH
LINE
MATCH
LINE
BLDG
BLDG
BLDG 1
WEST
BLDG
BLDG
WEST
BLDG
EAST
BLDG 1
EAST
AutoCAD SHX Text 0'
AutoCAD SHX Text
SCALE: 3/32"=1'-0"
AutoCAD SHX Text 32'
AutoCAD SHX Text 24'
AutoCAD SHX Text 16'
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text 1-G101W
AutoCAD SHX Text
AutoCAD SHX Text 3/32" = 1'-0"
AutoCAD SHX Text
BUILDING 1 - FIRST FLOOR PLAN - WEST
AutoCAD SHX Text 30A
AutoCAD SHX Text 30B
AutoCAD SHX Text 31A
AutoCAD SHX Text 31B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 17A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 38A
AutoCAD SHX Text
AutoCAD SHX Text 17B
AutoCAD SHX Text A. THIS IS A CONCEPTUAL PHASING PLAN. CONTRACTOR SHALL REVIEW THE THIS IS A CONCEPTUAL PHASING PLAN. CONTRACTOR SHALL REVIEW THE DRAWINGS AND SPECIFICATIONS AND INCLUDE PHASING IN HIS/HER BID IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. B. THE PRIMARY GOAL OF THIS PHASING DOCUMENT IS TO IDENTIFY THE THE PRIMARY GOAL OF THIS PHASING DOCUMENT IS TO IDENTIFY THE ADJACENCIES THAT WILL REQUIRE THE SEPARATE TIMING OF THE WORK ON PARTICULAR DOORS AGAINST NEARBY DOORS TO BE WORKED ON. WORK IN ALL PHASES WILL REQUIRE COORDINATION WITH HOSPITAL DEPARTMENTS (THROUGH THE COR) AS DOORS WITHIN THE PROJECT SCOPE IN CLOSE PROXIMITY CAN NOT BE WORKED ON SIMULTANEOUSLY. C. THE EXACT SEQUENCE OF WORK IS TO BE WORKED OUT THROUGH THE EXACT SEQUENCE OF WORK IS TO BE WORKED OUT THROUGH MEETINGS WITH COR AND AFFECTED HOSPITAL DEPARTMENTS. D. ANTICIPATED WORK AREAS ARE INDICATED TO PROVIDE FOR ON-GOING ANTICIPATED WORK AREAS ARE INDICATED TO PROVIDE FOR ON-GOING VAMC HEALTHCARE FUNCTIONS DURING CONSTRUCTION. THE CONSTRUCTION BARRIERS ARE IDENTIFIED AND LOCATED ON THE ARCHITECTURAL DRAWINGS (#.A100'S). E. CONSTRUCTION WORK WILL BE RESTRICTED TO OVERNIGHT AND WEEKEND CONSTRUCTION WORK WILL BE RESTRICTED TO OVERNIGHT AND WEEKEND HOURS (U.N.O.) AS STATED IN THE SPECIFICATIONS. F. COORDINATE AND SCHEDULE ALL WORK WITH THE COR. COORDINATE AND SCHEDULE ALL WORK WITH THE COR. G. PHASING WILL ALSO REQUIRE TEMPORARY ALTERNATE EMERGENCY EGRESS PHASING WILL ALSO REQUIRE TEMPORARY ALTERNATE EMERGENCY EGRESS ROUTES WHICH WILL BE INCLUDED IN PHASING KEY NOTES BELOW.
AutoCAD SHX Text (KEY NOTES APPLY TO THIS SHEET ONLY) 1. WORK ON EXTERIOR DOOR 02 AT LOADING DOCK HAS NO NEARBY DOOR WORK ON EXTERIOR DOOR 02 AT LOADING DOCK HAS NO NEARBY DOOR CONFLICTS. ACCESS TO LOADING DOCK WILL BE RE-ROUTED WHILE DOOR 02 IS WORKED ON. GC TO COORDINATE WITH COR (FOR LOADING DOCK DEPT. CONTACT) FOR TIMING OF CONSTRUCTION. 2. WORK ON EXTERIOR DOORS 15 & 16 AT ELECTRICAL ROOM 15E3 WILL ONLY WORK ON EXTERIOR DOORS 15 & 16 AT ELECTRICAL ROOM 15E3 WILL ONLY CONFLICT WITH EACH OTHER. GC TO WORK ON ONE DOOR AT A TIME. GC TO COORDINATE WITH COR (FOR FACILITIES DEPT. CONTACT) FOR TIMING OF CONSTRUCTION. 3. WORK ON EXTERIOR DOOR 17A AT VESTIBULE C1507 WILL CONFLICT WITH DOORS WORK ON EXTERIOR DOOR 17A AT VESTIBULE C1507 WILL CONFLICT WITH DOORS 17B,33,34&39 IN PUBLIC CORRIDORS. DOOR 17A PROVIDES EMERGENCY EGRESS FOR RADIOLOGY AND POLICE DEPT. OF BLDG 1 WEST. ANY DEPT'S IN THESE AREAS OPEN DURING WORK ON THIS DOOR WILL BE ROUTED THROUGH LOBBIES OF BUILDING 40. 4. WORK ON INTERIOR DOORS 30A&B BETWEEN CORRIDOR C1505 AND ENTRANCE WORK ON INTERIOR DOORS 30A&B BETWEEN CORRIDOR C1505 AND ENTRANCE LOBBY C1103 CONFLICTS WITH DOORS 31A&B. THESE DOORS ARE A PRIMARY PUBLICWAY. GC TO COORDINATE WITH COR (HOSPITAL ADMIN) FOR TIMING OF CONSTRUCTION. 5. WORK ON INTERIOR DOORS 31A&B BETWEEN CORRIDOR C1505 AND CORRIDOR WORK ON INTERIOR DOORS 31A&B BETWEEN CORRIDOR C1505 AND CORRIDOR C1504 CONFLICTS WITH DOORS 30A&B. THESE DOORS ARE A PRIMARY PUBLICWAY. GC TO COORDINATE WITH COR (HOSPITAL ADMIN) FOR TIMING OF CONSTRUCTION. 6. WORK ON INTERIOR DOORS 32 BETWEEN CORRIDOR C1504 AND WAITING 1515 IN WORK ON INTERIOR DOORS 32 BETWEEN CORRIDOR C1504 AND WAITING 1515 IN CT SUITE HAS CONFLICTS WITH DOORS 34&17A. IF DEPT. IS OPEN DURING WORK ON THIS DOOR, STAFF WILL BE ROUTED THROUGH CORRIDOR C1506 AND VESTIBULE C1507. 7. WORK ON INTERIOR DOOR 33 AT CORRIDOR C1509 WILL CONFLICT WITH DOOR 34 WORK ON INTERIOR DOOR 33 AT CORRIDOR C1509 WILL CONFLICT WITH DOOR 34 AT CORRIDOR C1506. IF RADIOLOGY DEPT IS OPEN DURING WORK ON THIS DOOR, STAFF WILL BE ROUTED THROUGH BUILDING 40. 8. WORK ON INTERIOR DOOR 34 AT CORRIDOR C1506 WILL CONFLICT WITH DOOR 33 WORK ON INTERIOR DOOR 34 AT CORRIDOR C1506 WILL CONFLICT WITH DOOR 33 AT CORRIDOR C1509. IF RADIOLOGY OR CT DEPT'S ARE OPEN DURING WORK ON THIS DOOR, STAFF WILL BE ROUTED THROUGH CORRIDOR C1505. 9. WORK ON EXTERIOR DOORS 35 & 36 AT SWITCHGEAR ROOM 15E5 WILL ONLY WORK ON EXTERIOR DOORS 35 & 36 AT SWITCHGEAR ROOM 15E5 WILL ONLY CONFLICT WITH EACH OTHER. GC TO WORK ON ONE DOOR AT A TIME. GC TO COORDINATE WITH COR (FOR FACILITIES DEPT. CONTACT) FOR TIMING OF CONSTRUCTION. 10. WORK ON EXTERIOR DOOR 37 AT STAIRWELL C1506B WILL CONFLICT WITH DOOR WORK ON EXTERIOR DOOR 37 AT STAIRWELL C1506B WILL CONFLICT WITH DOOR 36 AT SWITCHGEAR RM AND DOOR 38B ON FLOOR ABOVE. GC TO WORK ON ONE DOOR AT A TIME. GC TO COORDINATE WITH COR (FOR FACILITIES DEPT. CONTACT) FOR TIMING OF CONSTRUCTION. 11. WORK ON EXTERIOR DOOR 38A AT ATS ROOM 1570C HAS NO NEARBY DOOR WORK ON EXTERIOR DOOR 38A AT ATS ROOM 1570C HAS NO NEARBY DOOR CONFLICTS. GC TO COORDINATE WITH COR (FOR ATS CONTACT) FOR TIMING OF CONSTRUCTION. 12. WORK ON INTERIOR DOOR 39 BETWEEN CORRIDOR C11510 AND BUILDING 40 WILL WORK ON INTERIOR DOOR 39 BETWEEN CORRIDOR C11510 AND BUILDING 40 WILL CONFLICT WITH DOOR 17 AT VESTIBULE C1507. GC TO WORK ON ONE DOOR AT A TIME. GC TO COORDINATE WITH COR (FOR HOSPITAL ADMIN.) FOR TIMING OF CONSTRUCTION. 13. WORK ON EXTERIOR DOOR 17B AT STAIR NO.3 WILL CONFLICT WITH DOOR 17A. WORK ON EXTERIOR DOOR 17B AT STAIR NO.3 WILL CONFLICT WITH DOOR 17A. DOOR 17B PROVIDES EMERGENCY EGRESS FOR FLOORS ABOVE IN BLDG 1 WEST. ANY DEPT'S IN THESE AREAS OPEN DURING WORK ON THIS DOOR WILL BE ROUTED THROUGH LOBBIES OF BUILDING 40. 14. WORK ON INTERIOR DOOR 27 BETWEEN CORR'S C1505 & C1504 CONFLICTS WITH WORK ON INTERIOR DOOR 27 BETWEEN CORR'S C1505 & C1504 CONFLICTS WITH DOORS 32. THESE DOORS ARE A PRIMARY PUBLICWAY. WORK ON THIS DOOR WILL ALSO IMPACT MAIN ENTRY INTO POLICE. GC TO COORDINATE WITH COR (HOSPITAL ADMIN & POLICE) FOR TIMING OF CONSTRUCTION.
AutoCAD SHX Text
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY AND INSTALLATION THE CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY AND INSTALLATION MEANS AND METHODS FOR ALL NEW DOORS AND FRAMES TO THE WORK SITES THROUGHOUT THE BUILDING. 2. THE CONTRACTOR SHALL REVIEW THE DRAWINGS, SPECIFICATIONS AND THE CONTRACTOR SHALL REVIEW THE DRAWINGS, SPECIFICATIONS AND EXISTING BUILDING DRAWINGS TO DETERMINE DELIVERY ROUTES FOR THE DOORS AND FRAMES TO THE PROJECT WORK SITES THROUGHOUT THE BUILDING. THE CONTRACTOR SHALL PROVIDE DRAWINGS DEMONSTRATING THAT THE DELIVERY PATH IS ACCEPTABLE FOR REVIEW AND APPROVAL BY THE VA (COR) PRIOR TO PROCEEDING WITH DOOR AND FRAME DELIVERY INTO THE FACILITY. 3. THE DOOR AND FRAME DELIVERY TO THE PROJECT WORK SITE SHALL BE THE DOOR AND FRAME DELIVERY TO THE PROJECT WORK SITE SHALL BE SCHEDULED FOR SAME DAY INSTALLATION. STOCK PILING DOORS AND FRAMES WITHIN THE BUILDING WILL NOT BE PERMITTED UNLESS IT IS DEMONSTRATED TO BE ACCEPTABLE THROUGH THE REVIEW PROCEDURE NOTED ABOVE. 4. ALL EXISTING EXTERIOR AND INTERIOR FINISHES OR CONDITIONS DAMAGED ALL EXISTING EXTERIOR AND INTERIOR FINISHES OR CONDITIONS DAMAGED AS A RESULT OF THE DOOR AND FRAME DELIVERY SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING AT NO COST TO THE OWNER.
AutoCAD SHX Text
PLAN NORTH
TRUE NORTH
MATCH LINE MATCH LINE
TV
OCCUPATIONAL
THERAPY
2514A
TEL
24E2
STORAGE
FAC
2479A
ELECTRICAL
CLOSET
24E3
COAT CLOSET
2438C
STORAGE
2438A
TOILET
2438B
STORAGE
2440A
STORAGE
2447A
CONNECTING
CORRIDOR
C2307
ASSOCIATE
DIRECTOR
PATIENT
CARE
CORRIDOR
C2401
ELEVATOR
ELEVATOR
CORRIDOR
C2409
CORRIDOR
C2404
WOMENS
TOILET
2521A 2548
CORRIDOR
C2501
IRM STORAGE
WAITING RM
CORRIDOR
C2408
STORAGE
CANTEEN STORAGE
STORAGE
STORAGE
AUTOPSY
AREA
ELEVATOR
NO P4
ELEVATOR
NO P3
ELEVATOR
NO P2
ELEVATOR
NO P1
SOILED
UTILITY
TOILET/
SHOWER
2497A
MORGUE CLEAN UTILITY
REFR
2477A
2457MECH SPACE
VOLUNTARY
STORAGE
FLEET OPERATION
OFFICE
2449A
SUPV
OFFICE
2449B
ELEVATOR
NO P7
ELEVATOR
NO P8
PATIENT
ADVOCATE OFFICE
CORRIDOR
C2405
CONFERENCE RM
DIRECTORS STAFF
OFFICE AREA
2443 TELEPHONE
CLOSET
24T1
STAIR
NO 1
CORRIDOR
C2407
MENS TOILET
TEL
STAIR
NO 2
DIRECTOR
OFFICE
TOILET
2413B
STORAGE
2413A
ELECTRICAL
24E1
SECRET
AREA
LOUNGE /
KITCHEN
ASSOCIATE
DIRECTOR
SECRET
SECRET
PUBLIC
RELATIONS
STAFF
OFFICE
ASST TO
DIRECTOR
AUDITORIUM
ELECTRICAL
24E6
CORRIDOR
C2406
STAFF
ATTORNEY
MGR
ANALYST
SECY STAFF
OFFICE
DOCTOR
OFFICE
AD OFFICE
ACOS CLINIC
AFFAIRS
OFFICE
STORAGE
BREAK
RM
WOMENS
TOILET
COMPLIANCE
OFFICER
OFFICE
STORAGE
2446D
LOBBY
P I
OFFICE
ELECTRICAL
RECEPTION
2444A
VESTIBULE
MENS TOILET
STORAGE
2446A
WOMENS TOILET
UNISEX
TOILET
KITCHEN
2446B
CORRIDOR
C2402
STAIR
CORRIDOR
C2403
MECH SPACE
ELEVATOR
FAMILY VIEWING
TOILET
STORAGE
2492A
STAIR
NO 5
ELEVATOR
LAB
INJECTION
RM
PROCESSING
RM
ELECTRICAL
24E5
NUCLEAR MEDICINE
SCANNING AREA
TREATMENT RM
CHIEF OF STAFF
ASST
DIRECTOR
STORAGE
AND EQUIP
2446C
DRESSING RM
2462A
PIV
PIV
PIV
VISUAL
CO-ORDR
TOILET
2474A
LOW AND
BLIND VISION
TREATMENT RM
STRESS LAB
WAITING
CARDIOLOGY
TREATMENT
NUCLEAR
MED
RECEPTION
HAC
FILE RM
NUCLEAR
MED CHIEF
NUCLEAR MED
READING RM
BONE DENSITY
PROCEDURE RM
TECHNICAL
DIRECTOR
STAFF
OFFICE
M-1
NO 5A
2446H2446F 2446G
2554B
WALL PARTITION CLOSETWALL PARTITION CLOSET
FIRE
CLOSET
CLEAN
UTILITY
IRM STORAGEIRM
STORAGE
STORAGE
OFFICE
ASSOCIATE
DIRECTOR
ROOF
ROOF
ROOF
EMERGENCY
SUBSTATION
RM
2556B
VESTIBULE
NORMAL
SUBSTATION
RM
2556A
ELECTRICAL
CLOSET
24E4
CANTEEN
STORAGE
2505A
FIRE
CLOSET
DAYLIGHT
WELL
BLDG 1 EAST
BLDG 1 WEST
BLDG 1 - 2ND FLR PLAN - EAST -
PHASING & LIFE SAFETY
1-G102E
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
ISSUED FOR BIDS AND
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
SECURITY CORRECTIONS
JESSE BROWN VAMC CHICAGO, IL
537-19-904
Project Director
08/06/21 J. Hirschhorn D. BrandtRevisions: Date:
PHASING
GENERAL NOTES
BUILDING 1 PHASED CONSTRUCTION KEY
NOTES - SECOND FLOOR - EAST
DOOR AND FRAME DELIVERY NOTES
DAYLIGHT
WELL
KEY PLAN
MATCH
LINE
MATCH
LINE
BLDG 1
WEST
BLDG 1
EAST
BLDG
BLDG
BLDG
WEST
BLDG
EAST
AutoCAD SHX Text 0'
AutoCAD SHX Text
SCALE: 3/32"=1'-0"
AutoCAD SHX Text 32'
AutoCAD SHX Text 24'
AutoCAD SHX Text 16'
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
PLAN NORTH
AutoCAD SHX Text
TRUE NORTH
AutoCAD SHX Text 1-G102E
AutoCAD SHX Text
AutoCAD SHX Text 3/32" = 1'-0"
AutoCAD SHX Text
BUILDING 1 - SECOND FLOOR PLAN - EAST
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A. THIS IS A CONCEPTUAL PHASING PLAN. CONTRACTOR SHALL REVIEW THE THIS IS A CONCEPTUAL PHASING PLAN. CONTRACTOR SHALL REVIEW THE DRAWINGS AND SPECIFICATIONS AND INCLUDE PHASING IN HIS/HER BID IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. B. THE PRIMARY GOAL OF THIS PHASING DOCUMENT IS TO IDENTIFY THE THE PRIMARY GOAL OF THIS PHASING DOCUMENT IS TO IDENTIFY THE ADJACENCIES THAT WILL REQUIRE THE SEPARATE TIMING OF THE WORK ON PARTICULAR DOORS AGAINST NEARBY DOORS TO BE WORKED ON. WORK IN ALL PHASES WILL REQUIRE COORDINATION WITH HOSPITAL DEPARTMENTS (THROUGH THE COR) AS DOORS WITHIN THE PROJECT SCOPE IN CLOSE PROXIMITY CAN NOT BE WORKED ON SIMULTANEOUSLY. C. THE EXACT SEQUENCE OF WORK IS TO BE WORKED OUT THROUGH THE EXACT SEQUENCE OF WORK IS TO BE WORKED OUT THROUGH MEETINGS WITH COR AND AFFECTED HOSPITAL DEPARTMENTS. D.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .