This document contains a solicitation notice and statement of work for triennial high voltage electrical testing and maintenance services. The Department of Veterans Affairs Network Contracting Office 10 seeks a contractor to perform testing and calibration of electrical systems at the Northern Indiana Healthcare Systems facilities in Fort Wayne and Marion, Indiana in accordance with the attached statements of work. Services include testing, adjusting, calibrating, and inspecting equipment such as power transformers, switchgear, motor control centers, distribution centers, panel boards, air and vacuum circuit breakers, loop switches, and overcurrent relays. The contractor will be responsible for reinstalling all equipment to original condition and verifying voltage, phasing and rotation following testing. The government anticipates releasing the request for quote on August 24th with a response due date of September 6th. An optional site visit will be held on August 30th for offerors. The point of contact is listed for any questions.

View the file

Other files for this federal contract opportunity

Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOW Electrical Testing

ATTACHMENT 1

1. EQUIPMENT TO BE TESTED AT MARION CAMPUS

A. 15KV Substation located behind Bldg 76 3 each – vacuum breakers 4 each – air breakers 30 each – protective relays 1 system – Capacitor Bank 1 Each – Disconnect for Capacitor Bank

B. LOOP SWITCHES 15 KV to 480/277 or 240/120

14 Loop switches located throughout the campus

1 anti-paralleling loop switch in the substation

C. Pad Mounted oil-filled transformers

22 located throughout the campus

D. Dry-type transformer attachment 2

E. Battery Bank located at sub-station

26 Lead-Calcium cells

F. Low Voltage Breakers

9 Each – located in basement of Bldg 138

G. Distribution panels list provided below attachment 3

H. Motor Control Centers attachment 4

2022 Electric Test Maintenance Marion Ft Wayne_SOW.pdf
SOW for High Voltage Testing SOW Marion Ft Wayne.pdf
marion dry type transformers
Marion panel boards
Marion MCC
FT Wayne electrical test equipment list
EQ TO BE TESTED
Fort Wayne Electrical Panel list
All Panels