Attachment 03 - Sensitive Infrastructure Data Classification.pdf
PDF 492 KB Posted
- Attached to
- Z1DA-- 529-22-101 Replace Bldg. #7 Master Control Panel Federal contract opportunity
- Solicitation number
- 36C24424R0075
About this file
This document is a memorandum from the Department of Veterans Affairs (VA) that provides guidance on the classification and protection of sensitive infrastructure data related to VA-controlled facilities. It defines the types of infrastructure data that will be considered sensitive and marked as For Official Use Only (FOUO), including facility drawings, specifications, reports, and operations and maintenance data on critical or secure areas such as pharmacies, security systems, and IT rooms. The memorandum also references the VA's efforts to implement Controlled Unclassified Information (CUI) standards in accordance with Executive Order 13556.
The related federal contract opportunity is for the replacement of the master control panel in Building #7, which is being procured using a Best Value Lowest Price Technically Acceptable (LPTA) source selection approach. The solicitation provides detailed instructions for submitting proposals, including requirements related to format, content, and submission deadlines. The evaluation criteria focus on the offeror's experience with industrial construction, project phasing, managing critical facility operations, and handling long lead-time acquisitions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Drawings - Combined 2024-1101.pdf | ||
| Replace Bldg 7 Master Control Panel QA-Butler response editded for resubmission REVISED.docx | DOCX document | |
| 36C24424R0075 0004.docx | DOCX document | |
| Site Visit Sign In Boiler Plant 10-17.pdf | ||
| 36C24424R0075 0003.docx | DOCX document | |
| 36C24424R0075 0002.docx | DOCX document | |
| 36C24424R0075 0001.docx | DOCX document | |
| Boiler plant site visit 9-26.pdf | ||
| Wage Determination PA20240079 rev.7.19.24.pdf | ||
| Attachment 04 Butler VA HCS MCP.pdf | ||
| Attachment 02 - Specifications 9.12.24.pdf | ||
| VHA PCRA Boiler Plant.pdf | ||
| Attachment 01 - Drawings 7.12.24.pdf | ||
| 36C24424R0075_1.docx | DOCX document | |
| Replace Bldg 7 Master Control Panel QA-Butler response editded for resubmission.docx | DOCX document | |
| J and A Simplex redacted.pdf | ||
| Statement of Work - Project No. 529-22-101.pdf |
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Department of Veterans Affairs
D\ate: NOV O 7 2018
Memorandum
From: Deputy Under Secretary for Health for Operations and Management (1 ON)
Subj: Sensitive Infrastructure Data Classification - For Official Use Only (FOUO)
To: Veterans Integrated Service Network Directors (10N1-23)
1. This memorandum describes Veterans Health Administration's direction to protect sensitive infrastructure information, including building drawings and related data, for VHA-controlled space. VHA-controlled space includes owned, leased, and delegated Federal facil ities. All information determined to be sensitive shall be marked and managed as FOUO in accordance with this memorandum. This applies to the access to and generation, dissemination, storage, transfer and disposal of all FOUO information related to VHA-controlled space and to procurements to obtain, alter, or manage space, either Government-owned or leased, including VHA space that is delegated to other Federal agencies.
2. Executive Order 13556, signed on November 4, 2010, establishes a program for managing Controlled Unclassified Information, with the National Archives and Records Administration (NARA) serving as the executive agent. The Department of Veterans Affairs is in the process of developing Controlled Unclassified Information (CUI) standards in conformance with the Executive Order and NARA requirements. In advance of agency direction regarding the implementation of CUI, this memorandum specifically identifies and defines sensitive infrastructure information. Due to the increased use and transfer of electronic media it was determined that advance clarification of infrastructure data requirements is necessary. Data types that will be considered sensitive and therefore FOUO is as follows:
a. Facility drawings with technical details (e.g. cross-sections, construction details, wiring diagrams, etc.) on critical or secure areas.
b. Specifications with information on critical or secure areas, associated functions or systems.
c. Reports or investigations pertaining to facilities management or infrastructure containing information on critical or secure areas.
d. Facility Operation and Maintenance data (Preventative Maintenance records, Standard of Procedures. Maintenance and Operation manuals) on critical or secure areas.
Page2
Sensitive Infrastructure Data classification - For Official Use Only (FOUO)
3. Critical or secure areas shall include areas categorized as or like the following, at a minimum:
• Pharmacy vault and dispensing area;
• Agent cashier area;
• Police holding cells and weapons vault;
• National Continuity of Operations (COOP) centers as well as COOP facilities at each VAMC;
• National Emergency Response caches;
• Biological Safety Level - 3 laboratories;
• Security systems (Video Assessment and Surveillance System, Physical Access
Control System, Intrusion Detection System, etc.) and control centers;
• Information Technology room design details; and
• Animal research facility or laboratories.
4. If you have any questions, please feel free to contact Mr. Vincent Rizzo, Compliance Engineer, by phone at (716) 238-5587 or by email at Vincent.Rizzo@va.gov. In addition, please coordinate this guidance with your Network Capital Assets Manager and Medical Center Chief Engineers.