Attachment 03_Requirements_Submission_Matrix.xlsx
XLSX spreadsheet 13 KB Posted
- Attached to
- Divers Life Support System (DLSS) Routine Maintenance Services Federal contract opportunity
- Solicitation number
- N00244-25-R-0016
About this file
This is a Requirements Submission Matrix that outlines mandatory personnel and facility certifications required for providing Divers Life Support System (DLSS) maintenance services.
The contractor must employ certified staff including: a Precision Oxygen Cleaning worker, a certified technician for oxygen booster pumps, a D.O.T. designated hydrostatic test operator, and a certified technician for divers breathing air compressors. Facility requirements include: compliance with Hazmat and air quality control regulations, an approved Oxygen Instrument Calibration Room, an Oxygen Cleaning Facility (Class B) per MIL-STD-1330D CH1, calibration services accreditation per OPNAVINST 3960.16, ISO/IEC 17025:2005 or equivalent quality management certification, D.O.T. approved cylinder requalification facility, and appropriate Freon handling certifications. All facilities must maintain spaces free from environmental conditions that could impact DLSS cleanliness.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N00244-24-R-0016- 0004 .pdf | ||
| N00244-25-R-0016- 0003 DLSS.pdf | ||
| DLSS PWS Updated 1.23.pdf | ||
| OHA- Notice Order.pdf | ||
| N00244-25-R-0016-002.pdf | ||
| N00244-25-R-0016- 0001 Final.pdf | ||
| N00244-25-R-0016 .pdf | ||
| Attachment 02- OPPD.docx | DOCX document | |
| Exhibit A_CDRL 0001 - DLSS Monthly Status Report.pdf | ||
| Attachment 01_PWS.pdf | ||
| Attachment 04_QASP.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Attachment 3 - Contactor Requirements Submission Matrix | ||
| PWS Ref. | PWS Requirement | INSTRUCTIONS: Quoters shall provide the certifications or other information as part of its Technical Volume to demonstrate how its proposed approach meets the below requirements. In each line below, provide a brief statement of how the proposed approach meets the requirements and identify where the supporting information is contained in your Technical Volume. |
| Certifications/Approvals/Accreditations. The contractor shall have the following certifications/approvals/accreditations: | ||
| PERSONNEL: | ||
| 3.2.1 | Certified Precision Oxygen Cleaning worker (onsite), a minimum of one (1) employee. | |
| 3.2.2 | Certified technician for cleaning, operation, maintenance and repair of various oxygen booster pumps (IE: Haskell, Hydraulics International), a minimum of one (1) employee. | |
| 3.2.3 | D.O.T. designated hydrostatic test operator, a minimum of one (1) employee. | |
| 3.2.4 | Certified technician for retail service, maintenance and repair of divers breathing air compressors (IE: Bauer, Rix). A minimum of one (1) employee | |
| FACILITIES: | ||
| 3.2.5 | Hazmat and air quality control board requirements compliances in accordance with Federal, State and Local jurisdiction in which they are located. | |
| 3.2.6 | Oxygen Instrument Calibration Room. Approved by competent authority (IE: NAVSEA) | |
| 3.2.7 | Oxygen Cleaning Facility (Class B) IAW MIL-STD-1330D CH1. Approved by competent authority (IE: NAVSEA) | |
| 3.2.8 | Oxygen Cleaning Process IAW MIL-STD-1330D CH 1 for component, cylinder and piping/hose cleaning. Approved by competent authority (IE: NAVSEA) | |
| 3.2.9 | Calibration services accreditation IAW OPNAVINST 3960.16 | |
| 3.2.10 | ISO/IEC 17025:2005 or ANSI Z540.3 or ISO 9001:2015 or in-place Quality Management System that meets the intent of the standard | |
| 3.2.11 | D.O.T. approved cylinder requalification facility with Grade B water for conducting hydrostatic testing of oxygen cylinders | |
| 3.2.12 | Certifications and permits required to handle Freon for gauge cleaning affluent sampling as applicable at Federal, State and Local level | |
| 3.2.13 | Space free from exposure to dust, debris and other environmental conditions which would adversely impact the cleanliness of DLSS. |