The building exhibits an overall condition score of 60 (Unsatisfactory) with a Facility Condition Index (ERSL) rating of 7. Section A, comprising 34,082 square feet of built-up membrane roofing installed in 1998, has the lowest condition score of 50 and represents the most critical area, with wet insulation issues affecting 1,453 square feet requiring moisture analysis. Section B (2,292 SF metal roof, installed 2012) maintains adequate condition with a score of 90. Sections C, D, and E utilize modified bitumen systems installed in 2004 and 2012, with condition scores ranging from 69-75. The report identifies 12 primary defect groups requiring repairs totaling $11,605. Critical recommendations include moisture analysis for Section A ($5,400), employment of a qualified Stucco/EIFS contractor for wall repairs in Section C ($2,640), metal flashing repositioning ($495), and open seam repair using fabric and mastic ($1,650). Additional minor repairs address downspout damage, debris removal, loose fasteners, and splash block installation. The building is scheduled for complete renovation, and copious debris and abandoned equipment require removal prior to re-roofing work.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Condition Assessment Report
Prepared for Shaw AFB
Building:
01130-HQ Numbered AF Shaw AFB Sumter, SC 29152
Date inspected 07/27/2022
1595028058C Text Box
FOR INFORMATION ONLY
This page intentionally left blank.
01130-HQ Numbered AF Shaw AFB pg 1
Site Information Site Name: 01130-HQ Numbered AF
Site Tag:
Site Address: Shaw AFB
Sumter, SC 29152 Region:
Area (Sq. Ft.): 64,459 Building Description:
Roof Access: Hatch Floors: Multi
Inspection Notes:
Client Contact: TBD Phone: TBD Email: TBD
Section Material Type Total Area
(Sq. Ft.)
Condition Score ERSL
A Built-up membrane 34,082 50 3 B Metal 2,292 90 25 C Modified bitumen 1,508 69 10 D Modified bitumen 596 75 12 E Modified bitumen 25,981 70 10
TOTALS (Avg.) 64,459 60 7
Recommended Repairs
Map Link
Defect Group
Defect Sec Recommendation Defect Count (Qty U/M)
Estimate
Map 1 Moisture - Wet insulation
A Moisture analysis required.
(1453 SF)
$5,400
Map 2 Line defect - see notes - Medium severity
C Employ a qualified Stucco / EIFS contractor to repair damaged area.
(80 LF)
$2,640
Map 3 Metal flashing defects (LF) - No water penetration
C Reposition sheet metal counter flashing to original position, secure and seal.
(82 LF)
$495 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=64&wbssevid=3&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=117&wbssevid=2&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=461&wbssevid=5&defstatus=2 pg 2
Map 4 Flashing slippage/delaminati on - Deliamination/slippi ng; no water penetration
A Repair open seams with fabric, mastic and granules in a three-course fashion.
(154 LF)
$1,650
Map 5 Downspout damage
- Loose or missign fasteners
C Reinstall downspout to original position and properly anchor to wall system.
(2 EA)
$660
Map 6 Debris (EA) - Loose or light weight debris
C Remove materials / equipment / debris and properly dispose / store offsite.
(2 EA)
$330
Map 7 Exposed fastener defects (LF) - Loose fasteners (20-50 total)
C Remove and replace loose / missing / corroded fasteners with new proper sized grommeted fasteners.
(84 LF)
$245
Map 8 Splash block defects
- Damaged splash block
C Supply and install splash block at downspout outlet.
(1 EA)
$185
BUILDING TOTAL 12
$11,605 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=462&wbssevid=2&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=474&wbssevid=1&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=548&wbssevid=1&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=555&wbssevid=2&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=560&wbssevid=1&defstatus=2 pg 3
Inventory Plan pg 4
Defect Plan pg 5
Section Summary - A
Section ID: A Type: Roof: Built-up membrane Area: 34,082 SF Layers:
● Surface:
○ Surface: Aggregate
● Membrane:
○ Adhesive: Asphalt
○ Adhesive: Coal tar
● Insulation:
○ Type: Perlite cover board
○ Thickness: See notes
● Deck:
○ Type: Cast in-place concrete
Year Installed: 1998 Height: 45 FT Sensitivity: Low Warranty Expiration: n/a Warranty Type: n/a Condition Score: 50 (Unsatisfactory)
Notes: Prior RCS=58; prior ERSL React/Proact=6/0. Prior RCS=53; prior ERSL React/Proact=2/0. building scheduled for complete renovation. Did not remove copious debris as per Tsgt Maldonado. Much abandoned equip to remove before re-roof. Few active leaks due to concrete deck pg 6
Section A Inventory
Inventory Attributes Quantity UOM
Roof assembly: BUR surface Surface: Aggregate 34,032 SF
Roof assembly: BUR membrane Adhesive: Asphalt; Adhesive: Coal tar 34,032 SF
Roof assembly: BUR insulation Type: Perlite cover board; Thickness:
See notes
34,032 SF
Roof assembly: BUR deck Type: Cast in-place concrete 34,032 SF
Perimeter: Parapet membrane flashing Type: Composite; Attachment:
Adhered; Stretch out: 12"
50 LF
Perimeter: Parapet membrane flashing Type: Composite; Attachment: Adhered 938 LF
Perimeter: Parapet counter flashing Type: Reglet - 1 piece 938 LF
Perimeter: Parapet counter flashing Type: Surface mount 50 LF
Perimeter: Gravel stop 294 LF
Perimeter: Coping cap Material: Painted steel; Width: 16" 988 LF
Perimeter: Segment Type: Parapet 988 LF
Perimeter: Segment Type: Edge 294 LF
Interior perimeter: Wall Type: Block - CMU; Height: 8' 32 LF
Interior perimeter: Wall membrane flashing Type: Roof; Attachment: Adhered 92 LF
Interior perimeter: Segment (interior) Type: Joint 256 LF
Interior perimeter: Segment (interior) Type: Wall 92 LF
Interior perimeter: Control joint Width: 6"; Type: With cap; Material:
Galvanized steel
228 LF
Penetrations: Pipe vent Size: 1.50"; Material: Cast iron; Flashing:
Membrane
11 EA
Penetrations: Curb (select size) Flashing: Membrane; Base height: 18";
Length: 2'; Width: 2'; Material: Wood
2 EA
Equipment: Exhaust fan/Extractor vent Type: Mechanized; Support: Curbed;
Base height: See notes; Length: See notes; Width: See notes; Unit height:
See notes
1 EA
Drainage: Field drain Size: < 4"; Material: Aluminum 25 EA
Drainage: Through-wall scupper 6 EA
Drainage: Through-wall scupper Type: Extruded polystyrene foam;
Width: 7"; Height: See notes; Length:
See notes; Material: Aluminum;
Downspout: Yes
1 EA
pg 7
Drainage: Through-wall scupper Width: See notes; Height: See notes;
Length: See notes; Material: See notes;
Finish: See notes; Downspout: Yes
1 EA
Drainage: Cricket (measure) 165 LF
Drainage: Slope Pitch: .25 : 12 93 LF
Assorted/Miscellaneous: Mounted bracket Size: 4' x 4' 2 EA pg 8
Section Summary - B
Section ID: B Type: Roof: Metal Area: 2,292 SF Layers:
● Metal surface:
○ Material: Steel
○ Type: Structural panel
○ Profile: Standing seam
○ Color: Beige
○ Coating: Kynar
○ Shape: Shed
Year Installed: 2012 Height: 25 FT Sensitivity: Low Warranty Expiration: n/a Warranty Type: n/a Condition Score: 90 (Adequate)
Notes: Prior RCS=95; prior ERSL React/Proact=28/0. Prior RCS=95; prior ERSL React/Proact=25/0.
pg 9
Section B Inventory
Inventory Attributes Quantity UOM
Roof assembly: Metal roof surface Type: Structural panel; Material: Steel;
Color: Beige; Coating: Kynar; Profile:
Standing seam; Shape: Shed
2,175 SF
Perimeter: Wall membrane flashing Type: Roof; Attachment: Fastened 67 LF
Perimeter: Raised edge 38 LF
Perimeter: Raised edge Gutter: No 38 LF
Perimeter: Drip edge Gutter: No 67 LF
Perimeter: Segment Type: Wall 67 LF
Perimeter: Segment Type: Edge 143 LF
Drainage: Slope Pitch: See notes 11 LF pg 10
Section Summary - C
Section ID: C Type: Roof: Modified bitumen Area: 1,508 SF Layers:
● Surface:
○ Color: White
○ Surface: Aluminum
● Membrane:
○ Adhesive: Asphalt
● Surface:
○ Surface: Aggregate
Year Installed: 2004 Height: 20 FT Sensitivity: Low Warranty Expiration: n/a Warranty Type: n/a Condition Score: 69 (Degraded)
Notes: Prior RCS=80; prior ERSL React/Proact=16/0. Prior RCS=70; prior ERSL React/Proact=6/0.
pg 11
Section C Inventory
Inventory Attributes Quantity UOM
Roof assembly: BUR surface Surface: Aggregate 1,367 SF
Roof assembly: BUR membrane Adhesive: Asphalt 1,367 SF
Roof assembly: Mod bit surface Surface: Aluminum; Color: White 1,367 SF
Perimeter: Wall Type: EIFS; Height: 12'; Screen: No; Wall substrate: Plywood
94 LF
Perimeter: Wall membrane flashing Type: Roof; Attachment: Adhered;
Stretch out: 18"; Wall height: 1'; Wall matl: Wood
94 LF
Perimeter: Wall counter flashing Type: Surface mount 94 LF
Perimeter: Gravel stop Rise: Low 94 LF
Perimeter: Segment Type: Wall 94 LF
Perimeter: Segment Type: Edge 94 LF
Penetrations: Electrical line penetration Flashing: Pitch pocket; Size: 4";
Material: Galvanized steel
1 EA
Drainage: Field drain Size: < 4"; Material: Cast iron w/ strainer
2 EA
Drainage: Slope Pitch: .25 : 12 4 LF pg 12
Section Summary - D
Section ID: D Type: Roof: Modified bitumen Area: 596 SF Layers:
● Surface:
○ Surface: Granular
○ Color: White
● Membrane:
○ Application: Torch
○ # of plies: 1
● Insulation:
○ Type: Unknown
Height: 50 FT Sensitivity: Low Warranty Expiration: n/a Warranty Type: n/a Condition Score: 75 (Degraded)
Notes: Prior RCS=90; prior ERSL React/Proact=17/0.
pg 13
Section D Inventory
Inventory Attributes Quantity UOM
Roof assembly: Mod bit surface Surface: Granular; Color: White 312 SF
Roof assembly: Mod bit membrane Application: Torch; # of plies: 1 312 SF
Roof assembly: Mod bit insulation Type: Unknown 312 SF
Perimeter: Parapet Width: 12"; Height: 3'; Height (min): 1' 71 LF
Perimeter: Parapet membrane flashing Type: Roof; Attachment: Adhered;
Stretch out: 48"; Wall height: 3'
71 LF
Perimeter: Coping cap Material: Painted steel; Width: 12";
Interior face: 4"; Exterior face: 5"
71 LF
Perimeter: Segment Type: Parapet 71 LF
Drainage: Through-wall scupper Width: 16"; Height: 8"; Length: 10";
Material: Galvanized steel; Finish:
Prefinished; Downspout: Yes
1 EA
Drainage: Overflow scupper 1 EA
Drainage: Cricket (measure) 21 LF
Drainage: Downspout Material: Steel; Type: External wall;
Finish: Painted; Size: 5"; Height: 30';
Shape: Square
1 EA
Drainage: Slope Pitch: .50 : 12 4 LF pg 14
Section Summary - E
Section ID: E Type: Roof: Modified bitumen Area: 25,981 SF Layers:
● Surface:
○ Surface: Granular
○ Color: White
● Membrane:
○ Application: Torch
○ # of plies: 1
● Insulation:
○ Type: Unknown
Height: 50 FT Sensitivity: Low Warranty Expiration: n/a Warranty Type: n/a Condition Score: 70 (Degraded)
Notes: Prior RCS=80; prior ERSL React/Proact=14/0.
pg 15
Section E Inventory
Inventory Attributes Quantity UOM
Roof assembly: Mod bit surface Surface: Granular; Color: White 23,437 SF
Roof assembly: Mod bit membrane Application: Torch; # of plies: 1 23,437 SF
Roof assembly: Mod bit insulation Type: Unknown 23,437 SF
Perimeter: Parapet membrane flashing Type: Roof; Attachment: Adhered;
Stretch out: 48"
636 LF
Perimeter: Coping cap Material: Painted steel; Width: 24" 636 LF
Perimeter: Segment Type: Parapet 636 LF
Penetrations: Plumbing vent Size: 3"; Material: PVC; Flashing: Lead boot
2 EA
Penetrations: Plumbing vent Size: 4"; Material: PVC; Flashing: Lead boot
2 EA
Penetrations: Hatch (select size) Length: 3'; Width: 3'; Type: Access hatch; Base height: 8"; Material:
Stainless steel; Finish: None
1 EA
Penetrations: Pitch pan Type: Metal; Material: Stainless steel;
Height: 4"; Length: 6"; Width: 6"
4 EA
Penetrations: Curb (select size) Flashing: Membrane; Base height: 8";
Length: 1'; Width: 1'; Material: Wood
1 EA
Drainage: Overflow drain Size: 4" 10 EA
Drainage: Through-wall scupper Width: See notes; Height: 8"; Length:
30"; Material: Galvanized steel; Finish:
Prefinished; Downspout: Yes
10 EA
Drainage: Cricket (measure) 425 LF
Drainage: Slope Pitch: .50 : 12 30 LF
Drainage: Ridge Ridge vent: No 199 LF
Assorted/Miscellaneous: Mod bit 180 LF
Assorted/Miscellaneous: Sleepers Material: Wood; Size: See notes 20 LF pg 16
Defect List Map Link Defect
Group
Defect Section Recommendation Count (Qty U/M)
Estimate Repair Cost
Map 0 Patched or repaired areas - Patch exists Status: Recorded
A No action required at this time. Monitor and maintain.
(30773
SF)
$0
Map 1 Moisture - Wet insulation Status: Proposed
A Moisture analysis required.
(1453 SF)
$5,400
Map 2 Line defect - see notes - Medium severity Status: Proposed
C Employ a qualified Stucco / EIFS contractor to repair damaged area.
(80 LF)
$2,640
Map 0 Membrane aging - Medium severity Status: Recorded
C, E, A, D
No action required at this time. Monitor and maintain.
(54323
SF)
$0
Map 3 Metal flashing defects (LF) - No water penetration Status: Proposed
C Reposition sheet metal counter flashing to original position, secure and seal.
(82 LF)
$495
Map 4 Flashing slippage/delamination - Deliamination/slipping; no water penetration Status: Proposed
A Repair open seams with fabric, mastic and granules in a three-course fashion.
(154 LF)
$1,650
Map 0 Flashing seam or side lap defects (EA) - Missing lap edge sealant Status: Repaired
E BF REPAIR 1
(1 EA)
$0
Map 0 Flashing seam or side lap defects (EA) - Open > 1/2" into seam, no water penetration Status: Repaired
D BF REPAIR 2
(2 EA)
$0
Map 5 Downspout damage - Loose or missign fasteners Status: Proposed
C Reinstall downspout to original position and properly anchor to wall system.
(2 EA)
$660 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=6&wbssevid=4&defstatus=1 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=64&wbssevid=3&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=117&wbssevid=2&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=123&wbssevid=2&defstatus=1 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=461&wbssevid=5&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=462&wbssevid=2&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=472&wbssevid=1&defstatus=9 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=472&wbssevid=3&defstatus=9 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=474&wbssevid=1&defstatus=2 pg 17
Map 0 Membrane ridges - Noticeable, felts are not exposed Status: Recorded
A No action required at this time. Monitor and maintain.
(53 LF)
$0
Map 0 Ponding - Ponding in membrane field Status: Recorded
A No action required at this time. Monitor and maintain.
(720 SF)
$0
Map 0 Metal coated surface defect - 10% of coating is deteriorated Status: Recorded
B No action required at this time. Monitor and maintain.
(1876 SF)
$0
Map 6 Debris (EA) - Loose or light weight debris Status: Proposed
C Remove materials / equipment / debris and properly dispose / store offsite.
(2 EA)
$330
Map 7 Exposed fastener defects (LF)
- Loose fasteners (20-50 total) Status: Proposed
C Remove and replace loose / missing / corroded fasteners with new proper sized grommeted fasteners.
(84 LF)
$245
Map 8 Splash block defects - Damaged splash block Status: Proposed
C Supply and install splash block at downspout outlet.
(1 EA)
$185
Map 0 Deteriorated sealant - Highly deteriorated Status: Repaired
D BF REPAIR 1
(6 LF)
$0
TOTAL 26 $11,605
https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=485&wbssevid=2&defstatus=1 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=489&wbssevid=1&defstatus=1 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=508&wbssevid=1&defstatus=1 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=548&wbssevid=1&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=555&wbssevid=2&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=560&wbssevid=1&defstatus=2 https://client.roof-express.com/api/defectmap.html?id=307&roof=1&xoom=19&lat=33.9749024329027&lng=-80.4798141093234&bid=19724&inspectid=105072&wbsdefid=572&wbssevid=3&defstatus=9 pg 18
Defect Album Defect Group #: 0 Defect: 1 (30773 SF) Patched or repaired areas - Patch exists Recommendation: No action required at this time. Monitor and maintain.
Defect Group #: 1 Defect: 3 (1453 SF) Moisture - Wet insulation Recommendation: Moisture analysis required.
Defect Group #: 2 Defect: 1 (80 LF) Line defect - see notes - Medium severity Recommendation: Employ a qualified Stucco / EIFS contractor to repair damaged area.
pg 19
Defect Group #: 0 Defect: 4 (54323 SF) Membrane aging - Medium severity
Defect Group #: 3 Defect: 1 (82 LF) Metal flashing defects (LF) - No water penetration Recommendation: Reposition sheet metal counter flashing to original position, secure and seal.
Defect Group #: 4 Defect: 1 (154 LF) Flashing slippage/delamination - Deliamination/slipping; no water penetration Recommendation: Repair open seams with fabric, mastic and granules in a three-course fashion.
pg 20
Defect: 1 (1 EA) Flashing seam or side lap defects (EA) - Missing lap edge sealant Recommendation: BF REPAIR
Defect: 2 (2 EA) Flashing seam or side lap defects (EA) - Open > 1/2" into seam, no water penetration
Defect Group #: 5 Defect: 2 (2 EA) Downspout damage - Loose or missign fasteners Recommendation: Reinstall downspout to original position and properly anchor to wall system.
pg 21
Defect: 1 (53 LF) Membrane ridges - Noticeable, felts are not exposed
Defect: 3 (720 SF) Ponding - Ponding in membrane field
Defect: 1 (1876 SF) Metal coated surface defect - 10% of coating is deteriorated pg 22
Defect Group #: 6 Defect: 2 (2 EA) Debris (EA) - Loose or light weight debris Recommendation: Remove materials / equipment / debris and properly dispose / store offsite.
Defect Group #: 7 Defect: 1 (84 LF) Exposed fastener defects (LF) - Loose fasteners (20-50 total) Recommendation: Remove and replace loose / missing / corroded fasteners with new proper sized grommeted fasteners.
Defect Group #: 8 Defect: 1 (1 EA) Splash block defects - Damaged splash block Recommendation: Supply and install splash block at downspout outlet.
pg 23
Defect: 1 (6 LF) Deteriorated sealant - Highly deteriorated
| Site Information |
| Inventory Plan |
| Defect Plan |
| Section A Inventory |
| Section B Inventory |
| Section C Inventory |
| Section D Inventory |
| Section E Inventory |
| Section Summary - A |
| Defect List |
| Defect Album |
File details come from the government source that posted it. Updated .