Attachment 0003 - Appendix B - Project Drawings.pdf
PDF 5 MB Posted
- Attached to
- Repair by Replacement Lighting Building 299 Federal contract opportunity
- Solicitation number
- W519TC-25-R-A017
About this file
This document is a comprehensive set of electrical lighting design drawings and specifications for a repair by replacement project for normal and emergency lighting in Building 299 at Rock Island Arsenal, Illinois. The project involves extensive electrical work, including removing existing light fixtures and installing new LED lighting fixtures across multiple areas and floors of the building. The design drawings cover 35 separate lighting areas, with detailed demolition and new work plans for first floor, mezzanine, and basement levels, and include specific fixture schedules, electrical panel schedules, and lighting control sequences.
The project includes replacing existing light fixtures with new Lithonia LED fixtures ranging from 8,000 to 48,000 lumens, with various distribution types and mounting configurations. The lighting design incorporates advanced control features such as wireless network controls, dimming capabilities, occupancy sensors, and daylight harvesting. Emergency lighting will be installed in specific rooms like mechanical areas, corridors, and restrooms, using dedicated emergency light fixtures. The electrical design involves eight emergency lighting panels (ELP-1-299 through ELP-8-299) with careful load balancing and circuit management, and the lighting control sequences provide detailed operational instructions for different building spaces, including automatic and manual lighting controls based on occupancy and time schedules.
View the file
Other files for this federal contract opportunity
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-001
C O
VE
R
S H
EE
T
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
IN
G
R O
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
REPAIR BY REPLACMENT NORMAL AND EMERGENCY LIGHTING
BUILDING 299
ROCK ISLAND ARSENAL
ROCK ISLAND, IL
AutoCAD SHX Text
DRIVE
AutoCAD SHX Text
BECK AVENUE
AutoCAD SHX Text
BECK AVENUE
AutoCAD SHX Text
KINGSBURY AVE
AutoCAD SHX Text
HOBBS ST.
AutoCAD SHX Text
BUFFINGTON ST.
AutoCAD SHX Text
STREET
AutoCAD SHX Text
BENET AVENUE
AutoCAD SHX Text
AVENUE
AutoCAD SHX Text
CHESTNUT AVENUE
AutoCAD SHX Text
STREET
AutoCAD SHX Text
STREET EAST
AutoCAD SHX Text
STREET WEST
AutoCAD SHX Text
AutoCAD SHX Text
SECOND
AutoCAD SHX Text
THIRD
AutoCAD SHX Text
AutoCAD SHX Text
AMERICAN DISCOVERY TRAIL
AutoCAD SHX Text
AutoCAD SHX Text
20FL
AutoCAD SHX Text
AutoCAD SHX Text
FORT ARMSTRONG AVE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
68SN
AutoCAD SHX Text
AutoCAD SHX Text 70-G
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SWITA
AutoCAD SHX Text
SUBSB
AutoCAD SHX Text 81320
AutoCAD SHX Text
246CPY
AutoCAD SHX Text
STREET
AutoCAD SHX Text
STREET
AutoCAD SHX Text
RODMAN
AutoCAD SHX Text
AVENUE
AutoCAD SHX Text
PERSHING
AutoCAD SHX Text
EAST
AutoCAD SHX Text
ROCK
AutoCAD SHX Text
ISLAND
AutoCAD SHX Text
AVENUE
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
RODMAN
AutoCAD SHX Text
GILLESPIE
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PERSHING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
SOUTH
AutoCAD SHX Text
AVENUE
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
EAST
AutoCAD SHX Text
RODMAN
AutoCAD SHX Text
BECK
AutoCAD SHX Text
SYLVAN
AutoCAD SHX Text
DRIVE
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text L
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text
AVE
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
FIELD
AutoCAD SHX Text
MEMORIAL
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AVENUE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AVENUE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AVENUE
AutoCAD SHX Text
DYKE ROAD
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text L
AutoCAD SHX Text V
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text E
AutoCAD SHX Text
R.I. VIADUCT
AutoCAD SHX Text
CIRCLE
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
AutoCAD SHX Text
ACP SHELTER
AutoCAD SHX Text
FORT ARMSTRONG AVE.
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
275SN
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
AutoCAD SHX Text
KINGSBURY
AutoCAD SHX Text
FLAGLER
AutoCAD SHX Text
STREET
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
BAUMBECK AVENUE
AutoCAD SHX Text
PROJECT LOCATION
G-002
D R
AW
IN
G
IN
D
EX
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G DRAWING INDEX
DRAWING NUMBER DRAWING NAME
G-001 COVER SHEET
G-002 DRAWING INDEX
G-003 DRAWING INDEX
G-004 KEYMAPS
G-005 OFFICE AREAS - ROOM SCHEDULE
L-001 ELECTRICAL GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
L-002 ELECTRICAL KEYNOTES
LD-101 LIGHTING DEMOLITION - AREA 1
LD-102 LIGHTING DEMOLITION - AREA 2
LD-103 LIGHTING DEMOLITION - AREA 3
LD-104 LIGHTING DEMOLITION - AREA 4
LD-105 LIGHTING DEMOLITION - AREA 5
LD-106 LIGHTING DEMOLITION - AREA 6
LD-107 LIGHTING DEMOLITION - AREA 7
LD-108 LIGHTING DEMOLITION - AREA 8
LD-109 LIGHTING DEMOLITION - AREA 9
LD-110 LIGHTING DEMOLITION - AREA 10
LD-111 LIGHTING DEMOLITION - AREA 11
LD-112 LIGHTING DEMOLITION - AREA 12
LD-113 LIGHTING DEMOLITION - AREA 13
LD-114 LIGHTING DEMOLITION - AREA 14
LD-115 LIGHTING DEMOLITION - AREA 15
LD-116 LIGHTING DEMOLITION - AREA 16
LD-117 LIGHTING DEMOLITION - AREA 17
LD-118 LIGHTING DEMOLITION - AREA 18
LD-119 LIGHTING DEMOLITION - AREA 19
LD-120 LIGHTING DEMOLITION - AREA 20
LD-121 LIGHTING DEMOLITION - AREA 21
LD-122 LIGHTING DEMOLITION - AREA 22
LD-123 LIGHTING DEMOLITION - AREA 23
LD-124 LIGHTING DEMOLITION - AREA 24
LD-125 LIGHTING DEMOLITION - AREA 25
LD-126 LIGHTING DEMOLITION - AREA 26
LD-127 LIGHTING DEMOLITION - AREA 27
LD-128 LIGHTING DEMOLITION - AREA 28
LD-129 LIGHTING DEMOLITION - AREA 29
LD-130 LIGHTING DEMOLITION - AREA 30
LD-131 LIGHTING DEMOLITION - AREA 31
LD-132 LIGHTING DEMOLITION - AREA 32
LD-133 LIGHTING DEMOLITION - AREA 33
LD-134 LIGHTING DEMOLITION - AREA 34
LD-135 LIGHTING DEMOLITION - AREA 35
L-101 LIGHTING NEW WORK - AREA 1
L-102 LIGHTING NEW WORK - AREA 2
L-103 LIGHTING NEW WORK - AREA 3
DRAWING INDEX
DRAWING NUMBER DRAWING NAME
L-104 LIGHTING NEW WORK - AREA 4
L-105 LIGHTING NEW WORK - AREA 5
L-106 LIGHTING NEW WORK - AREA 6
L-107 LIGHTING NEW WORK - AREA 7
L-108 LIGHTING NEW WORK - AREA 8
L-109 LIGHTING NEW WORK - AREA 9
L-110 LIGHTING NEW WORK - AREA 10
L-111 LIGHTING NEW WORK - AREA 11
L-112 LIGHTING NEW WORK - AREA 12
L-113 LIGHTING NEW WORK - AREA 13
L-114 LIGHTING NEW WORK - AREA 14
L-115 LIGHTING NEW WORK - AREA 15
L-116 LIGHTING NEW WORK - AREA 16
L-117 LIGHTING NEW WORK - AREA 17
L-118 LIGHTING NEW WORK - AREA 18
L-119 LIGHTING NEW WORK - AREA 19
L-120 LIGHTING NEW WORK - AREA 20
L-121 LIGHTING NEW WORK - AREA 21
L-122 LIGHTING NEW WORK - AREA 22
L-123 LIGHTING NEW WORK - AREA 23
L-124 LIGHTING NEW WORK - AREA 24
L-125 LIGHTING NEW WORK - AREA 25
L-126 LIGHTING NEW WORK - AREA 26
L-127 LIGHTING NEW WORK - AREA 27
L-128 LIGHTING NEW WORK - AREA 28
L-129 LIGHTING NEW WORK - AREA 29
L-130 LIGHTING NEW WORK - AREA 30
L-131 LIGHTING NEW WORK - AREA 31
L-132 LIGHTING NEW WORK - AREA 32
L-133 LIGHTING NEW WORK - AREA 33
L-134 LIGHTING NEW WORK - AREA 34
L-135 LIGHTING NEW WORK - AREA 35
L-401 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-402 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-403 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-404 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-405 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-406 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-407 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-408 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-409 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-410 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-411 LIGHTING NEW WORK - PARTIAL FIRST FLOOR PLAN
L-412 LIGHTING NEW WORK - PARTIAL MEZZANINE FLOOR PLAN
L-413 LIGHTING NEW WORK - PARTIAL MEZZANINE FLOOR PLAN
L-414 LIGHTING NEW WORK - PARTIAL BASEMENT PLAN
CONTINUED ON SHEET G-003
G-003
R
AW
IN
G
IN
D
EX
A N
D G
EN
ER
AL
C
O N
ST
R
U C
TI
O
N N
O
TE
S
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G DRAWING INDEX
DRAWING NUMBER DRAWING NAME
L-601 EXISTING LIGHT FIXTURE SCHEDULES
L-602 EXISTING LIGHT FIXTURE SCHEDULES
L-603 EXISTING LIGHT FIXTURE SCHEDULES
L-604 EXISTING LIGHT FIXTURE SCHEDULES
L-605 NEW LIGHT FIXTURE SCHEDULES
L-606 EMERGENCY LIGHTING PANEL SCHEDULES
L-607 EMERGENCY LIGHTING PANEL SCHEDULES
L-608 EMERGENCY LIGHTING PANEL SCHEDULES
L-609 EMERGENCY LIGHTING PANEL SCHEDULES
L-610 LIGHTING CONTROL SEQUENCES
GENERAL CONSTRUCTION NOTES
1. NOTES FOUND ON G-SHEETS, ARE GENERAL NOTES AND APPLY TO THE ENTIRE PROJECT TO
INCLUDE THE COMPLETE PLAN SET AND SPECIFICATIONS, UNLESS NOTED OTHERWISE. SHEET
NOTES APPLY TO ALL PLANS, ELEVATIONS, SECTIONS, AND DETAILS FOR THAT SHEET, UNLESS
NOTED OTHERWISE. KEYNOTES APPLY TO ELEMENTS ON THE SHEET AS INDICATED, UNLESS
NOTED OTHERWISE.
2. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT
INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE
AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
3. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT
DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR IMPLIED
THEREFROM.
4. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK SO
THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.
5. THE CONTRACTOR SHALL PROTECT ANY EXISTING, IN-PLACE, AND/OR NEW WORK.
6. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND LEGAL DISPOSAL OF
MATERIALS AND RUBBISH.
7. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. DIMENSIONS AND PLANS ARE NOT
WARRANTED AS ACCURATE. VERIFY EXISTING CONDITIONS THAT MAY AFFECT THE WORK
PRIOR TO BID.
8. DO NOT SCALE DRAWINGS; LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS.
9. NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, AND ALTERATION OPERATIONS
SHALL BE APPLIED.
10. DO NOT CUT INTO, REMOVE, OR ALTER ANY STRUCTURAL MEMBER OR FLOOR SYSTEM
UNLESS IT IS SPECIFICALLY NOTED OR SHOWN ON DRAWINGS.
11. THE CONTRACTOR SHALL PLAN THEIR WORK TO PROVIDE ADEQUATE PROTECTION FOR
PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE THE WORK IN SUCH A MANNER TO
AVOID ANY HAZARD TO PERSONS AND PROPERTY AS NECESSARY.
12. ALL PRODUCTS LISTED ON DRAWINGS AND NOT INDICATED IN SPECIFICATIONS SHALL BE
SUBMITTED FOR GOVERNMENT APPROVAL. CONTRACTOR SHALL ADD THESE TO THEIR
SUBMITTAL REGISTER. PRODUCTS LISTED ON DRAWINGS TAKE PRECEDENCE OVER
SPECIFICATIONS.
13. DEMOLITION OR NEW WORK MAY NOT BE SOLELY INDICATED ON THEIR CORRESPONDING
SHEETS, BUT MAY BE REQUIRED FOR WORK TO BE PERFORMED.
14. CONTRACTOR SHALL COORDINATE PARKING, JOB TRAILER, STAGING AND OTHER NECESSARY
SPACES WITH C.O.R. AND FACILITY MANAGER.
15. DISPOSE OF DEMOLISHED AND WASTE MATERIALS OFF SITE UNLESS OTHERWISE NOTED.
16. TO PERFORM THE WORK AS AWARDED BY THE BASE BID, OPTION, OR CONTRACT
MODIFICATION, THE CONTRACTOR SHALL EITHER PROTECT OR RELOCATE ADJACENT ITEMS,
EQUIPMENT, AND STRUCTURES AS NECESSARY TO FACILITATE THE WORK.
17. IN ORDER TO MORE CLEARLY DEPICT WORK BEING IDENTIFIED ON A DRAWING, ITEMS NOTED
AS BEING INCLUDED IN THE WORK ARE GENERALLY SHOWN IN HEAVY (BOLD) LINE WEIGHT
AND BLACK LINE WORK. GRAY SCALE LINE WORK DENOTES EXISTING CONDITIONS. NOTE:
THERE ARE EXCEPTIONS TO THIS RULE AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO
THOROUGHLY REVIEW DRAWINGS AND REQUEST ADDITIONAL INFORMATION PRIOR TO
BIDDING.
18. THE CONTRACTOR SHALL MAKE REQUESTS TO DISCONNECT POWER OR UTILITIES PER
SPECIFICATIONS. ALL WORK REQUIRING POWER REMOVAL SHALL BE DONE IN A TIMELY
MANNER AND OUTSIDE NORMAL INSTALLATION WORKING HOURS WHEN POSSIBLE. IF SAFE
WORKING CONDITIONS EXIST FOR BOTH THE CONTRACTOR AND BUILDING OCCUPANTS, THEN
POWER SHALL BE RESTORED FOR BUILDING OCCUPANTS DURING NORMAL WORKING HOURS.
THE CONTRACTOR SHALL IMMEDIATELY RESTORE POWER ONCE WORK IS COMPLETE AND
SAFE CONDITIONS EXIST.
19. THE CONTRACTOR SHALL OBTAIN NECESSARY BUILDING AND FIRE PERMITS FROM THE
INSTALLATION AUTHORITIES HAVING JURISDICTION.
20. THE CONTRACTOR SHALL COMPLY WITH INSTALLATION POLICIES AND PROCEDURES.
21. THE CONTRACTOR SHALL PERFORM WORK IN ACCORDANCE WITH APPLICABLE CODES,
ORDINANCES, AND REGULATORY AGENCIES.
22. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS ARE
TO BE REVIEWED AND NOTES ON INDIVIDUAL SHEETS SHALL BE APPLIED TO RELATED
DRAWINGS AND DETAILS.
23. ALL WORK SHALL BE DONE IN A WORKMAN LIKE MANNER. WORK SHALL CONFORM TO
APPLICABLE INDUSTRY OR MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF
MATERIALS AND WORKMANSHIP, AS WELL AS, ALL REQUIREMENTS IN THESE DRAWINGS AND
SPECIFICATIONS. ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL
BE BROUGHT TO THE ATTENTION OF THE C.O.R. PRIOR TO PROCEEDING WITH THE WORK.
G-004
KE
Y
M
AP
S
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72
B
C
D
E
F
G
H
K
L
M
N
P
R
RR
PP
NN
MM
LL
KK
HH
GG
FF
EE
DD
CC
BB
AA
AREA 1 AREA 2 AREA 3 AREA 4 AREA 5 AREA 6 AREA 7
AREA 8 AREA 9 AREA 10 AREA 11 AREA 12 AREA 13 AREA 14
AREA 15 AREA 16 AREA 17 AREA 18 AREA 19 AREA 20 AREA 21
AREA 22 AREA 23 AREA 24 AREA 25 AREA 26 AREA 27 AREA 28
AREA 29 AREA 30 AREA 31 AREA 32 AREA 33 AREA 34 AREA 35
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72
B
C
D
E
F
G
H
K
L
M
N
P
R
RR
PP
NN
MM
LL
KK
HH
GG
FF
EE
DD
CC
BB
AA
L-401
L-402 L-403
L-402
L-404 L-404 L-405
L-404
L-405
L-406 L-406
L-407 L-407
L-408
L-408 L-408 L-409 L-409
L-410
L-411 L-411 L-411
L-411
L-411
A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72
B
C
D
E
F
G
H
K
L
M
N
P
R
RR
PP
NN
MM
LL
KK
HH
GG
FF
EE
DD
CC
BB
AA
MECHANICAL
IT
ELECTRICAL
L-413
L-413L-412
L-410
AutoCAD SHX Text
VENDING MACHINES
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
%%UFLOOR PLAN AREA DESIGNATIONS
AutoCAD SHX Text N
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
%%UMEZZANINE KEYMAP
AutoCAD SHX Text N
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
%%UFIRST FLOOR KEYMAP
N
G-005
EN
ER
AL
R O
O M
N U
M
BE
R S
AN
D
R O
O M
D
ET
AI
LS
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
ROOM SCHEDULE
ROOM NUMBER ROOM NAME CEILING TYPE CEILING HEIGHT
001 BREAK LAY-IN TILE 9'10"
002 CLASSROOM LAY-IN TILE 9'10"
003 CLASSROOM LAY-IN TILE 9'10"
004 STORAGE LAY-IN TILE 9'10"
005 CORRIDOR LAY-IN TILE 9'10"
006 JANITOR LAY-IN TILE 9'10"
007 CONFERENCE LAY-IN TILE 9'10"
008 WAITING LAY-IN TILE 9'10"
009 MEETING LAY-IN TILE 9'10"
010 CORRIDOR LAY-IN TILE 9'10"
011 CORRIDOR GYPSUM BOARD 8'0"
012 WOMENS GYPSUM BOARD 8'0"
013 SHOWER GYPSUM BOARD 8'0"
014 MENS GYPSUM BOARD 8'0"
015 SHOWER GYPSUM BOARD 8'0"
016 CORRIDOR GYPSUM BOARD 8'0"
017 MECHANICAL LAY-IN TILE 9'10"
019 OFFICE LAY-IN TILE
020 OFFICE LAY-IN TILE
021 NOT USED
022 NOT USED
023 MECHANICAL
024 IT LAY-IN TILE
025 TENANT LAY-IN TILE
026 OFFICE LAY-IN TILE 8'0"
027 OFFICE LAY-IN TILE 8'0"
029 OFFICE LAY-IN TILE 9'0"
030 LAMINATING LAY-IN TILE 16'0"
031 RUBBER ROOM LAY-IN TILE
032 SPRINKLER RM
033 STORAGE LAY-IN TILE 9'0"
034 OFFICE LAY-IN TILE 9'0"
035 OFFICE LAY-IN TILE 9'0"
036 CORRIDOR LAY-IN TILE 9'0"
037 OFFICE LAY-IN TILE 9'0"
038 OFFICE LAY-IN TILE 9'0"
039 OFFICE LAY-IN TILE 9'0"
040 CONFERENCE RM LAY-IN TILE 9'0"
041 OFFICE
042 BREAKROOM LAY-IN TILE
043 RESTROOM GYP BOARD
044 RESTROOM GYP BOARD
045 OFFICE
046 OFFICE
047 IT CLOSET
048 STORAGE
049 CONFERENCE RM LAY-IN TILE
050 RESTROOM GYP BOARD
051 JANITOR GYP BOARD
052 RESTROOM GYP BOARD
053 OFFICE
054 BREAKROOM LAY-IN TILE
055 CONFERENCE RM LAY-IN TILE
056 OFFICE
057 OFFICE
058 ENTRY
059 ??
060 OFFICE
061 OFFICE
062 OPEN OFFICE
063 OFFICE
064 OFFICE
065 OFFICE
066 OFFICE
067 OFFICE
ROOM SCHEDULE
ROOM NUMBER ROOM NAME CEILING TYPE CEILING HEIGHT
068 OPEN OFFICE
069 OFFICE
070 OFFICE
071 OFFICE
072 OFFICE
073 PAINT STORAGE
074 CONFERENCE
075 OFFICE
076 BREAKROOM
077 OFFICE
078 OFFICE
079 MECHANICAL
080 CORRIDOR
081 OFFICE
082 OFFICE
083 STORAGE
084 ELECTRICAL
085 CORRIDOR
086 OFFICE
087 OFFICE
088 OFFICE
089 OFFICE
090 OFFICE
091 RESTROOM
092 RESTROOM
093 JANITOR
094 OFFICE
095 RESTROOM
096 RESTROOM
097 MUSEUM
098 OFFICE
099 PUMP ROOM
100 OFFICE
101 BREAKROOM
102 LOCKER/SHOWER
103 JANITOR
104 LOCKER/SHOWER
105 OFFICE
106 OFFICE
107 OFFICE
108 OFFICE
109 OFFICE
110 OFFICE
111 LAB
112 MECHANICAL
113 OFFICE
114 RESTROOM
115 JANITOR
116 OFFICE
117 OFFICE
118 OFFICE
119 OFFICE
120 OFFICE
121 RESTROOM
122 RESTROOM
123 OFFICE
124 OFFICE
125 ??
126 ??
ROOM SCHEDULE
ROOM NUMBER ROOM NAME CEILING TYPE CEILING HEIGHT
201 MECHANICAL - - -
202 IT LAY-IN TILE 8'0"
203 ELECTRICAL LAY-IN TILE 8'0"
L-001
EL
EC
TR
IC
AL
G
EN
ER
AL
N O
TE
S, S
YM
BO
LS
A N
D
AB
BR
EV
IA
TI
O N
S
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
ELECTRICAL GENERAL NOTES
1. ELEVATIONS INDICATED ON SYMBOL SCHEDULE AND PLANS ARE NOMINAL. INSTALL TO
NEAREST BLOCK COURSING, TO CLEAR EQUIPMENT OR AS NOTED.
2. SWITCHES AND OPERATING DEVICES SHALL NOT BE INSTALLED HIGHER THAN 48", IN
COMPLIANCE WITH HANDICAP CODE REQUIREMENTS WHERE APPLICABLE. RECEPTACLES,
TELEPHONE OUTLETS AND OTHER POWER AND COMMUNICATION OUTPUT DEVICES SHALL NOT
BE INSTALLED LOWER THAN 18", IN COMPLIANCE WITH HANDICAP CODE REQUIREMENTS WHERE
APPLICABLE.
3. INSTALL SEPARATE GREEN GROUND WIRE FROM GROUND TERMINAL ON ALL GROUNDED
RECEPTACLES TO BACKBOX EXCEPT ISOLATED GROUND RECEPTACLES. SELF-GROUND CLIP IS
NOT ACCEPTABLE.
4. TERMINALS ON WIRING DEVICES (HOT OR NEUTRAL) SHALL NOT BE USED FOR FEED-THROUGH
CONNECTIONS, LOOPED OR OTHERWISE. CIRCUIT CONNECTIONS SHALL BE MADE VIA WIRE
CONNECTORS AND PIGTAILS.
5. CONDUCTOR AMPACITY IS BASED ON 90 DEGREES C RATING, WHERE CONDUCTOR SIZES ARE
NOT NOTED ON PLAN OR RISER, THEY SHALL BE SIZED TO MATCH THE RATING OF THE
OVERCURRENT PROTECTIVE DEVICE AND IN ACCORDANCE WITH ABOVE.
6. BRANCH CIRCUIT CONDUIT RUNS: MAXIMUM 3/4 INCH WITH MAXIMUM 9 #12 AWG-THWN/THHN (MAXIMUM 1 INCH WITH MAXIMUM 9 #10 AWG-THWN/THHN). NO MULTIPLE BRANCH CIRCUITS IN NEW CONDUIT RUNS UTILIZING MORE THAN 9 WIRES IN A CONDUIT RUN SO THAT HALF OF THE ALLOWABLE FILL SPACE IS AVAILABLE FOR ADDING WIRES IN THE FUTURE. CONTRACTOR SHALL
NOT UTILIZE CONDUITS LARGER THAN 3/4 INCH FOR #12 BRANCH CIRCUIT CONDUIT RUNS (1
INCH FOR #10 WHERE APPLICABLE) AS A MEANS OF CONVEYING A LARGE NUMBER OF CIRCUITS
FROM THE PANELBOARD TO A GIVEN USE ARE OR FOR USE WITHIN ANY AREA.
7. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL BRANCH CIRCUIT WIRING IN
ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, THE PROJECT PLANS AND
SPECIFICATIONS. MAXIMUM LOAD PER 20A/1P CIRCUIT SHALL BE 1920 WATTS AT 120V AND 4400
WATTS AT 277V.
8. PROVIDE GREEN INSULATED GROUNDING CONDUCTOR IN ALL GREENFIELD CONNECTIONS TO
MOTORS, EQUIPMENT, AND LIGHT FIXTURES. HALF-INCH MINIMUM FLEX EXCEPT
MANUFACTURED FIXTURE WHIPS.
9. A JUNCTION BOX SHALL BE INSTALLED WHERE CHANGING FROM CONDUIT TO FLEXIBLE
RACEWAY.
10.INSTALL CONDUIT EXPANSION FITTINGS FOR ALL CONDUIT CROSSING EXPANSION JOINTS.
11.PANELBOARDS: PANEL FEEDERS TO BE BALANCED WITHIN 5% UNDER FULL LOAD CONDITIONS.
ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL REQUIREMENTS FOR MOTORS AND
EQUIPMENT BEFORE ORDERING BREAKERS FOR PANELBOARDS. CIRCUIT DIRECTORIES TO BE
PROPERLY FILLED IN WITH A TYPED DATA AT THE COMPLETION OF THE PROJECT. VERIFY
CIRCUIT DESIGNATIONS WITH THE CONTRACTING OFFICER'S REPRESENTATIVE. PROVIDE
MOUNTING HARDWARE ON ALL PANELBOARDS FOR SPACES INDICATED.
12.REMODELING, MODIFYING, PATCHING AND REPAIR OF EXISTING BUILDING COMPONENTS SHALL
BE DONE AS REQUIRED TO PRODUCT FINISHED WORK EQUAL TO THE NEW WORK AS SPECIFIED
AND DETAILED. CUTTING AND PATCHING SHALL BE THE RESPONSIBILITY OF THE TRADE WHOSE
WORK RESULTS IN THE NEED FOR CUTTING AND PATCHING, UNLESS A SPECIFIED CONTRACTOR
IS CALLED OUT ON THE DRAWINGS. CONTRACTOR SHALL COMPLETE ALL WORK NECESSARY TO
ACHIEVE THIS REQUIREMENT EVEN THOUGH PROCEDURES ARE NOT DETAILED AND/OR
SPECIFIED FOR EACH SPECIFIC CONDITION OR COMBINATION OF CONDITIONS. QUALITY OF
WORKMANSHIP, MATERIALS AND FINISH SHALL BE EQUAL TO THE LEVEL ESTABLISHED FOR
SIMILAR NEW WORK, EXCEPT WHERE EXISTING APPEARANCE IS TO BE MATCHED TO PROVIDE
CONTINUITY.
ELECTRICAL DEMOLITION NOTES
1. THE ELECTRICAL DEMOLITION DRAWING(S) SHOWING EXISTING CONDITION HAVE BEEN
PREPARED BASED ON FIELD OBSERVATION AND EXISTING DRAWINGS. ADDITIONAL
COMPONENTS MAY EXIST WHICH DO NOT SHOW, AND SUCH ITEMS SHALL BE DEALT WITH IN A
MANNER SIMILAR TO THOSE ITEMS WHICH DO SHOW.
2. CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING ELECTRICAL
SYSTEM(S) WHICH WILL BE AFFECTED BY THE DEMOLITION WORK. CONTRACTOR SHALL OBTAIN
PERMISSION FROM THE CONTRACTING OFFICER'S REPRESENTATIVE TO SHUT OFF SERVICES
OR SYSTEMS WHICH MAY AFFECT OTHER AREAS BEYOND THE LIMITS OF THE IMMEDIATE
DEMOLITION AREA.
3. PANELBOARDS, DISCONNECTS, FIXTURES, WIRING DEVICES, SIGNAL DEVICES, ETC., SHOWN ON PLANS SHALL BE REMOVED UNLESS NOTED WITH "P" IN WHICH CASE THE EXISTING EQUIPMENT
SHALL REMAIN. WHEN REMOVAL OF EXISTING MATERIALS CAUSES VOIDS IN EXISTING COVER
PLATES OR UNCOVERED JUNCTION BOXES, ETC., PROVIDE SOLID FINISHED COVERS THAT
PROTECT THE VOID OR OPENING AND MATCH THE SURROUNDING AREAS AS CLOSELY AS
POSSIBLE AND AS APPROVED BY THE CONTRACTING OFFICER'S REPRESENTATIVE.
4. UNLESS NOTED OTHERWISE, ALL FIXTURES, PANELBOARDS, DISCONNECTS, CONDUIT, OLD
BOXES, WIRING AND MISCELLANEOUS ELECTRICAL SCRAP SHALL BE REMOVED FROM THE
JOBSITE BY THE ELECTRICAL CONTRACTOR.
5. WHERE DEVICES ARE OMITTED FROM PRESENT BRANCH CIRCUITS, THE REMAINING DEVICES
SHALL BE REWIRED, IF NEEDED AND AS REQUIRED, TO REMAIN ON THEIR RESPECTIVE CIRCUITS
AND IN OPERATING CONDITION.
6. REMOVED PIPE AND WIRE SHALL NOT BE REUSED. AT CONTRACTOR'S OPTION, EXISTING
CONDUIT AND WIRING MAY BE REUSED IF NOTE REMOVED. CONDUIT AND WIRE THAT IS BEING
REUSED SHALL BE TESTED FOR CONTINUITY OF CONDUCTORS AND GROUND FOR INSULATION
RESISTANCE OF CONDUCTOR AND SPLICES.
7. WITH APPROVAL OF THE CONTRACTING OFFICER'S REPRESENTATIVE, MAKE MINOR
MODIFICATIONS IN THE WORK, INCLUDING REROUTING AS REQUIRED BY INTERFERENCES WITH
STRUCTURAL, GENERAL AND WORK OF OTHER TRADES OR FOR THE PROPER EXECUTION OF
THE WORK.
BASIC ELECTRICAL ABBREVIATIONS
MARK DESCRIPTION MARK DESCRIPTION
A AMPERES
AFF ABOVE FINISHED FLOOR
C CONDUIT
CEB CONCRETE EQUIPMENT BASE
CKT CIRCUIT
EMT ELECTRICAL METALLIC TUBING
FLA FULL LOAD AMPS
G GROUND
MOCP MAXIMUM OVERCURRENT PROTECTION
NC NEW CONNECTION
PC PHOTOCELL
PNL PANEL
RECEPT RECEPTACLE
TC TIME CLOCK
TYP TYPICAL
V VOLTS
VL VERIFY LOCATION
W WATTS
W / WITH
XFMR TRANSFORMER
ELECTRICAL SYMBOLS
LIGHTING FIXTURES, ETC.
SYMBOL DESCRIPTION
EMERGENCY BATTERY FIXTURE, WALL MOUNTED.
"C"DENOTES CEILING MOUNTED. "R" DENOTES
RECESSED MOUNTED.
RECESSED CAN LIGHT. REFER TO LIGHT FIXTURE
SCHEDULE.
SURFACE, STEM OR CHAIN MOUNTED LIGHT
FIXTURE. "EM" DENOTES EMERGENCY FIXTURE.
REFER TO LIGHT FIXTURE SCHEDULE.
RECESSED OR CHAIN HUNG LIGHT FIXTURE (2' X
4"). REFER TO LIGHT FIXTURE SCHEDULE FOR TYPE
AND PERFORMANCE..
RECESSED LIGHT FIXTURE SERVED FROM
EMERGENCY BRANCH REFER TO LIGHT FIXTURE
SCHEDULE FOR TYPE AND PERFORMANCE..
EXIT FIXTURE. ARROW DENOTES DIRECTION OF
KNOCK-OUT ARROWS. REFER TO LIGHT FIXTURE
SCHEDULE.
COMBINATION EXIT AND EMERGENCY LIGHT
FIXTURE, WALL MOUNTED. REFER TO LIGHT
FIXTURE SCHEDULE.
OCCUPANCY SENSOR. REFER TO SPECIFICATIONS
AND LIGHT FIXTURE SCHEDULE.
20 AMP - SINGLE POLE TOGGLE SWITCH -
COMMERCIAL GRADE. FLUSH MOUNT UP 48" AFF
OR AS NOTED. "K" DENOTES KEY TYPE SPEC
GRADE.
ELECTRICAL SYMBOLS
POWER AND PANELS
SYMBOL DESCRIPTION
PANELBOARD
TRANSFORMER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
T
L-002
EL
EC
TR
IC
AL
KE
YN
O
TE
S
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
ELECTRICAL KEYNOTES NOTES
1 REMOVE AND DISPOSE OF EXISTING LIGHT FIXTURE. REMOVE CORD AND PLUG OR REMOVE
CONDUIT AND WIRE BACK TO JUNCTION BOX. REMOVE RECEPTACLE AND PROVIDE JUNCTION
BOX COVER. REUSE CIRCUIT TO FEED NEW LIGHT FIXTURE(S).
REMOVE AND DISPOSE OF EXISTING LIGHT FIXTURE. REMOVE CORD AND PLUG OR REMOVE
CONDUIT AND WIRE BACK TO JUNCTION BOX. REMOVE RECEPTACLE AND PROVIDE J-BOX
COVERPLATE.
REPLACE EXISTING LIGHT FIXTURES WITH NEW FIXTURE. MOUNT THE NEW FIXTURE TO
MATCH THE EXISTING MOUNTING HEIGHT.
REPLACE EXISTING EXIT SIGN WITH NEW FIXTURE F12. CONNECT TO EXISTING CIRCUIT.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 20 FT AFF. CONNECT TO EXISTING NORMAL POWER. PROVIDE 6 FT WHIP.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 18 FT AFF. CONNECT TO EXISTING NORMAL POWER. PROVIDE 6 FT WHIP.
2#8, 1#8 GND IN ¾” CONDUIT TO EMERGENCY LIGHTING PANEL.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATLEY 20 FT AFF. CONNECT TO EXISTING NORMAL POWER AND EMERGENCY
LIGHTING PANEL ELP-2-299. PROVIDE SEPARTE 6 FT WHIPS.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 38 FT AFF. CONNECT TO EXISTING NORMAL POWER. PROVIDE 6 FT WHIP.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 38 FT AFF. CONNECT TO EXISTING NORMAL POWER AND EMERGENCY
LIGHTING PANEL ELP-2-299. PROVIDE SEPARATE 6 FT WHIPS.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 18 FT AFF. CONNECT TO EXISTING NORMAL POWER AND EMERGENCY
LIGHTING PANEL ELP-3-299. PROVIDE SEPARATE 6 FT WHIPS.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 20 FT AFF. CONNECT TO EXISTING NORMAL POWER AND EMERGENCY
LIGHTING PANEL ELP-3-299. PROVIDE SEPARATE 6 FT WHIPS.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 38 FT AFF. CONNECT TO EXISTING NORMAL POWER AND EMERGENCY
LIGHTING PANEL ELP-3-299. PROVIDE SEPARATE 6 FT WHIPS.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING ADJACENT LIGHT
FIXTURES, APPROXIMATELY 18 FT AFF. REVISE CONDUIT AND WIRING TO CONNECT TO
EXISTING LIGHTING PANEL.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING ADJACENT LIGHT
FIXTURES, APPROXIMATELY 18 FT AFF. REVISE CONDUIT AND WIRING TO CONNECT TO
EXISTING LIGHTING PANEL. ALSO PROVIDE CONDUIT AND WIRE TO CONNECT TO EMERGENCY
LIGHTING PANEL ELP-4-299.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 18 FT AFF. CONNECT TO EXISTING NORMAL POWER AND EMERGENCY
LIGHTING PANEL ELP-4-299. PROVIDE SEPARATE 6 FT WHIPS.
REMOVE ABANDONED STEAM UNIT HEATER AT THIS LOCATION TO ALLOW FOR INSTALLATION
OF THE NEW LIGHT ON THE COLUMN CENTERLINE AS SHOWN.
PROPOSED LOCATION FOR NEW EMERGENCY LIGHTING UPS SYSTEM. PROVIDE LIGHTING,
RECEPTACLES, ELECTRIC UNIT HEATER AND MINI-SPLIT AC SYSTEM. ADJACENT AREAS TO
THE EAST, SOUTH AND WEST ARE UNHEATED AND UN-AIR CONDITIONED. THE ADJACENT
AREA TO THE NORTH IS HEATED BUT NOT AIR CONDITIONED.
ELECTRICAL SUBSTATION FOR 480V POWER FOR THE NEW EMERGENCY LIGHTING UPS
SYSTEM.
EXISTING LIGHTING PANEL IS INTEGRATED INTO THE EXISTING LIGHTING CONTROL SYSTEM.
REMOVE CONTROLS FROM THE EXISTING PANEL OR REPLACE THE LIGHTING PANEL.
REMOVE EXISTING DAYLIGHT SENSOR AND ALL CONTROL WIRING.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 55 FT AFF. CONNECT TO EXISTING NORMAL POWER. PROVIDE 6 FT WHIP.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 20 FT AFF. CONNECT TO EXISTING NORMAL POWER AND EMERGENCY
LIGHTING PANEL ELP-5-299. PROVIDE SEPARATE 6 FT WHIPS.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 55 FT AFF. CONNECT TO EXISTING NORMAL POWER AND EMERGENCY
LIGHTING PANEL ELP-5-299. PROVIDE SEPARATE 6 FT WHIPS.
INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT FIXTURE,
APPROXIMATELY 10 FT AFF. CONNECT TO EXISTING NORMAL POWER. PROVIDE 6 FT WHIP.
THERE IS ONE FIXTURE MOUNTED AT APPROXIMATELY 20 FT AFF AND A SECOND FIXTURE
MOUNTED AT APPROXIMATELY 24 FT AFF. BOTH FIXTURES ARE TO BE REMOVED.
ELECTRICAL KEYNOTES NOTES
REMOVE AND DISPOSE OF EXISTING LIGHT FIXTURE. REMOVE CORD AND PLUG OR REMOVE
CONDUIT AND WIRE BACK TO JUNCTION BOX. EMERGENCY POWER FOR THIS FIXTURES
COMES FROM THE EXISTING UPS SYSTEM LOCATED IN THE MECHANICAL/ELECTRICAL ROOM
ON THE SECOND FLOOR OF THE OFFICE COMPLEX. REMOVE ALL WIRING AND CONDUIT BACK
TO THE SOURCE. THE NEW EMERGENCY LIGHTING WILL NOT BE RECONNECTED TO THIS UPS
SYSTEM. REFER TO DRAWING LD-401. CONNECT NEW FIXTURE AT THIS LOCATION TO THE
NEAREST NORMAL POWER LIGHTING CIRCUIT.
REMOVE AND DISPOSE OF EXISTING LIGHT FIXTURE. REMOVE CORD AND PLUG OR REMOVE
CONDUIT AND WIRE BACK TO JUNCTION BOX. EMERGENCY POWER FOR THIS FIXTURES
COMES FROM THE EXISTING UPS SYSTEM LOCATED IN THE MECHANICAL/ELECTRICAL ROOM
ON THE SECOND FLOOR OF THE OFFICE COMPLEX. REMOVE ALL WIRING AND CONDUIT BACK
TO THE SOURCE. THE NEW EMERGENCY LIGHTING WILL NOT BE RECONNECTED TO THIS UPS
SYSTEM. REFER TO DRAWING LD-401.
EXTEND NORMAL POWER TO THIS LOCATION FROM THE CLOSEST NORMAL POWER LIGHTING
CIRCUIT. INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT
FIXTURE, APPROXIMATLEY 20 FT AFF. CONNECT TO EXISTING NORMAL POWER AND
EMERGENCY LIGHTING PANEL ELP-2-299. PROVIDE SEPARTE 6 FT WHIPS.
EXTEND NORMAL POWER TO THIS LOCATION FROM THE CLOSEST NORMAL POWER LIGHTING
CIRCUIT. INSTALL NEW LIGHT FIXTURE TO MATCH THE ELEVATION OF THE EXISTING LIGHT
FIXTURE, APPROXIMATLEY 20 FT AFF. CONNECT TO EXISTING NORMAL POWER AND PROVIDE
SEPARTE 6 FT WHIPS.
REMOVE AND REPLACE EXISTING LIGHT FIXTURE. NEW FIXTURES SHALL HAVE DIMMING AND
DAYLIGHTING CAPABILITY WHERE REQUIRED. NEW LIGHT FIXTURES SHALL BE TYPE F18.
REFER TO THE LIGHTING CONTROL SEQUENCES. RECONNECT TO EXISTING LIGHTING
CIRCUIT. PROVIDE LIGHTING CALCULATIONS IN ACCORDANCE WITH THE STATEMENT OF
WORK (SOW).
REMOVE EXISTING LIGHTING CONTROL OCCUPANCY SENSORS AND ALL CONTROL WIRING.
REMOVE EXISTING LIGHT SWITCHES AND PROVIDE NEW LIGHT SWITCHES WITH ON-OFF
CONTROL AND DIMMING CAPABILITY IN 3-WAY CONFIGURATION.
REMOVE EXISTING LIGHT SWITCHES AND PROVIDE NEW LIGHT SWITCHES WITH ON-OFF
CONTROL AND DIMMING CAPABILITY.
REMOVE EXISTING LIGHT SWITCHES AND PROVIDE NEW LIGHT SWITCHES WITH ON-OFF
CONTROL ONLY.
REMOVE AND REPLACE EXISTING LIGHT FIXTURE. RECONNECT TO EXISTING LIGHTING
CIRCUIT. PROVIDE LIGHTING CALCULATIONS IN ACCORDANCE WITH THE STATEMENT OF
WORK (SOW).
REMOVE EXISTING LIGHT SWITCHES AND PROVIDE NEW LIGHT SWITCHES WITH ON-OFF
CONTROL ONLY IN 3-WAY CONFIGURATION.
REMOVE EXISTING LIGHT SWITCHES AND PROVIDE NEW LIGHT SWITCHES WITH ON-OFF
CONTROL AND DIMMING CAPABILITY. ONE SWITCH SHALL CONTROL THE MAIN LIGHTING. ONE
SWITCH SHALL CONTROL THE CAN LIGHTS ALONG THE EAST WALL. ONE SWITCH SHALL
CONTROL THE CAN LIGHTS ALONG THE NORTH WALL.
REMOVE EXISTING LIGHT SWITCHES AND PROVIDE NEW LIGHT SWITCHES WITH ON-OFF
CONTROL ONLY. THIS SWITCH SHALL CONTROL THE LIGHT FIXTURES MOUNTED IN THE
SHOWER STALLS. PROVIDE ONE SWITCH FOR EACH SHOWER STALL.
REMOVE EXISTING EXIT SIGN AND INSTALL NEW COMBINATION EXIT SIGN / EMERGENCY
LIGHT FIXTURE F12. RECONNECT TO EXISTING CIRCUIT.
REMOVE AND REPLACE EXISTING LIGHT FIXTURE. NEW FIXTURES SHALL HAVE DIMMING AND
DAYLIGHTING CAPABILITY WHERE REQUIRED. REFER TO THE LIGHTING CONTROL
SEQUENCES. RECONNECT TO EXISTING LIGHTING CIRCUIT. EXISTING LIGHTS ARE MOUNTED
AT VARIOUS HEIGHTS FROM 10 FT TO 18FT. THE NEW LIGHT FIXTURES SHALL BE INSTALLED
AT A NEW ELEVATION OF APPROXIMATLEY 12 FT AFF. EMERGENCY LIGHTING LEVELS SHALL
ALSO BE EVALUATED. IF ADDITIONAL LIGHTING IS REQUIRED, PROVIDE FIXTURES SIMILAR TO
THE OPEN WAREHOUSE AREAS AND CONNECT THE EMERGENCY POWER TO PANEL
ELP-2-299. PROVIDE LIGHTING CALCULATIONS IN ACCORDANCE WITH THE STATEMENT OF
WORK (SOW).
REMOVE AND REPLACE EXISTING LIGHT FIXTURE. NEW FIXTURES SHALL HAVE DIMMING AND
DAYLIGHTING CAPABILITY WHERE REQUIRED. REFER TO THE LIGHTING CONTROL
SEQUENCES. RECONNECT TO EXISTING LIGHTING CIRCUIT. EMERGENCY LIGHTING LEVELS
SHALL ALSO BE EVALUATED. IF ADDITIONAL LIGHTING IS REQUIRED, PROVIDE FIXTURES
SIMILAR TO THE OPEN WAREHOUSE AREAS AND CONNECT THE EMERGENCY POWER TO
PANEL ELP-2-299. PROVIDE LIGHTING CALCULATIONS IN ACCORDANCE WITH THE STATEMENT
OF WORK (SOW).
FURNISH AND INSTALL NEW COMBINATION EXIT SIGN / EMERGENCY LIGHT FIXTURE F12.
CONNECT TO CLOSEST UNSWITCHED EXISTING CIRCUIT.
THE LIGHTS MOUNTED IN THE CANOPY SHALL BE CONTROLLED STRICTLY BY THE
OCCUPIED/UNOCCUPIED SCHEDULE.
REMOVE EXISTING LIGHTING CONTROL OCCUPANCY SENSORS AND ALL CONTROL WIRING.
PROVIDE NEW LIGHT SWITCHES WITH ON-OFF CONTROL AND DIMMING CAPABILITY.
ELECTRICAL KEYNOTES NOTES
REMOVE EXISTING LIGHTING CONTROL OCCUPANCY SENSORS AND ALL CONTROL WIRING.
PROVIDE NEW LIGHT SWITCHES WITH ON-OFF CONTROL AND DIMMING CAPABILITY IN 3-WAY
CONFIGURATION.
REMOVE EXISTING LIGHTING CONTROL OCCUPANCY SENSORS AND ALL CONTROL WIRING.
PROVIDE NEW LIGHT SWITCHES WITH ON-OFF CONTROL.
REMOVE EXISTING LIGHT SWTICH AND PROVIDE NEW SWITCH WITH ON-OFF CONTROL. LIGHT
FIXTURES IN THIS ROOM SHALL NOT INCORPORATE OCCUPANCY SENSORS OR DAYLIGHT
CONTROL.
REPLACE THE LAY-IN CEILING GRID SYSTEM AND LAY-IN TILES.
PROVIDE ON-OFF LIGHT SWITCH TO OVERRIDE THE LIGHTING CONTROL SCHEDULE DURING
OFF HOURS. REFER TO THE LIGHTING CONTROL SEQUENCES.
PROPOSED LOCATION FOR NEW EMERGENCY LIGHTING UPS SYSTEM. PROVIDE LIGHTING,
RECEPTACLES, ELECTRIC UNIT HEATER AND MINI-SPLIT AC SYSTEM. ADJACENT AREAS ARE
HEATED BUT NOT AIR CONDITIONED. POWER FOR THE NEW EMERGENCY LIGHTING UPS
SYSTEM SHALL COME FROM THE BUS DUCT LOCATED AT APPROXIMATELY COLUMN LINES 12
AND C.
#4 IN 1” CONDUIT TO EMERGENCY LIGHTING PANEL.
#3 IN 1-1/4" CONDUIT TO EMERGENCY LIGHTING PANEL.
LD-101
LI
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 1 2 3 4 5 6 7 8
A
B
C
D
E
C O
N
TI
N U
ED
S
H
EE
T
LD
-1
CONTINUED SHEET LD-108
F18F18
F18F18F18F18
F18F18F18
F18F18F18F18
F1
F18
LIGHTING CONTROL
SWITCH
F3 9 F18F18
F4
1 1 27
27 1
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1/8"=1'0"
LD-102
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
E
C O
N
TI
N U
ED
S
H
EE
T
LD
-1
CONTINUED SHEET LD-109
C O
N
TIN
U
ED
SH
EET LD
-101
F3
F3
F3
F4
F4
F4
F4
F4
F18 F18
F18
F18
F68
F18
F18F18F18
F18
F18
F18 F18F18F18 F1
F18 F18 F18 F18F18
F18
F18 F18 F18F18
F18 F18 F18 F18F18
F18 F18 F18F18
F18 F18
F18
F18
F18
DEMO LIGHTING CONTROL
SWITCH AND WIRING
F4
2711111
1 1 1 1 1
271111
27 1 1 1 1 1
271111
2 2
1 1 1
1 1
1 1
1 26 28
1 26 28
28 28
F4
F18 F18
F18 F18 F18
F18 F18
F18
F18
F1
F1
F18
POWDER
41 41
41 41
41 41
F1
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LD-103
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 9 20 21 22 23 24 25 26 27 28 29 3
A
B
C
D
E
C O
N
TI
N U
ED
S
H
EE
T
LD
-1
CONTINUED SHEET LD-110
C O
N
TIN
U
ED
SH
EET LD
-102
F23F22F23F23
F23
F23F22F23F23F23F23
F23F22F23F22F23
F23F22F23F22
F23
F23F23F23F23F23F23
F23
F23F22F23F22
F23F22F23F23F23
F3 9F18
F18
F18
F18
F18
F1
F1
F18
F18
F18
DEMO LIGHTING CONTROL
SWITCH AND WIRING
F1
F3
F2
F78
F23 F23 F23 F23 F23 F23 F23
1 1
1 2
1 1
1 1 2
1 1
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LD-104
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 30 31 32 33 34 35 36 37 38 39 40
A
B
C
D
E
F15F23
F23
F23
F23
F23
F23
F23
F22
F22
F22
F22
F23
F22
F22
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F22
F22
F22
F22
F23
F22
F22
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F23
F15
F15
F15
F15
F23 F23 F23 F23 F23 F23 F23
1 1
1 1
1 2
2 1 1
1 2
1 1
2 1 1 12 21 1
C O
N
TI
N U
ED
S
H
EE
T
LD
-1
CONTINUED SHEET LD-111
C O
N
TIN
U
ED
SH
EET LD
-103
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LD-105
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 41 42 43 44 45 46 47 48 49 50 51
A
B
C
D
E
F15 F16
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
F2
LP-??-299
F15 F15 F15 F15 F16 F16 F16 F16 F16
F15 F16F15 F15 F15 F15 F16 F16 F16 F16 F16
F15 F16F15 F15 F15 F15 F16 F16 F16 F16 F16
F15 F16F15 F15 F15 F15 F16 F16 F16 F16 F16
F15
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F2
F2
F2
F2
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
F1
1 1
2 1
1 1
2 1
1 1
2 1
1 1
2 1
1 1
2 1
2 1
1 2
2 2
2 1
1 2
2 1 2
2 2 1 2 2 1 2 2 1 2 2 1 2 2 1 2
C O
N
TI
N U
ED
S
H
EE
T
LD
-1
CONTINUED SHEET LD-112
C O
N
TIN
U
ED
SH
EET LD
-104
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LD-106
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 52 53 54 55 56 57 58 59 60 61 62
A
B
C
D
E
F2 F2
F2 F2
F2
F1
F1
F4
F14 F14F14 F14
F1
F1
F1
F1
F1
F1
F15
F15
F15
F15
F16 F16 F16
F16
F1
F1
F1
F1
F2
F2
F2
F2
F16
F16
F1
F1
F1
F1
F1
F16
F16 F16
F16
F16
F16
F16
F15
F15
F16
F16
F16
F16
F16
F16
F16
F16
F16
F16
F16
F16
F16
F16
F16
2 1
1 1
2 2
2 1 1
1 1
1 1
2 2
2 2
C O
N
TI
N U
ED
S
H
EE
T
LD
-1
CONTINUED SHEET LD-113
C O
N
TIN
U
ED
SH
EET LD
-105
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LD-107
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 62 63 64 65 66 67 68 69 70 71 72
A
B
C
D
E
F1 F1
F4 F4 F4 F4
F4
F4 F4
F4
F1 F1
F1 F1
F1
F1 5 F78
F1 F1
F1 F1
F1 F1
F? F?
F? F? F?
F?F?F?
F? F?
F?
F?
1 2 1
2 2
1 1
1 1
1 1
1 1
1 1 1
CONTINUED SHEET LD-114
C O
N
TIN
U
ED
SH
EET LD
-106
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1/8"=1'0"
AutoCAD SHX Text F?
F?
LD-108
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 1 2 3 4 5 6 7 8
F
G
H
K
L
M
C O
N
TI
N U
ED
S
H
EE
T
LD
-1
CONTINUED SHEET LD-115
CONTINUED ON LD-101
F39
F3
F3
F18F18F18F18F18F18
F1
F18F18F18F18
F18
F18F18F18F18F18F18F18F18
F18F18F18F18
F18F18
F18
F18F18
F18
F18
F3
DEMO LIGHTING CONTROL
SWITCH AND WIRING
F3
F3
F3
F3
F18 F3
F39
F39
F39
F39
F39
DEMO LIGHTING CONTROL
SWITCH AND WIRING
F18
F18
F18
F1
F1
1 1 1
1 1 1 1 1 1 1
27127127127
1 1 1 1
271272727
27 27 1
2822828
1 28
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LD-109
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 9 10 11 12 13 14 15 16 17 18 19
F
G
H
K
L
MF3
F3
F3
F3
F3
F3
F3
F18 F18
F1
F3
F18 F18F18F18 F18
F18F18 F18
F18
F18F18 F1 8 F18
F18F18 F18
F3
F3
F18 F18 F18 F18F18
F18 F18 F18
F18 F18
F18 F18 F18 F18F18
F18 F18F18
F18
F18
F18F18F18F18F18F18F18F18F18
F18 F18
F18
F18 F18
F18 F18
F1
F1
F1
F1
F1
F1
F1
F1
F3 9 F18F3
F3
F1
F1
F1
F3
F1 8F18
F3
1 1 1 1 1
271111
1 1 1 1 1
2711271
1 1 1 1 1
12727
111111
1 1 1
1 1
1 1
28 28 28 28
26 28
F18
F18
F18
F4
F1
C O
N
TI
N U
ED
S
H
EE
T
LD
-1
CONTINUED SHEET LD-116
CONTINUED ON LD-102
C O
N
TIN
U
ED
SH
EET LD
-108
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LD-110
G
H
TI
N G
D
EM
O
LI
TI
O
N
AR
EA
D
AT
E
AP
PR
M
AR
K D
ES
C
R
IP
TI
O
N
SU
BM
IT
TE
D B
Y:
IS
SU
E D
AT
E:
PR
O
JE
C
T N
O
D R
AW
IN
G N
O
U .S
. A R
M Y
G
AR
R
IS
O N
R
O C
K
IS
LA
N
D A
R
SE
N
AL
D
IR
EC
TO
R
AT
E O
F
PU
BL
IC
W O
R
KS
R O
C K
IS
LA
N D
, I L
9-
-1
9-
/1
6/
D
ES
IG
N
ED
B Y:
G . S
C H
AU
B, II
I
D R
AW
N
B Y:
G . S
C H
AU
B, II
I
C H
EC
KE
D B
Y:
S.
BA
C
H
AP
PR
O
VE
D B
Y:
G
. K O
SK
I, D
IR
EC
TO
R O
F
PU
BL
IC
W O
R
KS
S.
B
AC
H
, C H
IE
F
O F
EN
G
IN
EE
R
C K
IS
LA
N D
A R
SE
N
AL
R
EP
AI
R B
Y R
EP
LA
C
EM
EN
T
N O
R M
AL
A
N D
E M
ER
G
EN
C
Y
LI
G H
TI
N
G
BU
IL
D
IN
G
PR
O
JE
C T
-1
2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G 9 20 21 22 23 24 25 26 27 28 29 3
F
G
H
K
L
M
LP-6-299
F18
F18
F18
F18
F18
F18
F18
F79 F79
F79 F79
F79 F79
F79 F?
F23 F23 F23 F23 F23
F23 F23 F23 F23 F23 F23
F23 F23 F23 F23 F23
F23 F23 F23 F23 F23 F23
F23 F23 F23 F23 F23
F23 F23 F23 F23 F23 F23
F23 F23 F23 F23 F23
F23 F23 F23 F23 F23 F23
F23 F23 F23 F23 F23
1 1 2 2 1
2 1
1 1
1 1
1 1
C O
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .