Attach B Electro-Guard 5000 Spare Parts.xlsx
XLSX spreadsheet 14 KB Posted
- Attached to
- Maintenance for 16 Lethal/Non-Lethal Fences Federal contract opportunity
- Solicitation number
- 15BNAS24R00000005
About this file
This document contains an attachment listing spare parts and components for lethal and non-lethal electrified fence systems, as well as details for a related federal contract opportunity to provide maintenance services for 16 such fence systems. The attachment includes a table listing various spare parts such as complete cabinet assemblies, controllers, software, fiber modules, and physical fence structure components. The federal contract opportunity is solicited by the Department of Justice Bureau of Prisons Central Office to maintain the 16 lethal/non-lethal fences, with any questions due by January 30, 2024 at noon EST as stated in the statement of work.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 15BNAS24R00000005-0002.pdf | ||
| 15BNAS24R00000005-0002.pdf | ||
| Less Lethal-lethal fence questions Second Round 1.docx | DOCX document | |
| Attach B Electro-Guard 5000 Spare Parts.xlsx | XLSX spreadsheet | |
| Attach A Emergency Parts.xlsx | XLSX spreadsheet | |
| 15BNAS24R00000005-0001.pdf | ||
| Responses to Questions.docx | DOCX document | |
| 15BNAS24R00000005 Amendment 1.zip | ZIP file | |
| 8 STATEMENT OF WORK NonLethal-Lethal Maintenance.docx | DOCX document | |
| Instructions_and_Evaluation.pdf | ||
| 8 STATEMENT OF WORK NonLethal-Lethal Maintenance.docx | DOCX document | |
| Past Performance Questionnaires.doc | DOC document | |
| Attach A Emergency Parts.xlsx | XLSX spreadsheet |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Table 1 Electro-Guard 5000 Spare Parts
| Part Name | Description |
| Energizer Cabinet - Complete Assembly | Cabinet consists of a Lethal and Non-Lethal Energizer capable of operating an entire perimeter fence. The energizer has the capability of switching between lethal and non-lethal modes along with dividing the perimeter into separate zones |
| Isolation Switch - Complete Assembly | Isolation Switch is utilized to ground the entire perimeter fence. When grounded, any stray voltage on the fence will dissipate |
| Rodent Energizer - Complete Assembly | Rodent Energzier is utilized to deter animals from climbing onto the Electric Fence and potentially causing nusaince alarms and hurting the animal |
| Sallyport Controller - Complete Assembly | The Controller consists of a touchscreen and all associated equipment to monitor and control the Lethal/Non-Lethal perimeter fence system |
| Cabinet with Custom Turret for Monitor | The cabinet where the monitor and equipment is installed |
| Allen Bradley Software | Software that is required to run the custom monitoring and controlling software |
| GUI Map | Graphic representation of the Lethal/Non-Lethal perimeter fence system |
| ElectroGuard 5000 Custom Software | Custom software with the capability of monitoring and controlling the Lethal/Non-Lethal perimeter fence system |
| Power Supply | Powers the cabinet |
| PLC | PLC controls the inputs and outputs and relays the information to the controller |
| PLC Input Module x 2 | The input module brings notifications to the PLC |
| PLC Output Module | The output module sends notifications to equipment |
| PLC Power Supply | Powers the PLC, input and output modules |
| PLC End Cap | Connects the entire PLC |
| TTL D/O Module | Allows the switching between fiber connections |
| Programming Cable | Cable utilized to upload software to the PLC |
| Plug-in Relay | Drives the siren |
| Allen Bradley Touchscreen Computer | Computer is the graphic interface that monitors and controls the Lethal/Non-Lethal Electrified Fence System |
| Siren | Alerts users when there is an alarm |
| Housekeeping Pad | Pad keeps equipment off the ground and allows for cabling below the cabinet |
| Admin Controller - Complete Assembly | The Controller consists of a touchscreen and all associated equipment to monitor and control the Lethal/Non-Lethal perimeter fence system |
| Cabinet with Turret and Monitor cutout | The cabinet that the Controller is installed in |
| Allen Bradley Touchscreen | Computer is the graphic interface that monitors and controls the Lethal/Non-Lethal Electrified Fence System |
| GUI Map | Graphic representation of the Lethal/Non-Lethal perimeter fence system |
| Siren | Alerts users when there is an alarm |
| Admin Equipment Room Rack - Complete Assembl | The cabinet consists of a database computer to review the history of the fence system along with networking equipment and the Remote Annunciation Notification |
| Equipment Room Cabinet | The cabinet where all of the equipment is installed |
| Cisco Network Switch | Network switch that allows all of the controllers to communicate |
| Black Box Fiber Module | The fiber module is where the fiber is connected at each end |
| RANS PLC Output Module x 4 | The output modules allow for each zone of the perimeter to be announced over the RANS System |
| RANS PLC Power Supply | The power supply provides power to the complete RANS PLC system |
| RANS PLC Ethernet Adapter | Connects the RANS module to the PLC |
| Power Supply - IDEC | The power supply provides power to the entire Equipment Room Cabinet |
| Database PC | Standard computer with software to review the Perimeter Fence history |
| Printer | Printer is utilized to make hard copies of the Perimeter Fence history |
| Fence Structure Components | The physical structure that creates a secure facility |
| 12' Strain Post with Mounting Tabs | A strain post, also known as the end of the zone, is utilized to create tension on all wires within a zone. |
| 12' Corner Post with Mounting Tabs | A corner post acts similar to a strain post but is not an inline post. Corner posts typically connect two different zones at an angle |
| Part Name | Description |
| 12' Inline Post with Mounting Tabs | Inline posts hold electrified wire and ensure the wire stay taught |
| Insulator | Insulators are used to hold the electrified wire away from the post |
| Insulator Pins (including nuts) | Pins are used to hold the insulators to the fence posts |
| Insulator Springs | Springs are used to hold the electrified wire to the |
| Electrified Wire | Electrified Wire is strung taught around the entire perimeter and is energized to deter an escape |
| Electrified Tensioner | Tensioners are used to create tension within a zone |
| Stainless Steel Crimps | Crimps are used to splice stainless steel wire to itself |
| Rodent Insulator | Insulators are used to hold the rodent wire |
| Rodent Pin (including nut & washer) | Pins are used to attached a rodent insulator to a post |
| Rodent Tensioner | Tensioners are used to create tension within a zone |
| Field Lightning Arrestors | Lighting Arrestors are used to prevent power surges that could potentially damage equipment |
| Copper Jumper Wire (unbent) | Jumper wire is utilized to move a phase of electricity from one stainless steel wire to another |
| Copper Crimp | Crimps are used to connect jumper wire to the electrified wire |
| HT Cable (Energizer to Fence) | Cable is used to run power from the Energizer cabinet to the electrified fence line |
| Traffic Light | Traffic Light is an indicator for personnal to understand the status of the Lethal/Non-Lethal Fence system |
| Warning Signs | Signs are used to warn individuals on the inside and outside of the facility that there is a dangerous Electrified Fence System around the perimeter of the prison |
| Stereo Doppler Microwave - Sensor Only | Microwaves are used to pick up motion within the Sallyport |
| Ground Cable - Main (Price vary daily) | Ground Cable buried around the entire perimeter to create one large grounding grid |
| Ground Cable - Whip (Price vary daily) | Ground cable used to connect the main ground to each individual post |
| CAD Weld to post | Welds are used to connect ground whips to posts |
| CAD Weld Main Cable | Welds are used to splice the main ground cable |
| CAD Weld Whips to Post | Welds are used to connect ground whips to the main ground cable |
| Specialty Retrofit Components - GDI System | |
| 12' Angle with Mounting Holes - Post Modificatio | Angle is used to attach to an existing post to retrofit a GDI Electrified Fence System to a Detekion Security Electrified Fence System |
| Slide Lock Set - Sallyport Gates | Locks are utilized at the Sallyport Gates to secure the perimeter system and prevent any unauthorized access |
Attachment B
&P