Att12_230170_Drawings.pdf
PDF 1 MB Posted
- Solicitation number
- FA813726R0031
About this file
Summary
This is a set of construction design documents for the installation of a Mass Notification System (MNS) and replacement of heat detectors in Building 976 at Tinker Air Force Base, Oklahoma. The project, designated WWYK230170, is a Design-Build contract issued by the Air Force Materiel Command's 72nd Air Base Wing Civil Engineer Directorate with an issue date of April 1, 2026.
The project scope includes demolishing existing alarm notification devices and heat detectors, demolishing circuits back to the control panel without abandonment in place, and providing a new fire alarm and mass notification system throughout the facility. Key requirements include 100% acceptance testing, approved penetrations through fire-rated construction per Tinker Air Force Base Fire Protection Standards, and compliance with multiple code references including UFC 1-200-01 (DOD Building Code), UFC 3-600-01 (Fire Protection Engineering), UFC 4-021-01 (Mass Notification Systems), NFPA 70 (National Electric Code), NFPA 72 (National Fire Alarm and Signaling Code), and NFPA 400 (Hazardous Materials Code). The contractor is responsible for field verification of existing conditions, site protection with fencing and barricades, and repair or replacement of any damaged grounds or facilities to match or exceed existing conditions at no additional cost to the government. The facility contains Class 1 Division 1 electrically classified areas within the hangar bay, requiring specialized design considerations for all electrical and alarm system components.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REVIEWED BY:
REVIEWED BY:
USING AGENCY:
ASBESTOS EVALUATION:
SAFETY:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
INDUSTRIAL HYGIENE:
DATE:
PROJECT DRAWING INDEX SIGNATURES
CORROSION ENGINEER: (CECE)
CE OPERATIONS: (CECO)
COMMUNICATIONS: (COMM)
CHIEF ENGINEER DIR: (CECE)
CHIEF DESIGN BRANCH: (CECE)
DESIGN MANAGER: (CECE)
ZONE MANAGER:
CONSTRUCTION MANAGEMENT: (CECE)
ENVIRONMENTAL:
BASE CIVIL ENGINEER: (CE)
FIRE DEPARTMENT
GENERAL1. BRAND NAMES: REFERENCE TO SPECIFIC BRAND NAMES
OR COMPANIES IS FOR THE PURPOSE OF ESTABLISHING
MINIMUM QUALITY STANDARDS, IDENTIFICATION AND
GUIDANCE AND IS NOT INTENDED TO LIMIT SELECTION OF
OTHER MANUFACTURERS THAT ARE EQUAL OR EXCEED
THE SPECIFIED ITEMS IN TERMS OF PHYSICAL
PROPERTIES, INCLUDING, COLOR RANGE, FINISH,
DURABILITY, APPEARANCE, PERFORMANCE
CHARACTERISTICS, AND OTHER FACTORS. OTHER
PRODUCTS, MATERIALS, COLORS AND SYSTEMS, MAY BE
SUBMITTED FOR EVALUATION AND
APPROVAL/DISAPPROVAL BY THE CONTRACTING OFFICER.
2. THIS SET OF CONSTRUCTION DOCUMENTS SHALL BE
CONSIDERED AS A WHOLE IN THAT THE GENERAL
CONTRACTOR AND ALL THE SUB-CONTRACTORS ARE
RESPONSIBLE FOR THE INFORMATION PRESENTED ON ALL
SHEETS ON THE SET OF DRAWINGS AND ALL SECTIONS OF
THE SPECIFICATIONS.
3. THE CONTRACTOR IS RESPONSIBLE FOR ERECTING ALL
CONSTRUCTION FENCING AND BARRICADES AS REQUIRED
TO PROTECT CONSTRUCTION MATERIAL AND TO PREVENT
ANY UNAUTHORIZED PERSONNEL FROM ENTERING THE
CONSTRUCTION SITE.
4. ANY DAMAGE TO THE EXISTING GROUNDS OR FACILITIES
CAUSED BY CONSTRUCTION TRAFFIC OR ANY
CONSTRUCTION OPERATION SHALL BE REPAIRED OR
REPLACED BY THE CONTRACTOR TO MATCH OR EXCEED
EXISTING CONDITIONS AT NO ADDITIONAL COST TO THE
GOVERNMENT.
5. ALL WORK NOTED & LOCATED IN THESE DOCS SHALL BE
UNDERSTOOD BY THE CONTRACTOR TO REQUIRE ALL NEW
LABOR & MATERIALS UNLESS SPECIFICALLY NOTED TO BE
"EXISTING" OR "BY OTHERS".
WWYK230170
INSTALL MNS & REPLACE
HEAT DETECTORS, B976
KEY PLAN:
GENERAL NOTES:
DISCIPLINE
PROJECT
LOCATION
1 G-101 GENERAL NOTES & VICINITY MAP
SHT.SEQ. SHEET TITLE
OF
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
DESIGN
BUILD
W W
YK
IN
ST
AL
L M
NS
R
EP
LA
CE
HE
AT
D
ET
EC
TO
RS
, B
1A
PR
IL
TE
PA
-S R
M
A M
C
PE
R
SO
N
G-101
N B
IR
C
H U
M
En gr
\D es ig n\ s\
\2
0\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
GE
NE
RA
L N
OT
ES
AN
D
VI
CI
NI
TY
M
AP
01 03
FD101 FIRE ALARM DEMOLITION PLAN
3 FA101 FIRE ALARM / MASS NOTIFICATION PLAN
R U
N W
AY
8/
RUNWAY 13/31
TA
XI
W
AY
G
TAXIW
AY H
TAXIWAY B
TAXIWAY C
TAXIWAY M
TA
XI
W
AY
K
TAXIWAY E
TAXIWAY A
TA
XIW
AY E
E
TAXIWAY F
TAXIWAY D
TAXIWAY E
TAXIWAY J
TA
XI
W
AY
G
TAXIWAY A
TAXIW
AY H
TAXIWAY C
TAXIWAY D
TAXIWAY EE
TAXIWAY F
Elm C reek
Crutcho Creek
Kuhlman Creek
Soldier Creek
Kuhlman Creek
Elm C reek
East Crutcho Creek
Elm Creek
El m
C re ek
Elm Creek
Elm C reek
Elm CreekElm C reek
Ku hlm an C re ek
Ea st
C ru tc ho
C re ek
Elm C ree k
West Crutcho Creek
W es t C ru tc ho
C re ek
Elm Creek
Soldier Creek
Elm C reek
Soldier CreekSoldier Creek
Ea st
C ru tc ho
C re ek
Elm Creek
Ea st
C ru tc ho
C re ek
East C rutcho C reek
Soldier Creek
So ld ie r C re ek
East C rutch o Creek
Soldier C reek
Soldier C reek
So ld ie r C re ek
East Crutcho Creek
416506
21222121
59475946
11401128
62540
61089
838837
62509
62528
62523
62501X
43774
62512
62516
62525
3592135916
99999
62543
32101
71086
53902
50414
55300
56601
930G
948-E
911-E
948-W
61019
911-W
33001
35913
62501
65672
930S
45134
43609
42116
62517
62515
62526
62527
62503
62513
61289
62542
62501OK
11289
62501
15930
15908
15904
15904
15908
15908
15904
15904
15908
62502
41046
62501
62514
62501
61018
71089
45134
96022
43120
41157
44045
45815
40592
43610
62522
41163
15930
15930
11824
SE 74th St
SE 59th St.
Ai r D ep ot
St af f D r.
"A " A ve
M un iti on s R d.
W ar eh ou se R d.
"B " A ve
"H " A ve
M cN ar ne y Av e.
Al er t R d.
"E "A ve
Sentry Rd.
5th Ave.
Jo ne s
To w er R d.
Vanaman Rd.
So ut h St
Ai r D ep ot
Ai r D ep ot
Rapcon Rd.
Reserve Rd
Mercury Rd.
O ld
A ir
De po t
Airey Dr.
General Motors Dr
Vandenberg Dr.
Hi llt op R d.
Dormitory Rd.
Chennault Dr.
M itc he ll A ve
Spaatz Dr.
3rd Ave.
Ai r D ep ot
B lv d
Turbine Dr.
Central Plant Dr.
6th St.6th St.
Blackb ird
Dr.
Thunderbolt D r.
Munitions Rd. Ext.
Codding Rd.
Starlifter Dr.
Co rs ai r D r.
Ra pt or Ct
N ig ht H aw k
Ct
Fr an kl in
Po w er ho us e
Dr
Sk ym as te r D r.
Spaatz Ct.
M un de ll
Nabors Dr.
M cN ickle
Ta il
Fe at he r D r.
Holden Dr.
Smith Ct.
Air Dep ot
1st St.
TAXIWAY F
Mercury Rd.
Ra ily ar d
Rd
He rc ul es
R d.
"F " A ve
96021
Arnold St.
Ea st
D r.
Patrol Rd.
Reserve Rd.
5th Ave
7th St.
Mitchell Ave
Co ok
A ve
W es t D r.
Extender Dr.
34th St.
Twining Dr.
Globemaster Dr.
In du st ria l B lv d.
1st St.
Do ol itt le
A ve
Pi cn ic R d.
Ja m es D r.
W ol fe D r.
"D " A ve
Perimeter Rd.
"L " A ve
1st St.
Br ow n Dr
Po nd
R d.
Bradley Dr.
Entrance Road "C"
Entrance Road "A"
"C " A ve
"C " A ve
Do rm ito ry
R d.
"M " A ve
Co m m od ity D r.
Doolittle Ave
W hi te D r.
"D " D riv e
Ba ll
Pa rk
R d.
Joint STARS Dr.
Turbine Dr.
Falco n Dr.
W ey la nd
L oo p
Pegasus Dr.
Chidlaw Ct.
Ph an to m
D r.
La w re nc e
In tr ud er
D r.
M cN ic kl e
M ill er D r.
Ai re y C ir.
Ra ve n Ct
. Ai r D ep ot
Vanaman Rd.
1st St.
Ra w li ng s A ve
Mitc he ll A ve
Pr op ul sio n Dr
Stratofortress Dr.
Arnold St.
TINKER AFB, OK
VICINITY MAP
CONTRACTING
B3
GOTT
GATE
TINKER GATE
PASS & ID B6611
EAKER GATE
FIRE DEPARTMENT
B117
VANCE
GATE
LIBERATOR GATE
HOPE
GATE
LEGEND
CONTRACTOR
HAUL ROUTE
LANCER
GATE
TRUCK GATE
PIAZZA GATE
BASE CIVIL
ENGINEER
B400
PROJECT
LOCATION
BASE
OPERATIONS
B240
HRUSKOCY
GATE
GENERAL NOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
2. DEMOLISH EXISTING ALARM NOTIFICATION DEVICES AND HEAT DETECTORS AS
IDENTIFIED IN THE PROJECT DOCUMENTS.
3. DEMOLISH CIRCUITS BACK TO THE CONTROL PANEL. DO NOT ABANDON IN PLACE.
FP-101
FIRE ALARM DEMO PLAN
SCALE: 1/16" = 1'-0"
OF
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
DESIGN
BUILD
W W
YK
IN
ST
AL
L M
NS
R
EP
LA
CE
HE
AT
D
ET
EC
TO
RS
, B
AP
R
IL
TE
PA
-S R
M
A M
C
PE
R
SO
N
FD101
N B
IR
C
H U
M
En gr
\D es ig n\ s\
\2
0\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
FI
RE
A
LA
RM
D
EM
O
PL
AN
02 03
B976 KEY PLAN
S
S
FIRE ALARM CONTROL PANEL
FIRE SUPPRESSION RELEASING PANEL
FIRE ALARM SYSTEM ANNUNCIATOR
NOTIFICATION APPLIANCE POWER SUPPLY PANEL
120 VOLT POWER DISTRIBUTION PANEL
TRANSIENT VOLTAGE SURGE SUPPRESSOR
REMOTE TEST AND ALARM INDICATOR STATION
ELECTROMAGNETIC DOOR LOCK
MANUAL PULL STATION
ADDRESSABLE OUTPUT
ADDRESSABLE INPUT
CIRCUIT ISOLATOR MODULE
RELAY
PHOTOELECTRIC SMOKE DETECTOR
FIXED TEMPERATURE HEAT DETECTOR (135° NOMINAL ALARM TEMP)
PHOTOELECTRIC DUCT SMOKE DETECTOR
SMOKE DAMPER
FLOW INDICATION SWITCH
VALVE TAMPER SWITCH
FIRE SPRINKLER RISER
CEILING MOUNTED SPEAKER STROBE
CEILING MOUNTED STROBE
WALL MOUNTED SPEAKER STROBE
DESCRIPTIONSYMBOL
ELECTROMAGNETIC DOOR HOLDER
12 AWG, 120 VOLT, SINGLE POLE, 20 AMP, DEDICATED POWER CIRCUIT
2 CONDUCTOR, LOW-VOLTAGE CIRCUIT
CARBON MONOXIDE DETECTOR
FIRE ALARM MODULE
LIGHTNING ARRESTOR & DISCHARGE ASSEMBLY
MASS NOTIFICATION RECEIVER PANEL ANTENNA
AIR HANDLING UNIT MOTOR STARTER / UNIT CONTROLLER
CEILING MOUNTED SPEAKER
ANSUL FIRE SUPPRESSION CONTROL PANEL
ULTRAVIOLET AND INFRARED FIRE DETECTOR
CEILING MOUNTED HORN STROBE
WALL MOUNTED HORN STROBE
WALL MOUNTED SPEAKER
WALL MOUNTED STROBE
MANUAL ACTIVATION BUTTON / SWITCH
MANUAL ABORT BUTTON / SWITCH
MONACO TRANSCEIVER PANEL
KEY BOX / KNOX BOX
ALARM SYSTEM SYMBOLS
FACP
F
FSRP
FAA
NAP
120V
TVSS
RTS
MAG
LAD
A
ANSUL
AI
AO
CI
R
CO
M
M
A
MON
KB
MASS NOTIFICATION LOCAL OPERATOR CONSOLELOC
KEYED NOTES
EXISTING FIRE ALARM CONTROL PANELS
CLASS 1 DIVISION 1 ELECTRICALLY CLASSIFIED AREA WITHIN THE HANGAR
BAY FROM THE FLOOR TO THE TOP OF THE HANGAR DOOR.
CLASS 1 DIVISION 1 ELECTRICAL CLASSIFICATION.
33 3 3
PAINT PREP PAINT ROOM
WASH
RACK
CELL
ROOM
CO
RR
OS
IO
N
FOAM
ROOM
FOAM
ROOM
FOAM
ROOM
BREAK
ROOM
TOOL
ROOM
MECH
ROOM
SERVER
ROOM
BREAK
ROOM
AF RESERVE
OFFICE
FOAM
ROOM
FUEL SYSTEMS
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
I
J
K
L
M
N
CORRIDOR
WOMEN
MEN
LO
UN
GE
FA
C
P
FS
R P
N
AP
M O
N
CEILING HEAT
DETECTOR ZONE 1
CEILING HEAT
DETECTOR ZONE 2
CEILING HEAT
DETECTOR ZONE 3
GENERAL NOTES
KEYED NOTES
1. THE DRAWING WAS PREPARED FROM EXISTING DRAWINGS AND LIMITED ACCESS
FOR FIELD OBSERVATIONS. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS FOR ACCURACY.
2. PROVIDE A NEW FIRE ALARM AND MASS NOTIFICATION SYSTEM THROUGHOUT THE
FACILITY.
3. PROVIDE APPROVED PENETRATIONS THROUGH FIRE RATED CONSTRUCTION PER
THE TINKER AIR FORCE BASE FIRE PROTECTION STANDARDS.
4. 100% ACCEPTANCE TEST SHALL BE PROVIDED.
5. CODE REFERENCES:
5.1. UFC 1-200-01, DOD BUILDING CODE, WITH CHANGE 4.
5.2. UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, WITH CHANGE
6.
5.3. UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS,
WITH CHANGE 3.
5.4. UFC 4-021-01, DESIGN O&M: MASS NOTIFICATION SYSTEMS, WITH CHANGE 1.
5.5. UFC 4-211-01, AIRCRAFT MAINTENANCE HANGARS, WITH CHANGE 3.
5.6. UFC 4-211-02, AIRCRAFT CORROSION CONTROL AND PAINT FACILITIES.
5.7. TINKER AIR FORCE BASE FIRE PROTECTION STANDARD.
5.8. NFPA 70, NATIONAL ELECTRIC CODE.
5.9. NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE.
5.10. NFPA 400, HAZARDOUS MATERIALS CODE.
FP-101
FIRE ALARM / MASS NOTIFICATION PLAN
SCALE: 1/16" = 1'-0"
OF
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TINKER AFB, OK
DESIGN
BUILD
W W
YK
IN
ST
AL
L M
NS
R
EP
LA
CE
HE
AT
D
ET
EC
TO
RS
, B
AP
R
IL
TE
PA
-S R
M
A M
C
PE
R
SO
N
FA101
N B
IR
C
H U
M
En gr
\D es ig n\ s\
\2
0\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
FI
RE
A
LA
RM
A
ND
M
AS
S
NO
TI
FI
CA
TI
ON
P
LA
N
03 03
B976 KEY PLAN
S
S
FIRE ALARM CONTROL PANEL
FIRE SUPPRESSION RELEASING PANEL
FIRE ALARM SYSTEM ANNUNCIATOR
NOTIFICATION APPLIANCE POWER SUPPLY PANEL
120 VOLT POWER DISTRIBUTION PANEL
TRANSIENT VOLTAGE SURGE SUPPRESSOR
REMOTE TEST AND ALARM INDICATOR STATION
ELECTROMAGNETIC DOOR LOCK
MANUAL PULL STATION
ADDRESSABLE OUTPUT
ADDRESSABLE INPUT
CIRCUIT ISOLATOR MODULE
RELAY
PHOTOELECTRIC SMOKE DETECTOR
FIXED TEMPERATURE HEAT DETECTOR (135° NOMINAL ALARM TEMP)
PHOTOELECTRIC DUCT SMOKE DETECTOR
SMOKE DAMPER
FLOW INDICATION SWITCH
VALVE TAMPER SWITCH
FIRE SPRINKLER RISER
CEILING MOUNTED SPEAKER STROBE
CEILING MOUNTED STROBE
WALL MOUNTED SPEAKER STROBE
DESCRIPTIONSYMBOL
ELECTROMAGNETIC DOOR HOLDER
12 AWG, 120 VOLT, SINGLE POLE, 20 AMP, DEDICATED POWER CIRCUIT
2 CONDUCTOR, LOW-VOLTAGE CIRCUIT
CARBON MONOXIDE DETECTOR
FIRE ALARM MODULE
LIGHTNING ARRESTOR & DISCHARGE ASSEMBLY
MASS NOTIFICATION RECEIVER PANEL ANTENNA
AIR HANDLING UNIT MOTOR STARTER / UNIT CONTROLLER
CEILING MOUNTED SPEAKER
ANSUL FIRE SUPPRESSION CONTROL PANEL
ULTRAVIOLET AND INFRARED FIRE DETECTOR
CEILING MOUNTED HORN STROBE
WALL MOUNTED HORN STROBE
WALL MOUNTED SPEAKER
WALL MOUNTED STROBE
MANUAL ACTIVATION BUTTON / SWITCH
MANUAL ABORT BUTTON / SWITCH
MONACO TRANSCEIVER PANEL
KEY BOX / KNOX BOX
ALARM SYSTEM SYMBOLS
FACP
F
FSRP
FAA
NAP
120V
TVSS
RTS
MAG
LAD
A
ANSUL
AI
AO
CI
R
CO
M
M
A
MON
KB
MASS NOTIFICATION LOCAL OPERATOR CONSOLELOC
EXISTING FIRE ALARM CONTROL PANELS. PROVIDE 120 VOLT, 20 AMP
DEDICATED CIRCUIT FOR THE NEW NOTIFICATION PANEL.
CLASS 1 DIVISION 1 ELECTRICALLY CLASSIFIED AREA WITHIN THE HANGAR
BAY FROM BELOW THE FLOOR TO THE TOP OF THE HANGAR DOOR.
CLASS 1 DIVISION 1 ELECTRICAL CLASSIFICATION.
3 3 3
3 3
PAINT PREP PAINT ROOM
WASH
RACK
CELL
ROOM
CO
RR
OS
IO
N
FOAM
ROOM
FOAM
ROOM
FOAM
ROOM
BREAK
ROOM
TOOL
ROOM
MECH
ROOM
OFFICE OFFICE
AF RESERVE
OFFICE
FOAM
ROOM
OFFICE
1 2 3 4 5 6 7 8 9 10 11 12
A
B
C
D
E
F
G
H
I
J
K
L
M
N
CORRIDOR
WOMEN
MEN
LO
UN
GE
| 01-230170-G101 |
| Sheets and Views |
| G101 |
| 02-230170-FD101 |
| Sheets and Views |
| FD101 |
| LEGEND |
| 03-230170-FA101 |
| Sheets and Views |
| FA101 |
File details come from the government source that posted it. Updated .