Att.1_Exhibit_A-1_-_Specifications.docx
DOCX document 44 KB Posted
- Attached to
- ADA Wheelchair Lift Van Conversion
- Solicitation number
- 0000038047
- Issued by
- California
About this file
This is a technical specification document issued by the California Department of Corrections and Rehabilitation (CDCR) for wheelchair lift van conversions under solicitation 2310-TS-0302083-1. The specification establishes minimum requirements for the installation of a rear door accessible wheelchair lift into a Ford Transit XL, Medium Roof, 15-passenger van. The converted van must safely transport two wheelchair-bound inmates and be equipped with new, unused, current-year model components. The specification references applicable regulations including the Americans with Disabilities Act (ADA), California Vehicle Code (CVC), Federal Motor Vehicle Safety Standards (FMVSS), and standards from organizations such as the American Society of Mechanical Engineers (ASME) and the Society of Automotive Engineers (SAE).
The wheelchair lift must be either a Braun Century Series model #NDCC-2 or Ricon titanium type for rear door installation in non-folding style. The lift must meet specific technical requirements including a minimum lifting capacity of 800 pounds, maximum clear height of 58 inches, minimum platform width of 31 inches, minimum platform length of 43 inches, and minimum floor-to-ground travel of 40 inches. The lift must comply with ADA Standards for Accessible Design and FMVSS regulations for platform lift systems and installations. All components must be complete, ready to use, and conform to the highest standards of engineering practices. Bids must be submitted in writing to OTA@DGS.COM, with inquiries directed to Procurement Official Phebe Lapinig or backup Jennifer Maier at the California Department of General Services.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| STD_204.pdf | ||
| IFB_38047_Wheelchair_Van_Conversion.docx | DOCX document | |
| Att.1_Exhibit_C_-_Admin_Requirements.docx | DOCX document | |
| Att.1_Exhibit_G_-_Insurance_and_Liability_Terms.docx | DOCX document | |
| Att.1_Exhibit_E_-_Van_Inspection_Form.docx | DOCX document | |
| Att.1_Exhibit_B_-_Cost_Worksheet.docx | DOCX document | |
| Att.3_IFB_Narrative_Response_Form.docx | DOCX document | |
| Agreement_Cover_Letter.docx | DOCX document | |
| Att.1_Exhibit_F_-_Authorized_Warranty_Repair.docx | DOCX document | |
| Att.2_Cost_Worksheet.xlsx | XLSX spreadsheet | |
| Att.1_Exhibit_A_-_Statement_of_Work.docx | DOCX document | |
| Att.4_Van_Wheelchair_Lift_Drawings.docx | DOCX document | |
| Att.1_Exhibit_D_-_Work_Authorization_Form.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
| STATE OF CALIFORNIA | 2310-TS-0302083-1 | |
| Technical Specification | Attachment 1 – Exhibit A-1 | |
| Wheelchair Lift Van Conversions |
Scope It is the intent of this technical specification to describe the minimum requirements for the installation of a rear door accessible wheelchair lift into a Ford Transit XL, Medium Roof, 15 passengers Van, supplied by the California Department of Corrections and Rehabilitation (CDCR). The converted van shall be capable of safely transporting two wheelchair bound inmates.
All installed components shall be new, unused, current year model and will have all standard equipment shown in the manufacturers printed literature unless a specific and installed option makes the standard equipment unnecessary.
Regulations, Codes, and Standards The following standards, laws, regulations, and codes of the issue in effect on the date of the Invitation for Bid (IFB) form a part of this specification to the extent specified herein. Any referenced document is the current edition, as of the date of the issuance of this specification.
Regulations Americans with Disabilities Act (ADA) American Public Transportation Association (APTA) California Department of Transportation (Caltrans) California Vehicle Code (CVC) Code of Federal Regulations (CFR) Federal Motor Vehicle Safety Standards (FMVSS) U.S. Department of Transportation (U.S. DoT) Standards American Society of Mechanical Engineers (ASME) American Society for Testing and Materials (ASTM) International American National Standards Institute (ANSI) International Organization for Standardization (ISO) Society of Automotive Engineering (SAE) International Technical Requirements General The wheelchair lift shall be new, unused, and current production as specified in the solicitation at the line-item description. Products bid shall meet or exceed the requirements in the solicitation line-item description. The wheelchair lift shall be supplied with all equipment and accessories indicated as standard equipment in the manufacturer’s published literature or website.
The wheelchair lift shall include all necessary equipment, be complete, and ready to use. All parts not specifically mentioned which form part of the complete unit required for functionality shall be provided and shall conform in design, strength, quality of materials, and workmanship to the highest standards of engineering practices.
ACCESSIBILITY
The wheelchair lift shall comply with ADA Standards for Accessible Design, including all requirements of Sections 206.7 (Platform Lift Use) and 410 (Platform Lift Technical Criteria
SAFETY
The wheelchair lift shall comply with FMVSS 49 CFR § 571.403 (Platform Lift Systems) and 49 CFR § 571.404 (Platform Lift Installations)
TYPE
The wheelchair lift shall be the Braun Century Series model #NDCC-2 or Ricon titanium.
STYLE
The wheelchair lift shall be for rear door installation and shall not be folding style.
LOAD CAPACITY
The wheelchair lift shall have a minimum lifting capacity of 800 pounds.
Clear HEIGHT The wheelchair lift shall have a maximum clear height of 58 inches.
Clear PLATFORM WIDTH The wheelchair lift shall have a minimum platform width of 31 inches.
Clear PLATFORM LENGTH The wheelchair lift shall have a minimum platform length of 43 inches.
FLOOR-TO-GROUND TRAVEL
The wheelchair lift shall have a minimum floor-to-ground travel of 40 inches.
Revision History