This is a permit set of architectural drawings for the Oregon City High School Career and Technical Education (CTE) renovation project, a collaborative effort between Oregon City School District No. 62, BRIC Architecture Inc. (architect), KPFF (structural engineer), Interface Engineering (mechanical, plumbing, fire protection, and electrical engineers), Coffman Engineers (audio/visual and technology design), and Otak CPM (project management). The project involves the renovation of existing faculty spaces and classroom areas into career technology vocational training spaces and a college and career center at 19761 S Beavercreek Road, Oregon City, OR 97045. The scope includes four primary vocational classroom areas (Intro to Robotics, Intro to Digital Media, JROTC, and Intro to Trades), support spaces (production studio, control room, podcasting/recording room, storage areas, and offices), and related building systems modifications. The permit set comprises comprehensive architectural plans including floor plans, reflected ceiling plans, interior elevations, casework details, signage plans, and wall type specifications across two levels, with demolition plans indicating removal of existing fixtures, finishes, and non-structural elements while maintaining structural integrity of the existing 2004-constructed facility. The project is classified as Group E Educational Occupancy under Oregon Structural Specialty Code (OSSC) 2022, utilizing Type II-A construction and including automatic sprinkler systems and fire alarm modifications.

The design incorporates specialized acoustic assemblies with Sound Transmission Class (STC) ratings of 50-56 for noise-sensitive areas, impact-resistant gypsum board up to 4 feet above finished floor throughout, multiple wall types ranging from single-layer to double-layer configurations with acoustic insulation, and various finish materials including polished concrete, carpet tile, sheet linoleum, and rubber base. Interior finishes feature plastic laminate casework, laboratory-grade compact laminate countertops in specific areas, acoustic wall panels, tackable surfaces, and custom perforated metal panels. The project includes custom dimensional signage with perforated channel lettering, specialized window coverings (roller and blackout shades), and multiple casework types with adjustable shelving and fixed components. Building systems modifications encompass mechanical, plumbing, electrical, and technology infrastructure updates to support the new educational uses, with references to delegated design components requiring deferred submittals in structural, mechanical, plumbing, electrical, and audio-visual categories. The permit set indicates this is a renovation project that does not increase the building's overall square footage and maintains all existing exits, with construction documents dated January 30, 2026.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

ROOM NAME & NUMBER

STOREFRONT OR

WINDOW TYPE

KEYNOTE REFERENCE

CEILING PLANE HEIGHT -

ALL REFERENCES TO FINISH

FLOOR ELEVATION

INTERIOR FINISH TYPE

HORIZONTAL ELEVATION

PLANE HEIGHT -

ALL REFERENCES TO

F.F. ELEVATION

SPOT ELEVATION -

ALL REFERENCES TO

F.F. ELEVATION UNO

DOOR NUMBER -

SEE DOOR SCHEDULE

RELITE NUMBER -

SEE RELITE SCHEDULE

GRID LINE

BUILDING

SECTION

EXTERIOR

ELEVATION

INTERIOR

ELEVATION

REVISION CLOUD

ENLARGED PLAN /

DETAIL

DETAIL SECTION0' - 0"

TB-1

0'-0"

LEVEL 1

N U

M

BE

R

A101

A101

REV #

A3.01

A5.01

1A

1B

1C

1D

WALL SECTION1

A101

SIM

SIM

NORTH ARROW

MATCHLINE

MATCHLINE SEE A0.11

1t

Room name

NUMBER

SHEET NORTH

PROJECT NORTH

0'-0" T.O.S.

FRAMELESS RELITE NUMBER -

SEE RELITE SCHEDULE

NUMBER

A101

A101

WALL TYPEA1

CL

ACT

ADA

ADD

AESS

AFF

AHJ

ALUM

ANOD

BD

BLDG

BLKG

BM

BO

BOD

BTWN

CAB

CG

CIP

CL

CLG

CLR

CJ

CMU

CONT

CSJ

CSMT

CT

CTR

DBL

DTL

DF

DIA

DIAG

DIM

DN

DR

DS

DW

DWG

(E)

EA

EF

ANGLE

AND

ACOUSTICAL CEILING TILE

AMERICANS WITH DISABILITY

ACT STANDARDS (2010)

ADDENDUM

ARCHITECTURAL EXPOSED

STRUCTURAL STEEL

ABOVE FINISH FLOOR

AUTHORITY HAVING

JURISDICTION

ALUMINUM

ANODIZED

BOARD

BUILDING

BLOCKING

BENCH MARK

BOTTOM OF

BOTTOM OF DECK

BETWEEN

CONTINUOUS AIR BARRIER

CORNER GUARD

CAST IN PLACE CONCRETE

CENTERLINE

CEILING

CLEAR

CONTROL JOINT

CONCRETE MASONRY UNIT

CONTINUOUS

CONSTRUCTION JOINT

CASEMENT

CERAMIC TILE

CENTER

CENTERLINE

DOUBLE

DETAIL

DRINKING FOUNTAIN

DIAMETER

DIAGONAL

DIMENSION

DOWN

DOOR

DOWNSPOUT

DISHWASHER

DRAWING

EXISTING

EACH

EXHAUST FAN

EJ

EL

ELEC

EJC

EOS

ENGR

EQ

EQUIP

ES

EXP

EXT

FA

FD

FDN

FE

FEC

FECB

FF

FIN

FL

FO

FOC

FOF

FOM

FOS

FRT

FTG

FURR

GA

GALV

GB

GC

GL

GND

GVP

GYP

HB

HM

HPC

HVAC

HW

INSUL

INT

IFP

EXPANSION JOINT

ELEVATION

ELECTRICAL

EXPANSION JOINT COVER

EDGE OF SLAB

ENGINEER

EQUAL

EQUIPMENT

EACH SIDE

EXPANSION

EXTERIOR

FIRE ALARM

FLOOR DRAIN

FOUNDATION

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER CABINET

W/ BLANKET

FINISH FLOOR

FINISH

FLOOR

FACE OF

FACE OF CONCRETE

FACE OF FINISH

FACE OF MASONRY

FACE OF STUD/STRUCTURE

FIRE RETARDANT TREATED

FOOTING

FURRING

GAUGE/GAGE

GALVANIZED

GRAB BAR

GENERAL CONTRACTOR

GLASS/GLAZING

GROUND

GYPSUM VENEER PLASTER

GYPSUM

HOSE BIBB

HOLLOW METAL

HIGH PERFORMANCE COATING

HEATING, VENTILATION AND

AIR CONDITIONING

HOT WATER

INSULATION

INTERIOR

INTUMESCENT FIRE

PROTECTION

JT

JST

LAV

LKR

LVR

MATL

MB

MAX

MECH

MEZZ

MFR

MIN

MISC

MTD

MO

MTL

(N)

NA

NIC

NOM

NTS

OA

OC

OD

OFCI

OFD

OFOI

OH

OPNG

OPP

OS

PL

PLAM

PLAS

PLYWD

PT

PVMT

R

RD

REF

REFR

REQ'D

REV

RO

RT

RCP

JOINT

JOIST

LAVATORY

LOCKER

LOUVER

MATERIAL

MARKERBOARD

MAXIMUM

MECHANICAL

MEZZANINE

MANUFACTURER

MINIMUM

MISCELLANEOUS

MOUNTED

MASONRY OPENING

METAL

NEW

NOT APPLICABLE

NOT IN CONTRACT

NOMINAL

NOT TO SCALE

OVERALL

ON CENTER

OUTSIDE DIAMETER

OWNER FURNISHED

CONTRACTOR INSTALLED

OVERFLOW DRAIN

OWNER FURNISHED OWNER

INSTALLED

OVERHEAD

OPENING

OPPOSITE

OUTSIDE

PROPERTY LINE

PLASTIC LAMINATE

PLASTER

PLYWOOD

PRESSURE TREATED

PAVEMENT

RADIUS

ROOF DRAIN

REFERENCE

REFRIGERATOR

REQUIRED

REVISE OR REVISION

ROUGH OPENING

ROOF TIE-OFF

REFLECTED CEILING PLAN

ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLSROOM ABBREVIATIONS

CR

CORR

ELEC

IDF

LG

MP

OFC

RR

RM

SM

ST

STOR

STR

U

CLASSROOM

CORRIDOR

ELECTRICAL

INTERMEDIATE DISTRIBUTION FRAME

LARGE

MULTI-PURPOSE

OFFICE

RESTROOM

ROOM

SMALL

STAFF TOILET

STORAGE

STAIR

UTILITY

SAHTS

SAM

SC

SECT

SF

SFRM

SHTG

SHWR

SHT

SIM

SJ

SOG

SQ

SS

STD

STL

STRUCT

SUSP

T/M

THK

TLT

TO

TOC

TOD

TOS

TJ

TP

TS

TYP

T&G

UNFIN

UNO

VB

VERT

VIF

VR

VFY

W/ W/O

WC

WD

WF

WH

WP

WRB

WT

SELF ADHERED HIGH

TEMPERATURE SHEET

SELF-ADHERED MEMBRANE

SOLID CORE

SECTION

SQUARE FOOT

SPRAY-APPLIED FIRE

RESISTIVE MATERIALS

SHEATHING

SHOWER

SHEET

SIMILAR

SEISMIC JOINT

SLAB ON GRADE

SQUARE

STAINLESS STEEL

STANDARD

STEEL

STRUCTURAL

SUSPENDED

TO MATCH

THICK

TOILET

TOP OF

TOP OF CURB

TOP OF DECK

TOP OF STRUCTURE

TOOL JOINT

TOILET PAPER

TUBE STEEL

TYPICAL

TONGUE AND GROOVE

UNFINISHED

UNLESS NOTED OTHERWISE

VAPOR BARRIER

VERTICAL

VERIFY IN FIELD

VAPOR RETARDER

VERIFY

WITH

WITHOUT

WATER CLOSET

WOOD

WIDE FLANGE

WATER HEATER

WATERPROOFING

WATER-RESISTIVE BARRIER

WEIGHT

VICINITY MAP

PERMIT SET

LIST IS NOT INCLUSIVE; OTHER ABBREVIATIONS MAY DEFINED BY DISCIPLINE OR BY INDIVIDUAL SHEET. WHERE IN CONFLICT, SUCH ABBREVIATIONS SUPERCEDE THOSE INDICATED IN THIS LIST.

JAN 30, 2026

DELEGATED DESIGN

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

OREGON CITY HIGH SCHOOL CTE

OREGON CITY SCHOOL DISTRICT

19761 S BEAVERCREEK RD, OREGON CITY, OR 97045

PROJECT # 25003-154

ARCHITECTURE

A0.03 CODE ANALYSIS - LEVEL 1

A0.05 WALL TYPES & ACOUSTIC ASSEMBLIES

A0.11 OVERALL FLOOR PLAN - LEVEL 1

A0.12 OVERALL FLOOR PLAN - LEVEL 2

A1.11 DEMO PLANS

A1.12 DEMO PLANS

A1.21 DEMO REFLECTED CEILING PLANS

A1.22 DEMO REFLECTED CEILING PLANS

A2.11 FLOOR PLANS

A2.12 FLOOR PLANS

A4.11 FINISH FLOOR PLANS

A4.12 FINISH FLOOR PLANS

A5.01 INTERIOR ELEVATIONS - HALLWAYS

A5.20 INTERIOR ELEVATIONS - SECTOR B

A5.30 INTERIOR ELEVATIONS - SECTOR C

A5.40 INTERIOR ELEVATIONS - SECTOR D

A5.90 INTERIOR ELEVATIONS - SECTOR J

A6.11 REFLECTED CEILING PLANS

A6.12 REFLECTED CEILING PLANS

A8.01 DOORS AND RELITES

A9.10 CASEWORK DETAILS

A9.11 CASEWORK DETAILS

A9.12 CASEWORK DETAILS

A9.20 INTERIOR DETAILS - FLOORS AND MOBILE CASEWORK

A9.30 INTERIOR DETAILS - WALLS

A9.31 INTERIOR DETAILS - CEILINGS

A9.70 SIGNAGE PLAN

A9.71 SIGNAGE TYPES AND SCHEDULE

MECHANICAL

M0.01 SYMBOL LIST AND GENERAL NOTES - MECHANICAL

M0.02 SCHEDULES - MECHANICAL

M0.11 OVERALL FLOOR - LEVEL 1 - MECHANICAL

M0.12 OVERALL FLOOR PLAN - LEVEL 2 - MECHANICAL

M1.11 DEMO PLANS - MECHANICAL

M1.12 DEMO PLANS - MECHANICAL

M2.11 FLOOR PLANS - MECHANICAL

M2.12 FLOOR PLANS - MECHANICAL

M7.01 DETAILS - MECHANICAL

PLUMBING

P0.01 SYMBOL LIST AND GENERAL NOTES - PLUMBING

P0.02 SCHEDULES - PLUMBING

P0.11 OVERALL FLOOR PLAN - LEVEL 1 - PLUMBING

P0.12 OVERALL FLOOR PLAN - LEVEL 2 - PLUMBING

P1.11 DEMO PLANS - PLUMBING

P1.12 DEMO PLANS - PLUMBING

P2.11 FLOOR PLANS - PLUMBING

P2.12 FLOOR PLANS - PLUMBING

ELECTRICAL

E0.01 SYMBOL LIST AND GENERAL NOTES - ELECTRICAL

E0.02 LUMINAIRE SCHEDULE - ELECTRICAL

E0.11 OVERALL FLOOR PLAN - LEVEL 1 - ELECTRICAL

E0.12 OVERALL FLOOR PLAN - LEVEL 2 - ELECTRICAL

E1.11 DEMO PLANS - POWER & SIGNAL

E1.12 DEMO PLANS - POWER & SIGNAL

E1.21 DEMO REFLECTED CEILING PLANS - LIGHTING

E1.22 DEMO REFLECTED CEILING PLANS - LIGHTING

E2.11 FLOOR PLANS - POWER & SIGNAL

E2.12 FLOOR PLANS - POWER & SIGNAL

E6.11 REFLECTED CEILING PLANS - LIGHTING

E6.12 REFLECTED CEILING PLANS - LIGHTING

E9.01 PANEL SCHEDULES - ELECTRICAL

E9.02 PANEL SCHEDULES - ELECTRICAL

1.

2.

3.

4.

5.

6.

Seismic Anchorage of Architectural Wood Casework, Section 06 41 00.

Firestopping, Section 07 84 00.

Seismic Anchorage for Acoustic Ceilings, Section 09 51 00

Seismic Anchorage for Mechanical, Plumbing, and Electrical Equipment and Components, Divisions 21, 22, 23, 26, 27, and 28.

Fire Suppression, Division 21.

Fire Alarm Systems, Division 28.

Oregon City School District 1417 12th St.

Oregon City, Oregon 97045 t: (503) 785 8531

David Hobbs owner

Otak CPM 808 SW Third Ave., Suite 800

Portland, Oregon 97204 t: (503) 287 6825 Brian Hardebeck project manager

KPFF

111 SW 5th Ave., Suite 2500

Portland, Oregon 97204 t: (503) 764 0531 Paige Kabusreiter structural engineer

Interface Engineering 100 SW Main St Suite 1600

Portland, Oregon 97204 t: (503) 382 2266

Jim McClelland mechanical engineer

Interface Engineering 100 SW Main St Suite 1600

Portland, Oregon 97204 t: (503) 382 2266

Todd Kolibaba plumbing engineer

Interface Engineering 100 SW Main St Suite 1600

Portland, Oregon 97204 t: (503) 382 2266

Jane Jackson fire protection engineer

Interface Engineering 100 SW Main St Suite 1600

Portland, Oregon 97204 t: (503) 382 2266

Kristin Melling electrical engineer

Interface Engineering 100 SW Main St Suite 1600

Portland, Oregon 97204 t: (503) 382 2266

Todd Shenbeck technology & low voltage

Coffman Engineers 1101 2nd Ave., Suite 400

Seattle, Washington 98101 t: (206) 623 0717

Jaimie Penzell acoustical engineer

Julie Jenson / graphic design 1209 N. Morgan St.

Portland, Oregon 97217 t: (503) 545 4968

Julie Jenson graphic design

BRIC Architecture Inc.

1233 NW Northrup Street, Suite 100

Portland, Oregon 97209 t: (503) 595 4900

BRIC Contact architect

STRUCTURAL

S0.01 DRAWING INDEX AND LIST OF ABBREVIATIONS

S0.02 GENERAL STRUCTURAL NOTES

S0.03 SPECIAL INSPECTIONS AND TESTING

S0.04 LIVE LOADING PLANS

S0.11 OVERALL PLAN - LEVEL 1

S0.12 OVERALL PLAN - LEVEL 2

S2.11 PARTIAL PLANS

S2.12 PARTIAL PLANS

S6.01 DETAILS

S6.02 DETAILS

DELEGATED DESIGN COMPONENTS WHICH REQUIRE

DEFERRED SUBMITTALS INCLUDE, BUT NOT LIMITED

TO, THE FOLLOWING:

Coffman Engineers 1101 2nd Ave., Suite 400

Seattle, Washington 98101 t: (206) 623 0717

John Hardwich audio & visual design

AUDIO VISUAL

AV0.01 PRODUCTION STUDIO LEGENDS

AV2.11 PRODUCTION STUDIO AV SYSTEMS PLANS

AV3.0 PRODUCTION STUDIO AV SYSTEM DETAILS

AV5.30 PRODUCTION STUDIO AV SYSTEM ELEVATIONS

AV10.1 PRODUCTION STUDIO BLOCK DIAGRAM

UP

DN

DN

LEGEND

EXISTING 1 HOUR FIRE RATED ASSEMBLY

EXISTING 2 HOUR FIRE RATED ASSEMBLY

AREA NOT IN SCOPE

AREA OF ALTERATION

OCCUPANTS

NUMBER OF OCCUPANTS & DIRECTION OF TRAVEL

ACCESSORIES OCCUPANCIES: (OCCUPANTS NOT

INCLUDED IN OCCUPANT LOAD FOR EXITING)

980 20 49 1

ROOM NAME

(FUNCTION OF SPACE

PER TABLE 1004.5)

EXIT CALCULATIONS

A 184

EXIT OCCUPANT

LOAD

REQUIRED

WIDTH

(INCHES)*

PROVIDED

WIDTH

(INCHES)

NOTES

B

REQUIRED EGRESS COMPONENT WIDTH WITH SPRINKLER SYSTEM PER OSSC

1005.3.2 EXCEPTION 1: OCCUPANT LOAD X 0.15 = MIN. WIDTH

*32" MIN AT 49 OR FEWER OCCUPANTS; 44" MIN AT 50 OR MORE OCCUPANTS

C

D

PATH OF EGRESS TO AN EXIT (TRAVEL DISTANCE

NOTED IN (XX') EQUALS TOTAL DISTANCE FOR

ROUTE) MAX. DISTANCE OF 250' PER TABLE 1017.2

XX'

X

EXIT SIGN LOCATIONS

(ARROWS INDICATE DIRECTIONAL EXIT SIGN)

SEE EXIT CALCULATIONS

FEC-1, FEC-2 FIRE EXTINGUISHER WITH CABINET

ROOM

AREA

OCCUPANT LOAD

FACTOR (TABLE 1004.1.2)

# OF EXITS REQUIRED

U: UTILITY, MEP, CUSTODIAL USE

S: STORAGE USE

T: TOILET ROOMS

*U *S *T

F

G

E

398 59.7

397 59.55

196 29.4

197 29.55

326 48.9

212 31.8

212 31.8

H 325 48.75 68

I 100 15 40

J

K

54 8.1

17 2.55

L

M

38 5.7

4 0.6

N 1 0.15 68

DIGITIAL MEDIA STUDIO

(VOCATIONAL)

INTRO TO ROBOTICS

(VOCATIONAL)

INTRO TO TRADES

(VOCATIONAL)

JROTC

(EXERCISE)

STORAGE

(STORAGE)

CONTROL ROOM

(VOCATIONAL)

PODCASTING

(VOCATIONAL)

STORAGE

(STORAGE)

STORAGE

(STORAGE)

OFFICE

(BUSINESS)

*U

*T *U

*T

*T

*S

*U

*T

*U

*T

*T

*T

*T

*T *U

*S

*S

*T

*T

ELEV

*T

*T

*U

*S *U

*U

G

F

H

E

D

C

A

*S

*S *S

*S

*S

B

325 326

100I

BB

AA

CC

EE

DD

ft

47 ft

AREA NOT IN SCOPEAREA NOT IN SCOPE

98 1

(E) 2-HR RATED

ASSEMBLIES AT

STRUCTURAL WALLS, TYP.

AT NONCONTINOUS

RATED WALLS.

J

D C

B E

CODE SUMMARY

APPLICABLE CODES

OREGON STRUCTURAL SPECIALTY CODE (OSSC) 2022

USE & OCCUPANCY

GROUP E

EXISTING HIGH SCHOOL BUILDING. REMODEL SCOPE INCLUDES

RENOVATION OF EXISTING FACULTY SPACES AND A CLASSROOM

TO CAREER TECHNOLOGY VOCATIONAL TRAINING SPACES AND A

COLLEGE AND CAREER CENTER. ALL EXISTING EXITS ARE

EXISTING TO REMAIN IN RENOVATION SCOPE.

FIRE PROTECTION

(E) AUTOMATIC SPRINKLER SYSTEM PER NFPA 13.

FIRE ALARM SYSTEM

(E) FIRE ALARM SYSTEM PRESENT.

ALLOWABLE AREA

SUMMARY:

BUILDING IS AN EXISTING SINGLE-STORY & DOUBLE STORY

COMBUSTABLE & NONCOMBUSTABLE CONSTRUCTION. ORIGINAL

BUILDING CONSTRUCTED 2004.

USE & OCCUPANCY:

EDUCATIONAL GROUP E

CONSISTING OF CLASSROOMS, CAFETERIA, AUDITORIUM &

GYMNASIUM.

CONSTRUCTION TYPE:

EXISTING CONDITION IN AREA OF WORK: TYPE II-A PER TABLE 601

REMODEL DOES NOT INCREASE SQUARE FOOTAGE OF BUILDING.

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :03

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A0.03

CODE ANALYSIS - LEVEL 1

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 3/64" = 1'-0" 1EGRESS PLAN - LEVEL 1

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

ENTIRE WALL ASSEMBLY SHALL EXTEND TO UNDERSIDE OF ROOF

OR FLOOR DECK ABOVE, UNLESS NOTED OTHERWISE.

SEE INTERIOR ELEVATIONS FOR LOCATION AND EXTENT OF APPLIED

WALL FINISHES.

EXTEND SOUND BATT INSULATION FULL HEIGHT OF WALL

ASSEMBLIES UNLESS NOTED OTHERWISE.

SEE STRUCTURAL DRAWINGS FOR WALL STUD SPACING.

PROVIDE MOISTURE RESISTANT GYPSUM BOARD ON ALL WALLS OF

TOILET ROOMS, KITCHEN AREAS, JANITOR CLOSETS AND BEHIND

DRINKING FOUNTAINS.

EXTEND ASSEMBLIES FOR FIRE RATED WALLS FROM STRUCTURAL

FLOOR TO UNDERSIDE OF FLOOR OR ROOF ABOVE UNLESS

SPECIFICALLY NOTED OTHERWISE. ALL OPENINGS SHALL BE

PROTECTED AS REQUIRED BY CODE.

AT FIREWALLS AND SMOKE BARRIERS ABOVE ACCESSIBLE CEILINGS,

PROVIDE IDENTIFICATION SIGNAGE, SPACED AT NOT MORE THAN 30

FEET MEASURED HORIZONTALLY, INDICATING “FIRE AND/OR SMOKE

BARRIER - PROTECT ALL OPENINGS”. SEE SIGNAGE TYPES.

PROVIDE FIRE BLOCKING IN CONCEALED SPACES OF STUD WALLS

AND PARTITIONS VERTICALLY AT THE CEILING AND FLOOR LEVELS

AND HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET.

SEE A0.05 FOR TYP. WALL INTERSECTION AND PENETRATION

DETAILS.

FOR STC ACOUSTIC WALLS, SEAL ALL PENETRATIONS AND GAPS

WITH ACOUSTIC SEALANT.

DO NOT INSTALL BACK-TO-BACK OUTLETS IN A WALL CAVITY. SEAL

ALL OPENINGS IN ELECTRICAL BOXES.

ALL NEW WALLS TO HAVE IMPACT RESISTANT WALLS UP TO 4'-0"

AFF.

WALL TYPES NOTES:

(1) LAYER TYPE "X" GYPSUM

BOARD BOTH SIDES (5/8"

UNO). IMPACT RESTISTANT

GYP BD UP TO 4' AFF.

FILL CAVITY WITH

ACOUSTIC INSULATION

METAL STUD FRAMING

FRAMING SIZES:

1a = 3.5" METAL STUDS 1b = 6" METAL STUDS 1c = 8" METAL STUDS

(2) LAYERS TYPE "X" GYPSUM

BOARD BOTH SIDES (5/8" UNO).

OUTSIDE LAYER IMPACT

RESISTANT GYP BD UP TO 4' AFF.

STAGGERED JOINTS.

FILL CAVITY WITH

ACOUSTIC INSULATION

METAL STUD FRAMING

FRAMING SIZES:

2a = 3.5" METAL STUDS 2b = 6" METAL STUDS 2c = 8" METAL STUDS

STC 54-56

(1) LAYER TYPE "X" GYPSUM

BOARD (5/8" UNO). IMPACT

RESISTANT GYP BD UP TO 4' AFF,

UNLESS WALL TYPE 3a*

FILL CAVITY WITH

ACOUSTIC INSULATION

METAL STUD FRAMING

FRAMING SIZES:

3a = 3.5" METAL STUDS 3a* = 3.5" METAL STUDS 3b = 6" METAL STUDS 3c = 8" METAL STUDS

1"

EXISTING WALL, FACE OF

FINISH WHERE OCCURS

WALL TYPE 3a* ADDITIONAL

LAYER TYPE "X" GYPSUM BOARD,

IMPACT RESISTANT GYP BD UP

TO 4' AFF. STAGGERED JOINTS.

MATCH (E) LAYERS TYPE "X"

GYPSUM BOARD BOTH SIDES

(5/8" UNO). OUTSIDE LAYER OF

GYP BD IMPACT RESISTANT

GYP BD UP TO 4' AFF.

STAGGER JOINTS WHERE (2)

LAYERS.

FILL CAVITY WITH

ACOUSTIC INSULATION

METAL STUD FRAMING

SIZE TO MATCH (E)

1" THICK MINIMUM 1.5 PCF

DENSITY GLASS OR MINERAL

FIBER

DUCT, SEE MECHANICAL

BACKER ROD WITH (2)

CONTINUOUS BEADS OF

ACOUSTIC SEALANT

AROUND FULL PERIMETER

OF PENETRATION

TYPICAL DUCT INSULATION,

SEE MECHANICAL

1" 1"

NOTE: MAINTAIN MINIMUM

5" SEPARATION BETWEEN

PENETRATIONS

SEE WALL TYPES

NOTE: SEE PLANS FOR

WALL TYPE CONSTRUCTION

24" MIN.

PROVIDE OUTLET BOX PAD

APPLIED TO BACK OF BOXES,

TYP

CONTINUOUS BEAD OF

SEALANT AROUND FULL

PERIMETER, TYP.

PLUG ALL UNUSED HOLES

WITH KNOCK-OUT CAPS,

TYP.

FLEXIBLE CONDUIT WITH 6"

SLACK PER 24" RUN

NOTE: SEE PLANS FOR WALL

TYPE CONSTRUCTION

CONTINUOUS BEADS

OF ACOUSTIC

SEALANT AT EDGES

OF GYPSUM BOARD,

MAXIMUM 1/4" GAP

CLEARANCE

TY

P

1/ 4"

M

AX

NOTE: SEE PLANS

FOR WALL TYPE

CONSTRUCTION

1" THICK MINIMUM 1.5 PCF

DENSITY GLASS OR MINERAL

FIBER

PIPE, SEE MECH,

PLUMBING, AND ELEC

1" 1"

1"

D

IA

SEE WALL TYPES

NOTE: SEE PLANS FOR

WALL TYPE CONSTRUCTION

BACKER ROD WITH (2)

CONTINUOUS BEADS OF

ACOUSTIC SEALANT

AROUND FULL PERIMETER

OF PIPE PENETRATION

BACKER ROD WITH (2)

CONTINUOUS BEADS OF

ACOUSTIC SEALANT

AROUND FULL PERIMETER

OF PIPE PENETRATION

SEE WALL TYPES

1/ 2"

M

AX

CONT ACOUSTIC

SEALANT EA SIDE

AGAINST TRACK

CONCRETE SLAB

PER STRUCT

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :04

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A0.05

WALL TYPES & ACOUSTIC

ASSEMBLIES

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 3" = 1'-0"

WALL TYPE 1

SCALE: 3" = 1'-0"

WALL TYPE 2

SCALE: 3" = 1'-0"

WALL TYPE 3

SCALE: 3" = 1'-0"

WALL TYPE 4

SCALE: 3" = 1'-0"

TYP ACOUSTIC WALL DUCT PEN

SCALE: 3" = 1'-0"

TYP ACOUSTIC WALL ELEC BOXES

SCALE: 3" = 1'-0"

TYP ACOUSTIC WALL INTERSECTION

SCALE: 3" = 1'-0"

TYP ACOUSTIC WALL PIPE PEN

SCALE: 3" = 1'-0"

TYP WALL AT FLOOR - ACOUSTIC

UP

UP

UP

DN

DD

DA

D9*

D7

CC

CE

C7

BC

BE

BA

B9*

B7

CA

JROTC

INTRO TO

DIGITAL MEDIA

INTRO TO

ROBOTICS

DEMO 1 / A1.11

DEMO RCP 1 / A1.21

PLAN 1 / A2.11

FINISH 1 / A4.11

RCP 1 / A6.11

DEMO 2 / A1.11

DEMO RCP 2 / A1.21

PLAN 2 / A2.11

FINISH 2 / A4.11

RCP 2 / A6.11

DEMO 3 / A1.11

DEMO RCP 3 / A1.21

PLAN 3 / A2.11

FINISH 3 / A4.11

RCP 3 / A6.11

A6.11 1.5

A6.11 2.5

J1J3

JA

INTRO TO TRADES

DEMO 6 / A1.12

DEMO RCP 6 / A1.22

PLAN 6 / A2.12

FINISH 6 / A4.12

RCP 6 / A6.12

J

D C

B E

LEGEND

NOT IN SCOPE

(E) TO REMAIN

AREA IN SCOPE

IN CEILING, REPLACE (E) RECESSSED LINEAR

FIXTURES, SEE RCPS AND ELECTRICAL DWGS

FLOOR PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

CONDITIONS AND DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL

CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. TYPICAL

DETAILS NOT REFERENCED ON DRAWINGS APPLY UNLESS NOTED

OTHERWISE BY SPECIFIC NOTES AND DETAILS. WHERE NO SPECIFIC

DETAIL IS SHOWN, THE CONSTRUCTION SHALL BE IDENTICAL OR

SIMILAR TO THAT INDICATED FOR THE TYPICAL CONSTRUCTION OF

THE PROJECT.

WHERE NO SPECIFIC STANDARDS ARE APPLIED TO A MATERIAL OR

METHOD OF CONSTRUCTION TO BE USED ON THE WORK, ALL SUCH

MATERIAL AND METHODS ARE TO MAINTAIN STANDARDS OF THE

INDUSTRY AND, WHERE APPLICABLE, MANUFACTURER ’S

INSTRUCTIONS.

LOADING OF CONSTRUCTION MATERIALS SHALL NOT EXCEED THE

DESIGN LIVE LOAD PER SQUARE FOOT.

ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR

ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING WITH

APPROPRIATE TRADES, DRAWINGS, AND SUBCONTRACTORS PRIOR

TO CONSTRUCTION.

PROVIDE ALL NECESSARY ANCHORAGE BLOCKING, BACKING,

FRAMING FOR HANDRAILS, DOOR STOPS, CASEWORK, SHELVING,

MIRRORS, WALL MOUNTED EQUIPMENT, AND ALL OTHER ITEMS AS

REQUIRED FOR COMPLETE INSTALLATION.

CONFIRM ALL ROUGH OPENING DIMENSIONS FOR DOORS AND

WINDOWS PRIOR TO COMMENCEMENT OF CONSTRUCTION.

REVISE AND SUPPLEMENT EXISTING FIRE ALARM AND FIRE

SUPPRESSION SYSTEMS ONLY WHERE NECESSARY TO MEET ALL

APPLICABLE LOCAL AND STATE CODES.

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :06

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A0.11

OVERALL FLOOR PLAN -

LEVEL 1

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/16" = 1'-0" 1OVERALL PLAN - LEVEL 1

SCALE: 1/16" = 1'-0" 2OVERALL PLAN - LEVEL 1 - BUILDING J

NOTE: APPROXIMATE GEOGRAPHIC

LOCATION OF BUILDING J TO MAIN HIGH

SCHOOL BUILDING

DN

DN

DN

DN

DD

DA

D9*

D7

CC

CE

C7

BC

BE

BA

B9*

B7

CA

ONLY WORK ON THIS

LEVEL REPLACEMENT OF

WAYFINDING LETTER AT

WING B, C, D

J1J3

JA

DEMO 7 / A1.12

DEMO RCP 7 / A1.22

PLAN 7 / A2.12

FINISH 7 / A4.12

RCP 7 / A6.12

INTRO TO TRADES:

(E) STORAGE LOFT

REFFER TO MEP SHEETS FOR SCOPE.

J

D C

B E

LEGEND

NOT IN SCOPE

(E) TO REMAIN

AREA IN SCOPE

IN CEILING, REPLACE (E) RECESSSED LINEAR

FIXTURES, SEE RCPS AND ELECTRICAL DWGS

FLOOR PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

CONDITIONS AND DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL

CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. TYPICAL

DETAILS NOT REFERENCED ON DRAWINGS APPLY UNLESS NOTED

OTHERWISE BY SPECIFIC NOTES AND DETAILS. WHERE NO SPECIFIC

DETAIL IS SHOWN, THE CONSTRUCTION SHALL BE IDENTICAL OR

SIMILAR TO THAT INDICATED FOR THE TYPICAL CONSTRUCTION OF

THE PROJECT.

WHERE NO SPECIFIC STANDARDS ARE APPLIED TO A MATERIAL OR

METHOD OF CONSTRUCTION TO BE USED ON THE WORK, ALL SUCH

MATERIAL AND METHODS ARE TO MAINTAIN STANDARDS OF THE

INDUSTRY AND, WHERE APPLICABLE, MANUFACTURER ’S

INSTRUCTIONS.

LOADING OF CONSTRUCTION MATERIALS SHALL NOT EXCEED THE

DESIGN LIVE LOAD PER SQUARE FOOT.

ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR

ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING WITH

APPROPRIATE TRADES, DRAWINGS, AND SUBCONTRACTORS PRIOR

TO CONSTRUCTION.

PROVIDE ALL NECESSARY ANCHORAGE BLOCKING, BACKING,

FRAMING FOR HANDRAILS, DOOR STOPS, CASEWORK, SHELVING,

MIRRORS, WALL MOUNTED EQUIPMENT, AND ALL OTHER ITEMS AS

REQUIRED FOR COMPLETE INSTALLATION.

CONFIRM ALL ROUGH OPENING DIMENSIONS FOR DOORS AND

WINDOWS PRIOR TO COMMENCEMENT OF CONSTRUCTION.

REVISE AND SUPPLEMENT EXISTING FIRE ALARM AND FIRE

SUPPRESSION SYSTEMS ONLY WHERE NECESSARY TO MEET ALL

APPLICABLE LOCAL AND STATE CODES.

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :08

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A0.12

OVERALL FLOOR PLAN -

LEVEL 2

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/16" = 1'-0" 1OVERALL PLAN - LEVEL 2

SCALE: 1/16" = 1'-0" 2OVERALL PLAN - LEVEL 2 - BUILDING J

NOTE: APPROXIMATE GEOGRAPHIC

LOCATION OF BUILDING J TO MAIN HIGH

SCHOOL BUILDING

REF.

DN

R

EF

REF.

DN

J

D C

B E

LEGEND

NOT IN SCOPE

DEMOLITION

(E) TO REMAIN

REMOVE (E) FLOOR FINISH MATERIAL,

ADHESIVE, AND WALL BASE WHERE

APPLICABLE. PREPARE FLOOR FOR

FINISH PER FINISH PLANS

DD

DA

D9* D7

REMOVE SINK

& CASEWORK

REMOVE RELITE

(E) STRUCTURAL

COLUMN TO REMAIN

REMOVE RELITE

REMOVE (E) BANK

OF LOCKERS FROM

EXISTING WALL.

REMOVE WALL MOUNTED

TACK BOARD

REMOVE DOOR

AND FRAME

D 101

D 101C D 101D D 101B

D 101A

REMOVE PORTION OF WALL

FOR RELITE. SEE FLOOR PLAN.

REMOVE (E)

HVAC GRILL

REMOVE (E) MINI BLINDS

ABOVE AND BELOW LIGHT

SHELVES IN WINDOWS.

FIELD VERIFY

LOCATION OF

THRESHOLD.

(E) FLOOR BOXES

TO REMAIN

CC

CE

C7

CA

REMOVE SINK

& CASEWORK

REMOVE (E) BANK

OF LOCKERS.

(E) C101

(E) C101D

(E) C101E A1.11

(E) C101A

(E) C101B

(E) C101C

(E) C101F

REMOVE PAPER

TOWEL DISPENSER

REMOVE AND SALVAGE

INTERIOR LIGHT SHELVES

REMOVE (E)

HVAC GRILL

REMOVE (E) MINI BLINDS

ABOVE AND BELOW LIGHT

SHELVES IN WINDOWS.

(E) FRAME TO REMAIN. REMOVE

DOOR PANEL. SALVAGE DOOR

HARDWARE, LOCKSET, HINGES,

AND KICKPLATE FOR

REINSTALLATION

FIELD VERIFY

LOCATION OF

THRESHOLD.

BC

BE

BA

B9* B7

REMOVE SINK

& CASEWORK

REMOVE RELITE

(E) STRUCTURAL

COLUMN TO REMAIN

REMOVE RELITE

REMOVE (E) BANK

OF LOCKERS.

REMOVE WALL MOUNTED TACK BOARD

B 101 B 101D

B 101E

B 101A

B 101C B 101B

REMOVE PORTION OF WALL

FOR RELITE. SEE FLOOR PLAN.

REMOVE DOOR

AND FRAME

REMOVE DOOR

AND FRAME

REMOVE (E)

HVAC GRILL

REMOVE (E) MINI BLINDS

ABOVE AND BELOW LIGHT

SHELVES IN WINDOWS.

(E) FRAME TO REMAIN. REMOVE DOOR

PANEL. SALVAGE DOOR HARDWARE,

LOCKSET, HINGES, AND KICKPLATE FOR

REINSTALLATION

FIELD VERIFY

LOCATION OF

THRESHOLD.

(E) FLOOR BOXES

TO REMAIN

(E) FLATSCREEN: SALVAGE FOR

REINSTALLATION AT SAME LOCATION,

PROTECT WALL MOUNT

(E) C101E

(E) C101D

(E) C101

REMOVE RELITE

(E) STRUCTURAL

COLUMN TO

REMAIN

REMOVE WALL

MOUNTED TACK BOARD

REMOVE PORTION OF WALL

FOR RELITE. SEE FLOOR PLAN.

REMOVE DOOR

AND FRAME

(E) FRAME TO REMAIN. REMOVE DOOR

PANEL. SALVAGE DOOR HARDWARE,

LOCKSET, HINGES, AND KICKPLATE FOR

REINSTALLATION

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :10

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A1.11

DEMO PLANS

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

DEMO PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

AT DEMOLITION AREA, REMOVE ALL BUILDING ELEMENTS DOWN TO

STRUCTURAL FLOOR AND UP TO STRUCTURAL CEILING, UNLESS

NOTED OTHERWISE. INCLUDING BUT NOT LIMITED TO WALLS,

FINISHES, EQUIPMENT, ELECTRICAL, PLUMBING, AND TECHNOLOGY.

DO NOT DAMAGE OR UNDERMINE FOUNDATIONS SUPPORTING

STRUCTURAL BUILDING ELEMENTS.

PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED TO

SUPPORT REMAINING BUILDING ELEMENTS.

SAW CUT OR OTHERWISE NEATLY REMOVE DEMOLISHED

ELEMENTS AT THE INTERFACE WITH ELEMENTS TO REMAIN.

WHERE ELEMENTS ARE BEING REMOVED, REPAIR AND PATCH

ADJACENT FINISHES. WHERE THIS CREATES CONFLICTS WITH

PATTERN, TEXTURE, OR ALIGNMENT, EXTEND AREA OF REPAIR AND

PATCH TO ELIMINATE CONFLICT.

ALL REPAIR AND PATCH AT FLOOR AREAS MUST ALIGN TO EXISTING

FLOOR LEVEL AND FLOOR THICKNESS.

REVIEW AND DOCUMENT ANY ELEMENTS INTENDED TO REMAIN

WHICH ARE DAMAGED. NOTIFY OWNER AND ARCHITECT PRIOR TO

PROCEEDING WITH WORK IN THAT AREA.

DEMOLISH ABANDONED EQUIPMENT, PIPING, AND CONDUIT AS

NEEDED TO CAP AND TAG EXISTING UTILITIES BEYOND FACE OF

FINISHES.

PROVIDE TEMPORARY DUSTPROOF PARTITIONS TO LIMIT DUST,

DIRT, FUMES, AND NOISE MIGRATION FROM AREAS OF

CONSTRUCTION.

PROTECT IN PLACE EXISTING FLOOR TO REMAIN DURING

CONSTRUCTION.

WHERE PLUMBING FIXTURES, DOORS & DOOR FRAMES,

CASEWORK, ETC ARE INDICATED AS BEING REMOVED AND ARE IN

GOOD CONDITION, SALVAGE ELEMENTS FOR OWNER STOCK.

REFER TO OWNER'S LIST OF SALVAGE ITEMS FOR A COMPLETE LIST

OF ITEMS TO BE SALVAGED PRIOR TO COMMENCEMENT OF

DEMOLITION.

PROTECT EXISTING FLOOR RECEPTICLES WHERE APPLICABLE.

SCALE: 1/8" = 1'-0" 3DEMO - L1 - JROTC

SCALE: 1/8" = 1'-0" 2DEMO - L1 - INTRO TO DIGITAL MEDIA

SCALE: 1/8" = 1'-0" 1DEMO - L1 - INTRO TO ROBOTICS

SCALE: 1/4" = 1'-0" 4INTRO TO DIGITAL MEDIA - ENLARGED PLAN

J

D C

B E

J1J3

JA

(E) COLUMN TO REMAIN

PROTECT (E)

STAIR & RAILING

REMOVE FOLDING

WALL AND TRACK

REMOVE WHITE BOARD

J111

J110

J107

(E) IDF CABINET

TO REMAIN

REMOVE DOOR

AND FRAME

REMOVE (E) MINI BLINDS

REMOVE (E)

MINI BLINDS

REMOVE (3) UPPER CABS

(E) CMU WALL

TO REMAIN

LEGEND

NOT IN SCOPE

DEMOLITION

(E) TO REMAIN

REMOVE (E) FLOOR FINISH MATERIAL,

ADHESIVE, AND WALL BASE WHERE

APPLICABLE. PREPARE FLOOR FOR

FINISH PER FINISH PLANS

J1J3

JA

OPEN TO

BELOW

J201

REFFER TO MEP SHEETS FOR SCOPE.

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :11

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A1.12

DEMO PLANS

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/8" = 1'-0" 1DEMO - L1 - INTRO TO TRADES

DEMO PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

AT DEMOLITION AREA, REMOVE ALL BUILDING ELEMENTS DOWN TO

STRUCTURAL FLOOR AND UP TO STRUCTURAL CEILING, UNLESS

NOTED OTHERWISE. INCLUDING BUT NOT LIMITED TO WALLS,

FINISHES, EQUIPMENT, ELECTRICAL, PLUMBING, AND TECHNOLOGY.

DO NOT DAMAGE OR UNDERMINE FOUNDATIONS SUPPORTING

STRUCTURAL BUILDING ELEMENTS.

PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED TO

SUPPORT REMAINING BUILDING ELEMENTS.

SAW CUT OR OTHERWISE NEATLY REMOVE DEMOLISHED

ELEMENTS AT THE INTERFACE WITH ELEMENTS TO REMAIN.

WHERE ELEMENTS ARE BEING REMOVED, REPAIR AND PATCH

ADJACENT FINISHES. WHERE THIS CREATES CONFLICTS WITH

PATTERN, TEXTURE, OR ALIGNMENT, EXTEND AREA OF REPAIR AND

PATCH TO ELIMINATE CONFLICT.

ALL REPAIR AND PATCH AT FLOOR AREAS MUST ALIGN TO EXISTING

FLOOR LEVEL AND FLOOR THICKNESS.

REVIEW AND DOCUMENT ANY ELEMENTS INTENDED TO REMAIN

WHICH ARE DAMAGED. NOTIFY OWNER AND ARCHITECT PRIOR TO

PROCEEDING WITH WORK IN THAT AREA.

DEMOLISH ABANDONED EQUIPMENT, PIPING, AND CONDUIT AS

NEEDED TO CAP AND TAG EXISTING UTILITIES BEYOND FACE OF

FINISHES.

PROVIDE TEMPORARY DUSTPROOF PARTITIONS TO LIMIT DUST,

DIRT, FUMES, AND NOISE MIGRATION FROM AREAS OF

CONSTRUCTION.

PROTECT IN PLACE EXISTING FLOOR TO REMAIN DURING

CONSTRUCTION.

WHERE PLUMBING FIXTURES, DOORS & DOOR FRAMES,

CASEWORK, ETC ARE INDICATED AS BEING REMOVED AND ARE IN

GOOD CONDITION, SALVAGE ELEMENTS FOR OWNER STOCK.

REFER TO OWNER'S LIST OF SALVAGE ITEMS FOR A COMPLETE LIST

OF ITEMS TO BE SALVAGED PRIOR TO COMMENCEMENT OF

DEMOLITION.

PROTECT EXISTING FLOOR RECEPTICLES WHERE APPLICABLE.

SCALE: 1/8" = 1'-0" 2DEMO - L2 - INTRO TO TRADES

C

B E

CC

CE

C7

CA

REMOVE FIXTURES

IN (E) CEILING

A1.21

(E) C101

(E) C101D

(E) C101E

(E) C101A

(E) C101B

(E) C101C

(E) C101F

BC

BE

BA

B9* B7

REMOVE FIXTURES

IN (E) CEILING

B 101B 101D

B 101E

B 101A

B 101CB 101B

A9.12

DA

D9* D7

REMOVE FIXTURES

IN (E) CEILING

D 101

D 101C D 101DD 101B

D 101A

(E) C101E

(E) C101D

(E) C101

LEGEND

DEMOLITION AREA: REMOVE GYP. BD.

CEILING, LIGHT FIXTURES AND CEILING

MOUNTED EQUIPMENT. SEE

MECHANICAL, PLUMBING AND

ELECTRICAL DRAWINGS.

NOT IN SCOPE

DEMOLITION

(E) TO REMAIN

BE

B9*

REMOVE (E) FIXTURE,

PREPARE OPENING FOR

REPLACEMENT. SEE

ELECTRICAL.

/1 A1.21

/2 A1.21

CE

REMOVE (E) FIXTURE,

PREPARE OPENING FOR

REPLACEMENT. SEE

ELECTRICAL.

/3 A1.21

/2 A1.21

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :12

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A1.21

DEMO REFLECTED

CEILING PLANS

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/8" = 1'-0" 2DEMO RCP - L1 - INTRO TO DIGITAL MEDIA

SCALE: 1/8" = 1'-0" 1DEMO RCP - L1 - INTRO TO ROBOTICS

SCALE: 1/8" = 1'-0" 3DEMO RCP - L1 - JROTC

SCALE: 1/4" = 1'-0" 4INTRO TO DIGITAL MEDIA - ENLARGED PLAN

DEMO PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

AT DEMOLITION AREA, REMOVE ALL BUILDING ELEMENTS DOWN TO

STRUCTURAL FLOOR AND UP TO STRUCTURAL CEILING, UNLESS

NOTED OTHERWISE. INCLUDING BUT NOT LIMITED TO WALLS,

FINISHES, EQUIPMENT, ELECTRICAL, PLUMBING, AND TECHNOLOGY.

DO NOT DAMAGE OR UNDERMINE FOUNDATIONS SUPPORTING

STRUCTURAL BUILDING ELEMENTS.

PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED TO

SUPPORT REMAINING BUILDING ELEMENTS.

SAW CUT OR OTHERWISE NEATLY REMOVE DEMOLISHED

ELEMENTS AT THE INTERFACE WITH ELEMENTS TO REMAIN.

WHERE ELEMENTS ARE BEING REMOVED, REPAIR AND PATCH

ADJACENT FINISHES. WHERE THIS CREATES CONFLICTS WITH

PATTERN, TEXTURE, OR ALIGNMENT, EXTEND AREA OF REPAIR AND

PATCH TO ELIMINATE CONFLICT.

ALL REPAIR AND PATCH AT FLOOR AREAS MUST ALIGN TO EXISTING

FLOOR LEVEL AND FLOOR THICKNESS.

REVIEW AND DOCUMENT ANY ELEMENTS INTENDED TO REMAIN

WHICH ARE DAMAGED. NOTIFY OWNER AND ARCHITECT PRIOR TO

PROCEEDING WITH WORK IN THAT AREA.

DEMOLISH ABANDONED EQUIPMENT, PIPING, AND CONDUIT AS

NEEDED TO CAP AND TAG EXISTING UTILITIES BEYOND FACE OF

FINISHES.

PROVIDE TEMPORARY DUSTPROOF PARTITIONS TO LIMIT DUST,

DIRT, FUMES, AND NOISE MIGRATION FROM AREAS OF

CONSTRUCTION.

PROTECT IN PLACE EXISTING FLOOR TO REMAIN DURING

CONSTRUCTION.

WHERE PLUMBING FIXTURES, DOORS & DOOR FRAMES,

CASEWORK, ETC ARE INDICATED AS BEING REMOVED AND ARE IN

GOOD CONDITION, SALVAGE ELEMENTS FOR OWNER STOCK.

REFER TO OWNER'S LIST OF SALVAGE ITEMS FOR A COMPLETE LIST

OF ITEMS TO BE SALVAGED PRIOR TO COMMENCEMENT OF

DEMOLITION.

PROTECT EXISTING FLOOR RECEPTICLES WHERE APPLICABLE.

SCALE: 1/8" = 1'-0" 1.5DEMO RCP- L1 - C TO B

SCALE: 1/8" = 1'-0" 2.5RCP - L1 - D TO C

C

B E

LEGEND

NOT IN SCOPE

DEMOLITION

(E) TO REMAIN

REMOVE (E) FLOOR FINISH MATERIAL,

ADHESIVE, AND WALL BASE WHERE

APPLICABLE. PREPARE FLOOR FOR

FINISH PER FINISH PLANS

J1J3

JA

OPEN TO

ABOVEJ111

J110

J107

J1J3

JA

J201

REFFER TO MEP SHEETS FOR SCOPE.

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :13

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A1.22

DEMO REFLECTED

CEILING PLANS

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

DEMO PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

AT DEMOLITION AREA, REMOVE ALL BUILDING ELEMENTS DOWN TO

STRUCTURAL FLOOR AND UP TO STRUCTURAL CEILING, UNLESS

NOTED OTHERWISE. INCLUDING BUT NOT LIMITED TO WALLS,

FINISHES, EQUIPMENT, ELECTRICAL, PLUMBING, AND TECHNOLOGY.

DO NOT DAMAGE OR UNDERMINE FOUNDATIONS SUPPORTING

STRUCTURAL BUILDING ELEMENTS.

PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED TO

SUPPORT REMAINING BUILDING ELEMENTS.

SAW CUT OR OTHERWISE NEATLY REMOVE DEMOLISHED

ELEMENTS AT THE INTERFACE WITH ELEMENTS TO REMAIN.

WHERE ELEMENTS ARE BEING REMOVED, REPAIR AND PATCH

ADJACENT FINISHES. WHERE THIS CREATES CONFLICTS WITH

PATTERN, TEXTURE, OR ALIGNMENT, EXTEND AREA OF REPAIR AND

PATCH TO ELIMINATE CONFLICT.

ALL REPAIR AND PATCH AT FLOOR AREAS MUST ALIGN TO EXISTING

FLOOR LEVEL AND FLOOR THICKNESS.

REVIEW AND DOCUMENT ANY ELEMENTS INTENDED TO REMAIN

WHICH ARE DAMAGED. NOTIFY OWNER AND ARCHITECT PRIOR TO

PROCEEDING WITH WORK IN THAT AREA.

DEMOLISH ABANDONED EQUIPMENT, PIPING, AND CONDUIT AS

NEEDED TO CAP AND TAG EXISTING UTILITIES BEYOND FACE OF

FINISHES.

PROVIDE TEMPORARY DUSTPROOF PARTITIONS TO LIMIT DUST,

DIRT, FUMES, AND NOISE MIGRATION FROM AREAS OF

CONSTRUCTION.

PROTECT IN PLACE EXISTING FLOOR TO REMAIN DURING

CONSTRUCTION.

WHERE PLUMBING FIXTURES, DOORS & DOOR FRAMES,

CASEWORK, ETC ARE INDICATED AS BEING REMOVED AND ARE IN

GOOD CONDITION, SALVAGE ELEMENTS FOR OWNER STOCK.

REFER TO OWNER'S LIST OF SALVAGE ITEMS FOR A COMPLETE LIST

OF ITEMS TO BE SALVAGED PRIOR TO COMMENCEMENT OF

DEMOLITION.

PROTECT EXISTING FLOOR RECEPTICLES WHERE APPLICABLE.

SCALE: 1/8" = 1'-0" 1DEMO RCP - L1 - INTRO TO TRADES

SCALE: 1/8" = 1'-0" 2DEMO RCP - L2 - INTRO TO TRADES

DN

A1 WALL TAG

FLOOR PLAN NOTES:

1.

2.

3.

4.

5.

6.

CONDITIONS AND DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL

CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. TYPICAL

DETAILS NOT REFERENCED ON DRAWINGS APPLY UNLESS NOTED

OTHERWISE BY SPECIFIC NOTES AND DETAILS. WHERE NO SPECIFIC

DETAIL IS SHOWN, THE CONSTRUCTION SHALL BE IDENTICAL OR

SIMILAR TO THAT INDICATED FOR THE TYPICAL CONSTRUCTION OF

THE PROJECT.

WHERE A LENGTH OF WALL IS INTERSECTED BY PERPENDICULAR

WALLS, WALL TYPE TO BE CONTINUOUS BETWEEN TAGS UNLESS

NOTED OTHERWISE.

PROVIDE SOLID BLOCKING BETWEEN ROOF JOISTS WHERE WALL

RUNS PERPENDICULAR TO ROOF JOISTS. GYPSUM BOARD TO

TERMINATE AT ROOF JOISTS.

ALIGN FINISHES WHERE INDICATED.

DOORS NOT LOCATED BY DIMENSION ARE TO BE CENTERED IN

WALLS AS SHOWN OR LOCATED 6" FROM FACE OF STUD TO FACE OF

JAMB.

DIMENSIONS ARE TO FACES OF STUD UNLESS NOTED OTHERWISE.

LEGEND

BC

BE

BA

B9* B7

(E) ELEC RM

B101D

(E) RR

B101B

STOR

B101C

(E) MECH

B101A

A5.20

1A

A5.202D

2A

2B

2C

A5.01 1B

A5.01

1C

A5.20 1B

1C

1D

A5.201E

A5.011D

B101a

A5.203D

(E) FIRE EXTINGUISHER.

W/ IN 75' OF (N) ROOM

2a

B1

.3

B1

.1

INTRO TO

ROBOTICS

B101

CL 4' - 4" FOF

SPINE DISPLAY CASE

FLAT PANEL MONITOR (OFCI)

USE EXISTING DOOR

OPENING FOR (N) DOOR

A9.12

(4) (E) FLOOR

BOXES

A9.11

CC

CE

C7

CA

STOR

C101G

(E) RR

C101C

CONTROL

RM

C101D

PRODUCTION

STUDIO

C101

(E) MECH

C101A

(E) OFC

C101B

(E) ELEC RM

C101F

A5.30 1B

1C

A5.301D

A5.01 2B

A5.01

2C

HALL

C101H

A5.30

1A

3a* A2.11

2A

A5.203D

(E) FIRE EXTINGUISHER.

W/ IN 75' OF (N) ROOM

PODCASTING/

RECORDING

C101E

SPINE DISPLAY CASE

FLAT PANEL MONITOR (OFCI)

A9.30

SIM

A9.11

DD

DA

D9* D7

STORAGE

D101D

OFFICE

D101C

JROTC

DRILL RM

D101

(E) MECH

D101A

(E) RR

D101B

A5.40

1C

A5.40

5A

5B

5C

5D

A5.40

3E

A5.01

3C

A5.01 3B

1B

A5.40

3C

A5.401D

A5.013D

A5.40

1A

A5.403D

3A

3B

ARMOR

ROOM

D101E

1a

1a

D

1.

1a1a

D101.2

D101.4

D

1.

D101a

D

1b

D101c

A5.203D

HALL

D101F

A5.40 4B

4C

SPINE DISPLAY CASE

FLAT PANEL MONITOR (OFCI)

6'-0"

5' -6

5'

-0

3'-9" 11'-2"

2' -0

4'

-5

'-5

(4) (E) FLOOR BOXES

A9.20

A9.11

J

D C

B E

A5.30

A5.303D

3A

2B

2A

A5.012DA5.30 3BA5.30

3C

A5.302D A5.30

2C

A5.30

6C

A5.30 4B A5.305D A5.30

5A

5B

5C

6A

A5.306D 6B

CONTROL

RM

C101D

STOR

C101G

PODCASTING/

RECORDING

C101E C101.4

C

1.

C

1.

C

1.

C101b

C101a

PRODUCTION

STUDIO

C101

C101.2

(E) PAINTED

COLUMN TO

REMAIN

2a

2a

3a*

1a

3a*

3a*

7' -7

/4

9' -8

/4

A9.30

21EQ

EQ

6'-0"

USE EXISTING DOOR

OPENING FOR (N) DOOR

7'-8" MIN CLR, VIF

21'-10"

6'-6" 6'-1" 13'-9" 2'-0"

12" MIN CLR

5' -2

2'

-6

C

1.

A5.30

4C

HALL

C101H

A9.30

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :15

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A2.11

FLOOR PLANS

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/8" = 1'-0" 1FLOOR PLAN - L1 - INTRO TO ROBOTICS

SCALE: 1/8" = 1'-0" 2FLOOR PLAN - L1 - INTRO TO DIGITAL MEDIA

SCALE: 1/8" = 1'-0" 3FLOOR PLAN - L1 - JROTC

SCALE: 1/4" = 1'-0" 2AINTRO TO DIGITAL MEDIA - ENLARGED PLAN

A1 WALL TAG

FLOOR PLAN NOTES:

1.

2.

3.

4.

5.

6.

CONDITIONS AND DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL

CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. TYPICAL

DETAILS NOT REFERENCED ON DRAWINGS APPLY UNLESS NOTED

OTHERWISE BY SPECIFIC NOTES AND DETAILS. WHERE NO SPECIFIC

DETAIL IS SHOWN, THE CONSTRUCTION SHALL BE IDENTICAL OR

SIMILAR TO THAT INDICATED FOR THE TYPICAL CONSTRUCTION OF

THE PROJECT.

WHERE A LENGTH OF WALL IS INTERSECTED BY PERPENDICULAR

WALLS, WALL TYPE TO BE CONTINUOUS BETWEEN TAGS UNLESS

NOTED OTHERWISE.

PROVIDE SOLID BLOCKING BETWEEN ROOF JOISTS WHERE WALL

RUNS PERPENDICULAR TO ROOF JOISTS. GYPSUM BOARD TO

TERMINATE AT ROOF JOISTS.

ALIGN FINISHES WHERE INDICATED.

DOORS NOT LOCATED BY DIMENSION ARE TO BE CENTERED IN

WALLS AS SHOWN OR LOCATED 6" FROM FACE OF STUD TO FACE OF

JAMB.

DIMENSIONS ARE TO FACES OF STUD UNLESS NOTED OTHERWISE.

LEGEND

J

D C

B E

J1J3

JA

INTRO TO

TRADES CR

J111

(E)

IDF

A5.90

1C

1B

1A

1D

3a

A9.10

TOTAL

OF (2)(4

) 4 ' x

' B

O O

TH

S

(M

ET

AL

(6) 4' x 4' BOOTHS (WOOD)

'-8

6'-2"

TRADE BOOTHS,

SEE STRUCTURAL

2'-9" 3'-10"

1'-3" MIN CLR

FIRESTOPPING AT PIPE

PEN THROUGH (E) 1-HR

WALL, SEE PLUMBING

EYEWASH, SEE PLUMBING

LINE OF (E)

MEZZANINE ABOVE

J1J3

JA

OPEN TO

BELOW

(E) STOR

LOFT

J201

A5.90 2B

2A

2D

2C

REFFER TO MEP SHEETS FOR SCOPE.

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :16

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A2.12

FLOOR PLANS

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/8" = 1'-0" 1FLOOR PLAN - L1 - INTRO TO TRADES

SCALE: 1/8" = 1'-0" 2FLOOR PLAN - L2 - INTRO TO TRADES

DN

LEGEND:

BASE DESIGNATIONS:

B-1 4" RUBBER BASE

CORNER GUARDS:

NOTE: ALL CORNER GUARDS ARE STAINLESS STEEL 'L' SHAPED WITH

2" LEGS; HEIGHT INDICATED IS LENGTH OF CORNER GUARD

CG-1 6'-4" : ALIGN TOPS TO ADJACENT TACK SURFACE

CG-2 6'-10" : ALIGN TOPS TO ADJACENT DOOR FRAMES

FLOOR DRAIN - SEE PLUMBING

FLOOR BOX - SEE ELECTRICAL

AND TECHNOLOGY

CPT-1

CARPET TILE

SHEET NOTES:

1.

2.

3.

4.

5.

6.

7.

SEE FINISH LEGEND FOR MATERIAL DESIGNATIONS.

EXTEND FLOOR FINISHES UNDER TOEKICKS, OPEN COUNTERTOPS

AND EQUIPMENT, TYPICAL. EXTEND SCHEDULED BASE BEHIND ALL

APPLIANCES, TYPICAL.

ALL CLOSET FINISHES SHALL MATCH THE ADJACENT ROOM UNLESS

SPECIFICALLY NOTED OTHERWISE.

PROVIDE SPECIFIED TRANSITION STRIPS WHERE UNLIKE MATERIALS

MEET UNLESS NOTED OTHERWISE.

WHERE FLOOR FINISH CHANGES MATERIAL, COLOR, OR PATTERN AT

A DOOR, LOCATION SPECIFIED TRANSITION UNDER CENTERLINE OF

DOOR UNLESS NOTED OTHERWISE.

SEE VERTICAL CIRCULATION SHEET(S) FOR INFORMATION ON STAIR

AND/OR RAMP FINISHES.

JOINTS IN EXPOSED CONCRETE, FLOOR DRAINS, FLOOR

DATA/OUTLET, AND OTHER ELEMENTS RECESSED IN THE FLOOR ARE

SHOWN FOR REFERENCE ONLY. SEE SLAB PLANS.

LIN-1

SHEET

LINOLEUM

POL-1

POLISHED

CONCRETE

DD

DA

D9* D7

JROTC

DRILL

RM

D101

POL-1

B-1

STORAGE

D101D

POL-1

B-1

ARMOR

ROOM

D101E

POL-1

B-1

OFFICE

D101C

CPT-1

B-1

HALL

D101F

CPT-1

B-1

CG - 1

(E)

RR

D101B (E) (E)

JROTC EQUIPMENT STORAGE RACK (OFCI)

(E) EQUIPMENT

STORAGE RACK,

OFCI

A9.11

A9.20

A9.20

A9.20

(E) FLOOR

RECEPTACLES (TOTAL

OF 4) - REPLACE FLOOR

BOX COVERS WITH S/S

COVERS

CC

CE

C7

CA

PRODUCTION

STUDIO

C101

LIN-1

B-1

HALL

C101H

CPT-1

B-1

STOR

C101G

LIN-1

B-1

PODCASTING/

RECORDING

C101E

CPT-1

B-1

CONTROL

RM

C101D

CPT-1

B-1

A4.11

(E)

RR

C101C (E) (E)

A9.20

LIN-1

CG-2

BC

BE

BA

B9* B7

STOR

B101C

POL-1

B-1

(E)

ELEC

RM

B101D (E) (E)

CG - 1

(E)

RR

B101B (E) (E)

(E) FLOOR

RECEPTACLES

(TOTAL OF 4) -

REPLACE FLOOR

BOX COVERS

WITH S/S

COVERS

HALL

B101E

CPT-1

B-1

INTRO

TO

ROBOTICS

B101

POL-1

B-1

A9.12

5' X 5' CONC. POLISH

IN-PLACE MOCKUP

A9.20

J

D C

B E

CONTROL

RM

C101D

CPT-1

B-1

PODCASTING/

RECORDING

C101E

CPT-1

B-1

STOR

C101G

LIN-1

B-1

PRODUCTION

STUDIO

C101

LIN-1

B-1

HALL

C101H

CPT-1

B-1

CG - 1

LIN-1

A9.20

A9.20

CG-2

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :18

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A4.11

FINISH FLOOR PLANS

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/8" = 1'-0" 3FINISH FLOOR PLAN - L1 - JROTC

SCALE: 1/8" = 1'-0" 2FINISH FLOOR PLAN - L1 - INTRO TO DIGITAL MEDIA

SCALE: 1/8" = 1'-0" 1FINISH FLOOR PLAN - L1 - INTRO TO ROBOTICS

SCALE: 1/4" = 1'-0" 4INTRO TO DIGITL MEDIA - ENLARGED PLAN

OPEN TO

BELOW

LEGEND:

BASE DESIGNATIONS:

B-1 4" RUBBER BASE

CORNER GUARDS:

NOTE: ALL CORNER GUARDS ARE STAINLESS STEEL 'L' SHAPED WITH

2" LEGS; HEIGHT INDICATED IS LENGTH OF CORNER GUARD

CG-1 6'-4" : ALIGN TOPS TO ADJACENT TACK SURFACE

CG-2 6'-10" : ALIGN TOPS TO ADJACENT DOOR FRAMES

FLOOR DRAIN - SEE PLUMBING

FLOOR BOX - SEE ELECTRICAL

AND TECHNOLOGY

CPT-1

CARPET TILE

SHEET NOTES:

1.

2.

3.

4.

5.

6.

7.

SEE FINISH LEGEND FOR MATERIAL DESIGNATIONS.

EXTEND FLOOR FINISHES UNDER TOEKICKS, OPEN COUNTERTOPS

AND EQUIPMENT, TYPICAL. EXTEND SCHEDULED BASE BEHIND ALL

APPLIANCES, TYPICAL.

ALL CLOSET FINISHES SHALL MATCH THE ADJACENT ROOM UNLESS

SPECIFICALLY NOTED OTHERWISE.

PROVIDE SPECIFIED TRANSITION STRIPS WHERE UNLIKE MATERIALS

MEET UNLESS NOTED OTHERWISE.

WHERE FLOOR FINISH CHANGES MATERIAL, COLOR, OR PATTERN AT

A DOOR, LOCATION SPECIFIED TRANSITION UNDER CENTERLINE OF

DOOR UNLESS NOTED OTHERWISE.

SEE VERTICAL CIRCULATION SHEET(S) FOR INFORMATION ON STAIR

AND/OR RAMP FINISHES.

JOINTS IN EXPOSED CONCRETE, FLOOR DRAINS, FLOOR

DATA/OUTLET, AND OTHER ELEMENTS RECESSED IN THE FLOOR ARE

SHOWN FOR REFERENCE ONLY. SEE SLAB PLANS.

LIN-1

SHEET

LINOLEUM

POL-1

POLISHED

CONCRETE

J1J3

JA

INTRO

TO

TRADES

CR

J111 (E) (E)

WHERE WALL REMOVED, FINISH

FLOOR TO MATCH (E) ADJACENT

J

D C

B E

J1J3

JA

(E)

STOR

LOFT

J201 (E) (E)

REFFER TO MEP SHEETS FOR SCOPE.

(E) CASEWORK AND

STORAGE UNITS

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :18

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A4.12

FINISH FLOOR PLANS

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/8" = 1'-0" 1FINISH FLOOR PLAN - L1 - INTRO TO TRADES

SCALE: 1/8" = 1'-0" 2FINISH FLOOR PLAN - L2 - INTRO TO TRADES

P-1

A9.11

P-1 PAINT STEPPED SOFFIT AND FASCIA FULL LOCKER WALL LENGTH

P-1

P-1P-1 D

TS-2 TS-2

RUBBER BASE, TYP

TS

-2

8'-0"

EQEQFILL

A9.11

CORNER GUARD

A9.30

P-1

TS-2 TS-2

EQEQ

6' -4

6"

4"

P-1 P-1 P-1

C

EQEQ

8'-0"

RUBBER BASE, TYP

FILL

A9.11

TS-2TS-2TS-2

CORNER GUARD

A9.30

ON AIR

8' -0

CLP-1

TS-2 TS-2

EQEQ

6' -4

6"

4"

P-1

A9.11

P-1 PAINT STEPPED SOFFIT AND FASCIA FULL LOCKER WALL LENGTH

J

D C

B E

SHEET NOTES:LEGEND:MOUNTING HEIGHTS:

P-X

CONTROL JOINTCJ

TACKBOARDTB-X

PAINT COLOR (P-X)

PLASTIC LAMINATE (PL-X)

OWNER FURNISHED,

OWNER INSTALLEDOFOI

OWNER FURNISHED,

CONTRACTOR INSTALLEDOFCI

CASEWORK TYPEXX#X

WS1 ROLLER SHADES -

MANUAL

WS2 BLACKOUT SHADES -

MANUAL

FIRE EXTINGUISHER CABINETFEC-X

FEC-B

PL-X

WINDOW COVERINGS:

WCT-X FINISH MATERIAL PER

FINISH LEGEND

TS-2

TS-1

AWP-2

AWP-1

TACKSURFACE

TACKSURFACE

CUSTOM GRAPHIC

ACOUSTIC WALL

PANEL

TACKABLE

ACOUSTIC WALL

PANEL

FIBER

REINFORCED

PANEL

FRP-1

1.

2.

3.

4.

5.

6.

7.

MATERIALS WHICH ARE IN SIMILAR LOCATIONS ARE NOT NOTED AT EVERY

OCCURRENCE.

SEE FINISH FLOOR PLANS, REFLECTED CEILING PLANS, INTERIOR ELEVATIONS

AND FINISH LEGEND FOR ADDITIONAL INFORMATION.

SEE DOOR AND FRAME TYPES FOR ADDITIONAL INFORMATION AND REFERENCE

TO DETAILS.

DOOR SWINGS SHOWN ON ELEVATIONS ARE FOR REFERENCE ONLY- SEE FLOOR

PLANS.

ALL WALLS NOT ELEVATED OR TAGGED TO BE PAINTED P-1 (UNLESS NOTED

OTHERWISE).

MECHANICAL GRILLES AND ACCESS PANELS IN WALLS SHALL MATCH THE COLOR

OF THE WALL WHERE LOCATED, UNLESS NOTED OTHERWISE.

PROVIDE SOLID 2X BLOCKING AT ALL WALL MOUNTED ITEMS.

8. ALL COUNTERS TO BE PL-1, UNLESS NOTED OTHERWISE.

9. ALL CABINETS TO BE PL-2, UNLESS NOTED OTHERWISE.

10. SEE FINISH FLOOR PLANS FOR WALL BASE DESIGNATIONS.

11. ALL NEW WALLS TO HAVE IMPACT RESISTANT GYPSUM BOARD UP TO 4'-0" AFF.

1.

2.

HEIGHTS TYPICAL, UNLESS NOTED OTHERWISE.

PROVIDE BLOCKING PER SHEET NOTES AND PROJECT MANUAL.

WHERE BLOCKING IS SHOWN, PROVIDE BLOCKING AS INDICATED.

4'

8" R

.O

3' -1

0"

8' -0

5' -0

SIGNAGE, SEE

SIGNAGE SCHEDULE

SPEAKER

PULL

STATION

MARKER

BOARDTACKBOARD

7' -2

EQ EQ

FLAT PANEL MONITOR (OFCI)

BLOCKING PER MOUNTING

BRACKET REQUIRMENTS

8' -2

CLOCK (OFOI)

POWER/DATA PER ELEC & TECH, SEE

ELEC & TECH FOR HEIGHTS, VERIFY

WITH MANUFACTURER

FLAT PANEL MONITOR (OFCI) &

MOUNTING BRACKET (OFCI)

CUSTOM VINYL

GRAPHIC ON

GLAZING, APPLY ON

NON-CORRIDOR SIDE,

SEAL EDGES

LABORATORY GRADE

COMPACT LAMINATE (CPL-X)

CPL-X

TS-2

P-1P-1P-1

TS-2

BEQEQ

RUBBER BASE, TYP

8'-0"

TS

-2

A9.11

CORNER GUARD

A9.30

FILL

(E) FLATSCREEN

P-1

A9.11

P-1 PAINT STEPPED SOFFIT AND FASCIA FULL LOCKER WALL LENGTH

P-1

TS-2 TS-2

EQEQ

6' -4

6"

4"

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :20

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A5.01

INTERIOR ELEVATIONS -

HALLWAYS

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/4" = 1'-0"

3B

ACADEMIC WING D - MAIN SPINE & ACADEMIC WING HALL

3C3D

2C2D

SCALE: 1/4" = 1'-0"

2B

ACADEMIC WING C - MAIN SPINE & ACADEMIC WING HALL

1C

SCALE: 1/4" = 1'-0"

1B

ACADEMIC WING B - MAIN SPINE & ACADEMIC WING HALL

1D

OPEN OPEN OPEN OPEN

TS-1

P-1P-1P-1

DISPLAY CASE

EQ EQ

EQ EQ

TS-1

FLAT PANEL MONITOR. SEE MOUNTING HEIGHT NOTE.P-1

6' -1

0" 4"

4X8 MB4'x4' TB-1 4X8 MB

P-1 P-1

EQ EQ EQ EQ

WS1 WS1 WS1

CPL-1 COUNTERTOP W/ 4" BACKSPLASH FULL LENGTH OF WALL32"W x 23"D x34" H

(TOTAL OF 6)

A9.10

96"x48" STEEL PEGBOARD

48"x48" STEEL PEGBOARD

WS1 WS1 WS1

P-1EQEQ

MC-2 CABINETS (TOTAL OF 5)

48"x48" STEEL PEGBOARD

P-1 DISPLAY CASE

CPL-1 COUNTERTOP

A9.10

32"W x 23" D x 34" H

32"W x 23" D x 34" H

P-1P-1P-1

WS2

A9.12

WS2

PATCH AND REPAIR WALL AS

NEEDED WHERE CASEWORK

AND PLUMBING REMOVED

WINDOW DISPLAY SHELVING

P-1 P-1 P-1

TS-1TS-1 TS-1

12'-0"

6' -1

0" 4"

EQ EQ EQ

P-1

SHEET NOTES:LEGEND:MOUNTING HEIGHTS:

P-X

CONTROL JOINTCJ

TACKBOARDTB-X

PAINT COLOR (P-X)

PLASTIC LAMINATE (PL-X)

OWNER FURNISHED,

OWNER INSTALLEDOFOI

OWNER FURNISHED,

CONTRACTOR INSTALLEDOFCI

CASEWORK TYPEXX#X

WS1 ROLLER SHADES -

MANUAL

WS2 BLACKOUT SHADES -

MANUAL

FIRE EXTINGUISHER CABINETFEC-X

FEC-B

PL-X

WINDOW COVERINGS:

WCT-X FINISH MATERIAL PER

FINISH LEGEND

TS-2

TS-1

AWP-2

AWP-1

TACKSURFACE

TACKSURFACE

CUSTOM GRAPHIC

ACOUSTIC WALL

PANEL

TACKABLE

ACOUSTIC WALL

PANEL

FIBER

REINFORCED

PANEL

FRP-1

1.

2.

3.

4.

5.

6.

7.

MATERIALS WHICH ARE IN SIMILAR LOCATIONS ARE NOT NOTED AT EVERY

OCCURRENCE.

SEE FINISH FLOOR PLANS, REFLECTED CEILING PLANS, INTERIOR ELEVATIONS

AND FINISH LEGEND FOR ADDITIONAL INFORMATION.

SEE DOOR AND FRAME TYPES FOR ADDITIONAL INFORMATION AND REFERENCE

TO DETAILS.

DOOR SWINGS SHOWN ON ELEVATIONS ARE FOR REFERENCE ONLY- SEE FLOOR

PLANS.

ALL WALLS NOT ELEVATED OR TAGGED TO BE PAINTED P-1 (UNLESS NOTED

OTHERWISE).

MECHANICAL GRILLES AND ACCESS PANELS IN WALLS SHALL MATCH THE COLOR

OF THE WALL WHERE LOCATED, UNLESS NOTED OTHERWISE.

PROVIDE SOLID 2X BLOCKING AT ALL WALL MOUNTED ITEMS.

8. ALL COUNTERS TO BE PL-1, UNLESS NOTED OTHERWISE.

9. ALL CABINETS TO BE PL-2, UNLESS NOTED OTHERWISE.

10. SEE FINISH FLOOR PLANS FOR WALL BASE DESIGNATIONS.

11. ALL NEW WALLS TO HAVE IMPACT RESISTANT GYPSUM BOARD UP TO 4'-0" AFF.

1.

2.

HEIGHTS TYPICAL, UNLESS NOTED OTHERWISE.

PROVIDE BLOCKING PER SHEET NOTES AND PROJECT MANUAL.

WHERE BLOCKING IS SHOWN, PROVIDE BLOCKING AS INDICATED.

4'

8" R

.O

3' -1

0"

8' -0

5' -0

SIGNAGE, SEE

SIGNAGE SCHEDULE

SPEAKER

PULL

STATION

MARKER

BOARDTACKBOARD

7' -2

EQ EQ

FLAT PANEL MONITOR (OFCI)

BLOCKING PER MOUNTING

BRACKET REQUIRMENTS

8' -2

CLOCK (OFOI)

POWER/DATA PER ELEC & TECH, SEE

ELEC & TECH FOR HEIGHTS, VERIFY

WITH MANUFACTURER

FLAT PANEL MONITOR (OFCI) &

MOUNTING BRACKET (OFCI)

CUSTOM VINYL

GRAPHIC ON

GLAZING, APPLY ON

NON-CORRIDOR SIDE,

SEAL EDGES

LABORATORY GRADE

COMPACT LAMINATE (CPL-X)

CPL-X

" M

IN

3'

-4

3'-5"

(N) VERTICAL GRAB BAR, 1.5"

DIA. STAINLESS STEEL, FINISH

TO MATCH (E). CONFIRM

INSTALL DOES NOT REQUIRE

IN-WALL BLOCKING. BASIS OF

DESIGN: WINGIT

(E) TOILET ACCESSORIES

J

D C

B E

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :22

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A5.20

INTERIOR ELEVATIONS -

SECTOR B

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

SCALE: 1/4" = 1'-0"

1B

INTRO TO ROBOTICS B101 (CON'T.)

1C 1D

SCALE: 1/4" = 1'-0"

1E

INTRO TO ROBOTICS B101

1A

2C

SCALE: 1/4" = 1'-0"

2D

INTRO TO ROBOTICS B101D

2A 2B

SCALE: 1/4" = 1'-0" 3DTYP. (E) TOILET WALL

OPENOPEN

AWP-2AWP-2

6' -1

0" 4"

TYP.

EQ

TYP.

EQ

P-1

AWP-2AWP-2

P-1

WS2

4x4 MB

EQ EQP-1

TS-1 TS-1

EQ EQ

TS-1

FILL

WS2

AWP-1 AWP-1 AWP-1

P-1

P-1

P-1

AWP-1

3' -0

6'

-1 0"

EQ. 4'-0" EQ. 4'-0"

PRODUCTION CURTAIN TRACK

PATCH AND REPAIR WALL AS NEEDED AT

REMOVED PAPER TOWEL DISPENSER

WS2 WS2 WS2

WS2 WS2 WS2

AWP-1 AWP-1

P-1

AWP-1AWP-1AWP-1AWP-16'

-1

0" 3'

-0

TYP.

4'-0"

EQ

AWP-1

EQ

AWP-1

P-1

AWP-1AWP-1AWP-1

P-1 P-1

3' -0

6'

-2

EQ.EQ.

EQ. EQ.

PATCH AND PAINT AS NEEDED

WHERE CASEWORK AND

PLUMBING REMOVED

2" 2"

CORNER GUARD CORNER GUARD

P-1

AWP-1

P-1

PATCH AND REPAIR WALL AS

NEEDED WHERE CASEWORK

AND PLUMBING REMOVED.

EQ EQ

ALIGN AWP EDGES TO DOOR AND WINDOW FRAMES, TYP.

AWP-1 AWP-1 AWP-1 AWP-1AWP-1AWP-1AWP-1

4X8 MB WS2

3'-4"(4) EQ. SPACED PANELS

MOUNT ROOM SIGN TO DOOR

3'-4"

CORNER GUARD

P-1

WS2

P-1

AWP-2AWP-2WALL INFILL PER PLANS

P-1

REPLACE FULL WALL OF WALL BASE TO MATCH (E)

P-1 P-1 P-1 P-1

P-1

18"W x23"D x34" H

6'-2"

A9.10

AV EQUIPMENT RACK,

SEE AV, TECHNOLOGY, ELECTRICAL

ON AIR

CL

8' -0

P-1

WS2

PLASTIC LAMINATE

COUNTERTOP (PL-1)

MAX.

4'-0" O.C.

P-1 P-1

P-1

ON AIR LIGHT -

SEE ELECTRICAL.

1WS2

ON AIR

CL

EQEQ

8' -0

P-1

4'x4' TB-1

SHEET NOTES:LEGEND:MOUNTING HEIGHTS:

P-X

CONTROL JOINTCJ

TACKBOARDTB-X

PAINT COLOR (P-X)

PLASTIC LAMINATE (PL-X)

OWNER FURNISHED,

OWNER INSTALLEDOFOI

OWNER FURNISHED,

CONTRACTOR INSTALLEDOFCI

CASEWORK TYPEXX#X

WS1 ROLLER SHADES -

MANUAL

WS2 BLACKOUT SHADES -

MANUAL

FIRE EXTINGUISHER CABINETFEC-X

FEC-B

PL-X

WINDOW COVERINGS:

WCT-X FINISH MATERIAL PER

FINISH LEGEND

TS-2

TS-1

AWP-2

AWP-1

TACKSURFACE

TACKSURFACE

CUSTOM GRAPHIC

ACOUSTIC WALL

PANEL

TACKABLE

ACOUSTIC WALL

PANEL

FIBER

REINFORCED

PANEL

FRP-1

1.

2.

3.

4.

5.

6.

7.

MATERIALS WHICH ARE IN SIMILAR LOCATIONS ARE NOT NOTED AT EVERY

OCCURRENCE.

SEE FINISH FLOOR PLANS, REFLECTED CEILING PLANS, INTERIOR ELEVATIONS

AND FINISH LEGEND FOR ADDITIONAL INFORMATION.

SEE DOOR AND FRAME TYPES FOR ADDITIONAL INFORMATION AND REFERENCE

TO DETAILS.

DOOR SWINGS SHOWN ON ELEVATIONS ARE FOR REFERENCE ONLY- SEE FLOOR

PLANS.

ALL WALLS NOT ELEVATED OR TAGGED TO BE PAINTED P-1 (UNLESS NOTED

OTHERWISE).

MECHANICAL GRILLES AND ACCESS PANELS IN WALLS SHALL MATCH THE COLOR

OF THE WALL WHERE LOCATED, UNLESS NOTED OTHERWISE.

PROVIDE SOLID 2X BLOCKING AT ALL WALL MOUNTED ITEMS.

8. ALL COUNTERS TO BE PL-1, UNLESS NOTED OTHERWISE.

9. ALL CABINETS TO BE PL-2, UNLESS NOTED OTHERWISE.

10. SEE FINISH FLOOR PLANS FOR WALL BASE DESIGNATIONS.

11. ALL NEW WALLS TO HAVE IMPACT RESISTANT GYPSUM BOARD UP TO 4'-0" AFF.

1.

2.

HEIGHTS TYPICAL, UNLESS NOTED OTHERWISE.

PROVIDE BLOCKING PER SHEET NOTES AND PROJECT MANUAL.

WHERE BLOCKING IS SHOWN, PROVIDE BLOCKING AS INDICATED.

4'

8" R

.O

3' -1

0"

8' -0

5' -0

SIGNAGE, SEE

SIGNAGE SCHEDULE

SPEAKER

PULL

STATION

MARKER

BOARDTACKBOARD

7' -2

EQ EQ

FLAT PANEL MONITOR (OFCI)

BLOCKING PER MOUNTING

BRACKET REQUIRMENTS

8' -2

CLOCK (OFOI)

POWER/DATA PER ELEC & TECH, SEE

ELEC & TECH FOR HEIGHTS, VERIFY

WITH MANUFACTURER

FLAT PANEL MONITOR (OFCI) &

MOUNTING BRACKET (OFCI)

CUSTOM VINYL

GRAPHIC ON

GLAZING, APPLY ON

NON-CORRIDOR SIDE,

SEAL EDGES

LABORATORY GRADE

COMPACT LAMINATE (CPL-X)

CPL-X

J

D C

B E

ON AIR

CL

8' -0

EQEQ

PORTLAND, OREGON

E

RE

DAVID A. JOHNSON

T

AT T

S

G

RE

SI

HC

OGEROOF

N

E

TC

TI

RADE

date phase revisions date project

1/2 9/2

6 4

:16 :24

P M

Au tod es k D oc s:/

/25

3-

4 O

CH

S

CT

E Re no /O

CS

D

Or eg on C ity H

S

EC

.rv t

A5.30

INTERIOR ELEVATIONS -

SECTOR C

OR

EG

ON

C

IT

Y

HI

GH

SC

HO

OL

C

TE

T

5-

5-

OR

EG

ON

C

IT

Y

SC

HO

OL

D

IS

TR

IC

T

1/30/2026 25003-154

1 S B

EA

VE

RC

RE

EK

R

D, O

RE

GO

N

CI

TY

, O

R

PERMIT SET

3A

SCALE: 1/4" = 1'-0"

3D

PODCAST/RECORDING ROOM C101E

2B2A

1C1B

SCALE: 1/4" = 1'-0"

1D

DIGITAL MEDIA - PRODUCTION STUDIO C101

SCALE: 1/4" = 1'-0"

1A

DIGITAL MEDIA - PRODUCTION STUDIO C101 (CON'T.)

3B 3C4B

5A 5B 5C

SCALE: 1/4" = 1'-0"

5D

STORAGE C101G

SCALE: 1/4" = 1'-0"

2D

CONTROL ROOM C101D

2C

6A

SCALE: 1/4" = 1'-0"

6D

DIGITAL MEDIA - VESTIBULE

6C6B

SCALE: 1/4" = 1'-0"

4C

DIGITAL MEDIA - STAFF HALL

P-1P-1

36"W x 24"D x 86" H (TOTAL OF (7)

A9.10P-1 P-1 P-1

MB-1 MB-1

8'-0" 8"

4' -0

"TB-1

4'x4'

TB-1

4'x6'

P-1

EQ EQ

P-1

P-1

WS1 WS1 WS1

WS1 WS1 WS1

P-1

CHAIN LINK FENCE

WITH LOCKABLE GATE.

4" 3'

-4

3' -4

3'

-0

FASTEN TOP OF POST TO

STRUCTURAL DECK ABOVE,

EA POST, SEE STRUCTURAL.

FASTEN BOTTOM OF POST

TO CONC. FLOOR, TYP.

'-7

" V

IF

2" GAP TO WALL 2" GAP TO WALL

EQ EQ 3'-2" 2'-4"

ACT CEILING, HEIGHT PER RCP

P-1P-1

WS2

TS-1

P-1

TS-1 TS-1

6' -1

0" 4"

12'-0"

EQ EQ EQ

P-1

WS2

WS2

P-1P-1P-1

WS…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .