This document provides the lock standards and specifications for a project to maintain paint on the exterior of Building 5257 at Joint Base Elmendorf-Richardson in Alaska. The project includes removing and disposing of lead-based paint from various exterior surfaces in accordance with state and federal regulations. It also involves surface preparation, applying one primer coat and two final coats of paint to exterior walls, doors, overhead doors, and other metal and wood components. The specified colors are Rock Tan for field areas and Sorrel Brown for accents.
The document outlines the required lock and hardware types for different areas. Standard office locks must be grade 1 cylindrical or mortise locks. Heavy duty locks are specified for storage and mechanical rooms. Electronic magstripe locks are required for dormitory sleeping rooms and common entry areas. Fire rated panic hardware without a dog-down feature is specified for all fire stairwell and corridor doors. Non-fire rated exit hardware must have the capability to be locked, unlocked, or left in passage mode. A patented core system is also required. The solicitation number for this project through the Department of the Air Force Pacific Air Forces is FA500021R0047.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 5 Amendment 01 Contractor Questions and Answers.pdf | ||
| Attachment 3 Amendment 01 Floor Plan.pdf | ||
| Attachment 4 Amendment 01 Pre-Bid Site Visit Sign In.pdf | ||
| Attachment 1 Amendment 01 SOW.pdf | ||
| Amendment 0001 FA500021R00470001 SF 30.pdf | ||
| Attachment 2 Amendment 01 Drawings.pdf | ||
| Solicitation - FA500021R0047.pdf | ||
| Atch 02 Statement of Work.pdf | ||
| Atch 05 AF Form 66.pdf | ||
| Atch 06 Environmental Protection JBER 28 Oct 2020 Rev 3.pdf | ||
| Atch 07 Environmental Checklist.pdf | ||
| Atch 08 REVISED JBER CAD_STANDARD.pdf | ||
| Atch 03 Drawings.pdf | ||
| Atch 12 Wage Determination.pdf | ||
| Atch 01 Open Market General Specifications.pdf | ||
| Atch 04 Floor Plan.pdf | ||
| Atch 10 ATC_Test_LBP.pdf | ||
| Atch 11 Contractors Fire Safety Guide.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Oct 3 2017 JBER Lock Standards
Brand Locks utilized on JBER; Best Lock System Suggested Vendor: Best Locks All standard Office Locks must be Grade 1 locks (Office, storage closets, janitorial room etc): Cylindrical
Standard Office Locks 83K7AB4AS3626 Lockset, Heavy Duty
Storeroom Locks 83K7D4AS3626 Lockset, Heavy Duty (Communications, Electrical & Mechanical Rooms)
Where applicable the 93K Series lever handle may be used to comply with ADA specifications.
Standard Deadbolt:
Deadbolt 83T7KSTK626 Deadbolt, Tubular Deadbolt 83T7KSTK626D5 Deadbolt, Tubular, Drive In
Mortise lock Grade 1, Mortis Body Locks,“Dormitory Function” for all offices and “Store Room Function” for storage and mechanical rooms.
Mortise 45H7T4J626 Mortis Lock, “Round Knob” Mortise 45H7T15J626 Mortis Lock, “Lever Knob ADA
Mortise 45H7D4J626 Mortis Lock, “Round Knob” Mortise 45H7D15J626 Mortis Lock, “Lever Knob” ADA
Electronic Locks: (NO SUBSTITUTION ALLOWED) Dormitories
Basis G Magstripe, Cylindrical Lock, Knob (Sleeping Rooms) 83KG7DV4MSS3626
Basis G Magstripe, Mortise Lock (Common Entry to Sleeping Rooms)
45HG7TV4MS626KOS
Where applicable the 45HG7TV15MS626KOS may be used to comply with ADA specifications.
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257 Attachment 9 - Lock Standard
Where applicable the 93K Series may be used to comply with ADA specifications.
Basis G Magstripe, Mortise Lock (Panic Hardware) EXG7EV15-MS-626-RHR-VD9- RM-SH, Right hand Von Duprin. EXG7EV15-MS-626-LHR-VD9-RM-SH, Left hand Von Duprin.
Main Base
Main Entry To Offices:
Basis V Magstripe, Mortise Hardware Lock (45HBV7TV15MS-626-KOS-TRK-2) Where applicable they may be used to comply with ADA specifications.
Interior Office:
Basis V Magstripe, Cylindrical Lock, Knob (83KBV7DV15-MS-STK-626-TRK-2) Where applicable the 93K Series may be used to comply with ADA specifications.
Optional Basis V Magstripe, Mortise Hardware Lock (45HBV7DV15MS-626-KOS-TRK-2) Where applicable they may be used to comply with ADA specifications.
Perimeters / Stairwells:
Basis V Magstripe, Panic Hardware Lock ( EXBV7EV15-MS-626-RHR-VD9-RM-M) Where applicable they may be used to comply with ADA specifications.
Suggested Hardware: Von Duprin 99 Fire Rated Panic Hardware:
All Fire Stairwell Doors Hardware / Corridor Doors Hardware to be of Grade 1 design:
All doors to have UL listed Fire Rated Panic Hardware with no dog down feature, with outside trim to also be UL listed Fire Rated Hardware with or without key override.
Where applicable outside trim to meet ADA Standards and finish to be 626 / Satin Chrome.
Non Fire Rated Exit Hardware ( Panic ) to be of Grade 1 design:
Exit Hardware to have the capability to be locked or unlock with outside trim and be able to dog down the device from the inside with a hex key or operating key in order to leave in the passage mode when applicable. Outside trim to meet ADA Standards where applicable and finish to be 626 / Satin Chrome.
Patented Core System ( MX8 ) (NO SUBSTITUTION ALLOWED)
MX8 system to apply to all hardware that will have the capability for a key override or key access. System to be ordered as BEST 7 pin IC / 26D. Cores paid for by contractor But ordered by Lock Shop and installed by the lock shop.
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257 Attachment 9 - Lock Standard