Atch 03 Drawings.pdf
PDF 8 MB Posted
- Attached to
- FXSB 21-1051 MAINTAIN PAINT EXTERIOR B5257 Federal contract opportunity
- Solicitation number
- FA500021R0047
About this file
This solicitation package includes drawings and specifications for a project to maintain paint on the exterior of Building 5257 at Joint Base Elmendorf-Richardson in Alaska. The project consists of removing lead-based paint from metal and concrete surfaces; preparing all exterior wall surfaces, doors, overhead doors, metal siding, louvers and piping; and applying one primer coat and two finish coats of paint. Colors will be G11 Rock Tan for field areas and 1236 Sorrel Brown for accents. The solicitation also includes demolition and installation of a new exterior door and frame, and electrical repairs to a supervisor's office. The solicitation is identified as number FA500021R0047 and is issued by the Department of the Air Force Pacific Air Forces for project FXSB 21-1051 to maintain paint on Building 5257. The drawings provide plans, sections, details and photographs of the building and areas to be painted.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 5 Amendment 01 Contractor Questions and Answers.pdf | ||
| Attachment 3 Amendment 01 Floor Plan.pdf | ||
| Amendment 0001 FA500021R00470001 SF 30.pdf | ||
| Attachment 2 Amendment 01 Drawings.pdf | ||
| Attachment 4 Amendment 01 Pre-Bid Site Visit Sign In.pdf | ||
| Attachment 1 Amendment 01 SOW.pdf | ||
| Solicitation - FA500021R0047.pdf | ||
| Atch 02 Statement of Work.pdf | ||
| Atch 05 AF Form 66.pdf | ||
| Atch 06 Environmental Protection JBER 28 Oct 2020 Rev 3.pdf | ||
| Atch 07 Environmental Checklist.pdf | ||
| Atch 08 REVISED JBER CAD_STANDARD.pdf | ||
| Atch 9 JBER Lock Standards (03OCT2017).pdf | ||
| Atch 10 ATC_Test_LBP.pdf | ||
| Atch 11 Contractors Fire Safety Guide.pdf | ||
| Atch 12 Wage Determination.pdf | ||
| Atch 01 Open Market General Specifications.pdf | ||
| Atch 04 Floor Plan.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JOINT BASE ELMENDORF-RICHARDSON
673RD CIVIL ENGINEER SQUADRON
PROJECT LOCATION
KEY PLAN
(SEE KEY PLAN)
TRUE
NORTH
MAP KEY
LOCATION DESCRIPTION
RICHARDSON VISITORS GATE
ARCTIC VALLEY GATE GLENN HWY SOUTHBOUND EXIT
ELMENDORF VISITORS GATE
654 6TH STREET: FIRE STATION 4
8517 20TH STREET: SECURITY FORCES
730 QUARTERMASTER ROAD: 673D CES CONTRACT MANAGEMENT
10480 SIJAN AVENUE: CONTRACTING
PROJECT NOTES:
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
1. AT NO TIME WILL THE CONTRACTORS WORK, STORAGE OF MATERIALS, PARKING OF VEHICLES OR OTHER ACTIVITIES BE ALLOWED TO INTERFERE WITH THE WORK ACTIVITIES OF
GOVERNMENT PERSONNEL OR TO DAMAGE GOVERNMENT OR PRIVATE PROPERTY.
2. PARKING SHALL BE ALLOWED IN APPROVED PARKING SPACES ONLY. VEHICLES OTHERWISE PARKED SO WILL BE REMOVED AT THE CONTRACTOR'S EXPENSE.
3. THE CONTRACTOR'S MATERIALS AND EQUIPMENT SHALL NOT BE STORED WITHIN 20 FEET O F ANY BUILDING, OBSTRUCT FIRE EXITS OR OTHERWISE INTERFERE WITH FIRE FIGHTING
FACILITIES. ANY MATERIALS, EQUIPMENT OR VEHICLES DOING SO WILL BE REMOVED AT THE CONTRACTOR'S EXPENSE.
4. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE WORK AREA FREE FROM ACCUMULATION OF WASTE MATERIALS. DEBRIS SHALL BE REMOVED ON A DAILY BASIS.
5. ALL WELDING AND / OR THE USE OF FLAME PRODUCING DEVICES SHALL BE CLEARED THROUGH THE FIRE DEPARTMENT.
6. ALL CONSTRUCTION PERMITS, FEES AND COORDINATION OF ANCILLARY ITEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
7. THE WORK OF THIS CONTRACT SHALL COMPLY WITH APPLICABLE FEDERAL, STATE AND LOCAL CODES OR STANDARDS. ALL WORK SHALL COMPLY WITH THE MOST RECENT ADOPTED
EDITION OF THE CODES OR STANDARDS THAT FOLLOW:
EPA STANDARDS INTERNATIONAL BUILDING CODE INTERNATIONAL FUEL GAS CODE INTERNATIONAL MECHANICAL CODE INTERNATIONAL PLUMBING CODE
NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL SAFETY CODE NATIONAL FIRE PROTECTION ASSOCIATION OSHA STANDARDS
SHEET METAL AND AIR CONDITIONING CONTRACTOR'S NATIONAL ASSOCIATION INC. FIRE CODES
A B C D E F G H
F I L
E
N
O
I
SHEET
REFERENCE
NUMBER
ARCH
E1
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
D E
S C
R I P
T I O
N
R E
V I S
I O
N S
RICHARDSON, ALASKA
AF CONTRACT NUMBER:
FACILITY NO:
D A
T E
A P
P R
O V
E R
JOINT BASE ELMENDORF
PROJ. MGR:
DRAFTER:
CHECKER:
PROJ. ENGR:
DATE:
DATE:
DATE:
DATE:
DESIGNER LOGO
AIR FORCE
S Y
M B
O L
D A
T E
J K
G-001
LOCATION PLAN
AND SCHEDULE
OF DRAWINGS
MAINTAIN
PAINT
EXTERIOR
BLDG 5257
FXSB211051G001.dwg
FXSB 21-1051
NONE
HENDLER
COLBURN
TYLER
CAUSEWAY
SCHEDULE OF DRAWINGS
SHEET REFERENCE NUMBER SHEET TITLE
G-001 LOCATION PLAN AND SCHEDULE OF DRAWING
C-100 SITE PLAN
C-101 CAUSEWAY PLAN, SECTION AND ISOMETRIC EXHIBIT DRAWING
S-100 REPAIR DETAILS
A-100 EXTERIOR WALL PLAN
A-200 EXTERIOR ELEVATIONS EXHIBIT DRAWING
A-900 EXTERIOR PHOTOS
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257 Attachment 3 - Drawings
TRUE
NORTH
A B C D E F G H
F I L
E
N
O
I
SHEET
REFERENCE
NUMBER
ARCH
E1
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
D E
S C
R I P
T I O
N
R E
V I S
I O
N S
RICHARDSON, ALASKA
AF CONTRACT NUMBER:
FACILITY NO:
D A
T E
A P
P R
O V
E R
JOINT BASE ELMENDORF
PROJ. MGR:
DRAFTER:
CHECKER:
PROJ. ENGR:
DATE:
DATE:
DATE:
DATE:
DESIGNER LOGO
AIR FORCE
S Y
M B
O L
D A
T E
J K
C-100
SITE PLAN
MAINTAIN
PAINT
EXTERIOR
BLDG 5257
FXSB211051C100.dwg
FXSB 21-1051
NONE
HENDLER
COLBURN
TYLER
CAUSEWAY
A900
A900
A900
A900
A900
A900
A900
EQUIPMENT
YARD
9TH STREET
F I N
L E
T T
E R
A
V E
SHEET NOTES:
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
THE FOLLOWING ARE NOT TO BE CLEANED AND RE-PAINTED IN ANY MANNER:
1. ELECTRICAL PANELS, ELECTRIC METER AND ASSOCIATED CONDUIT.
2. ALL WINDOWS WITH SECURITY BARS / SCREENS COVERING THEM.
3. HVAC UNIT, SUPPORTING STANDS AND WORK PLATFORMS / LADDERS.
4. ALL EXTERIOR LIGHT FIXTURES.
5. ALL SIGNS SHALL BE REMOVED PRIOR TO SURFACE PREPARATION AND
CLEANED AND RE-INSTALLED AFTER CURE OF FINAL FINISH COAT.
6. COIL / ROLL-UP BAY DOORS.
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257 Attachment 3 - Drawings
1025779599C Callout The Causeway from BLDG 5257 to 5250 will be demolished and a new Causeway will be constructed under an existing project and is not part of this project.
1025779599C Text Box
A B C D E F G H
F I L
E
N
O
I
SHEET
REFERENCE
NUMBER
ARCH
E1
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
D E
S C
R I P
T I O
N
R E
V I S
I O
N S
RICHARDSON, ALASKA
AF CONTRACT NUMBER:
FACILITY NO:
D A
T E
A P
P R
O V
E R
JOINT BASE ELMENDORF
PROJ. MGR:
DRAFTER:
CHECKER:
PROJ. ENGR:
DATE:
DATE:
DATE:
DATE:
DESIGNER LOGO
AIR FORCE
S Y
M B
O L
D A
T E
J K
C-101
CAUSEWAY
PLAN, SECTION
AND ISOMETRIC
MAINTAIN
PAINT
EXTERIOR
BLDG 5257
FXSB211051C101.dwg
FXSB 21-1051
NOT TO SCALE
HENDLER
COLBURN
TYLER
A
S
B
U
I
L
T
X
H
I
B
I
C
O
N
T
R
A
C
T
S
H
A
F
E
D
R
I
Y
M
E
N
S
I
O
N
S
SCALE: NOT TO SCALE
CAUSEWAY PLAN
SCALE: NOT TO SCALE
CAUSEWAY PLAN ENLARGED
SCALE: NOT TO SCALE
CAUSEWAY PLAN @ BENDS
SCALE: NOT TO SCALE
CAUSEWAY ISOMETRIC
SCALE: NOT TO SCALE
CAUSEWAY SECTION TYPICAL
SHEET NOTES:
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
THE FOLLOWING ARE NOT TO BE CLEANED AND RE-PAINTED IN ANY MANNER:
1. ELECTRICAL PANELS, ELECTRIC METER AND ASSOCIATED CONDUIT.
2. ALL WINDOWS WITH SECURITY BARS / SCREENS COVERING THEM.
3. HVAC UNIT, SUPPORTING STANDS AND WORK PLATFORMS / LADDERS.
4. ALL EXTERIOR LIGHT FIXTURES.
5. ALL SIGNS SHALL BE REMOVED PRIOR TO SURFACE PREPARATION AND
CLEANED AND RE-INSTALLED AFTER CURE OF FINAL FINISH COAT.
6. COIL / ROLL-UP BAY DOORS.
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257
SHEET NOTES:
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
SCALE: NONE
CONCRETE REPAIR - SEVERE CRACKS
D-1
NOTES:
A. ROUTE A V-GROOVE AT CRACK SURFACE UNTIL SOUND MATERIAL IS REACHED. CLEAN
CRACKS.
B. FOR EPOXY INJECTION, APPLY SURFACE SEAL OVER ALL EXTERIOR FACES OF CRACK.
INSTALL INJECTION AND VENTING PORTS PER MANUFACTURER'S INSTRUCTIONS.
C. INJECT EPOXY MEETING THE REQUIREMENTS OF ACI 584.12 FOLLOWING MANUFACTURER'S
INSTRUCTIONS.
1. (E) CONC. WALL OR COL.
2. PARTIAL DEPTH CRACK.
3. THRU-WALL CRACK.
4. V-GROOVE. NOTE A.
5. SEAL. NOTE B.
NOTES:
A. CONTRACTOR TO PROVIDE TEMPORARY SHORING AS REQUIRED TO SUPPORT WALL
DURING RESHORING.
B. CAREFULLY RAKE OUT EXISTING MORTAR USING NON-IMPACT TOOLS ONLY. CLEAN
JOINTS PRIOR TO PLACING MORTAR.
C. FOR FULL-DEPTH REPOINTING, REPOINT IN STAGES ALLOWING EACH STAGE TO CURE
BEFORE RAKING AND REPOINTING THE NEXT STAGE. PROVIDE TEMPORARY SHIMS AND
SUPPORTS AS NEEDED. REPAIR VOIDS LEFT BY SHIMS AND SUPPORTS WHEN NO
LONGER NEEDED.
1. (E) MASONRY INFILL
2. (E) 1/4" -1/2" MORTAR
JOINT.
3. RAKE JOINT TO
WHICHEVER DEPTH IS
GREATER:
a. 5/8"
b. 2x JOINT WIDTH
c. DEPTH REQUIRED TO
REMOVE PREVIOUSLY
POINTED PORTLAND
CEMENT MORTAR.
SCALE: NONE
MASONRY REPOINTING
D-4
A B C D E F G H
F I L
E
N
O
I
SHEET
REFERENCE
NUMBER
ARCH
E1
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
D E
S C
R I P
T I O
N
R E
V I S
I O
N S
RICHARDSON, ALASKA
AF CONTRACT NUMBER:
FACILITY NO:
D A
T E
A P
P R
O V
E R
JOINT BASE ELMENDORF
PROJ. MGR:
DRAFTER:
CHECKER:
PROJ. ENGR:
DATE:
DATE:
DATE:
DATE:
DESIGNER LOGO
AIR FORCE
S Y
M B
O L
D A
T E
J K
S-100
REPAIR DETAILS
MAINTAIN
PAINT
EXTERIOR
BLDG 5257
FXSB211051S100.dwg
FXSB 21-1051
NOT TO SCALE
HENDLER
COLBURN
TYLER
THE FOLLOWING ARE NOT TO BE CLEANED AND RE-PAINTED IN ANY MANNER:
1. ELECTRICAL PANELS, ELECTRIC METER AND ASSOCIATED CONDUIT.
2. ALL WINDOWS WITH SECURITY BARS / SCREENS COVERING THEM.
3. HVAC UNIT, SUPPORTING STANDS AND WORK PLATFORMS / LADDERS.
4. ALL EXTERIOR LIGHT FIXTURES.
5. ALL SIGNS SHALL BE REMOVED PRIOR TO SURFACE PREPARATION AND
CLEANED AND RE-INSTALLED AFTER CURE OF FINAL FINISH COAT.
6. COIL / ROLL-UP BAY DOORS.
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257 Attachment 3 - Drawings
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
A B C D E F G H
F I L
E
N
O
I
SHEET
REFERENCE
NUMBER
ARCH
E1
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
D E
S C
R I P
T I O
N
R E
V I S
I O
N S
RICHARDSON, ALASKA
AF CONTRACT NUMBER:
FACILITY NO:
D A
T E
A P
P R
O V
E R
JOINT BASE ELMENDORF
PROJ. MGR:
DRAFTER:
CHECKER:
PROJ. ENGR:
DATE:
DATE:
DATE:
DATE:
DESIGNER LOGO
AIR FORCE
S Y
M B
O L
D A
T E
J K
A-100
EXTERIOR WALL
PLAN
MAINTAIN
PAINT
EXTERIOR
BLDG 5257
FXSB211051A100.dwg
FXSB 21-1051
NOT TO SCALE
HENDLER
COLBURN
TYLER
SCALE: NOT TO SCALE
EXTERIOR WALL PLAN
TRUE
NORTH
14'-0" WIDE X 16'-0"
TALL OVERHEAD
COILING DOOR
14'-0" WIDE X 14'-0"
TALL OVERHEAD
COILING DOOR
VEHICLE RAMP
14'-0" WIDE X 16'-0" TALL
COMMERCIAL STEEL
INSULATED SECTIONAL
DOOR
SECTIONAL BAY DOOR
3 EACH SECTIONAL BAY
DOORS
SECTIONAL BAY DOOR
SECTIONAL BAY DOOR
COIL / ROLL-UP BAY
DOOR NOT TO BE
PAINTED
VEHICLE RAMP
C
A
U
S
E
W
A
Y
SHEET NOTES:
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
THE FOLLOWING ARE NOT TO BE CLEANED AND RE-PAINTED IN ANY MANNER:
1. ELECTRICAL PANELS, ELECTRIC METER AND ASSOCIATED CONDUIT.
2. ALL WINDOWS WITH SECURITY BARS / SCREENS COVERING THEM.
3. HVAC UNIT, SUPPORTING STANDS AND WORK PLATFORMS / LADDERS.
4. ALL EXTERIOR LIGHT FIXTURES.
5. ALL SIGNS SHALL BE REMOVED PRIOR TO SURFACE PREPARATION AND
CLEANED AND RE-INSTALLED AFTER CURE OF FINAL FINISH COAT.
6. COIL / ROLL-UP BAY DOORS.
DOOR NOT TO BE PAINTED
DOORS NOT TO BE PAINTED
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257
B
U
I
X
H
I
B
C
N
T
R
A
C
T
H
A
E
R
I
Y
M
E
N
S
I
O
N
S
A B C D E F G H
F I L
E
N
O
I
SHEET
REFERENCE
NUMBER
ARCH
E1
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
D E
S C
R I P
T I O
N
R E
V I S
I O
N S
RICHARDSON, ALASKA
AF CONTRACT NUMBER:
FACILITY NO:
D A
T E
A P
P R
O V
E R
JOINT BASE ELMENDORF
PROJ. MGR:
DRAFTER:
CHECKER:
PROJ. ENGR:
DATE:
DATE:
DATE:
DATE:
DESIGNER LOGO
AIR FORCE
S Y
M B
O L
D A
T E
J K
A-200
EXTERIOR
ELEVATIONS
MAINTAIN
PAINT
EXTERIOR
BLDG 5257
FXSB211051A200.dwg
FXSB 21-1051
NOT TO SCALE
HENDLER
COLBURN
TYLER
SHEET NOTES:
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
THE FOLLOWING ARE NOT TO BE CLEANED AND RE-PAINTED IN ANY MANNER:
1. ELECTRICAL PANELS, ELECTRIC METER AND ASSOCIATED CONDUIT.
2. ALL WINDOWS WITH SECURITY BARS / SCREENS COVERING THEM.
3. HVAC UNIT, SUPPORTING STANDS AND WORK PLATFORMS / LADDERS.
4. ALL EXTERIOR LIGHT FIXTURES.
5. ALL SIGNS SHALL BE REMOVED PRIOR TO SURFACE PREPARATION AND
CLEANED AND RE-INSTALLED AFTER CURE OF FINAL FINISH COAT.
6. COIL / ROLL-UP BAY DOORS.
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257
A B C D E F G H
F I L
E
N
O
I
SHEET
REFERENCE
NUMBER
ARCH
E1
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
D E
S C
R I P
T I O
N
R E
V I S
I O
N S
RICHARDSON, ALASKA
AF CONTRACT NUMBER:
FACILITY NO:
D A
T E
A P
P R
O V
E R
JOINT BASE ELMENDORF
PROJ. MGR:
DRAFTER:
CHECKER:
PROJ. ENGR:
DATE:
DATE:
DATE:
DATE:
DESIGNER LOGO
AIR FORCE
S Y
M B
O L
D A
T E
J K
A-900
EXTERIOR
PHOTOS
MAINTAIN
PAINT
EXTERIOR
BLDG 5257
FXSB211051A900.dwg
FXSB 21-1051
NOT TO SCALE
HENDLER
COLBURN
TYLER
SCALE: NOT TO SCALE
EXTERIOR ELEVATION SOUTH FACING
SCALE: NOT TO SCALE
EXTERIOR ELEVATION @ WEST FACING CAUSEWAY
SCALE: NOT TO SCALE
EXTERIOR ELEVATION @ EAST FACING CAUSEWAY
SCALE: NOT TO SCALE
EXTERIOR ELEVATION SOUTH FACING
SCALE: NOT TO SCALE
EXTERIOR ELEVATION @ EAST END
SCALE: NOT TO SCALE
EXTERIOR PANORAMIC ELEVATION ALONG 9TH STREET
SCALE: NOT TO SCALE
EXTERIOR ELEVATION & WEST END
SCALE: NOT TO SCALE
TYP. SIDING & FOUNDATION DAMAGE
SCALE: NOT TO SCALE
TYP. EXTERIOR CORRAGATED SIDING
SCALE: NOT TO SCALE
TYPICAL CONCRETE PAINT DAMAGE
FOUNDATION FOUNDATION
SHEET NOTES:
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.
THE FOLLOWING ARE NOT TO BE CLEANED AND RE-PAINTED IN ANY MANNER:
1. ELECTRICAL PANELS, ELECTRIC METER AND ASSOCIATED CONDUIT.
2. ALL WINDOWS WITH SECURITY BARS / SCREENS COVERING THEM.
3. HVAC UNIT, SUPPORTING STANDS AND WORK PLATFORMS / LADDERS.
4. ALL EXTERIOR LIGHT FIXTURES.
5. ALL SIGNS SHALL BE REMOVED PRIOR TO SURFACE PREPARATION AND
CLEANED AND RE-INSTALLED AFTER CURE OF FINAL FINISH COAT.
6. COIL / ROLL-UP BAY DOORS.
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257
AS-BUILT EXHIBIT
CONTRACTOR SHALL FIELD
VERIFY ALL DIMENSIONS
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257
VERIFY ALL DIMENSIONS
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257
VERIFY ALL DIMENSIONS
FA500021R0047 FXSB 21-1051 Maintain Paint Exterior B5257
| Drawings |
| G-001 |
| Sheets and Views |
| Layout1 |
| C-100 |
| Sheets and Views |
| Layout1 |
| C-101 |
| Sheets and Views |
| Layout1 |
| S-100 |
| Sheets and Views |
| Layout1 |
| A-100 |
| Sheets and Views |
| Layout1 |
| A-200 |
| Sheets and Views |
| Layout1 |
| A-900 |
| Sheets and Views |
| Layout1 |
| elm_d038_p1_ef0057 |
| elm_d038_p1_ef0060 |
| Panel F elm_d038_p1_ef0056 |
File details come from the government source that posted it. Updated .