Atch 4_ CB 5907_ACM_LBP_Report 2013.pdf
PDF 2 MB Posted
- Attached to
- Demo w/ Abatement B5907 Camp Bullis
- Solicitation number
- FA301626Q0157
About this file
This document is an environmental survey report conducted by Argus Environmental Consultants, LLC on Building 5907 at Joint Base San Antonio (JBSA) - Camp Bullis in San Antonio, Texas.
The survey included a limited asbestos and lead-based paint (LBP) assessment of interior materials within the latrine building. For the asbestos evaluation, Argus Environmental performed visual assessment of interior finish materials, identified suspect asbestos-containing materials (ACM) into homogeneous areas per EPA guidelines, collected nine random non-destructive bulk samples from three homogenous areas (wall texture, gypsum board, and joint compound), and conducted laboratory analysis using Polarized Light Microscopy (PLM) with EPA Methods 600 and 400. For the LBP survey, the firm completed visual evaluation of interior paint finishes, identified suspect paint into homogenous areas by color and substrate, collected four random non-destructive paint samples from metal pipe, gypsum board wall, wood window frame, and wood door, and performed laboratory analysis using Flame Atomic Absorption (EPA Method SW 8463050B*/7000B). The survey was performed on May 15, 2013 by Bonnie L. Lee, a Texas DSHS-licensed asbestos and lead inspector.
Key findings indicate that asbestos was not detected in any of the nine bulk samples analyzed. However, lead-based paint exceeding the EPA's minimum regulatory threshold of 0.5% by weight was identified in sample 5907-L2 (gypsum board wall with white paint) at 0.51% lead by weight. The remaining three lead samples (metal pipe, wood window frame, and wood door) tested below regulatory thresholds. Recommendations require contractors to be informed of the absence of ACM and the presence of LBP on the white gypsum board wall surface. The report notes that OSHA 29 CFR 1926.62 regulations apply, and contractors must implement appropriate personal protective measures. The survey's scope was limited to sampled materials only, with no warranty provided for unsampled areas, inaccessible spaces, or materials hidden behind walls or flooring.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building 5907, JBSA-CB 2
The asbestos and lead-based paint survey was performed on 15 May 2013 by Bonnie L.
Lee, Texas DSHS Asbestos Inspector License #602834 and Texas DSHS Lead Inspector
License #2060868.
Bulk Samples:
Asbestos
Nine samples were collected from inside Building 5907.
The following homogenous areas were identified and bulk samples collected:
Homogenous
Area
Description
Sample IDs
1 Wall Texture CB5907-H1ABC
2 Gypsum Board CB5907-H2ABC
3 Joint Compound CB5907-H3ABC
Lead
Four samples were collected from inside Building 5907.
The following building painted surfaces were identified as potentially containing LBP and sampled:
Sample ID Description
5907-L1 Metal Pipe – Cream, Green, Yellow
5907-L2 Gypsum Board Wall – White
5907-L3 Wood Window Frame – White, Green
5907-L4 Wood Door – Brown, Gray
Conclusions:
Asbestos was not detected in any sample layer.
Building 5907, JBSA-CB 3
Greater than the EPA’s minimum regulatory level of 0.5% by weight (wt.) was identified by laboratory analysis in the following sample:
Sample ID Description/Location Percent (%) Lead by Weight (wt.)
5907-L2 Gypsum Board Wall - White 0.51%
Lead-based paint was not detected in any of the remaining samples.
Recommendations:
Pursuant to the JBSA FSH and CB Asbestos Operations and Management Plan, inform contractors involved with any construction, demolition, renovation or related activities that
ACM was not identified.
Pursuant to the JBSA FSH and CB LBP Operations and Management Plan, inform contractors involved with any construction, demolition, renovation or related activities that white lead-based paint was identified on the gypsum board wall and any additional building components with the same color. Contractors must ensure appropriate personal protective measures to adequately protect workers and any building occupants, where present.
Regulations from the Occupational Safety and Health Act (OSHA) 29 CFR 1926.62 apply.
If materials are to be disposed of, then additional testing may be required using the Toxicity
Characteristic Leaching Procedure (TCLP) for waste characterization.
Due to the limited nature of this survey, Argus Environmental Consultants, LLC does not warrant the existence or non-existence of ACM or LBP in areas not sampled. For example, destructive sampling, evaluation in any inaccessible areas, or any areas of the building outside the proposed evaluation has not been done. Therefore, any suspect materials hidden in or behind walls, under the flooring or other inaccessible areas are not included in this report. Argus Environmental Consultants, LLC only warrants the existence or non-existence of asbestos and LBP in those materials actually sampled.
During all future renovation, demolition or construction activities, any material(s) suspected to contain asbestos or lead that has not been previously sampled should be evaluated and bulk samples collected for appropriate laboratory analysis prior to disturbance/removal.
This report has been prepared for the exclusive use of Weston Solutions, Inc. and JBSA-
CB and their assigned agents. It and all contents, findings, conclusions and
EMSL Analytical, Inc.
8700 Jameel Road, Suite 190, Houston, TX 77040 Phone/Fax: (713) 686-3635 / (713) 686-3645 http://www.emsl.com houstonlab@emsl.com
151302277
CustomerID: WESO30
CustomerPO:
ProjectID: JBSA-FSH Texas
EMSL Order:
Attn: Owena Yang-Totorica Weston Solutions 70 NE Loop 410 Suite 600 San Antonio, TX 78216-5842
Received: 05/16/13 8:50 AM
Weston (JBSA-CB - Bldg. 5907) Job # 12832.002.129.0005
Fax:
Phone:
Project:
5/30/2013Analysis Date:
Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy
CB5907-H1A
151302277-0001
Latrine - Wall
Texture
White/Beige None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
CB5907-H1B
151302277-0002
Latrine - Wall
Texture
White/Beige None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
CB5907-H1C
151302277-0003
Latrine - Wall
Texture
White/Beige None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
CB5907-H2A
151302277-0004
Latrine - Gypsum
Board
Brown/White None Detected Fibrous
Homogeneous
Cellulose10% Non-fibrous (other)90%
CB5907-H2B
151302277-0005
Latrine - Gypsum
Board
Brown/White None Detected Fibrous
Homogeneous
Cellulose10% Non-fibrous (other)90%
CB5907-H2C
151302277-0006
Latrine - Gypsum Board
White None Detected Fibrous
Homogeneous
Cellulose10% Non-fibrous (other)90%
CB5907-H3A
151302277-0007
Latrine - Joint
Compound
White None Detected Non-Fibrous
Homogeneous
Non-fibrous (other)100%
1Test Report PLM-7.28.7 Printed: 5/30/2013 5:38:42 PM
Michelle Leggett, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Houston, TX NVLAP Lab Code 102106-0, AZ 0925, CO AL-15355, LA 04126, TX 300159
Initial report from 05/30/2013 15:47:00
Jenny Drapela (3) Jason Mote (6) http://www.emsl.com mailto:houstonlab@emsl.com
EMSL Analytical, Inc.
8700 Jameel Road, Suite 190, Houston, TX 77040 Phone/Fax: (713) 686-3635 / (713) 686-3645 http://www.emsl.com houstonlab@emsl.com
151302277
CustomerID: WESO30
CustomerPO:
ProjectID: JBSA-FSH Texas
EMSL Order:
Attn: Owena Yang-Totorica Weston Solutions 70 NE Loop 410 Suite 600 San Antonio, TX 78216-5842
Received: 05/16/13 8:50 AM
Weston (JBSA-CB - Bldg. 5907) Job # 12832.002.129.0005
Fax:
Phone:
Project:
5/30/2013Analysis Date:
Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy
CB5907-H3B
151302277-0008
Latrine - Joint
Compound
White None Detected Non-Fibrous
Homogeneous
Non-fibrous (other)100%
CB5907-H3C
151302277-0009
Latrine - Joint
Compound
White None Detected
Inseparable paint / coating layer included in analysis
Non-Fibrous
Heterogeneous
Non-fibrous (other)100%
2THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.28.7 Printed: 5/30/2013 5:38:42 PM
Michelle Leggett, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Houston, TX NVLAP Lab Code 102106-0, AZ 0925, CO AL-15355, LA 04126, TX 300159
Initial report from 05/30/2013 15:47:00
Jenny Drapela (3) Jason Mote (6) mailto:houstonlab@emsl.com
Client Sample Description ConcentrationLab ID Analyzed
Collected
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.emsl.com cinnaminsonleadlab@emsl.com
Attn: Aimee Kambhu Weston Solutions 70 NE Loop 410 Suite 600 San Antonio, TX 78216-5842
Received: 05/16/13 9:37 AM
WESTON (JBSA-CB-Bldg.5907)
Fax:
Phone:
Project:
5/15/2013Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B*/7000B)
201305108
CustomerID: WESO30
CustomerPO:
ProjectID: JBSA-FSH Texas
EMSL Order:
Site: Metal Pipe Desc: Cream/Green/Yellow
00015907-L1 0.11 % wt5/28/20135/15/2013
Site: Gypsum Board Wall Desc: White
00025907-L2 0.51 % wt5/28/20135/15/2013
Site: Wood Window Frame Desc: White/green
00035907-L3 0.015 % wt5/28/20135/15/2013
Site: Wood Door Desc: Brown/Grey
00045907-L4 0.18 % wt5/28/20135/15/2013
Julie Smith - Laboratory Director NJ-NELAP Accredited:03036 or other approved signatory
Test Report ChmSnglePrm/nQC-7.21.0 Printed: 5/29/2013 1:51:12 PM
Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. The QC data associated with these results included in this report meet the method QC requirements, unless specifically indicated otherwise. Unless noted, results in this report are not blank corrected. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted.
* slight modifications to methods applied. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01
Initial report from 05/29/2013 13:39:50 mailto:cinnaminsonleadlab@emsl.com
Building 5907 - Bulk Sample Diagram
L-2
L-1
L-3
L-4
H1C
H3AB
H2AB
H1AB
H3C
H2C
Legend
Green - Non-Asbestos Sample Locations
Blue - Non-Lead Sample Locations
Purple - Lead Sample Locations
Date: _10/6/14_
10004 Wurzbach Road, Ste. 247 San Antonio, Texas 78230
Consultants, LLCEnvironmental
Building 5907, JBSA-CB 1
CAMP BULLIS BUILDING 5907
PHOTOGRAPHS
LBP
Gypsum Board Wall - White
(0.51% wt. Lead)
Lead-Based Paint – LBP
Weight – wt.
| Binder1.pdf |
| CB 5907 - Asbestos and Lead Based Paint Survey.pdf |
| 5907 |
| CB 5907 - Asbestos and Lead Based Paint Survey |
| 5907 |
| CB 5907 - Asbestos COC.pdf |
| CB 5907 - Asbestos Results.pdf |
| CB 5907 - Bulk Sample Diagram.pdf |
| CB 5907- Photo Report.pdf |
| CB 5907 - Lead Results.pdf |
| CB 5907 - Asbestos and Lead Based Paint Survey.pdf |
| 5907 |
| CB 5907 - Asbestos and Lead Based Paint Survey |
| 5907 |
| CB 5907 - Lead COC.pdf |
| CB 5907- Photo Report.pdf |
File details come from the government source that posted it. Updated .