This document is an environmental survey report conducted by Argus Environmental Consultants, LLC on Building 5907 at Joint Base San Antonio (JBSA) - Camp Bullis in San Antonio, Texas.

The survey included a limited asbestos and lead-based paint (LBP) assessment of interior materials within the latrine building. For the asbestos evaluation, Argus Environmental performed visual assessment of interior finish materials, identified suspect asbestos-containing materials (ACM) into homogeneous areas per EPA guidelines, collected nine random non-destructive bulk samples from three homogenous areas (wall texture, gypsum board, and joint compound), and conducted laboratory analysis using Polarized Light Microscopy (PLM) with EPA Methods 600 and 400. For the LBP survey, the firm completed visual evaluation of interior paint finishes, identified suspect paint into homogenous areas by color and substrate, collected four random non-destructive paint samples from metal pipe, gypsum board wall, wood window frame, and wood door, and performed laboratory analysis using Flame Atomic Absorption (EPA Method SW 8463050B*/7000B). The survey was performed on May 15, 2013 by Bonnie L. Lee, a Texas DSHS-licensed asbestos and lead inspector.

Key findings indicate that asbestos was not detected in any of the nine bulk samples analyzed. However, lead-based paint exceeding the EPA's minimum regulatory threshold of 0.5% by weight was identified in sample 5907-L2 (gypsum board wall with white paint) at 0.51% lead by weight. The remaining three lead samples (metal pipe, wood window frame, and wood door) tested below regulatory thresholds. Recommendations require contractors to be informed of the absence of ACM and the presence of LBP on the white gypsum board wall surface. The report notes that OSHA 29 CFR 1926.62 regulations apply, and contractors must implement appropriate personal protective measures. The survey's scope was limited to sampled materials only, with no warranty provided for unsampled areas, inaccessible spaces, or materials hidden behind walls or flooring.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Building 5907, JBSA-CB 2

The asbestos and lead-based paint survey was performed on 15 May 2013 by Bonnie L.

Lee, Texas DSHS Asbestos Inspector License #602834 and Texas DSHS Lead Inspector

License #2060868.

Bulk Samples:

Asbestos

Nine samples were collected from inside Building 5907.

The following homogenous areas were identified and bulk samples collected:

Homogenous

Area

Description

Sample IDs

1 Wall Texture CB5907-H1ABC

2 Gypsum Board CB5907-H2ABC

3 Joint Compound CB5907-H3ABC

Lead

Four samples were collected from inside Building 5907.

The following building painted surfaces were identified as potentially containing LBP and sampled:

Sample ID Description

5907-L1 Metal Pipe – Cream, Green, Yellow

5907-L2 Gypsum Board Wall – White

5907-L3 Wood Window Frame – White, Green

5907-L4 Wood Door – Brown, Gray

Conclusions:

Asbestos was not detected in any sample layer.

Building 5907, JBSA-CB 3

Greater than the EPA’s minimum regulatory level of 0.5% by weight (wt.) was identified by laboratory analysis in the following sample:

Sample ID Description/Location Percent (%) Lead by Weight (wt.)

5907-L2 Gypsum Board Wall - White 0.51%

Lead-based paint was not detected in any of the remaining samples.

Recommendations:

Pursuant to the JBSA FSH and CB Asbestos Operations and Management Plan, inform contractors involved with any construction, demolition, renovation or related activities that

ACM was not identified.

Pursuant to the JBSA FSH and CB LBP Operations and Management Plan, inform contractors involved with any construction, demolition, renovation or related activities that white lead-based paint was identified on the gypsum board wall and any additional building components with the same color. Contractors must ensure appropriate personal protective measures to adequately protect workers and any building occupants, where present.

Regulations from the Occupational Safety and Health Act (OSHA) 29 CFR 1926.62 apply.

If materials are to be disposed of, then additional testing may be required using the Toxicity

Characteristic Leaching Procedure (TCLP) for waste characterization.

Due to the limited nature of this survey, Argus Environmental Consultants, LLC does not warrant the existence or non-existence of ACM or LBP in areas not sampled. For example, destructive sampling, evaluation in any inaccessible areas, or any areas of the building outside the proposed evaluation has not been done. Therefore, any suspect materials hidden in or behind walls, under the flooring or other inaccessible areas are not included in this report. Argus Environmental Consultants, LLC only warrants the existence or non-existence of asbestos and LBP in those materials actually sampled.

During all future renovation, demolition or construction activities, any material(s) suspected to contain asbestos or lead that has not been previously sampled should be evaluated and bulk samples collected for appropriate laboratory analysis prior to disturbance/removal.

This report has been prepared for the exclusive use of Weston Solutions, Inc. and JBSA-

CB and their assigned agents. It and all contents, findings, conclusions and

EMSL Analytical, Inc.

8700 Jameel Road, Suite 190, Houston, TX 77040 Phone/Fax: (713) 686-3635 / (713) 686-3645 http://www.emsl.com houstonlab@emsl.com

151302277

CustomerID: WESO30

CustomerPO:

ProjectID: JBSA-FSH Texas

EMSL Order:

Attn: Owena Yang-Totorica Weston Solutions 70 NE Loop 410 Suite 600 San Antonio, TX 78216-5842

Received: 05/16/13 8:50 AM

Weston (JBSA-CB - Bldg. 5907) Job # 12832.002.129.0005

Fax:

Phone:

Project:

5/30/2013Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

CB5907-H1A

151302277-0001

Latrine - Wall

Texture

White/Beige None Detected

Inseparable paint / coating layer included in analysis

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

CB5907-H1B

151302277-0002

Latrine - Wall

Texture

White/Beige None Detected

Inseparable paint / coating layer included in analysis

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

CB5907-H1C

151302277-0003

Latrine - Wall

Texture

White/Beige None Detected

Inseparable paint / coating layer included in analysis

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

CB5907-H2A

151302277-0004

Latrine - Gypsum

Board

Brown/White None Detected Fibrous

Homogeneous

Cellulose10% Non-fibrous (other)90%

CB5907-H2B

151302277-0005

Latrine - Gypsum

Board

Brown/White None Detected Fibrous

Homogeneous

Cellulose10% Non-fibrous (other)90%

CB5907-H2C

151302277-0006

Latrine - Gypsum Board

White None Detected Fibrous

Homogeneous

Cellulose10% Non-fibrous (other)90%

CB5907-H3A

151302277-0007

Latrine - Joint

Compound

White None Detected Non-Fibrous

Homogeneous

Non-fibrous (other)100%

1Test Report PLM-7.28.7 Printed: 5/30/2013 5:38:42 PM

Michelle Leggett, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. Houston, TX NVLAP Lab Code 102106-0, AZ 0925, CO AL-15355, LA 04126, TX 300159

Initial report from 05/30/2013 15:47:00

Jenny Drapela (3) Jason Mote (6) http://www.emsl.com mailto:houstonlab@emsl.com

EMSL Analytical, Inc.

8700 Jameel Road, Suite 190, Houston, TX 77040 Phone/Fax: (713) 686-3635 / (713) 686-3645 http://www.emsl.com houstonlab@emsl.com

151302277

CustomerID: WESO30

CustomerPO:

ProjectID: JBSA-FSH Texas

EMSL Order:

Attn: Owena Yang-Totorica Weston Solutions 70 NE Loop 410 Suite 600 San Antonio, TX 78216-5842

Received: 05/16/13 8:50 AM

Weston (JBSA-CB - Bldg. 5907) Job # 12832.002.129.0005

Fax:

Phone:

Project:

5/30/2013Analysis Date:

Collected:

Sample Description Appearance % Type

AsbestosNon-Asbestos

% Fibrous % Non-Fibrous

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 and/or EPA 600/M4-82-020 Method(s) using Polarized Light Microscopy

CB5907-H3B

151302277-0008

Latrine - Joint

Compound

White None Detected Non-Fibrous

Homogeneous

Non-fibrous (other)100%

CB5907-H3C

151302277-0009

Latrine - Joint

Compound

White None Detected

Inseparable paint / coating layer included in analysis

Non-Fibrous

Heterogeneous

Non-fibrous (other)100%

2THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.28.7 Printed: 5/30/2013 5:38:42 PM

Michelle Leggett, Laboratory Manager or other approved signatory

Analyst(s)

EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Reporting limit is 1%

Samples analyzed by EMSL Analytical, Inc. Houston, TX NVLAP Lab Code 102106-0, AZ 0925, CO AL-15355, LA 04126, TX 300159

Initial report from 05/30/2013 15:47:00

Jenny Drapela (3) Jason Mote (6) mailto:houstonlab@emsl.com

Client Sample Description ConcentrationLab ID Analyzed

Collected

EMSL Analytical, Inc.

200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.emsl.com cinnaminsonleadlab@emsl.com

Attn: Aimee Kambhu Weston Solutions 70 NE Loop 410 Suite 600 San Antonio, TX 78216-5842

Received: 05/16/13 9:37 AM

WESTON (JBSA-CB-Bldg.5907)

Fax:

Phone:

Project:

5/15/2013Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B*/7000B)

201305108

CustomerID: WESO30

CustomerPO:

ProjectID: JBSA-FSH Texas

EMSL Order:

Site: Metal Pipe Desc: Cream/Green/Yellow

00015907-L1 0.11 % wt5/28/20135/15/2013

Site: Gypsum Board Wall Desc: White

00025907-L2 0.51 % wt5/28/20135/15/2013

Site: Wood Window Frame Desc: White/green

00035907-L3 0.015 % wt5/28/20135/15/2013

Site: Wood Door Desc: Brown/Grey

00045907-L4 0.18 % wt5/28/20135/15/2013

Julie Smith - Laboratory Director NJ-NELAP Accredited:03036 or other approved signatory

Test Report ChmSnglePrm/nQC-7.21.0 Printed: 5/29/2013 1:51:12 PM

Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. The QC data associated with these results included in this report meet the method QC requirements, unless specifically indicated otherwise. Unless noted, results in this report are not blank corrected. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted.

* slight modifications to methods applied. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request.

Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01

Initial report from 05/29/2013 13:39:50 mailto:cinnaminsonleadlab@emsl.com

Building 5907 - Bulk Sample Diagram

L-2

L-1

L-3

L-4

H1C

H3AB

H2AB

H1AB

H3C

H2C

Legend

Green - Non-Asbestos Sample Locations

Blue - Non-Lead Sample Locations

Purple - Lead Sample Locations

Date: _10/6/14_

10004 Wurzbach Road, Ste. 247 San Antonio, Texas 78230

Consultants, LLCEnvironmental

Building 5907, JBSA-CB 1

CAMP BULLIS BUILDING 5907

PHOTOGRAPHS

LBP

Gypsum Board Wall - White

(0.51% wt. Lead)

Lead-Based Paint – LBP

Weight – wt.

Binder1.pdf
CB 5907 - Asbestos and Lead Based Paint Survey.pdf
5907
CB 5907 - Asbestos and Lead Based Paint Survey
5907
CB 5907 - Asbestos COC.pdf
CB 5907 - Asbestos Results.pdf
CB 5907 - Bulk Sample Diagram.pdf
CB 5907- Photo Report.pdf
CB 5907 - Lead Results.pdf
CB 5907 - Asbestos and Lead Based Paint Survey.pdf
5907
CB 5907 - Asbestos and Lead Based Paint Survey
5907
CB 5907 - Lead COC.pdf
CB 5907- Photo Report.pdf

File details come from the government source that posted it. Updated .