Atch 4_19990511_LBP_B886_ExtSurvey.pdf
PDF 138 KB Posted
- Solicitation number
- FA461025Q0010
About this file
This is a lead-based paint survey report from Acacia Environmental Management dated May 11, 1999, regarding Building 886 at Vandenberg AFB. The survey analyzed seven paint samples collected from the building's exterior on May 7, 1999.
Of the samples tested, five showed no detectable lead content (samples -01, -02, -03, -06, and -07). Sample -05 contained lead in the range of 50-999 mg/kg, requiring TCLP and Cal. W.E.T. protocol analysis before disposal. Sample -04 contained 2,330 mg/kg lead (0.23%), automatically classifying it as hazardous waste under RCRA and California state regulations. The report includes a building sketch showing sample locations and laboratory analysis reports from Micro Analytical Laboratories detailing the test results. Per OSHA regulations (29 CFR 1926.62), employers must protect workers from lead exposure when any detectable amount is present.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Acacia Environmental Management 511 North H Street, Suite H • LomfX?C, CA 93436 • (805) 735-1958 • (805) 735-4378 fax
May 11, 1999
Mr. E. Crosby
30 CES/CEEOHV
1172 Iceland Ave.
Bldg. 11439, Room 143 Vandenberg AFB, CA 93437
RE: LEAD-BASED PAINT SURVEY -BUILDING 886
Dear Mr. Crosby:
Acacia Environmental Management performed a survey of the exterior of the referenced facility on May 7, 1999 and a copy of the analytical report is attached for your reference and archiving.
Of the seven (7) paint samples collected and analyzed, five samples (I.D. No. -01, -02, -03, -06, and -07) no detectable amount of lead was analyzed to be present.
One sample (I.D. No. -05) was found to contain lead in the range of 50 to 999 mg/kg, and residual debris will need to subsequently be analyzed by TCLP and Cal. W.E.T. protocol to characterize the waste prior to disposal.
Sample No. -04 was analyzed to contain 1,000 or greater mg/kg lead, and residual waste automatically is characterized as "hazardous waste" by RCRA and the State of California.
OSHA regulations (29 CFR 1926.62) require an employer to protect his/ her employees form over exposure to lead, whenever a detectable amount of lead is analyzed to be present.
Sincerely, u'-- Dan Weathers, President
Attachment: Analytical Report and Sketch Code: 9981
L t -07
I Building &86
-06;f
-05 -04
-01
-02
'-03
Acacia Environmental Man~ement May 7, 1999
Con!jultant ~· No. 100
P•ge
MICRO ANALYTICAL LABORATORIES, INC.
FLAME AA - LEAD IN PAINT - EPA SOP (1991)
Acacia Environmental Management 511 North "H" Street, Suite H Lompoc, CA 93436
Sample ID rciient l_ __ , __ ...... ue-01 Lnb: 68621·01 TAN/ FACI,t,l TliiM
C~ent: L_ ___ .. ! 1111·0:1
L;1b: OS621·02 BI:IGE I WOOD StotNC
~~nt[ 888·03 •-u•·•
L::.b: 68021-03 IIROWN/MAN DOOR lo FRAME
Client:[. 886-04 lab: 68621·04 •tiiGI/ CONCRET£ f--ent[ Client ---· eea-os -- Lab: 68621 ·05 bEIGE/METAL
Farkt
I
PROJECT:
VAFB
CONTRACT NO.
F04684-96-A0016
FACILITY: 886
Lead Concentration
Micro Log In 6 8 6 2 1 Total Sampi9S 7
Dale Sampled 51711 9 99
Dale Received 5 I 1 0/1 9 9 9
Dale Analy~:ed 5/1 0/199 9
Weight Percent rng/kg (ppm)
Oettctlon Limit
(mg/kg)
< 0.01% < 46 46
.. 0.01% < 47 47
< 0.01% < 4!5 45
0.23% 2,330 44
0.04% 351 37
Analyst: __ 'IT
AIHA El.lAP Accrodltod Labo<•tory, 10 t II 150. I 11~ by Flam& A!omlc Ab$Orplilll'l Speclromohy It~ aoc:ordence with EPA'$ 'Sial'lllard Operati11g Procedures for Lud In Plllot by /iotpl•l•- or Microwaw-ba~td Acid dlgosllons al'ld Alomic Atisorptlorl or Inductively Couplad l'lasmR Ernlss'on Sp•ctrometry' (1991), EPAie00/11·911213, NTIS Oocumonl No. Pe;2-114172. Sample& are preparod by llotph•le dlgoslion with nilric acid ond hydro~en peroxld<•, nnd •n!dyred lly Flame AA This report must not bll reproduced •~cept in lull, with the approval of fJioro Analylical laboratorit$, Inc .. ~rei pertains only to h MIT'plos anolylBd. Unit elfl)lanallont: mg "mllllgrcm&; kg • k'!ograrns; pprn = parh per million. NIA "Not Applicable.
5900 HOLLIS STREET, SUITt! M, EMERYVIllE, CALIFORNIA 84608 • (!110) !!53·0824
Pagt 2
MICRO ANALYTICAL LABORATORIES, INC,
FLAME AA - LEAD IN PAINT- EPA SOP (1991)
Acacia Environmental Management 511 North "H" Street, Suit9 H lompoc, CA 93436
Sample to Client: U8·0f5 lttb: 68621 ·06
SHOWN I MEN DOOFI & FRAME
m~~i:C: 816·07 l~tb: OS621-07 BI'IGE IOVF:RH~AD bOOR
PROJECT:
VAFB
CONTRACT NO.
F04684·96-A001 S
FACILITY: 888
Micro Log In 6 8 6 2 1
T'lal S&rr'!lles 7
Oat" S5mplod 5.'7 if 9 99
Data AeelliV!!d $/10/199 9
0911 ,4.naly~ed 511 0/1 9 9 9
Lead Concentration Deter;:tion
Limit Weight Percent mg/kg (ppm) (mg/kg)
< 0.01% < 47 47
< 0.01"' < 49 49
Analyst:--· T1'
AIHA Et-lAP Accrodilod labQratcry, 10 1111 SO. '' zod by Flame Alomlc Absorption Speclrcmotry In aocc:mlllnce with EPA's "Standurl1 Oparaling Procoduras for Laa~ In Plllnt by Hotplate- or Microwave·ba$8d Acid dlges!lons 111\d Atomic Ab,orptlon or lndu~lvely Ccuplod Plasma Emission Spetfromotry' (1~Q1), EPAJ~00/8-91/21!J, NTIS Oooumonr No. Pe9ll·1141'72. Samples are prepared by hotplate dfg"slion with nitric e~i~ and hydrcgrn pei'OlCicl~·. and analyzed by f''-me M. This 18p0rl must net be reproduced except In 1\JII, with the approval ol Micro Analyth;al leboroto~l~s. lr.e., end pert11fns only to 11'111 5llmpln anal)lred. Unlttllpla,.lions: mg • milligrams: kg" klfogl'llms; ppm; parts por million. N/A = Nol Applicable stOO HOLLIS STR!!T, SUITE M, EMERYVILLE, CALIFORNIA 94608 • (510) 653·0824