Atch 2_Draft Drawing 10 Fire Protection - Repair Dorm B542.pdf

PDF 15 MB Posted

Attached to
Project No. QKKA 171042, Repair Dorm Bldg. 542, Misawa Air Base, Japan
Solicitation number
FA520522R0001
Issued by

About this file

This pre-solicitation notice is for a firm-fixed price construction contract to renovate Dormitory Building 542 at Misawa Air Base in Japan. The contractor shall provide supervision, management, labor, equipment and materials to complete interior and exterior demolition, hazardous material abatement, structural and architectural improvements, new building systems and finishes. Scope includes electrical, plumbing and telecommunications renovations along with new fire alarm, mass notification and suppression systems. Civil site work will integrate with existing sidewalks and utilities and include a new fire vehicle access lane. Exterior utilities for HVAC will also be improved. The performance period is 531 calendar days including 30 days for mobilization. The contract value is estimated between $10-25 million USD. The solicitation will issue on January 31, 2022 with proposals due around 40 days later. A pre-proposal conference is scheduled for February 25, 2022 to review requirements. The award will be a single contract determined by subjective tradeoff of past performance and price factors. Registration in SAM is required and the contractor must be authorized to operate in Japan.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

01 02 03 04 05 06 07 08 09 11 12 13 14 14'10

STAIR 2

STAIR 1

UNIT 124STORAGE 1

UNIT 119 UNIT 121 UNIT 123

LAUNDRY 1

JANITOR 1

CORRIDOR 1W

DAY ROOM 1

MECHANICAL RM

LINEN 1

UNIT 114UNIT 112UNIT 110UNIT 108

UNIT 113UNIT 111UNIT 109UNIT 107UNIT 105UNIT 103UNIT 101

UNIT 102 UNIT 104 UNIT 106

RRM 1

LOBBY

CORRIDOR 1

OFFICE

M

ATC

H

LIN

E M

ATC

H

LIN

E

EXISTING PIPING IN

BELOW FLOOR

UTILIDOR

2 2

DEMOLISH EXISTING FIRE

ALARM AND SUPPRESSION

SYSTEMS COMPLETE

WITHIN THIS BOUNDARY

FA

S

FAS FAS

S S

S S

S S

S S

S S

S S

S

S

S

S SS

HH

H

H

HH

HH

H

S S S S

DH

DH

DH

DH

DH

DH

PB

H H

S FC

P

FTR

FC

P

FPC FPC

FE

FE

FA

S

65 50

FIRE PROTECTION LEGEND - DEMOLITION

SPRINKLER / STANDPIPE RISER

FIRE DEPARTMENT CONNECTION

STANDPIPE HOSE VALVE

ELECTRIC FIRE PUMP

PIPING / EQUIPMENT TO BE DEMOLISHED

PIPE TURNED DOWN

PIPE TURNED UP

FAS FIRE ALARM STATION, JAPANESE STYLE

(PUSH STATION, ALARM BELL, LOCATION LAMP)

SMOKE DETECTORS

H HEAT DETECTOR

FIRE ALARM BELL

DOOR HOLD OPEN DEVICEDH

PUSH BUTTON MANUAL STATIONPB

UNINTERRUPTIBLE POWER SUPPLY

FIRE ALARM CONTROL PANEL

FIRE ALARM TRANSMITTER

FCP

FTR

FIRE PUMP CONTROLLERFPC

FE FIRE EXTINGUISHER

BIG VOICE LOUDSPEAKER (EXISTING TO REMAIN)

BIG VOICE CONTROLLERS (EXISTING TO REMAIN)

FA TRANSMITTER ANTENNA

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

STAIR 3

UNIT 130UNIT 128UNIT 126 UNIT 136

UNIT 135

UNIT 134

UNIT 133UNIT 125 UNIT 127 UNIT 129

UNIT 132

UNIT 131

CORRIDOR 1E

M

ATC

H

LIN

E

DEMOLISH EXISTING FIRE

ALARM AND SUPPRESSION

SYSTEMS COMPLETE

WITHIN THIS BOUNDARY

FASFAS

S S

S S

S S

S S

S S

S S

S

DH

DH

FE

A

B

C

D

E

F

S.

LE

O

PO

LD

SV

L

SW

D

FD101

FI

R

E

PR

O

TE

C

TI

O N

D

EM

O

LI

TI

O

N P

LA

N

FI

R

ST

F

LO

O R

KEYNOTES

1 DEMOLISH ELECTRIC FIRE PUMP, INCLUDING ALL PIPING,

CONTROLLERS, POWER, WIRING, AND ALL RELATED

APPURTENANCES. DRAIN AND CLEAN EXISTING BELOW

FLOOR WATER SUMP, FILL WITH SAND, AND ABANDON IN

PLACE.

GENERAL DEMOLITION NOTES:

1. FIRE PROTECTION DEMOLITION DRAWINGS ARE BASED

ON EXISTING AVAILABLE AS-BUILT DRAWINGS AND

FIELD OBSERVATIONS. CONTRACTOR SHALL VERIFY

EXISTING CONDITIONS PRIOR TO STARTING

CONSTRUCTION. ANY DISCREPANCIES SHALL BE

BROUGHT TO THE ATTENTION OF THE CONTRACTING

OFFICER PRIOR TO CONSTRUCTION.

2. DEMOLISH EXISTING FIRE ALARM, FIRE SPRINKLER,

AND STANDPIPE SYSTEMS COMPLETE, INCLUDING ALL

DEVICES, COMPONENTS, PANELS, WIRING, CONDUIT,

PIPING, VALVES, EQUIPMENT, ETC.

3. DEMOLISH UPS IN FIRE ALARM CONTROL ROOM. UPS IS

DEDICATED TO AND IS PART OF EXISTING FIRE ALARM

SYSTEM.

4. DEMOLISH ALL PORTABLE FIRE EXTINGUISHERS,

INCLUDING ALL MOUNTING BRACKETS AND EQUIPMENT.

5. DRAWINGS INDICATE GENERAL QUANTITY, LOCATION,

AND TYPES OF DEVICES AND COMPONENTS TO BE

DEMOLISHED. HOWEVER, ANY ADDITIONAL DEVICES

AND COMPONENTS FOUND TO BE EXISTING BUT NOT

SHOWN ON THE DRAWINGS SHALL BE INCLUDED IN THE

DEMOLITION.

6. ALL EXISTING FIRE ALARM CIRCUITS ARE ASSUMED TO

BE CLASS A.

7. PATCH ALL PENETRATIONS THAT WILL NOT BE REUSED

FOR NEW SYSTEMS OR EQUIPMENT.

FIRE PROTECTION DEMOLITION PLAN - FIRST FLOOR

SCALE: 1:100 0 1000 3000 7000

BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO

REMAIN.

PLAN

NORTH

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

3 DEMOLISH EXISTING FIRE DEPARTMENT CONNECTION,

100mm STANDPIPE, HOSE VALVE, AND ALL

APPURTENANCES. PATCH WALL PENETRATION TO MATCH

EXISTING ADJACENT SURFACES.DRAFT

STAIR 1

UNIT 223UNIT 221

UNIT 224UNIT 222

UNIT 219

UNIT 218

STORAGE 2

CORRIDOR 2W

LOUNGE 2

LAUNDRY 2

UNIT 216UNIT 214UNIT 212UNIT 210UNIT 208UNIT 206UNIT 204UNIT 202

UNIT 201 UNIT 203 UNIT 205 UNIT 207 UNIT 209 UNIT 211 UNIT 213

JANITOR 2

CORRIDOR 2

M

ATC

H

LIN

E M

ATC

H

LIN

E

2 2

DEMOLISH EXISTING FIRE

ALARM AND SUPPRESSION

SYSTEMS COMPLETE

WITHIN THIS BOUNDARY

FAS FAS

S S

S S

S S

S S

S S

S S

S

S

S

S SS

S S S S

DH

DH

DH

DH

DH

DH

H

S

H

H

S S

H

H

FEFE

FE

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

STAIR 3

UNIT 233UNIT 231UNIT 229UNIT 227UNIT 225

UNIT 232UNIT 230UNIT 228UNIT 226 UNIT 236UNIT 234

UNIT 235

CORRIDOR 2E

M

ATC

H

LIN

E

DEMOLISH EXISTING FIRE

ALARM AND SUPPRESSION

SYSTEMS COMPLETE

WITHIN THIS BOUNDARY

FASFAS

S S

S S

S S

S S

S S

S S

S

DH

DH

FE

A

B

C

D

E

F

S.

LE

O

PO

LD

SV

L

SW

D

FD102

FI

R

E

PR

O

TE

C

TI

O N

D

EM

O

LI

TI

O

N P

LA

N

SE

C O

N D

F

LO

O R

FIRE PROTECTION DEMOLITION PLAN - SECOND FLOOR

SCALE: 1:100 0 1000 3000 7000

KEYNOTES

1 DEMOLISH COMMERCIAL KITCHEN HOOD AND INTEGRAL

WET CHEMICAL FIRE SUPPRESSION SYSTEM, INCLUDING

ALL PIPING, COMPONENTS AND CONTROLS.

2 BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO

REMAIN.

PLAN

NORTH

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

3 DEMOLISH EXISTING 100mm STANDPIPE, HOSE VALVE, AND

ALL APPURTENANCES. EXISTING FLOOR PENETRATION TO

REMAIN.

DRAFT

STAIR 1

UNIT 318

UNIT 319 UNIT 321 UNIT 323

UNIT 324UNIT 322

LOUNGE 3 STORAGE 3

CORRIDOR 3W

LAUNDRY 3UNIT 316UNIT 314UNIT 312UNIT 310UNIT 308UNIT 306UNIT 304UNIT 302

UNIT 301 UNIT 303 UNIT 305 UNIT 307 UNIT 309 UNIT 311 UNIT 313

JANITOR 3

CORRIDOR 3

M

ATC

H

LIN

E M

ATC

H

LIN

E

2 2

DEMOLISH EXISTING FIRE

ALARM AND SUPPRESSION

SYSTEMS COMPLETE

WITHIN THIS BOUNDARY

FAS FAS

S S

S S

S S

S S

S S

S S

S

S

S

S SS

S S S S

DH

DH

DH

DH

DH

DH

H

S

H

H

S S

H

H

FEFE

FE

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

STAIR 3

UNIT 333

UNIT 332UNIT 330

UNIT 331UNIT 325 UNIT 327 UNIT 329

UNIT 328UNIT 326 UNIT 334

UNIT 335

UNIT 336

CORRIDOR 3E

M

ATC

H

LIN

E

DEMOLISH EXISTING FIRE

ALARM AND SUPPRESSION

SYSTEMS COMPLETE

WITHIN THIS BOUNDARY

FAS

S S

S S

S S

S S

S S

S S

S

DH

DH

FAS FE

A

B

C

D

E

F

S.

LE

O

PO

LD

SV

L

SW

D

FD103

FI

R

E

PR

O

TE

C

TI

O N

D

EM

O

LI

TI

O

N P

LA

N

TH

IR

D

F

LO

O R

FIRE PROTECTION DEMOLITION PLAN - THIRD FLOOR

SCALE: 1:100 0 1000 3000 7000

KEYNOTES

1 DEMOLISH COMMERCIAL KITCHEN HOOD AND INTEGRAL

WET CHEMICAL FIRE SUPPRESSION SYSTEM, INCLUDING

ALL PIPING, COMPONENTS AND CONTROLS.

2 BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO

REMAIN.

PLAN

NORTH

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

3 DEMOLISH EXISTING 100mm STANDPIPE, HOSE VALVE, AND

ALL APPURTENANCES. EXISTING FLOOR PENETRATION TO

STAIR 1

DAY ROOM 4

UNIT 418

UNIT 419 UNIT 423

STORAGE 4

UNIT 422 UNIT 424UNIT 416UNIT 414UNIT 412UNIT 410UNIT 408UNIT 406UNIT 404UNIT 402

UNIT 401 UNIT 403 UNIT 405 UNIT 407 UNIT 409 UNIT 411 UNIT 413

LAUNDRY 4

JANITOR 4

UNIT 421

CORRIDOR 4CORRIDOR 4W

RRM 4

M

ATC

H

LIN

E M

ATC

H

LIN

E

FAS FAS

S S

S S

S S

S S

S S

S S

S

S

S

S SS

S S S S

DH

DH

DH

DH

DH

DH

S

H

H

S S

H

H

FE

FE

DEMOLISH EXISTING FIRE

ALARM AND SUPPRESSION

SYSTEMS COMPLETE

WITHIN THIS BOUNDARY

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

STAIR 3

UNIT 425

UNIT 434UNIT 426 UNIT 428 UNIT 430 UNIT 432

UNIT 427 UNIT 429 UNIT 431 UNIT 433 UNIT 435

CORRIDOR 4E

UNIT 436

M

ATC

H

LIN

E

FAS

S S

S S

S S

S S

S S

S S

S

DH

DH

FAS FE

DEMOLISH EXISTING FIRE

ALARM AND SUPPRESSION

SYSTEMS COMPLETE

WITHIN THIS BOUNDARY

A

B

C

D

E

F

S.

LE

O

PO

LD

SV

L

SW

D

FD104

FI

R

E

PR

O

TE

C

TI

O N

D

EM

O

LI

TI

O

N P

LA

N

FO

U R

TH

F

LO

O

R

FIRE PROTECTION DEMOLITION PLAN - FOURTH FLOOR

SCALE: 1:100 0 1000 3000 7000

KEYNOTES

BIG VOICE SYSTEM CONTROL EQUIPMENT IS EXISTING TO

REMAIN.

2 BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO

REMAIN.

3 DEMOLISH EXISTING FIRE ALARM TRANSMITTER ANTENNA

AND ALL ASSOCIATED WIRING, SUPPORTS AND

APPURTENANCES.

PLAN

NORTH

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

4 DEMOLISH EXISTING 100mm STANDPIPE, HOSE VALVE, AND

ALL APPURTENANCES. EXISTING FLOOR PENETRATION TO

FIRE ALARM LEGEND

FIRE ALARM ANNUNCIATOR

FIRE ALARM / MASS NOTIFICATION TRANSMITTERFTR

FAA

FIRE ALARM / MASS NOTIFICATION SYSTEM CONTROL PANELFMCP

LOCAL OPERATING CONSOLELOC

H BIG VOICE LOUDSPEAKER (EXISTING TO REMAIN)

BIG VOICE CONTROLLERS (EXISTING TO REMAIN)CPBV

S SPOT TYPE SMOKE DETECTOR

S SPOT TYPE SMOKE DETECTOR W/SOUNDER BASESB

MANUAL FIRE ALARM STATIONF

DOOR HOLD OPEN DEVICEDH

WATERFLOW ALARM BELL, WEATHER PROOF DEVICE

SPEAKER / STROBE (##=CANDELA)

SPEAKER

ET VISUAL TEXT DISPLAY SIGN

SPRINKLER WATERFLOW SWITCH

SPRINKLER VALVE SUPERVISORY SWITCH

WF

VS

SPEAKER, WEATHER PROOF DEVICE

WP

FIRE ALARM TERMINAL CABINET

FA / MNS TRANSMITTER ANTENNA

FATC

LINE ISOLATION MODULE

ADDRESSABLE INPUT MODULE

ADDRESSABLE OUTPUT MODULE

WP

TEXT SIGN CONTROLLERTSC

K KEY SAFE (KNOX BOX)

FIRE ALARM GENERAL NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

2. ALL NEW FIRE PROTECTION DEVICES, COMPONENTS, AND EQUIPMENT SHALL BE LISTED AND APPROVED FOR USE

IN AUTOMATIC FIRE PROTECTION SYSTEMS.

3. ALL NEW CONDUIT, COMPONENTS AND EQUIPMENT SHALL BE LABELED AND PAINTED IN ACCORDANCE WITH THE

SPECIFICATIONS.

4. COORDINATE WITH STRUCTURAL PRIOR TO CORE DRILLING ANY WALL OR STRUCTURAL ELEMENT.

5. PROVIDE COMBINED ADDRESSABLE FIRE ALARM / MASS NOTIFICATION SYSTEM THROUGHOUT ENTIRE BUILDING IN

ACCORDANCE WITH UFC 3-600-01 (10 MAY 2019), 4-021-01 (01 JAN 2010), NFPA 72 (2019), AND PROJECT

SPECIFICATIONS.

6. DRAWINGS ARE CONCEPTUAL IN NATURE AND INDICATE DESIGN INTENT AND APPROXIMATE DEVICE LOCATIONS.

CONTRACTOR SHALL COORDINATE WITH OTHER TRADES AND CEILING MOUNTED DEVICES AND EQUIPMENT AND PROVIDE ALL NECESSARY DEVICES AND COMPONENTS FOR FULLY FUNCTIONAL CODE COMPLIANT SYSTEM. FINAL DEVICE QUANTITIES, LOCATIONS, CANDELA RATINGS, ETC. SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 72

AND SHALL BE SHOWN ON CONTRACTOR SHOP DRAWINGS.

7. ALL INITIATING, NOTIFICATION, AND SIGNALING LINE CIRCUITS SHALL BE CLASS B. SLC LOOPS SHALL BE

PERMITTED PER NFPA 72.

8. PROVIDE SPEAKER LAYOUT TO ENSURE THE AUDIBILITY AND INTELLIGIBILITY REQUIREMENTS OF UFC 4-021-01 AND NFPA 72 ARE MET. PROVIDE MINIMUM CIS LEVEL OF 0.80 IN NORMALLY OCCUPIED SPACES. AREAS OF THE BUILDING NOT NORMALLY EXPECTED TO BE OCCUPIED (STORAGE AND EQUIPMENT ROOMS) MAY HAVE A LOWER CIS SCORE IF PERSONNEL CAN DETERMINE THAT A VOICE MESSAGE IS BEING BROADCAST AND MAY WALK NO MORE THAN 15.3 M (50 FT.) TO A LOCATION WITH AT LEAST A 0.80 CIS. PROVIDE AUDIBILITY AND INTELLIGIBILITY

ANALYSIS CALCULATIONS IN ACCORDANCE WITH SPECIFICATIONS.

9. PROVIDE FIRE ALARM ANNUNCIATOR PANEL WITH LCD DISPLAY. PROVIDE PRINTED AND FRAMED BUILDING FLOOR PLAN ON WALL ADJACENT TO ANNUNCIATOR PANEL. FLOOR PLAN SHALL INDICATE ALL ROOMS AND FIRE ALARM DEVICES TO FACILITATE PHYSICAL LOCATION BASED UPON THE LCD DISPLAY INFORMATION FOR EACH DEVICE.

10. PROVIDE WORKING PLANS AND CALCULATIONS PREPARED BY OR UNDER THE DIRECT SUPERVISION OF A REGISTERED FIRE PROTECTION ENGINEER OR AN INDIVIDUAL WHO HAS OBTAINED LEVEL III CERTIFICATION FROM THE NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES (NICET), FIRE ALARM SYSTEMS SUBFIELD. DRAWINGS SHALL BE FULL SIZE DRAWINGS, MINIMUM 1:100 SCALE (1/8" = 1'-0").

11. PROVIDE A DOCUMENTATION CABINET ADJACENT TO THE FIRE ALARM CONTROL PANEL, OR OTHER LOCATION AS APPROVED BY THE CONTRACTING OFFICER, WITH FIRE ALARM AND FIRE SUPPRESSION SYSTEM AS-BUILT

DRAWINGS, O&M MANUALS, AND CD/DVD WITH SOFTWARE COPIES.

12. PROVIDE SPARE PARTS CABINET ADJACENT TO THE FIRE ALARM CONTROL PANEL, OR OTHER LOCATION AS APPROVED BY THE CONTRACTING OFFICER, WITH MANUFACTURER'S RECOMMENDED SPARE PARTS.

13. PROVIDE FIRE ALARM / MASS NOTIFICATION SYSTEM CONTROL PANELS, ANNUNCIATOR PANELS, LOCAL OPERATING CONSOLES, AND OTHER EQUIPMENT COMPATIBLE WITH EXISTING BASEWIDE REPORTING SYSTEM EQUIPMENT. EXISTING FIRE ALARM REPORTING SYSTEM IS MONACO RADIO TRANSCEIVER SYSTEM.

14. PROVIDE RADIO TRANSMITTER/COMMUNICATOR AND OMNI-DIRECTIONAL ANTENNA COMPATIBLE WITH EXISTING BASEWIDE MONACO RADIO REPORTING SYSTEM. COORDINATE ANTENNA LOCATION WITH LOCAL BASE FIRE

DEPARTMENT.

15. PROVIDE SURGE SUPPRESSION AT ALL CIRCUITS, POWER SUPPLIES, ETC. ENTERING OR LEAVING THE BUILDING, EXCEPT SURGE SUPPRESSION SHALL NOT BE REQUIRED FOR DEVICES MOUNTED DIRECTLY TO THE BUILDING

EXTERIOR.

16. ALL DEVICES INSTALLED OUTDOORS OR IN SHOWER AREAS SHALL BE WEATHERPROOF AND LISTED FOR USE AT THE EXPECTED MINIMUM/MAXIMUM AMBIENT TEMPERATURE AND HUMIDITY FOR THE LOCATION. PROVIDE

SEPARATE CIRCUIT FOR ALL DEVICES INSTALLED OUTDOORS.

17. SMOKE DETECTORS SHALL NOT BE INSTALLED LESS 915MM (3 FT.) FROM ANY BATHROOM DOOR, HVAC SUPPLY OUTLET OR RETURN GRILL, UNLESS THIS WOULD PREVENT THE INSTALLATION OF ANY REQUIRED DETECTOR.

18. PROVIDE WALL MOUNTED LED TEXT DISPLAY SIGNS ABOVE (OR ADJACENT TO) EXITS WHERE SHOWN ON THE

DRAWINGS.

19. PROVIDE SMOKE DETECTOR WITH SOUNDER BASE IN ALL SLEEPING ROOMS AS SHOWN ON THE DRAWINGS.

SOUNDER SHALL BE CAPABLE OF PRODUCING A 520 HZ TEMPORAL THREE (T3) SIGNAL FOR FIRE IN ACCORDANCE

WITH UFC 3-600-01 AND NFPA 72.

20. COMPLETE PRE-FINAL TEST AND INSPECTION, TO INCLUDE CONFIRMATION OF RECEIPT OF ALL SIGNALS AT REPORTING STATION, BEFORE SUBMITTING REQUEST TO SCHEDULE FINAL TESTING. AFTER PRELIMINARY TESTS HAVE BEEN SUCCESSFULLY COMPLETED, PERFORM ALL FINAL TESTING IN ACCORDANCE WITH SPECIFICATIONS AND NFPA 72. ALL PRELIMINARY AND FINAL TESTING SHALL BE WITNESSED AND APPROVED BY THE CONTRACTOR'S QUALIFIED ENGINEER AND THE CONTRACTING OFFICER'S DESIGNATED REPRESENTATIVE.

MANUAL FIRE ALARM STATION

FIRE ALARM / MASS NOTIFICATION

SYSTEM SEQUENCE OF OPERATION

TRANSMIT FIR

E ALA

RM SIG

NAL T

O BASEWID

E

REPORTIN

G SYSTEM

TRANSMIT SUPERVISORY SIG

NAL T

O BASEWID

E

REPORTIN

G SYSTEM

TRANSMIT TROUBLE

SIG

NAL T

O BASEWID

E

REPORTIN

G SYSTEM

TRANSMIT W

ATERFLO

W ALA

RM SIG

NAL T

O

BASEWID

E R

EPORTIN

G SYSTEM

TRANSMIT M

NS O

VERRID

E SIG

NAL T

O BASEWID

E

REPORTIN

G SYSTEM (IF

ACTIVE FIR

E ALA

RM PRESENT)

AUDIO

/VISUAL F

IR

E ALA

RM IN

DIC

ATIO

N BY

ZONE/D

EVIC

E AT THE FMCP

AUDIO

/VISUAL S

UPERVISORY IN

DIC

ATIO

N BY

ZONE/D

EVIC

E AT THE FMCP

AUDIO

/VISUAL T

ROUBLE

IN

DIC

ATIO

N BY

ZONE/D

EVIC

E AT THE FMCP

ACTIVATE AUDIBLE

/TEXTUAL

NOTIFIC

ATIO

N

APPLIA

NCES AND VISIBLE

STROBES

ACTIVATE SMOKE D

ETECTOR SOUNDER BASE IN

AFFECTED D

WELL

IN

G U

NIT / S

LE

EPIN

G R

OOM

ACTIVATE EXTERIO

R W

ATERFLO

W ALA

RM

RELE

ASE D

OOR H

OLD

O

PEN D

EVIC

ES

OVERRID

E FIR

E ALA

RM AUDIBLE

/TEXTUAL M

ESSAGE W

ITH

MNS ANNOUNCEMENT (IF

ACTIVE FIR

E ALA

RM PRESENT)

REACTIVATE FIR

E ALA

RM M

ESSAGE

(IF

ACTIVE FIR

E ALA

RM PRESENT)

ALARM

SYSTEM INPUTS

SYSTEM O

UTPUTS

SPOT TYPE SMOKE DETECTOR

SPRINKLER WATERFLOW SWITCH

EXTERNAL MNS INPUT

ACTIVATE LOC, LIVE MNS ANNOUNCEMENT

ACTIVATE PRE-RECORDED MNS ANNOUNCEMENT

SPRINKLER VALVE TAMPER SWITCH

SUPERVISORY

KEY SAFE (KNOX BOX) TAMPER SWITCH

TROUBLE

LOW BATTERY VOLTAGE

AC POWER FAILURE

SUPERVISED COMPONENT FAILURE

CIRCUIT FAULT

GROUND FAULT

SPOT TYPE SMOKE DETECTOR W/ SOUNDER BASE

(DWELLING UNIT / SLEEPING ROOM)

TRANSMITTER CONTROL PANEL

1 MINUTE AFTER LAST LIVE MNS ANNOUNCEMENT, OR

10 MINUTES AFTER LAST PRE-RECORDED ANNOUNCEMENT

S.

LE

O

PO

LD

SV

L

SW

D

FA001

FI

R

E

AL

AR

M

G

EN

ER

AL

N O

TE

S

AN

D

L

EG

EN

D

S

FIRE ALARM / MASS NOTIFICATION OPERATIONS MATRIX

SCALE: NONE

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R

GDRAFT

M

ATC

H

LIN

E M

ATC

H

LIN

E

FA

A

LO

C

FT

R

FM

C

P

S

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB

S SB

S SB

S SB S SBS SB

F

F

S

DH

DH

ET ET

WF

VS

WP

WP

WP

F

D H

VS

VS

VS

WP WP

WP WP

WP WP

WP WP

WP WP

WP WP

WP

WP

WP WP WP

WPD

H

F

CORRIDOR 1

C1

FACP RM

LOBBY

RRM 1

RR1

UNIT 106

UNIT 104

UNIT 102

UNIT 101

UNIT 103

UNIT 105

UNIT 107

UNIT 109

UNIT 111

UNIT 113

UNIT 108

UNIT 110

UNIT 112

UNIT 114

LINEN 1

MECHANICAL RM

DAY ROOM 1

LG1

CORRIDOR 1W

C1W

JANITOR 1

J1

LAUNDRY 1

LD1

UNIT 123

UNIT 121

UNIT 119

STORAGE 1

ST1

UNIT 124

STAIR 1

S1

STAIR 2

S2

WP

15 15 15

S

S

S

S

S

VS

VS

K

UNIT 126

UNIT 125

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

F

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

DH

DHET

WPWP WP

WP WP

WP WP

WP WP

WP WP

WP WP

S S3

STAIR 3

UNIT 130

UNIT 128

UNIT 126

UNIT 136

UNIT 135

UNIT 134

UNIT 133

UNIT 125

UNIT 127

UNIT 129

UNIT 132

UNIT 131

C1E

CORRIDOR 1E

15 15 S

VS

A

B

C

D

E

F

S.

LE

O

PO

LD

SV

L

SW

D

FA101

FI

R

E

AL

AR

M

P

LA

N

FI

R

ST

F

LO

O

R

FIRE ALARM PLAN - FIRST FLOOR

SCALE: 1:100 0 1000 3000 7000

KEYNOTES

BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO

REMAIN.

1 1

PROVIDE WEATHERPROOF EXTERIOR WATERFLOW ALARM

BELL. BELL TO SOUND ON ANY SPRINKLER WATERFLOW.

PLAN

NORTH

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

3 STANDPIPE CONTROL VALVE AND SUPERVISORY TAMPER

SWITCH LOCATED IN UNDERFLOOR UTILIDOR.

ATC

H

LIN

E M

ATC

H

LIN

E

LO

C

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB S SB

S SB

S SB S SBS SB

FDH

DH

ET

WF

VS

S SB S SB S SB S SB

WP WP

WP WP

WP WP

WP WP

WP WP

WP WP

WP

WP WP

WP WP WP

WP WPWP D

H

ET F

CORRIDOR 2

C2

JANITOR 2

J2

UNIT 213

UNIT 211

UNIT 209

UNIT 207

UNIT 205

UNIT 203

UNIT 201

UNIT 202

UNIT 204

UNIT 206

UNIT 208

UNIT 210

UNIT 212

UNIT 214

UNIT 216

216 LAUNDRY 2

LD2

LOUNGE 2

LG2

CORRIDOR 2W

C2W

STORAGE 2

ST2

UNIT 218

UNIT 219

UNIT 222

UNIT 224

UNIT 221

UNIT 223

STAIR 1

S1

STAIR 2

S2

151515

S

FATC

D H

SS

S

S S

S

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

F

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

DH

DHET

WP WP

WP WP

WP WP

WP WP

WP WP

WP WP

S3

STAIR 3

UNIT 233

UNIT 231

UNIT 229

UNIT 227

UNIT 225

UNIT 232

UNIT 230

UNIT 228

UNIT 226

UNIT 236

UNIT 234

UNIT 235

C2E

CORRIDOR 2E

15 15 S S

A

B

C

D

E

F

S.

LE

O

PO

LD

SV

L

SW

D

FA102

FI

R

E

AL

AR

M

P

LA

N

SE

C

O N

D F

LO

O

R

KEYNOTES

FIRE ALARM PLAN - SECOND FLOOR

SCALE: 1:100 0 1000 3000 7000

BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO

REMAIN, TYPICAL EACH FLOOR.

1 1

PLAN

NORTH

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

ATC

H

LIN

E M

ATC

H

LIN

E

LO

C

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB S SB

S SB

S SB S SBS SB

FDH

DH

ET

WF

VS

S SB S SB S SB S SB

WP WP

WP WP

WP WP

WP WP

WP WP

WP WP

WP

WP WP WP WP WP

WP WP WP

D H

ET F

CORRIDOR 3

C3

JANITOR 3

J3

UNIT 313

UNIT 311

UNIT 309

UNIT 307

UNIT 305

UNIT 303

UNIT 301

UNIT 302

UNIT 304

UNIT 306

UNIT 308

UNIT 310

UNIT 312

UNIT 314

UNIT 316

316 LAUNDRY 3

LD3

CORRIDOR 3W

C3W

STORAGE 3

ST3

LOUNGE 3

LG3

UNIT 322

UNIT 324

UNIT 323

UNIT 321

UNIT 319

UNIT 318

STAIR 1

S1

STAIR 2

S2

15 15 15

S

FATC

D H

SS

S

S S

S

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

F

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

DH

DHET

WP WP

WP WP

WP WP

WP WP

WP WP

WP WP

S3

STAIR 3

UNIT 333

UNIT 332

UNIT 330

UNIT 331

UNIT 325

UNIT 327

UNIT 329

UNIT 328

UNIT 326

UNIT 334

UNIT 335

UNIT 336

C3E

CORRIDOR 3E

15 15 S S

A

B

C

D

E

F

S.

LE

O

PO

LD

SV

L

SW

D

FA103

FI

R

E

AL

AR

M

P

LA

N

TH

IR

D F

LO

O

R

KEYNOTES

FIRE ALARM PLAN - THIRD FLOOR

SCALE: 1:100 0 1000 3000 7000

BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO

REMAIN.

1 1

PLAN

NORTH

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

ATC

H

LIN

E M

ATC

H

LIN

E

LO

C

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB S SB

S SB

S SB S SBS SB

FDH

DH

ET

WF

VS

S SB S SB S SB S SB

WP WP

WP WP

WP WP

WP WP

WP WP

WP WP

WP

WP WP WP WP WP

WP WP WP

D H

ET F

S2

STAIR 2

S1

STAIR 1

LG4

DAY ROOM 4

UNIT 418

UNIT 419

UNIT 423

ST4

STORAGE 4

UNIT 422

UNIT 424

UNIT 416

UNIT 414

UNIT 412

UNIT 410

UNIT 408

UNIT 406

UNIT 404

UNIT 402

UNIT 401

UNIT 403

UNIT 405

UNIT 407

UNIT 409

UNIT 411

UNIT 413

LD4

LAUNDRY 4

J4

JANITOR 4

UNIT 421

C4

CORRIDOR 4

C4W

CORRIDOR 4W

RR4

RRM 4

15 15 15

S

FATC

D H

SS

S

S S

S

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

F

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

S SB S SB

DH

DHET

WP WP

WP WP

WP WP

WP WP

WP WP

WP WP

S3

STAIR 3

UNIT 425

UNIT 434

UNIT 426

UNIT 428

UNIT 430

UNIT 432

UNIT 427

UNIT 429

UNIT 431

UNIT 433

UNIT 435

C4E

CORRIDOR 4E

UNIT 436

15 15 S S

A

B

C

D

E

F

S.

L

EO

PO

LD

SV

L

SW

D

FA104

FI

R

E

AL

AR

M

P

LA

N

FO

U

R

TH

F

LO

O R

KEYNOTES

FIRE ALARM PLAN - FOURTH FLOOR

SCALE: 1:100 0 1000 3000 7000

BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO

REMAIN.

1 1

EXISTING BIG VOICE CONTROL EQUIPMENT TO REMAIN.3

PROVIDE NEW ROOFTOP FA / MNS TRANSMITTER ANTENNA

AND ALL REQUIRED WIRING AND SUPPORTS FOR

COMPLETELY OPERATIONAL SYSTEM. NEW ANTENNA SHALL

BE COMPATIBLE WITH EXISTING BASEWIDE MONACO RADIO

REPORTING SYSTEM. COORDINATE FINAL ANTENNA

LOCATION WITH LOCAL FIRE DEPARTMENT.

PLAN

NORTH

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

NOTES:

1 ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED OTHERWISE.

2 IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR AUDIO

DEVICES WHILE LEAVING A MINIMUM OF 150 MILLIMETERS BETWEEN THE

CEILING AND THE TOP OF THE AUDIO DEVICE, THE DEVICE SHALL BE MOUNTED

AT 150 MILLIMETERS BELOW CEILING MEASURED TO THE TOP OF THE DEVICE.

3 IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR VISUAL

OR AUDIO/VISUAL DEVICE, THE DEVICE SHALL BE MOUNTED NOT MORE THAN

150 MILLIMETERS BELOW CEILING MEASURED TO THE TOP OF THE DEVICE.

AUDIO DEVICE

M

IN

FLOOR

CEILING

M

IN

VISUAL OR

AUDIO/VISUAL DEVICE

MANUAL ALARM

PULL STATION

M

IN

M

AX

1500 MAX.

M

IN

M

AX

CEILING

W

AL

L

M

AX

SMOKE DETECTOR ACCEPTABLE

ANYWHERE ON CEILING

TOP OF SMOKE DETECTOR ACCEPTABLE

ON WALL WITHIN 300 mm OF CEILING

TOP OF SMOKE DETECTOR NOT ACCEPTABLE

MORE THAN 300 mm BELOW CEILING

NOTES:

1 ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED OTHERWISE.

M

IN

IM

U

M

M

IN

IM

U

M

M

IN

IM

U M

FA / MNS TRANSMITTER

ANTENNA

ANTENNA MAST

ROOF

WALL MOUNTED MAST

SUPPORT BRACKET

ARRESTOR (SEE INSET)

21 mm (3/4") CONDUIT

FA / MNS TRANSCEIVER

WEATHER PROOF J-BOX W/COVER;

PROVIDE GROMMETED RUBBER BUSHING

FOR CABLE ENTRANCE TO J-BOX.

TO ANTENNA

ARRESTOR

TO BUILDING GROUND

FROM FA / MNS TRANSCEIVER

ARRESTOR (SEE INSET)

FMCP

FIRE ALARM TRANSCEIVER MAIN SERVICE

OR SUB-PANEL

21 mm (3/4") EMT W/COAX

16 mm (1/2") EMT W/#10 COPPER

BUILDING GROUND, SEE NOTE 2

NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED OTHERWISE.

2. AVOID SHARP BENDS IN BOTH COAX CABLE AND GROUND CONDUCTOR.

3. GROUND PER NFPA 70, ARTICLE 810.

MNS TRANSCEIVER

S.

L

EO

PO

LD

SV

L

SW

D

FA501

FI

R

E

AL

AR

M

D

ET

AI

LS

TYPICAL FIRE ALARM DEVICE MOUNTING DETAIL

SCALE: NONE

TYPICAL FIRE ALARM DETECTOR MOUNTING DETAIL

SCALE: NONE

FIRE ALARM TRANSMTTER ANTENNA DETAIL

SCALE: NONE 202

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

BATTERY

FTR FMCP

GROUND

ANTENNA

LOC

FAA

S SB

TO 120V

POWER

U N

IT

ET

S F

DH

COAXIAL LIGHTNING

ARRESTOR

ET

F

ST

AI

R

-1

VS WF

LA

U

N D

R Y

LD

F

DH

DH

VSVSVS

TO 2ND FLOOR LOC

S

FA

C

P R

M

LO

BB

Y

WP

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

ST

AI

R

-1

WP

S

C O

R R

ID

O

R C

1E

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

M

EC

H R

O O

M

DH

C O

R R

ID

O

R C

ST

O

R

AG

E

ST

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

DH DH

ST

AI

R

-1

WP

ET

FS

C O

R R

ID

O

R C

1W

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

D

AY

R O

O M

L G

15 15 15

1530151575

TO 2ND FLOOR

TERMINAL CABINET

2ND FLOOR

LOC

S SB

U N

IT

ET

F

DH

ET

ST

AI

R

-2

VS WF

F

DH

DH

TO 3RD FLOOR LOC

S

ST

O

R

AG

E

ST

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

ST

AI

R

-2

S S

C O

R R

ID

O

R C

2E

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

C O

R R

ID

O

R C

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

WP

S SB

U N

IT

WP

S SB

DH DH

ST

AI

R

-2

ET

FS

C O

R R

ID

O

R C

2W

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

U N

IT

WP

S SB

LO

U

N G

E

LG

15 15

15151575

TO 3RD FLOOR

TERMINAL CABINET

TO 1ST FLOOR LOC

TO FMCP

TERMINAL CABINET

S SB

U N

IT

WP 30

DH

LA

U

N D

R Y

LD

U N

IT

U N

IT

WP

S SB

U N

IT

WP

S SB

WP

F

SSS S

C O

R R

ID

O

R C

1E

S

TO 2ND FLOOR

VS

VSVS

TO 1ST FLOOR

TO 3RD FLOOR

S

S SS

S

TO WATERFLOW BELL

TSC

WP

S.

L

EO

PO

LD

SV

L

SW

D

FA601

FI

R

E

AL

AR

M

R

IS

ER

D

IA

G

R

AM

FL

O O

R S

1&

FIRE ALARM RISER DIAGRAM - FLOORS 1&2

SCALE: NONE 203

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

U N

IT

ST

AI

R

-4

ST

O

R

AG

E

ST

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

ST

AI

R

-4

C O

R R

ID

O

R C

4E

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

C

O R

R

ID

O R

C

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

ST

AI

R

-4

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

D

AY

R O

O M

L G

TO 3RD FLOOR LOC

TO 3RD FLOOR

TERMINAL CABINET

U N

IT

LA

U

N D

R Y

LD

U N

IT

U N

IT

U N

IT

C O

R R

ID

O

R C

4W

4TH FLOOR

LOC

S SB

ET

F

DH

ET

VS WF

F

DH

DH

S

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S S S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

DH DH

ET

FS

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

15 15

15151575

TERMINAL CABINET

S SB

WP 30

DH

WP

S SB

WP

S SB

TO 3RD FLOOR

S

S SS

S

3RD FLOOR

U N

IT

ST

AI

R

-3

TO 4TH FLOOR LOC

ST

O

R

AG

E

ST

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

ST

AI

R

-3

C O

R R

ID

O

R C

3E

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

C

O R

R

ID

O R

C

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

ST

AI

R

-3

C O

R R

ID

O

R C

3W

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

U N

IT

LO

U

N G

E

LG

TO 4TH FLOOR

TERMINAL CABINET

TO 2ND FLOOR LOC

TO 2ND FLOOR

TERMINAL CABINET

U N

IT

LA

U

N D

R Y

LD

U N

IT

U N

IT

U N

IT

LOC

S SB

ET

F

DH

ET

VS WF

F

DH

DH

S

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S S S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

DH DH

ET

FS

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

WP

S SB

15 15

15151575

TERMINAL CABINET

S SB

WP 30

DH

WP

S SB

WP

S SB

TO 2ND FLOOR

TO 4TH FLOOR

S

S SS

S

S.

L

EO

PO

LD

SV

L

SW

D

FA602

FI

R

E

AL

AR

M

R

IS

ER

D

IA

G

R

AM

FL

O O

R S

3&

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

FIRE ALARM RISER DIAGRAM - FLOORS 3&4

SCALE: NONE

FIRE SUPPRESSION LEGEND

RESIDENTIAL OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

ORDINARY HAZARD OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

SPRINKLER / STANDPIPE RISER

FIRE DEPARTMENT CONNECTION

BACKFLOW PREVENTER FLOW TEST HEADER

DOUBLE CHECK BACKFLOW PREVENTER

ABOVE GROUND SPRINKLER PIPING

BELOW GROUND SPRINKLER PIPING

PIPE BREAK / CONTINUATION

PIPE TURNED DOWN

PIPE TURNED UP

POST INDICATING VALVE (PIV)

OUTSIDE STEM & YOKE (OS&Y) VALVE

CHECK VALVE

STANDPIPE / HOSE VALVE

ORDINARY HAZARD OCCUPANCY W/

QUICK RESPONSE SPRINKLERS PER UFC 3-600-01

PENDENT SPRINKLER, RESIDENTIAL

PENDENT SPRINKLER, ORDINARY HAZARD QR

UPRIGHT SPRINKLER, RESIDENTIAL

UPRIGHT SPRINKLER, ORDINARY HAZARD QR

GENERIC VALVE

FLOOR CONTROL VALVE ASSEMBLY

SEISMIC LOOP

FIRE SUPPRESSION GENERAL NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

2. ALL NEW FIRE PROTECTION PIPING, DEVICES, COMPONENTS, AND EQUIPMENT SHALL BE LISTED AND APPROVED

FOR USE IN AUTOMATIC FIRE PROTECTION SYSTEMS.

3. ALL NEW PIPING, VALVES AND EQUIPMENT SHALL BE LABELED AND PAINTED IN ACCORDANCE WITH THE

SPECIFICATIONS.

4. DESIGN INTENT IS FOR NEW SUPPLY MAIN PIPING BETWEEN THE BACKFLOW PREVENTER AND SPRINKLER/

STANDPIPE RISERS TO BE INSTALLED IN THE GROUND FLOOR UTILIDOR (BELOW FLOOR), AND FOR ALL SPRINKLER MAINS DOWNSTREAM OF THE FLOOR CONTROL VALVES TO BE INSTALLED ABOVE CEILINGS AND BELOW STRUCTURAL BEAMS. SPRINKLER BRANCH PIPING FROM CORRIDORS INTO DWELLING UNITS OR OTHER SPACES SHALL BE INSTALLED ABOVE CEILINGS AND BELOW STRUCTURAL BEAMS WHERE POSSIBLE, OR THROUGH EXISTING WALL/BEAM PENETRATIONS OF CORRIDOR WALLS ABOVE CEILINGS. CONTRACTOR SHALL NOT CORE DRILL ANY CONCRETE BEAM OR OTHER STRUCTURAL ELEMENT WITHOUT PRIOR COORDINATION AND APPROVAL

OF STRUCTURAL.

5. PROVIDE NEW AUTOMATIC WET PIPE FIRE SPRINKLER SYSTEM THROUGHOUT THE BUILDING, INCLUDING ALL VALVES, COMPONENTS, EQUIPMENT, ETC. NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM IN ACCORDANCE WITH UFC 3-600-01 (10 MAY 2019), NFPA 13R (2019), NFPA 13 (2019, AS REFERENCED BY NFPA 13R), AND PROJECT SPECIFICATIONS. SPRINKLERS SHALL BE INSTALLED THROUGHOUT ALL AREAS OF THE BUILDING EXCEPT AS PERMITTED BY NFPA 13R, PARAGRAPHS 6.6.2 THROUGH 6.6.7, SUMMARIZED BELOW.

5.1. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS NOT LARGER THAN 5.1 SQ. M (55 SQ. FT.).

5.2. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES WITHIN

DWELLING UNITS WHERE THE AREA OF THE SPACE IS NOT LARGER THAN 2.2 SQ. M (24 SQ. FT.) AND WHERE THE WALLS AND CEILINGS ARE SURFACED WITH NON-COMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIALS.

5.3. SPRINKLERS SHALL NOT BE REQUIRED IN CRAWL SPACES, UTILIDORS, FLOOR/CEILING SPACES, OR OTHER CONCEALED SPACES NOT INTENDED FOR LIVING PURPOSES OR STORAGE AND NOT CONTAINING FUEL

BURNING EQUIPMENT.

5.4. SPRINKLERS SHALL BE REQUIRED IN ANY CLOSET USED FOR HEATING OR AIR-CONDITIONING EQUIPMENT, WASHERS, DRYERS, OR WATER HEATERS.

5.5. SPRINKLERS SHALL BE REQUIRED AT THE TOP OF EACH STAIRWELL AND BELOW THE LOWEST ACCESSIBLE

LANDING IN ACCORDANCE WITH NFPA 13, 9.3.4.2.

6. PROVIDE MANUAL WET CLASS I STANDPIPE AND HOSE VALVE SYSTEM IN EACH OF THREE EXIT STAIRS IN ACCORDANCE WITH UFC 3-600-01 AND NFPA 14 (2019). NEW RISERS SHALL UTILIZE SAME EXISTING FLOOR PENETRATIONS AS DEMOLISHED RISERS, ENLARGE PENETRATIONS AS REQUIRED FOR NEW PIPING.

7. PRESSURE REQUIREMENTS OF THE STANDPIPE SYSTEM SHALL BE MET BY THE RESPONDING FIRE DEPARTMENT PUMPER TRUCK THROUGH THE BUILDING FIRE DEPARTMENT CONNECTION AS PERMITTED BY UFC 3-600-01, PARA.

9-10.1.

8. RESIDENTIAL AREAS INCLUDE DWELLING UNITS, CORRIDORS, RESTROOMS, LOUNGES, DAY ROOMS, AND SIMILAR

AREAS. LISTED RESIDENTIAL SPRINKLERS SHALL BE USED IN ALL RESIDENTIAL AREAS.

9. ORDINARY HAZARD AREAS INCLUDE MECHANICAL / ELECTRICAL EQUIPMENT ROOMS, STORAGE ROOMS, LAUNDRY ROOMS, JANITOR CLOSETS, AND SIMILAR AREAS. LISTED RESIDENTIAL SPRINKLERS SHALL BE USED IN ORDINARY HAZARD AREAS SMALLER THAN 46 SQ. M (500 SQ. FT.), AS PERMITTED BY NFPA 13R PARAGRAPH 7.2.4.1. LISTED QUICK RESPONSE SPRINKLERS, K-115 (8.0) MINIMUM, SHALL BE USED IN ALL ORDINARY HAZARD AREAS LARGER THAN 46 SQ. M (500 SQ. FT.). EXTENDED COVERAGE SPRINKLERS SHALL NOT BE PERMITTED.

10. ALL SPRINKLERS SHALL BE ORDINARY TEMPERATURE RATED UNLESS OTHERWISE REQUIRED BY NFPA 13 OR 13R.

11. CONTRACTOR SHALL CONDUCT WATER SUPPLY FLOW TESTING IN ACCORDANCE WITH NFPA 291 PRIOR TO

BEGINNING WORK TO VERIFY WATER SUPPLY DATA PROVIDED ON THE DRAWINGS. IF FLOW TEST INDICATES GREATER WATER SUPPLY THAN THAT PROVIDED, CONTRACTOR SHALL BASE DESIGN ON FLOW TEST DATA PROVIDED ON THE DRAWINGS. IF FLOW TEST INDICATES LESSER WATER SUPPLY THAN THAT PROVIDED, COORDINATE WITH CONTRACTING OFFICER.

12. ALL ABOVE GROUND PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE FOR WELDED, THREADED, OR GROOVED FITTINGS ONLY, EXCEPT PIPING LARGER THAN 50 mm (2 IN.) MAY BE SCHEDULE 10 FOR ROLLED GROOVE OR

WELDED FITTINGS ONLY.

13. PROVIDE FLOOR CONTROL VALVE ASSEMBLY, TO INCLUDE INDICATING CONTROL VALVE WITH SUPERVISORY SWITCH, SWING CHECK VALVE, WATERFLOW SWITCH, TEST AND DRAIN ASSEMBLY, AND PRESSURE GAUGES AT

EACH FLOOR AND WHERE SHOWN ON THE DRAWINGS.

14. PROVIDE SUPERVISORY TAMPER SWITCH ON ALL SPRINKLER CONTROL VALVES. CONNECT ALL FIRE ALARM

DEVICES (SUPERVISORY AND WATERFLOW SWITCHES) TO NEW FIRE ALARM SYSTEM.

15. PROVIDE AUXILIARY DRAINS IN ACCORDANCE WITH NFPA 13. ALL DRAINS SHALL BE PIPED TO THE OUTSIDE AND SHALL BE PROVIDED WITH APPROPRIATE SPLASH PROTECTION WHERE DRAINS DO NOT DISCHARGE ONTO PAVED SURFACE. DRAINS SHALL NOT DISCHARGE DIRECTLY INTO PEDESTRIAN OR VEHICLE PATHWAYS.

16. PIPING SERVING A SINGLE SPRINKLER SHALL BE 25 mm (1 IN.) MINIMUM.

17. PIPING SHOWN IS DIAGRAMMATIC AND SHOWN ONLY FOR THE PURPOSES OF VERIFYING THE WATER SUPPLY.

CONTRACTOR SHALL PROVIDE COMPLETE SYSTEM DESIGN, INCLUDING FINAL PIPE SIZING, HYDRAULIC CALCULATIONS AND WORKING PLANS IN ACCORDANCE WITH UFC 3-600-01 AND NFPA 13R. HYDRAULIC CALCULATIONS SHALL INCLUDE A MINIMUM PRESSURE LOSS OF 55 KPA (8 PSI) ACROSS THE BACKFLOW

PREVENTER.

18. PROVIDE AUTOMATIC AIR RELEASE AT HIGH POINT OF EACH SPRINKLER / STANDPIPE RISER PER NFPA 13, PIPE

DRAIN TO BUILDING EXTERIOR OR NEAREST SYSTEM DRAIN.

19. PROVIDE AUTOMATIC PRESSURE RELIEF VALVE DOWNSTREAM OF EACH CHECK VALVE PER NFPA 13, PIPE DRAIN

TO BUILDING EXTERIOR OR NEAREST SYSTEM DRAIN.

20. COORDINATE PIPE ROUTING WITH EXISTING CONDITIONS AND OTHER TRADES PRIOR TO INSTALLATION. PIPING

SHALL NOT BE INSTALLED ABOVE ELECTRICAL PANELS AND EQUIPMENT PER NFPA 70.

21. SUPPORT ALL PIPING FROM STRUCTURE IN ACCORDANCE WITH UFC 3-310-04, NFPA 13, AND PROJECT

SPECIFICATIONS.

22. PROVIDE SEISMIC BRACING AND ISOLATION IN ACCORDANCE WITH UFC 3-310-04, NFPA 13, AND PROJECT

SPECIFICATIONS.

23. PROVIDE MINIMUM 914 mm (3 FT.) CLEAR ACCESS AROUND ALL VALVES AND EQUIPMENT.

24. PERFORM ACCEPTANCE TESTING OF ALL SYSTEMS IN ACCORDANCE WITH NFPA 13 AND PROJECT

SPECIFICATIONS. FINAL ACCEPTANCE TESTS SHALL BE WITNESSED BY THE CONTRACTING OFFICER'S

DESIGNATED REPRESENTATIVE.

WATER SUPPLY ANALYSIS

1. FLOW TEST DATA

DATE OF FLOW TEST: 19 MARCH 2018

TESTED BY: CARLO VELASCO, SSGT, USAF

WITNESSED BY: SCOTT LEOPOLD, PE

TEST HYDRANT: C51, NEAR SOUTHEAST CORNER B538

FLOW HYDRANTS: C-31, NEAR SOUTHWEST CORNER B520

C-39, NEAR NORTHEAST CORNER B520

STATIC PRESSURE: 3.86 BAR (56 PSI)

RESIDUAL PRESSURE: 2.90 BAR (42 PSI)

MEASURED FLOW: 7836 LPM (2070 GPM)

CALCULATED FLOW: (13,056 LPM @ 1.38 BAR)

(3449 GPM @ 20 PSI)

2. SPRINKLER BASIS OF DESIGN:

RESIDENTIAL PENDENT TYCO TY2234, K=70.6 (4.9)

RESIDENTIAL CONCEALED TYCO TY3596, K=70.6 (4.9)

ORDINARY HAZARD TYCO TY4231, K=115 (8.0)

3. PRELIMINARY HYDRAULIC ANALYSIS

A. RESIDENTIAL - CORRIDOR

SPRINKLER FLOW 200 LPM (53 GPM)

TOTAL FLOW 1530 LPM (404 GPM)

PRESSURE AVAILABLE 3.8 BAR (55 PSI)

PRESSURE REQUIRED 3.1 BAR (45 PSI)

SAFETY FACTOR 0.7 BAR (10 PSI)

B. RESIDENTIAL - DWELLING UNIT

SPRINKLER FLOW 150 LPM (40 GPM)

TOTAL FLOW 1480 LPM (390 GPM)

PRESSURE AVAILABLE 3.8 BAR (55 PSI)

PRESSURE REQUIRED 3.1 BAR (45 PSI)

SAFETY FACTOR 0.7 BAR (10PSI)

C. RESIDENTIAL - LAUNDRY

SPRINKLER FLOW 241 LPM (64 GPM)

TOTAL FLOW 1571 LPM (415 GPM)

PRESSURE AVAILABLE 3.8 BAR (55 PSI)

PRESSURE REQUIRED 3.4 BAR (50 PSI)

SAFETY FACTOR 0.4 BAR (5 PSI)

D. ORDINARY HAZARD - MECH ROOM 010 + 5 ADJACENT DWELLING UNITS

SPRINKLER FLOW 1426 LPM (377 GPM)

TOTAL FLOW 2756 LPM (728 GPM)

PRESSURE AVAILABLE 3.7 BAR (54 PSI)

PRESSURE REQUIRED 3.5 BAR (51 PSI)

SAFETY FACTOR 0.2 BAR (3 PSI)

THE WATER SUPPLY IS ADEQUATE TO MEET THE SYSTEM DEMAND

REQUIREMENTS WITHOUT THE NEED FOR A WATER STORAGE TANK OR FIRE

PUMP.

4. PRESSURE REQUIREMENTS OF THE MANUAL WET STANDPIPE SYSTEM WILL BE

MET BY THE LOCAL RESPONDING FIRE DEPARTMENT PUMPER TRUCK THROUGH

THE BUILDING FIRE DEPARTMENT CONNECTION (10.3 BAR [150 PSI] SUPPLIED AT

THE FIRE DEPARTMENT CONNECTION) AS PERMITTED BY UFC 3-600-01, PARA.

9-10.1 .

STANDPIPE FLOW 3800 LPM (1000 GPM)

PRESSURE AVAILABLE 10.3 BAR (150 PSI)

PRESSURE REQUIRED 9.7 BAR (140 PSI)

SAFETY FACTOR 0.6 BAR (10 PSI)

150mm FIRE SERVICE LINE, SEE CIVIL FOR CONT

PIV (SEE CIVIL)

150mm DOUBLE CHECK

BACKFLOW PREVENTER

BACKFLOW PREVENTER

TEST HEADER

FIRE DEPT. CONNECTION

STANDPIPE HOSE VALVE

AT MAIN STAIR LANDING

SPRINKLER FLOOR CONTROL

VALVE ASSEMBLY

WEST STAIR TOWER

CENTRAL STAIR TOWER

100 150 100

0 10

INDICATING CONTROL

VALVE W/TAMPER SWITCH

EAST STAIR TOWER

AUTOMATIC AIR RELEASE VALVE,

PIPE TO DRAIN OR TO OUTSIDE (TYP)

FIRE SPRINKLER DESIGN CRITERIA:

1. RESIDENTIAL AREAS / RESIDENTIAL SPRINKLERS:

REFERENCE NFPA 13R: 6.2.2, 7.1, 7.2.2 AND 7.2.4

MINIMUM SPRINKLER PRESSURE 0.48 BAR (7 PSI)

DISCHARGE SPRAY DENSITY 2.04 mm/MIN/SQ. M (0.05 GPM/SQ. FT.)

DESIGN AREA ALL SPRINKLERS WITHIN A COMPARTMENT, MAXIMUM OF 4 SPRINKLERS

2. ORDINARY HAZARD AREAS < 46 SQ. M (500 SQ. FT.) / RESIDENTIAL SPRINKLERS

REFERENCE NFPA 13R: 7.2.3.1 AND 7.2.4.1

MINIMUM SPRINKLER PRESSURE 0.48 BAR (7 PSI)

DISCHARGE SPRAY DENSITY 8 mm/MIN/SQ. M (0.20 GPM/SQ. FT.)

DESIGN AREA ALL SPRINKLERS WITHIN A COMPARTMENT, MAXIMUM OF 4 SPRINKLERS

3. ORDINARY HAZARD AREAS > 46 SQ. M (500 SQ. FT.) / QUICK RESPONSE SPRINKLERS

REFERENCE UFC 3-600-01: TABLE 9-3

MINIMUM SPRINKLER PRESSURE 0.48 BAR (7 PSI)

MINIMUM K-FACTOR 115 (8.0)

DISCHARGE SPRAY DENSITY 8 mm/MIN/SQ. M (0.20 GPM/SQ. FT.)

DESIGN AREA 230 SQ. M (2500 SQ. FT.)

S.

L

EO

PO

LD

SV

L

SW

D

FP001

FI

R

E

SU

PP

R

ES

SI

O N

G

EN

ER

AL

N O

TE

S

AN

D

L

EG

EN

D

S

FIRE PROTECTION PIPING SCHEMATIC

SCALE: NONE

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

ATC

H

LIN

E M

ATC

H

LIN

E

CORRIDOR 1

C1

FACP RM

LOBBY

RRM 1

RR1

UNIT 106

UNIT 104

UNIT 102

UNIT 101

UNIT 103

UNIT 105

UNIT 107

UNIT 109

UNIT 111

UNIT 113

UNIT 108

UNIT 110

UNIT 112

UNIT 114

LINEN 1

MECHANICAL RM

DAY ROOM 1

LG1

CORRIDOR 1W

C1W

JANITOR 1

J1

LAUNDRY 1

LD1

UNIT 123

UNIT 121

UNIT 119

STORAGE 1

ST1

UNIT 124

STAIR 1

S1

STAIR 2

S2

150mm FIRE SERVICE LINE, SEE CIVIL FOR CONT.

FIRE DEPT.

CONNECTION

150mm DOUBLE CHECK

BACKFLOW PREVENTER

SPRINKLER MAIN DOWN

TO UTILIDOR

ROUTE PIPING BELOW FLOOR IN

UTILIDOR TO SPRINKLER/STANDPIPE

RISERS IN STAIRWELLS

100mm SPRINKLER/

STANDPIPE RISER

BFP TEST

HEADER

SPRINKLER MAIN ABOVE

CORRIDOR CEILING

150 100100100 100

COORD W/ARCH FOR

HOSE VALVE CABINET

100mm STANDPIPE RISER, ROUTE

PIPING UP THROUGH EXISTING

FLOOR PENETRATIONS

100 100 75 757575

253025

253025

DESIGN AREA D,

ORDINARY HAZARD

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

S3

STAIR 3

UNIT 130

UNIT 128

UNIT 126

UNIT 136

UNIT 135

UNIT 134

UNIT 133

UNIT 125

UNIT 127

UNIT 129

UNIT 132

UNIT 131

C1E

CORRIDOR 1E

100mm STANDPIPE RISER, ROUTE

PIPING UP THROUGH EXISTING

FLOOR PENETRATIONS

SPRINKLER MAIN ABOVE

CORRIDOR CEILING

100 100

ROUTE PIPING BELOW FLOOR IN

UTILIDOR TO SPRINKLER/STANDPIPE

RISERS IN STAIRWELLS

75 75 75

25 25

DESIGN AREA D,

ORDINARY HAZARD

A

B

C

D

E

F

FIRE SUPPRESSION LEGEND

RESIDENTIAL OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

ORDINARY HAZARD OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

ORDINARY HAZARD OCCUPANCY W/

QUICK RESPONSE SPRINKLERS PER UFC 3-600-01

S.

L

EO

PO

LD

SV

L

SW

D

FP101

FI

R

E

SU

PP

R

ES

SI

O N

P

LA

N

FI

R

ST

F

LO

O

R

KEYNOTES

1 FLOOR CONTROL VALVE ASSEMBLY, SEE DETAIL 2/FP-501.

INSTALL VALVES TIGHT TO WALL ABOVE HOSE VALVE

CABINET APPROX. 2130 mm ABOVE FLOOR LEVEL. INSTALL

PIPING DOWNSTREAM OF CONTROL VALVE TO MAINTAIN

MINIMUM CLEAR HEADROOM OF 2030 mm. DO NOT ROUTE

PIPING ABOVE ELECTRICAL PANELS PER NFPA 70.

FIRE SUPPRESSION PLAN - FIRST FLOOR

SCALE: 1:100 0 1000 3000 70000 1000 3000 7000

2 SPRINKLER DRAIN, PIPE THROUGH WALL ABOVE FLOOR

AND DISCHARGE TO EXTERIOR. PROVIDE 45° TURNED

DOWN ELBOW AND SPLASH PROTECTION AT DISCHARGE.

DRAIN TO BE MINIMUM ONE PIPE SIZE LARGER THAN

LARGEST CONNECTED SECTIONAL DRAIN.

PLAN

NORTH

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

3 STANDPIPE CONTROL VALVE WITH TAMPER SWITCH

LOCATED BELOW FLOOR IN UTILIDOR.

4 PROVIDE CONTROL VALVE WITH TAMPER SWITCH IN

STAIRWELL AT BASE OF STANDPIPE BELOW FIRST HOSE

VALVE.

ATC

H

LIN

E M

ATC

H

LIN

E

CORRIDOR 2

C2

JANITOR 2

J2

UNIT 213

UNIT 211

UNIT 209

UNIT 207

UNIT 205

UNIT 203

UNIT 201

UNIT 202

UNIT 204

UNIT 206

UNIT 208

UNIT 210

UNIT 212

UNIT 214

UNIT 216

216 LAUNDRY 2

LD2

LOUNGE 2

LG2

CORRIDOR 2W

C2W

STORAGE 2

ST2

UNIT 218

UNIT 219

UNIT 222

UNIT 224

UNIT 221

UNIT 223

STAIR 1

S1

STAIR 2

S2

UNIT 225

UNIT 226

100mm SPRINKLER/

STANDPIPE RISER

SPRINKLER MAIN ABOVE

CORRIDOR CEILING

100mm STANDPIPE RISER, ROUTE PIPING THROUGH

EXISTING FLOOR PENETRATIONS

COORD W/ARCH FOR

HOSE VALVE CABINET

75 75 75 75 75

25 25

100mm STANDPIPE RISER, ROUTE PIPING

THROUGH EXISTING FLOOR PENETRATIONS

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

S3

STAIR 3

UNIT 233

UNIT 231

UNIT 229

UNIT 227

UNIT 225

UNIT 232

UNIT 230

UNIT 228

UNIT 226

UNIT 236

UNIT 234

UNIT 235

C2E

CORRIDOR 2E

SPRINKLER MAIN ABOVE

CORRIDOR CEILING

75 75 75

A

B

C

D

E

F

FIRE SUPPRESSION LEGEND

RESIDENTIAL OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

ORDINARY HAZARD OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

S.

L

EO

PO

LD

SV

L

SW

D

FP102

FI

R

E

SU

PP

R

ES

SI

O N

P

LA

N

SE

C

O N

D F

LO

O

R

FIRE SUPPRESSION PLAN - SECOND FLOOR

SCALE: 1:100

PLAN

NORTH

0 1000 3000 70000 1000 3000 7000

KEYNOTES

1 FLOOR CONTROL VALVE ASSEMBLY, SEE DETAIL 2/FP-501.

INSTALL VALVES TIGHT TO WALL ABOVE HOSE VALVE

CABINET APPROX. 2130 mm ABOVE FLOOR LEVEL. INSTALL

PIPING DOWNSTREAM OF CONTROL VALVE TO MAINTAIN

MINIMUM CLEAR HEADROOM OF 2030 mm. DO NOT ROUTE

PIPING ABOVE ELECTRICAL PANELS PER NFPA 70.

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

ATC

H

LIN

E M

ATC

H

LIN

E

CORRIDOR 3

C3

JANITOR 3

J3

UNIT 313

UNIT 311

UNIT 309

UNIT 307

UNIT 305

UNIT 303

UNIT 301

UNIT 302

UNIT 304

UNIT 306

UNIT 308

UNIT 310

UNIT 312

UNIT 314

UNIT 316

316 LAUNDRY 3

LD3

CORRIDOR 3W

C3W

STORAGE 3

ST3

LOUNGE 3

LG3

UNIT 322

UNIT 324

UNIT 323

UNIT 321

UNIT 319

UNIT 318

STAIR 1

S1

STAIR 2

S2

UNIT 325

UNIT 326

100mm SPRINKLER/

STANDPIPE RISER

SPRINKLER MAIN ABOVE

CORRIDOR CEILING

100mm STANDPIPE RISER, ROUTE PIPING THROUGH

EXISTING FLOOR PENETRATIONS

COORD W/ARCH FOR

HOSE VALVE CABINET

75 75 75 75 75

25 25

100mm STANDPIPE RISER, ROUTE PIPING

THROUGH EXISTING FLOOR PENETRATIONS

SPRINKLER MAIN ABOVE

CORRIDOR CEILING

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

S3

STAIR 3

UNIT 333

UNIT 332

UNIT 330

UNIT 331

UNIT 325

UNIT 327

UNIT 329

UNIT 328

UNIT 326

UNIT 334

UNIT 335

UNIT 336

C3E

CORRIDOR 3E75 75 75

A

B

C

D

E

F

FIRE SUPPRESSION LEGEND

RESIDENTIAL OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

ORDINARY HAZARD OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

S.

L

EO

PO

LD

SV

L

SW

D

FP103

FI

R

E

SU

PP

R

ES

SI

O N

P

LA

N

TH

IR

D F

LO

O

R

FIRE SUPPRESSION PLAN - THIRD FLOOR

SCALE: 1:100

PLAN

NORTH

0 1000 3000 70000 1000 3000 7000

KEYNOTES

1 FLOOR CONTROL VALVE ASSEMBLY, SEE DETAIL 2/FP-501.

INSTALL VALVES TIGHT TO WALL ABOVE HOSE VALVE

CABINET APPROX. 2130 mm ABOVE FLOOR LEVEL. INSTALL

PIPING DOWNSTREAM OF CONTROL VALVE TO MAINTAIN

MINIMUM CLEAR HEADROOM OF 2030 mm. DO NOT ROUTE

PIPING ABOVE ELECTRICAL PANELS PER NFPA 70.

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

ATC

H

LIN

E M

ATC

H

LIN

E

S2

STAIR 2

S1

STAIR 1

LG4

DAY ROOM 4

UNIT 418

UNIT 419

UNIT 423

ST4

STORAGE 4

UNIT 422

UNIT 424

UNIT 416

UNIT 414

UNIT 412

UNIT 410

UNIT 408

UNIT 406

UNIT 404

UNIT 402

UNIT 401

UNIT 403

UNIT 405

UNIT 407

UNIT 409

UNIT 411

UNIT 413

LD4

LAUNDRY 4

J4

JANITOR 4

UNIT 421

C4

CORRIDOR 4

C4W

CORRIDOR 4W

RR4

RRM 4

UNIT 425

UNIT 426

SPRINKLER MAIN ABOVE

CORRIDOR CEILING

100mm STANDPIPE RISER, ROUTE PIPING THROUGH

EXISTING FLOOR PENETRATIONS

100mm SPRINKLER/

STANDPIPE RISER

COORD W/ARCH FOR

HOSE VALVE CABINET

25 25

75 75 75 75 75

25 (TYP)

DESIGN AREA B,

RESIDENTIAL / DWELLING UNIT

DESIGN AREA A,

RESIDENTIAL / CORRIDOR

DESIGN AREA C,

RESIDENTIAL / LAUNDRY

100mm STANDPIPE RISER, ROUTE PIPING

THROUGH EXISTING FLOOR PENETRATIONS

SPRINKLER MAIN ABOVE

CORRIDOR CEILING

M

ATC

H

LIN

E

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

S3

STAIR 3

UNIT 425

UNIT 434

UNIT 426

UNIT 428

UNIT 430

UNIT 432

UNIT 427

UNIT 429

UNIT 431

UNIT 433

UNIT 435

C4E

CORRIDOR 4E

UNIT 436

75 75 75

A

B

C

D

E

F

FIRE SUPPRESSION LEGEND

RESIDENTIAL OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

ORDINARY HAZARD OCCUPANCY W/

RESIDENTIAL SPRINKLERS PER NFPA 13R

S.

L

EO

PO

LD

SV

L

SW

D

FP104

FI

R

E

SU

PP

R

ES

SI

O N

P

LA

N

FO

U

R

TH

F

LO

O R

FIRE SUPPRESSION PLAN - FOURTH FLOOR

SCALE: 1:100

PLAN

NORTH

0 1000 3000 70000 1000 3000 7000

KEYNOTES

1 FLOOR CONTROL VALVE ASSEMBLY, SEE DETAIL 2/FP-501.

INSTALL VALVES TIGHT TO WALL ABOVE HOSE VALVE

CABINET APPROX. 2130 mm ABOVE FLOOR LEVEL. INSTALL

PIPING DOWNSTREAM OF CONTROL VALVE TO MAINTAIN

MINIMUM CLEAR HEADROOM OF 2030 mm. DO NOT ROUTE

PIPING ABOVE ELECTRICAL PANELS PER NFPA 70.

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

FLOOR LEVEL

TO SPRINKLERS

65mm FIRE HOSE VALVE AT

EACH MAIN STAIR LANDING

100mm SPRINKLER /

STANDPIPE RISER

DRAIN RISER, ONE PIPE SIZE

LARGER THAN LARGEST

CONNECTED DRAIN. PIPE TO

OUTSIDE AT GROUND FLOOR.

FLOOR LEVEL

SIGHT GLASS

3-POSITION TEST AND DRAIN

VALVE WITH INTEGRAL ORIFICE

AND PRESSURE RELIEF,

PIPE RELIEF TO DRAIN

PRESSURE GAUGE W/GAUGE

COCK (TYP)

WATERFLOW SWITCH

SWING CHECK VALVE

INDICATING CONTROL VALVE

W/VALVE SUPERVISORY

(TAMPER) SWITCH

FL

O

W

0m m

FLOW

150mm FIRE SERVICE TO BUILDING, SEE DETAIL 7/FP501

DUCTILE IRON FLANGE

FINISHED FLOOR

PIPE TIE-RODS W/CLAMPS,

NUTS AND WASHERS

DUCTILE IRON BELL & SPIGOT PIPE

W/MECHANICAL JOINT FITTINGS

CONCRETE THRUST BLOCK,

SEE CIVIL FOR DETAILS

CORE DRILL FOUNDATION WALL MINIMUM

50mm LARGER THAN PIPE SIZE. FILL VOID

SPACE W/CONTINUOUS LINK-SEAL

REINFORCED NEOPRENE COMPRESSION

TYPE WATERPROOFING ASSEMBLY

FINISHED GRADE

EXTERIOR BUILDING WALL

150mm FIRE SERVICE SUPPLY

MAIN, SEE CIVIL FOR CONT.

THREADED ROD COUPLING

END OF BRANCH LINE SURGE RETAINER CLIP

CONTINUOUS ALL THREAD ROD (TYP)

ADJUSTABLE RING HANGER

CONCRETE ANCHOR

CONCRETE FLOOR/ROOF

ASSEMBLY

PROVIDE SECOND RESTRAINT IN

OPPOSITE DIRECTION WHERE REQUIRED

45° MIN. SWAY BRACE FITTING

SHEDULE 40 PIPE OR EQUIVALENT

PIPE CLAMP

NOTE: CONTRACTOR SHALL DESIGN AND INSTALL ALL BRACING IN

CONCRETE ANCHOR

CONCRETE FLOOR/ROOF

ASSEMBLY

NOTE: CONTRACTOR SHALL DESIGN AND INSTALL ALL BRACING IN

CONCRETE ANCHOR

SWAY BRACE FITTING

PIPE CLAMP

SCHEDULE 40 PIPE OR EQUIVALENT

SPRINKLER PIPE

CONCRETE FLOOR/ROOF

ASSEMBLY

65mm HOSE VALVE W/

CAP AND CHAIN

150mm x 350mm

FLANGE, CLASS 250

PATTERN150mm SCH. 40 PIPE

150mm WELDED CAP

65mm FIRE HOSE VALVE

W/CAP AND CHAIN, TYP.

150mm WELDED CAP

SIDE VIEW

TOP VIEW

150 TO BELOW

FLOOR UTILIDOR

OS&Y CONTROL VALVE

W/SUPERVISORY SWITCH (TYP)

150mm DOUBLE CHECK

BACKFLOW PREVENTER

150mm UNDERGROUND

FIRE SERVICE LINE,

SEE DETAIL 1/FP501

FLOOR

TO BFP TEST

HEADER

TO FDC

FDC CHECK VALVE

W/AUTOMATIC DRIP CHECK

OS&Y CONTROL VALVE,

NORMALLY CLOSED

BLIND FLANGE

S.

L

EO

PO

LD

SV

L

SW

D

FP501

FI

R

E

SU

PP

R

ES

SI

O N

D

ET

AI

LS

FIRE SERVICE ENTRANCE DETAIL

SCALE: NONE 2

FLOOR CONTROL VALVE ASSEMBLY DETAIL

SCALE: NONE

TYPICAL END HEAD RESTRAINT DETAIL

SCALE: NONE 4

TYPICAL LATERAL SWAY BRACE DETAIL

SCALE: NONE 5

TYPICAL LONGITUDINAL SWAY BRACE DETAIL

SCALE: NONE

BFP TEST HEADER DETAIL

SCALE: NONE 7

FIRE SPRINKLER RISER DETAIL

SCALE: NONE 210

R

EP

A

IR

D O

R M

, B

M

IS

A

W A

A

IR

B A

SE

JA

PA

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D

ES

C R

IP

TI

O N

D A

TE

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

FD101_FIRST FLOOR FIRE PROTECTION DEMO PLAN-Layout1
FD102_SECOND FLOOR FIRE PROTECTION DEMO PLAN-Layout1
FD103_THIRD FLOOR FIRE PROTECTION DEMO PLAN-Layout1
FD104_FOURTH FLOOR FIRE PROTECTION DEMO PLAN-Layout1
FA001_FIRE ALARM GENERAL NOTES & LEGENDS-Layout1
FA101_FIRST FLOOR FIRE ALARM PLAN-Layout1
FA102_SECOND FLOOR FIRE ALARM PLAN-Layout1
FA103_THIRD FLOOR FIRE ALARM PLAN-Layout1
FA104_FOURTH FLOOR FIRE ALARM PLAN-Layout1
FA501_FIRE ALARM DETAILS-Layout1
FA601_FIRE ALARM RISER DIAGRAM - FLOORS 1&2-Layout1
FA602_FIRE ALARM RISER DIAGRAM - FLOOR 3&4-Layout1
FP101_FIRST FLOOR FIRE SUPPRESSION PLAN-Layout1
FP102_SECOND FLOOR FIRE SUPPRESSION PLAN-Layout1
FP103_THIRD FLOOR FIRE SUPPRESSION PLAN-Layout1
FP104_FOURTH FLOOR FIRE SUPPRESSION PLAN-Layout1
FP501_FIRE SUPPRESSION DETAILS-Layout1

File details come from the government source that posted it. Updated .