Atch 2_Draft Drawing 10 Fire Protection - Repair Dorm B542.pdf
PDF 15 MB Posted
- Solicitation number
- FA520522R0001
About this file
This pre-solicitation notice is for a firm-fixed price construction contract to renovate Dormitory Building 542 at Misawa Air Base in Japan. The contractor shall provide supervision, management, labor, equipment and materials to complete interior and exterior demolition, hazardous material abatement, structural and architectural improvements, new building systems and finishes. Scope includes electrical, plumbing and telecommunications renovations along with new fire alarm, mass notification and suppression systems. Civil site work will integrate with existing sidewalks and utilities and include a new fire vehicle access lane. Exterior utilities for HVAC will also be improved. The performance period is 531 calendar days including 30 days for mobilization. The contract value is estimated between $10-25 million USD. The solicitation will issue on January 31, 2022 with proposals due around 40 days later. A pre-proposal conference is scheduled for February 25, 2022 to review requirements. The award will be a single contract determined by subjective tradeoff of past performance and price factors. Registration in SAM is required and the contractor must be authorized to operate in Japan.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
01 02 03 04 05 06 07 08 09 11 12 13 14 14'10
STAIR 2
STAIR 1
UNIT 124STORAGE 1
UNIT 119 UNIT 121 UNIT 123
LAUNDRY 1
JANITOR 1
CORRIDOR 1W
DAY ROOM 1
MECHANICAL RM
LINEN 1
UNIT 114UNIT 112UNIT 110UNIT 108
UNIT 113UNIT 111UNIT 109UNIT 107UNIT 105UNIT 103UNIT 101
UNIT 102 UNIT 104 UNIT 106
RRM 1
LOBBY
CORRIDOR 1
OFFICE
M
ATC
H
LIN
E M
ATC
H
LIN
E
EXISTING PIPING IN
BELOW FLOOR
UTILIDOR
2 2
DEMOLISH EXISTING FIRE
ALARM AND SUPPRESSION
SYSTEMS COMPLETE
WITHIN THIS BOUNDARY
FA
S
FAS FAS
S S
S S
S S
S S
S S
S S
S
S
S
S SS
HH
H
H
HH
HH
H
S S S S
DH
DH
DH
DH
DH
DH
PB
H H
S FC
P
FTR
FC
P
FPC FPC
FE
FE
FA
S
65 50
FIRE PROTECTION LEGEND - DEMOLITION
SPRINKLER / STANDPIPE RISER
FIRE DEPARTMENT CONNECTION
STANDPIPE HOSE VALVE
ELECTRIC FIRE PUMP
PIPING / EQUIPMENT TO BE DEMOLISHED
PIPE TURNED DOWN
PIPE TURNED UP
FAS FIRE ALARM STATION, JAPANESE STYLE
(PUSH STATION, ALARM BELL, LOCATION LAMP)
SMOKE DETECTORS
H HEAT DETECTOR
FIRE ALARM BELL
DOOR HOLD OPEN DEVICEDH
PUSH BUTTON MANUAL STATIONPB
UNINTERRUPTIBLE POWER SUPPLY
FIRE ALARM CONTROL PANEL
FIRE ALARM TRANSMITTER
FCP
FTR
FIRE PUMP CONTROLLERFPC
FE FIRE EXTINGUISHER
BIG VOICE LOUDSPEAKER (EXISTING TO REMAIN)
BIG VOICE CONTROLLERS (EXISTING TO REMAIN)
FA TRANSMITTER ANTENNA
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
STAIR 3
UNIT 130UNIT 128UNIT 126 UNIT 136
UNIT 135
UNIT 134
UNIT 133UNIT 125 UNIT 127 UNIT 129
UNIT 132
UNIT 131
CORRIDOR 1E
M
ATC
H
LIN
E
DEMOLISH EXISTING FIRE
ALARM AND SUPPRESSION
SYSTEMS COMPLETE
WITHIN THIS BOUNDARY
FASFAS
S S
S S
S S
S S
S S
S S
S
DH
DH
FE
A
B
C
D
E
F
S.
LE
O
PO
LD
SV
L
SW
D
FD101
FI
R
E
PR
O
TE
C
TI
O N
D
EM
O
LI
TI
O
N P
LA
N
FI
R
ST
F
LO
O R
KEYNOTES
1 DEMOLISH ELECTRIC FIRE PUMP, INCLUDING ALL PIPING,
CONTROLLERS, POWER, WIRING, AND ALL RELATED
APPURTENANCES. DRAIN AND CLEAN EXISTING BELOW
FLOOR WATER SUMP, FILL WITH SAND, AND ABANDON IN
PLACE.
GENERAL DEMOLITION NOTES:
1. FIRE PROTECTION DEMOLITION DRAWINGS ARE BASED
ON EXISTING AVAILABLE AS-BUILT DRAWINGS AND
FIELD OBSERVATIONS. CONTRACTOR SHALL VERIFY
EXISTING CONDITIONS PRIOR TO STARTING
CONSTRUCTION. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ATTENTION OF THE CONTRACTING
OFFICER PRIOR TO CONSTRUCTION.
2. DEMOLISH EXISTING FIRE ALARM, FIRE SPRINKLER,
AND STANDPIPE SYSTEMS COMPLETE, INCLUDING ALL
DEVICES, COMPONENTS, PANELS, WIRING, CONDUIT,
PIPING, VALVES, EQUIPMENT, ETC.
3. DEMOLISH UPS IN FIRE ALARM CONTROL ROOM. UPS IS
DEDICATED TO AND IS PART OF EXISTING FIRE ALARM
SYSTEM.
4. DEMOLISH ALL PORTABLE FIRE EXTINGUISHERS,
INCLUDING ALL MOUNTING BRACKETS AND EQUIPMENT.
5. DRAWINGS INDICATE GENERAL QUANTITY, LOCATION,
AND TYPES OF DEVICES AND COMPONENTS TO BE
DEMOLISHED. HOWEVER, ANY ADDITIONAL DEVICES
AND COMPONENTS FOUND TO BE EXISTING BUT NOT
SHOWN ON THE DRAWINGS SHALL BE INCLUDED IN THE
DEMOLITION.
6. ALL EXISTING FIRE ALARM CIRCUITS ARE ASSUMED TO
BE CLASS A.
7. PATCH ALL PENETRATIONS THAT WILL NOT BE REUSED
FOR NEW SYSTEMS OR EQUIPMENT.
FIRE PROTECTION DEMOLITION PLAN - FIRST FLOOR
SCALE: 1:100 0 1000 3000 7000
BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO
REMAIN.
PLAN
NORTH
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
R G
3 DEMOLISH EXISTING FIRE DEPARTMENT CONNECTION,
100mm STANDPIPE, HOSE VALVE, AND ALL
APPURTENANCES. PATCH WALL PENETRATION TO MATCH
EXISTING ADJACENT SURFACES.DRAFT
STAIR 1
UNIT 223UNIT 221
UNIT 224UNIT 222
UNIT 219
UNIT 218
STORAGE 2
CORRIDOR 2W
LOUNGE 2
LAUNDRY 2
UNIT 216UNIT 214UNIT 212UNIT 210UNIT 208UNIT 206UNIT 204UNIT 202
UNIT 201 UNIT 203 UNIT 205 UNIT 207 UNIT 209 UNIT 211 UNIT 213
JANITOR 2
CORRIDOR 2
M
ATC
H
LIN
E M
ATC
H
LIN
E
2 2
DEMOLISH EXISTING FIRE
ALARM AND SUPPRESSION
SYSTEMS COMPLETE
WITHIN THIS BOUNDARY
FAS FAS
S S
S S
S S
S S
S S
S S
S
S
S
S SS
S S S S
DH
DH
DH
DH
DH
DH
H
S
H
H
S S
H
H
FEFE
FE
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
STAIR 3
UNIT 233UNIT 231UNIT 229UNIT 227UNIT 225
UNIT 232UNIT 230UNIT 228UNIT 226 UNIT 236UNIT 234
UNIT 235
CORRIDOR 2E
M
ATC
H
LIN
E
DEMOLISH EXISTING FIRE
ALARM AND SUPPRESSION
SYSTEMS COMPLETE
WITHIN THIS BOUNDARY
FASFAS
S S
S S
S S
S S
S S
S S
S
DH
DH
FE
A
B
C
D
E
F
S.
LE
O
PO
LD
SV
L
SW
D
FD102
FI
R
E
PR
O
TE
C
TI
O N
D
EM
O
LI
TI
O
N P
LA
N
SE
C O
N D
F
LO
O R
FIRE PROTECTION DEMOLITION PLAN - SECOND FLOOR
SCALE: 1:100 0 1000 3000 7000
KEYNOTES
1 DEMOLISH COMMERCIAL KITCHEN HOOD AND INTEGRAL
WET CHEMICAL FIRE SUPPRESSION SYSTEM, INCLUDING
ALL PIPING, COMPONENTS AND CONTROLS.
2 BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO
REMAIN.
PLAN
NORTH
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
R G
3 DEMOLISH EXISTING 100mm STANDPIPE, HOSE VALVE, AND
ALL APPURTENANCES. EXISTING FLOOR PENETRATION TO
REMAIN.
DRAFT
STAIR 1
UNIT 318
UNIT 319 UNIT 321 UNIT 323
UNIT 324UNIT 322
LOUNGE 3 STORAGE 3
CORRIDOR 3W
LAUNDRY 3UNIT 316UNIT 314UNIT 312UNIT 310UNIT 308UNIT 306UNIT 304UNIT 302
UNIT 301 UNIT 303 UNIT 305 UNIT 307 UNIT 309 UNIT 311 UNIT 313
JANITOR 3
CORRIDOR 3
M
ATC
H
LIN
E M
ATC
H
LIN
E
2 2
DEMOLISH EXISTING FIRE
ALARM AND SUPPRESSION
SYSTEMS COMPLETE
WITHIN THIS BOUNDARY
FAS FAS
S S
S S
S S
S S
S S
S S
S
S
S
S SS
S S S S
DH
DH
DH
DH
DH
DH
H
S
H
H
S S
H
H
FEFE
FE
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
STAIR 3
UNIT 333
UNIT 332UNIT 330
UNIT 331UNIT 325 UNIT 327 UNIT 329
UNIT 328UNIT 326 UNIT 334
UNIT 335
UNIT 336
CORRIDOR 3E
M
ATC
H
LIN
E
DEMOLISH EXISTING FIRE
ALARM AND SUPPRESSION
SYSTEMS COMPLETE
WITHIN THIS BOUNDARY
FAS
S S
S S
S S
S S
S S
S S
S
DH
DH
FAS FE
A
B
C
D
E
F
S.
LE
O
PO
LD
SV
L
SW
D
FD103
FI
R
E
PR
O
TE
C
TI
O N
D
EM
O
LI
TI
O
N P
LA
N
TH
IR
D
F
LO
O R
FIRE PROTECTION DEMOLITION PLAN - THIRD FLOOR
SCALE: 1:100 0 1000 3000 7000
KEYNOTES
1 DEMOLISH COMMERCIAL KITCHEN HOOD AND INTEGRAL
WET CHEMICAL FIRE SUPPRESSION SYSTEM, INCLUDING
ALL PIPING, COMPONENTS AND CONTROLS.
2 BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO
REMAIN.
PLAN
NORTH
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
R G
3 DEMOLISH EXISTING 100mm STANDPIPE, HOSE VALVE, AND
ALL APPURTENANCES. EXISTING FLOOR PENETRATION TO
STAIR 1
DAY ROOM 4
UNIT 418
UNIT 419 UNIT 423
STORAGE 4
UNIT 422 UNIT 424UNIT 416UNIT 414UNIT 412UNIT 410UNIT 408UNIT 406UNIT 404UNIT 402
UNIT 401 UNIT 403 UNIT 405 UNIT 407 UNIT 409 UNIT 411 UNIT 413
LAUNDRY 4
JANITOR 4
UNIT 421
CORRIDOR 4CORRIDOR 4W
RRM 4
M
ATC
H
LIN
E M
ATC
H
LIN
E
FAS FAS
S S
S S
S S
S S
S S
S S
S
S
S
S SS
S S S S
DH
DH
DH
DH
DH
DH
S
H
H
S S
H
H
FE
FE
DEMOLISH EXISTING FIRE
ALARM AND SUPPRESSION
SYSTEMS COMPLETE
WITHIN THIS BOUNDARY
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
STAIR 3
UNIT 425
UNIT 434UNIT 426 UNIT 428 UNIT 430 UNIT 432
UNIT 427 UNIT 429 UNIT 431 UNIT 433 UNIT 435
CORRIDOR 4E
UNIT 436
M
ATC
H
LIN
E
FAS
S S
S S
S S
S S
S S
S S
S
DH
DH
FAS FE
DEMOLISH EXISTING FIRE
ALARM AND SUPPRESSION
SYSTEMS COMPLETE
WITHIN THIS BOUNDARY
A
B
C
D
E
F
S.
LE
O
PO
LD
SV
L
SW
D
FD104
FI
R
E
PR
O
TE
C
TI
O N
D
EM
O
LI
TI
O
N P
LA
N
FO
U R
TH
F
LO
O
R
FIRE PROTECTION DEMOLITION PLAN - FOURTH FLOOR
SCALE: 1:100 0 1000 3000 7000
KEYNOTES
BIG VOICE SYSTEM CONTROL EQUIPMENT IS EXISTING TO
REMAIN.
2 BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO
REMAIN.
3 DEMOLISH EXISTING FIRE ALARM TRANSMITTER ANTENNA
AND ALL ASSOCIATED WIRING, SUPPORTS AND
APPURTENANCES.
PLAN
NORTH
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
R G
4 DEMOLISH EXISTING 100mm STANDPIPE, HOSE VALVE, AND
ALL APPURTENANCES. EXISTING FLOOR PENETRATION TO
FIRE ALARM LEGEND
FIRE ALARM ANNUNCIATOR
FIRE ALARM / MASS NOTIFICATION TRANSMITTERFTR
FAA
FIRE ALARM / MASS NOTIFICATION SYSTEM CONTROL PANELFMCP
LOCAL OPERATING CONSOLELOC
H BIG VOICE LOUDSPEAKER (EXISTING TO REMAIN)
BIG VOICE CONTROLLERS (EXISTING TO REMAIN)CPBV
S SPOT TYPE SMOKE DETECTOR
S SPOT TYPE SMOKE DETECTOR W/SOUNDER BASESB
MANUAL FIRE ALARM STATIONF
DOOR HOLD OPEN DEVICEDH
WATERFLOW ALARM BELL, WEATHER PROOF DEVICE
SPEAKER / STROBE (##=CANDELA)
SPEAKER
ET VISUAL TEXT DISPLAY SIGN
SPRINKLER WATERFLOW SWITCH
SPRINKLER VALVE SUPERVISORY SWITCH
WF
VS
SPEAKER, WEATHER PROOF DEVICE
WP
FIRE ALARM TERMINAL CABINET
FA / MNS TRANSMITTER ANTENNA
FATC
LINE ISOLATION MODULE
ADDRESSABLE INPUT MODULE
ADDRESSABLE OUTPUT MODULE
WP
TEXT SIGN CONTROLLERTSC
K KEY SAFE (KNOX BOX)
FIRE ALARM GENERAL NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
2. ALL NEW FIRE PROTECTION DEVICES, COMPONENTS, AND EQUIPMENT SHALL BE LISTED AND APPROVED FOR USE
IN AUTOMATIC FIRE PROTECTION SYSTEMS.
3. ALL NEW CONDUIT, COMPONENTS AND EQUIPMENT SHALL BE LABELED AND PAINTED IN ACCORDANCE WITH THE
SPECIFICATIONS.
4. COORDINATE WITH STRUCTURAL PRIOR TO CORE DRILLING ANY WALL OR STRUCTURAL ELEMENT.
5. PROVIDE COMBINED ADDRESSABLE FIRE ALARM / MASS NOTIFICATION SYSTEM THROUGHOUT ENTIRE BUILDING IN
ACCORDANCE WITH UFC 3-600-01 (10 MAY 2019), 4-021-01 (01 JAN 2010), NFPA 72 (2019), AND PROJECT
SPECIFICATIONS.
6. DRAWINGS ARE CONCEPTUAL IN NATURE AND INDICATE DESIGN INTENT AND APPROXIMATE DEVICE LOCATIONS.
CONTRACTOR SHALL COORDINATE WITH OTHER TRADES AND CEILING MOUNTED DEVICES AND EQUIPMENT AND PROVIDE ALL NECESSARY DEVICES AND COMPONENTS FOR FULLY FUNCTIONAL CODE COMPLIANT SYSTEM. FINAL DEVICE QUANTITIES, LOCATIONS, CANDELA RATINGS, ETC. SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 72
AND SHALL BE SHOWN ON CONTRACTOR SHOP DRAWINGS.
7. ALL INITIATING, NOTIFICATION, AND SIGNALING LINE CIRCUITS SHALL BE CLASS B. SLC LOOPS SHALL BE
PERMITTED PER NFPA 72.
8. PROVIDE SPEAKER LAYOUT TO ENSURE THE AUDIBILITY AND INTELLIGIBILITY REQUIREMENTS OF UFC 4-021-01 AND NFPA 72 ARE MET. PROVIDE MINIMUM CIS LEVEL OF 0.80 IN NORMALLY OCCUPIED SPACES. AREAS OF THE BUILDING NOT NORMALLY EXPECTED TO BE OCCUPIED (STORAGE AND EQUIPMENT ROOMS) MAY HAVE A LOWER CIS SCORE IF PERSONNEL CAN DETERMINE THAT A VOICE MESSAGE IS BEING BROADCAST AND MAY WALK NO MORE THAN 15.3 M (50 FT.) TO A LOCATION WITH AT LEAST A 0.80 CIS. PROVIDE AUDIBILITY AND INTELLIGIBILITY
ANALYSIS CALCULATIONS IN ACCORDANCE WITH SPECIFICATIONS.
9. PROVIDE FIRE ALARM ANNUNCIATOR PANEL WITH LCD DISPLAY. PROVIDE PRINTED AND FRAMED BUILDING FLOOR PLAN ON WALL ADJACENT TO ANNUNCIATOR PANEL. FLOOR PLAN SHALL INDICATE ALL ROOMS AND FIRE ALARM DEVICES TO FACILITATE PHYSICAL LOCATION BASED UPON THE LCD DISPLAY INFORMATION FOR EACH DEVICE.
10. PROVIDE WORKING PLANS AND CALCULATIONS PREPARED BY OR UNDER THE DIRECT SUPERVISION OF A REGISTERED FIRE PROTECTION ENGINEER OR AN INDIVIDUAL WHO HAS OBTAINED LEVEL III CERTIFICATION FROM THE NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES (NICET), FIRE ALARM SYSTEMS SUBFIELD. DRAWINGS SHALL BE FULL SIZE DRAWINGS, MINIMUM 1:100 SCALE (1/8" = 1'-0").
11. PROVIDE A DOCUMENTATION CABINET ADJACENT TO THE FIRE ALARM CONTROL PANEL, OR OTHER LOCATION AS APPROVED BY THE CONTRACTING OFFICER, WITH FIRE ALARM AND FIRE SUPPRESSION SYSTEM AS-BUILT
DRAWINGS, O&M MANUALS, AND CD/DVD WITH SOFTWARE COPIES.
12. PROVIDE SPARE PARTS CABINET ADJACENT TO THE FIRE ALARM CONTROL PANEL, OR OTHER LOCATION AS APPROVED BY THE CONTRACTING OFFICER, WITH MANUFACTURER'S RECOMMENDED SPARE PARTS.
13. PROVIDE FIRE ALARM / MASS NOTIFICATION SYSTEM CONTROL PANELS, ANNUNCIATOR PANELS, LOCAL OPERATING CONSOLES, AND OTHER EQUIPMENT COMPATIBLE WITH EXISTING BASEWIDE REPORTING SYSTEM EQUIPMENT. EXISTING FIRE ALARM REPORTING SYSTEM IS MONACO RADIO TRANSCEIVER SYSTEM.
14. PROVIDE RADIO TRANSMITTER/COMMUNICATOR AND OMNI-DIRECTIONAL ANTENNA COMPATIBLE WITH EXISTING BASEWIDE MONACO RADIO REPORTING SYSTEM. COORDINATE ANTENNA LOCATION WITH LOCAL BASE FIRE
DEPARTMENT.
15. PROVIDE SURGE SUPPRESSION AT ALL CIRCUITS, POWER SUPPLIES, ETC. ENTERING OR LEAVING THE BUILDING, EXCEPT SURGE SUPPRESSION SHALL NOT BE REQUIRED FOR DEVICES MOUNTED DIRECTLY TO THE BUILDING
EXTERIOR.
16. ALL DEVICES INSTALLED OUTDOORS OR IN SHOWER AREAS SHALL BE WEATHERPROOF AND LISTED FOR USE AT THE EXPECTED MINIMUM/MAXIMUM AMBIENT TEMPERATURE AND HUMIDITY FOR THE LOCATION. PROVIDE
SEPARATE CIRCUIT FOR ALL DEVICES INSTALLED OUTDOORS.
17. SMOKE DETECTORS SHALL NOT BE INSTALLED LESS 915MM (3 FT.) FROM ANY BATHROOM DOOR, HVAC SUPPLY OUTLET OR RETURN GRILL, UNLESS THIS WOULD PREVENT THE INSTALLATION OF ANY REQUIRED DETECTOR.
18. PROVIDE WALL MOUNTED LED TEXT DISPLAY SIGNS ABOVE (OR ADJACENT TO) EXITS WHERE SHOWN ON THE
DRAWINGS.
19. PROVIDE SMOKE DETECTOR WITH SOUNDER BASE IN ALL SLEEPING ROOMS AS SHOWN ON THE DRAWINGS.
SOUNDER SHALL BE CAPABLE OF PRODUCING A 520 HZ TEMPORAL THREE (T3) SIGNAL FOR FIRE IN ACCORDANCE
WITH UFC 3-600-01 AND NFPA 72.
20. COMPLETE PRE-FINAL TEST AND INSPECTION, TO INCLUDE CONFIRMATION OF RECEIPT OF ALL SIGNALS AT REPORTING STATION, BEFORE SUBMITTING REQUEST TO SCHEDULE FINAL TESTING. AFTER PRELIMINARY TESTS HAVE BEEN SUCCESSFULLY COMPLETED, PERFORM ALL FINAL TESTING IN ACCORDANCE WITH SPECIFICATIONS AND NFPA 72. ALL PRELIMINARY AND FINAL TESTING SHALL BE WITNESSED AND APPROVED BY THE CONTRACTOR'S QUALIFIED ENGINEER AND THE CONTRACTING OFFICER'S DESIGNATED REPRESENTATIVE.
MANUAL FIRE ALARM STATION
FIRE ALARM / MASS NOTIFICATION
SYSTEM SEQUENCE OF OPERATION
TRANSMIT FIR
E ALA
RM SIG
NAL T
O BASEWID
E
REPORTIN
G SYSTEM
TRANSMIT SUPERVISORY SIG
NAL T
O BASEWID
E
REPORTIN
G SYSTEM
TRANSMIT TROUBLE
SIG
NAL T
O BASEWID
E
REPORTIN
G SYSTEM
TRANSMIT W
ATERFLO
W ALA
RM SIG
NAL T
O
BASEWID
E R
EPORTIN
G SYSTEM
TRANSMIT M
NS O
VERRID
E SIG
NAL T
O BASEWID
E
REPORTIN
G SYSTEM (IF
ACTIVE FIR
E ALA
RM PRESENT)
AUDIO
/VISUAL F
IR
E ALA
RM IN
DIC
ATIO
N BY
ZONE/D
EVIC
E AT THE FMCP
AUDIO
/VISUAL S
UPERVISORY IN
DIC
ATIO
N BY
ZONE/D
EVIC
E AT THE FMCP
AUDIO
/VISUAL T
ROUBLE
IN
DIC
ATIO
N BY
ZONE/D
EVIC
E AT THE FMCP
ACTIVATE AUDIBLE
/TEXTUAL
NOTIFIC
ATIO
N
APPLIA
NCES AND VISIBLE
STROBES
ACTIVATE SMOKE D
ETECTOR SOUNDER BASE IN
AFFECTED D
WELL
IN
G U
NIT / S
LE
EPIN
G R
OOM
ACTIVATE EXTERIO
R W
ATERFLO
W ALA
RM
RELE
ASE D
OOR H
OLD
O
PEN D
EVIC
ES
OVERRID
E FIR
E ALA
RM AUDIBLE
/TEXTUAL M
ESSAGE W
ITH
MNS ANNOUNCEMENT (IF
ACTIVE FIR
E ALA
RM PRESENT)
REACTIVATE FIR
E ALA
RM M
ESSAGE
(IF
ACTIVE FIR
E ALA
RM PRESENT)
ALARM
SYSTEM INPUTS
SYSTEM O
UTPUTS
SPOT TYPE SMOKE DETECTOR
SPRINKLER WATERFLOW SWITCH
EXTERNAL MNS INPUT
ACTIVATE LOC, LIVE MNS ANNOUNCEMENT
ACTIVATE PRE-RECORDED MNS ANNOUNCEMENT
SPRINKLER VALVE TAMPER SWITCH
SUPERVISORY
KEY SAFE (KNOX BOX) TAMPER SWITCH
TROUBLE
LOW BATTERY VOLTAGE
AC POWER FAILURE
SUPERVISED COMPONENT FAILURE
CIRCUIT FAULT
GROUND FAULT
SPOT TYPE SMOKE DETECTOR W/ SOUNDER BASE
(DWELLING UNIT / SLEEPING ROOM)
TRANSMITTER CONTROL PANEL
1 MINUTE AFTER LAST LIVE MNS ANNOUNCEMENT, OR
10 MINUTES AFTER LAST PRE-RECORDED ANNOUNCEMENT
S.
LE
O
PO
LD
SV
L
SW
D
FA001
FI
R
E
AL
AR
M
G
EN
ER
AL
N O
TE
S
AN
D
L
EG
EN
D
S
FIRE ALARM / MASS NOTIFICATION OPERATIONS MATRIX
SCALE: NONE
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
R
GDRAFT
M
ATC
H
LIN
E M
ATC
H
LIN
E
FA
A
LO
C
FT
R
FM
C
P
S
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB
S SB
S SB
S SB S SBS SB
F
F
S
DH
DH
ET ET
WF
VS
WP
WP
WP
F
D H
VS
VS
VS
WP WP
WP WP
WP WP
WP WP
WP WP
WP WP
WP
WP
WP WP WP
WPD
H
F
CORRIDOR 1
C1
FACP RM
LOBBY
RRM 1
RR1
UNIT 106
UNIT 104
UNIT 102
UNIT 101
UNIT 103
UNIT 105
UNIT 107
UNIT 109
UNIT 111
UNIT 113
UNIT 108
UNIT 110
UNIT 112
UNIT 114
LINEN 1
MECHANICAL RM
DAY ROOM 1
LG1
CORRIDOR 1W
C1W
JANITOR 1
J1
LAUNDRY 1
LD1
UNIT 123
UNIT 121
UNIT 119
STORAGE 1
ST1
UNIT 124
STAIR 1
S1
STAIR 2
S2
WP
15 15 15
S
S
S
S
S
VS
VS
K
UNIT 126
UNIT 125
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M
ATC
H
LIN
E
F
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
DH
DHET
WPWP WP
WP WP
WP WP
WP WP
WP WP
WP WP
S S3
STAIR 3
UNIT 130
UNIT 128
UNIT 126
UNIT 136
UNIT 135
UNIT 134
UNIT 133
UNIT 125
UNIT 127
UNIT 129
UNIT 132
UNIT 131
C1E
CORRIDOR 1E
15 15 S
VS
A
B
C
D
E
F
S.
LE
O
PO
LD
SV
L
SW
D
FA101
FI
R
E
AL
AR
M
P
LA
N
FI
R
ST
F
LO
O
R
FIRE ALARM PLAN - FIRST FLOOR
SCALE: 1:100 0 1000 3000 7000
KEYNOTES
BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO
REMAIN.
1 1
PROVIDE WEATHERPROOF EXTERIOR WATERFLOW ALARM
BELL. BELL TO SOUND ON ANY SPRINKLER WATERFLOW.
PLAN
NORTH
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
R G
3 STANDPIPE CONTROL VALVE AND SUPERVISORY TAMPER
SWITCH LOCATED IN UNDERFLOOR UTILIDOR.
ATC
H
LIN
E M
ATC
H
LIN
E
LO
C
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB S SB
S SB
S SB S SBS SB
FDH
DH
ET
WF
VS
S SB S SB S SB S SB
WP WP
WP WP
WP WP
WP WP
WP WP
WP WP
WP
WP WP
WP WP WP
WP WPWP D
H
ET F
CORRIDOR 2
C2
JANITOR 2
J2
UNIT 213
UNIT 211
UNIT 209
UNIT 207
UNIT 205
UNIT 203
UNIT 201
UNIT 202
UNIT 204
UNIT 206
UNIT 208
UNIT 210
UNIT 212
UNIT 214
UNIT 216
216 LAUNDRY 2
LD2
LOUNGE 2
LG2
CORRIDOR 2W
C2W
STORAGE 2
ST2
UNIT 218
UNIT 219
UNIT 222
UNIT 224
UNIT 221
UNIT 223
STAIR 1
S1
STAIR 2
S2
151515
S
FATC
D H
SS
S
S S
S
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M
ATC
H
LIN
E
F
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
DH
DHET
WP WP
WP WP
WP WP
WP WP
WP WP
WP WP
S3
STAIR 3
UNIT 233
UNIT 231
UNIT 229
UNIT 227
UNIT 225
UNIT 232
UNIT 230
UNIT 228
UNIT 226
UNIT 236
UNIT 234
UNIT 235
C2E
CORRIDOR 2E
15 15 S S
A
B
C
D
E
F
S.
LE
O
PO
LD
SV
L
SW
D
FA102
FI
R
E
AL
AR
M
P
LA
N
SE
C
O N
D F
LO
O
R
KEYNOTES
FIRE ALARM PLAN - SECOND FLOOR
SCALE: 1:100 0 1000 3000 7000
BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO
REMAIN, TYPICAL EACH FLOOR.
1 1
PLAN
NORTH
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
ATC
H
LIN
E M
ATC
H
LIN
E
LO
C
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB S SB
S SB
S SB S SBS SB
FDH
DH
ET
WF
VS
S SB S SB S SB S SB
WP WP
WP WP
WP WP
WP WP
WP WP
WP WP
WP
WP WP WP WP WP
WP WP WP
D H
ET F
CORRIDOR 3
C3
JANITOR 3
J3
UNIT 313
UNIT 311
UNIT 309
UNIT 307
UNIT 305
UNIT 303
UNIT 301
UNIT 302
UNIT 304
UNIT 306
UNIT 308
UNIT 310
UNIT 312
UNIT 314
UNIT 316
316 LAUNDRY 3
LD3
CORRIDOR 3W
C3W
STORAGE 3
ST3
LOUNGE 3
LG3
UNIT 322
UNIT 324
UNIT 323
UNIT 321
UNIT 319
UNIT 318
STAIR 1
S1
STAIR 2
S2
15 15 15
S
FATC
D H
SS
S
S S
S
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M
ATC
H
LIN
E
F
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
DH
DHET
WP WP
WP WP
WP WP
WP WP
WP WP
WP WP
S3
STAIR 3
UNIT 333
UNIT 332
UNIT 330
UNIT 331
UNIT 325
UNIT 327
UNIT 329
UNIT 328
UNIT 326
UNIT 334
UNIT 335
UNIT 336
C3E
CORRIDOR 3E
15 15 S S
A
B
C
D
E
F
S.
LE
O
PO
LD
SV
L
SW
D
FA103
FI
R
E
AL
AR
M
P
LA
N
TH
IR
D F
LO
O
R
KEYNOTES
FIRE ALARM PLAN - THIRD FLOOR
SCALE: 1:100 0 1000 3000 7000
BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO
REMAIN.
1 1
PLAN
NORTH
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
ATC
H
LIN
E M
ATC
H
LIN
E
LO
C
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB S SB
S SB
S SB S SBS SB
FDH
DH
ET
WF
VS
S SB S SB S SB S SB
WP WP
WP WP
WP WP
WP WP
WP WP
WP WP
WP
WP WP WP WP WP
WP WP WP
D H
ET F
S2
STAIR 2
S1
STAIR 1
LG4
DAY ROOM 4
UNIT 418
UNIT 419
UNIT 423
ST4
STORAGE 4
UNIT 422
UNIT 424
UNIT 416
UNIT 414
UNIT 412
UNIT 410
UNIT 408
UNIT 406
UNIT 404
UNIT 402
UNIT 401
UNIT 403
UNIT 405
UNIT 407
UNIT 409
UNIT 411
UNIT 413
LD4
LAUNDRY 4
J4
JANITOR 4
UNIT 421
C4
CORRIDOR 4
C4W
CORRIDOR 4W
RR4
RRM 4
15 15 15
S
FATC
D H
SS
S
S S
S
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M
ATC
H
LIN
E
F
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
S SB S SB
DH
DHET
WP WP
WP WP
WP WP
WP WP
WP WP
WP WP
S3
STAIR 3
UNIT 425
UNIT 434
UNIT 426
UNIT 428
UNIT 430
UNIT 432
UNIT 427
UNIT 429
UNIT 431
UNIT 433
UNIT 435
C4E
CORRIDOR 4E
UNIT 436
15 15 S S
A
B
C
D
E
F
S.
L
EO
PO
LD
SV
L
SW
D
FA104
FI
R
E
AL
AR
M
P
LA
N
FO
U
R
TH
F
LO
O R
KEYNOTES
FIRE ALARM PLAN - FOURTH FLOOR
SCALE: 1:100 0 1000 3000 7000
BIG VOICE SYSTEM LOUDSPEAKERS ARE EXISTING TO
REMAIN.
1 1
EXISTING BIG VOICE CONTROL EQUIPMENT TO REMAIN.3
PROVIDE NEW ROOFTOP FA / MNS TRANSMITTER ANTENNA
AND ALL REQUIRED WIRING AND SUPPORTS FOR
COMPLETELY OPERATIONAL SYSTEM. NEW ANTENNA SHALL
BE COMPATIBLE WITH EXISTING BASEWIDE MONACO RADIO
REPORTING SYSTEM. COORDINATE FINAL ANTENNA
LOCATION WITH LOCAL FIRE DEPARTMENT.
PLAN
NORTH
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
NOTES:
1 ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED OTHERWISE.
2 IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR AUDIO
DEVICES WHILE LEAVING A MINIMUM OF 150 MILLIMETERS BETWEEN THE
CEILING AND THE TOP OF THE AUDIO DEVICE, THE DEVICE SHALL BE MOUNTED
AT 150 MILLIMETERS BELOW CEILING MEASURED TO THE TOP OF THE DEVICE.
3 IF CEILING HEIGHT DOES NOT PERMIT MOUNTING HEIGHTS NOTED FOR VISUAL
OR AUDIO/VISUAL DEVICE, THE DEVICE SHALL BE MOUNTED NOT MORE THAN
150 MILLIMETERS BELOW CEILING MEASURED TO THE TOP OF THE DEVICE.
AUDIO DEVICE
M
IN
FLOOR
CEILING
M
IN
VISUAL OR
AUDIO/VISUAL DEVICE
MANUAL ALARM
PULL STATION
M
IN
M
AX
1500 MAX.
M
IN
M
AX
CEILING
W
AL
L
M
AX
SMOKE DETECTOR ACCEPTABLE
ANYWHERE ON CEILING
TOP OF SMOKE DETECTOR ACCEPTABLE
ON WALL WITHIN 300 mm OF CEILING
TOP OF SMOKE DETECTOR NOT ACCEPTABLE
MORE THAN 300 mm BELOW CEILING
NOTES:
1 ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED OTHERWISE.
M
IN
IM
U
M
M
IN
IM
U
M
M
IN
IM
U M
FA / MNS TRANSMITTER
ANTENNA
ANTENNA MAST
ROOF
WALL MOUNTED MAST
SUPPORT BRACKET
ARRESTOR (SEE INSET)
21 mm (3/4") CONDUIT
FA / MNS TRANSCEIVER
WEATHER PROOF J-BOX W/COVER;
PROVIDE GROMMETED RUBBER BUSHING
FOR CABLE ENTRANCE TO J-BOX.
TO ANTENNA
ARRESTOR
TO BUILDING GROUND
FROM FA / MNS TRANSCEIVER
ARRESTOR (SEE INSET)
FMCP
FIRE ALARM TRANSCEIVER MAIN SERVICE
OR SUB-PANEL
21 mm (3/4") EMT W/COAX
16 mm (1/2") EMT W/#10 COPPER
BUILDING GROUND, SEE NOTE 2
NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED OTHERWISE.
2. AVOID SHARP BENDS IN BOTH COAX CABLE AND GROUND CONDUCTOR.
3. GROUND PER NFPA 70, ARTICLE 810.
MNS TRANSCEIVER
S.
L
EO
PO
LD
SV
L
SW
D
FA501
FI
R
E
AL
AR
M
D
ET
AI
LS
TYPICAL FIRE ALARM DEVICE MOUNTING DETAIL
SCALE: NONE
TYPICAL FIRE ALARM DETECTOR MOUNTING DETAIL
SCALE: NONE
FIRE ALARM TRANSMTTER ANTENNA DETAIL
SCALE: NONE 202
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
BATTERY
FTR FMCP
GROUND
ANTENNA
LOC
FAA
S SB
TO 120V
POWER
U N
IT
ET
S F
DH
COAXIAL LIGHTNING
ARRESTOR
ET
F
ST
AI
R
-1
VS WF
LA
U
N D
R Y
LD
F
DH
DH
VSVSVS
TO 2ND FLOOR LOC
S
FA
C
P R
M
LO
BB
Y
WP
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
ST
AI
R
-1
WP
S
C O
R R
ID
O
R C
1E
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
M
EC
H R
O O
M
DH
C O
R R
ID
O
R C
ST
O
R
AG
E
ST
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
DH DH
ST
AI
R
-1
WP
ET
FS
C O
R R
ID
O
R C
1W
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
D
AY
R O
O M
L G
15 15 15
1530151575
TO 2ND FLOOR
TERMINAL CABINET
2ND FLOOR
LOC
S SB
U N
IT
ET
F
DH
ET
ST
AI
R
-2
VS WF
F
DH
DH
TO 3RD FLOOR LOC
S
ST
O
R
AG
E
ST
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
ST
AI
R
-2
S S
C O
R R
ID
O
R C
2E
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
C O
R R
ID
O
R C
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
WP
S SB
U N
IT
WP
S SB
DH DH
ST
AI
R
-2
ET
FS
C O
R R
ID
O
R C
2W
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
U N
IT
WP
S SB
LO
U
N G
E
LG
15 15
15151575
TO 3RD FLOOR
TERMINAL CABINET
TO 1ST FLOOR LOC
TO FMCP
TERMINAL CABINET
S SB
U N
IT
WP 30
DH
LA
U
N D
R Y
LD
U N
IT
U N
IT
WP
S SB
U N
IT
WP
S SB
WP
F
SSS S
C O
R R
ID
O
R C
1E
S
TO 2ND FLOOR
VS
VSVS
TO 1ST FLOOR
TO 3RD FLOOR
S
S SS
S
TO WATERFLOW BELL
TSC
WP
S.
L
EO
PO
LD
SV
L
SW
D
FA601
FI
R
E
AL
AR
M
R
IS
ER
D
IA
G
R
AM
FL
O O
R S
1&
FIRE ALARM RISER DIAGRAM - FLOORS 1&2
SCALE: NONE 203
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
U N
IT
ST
AI
R
-4
ST
O
R
AG
E
ST
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
ST
AI
R
-4
C O
R R
ID
O
R C
4E
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
C
O R
R
ID
O R
C
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
ST
AI
R
-4
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
D
AY
R O
O M
L G
TO 3RD FLOOR LOC
TO 3RD FLOOR
TERMINAL CABINET
U N
IT
LA
U
N D
R Y
LD
U N
IT
U N
IT
U N
IT
C O
R R
ID
O
R C
4W
4TH FLOOR
LOC
S SB
ET
F
DH
ET
VS WF
F
DH
DH
S
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S S S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
DH DH
ET
FS
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
15 15
15151575
TERMINAL CABINET
S SB
WP 30
DH
WP
S SB
WP
S SB
TO 3RD FLOOR
S
S SS
S
3RD FLOOR
U N
IT
ST
AI
R
-3
TO 4TH FLOOR LOC
ST
O
R
AG
E
ST
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
ST
AI
R
-3
C O
R R
ID
O
R C
3E
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
C
O R
R
ID
O R
C
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
ST
AI
R
-3
C O
R R
ID
O
R C
3W
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
U N
IT
LO
U
N G
E
LG
TO 4TH FLOOR
TERMINAL CABINET
TO 2ND FLOOR LOC
TO 2ND FLOOR
TERMINAL CABINET
U N
IT
LA
U
N D
R Y
LD
U N
IT
U N
IT
U N
IT
LOC
S SB
ET
F
DH
ET
VS WF
F
DH
DH
S
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S S S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
DH DH
ET
FS
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
WP
S SB
15 15
15151575
TERMINAL CABINET
S SB
WP 30
DH
WP
S SB
WP
S SB
TO 2ND FLOOR
TO 4TH FLOOR
S
S SS
S
S.
L
EO
PO
LD
SV
L
SW
D
FA602
FI
R
E
AL
AR
M
R
IS
ER
D
IA
G
R
AM
FL
O O
R S
3&
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
R G
FIRE ALARM RISER DIAGRAM - FLOORS 3&4
SCALE: NONE
FIRE SUPPRESSION LEGEND
RESIDENTIAL OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
ORDINARY HAZARD OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
SPRINKLER / STANDPIPE RISER
FIRE DEPARTMENT CONNECTION
BACKFLOW PREVENTER FLOW TEST HEADER
DOUBLE CHECK BACKFLOW PREVENTER
ABOVE GROUND SPRINKLER PIPING
BELOW GROUND SPRINKLER PIPING
PIPE BREAK / CONTINUATION
PIPE TURNED DOWN
PIPE TURNED UP
POST INDICATING VALVE (PIV)
OUTSIDE STEM & YOKE (OS&Y) VALVE
CHECK VALVE
STANDPIPE / HOSE VALVE
ORDINARY HAZARD OCCUPANCY W/
QUICK RESPONSE SPRINKLERS PER UFC 3-600-01
PENDENT SPRINKLER, RESIDENTIAL
PENDENT SPRINKLER, ORDINARY HAZARD QR
UPRIGHT SPRINKLER, RESIDENTIAL
UPRIGHT SPRINKLER, ORDINARY HAZARD QR
GENERIC VALVE
FLOOR CONTROL VALVE ASSEMBLY
SEISMIC LOOP
FIRE SUPPRESSION GENERAL NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.
2. ALL NEW FIRE PROTECTION PIPING, DEVICES, COMPONENTS, AND EQUIPMENT SHALL BE LISTED AND APPROVED
FOR USE IN AUTOMATIC FIRE PROTECTION SYSTEMS.
3. ALL NEW PIPING, VALVES AND EQUIPMENT SHALL BE LABELED AND PAINTED IN ACCORDANCE WITH THE
SPECIFICATIONS.
4. DESIGN INTENT IS FOR NEW SUPPLY MAIN PIPING BETWEEN THE BACKFLOW PREVENTER AND SPRINKLER/
STANDPIPE RISERS TO BE INSTALLED IN THE GROUND FLOOR UTILIDOR (BELOW FLOOR), AND FOR ALL SPRINKLER MAINS DOWNSTREAM OF THE FLOOR CONTROL VALVES TO BE INSTALLED ABOVE CEILINGS AND BELOW STRUCTURAL BEAMS. SPRINKLER BRANCH PIPING FROM CORRIDORS INTO DWELLING UNITS OR OTHER SPACES SHALL BE INSTALLED ABOVE CEILINGS AND BELOW STRUCTURAL BEAMS WHERE POSSIBLE, OR THROUGH EXISTING WALL/BEAM PENETRATIONS OF CORRIDOR WALLS ABOVE CEILINGS. CONTRACTOR SHALL NOT CORE DRILL ANY CONCRETE BEAM OR OTHER STRUCTURAL ELEMENT WITHOUT PRIOR COORDINATION AND APPROVAL
OF STRUCTURAL.
5. PROVIDE NEW AUTOMATIC WET PIPE FIRE SPRINKLER SYSTEM THROUGHOUT THE BUILDING, INCLUDING ALL VALVES, COMPONENTS, EQUIPMENT, ETC. NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM IN ACCORDANCE WITH UFC 3-600-01 (10 MAY 2019), NFPA 13R (2019), NFPA 13 (2019, AS REFERENCED BY NFPA 13R), AND PROJECT SPECIFICATIONS. SPRINKLERS SHALL BE INSTALLED THROUGHOUT ALL AREAS OF THE BUILDING EXCEPT AS PERMITTED BY NFPA 13R, PARAGRAPHS 6.6.2 THROUGH 6.6.7, SUMMARIZED BELOW.
5.1. SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS NOT LARGER THAN 5.1 SQ. M (55 SQ. FT.).
5.2. SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES WITHIN
DWELLING UNITS WHERE THE AREA OF THE SPACE IS NOT LARGER THAN 2.2 SQ. M (24 SQ. FT.) AND WHERE THE WALLS AND CEILINGS ARE SURFACED WITH NON-COMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIALS.
5.3. SPRINKLERS SHALL NOT BE REQUIRED IN CRAWL SPACES, UTILIDORS, FLOOR/CEILING SPACES, OR OTHER CONCEALED SPACES NOT INTENDED FOR LIVING PURPOSES OR STORAGE AND NOT CONTAINING FUEL
BURNING EQUIPMENT.
5.4. SPRINKLERS SHALL BE REQUIRED IN ANY CLOSET USED FOR HEATING OR AIR-CONDITIONING EQUIPMENT, WASHERS, DRYERS, OR WATER HEATERS.
5.5. SPRINKLERS SHALL BE REQUIRED AT THE TOP OF EACH STAIRWELL AND BELOW THE LOWEST ACCESSIBLE
LANDING IN ACCORDANCE WITH NFPA 13, 9.3.4.2.
6. PROVIDE MANUAL WET CLASS I STANDPIPE AND HOSE VALVE SYSTEM IN EACH OF THREE EXIT STAIRS IN ACCORDANCE WITH UFC 3-600-01 AND NFPA 14 (2019). NEW RISERS SHALL UTILIZE SAME EXISTING FLOOR PENETRATIONS AS DEMOLISHED RISERS, ENLARGE PENETRATIONS AS REQUIRED FOR NEW PIPING.
7. PRESSURE REQUIREMENTS OF THE STANDPIPE SYSTEM SHALL BE MET BY THE RESPONDING FIRE DEPARTMENT PUMPER TRUCK THROUGH THE BUILDING FIRE DEPARTMENT CONNECTION AS PERMITTED BY UFC 3-600-01, PARA.
9-10.1.
8. RESIDENTIAL AREAS INCLUDE DWELLING UNITS, CORRIDORS, RESTROOMS, LOUNGES, DAY ROOMS, AND SIMILAR
AREAS. LISTED RESIDENTIAL SPRINKLERS SHALL BE USED IN ALL RESIDENTIAL AREAS.
9. ORDINARY HAZARD AREAS INCLUDE MECHANICAL / ELECTRICAL EQUIPMENT ROOMS, STORAGE ROOMS, LAUNDRY ROOMS, JANITOR CLOSETS, AND SIMILAR AREAS. LISTED RESIDENTIAL SPRINKLERS SHALL BE USED IN ORDINARY HAZARD AREAS SMALLER THAN 46 SQ. M (500 SQ. FT.), AS PERMITTED BY NFPA 13R PARAGRAPH 7.2.4.1. LISTED QUICK RESPONSE SPRINKLERS, K-115 (8.0) MINIMUM, SHALL BE USED IN ALL ORDINARY HAZARD AREAS LARGER THAN 46 SQ. M (500 SQ. FT.). EXTENDED COVERAGE SPRINKLERS SHALL NOT BE PERMITTED.
10. ALL SPRINKLERS SHALL BE ORDINARY TEMPERATURE RATED UNLESS OTHERWISE REQUIRED BY NFPA 13 OR 13R.
11. CONTRACTOR SHALL CONDUCT WATER SUPPLY FLOW TESTING IN ACCORDANCE WITH NFPA 291 PRIOR TO
BEGINNING WORK TO VERIFY WATER SUPPLY DATA PROVIDED ON THE DRAWINGS. IF FLOW TEST INDICATES GREATER WATER SUPPLY THAN THAT PROVIDED, CONTRACTOR SHALL BASE DESIGN ON FLOW TEST DATA PROVIDED ON THE DRAWINGS. IF FLOW TEST INDICATES LESSER WATER SUPPLY THAN THAT PROVIDED, COORDINATE WITH CONTRACTING OFFICER.
12. ALL ABOVE GROUND PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE FOR WELDED, THREADED, OR GROOVED FITTINGS ONLY, EXCEPT PIPING LARGER THAN 50 mm (2 IN.) MAY BE SCHEDULE 10 FOR ROLLED GROOVE OR
WELDED FITTINGS ONLY.
13. PROVIDE FLOOR CONTROL VALVE ASSEMBLY, TO INCLUDE INDICATING CONTROL VALVE WITH SUPERVISORY SWITCH, SWING CHECK VALVE, WATERFLOW SWITCH, TEST AND DRAIN ASSEMBLY, AND PRESSURE GAUGES AT
EACH FLOOR AND WHERE SHOWN ON THE DRAWINGS.
14. PROVIDE SUPERVISORY TAMPER SWITCH ON ALL SPRINKLER CONTROL VALVES. CONNECT ALL FIRE ALARM
DEVICES (SUPERVISORY AND WATERFLOW SWITCHES) TO NEW FIRE ALARM SYSTEM.
15. PROVIDE AUXILIARY DRAINS IN ACCORDANCE WITH NFPA 13. ALL DRAINS SHALL BE PIPED TO THE OUTSIDE AND SHALL BE PROVIDED WITH APPROPRIATE SPLASH PROTECTION WHERE DRAINS DO NOT DISCHARGE ONTO PAVED SURFACE. DRAINS SHALL NOT DISCHARGE DIRECTLY INTO PEDESTRIAN OR VEHICLE PATHWAYS.
16. PIPING SERVING A SINGLE SPRINKLER SHALL BE 25 mm (1 IN.) MINIMUM.
17. PIPING SHOWN IS DIAGRAMMATIC AND SHOWN ONLY FOR THE PURPOSES OF VERIFYING THE WATER SUPPLY.
CONTRACTOR SHALL PROVIDE COMPLETE SYSTEM DESIGN, INCLUDING FINAL PIPE SIZING, HYDRAULIC CALCULATIONS AND WORKING PLANS IN ACCORDANCE WITH UFC 3-600-01 AND NFPA 13R. HYDRAULIC CALCULATIONS SHALL INCLUDE A MINIMUM PRESSURE LOSS OF 55 KPA (8 PSI) ACROSS THE BACKFLOW
PREVENTER.
18. PROVIDE AUTOMATIC AIR RELEASE AT HIGH POINT OF EACH SPRINKLER / STANDPIPE RISER PER NFPA 13, PIPE
DRAIN TO BUILDING EXTERIOR OR NEAREST SYSTEM DRAIN.
19. PROVIDE AUTOMATIC PRESSURE RELIEF VALVE DOWNSTREAM OF EACH CHECK VALVE PER NFPA 13, PIPE DRAIN
TO BUILDING EXTERIOR OR NEAREST SYSTEM DRAIN.
20. COORDINATE PIPE ROUTING WITH EXISTING CONDITIONS AND OTHER TRADES PRIOR TO INSTALLATION. PIPING
SHALL NOT BE INSTALLED ABOVE ELECTRICAL PANELS AND EQUIPMENT PER NFPA 70.
21. SUPPORT ALL PIPING FROM STRUCTURE IN ACCORDANCE WITH UFC 3-310-04, NFPA 13, AND PROJECT
SPECIFICATIONS.
22. PROVIDE SEISMIC BRACING AND ISOLATION IN ACCORDANCE WITH UFC 3-310-04, NFPA 13, AND PROJECT
SPECIFICATIONS.
23. PROVIDE MINIMUM 914 mm (3 FT.) CLEAR ACCESS AROUND ALL VALVES AND EQUIPMENT.
24. PERFORM ACCEPTANCE TESTING OF ALL SYSTEMS IN ACCORDANCE WITH NFPA 13 AND PROJECT
SPECIFICATIONS. FINAL ACCEPTANCE TESTS SHALL BE WITNESSED BY THE CONTRACTING OFFICER'S
DESIGNATED REPRESENTATIVE.
WATER SUPPLY ANALYSIS
1. FLOW TEST DATA
DATE OF FLOW TEST: 19 MARCH 2018
TESTED BY: CARLO VELASCO, SSGT, USAF
WITNESSED BY: SCOTT LEOPOLD, PE
TEST HYDRANT: C51, NEAR SOUTHEAST CORNER B538
FLOW HYDRANTS: C-31, NEAR SOUTHWEST CORNER B520
C-39, NEAR NORTHEAST CORNER B520
STATIC PRESSURE: 3.86 BAR (56 PSI)
RESIDUAL PRESSURE: 2.90 BAR (42 PSI)
MEASURED FLOW: 7836 LPM (2070 GPM)
CALCULATED FLOW: (13,056 LPM @ 1.38 BAR)
(3449 GPM @ 20 PSI)
2. SPRINKLER BASIS OF DESIGN:
RESIDENTIAL PENDENT TYCO TY2234, K=70.6 (4.9)
RESIDENTIAL CONCEALED TYCO TY3596, K=70.6 (4.9)
ORDINARY HAZARD TYCO TY4231, K=115 (8.0)
3. PRELIMINARY HYDRAULIC ANALYSIS
A. RESIDENTIAL - CORRIDOR
SPRINKLER FLOW 200 LPM (53 GPM)
TOTAL FLOW 1530 LPM (404 GPM)
PRESSURE AVAILABLE 3.8 BAR (55 PSI)
PRESSURE REQUIRED 3.1 BAR (45 PSI)
SAFETY FACTOR 0.7 BAR (10 PSI)
B. RESIDENTIAL - DWELLING UNIT
SPRINKLER FLOW 150 LPM (40 GPM)
TOTAL FLOW 1480 LPM (390 GPM)
PRESSURE AVAILABLE 3.8 BAR (55 PSI)
PRESSURE REQUIRED 3.1 BAR (45 PSI)
SAFETY FACTOR 0.7 BAR (10PSI)
C. RESIDENTIAL - LAUNDRY
SPRINKLER FLOW 241 LPM (64 GPM)
TOTAL FLOW 1571 LPM (415 GPM)
PRESSURE AVAILABLE 3.8 BAR (55 PSI)
PRESSURE REQUIRED 3.4 BAR (50 PSI)
SAFETY FACTOR 0.4 BAR (5 PSI)
D. ORDINARY HAZARD - MECH ROOM 010 + 5 ADJACENT DWELLING UNITS
SPRINKLER FLOW 1426 LPM (377 GPM)
TOTAL FLOW 2756 LPM (728 GPM)
PRESSURE AVAILABLE 3.7 BAR (54 PSI)
PRESSURE REQUIRED 3.5 BAR (51 PSI)
SAFETY FACTOR 0.2 BAR (3 PSI)
THE WATER SUPPLY IS ADEQUATE TO MEET THE SYSTEM DEMAND
REQUIREMENTS WITHOUT THE NEED FOR A WATER STORAGE TANK OR FIRE
PUMP.
4. PRESSURE REQUIREMENTS OF THE MANUAL WET STANDPIPE SYSTEM WILL BE
MET BY THE LOCAL RESPONDING FIRE DEPARTMENT PUMPER TRUCK THROUGH
THE BUILDING FIRE DEPARTMENT CONNECTION (10.3 BAR [150 PSI] SUPPLIED AT
THE FIRE DEPARTMENT CONNECTION) AS PERMITTED BY UFC 3-600-01, PARA.
9-10.1 .
STANDPIPE FLOW 3800 LPM (1000 GPM)
PRESSURE AVAILABLE 10.3 BAR (150 PSI)
PRESSURE REQUIRED 9.7 BAR (140 PSI)
SAFETY FACTOR 0.6 BAR (10 PSI)
150mm FIRE SERVICE LINE, SEE CIVIL FOR CONT
PIV (SEE CIVIL)
150mm DOUBLE CHECK
BACKFLOW PREVENTER
BACKFLOW PREVENTER
TEST HEADER
FIRE DEPT. CONNECTION
STANDPIPE HOSE VALVE
AT MAIN STAIR LANDING
SPRINKLER FLOOR CONTROL
VALVE ASSEMBLY
WEST STAIR TOWER
CENTRAL STAIR TOWER
100 150 100
0 10
INDICATING CONTROL
VALVE W/TAMPER SWITCH
EAST STAIR TOWER
AUTOMATIC AIR RELEASE VALVE,
PIPE TO DRAIN OR TO OUTSIDE (TYP)
FIRE SPRINKLER DESIGN CRITERIA:
1. RESIDENTIAL AREAS / RESIDENTIAL SPRINKLERS:
REFERENCE NFPA 13R: 6.2.2, 7.1, 7.2.2 AND 7.2.4
MINIMUM SPRINKLER PRESSURE 0.48 BAR (7 PSI)
DISCHARGE SPRAY DENSITY 2.04 mm/MIN/SQ. M (0.05 GPM/SQ. FT.)
DESIGN AREA ALL SPRINKLERS WITHIN A COMPARTMENT, MAXIMUM OF 4 SPRINKLERS
2. ORDINARY HAZARD AREAS < 46 SQ. M (500 SQ. FT.) / RESIDENTIAL SPRINKLERS
REFERENCE NFPA 13R: 7.2.3.1 AND 7.2.4.1
MINIMUM SPRINKLER PRESSURE 0.48 BAR (7 PSI)
DISCHARGE SPRAY DENSITY 8 mm/MIN/SQ. M (0.20 GPM/SQ. FT.)
DESIGN AREA ALL SPRINKLERS WITHIN A COMPARTMENT, MAXIMUM OF 4 SPRINKLERS
3. ORDINARY HAZARD AREAS > 46 SQ. M (500 SQ. FT.) / QUICK RESPONSE SPRINKLERS
REFERENCE UFC 3-600-01: TABLE 9-3
MINIMUM SPRINKLER PRESSURE 0.48 BAR (7 PSI)
MINIMUM K-FACTOR 115 (8.0)
DISCHARGE SPRAY DENSITY 8 mm/MIN/SQ. M (0.20 GPM/SQ. FT.)
DESIGN AREA 230 SQ. M (2500 SQ. FT.)
S.
L
EO
PO
LD
SV
L
SW
D
FP001
FI
R
E
SU
PP
R
ES
SI
O N
G
EN
ER
AL
N O
TE
S
AN
D
L
EG
EN
D
S
FIRE PROTECTION PIPING SCHEMATIC
SCALE: NONE
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
ATC
H
LIN
E M
ATC
H
LIN
E
CORRIDOR 1
C1
FACP RM
LOBBY
RRM 1
RR1
UNIT 106
UNIT 104
UNIT 102
UNIT 101
UNIT 103
UNIT 105
UNIT 107
UNIT 109
UNIT 111
UNIT 113
UNIT 108
UNIT 110
UNIT 112
UNIT 114
LINEN 1
MECHANICAL RM
DAY ROOM 1
LG1
CORRIDOR 1W
C1W
JANITOR 1
J1
LAUNDRY 1
LD1
UNIT 123
UNIT 121
UNIT 119
STORAGE 1
ST1
UNIT 124
STAIR 1
S1
STAIR 2
S2
150mm FIRE SERVICE LINE, SEE CIVIL FOR CONT.
FIRE DEPT.
CONNECTION
150mm DOUBLE CHECK
BACKFLOW PREVENTER
SPRINKLER MAIN DOWN
TO UTILIDOR
ROUTE PIPING BELOW FLOOR IN
UTILIDOR TO SPRINKLER/STANDPIPE
RISERS IN STAIRWELLS
100mm SPRINKLER/
STANDPIPE RISER
BFP TEST
HEADER
SPRINKLER MAIN ABOVE
CORRIDOR CEILING
150 100100100 100
COORD W/ARCH FOR
HOSE VALVE CABINET
100mm STANDPIPE RISER, ROUTE
PIPING UP THROUGH EXISTING
FLOOR PENETRATIONS
100 100 75 757575
253025
253025
DESIGN AREA D,
ORDINARY HAZARD
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M
ATC
H
LIN
E
S3
STAIR 3
UNIT 130
UNIT 128
UNIT 126
UNIT 136
UNIT 135
UNIT 134
UNIT 133
UNIT 125
UNIT 127
UNIT 129
UNIT 132
UNIT 131
C1E
CORRIDOR 1E
100mm STANDPIPE RISER, ROUTE
PIPING UP THROUGH EXISTING
FLOOR PENETRATIONS
SPRINKLER MAIN ABOVE
CORRIDOR CEILING
100 100
ROUTE PIPING BELOW FLOOR IN
UTILIDOR TO SPRINKLER/STANDPIPE
RISERS IN STAIRWELLS
75 75 75
25 25
DESIGN AREA D,
ORDINARY HAZARD
A
B
C
D
E
F
FIRE SUPPRESSION LEGEND
RESIDENTIAL OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
ORDINARY HAZARD OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
ORDINARY HAZARD OCCUPANCY W/
QUICK RESPONSE SPRINKLERS PER UFC 3-600-01
S.
L
EO
PO
LD
SV
L
SW
D
FP101
FI
R
E
SU
PP
R
ES
SI
O N
P
LA
N
FI
R
ST
F
LO
O
R
KEYNOTES
1 FLOOR CONTROL VALVE ASSEMBLY, SEE DETAIL 2/FP-501.
INSTALL VALVES TIGHT TO WALL ABOVE HOSE VALVE
CABINET APPROX. 2130 mm ABOVE FLOOR LEVEL. INSTALL
PIPING DOWNSTREAM OF CONTROL VALVE TO MAINTAIN
MINIMUM CLEAR HEADROOM OF 2030 mm. DO NOT ROUTE
PIPING ABOVE ELECTRICAL PANELS PER NFPA 70.
FIRE SUPPRESSION PLAN - FIRST FLOOR
SCALE: 1:100 0 1000 3000 70000 1000 3000 7000
2 SPRINKLER DRAIN, PIPE THROUGH WALL ABOVE FLOOR
AND DISCHARGE TO EXTERIOR. PROVIDE 45° TURNED
DOWN ELBOW AND SPLASH PROTECTION AT DISCHARGE.
DRAIN TO BE MINIMUM ONE PIPE SIZE LARGER THAN
LARGEST CONNECTED SECTIONAL DRAIN.
PLAN
NORTH
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
R G
3 STANDPIPE CONTROL VALVE WITH TAMPER SWITCH
LOCATED BELOW FLOOR IN UTILIDOR.
4 PROVIDE CONTROL VALVE WITH TAMPER SWITCH IN
STAIRWELL AT BASE OF STANDPIPE BELOW FIRST HOSE
VALVE.
ATC
H
LIN
E M
ATC
H
LIN
E
CORRIDOR 2
C2
JANITOR 2
J2
UNIT 213
UNIT 211
UNIT 209
UNIT 207
UNIT 205
UNIT 203
UNIT 201
UNIT 202
UNIT 204
UNIT 206
UNIT 208
UNIT 210
UNIT 212
UNIT 214
UNIT 216
216 LAUNDRY 2
LD2
LOUNGE 2
LG2
CORRIDOR 2W
C2W
STORAGE 2
ST2
UNIT 218
UNIT 219
UNIT 222
UNIT 224
UNIT 221
UNIT 223
STAIR 1
S1
STAIR 2
S2
UNIT 225
UNIT 226
100mm SPRINKLER/
STANDPIPE RISER
SPRINKLER MAIN ABOVE
CORRIDOR CEILING
100mm STANDPIPE RISER, ROUTE PIPING THROUGH
EXISTING FLOOR PENETRATIONS
COORD W/ARCH FOR
HOSE VALVE CABINET
75 75 75 75 75
25 25
100mm STANDPIPE RISER, ROUTE PIPING
THROUGH EXISTING FLOOR PENETRATIONS
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M
ATC
H
LIN
E
S3
STAIR 3
UNIT 233
UNIT 231
UNIT 229
UNIT 227
UNIT 225
UNIT 232
UNIT 230
UNIT 228
UNIT 226
UNIT 236
UNIT 234
UNIT 235
C2E
CORRIDOR 2E
SPRINKLER MAIN ABOVE
CORRIDOR CEILING
75 75 75
A
B
C
D
E
F
FIRE SUPPRESSION LEGEND
RESIDENTIAL OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
ORDINARY HAZARD OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
S.
L
EO
PO
LD
SV
L
SW
D
FP102
FI
R
E
SU
PP
R
ES
SI
O N
P
LA
N
SE
C
O N
D F
LO
O
R
FIRE SUPPRESSION PLAN - SECOND FLOOR
SCALE: 1:100
PLAN
NORTH
0 1000 3000 70000 1000 3000 7000
KEYNOTES
1 FLOOR CONTROL VALVE ASSEMBLY, SEE DETAIL 2/FP-501.
INSTALL VALVES TIGHT TO WALL ABOVE HOSE VALVE
CABINET APPROX. 2130 mm ABOVE FLOOR LEVEL. INSTALL
PIPING DOWNSTREAM OF CONTROL VALVE TO MAINTAIN
MINIMUM CLEAR HEADROOM OF 2030 mm. DO NOT ROUTE
PIPING ABOVE ELECTRICAL PANELS PER NFPA 70.
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
ATC
H
LIN
E M
ATC
H
LIN
E
CORRIDOR 3
C3
JANITOR 3
J3
UNIT 313
UNIT 311
UNIT 309
UNIT 307
UNIT 305
UNIT 303
UNIT 301
UNIT 302
UNIT 304
UNIT 306
UNIT 308
UNIT 310
UNIT 312
UNIT 314
UNIT 316
316 LAUNDRY 3
LD3
CORRIDOR 3W
C3W
STORAGE 3
ST3
LOUNGE 3
LG3
UNIT 322
UNIT 324
UNIT 323
UNIT 321
UNIT 319
UNIT 318
STAIR 1
S1
STAIR 2
S2
UNIT 325
UNIT 326
100mm SPRINKLER/
STANDPIPE RISER
SPRINKLER MAIN ABOVE
CORRIDOR CEILING
100mm STANDPIPE RISER, ROUTE PIPING THROUGH
EXISTING FLOOR PENETRATIONS
COORD W/ARCH FOR
HOSE VALVE CABINET
75 75 75 75 75
25 25
100mm STANDPIPE RISER, ROUTE PIPING
THROUGH EXISTING FLOOR PENETRATIONS
SPRINKLER MAIN ABOVE
CORRIDOR CEILING
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M
ATC
H
LIN
E
S3
STAIR 3
UNIT 333
UNIT 332
UNIT 330
UNIT 331
UNIT 325
UNIT 327
UNIT 329
UNIT 328
UNIT 326
UNIT 334
UNIT 335
UNIT 336
C3E
CORRIDOR 3E75 75 75
A
B
C
D
E
F
FIRE SUPPRESSION LEGEND
RESIDENTIAL OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
ORDINARY HAZARD OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
S.
L
EO
PO
LD
SV
L
SW
D
FP103
FI
R
E
SU
PP
R
ES
SI
O N
P
LA
N
TH
IR
D F
LO
O
R
FIRE SUPPRESSION PLAN - THIRD FLOOR
SCALE: 1:100
PLAN
NORTH
0 1000 3000 70000 1000 3000 7000
KEYNOTES
1 FLOOR CONTROL VALVE ASSEMBLY, SEE DETAIL 2/FP-501.
INSTALL VALVES TIGHT TO WALL ABOVE HOSE VALVE
CABINET APPROX. 2130 mm ABOVE FLOOR LEVEL. INSTALL
PIPING DOWNSTREAM OF CONTROL VALVE TO MAINTAIN
MINIMUM CLEAR HEADROOM OF 2030 mm. DO NOT ROUTE
PIPING ABOVE ELECTRICAL PANELS PER NFPA 70.
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
ATC
H
LIN
E M
ATC
H
LIN
E
S2
STAIR 2
S1
STAIR 1
LG4
DAY ROOM 4
UNIT 418
UNIT 419
UNIT 423
ST4
STORAGE 4
UNIT 422
UNIT 424
UNIT 416
UNIT 414
UNIT 412
UNIT 410
UNIT 408
UNIT 406
UNIT 404
UNIT 402
UNIT 401
UNIT 403
UNIT 405
UNIT 407
UNIT 409
UNIT 411
UNIT 413
LD4
LAUNDRY 4
J4
JANITOR 4
UNIT 421
C4
CORRIDOR 4
C4W
CORRIDOR 4W
RR4
RRM 4
UNIT 425
UNIT 426
SPRINKLER MAIN ABOVE
CORRIDOR CEILING
100mm STANDPIPE RISER, ROUTE PIPING THROUGH
EXISTING FLOOR PENETRATIONS
100mm SPRINKLER/
STANDPIPE RISER
COORD W/ARCH FOR
HOSE VALVE CABINET
25 25
75 75 75 75 75
25 (TYP)
DESIGN AREA B,
RESIDENTIAL / DWELLING UNIT
DESIGN AREA A,
RESIDENTIAL / CORRIDOR
DESIGN AREA C,
RESIDENTIAL / LAUNDRY
100mm STANDPIPE RISER, ROUTE PIPING
THROUGH EXISTING FLOOR PENETRATIONS
SPRINKLER MAIN ABOVE
CORRIDOR CEILING
M
ATC
H
LIN
E
A
14 15 16 17 18 19 20
B
C
D
E
F
14'
M
ATC
H
LIN
E
S3
STAIR 3
UNIT 425
UNIT 434
UNIT 426
UNIT 428
UNIT 430
UNIT 432
UNIT 427
UNIT 429
UNIT 431
UNIT 433
UNIT 435
C4E
CORRIDOR 4E
UNIT 436
75 75 75
A
B
C
D
E
F
FIRE SUPPRESSION LEGEND
RESIDENTIAL OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
ORDINARY HAZARD OCCUPANCY W/
RESIDENTIAL SPRINKLERS PER NFPA 13R
S.
L
EO
PO
LD
SV
L
SW
D
FP104
FI
R
E
SU
PP
R
ES
SI
O N
P
LA
N
FO
U
R
TH
F
LO
O R
FIRE SUPPRESSION PLAN - FOURTH FLOOR
SCALE: 1:100
PLAN
NORTH
0 1000 3000 70000 1000 3000 7000
KEYNOTES
1 FLOOR CONTROL VALVE ASSEMBLY, SEE DETAIL 2/FP-501.
INSTALL VALVES TIGHT TO WALL ABOVE HOSE VALVE
CABINET APPROX. 2130 mm ABOVE FLOOR LEVEL. INSTALL
PIPING DOWNSTREAM OF CONTROL VALVE TO MAINTAIN
MINIMUM CLEAR HEADROOM OF 2030 mm. DO NOT ROUTE
PIPING ABOVE ELECTRICAL PANELS PER NFPA 70.
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
FLOOR LEVEL
TO SPRINKLERS
65mm FIRE HOSE VALVE AT
EACH MAIN STAIR LANDING
100mm SPRINKLER /
STANDPIPE RISER
DRAIN RISER, ONE PIPE SIZE
LARGER THAN LARGEST
CONNECTED DRAIN. PIPE TO
OUTSIDE AT GROUND FLOOR.
FLOOR LEVEL
SIGHT GLASS
3-POSITION TEST AND DRAIN
VALVE WITH INTEGRAL ORIFICE
AND PRESSURE RELIEF,
PIPE RELIEF TO DRAIN
PRESSURE GAUGE W/GAUGE
COCK (TYP)
WATERFLOW SWITCH
SWING CHECK VALVE
INDICATING CONTROL VALVE
W/VALVE SUPERVISORY
(TAMPER) SWITCH
FL
O
W
0m m
FLOW
150mm FIRE SERVICE TO BUILDING, SEE DETAIL 7/FP501
DUCTILE IRON FLANGE
FINISHED FLOOR
PIPE TIE-RODS W/CLAMPS,
NUTS AND WASHERS
DUCTILE IRON BELL & SPIGOT PIPE
W/MECHANICAL JOINT FITTINGS
CONCRETE THRUST BLOCK,
SEE CIVIL FOR DETAILS
CORE DRILL FOUNDATION WALL MINIMUM
50mm LARGER THAN PIPE SIZE. FILL VOID
SPACE W/CONTINUOUS LINK-SEAL
REINFORCED NEOPRENE COMPRESSION
TYPE WATERPROOFING ASSEMBLY
FINISHED GRADE
EXTERIOR BUILDING WALL
150mm FIRE SERVICE SUPPLY
MAIN, SEE CIVIL FOR CONT.
THREADED ROD COUPLING
END OF BRANCH LINE SURGE RETAINER CLIP
CONTINUOUS ALL THREAD ROD (TYP)
ADJUSTABLE RING HANGER
CONCRETE ANCHOR
CONCRETE FLOOR/ROOF
ASSEMBLY
PROVIDE SECOND RESTRAINT IN
OPPOSITE DIRECTION WHERE REQUIRED
45° MIN. SWAY BRACE FITTING
SHEDULE 40 PIPE OR EQUIVALENT
PIPE CLAMP
NOTE: CONTRACTOR SHALL DESIGN AND INSTALL ALL BRACING IN
CONCRETE ANCHOR
CONCRETE FLOOR/ROOF
ASSEMBLY
NOTE: CONTRACTOR SHALL DESIGN AND INSTALL ALL BRACING IN
CONCRETE ANCHOR
SWAY BRACE FITTING
PIPE CLAMP
SCHEDULE 40 PIPE OR EQUIVALENT
SPRINKLER PIPE
CONCRETE FLOOR/ROOF
ASSEMBLY
65mm HOSE VALVE W/
CAP AND CHAIN
150mm x 350mm
FLANGE, CLASS 250
PATTERN150mm SCH. 40 PIPE
150mm WELDED CAP
65mm FIRE HOSE VALVE
W/CAP AND CHAIN, TYP.
150mm WELDED CAP
SIDE VIEW
TOP VIEW
150 TO BELOW
FLOOR UTILIDOR
OS&Y CONTROL VALVE
W/SUPERVISORY SWITCH (TYP)
150mm DOUBLE CHECK
BACKFLOW PREVENTER
150mm UNDERGROUND
FIRE SERVICE LINE,
SEE DETAIL 1/FP501
FLOOR
TO BFP TEST
HEADER
TO FDC
FDC CHECK VALVE
W/AUTOMATIC DRIP CHECK
OS&Y CONTROL VALVE,
NORMALLY CLOSED
BLIND FLANGE
S.
L
EO
PO
LD
SV
L
SW
D
FP501
FI
R
E
SU
PP
R
ES
SI
O N
D
ET
AI
LS
FIRE SERVICE ENTRANCE DETAIL
SCALE: NONE 2
FLOOR CONTROL VALVE ASSEMBLY DETAIL
SCALE: NONE
TYPICAL END HEAD RESTRAINT DETAIL
SCALE: NONE 4
TYPICAL LATERAL SWAY BRACE DETAIL
SCALE: NONE 5
TYPICAL LONGITUDINAL SWAY BRACE DETAIL
SCALE: NONE
BFP TEST HEADER DETAIL
SCALE: NONE 7
FIRE SPRINKLER RISER DETAIL
SCALE: NONE 210
R
EP
A
IR
D O
R M
, B
M
IS
A
W A
A
IR
B A
SE
JA
PA
N
(Q
KK
A1
2)
FA
-1
8- F-
JU
N
E
, 2
SHEET
IDENTIFICATION
D
ES
IG
N
ED
B
Y:
D W
N B
Y:
C
KD
B
Y:
SO
LI
C
IT
AT
IO
N
N O
D
AT
E:
C O
N
TR
AC
T
N O
SU
BM
IT
TE
D
B Y:
U .S
. A
IR
F O
R C
E C
IV
IL
E N
G
IN
EE
R
C
EN
TE
R
O
TI
E R
S& H
J O
IN
T
VE
N
TU
R
E
N
. M
AY
FA
IR
R O
AD
S
U
IT
E
M
IL
W
AU
KE
E, W
I 5
A
B
C
D
1 2 3 4 5
M A
R K
D
ES
C R
IP
TI
O N
D A
TE
FINAL DESIGN
SIGNED
THIS WORK WAS PREPARED
BY ME OR UNDER MY
SUPERVISION
SHEET OF 232
PA
U
L
VA
N D
EN
BE
| FD101_FIRST FLOOR FIRE PROTECTION DEMO PLAN-Layout1 |
| FD102_SECOND FLOOR FIRE PROTECTION DEMO PLAN-Layout1 |
| FD103_THIRD FLOOR FIRE PROTECTION DEMO PLAN-Layout1 |
| FD104_FOURTH FLOOR FIRE PROTECTION DEMO PLAN-Layout1 |
| FA001_FIRE ALARM GENERAL NOTES & LEGENDS-Layout1 |
| FA101_FIRST FLOOR FIRE ALARM PLAN-Layout1 |
| FA102_SECOND FLOOR FIRE ALARM PLAN-Layout1 |
| FA103_THIRD FLOOR FIRE ALARM PLAN-Layout1 |
| FA104_FOURTH FLOOR FIRE ALARM PLAN-Layout1 |
| FA501_FIRE ALARM DETAILS-Layout1 |
| FA601_FIRE ALARM RISER DIAGRAM - FLOORS 1&2-Layout1 |
| FA602_FIRE ALARM RISER DIAGRAM - FLOOR 3&4-Layout1 |
| FP101_FIRST FLOOR FIRE SUPPRESSION PLAN-Layout1 |
| FP102_SECOND FLOOR FIRE SUPPRESSION PLAN-Layout1 |
| FP103_THIRD FLOOR FIRE SUPPRESSION PLAN-Layout1 |
| FP104_FOURTH FLOOR FIRE SUPPRESSION PLAN-Layout1 |
| FP501_FIRE SUPPRESSION DETAILS-Layout1 |
File details come from the government source that posted it. Updated .