Atch 2_Draft Drawing 09 EMCS - Repair Dorm B542.pdf

PDF 5 MB Posted

Attached to
Project No. QKKA 171042, Repair Dorm Bldg. 542, Misawa Air Base, Japan
Solicitation number
FA520522R0001
Issued by

About this file

This pre-solicitation notice seeks proposals for the repair of Dormitory Building 542 at Misawa Air Base in Japan. The contractor shall provide renovation services including interior demolition, hazardous material abatement, structural and architectural improvements, new electrical and plumbing systems, telecommunications installation, energy management controls, fire protection, and civil site work. The performance period is expected to be 531 calendar days including 30 days for mobilization. The estimated price range for the contract is between $10,000,000 and $25,000,000. The solicitation is anticipated for issuance on January 31, 2022 with proposals due approximately 40 days thereafter. A pre-proposal conference and site visit will be held on February 25, 2022 to explain the RFP requirements and allow examination of project sites. The award will be made to the offeror providing the best value using a subjective tradeoff process, evaluating past performance and price. The contract type will be firm-fixed price. Interested offerors must be authorized to operate in Japan and obtain necessary licenses to comply with host government laws.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EM001

EM

C

S N

O

TE

S, S

YM

BO

LS

A

N D

A

BB

R

EV

IA

TI

O N

S

EMCS CABINET

H HANDHOLE

ASPHALT REPAIR

CONCRETE REPAIR

AC

X

HEAT PUMP (OUTDOOR

UNIT)

CEILING CASSETTE HEAT

PUMP

HP

X

CEILING ACCESS PANEL

AC

X CEILING HEAT PUMP

T THERMOSTAT

K.

H

EL

BI

G

KR

H

AT

W

1. THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING

CONDITIONS AND SHALL NOTIFY THE CONTRACTING OFFICER OF

ANY DISCREPANCIES, OMISSIONS, OR CONFLICTS PRIOR TO

COMMENCING WORK.

2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING

ALL DAMAGES TO EXISTING AREAS CAUSED BY THIS PROJECT TO

ORIGINAL CONDITION AS DIRECTED BY THE CONTRACTING OFFICER

/ REPRESENTATIVE AT NO ADDITIONAL COST TO THE GOVERNMENT.

3. PAINT ALL MARKS LEFT FROM REMOVAL OR RELOCATION OF

EQUIPMENT, DEVICES, AND RACEWAYS TO MATCH COLOR OF

ADJACENT SURFACES.

4. PAINT ALL EXTERIOR EXPOSED NEW EQUIPMENT INCLUDING;

CABINETS, ENCLOSURES, CONDUIT /RACEWAY, OUTLET BOXES AND

JUNCTION BOXES TO MATCH COLOR OF ADJACENT SURFACES.

5. COORDINATE SIZES OF CIRCUIT BREAKERS, WIRING, CONDUIT,

DISCONNECT SWITCHES, MOTOR STARTERS AND OTHER

ELECTRICAL ACCESSORIES WITH ACTUAL EQUIPMENT PROVIDED.

6. ELECTRICAL INSTALLATION SHALL COMPLY WITH 2017 NEC.

7. PROVIDE A SEPARATE INSULATED GREEN GROUND CONDUCTOR

SIZED IN ACCORDANCE WITH 2017 NEC TABLE 250.122 IN ALL

FEEDER AND BRANCH CIRCUIT RACEWAYS.

8. ALL WORK SHALL BE NEW UNLESS OTHERWISE INDICATED.

9. COORDINATE WORK WITH ALL TRADES AND SUB CONTRACTORS AS

APPLICABLE.

10. CONDUCTORS SHALL BE MINIMUM 3.5mm², UNLESS OTHERWISE

INDICATED.

11. CONDUCTOR SIZES SHOWN ARE THE MINIMUM ACCEPTABLE BASED

ON COPPER IN JAPANESE INDUSTRIAL STANDARD (JIS) SIZES.

12. DRAWINGS ARE SCHEMATIC ONLY. CONTRACTOR SHALL SUPPLY A

COMPLETE AND OPERABLE SYSTEM. CONTRACTOR TO DETERMINE

EXACT ROUTING OF POWER AND COMMUNICATIONS CONDUIT FOR A

COMPLETE AND OPERABLE SYSTEM. COORDINATE ROUTING WITH

MECHANICAL AND ARCHITECTURAL DISCIPLINES TO CONCEAL FROM

VIEW TO EXTENT POSSIBLE. ALL EQUIPMENT, CONDUIT, WIRING,

AND CABLES ARE TO BE INCLUDED.

13. ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED

OTHERWISE.

14. ALL EQUIPMENT SHALL BE LISTED FOR USE AT 50Hz.

15. SPECIFICATIONS ARE PART OF THE CONTRACT DOCUMENTS. SEE

SPECIFICATIONS FOR ADDITIONAL DETAILS.

16. IF EXTERIOR BUILDING NUMBERS ARE DAMAGED DURING

CONSTRUCTION, CONTRACTOR SHALL REPAINT THE NUMBER TO

MATCH EXISTING.

17. EACH BUILDING TYPE IS PROVIDED WITH DRAWINGS SHOWING

FLOOR PLANS AND ELEVATIONS. THE FLOOR PLANS DETAIL ALL

EQUIPMENT REQUIRED ON THE EXTERIOR OF THE BUILDING. THE

EQUIPMENT SHOWN ON THE ELEVATIONS ARE MEANT FOR

COORDINATION OF LARGE EQUIPMENT MOUNTED TO THE BUILDING

WALL. ELEVATIONS ARE NOT INCLUSIVE OF ALL EQUIPMENT TO BE

INSTALLED ON THE BUILDING AND THE FLOOR PLANS SHALL BE

REFERENCED FOR THIS INFORMATION.

18. PERFORMANCE AND VERIFICATION TESTING OF THE EMCS SYSTEM

IS REQUIRED PER SPECIFICATION 23 09 23.13 20. SPECIFICATION

SECTION CONTAINS REQUIREMENTS AND CHECKLISTS IN

COMPLIANCE WITH AFGM2017-32-01.

19. ALL EXTERIOR EXPOSED CONDUIT SHALL BE RIGID STEEL CONDUIT.

JIS C 8305. ALL UNDERGROUND CONDUIT SHALL BE FEP JIS C 3653.

20. ALL CONDUITS SHALL BE ATTACHED TO ANY ENCLOSURE VIA A

LISTED FITTING. DOUBLE LOCKNUTS ARE NOT ACCEPTABLE.

OUTDOOR CONDUIT CONNECTORS SHALL BE LISTED RAIN TIGHT.

CONNECTORS ON SIDE OF ENCLOSURE SHALL BE OF THREADED

HUB TYPE.

21. CONTRACTOR IS RESPONSIBLE FOR THE FIBER, CONDUIT

INSTALLATION, TERMINATION AND TESTING IN COMPLIANCE WITH

DRAWINGS AND SPECIFICATIONS.

22. CONTRACTOR RESPONSIBLE FOR REMOVAL AND REINSTALLATION

OF ALLIED TELESIS EQUIPMENT/ INFRASTRUCTURE.

23. CONTRACTOR TO PROVIDE DOCUMENTATION AND ANALYSIS OF

MECHANICAL SYSTEMS VALIDATING THAT ALL MECHANICAL

SYSTEMS OPERATE AS DESIGNED. CONTRACTOR IS RESPONSIBLE

TO NOTIFY THE BASE IMMEDIATELY IN WRITING IF DESIGNED

SYSTEMS DO NOT MEET MANUFACTURES OR SPECIFICATION

REQUIREMENTS.

24. ALL GROUNDING WIRES SHALL BE GREEN. ALL POWER WIRES SHALL

BE RED/BLACK. ALL NEUTRAL WIRES SHALL BE WHITE.

25. DASHBOARD SHALL BE FULLY INTEGRATED INTO EXISTING

SERVERS, NOT WITHSTANDING MINOR VARIATIONS IN SERVER

CONFIGURATIONS.

GENERAL PLAN NOTES: SYMBOL LEGEND

THERMOSTAT CABLE

M-NET CABLE BETWEEN OUTDOOR UNITS

EMCS

WATER METER CABLE. TWISTED PAIR CABLE.

M-NET CABLE BETWEEN INDOOR UNITS AND

OUTDOOR UNITS

TIA-485 MODBUS CABLE

CABLE LEGEND

P

W

POWER METER

EMCS CABINET

WATER METER

R E

P A

I R

D

O R

M

B

M I S

A W

A

A

B

A S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

TRIP RATING

FRAME RATING

POLES

14 AWG

12 AWG

10 AWG

8 AWG

6 AWG

4 AWG

2 AWG

1 AWG

1/0 AWG

2/0 AWG

3/0 AWG

4/0 AWG

250 KCMIL

300 KCMIL

400 KCMIL

500 KCMIL

600 KCMIL

2.0 3.5 5.5

AMERICAN

WIRE GAUGE

AWG

JIS NOMINAL

SIZE (mm²)

AMPACITY

AMPS

(NOTE 1)

CONDUCTOR SIZING

NOTES:

1. REFERENCE NFPA 70, 310.15 TABLE 310.15 (B)(16)

75°, COPPER CONDUCTORS, IV(TW), THW(HIV).

1/2" 3/4" 1"

1-1/4" 1-1/2"

2" 2-1/2"

3" 3-1/2"

4"

CONDUIT AND RACEWAY

CONVERSION

AMERICAN

CONDUIT

DIAMETER

CONDUIT

METRIC

DESIGNATOR

NOTES:

1. REFERENCE NFPA 70, CHAPTER 9, TABLE 4.

JIS RSC

G16 G22 G28 G36 G42 G54 G70 G82 G92

G104

JIS EMT

E19 E25 E31 E39 E51 E63 E75

PUMP

D DAMPER

DRAFT

EM002

EM

C

S

AR

C H

IT

EC

TU

R

E

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

GENERAL NOTES:

1. PROVIDE PATCH CABLE BETWEEN SWITCHES AND

PATCH PANELS AS REQUIRED.

2. HVAC CONTROL SYSTEM (EMCS) SHALL BE THE

PROPERTY OF THE USAF AT THE END OF THE PROJECT,

IN ITS ENTIRETY. THIS SHALL INCLUDE (BUT NOT

LIMITED TO) ALL PROGRAMMING AND SOFTWARE

LICENSES. CONTROLS CONTRACTOR SHALL PROVIDE

THE GOVERNMENT FULL AND UNRESTRICTED ACCESS

TO ALL ASPECTS OF THE EMCS HEAD-END AND

BACK-END. THERE SHALL NOT BE ANY ASPECT OF

EMCS THAT IS INACCESSIBLE TO THE GOVERNMENT.

3. CONTRACTOR SHALL PROVIDE ALL LABOR, TOOLS,

EQUIPMENT TO COORDINATE EXISTING FRONT END

FOR EMCS (B794). CONTRACTOR MUST COORDINATE IP

ADDRESS, GRAPHICS, POP UP ALARMS WITH USAF TO

ENSURE COMPLETE FUNCTIONALITY.

4. PROVIDE THE HIGHEST LEVEL OF GRAPHICS. TOP TIER

QUALITY AND SERVES AS A SUPPLEMENT TO THE

REQUIREMENTS PROVIDED IN THE BACNET SPECIFICATIONS.

THIS WAS A PREVIOUS PROJECT COMMENT AND WANTED TO

ADD AS A LESSONS LEARNED TO PREVENT REPEAT

QUESTION.ALL EMCS PROGRAMMING SHALL MATCH

EXISTING VERSION OF THE JACE SOFTWARE AND MATCH

THE TOP TIER QUALITY LEVEL OF GRAPHICS. GRAPHICS

SHALL INDICATE THE INDOOR / OUTDOOR UNIT THAT IS

ASSIGNED TO RIGHT EW-50E (PER ZONE)

KEYNOTES

1 PROVIDE SFP PATCH CABLE BETWEEN SWITCHES AND

PATCH PANELS AS REQUIRED. REFER TO EM401.

PATCH CABLE TO BE PROVIDED UNDER THIS CONTRACT.2

DORM 542

1ST FLOOR OFFICE

FIBER PATCH

PANEL (EXISTING)

12 PORT SWITCH 'CISCO9300'

(OR COORDINATED WITH IICS

PRIOR TO PURCHASE)

BACnet

BACnet/IP (CAT6)MEDIA

CONVERTER

BA

C ne t/I

P (F

IB

ER

EW-50E EW-50E EW-50E EW-50E EW-50E EW-50E EW-50E EW-50E

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

TTTT

T T T T

T T T T

T T T T

T T T T

T T T T

T T T T

T T T T

T T T T

T T T T T T T T

T T T T

T T T T

T T T T

T T T T

T T T T

T T T T

T T T T

T T T T

T T T T

TERMINAL BLOCK

DISTECH

ECLYPSE

DISTECH

EC-BOS 8

T E R M I N A L

B L O C K

(x1) WATER METER

PULSE

DOMESTIC HOT

WATER HEATING

SYSTEM AND

STEAM METER

DI, DO, AI, AO

(x1) ELECTRIC METER:

OMRON-KM-N2-FLK

MODBUS

DORM 542

MECHANICAL ROOM

3 PANELS

UNINTERRUPTIBLE

POWER SUPPLY (UPS)

DEDICATED 120V

GFCI RECEPTACLES

TO 120V AC IN PANEL "A"

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 7

ZONE 8

TO 120V AC IN PANEL "A"

M-NET (TYP)

M-NET (TYP)

M-NET (TYP) M-NET (TYP)

M-NET (TYP)

M-NET (TYP)

M-NET (TYP)M-NET (TYP)

M-NET (TYP)

MECH

ROOM

EMCS

EXISTING

ELECTRIC

METER

WATER

METER

1 WATER METER

CABLE

VERIFY WITH MANUFACTURER

REQUIREMENTS FOR ALL CABLE TYPES

ELECTRIC

METER CABLE

TO CS

NETWORK

PATCH

PANEL

(EXISTING)

EMCS PATCH PANEL

EMCS SWITCH

OUTDOOR

UNIT 1

INDOOR

UNIT 1

INDOOR

UNIT 2

INDOOR

UNIT 3

THERM-

OSTAT

THERM-

OSTAT

THERM-

OSTAT

SAME AS

UNIT 1

SAME AS

UNIT 1

SAME AS

UNIT 1

OUTDOOR

UNIT 2

OUTDOOR

UNIT 3

OUTDOOR

UNIT 4

NOTE:

ACTUAL NUMBER OF OUTDOOR AND INDOOR

UNITS MAY VARY. REFER TO DRAWINGS FOR

ACTUAL NUMBER OF UNITS. NO MORE THAN 50

INDOOR UNITS PER EW50-E.

SAME AS

UNIT 1

SAME AS

UNIT 1

SAME AS

UNIT 1

OUTDOOR

UNIT 5

OUTDOOR

UNIT 6

OUTDOOR

UNIT 7

SAME AS

UNIT 1

OUTDOOR

UNIT 7

TYPICAL

OF 8

ZONES

QUANTITIES

VARY PER

ZONE.

REFER TO

EM002.

ZONE 1

DHW

TANK

#1

TIC

TO DHW SUPPLY

FROM DCW SUPPLY

T

T

METER

INTEGRATOR

TIC

T

DCW SUPPLY

T

STEAM SUPPLY

COND. RETURN

T

TO DHW TANKHW RE-CIRC

T

TO DHW TANKHW RE-CIRC

MAIN

CONTROLLER

(ECLIPSE)

FACILITY

CONTROL

PROCESSOR

(DISTECH

EC-BOS 6AX)

COIN

(CEVLAN)

SWITCH

COIN

DHW

TANK

#2

TIC

T

T

TIC

T

T

STEAM SUPPLY

COND. RETURN

TO DHW SUPPLY

FROM DCW SUPPLY

DCW SUPPLY

PACKAGED AHU BACNET

COMMUNUCATION MODULE

ELECTRICAL

PANELSTEAM METER

LOCATED IN

MECHANICAL

ROOM

METER

INTEGRATOR

WATER METER

LOCATED IN

MECHANICAL

ROOM

WATER

LEVELS

WATER

LEVELS

ELECTRICAL

METER

INTEGRATED

WITH

ELECTRICAL

BY CONTRACTOR REFER TO

EM002 FOR REQUIREMENTS

EM

C

S

BL

O C

K D

IA

G

R

AM

SCALE:

EMCS BLOCK DIAGRAM

NONE1

THERMOSTAT CABLE

M-NET CABLE BETWEEN OUTDOOR UNITS

WATER METER CABLE. TWISTED PAIR CABLE.

VERIFY CABLE WITH WATER METER VENDOR AND

EC-BOS/IO-16 VENDOR

M-NET CABLE BETWEEN INDOOR UNITS AND

OUTDOOR UNITS

TIA-485 MODBUS CABLE

SYMBOL LEGEND:

FIBER OPTIC CABLE

EM003

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

SCALE:

EMCS DHW BLOCK DIAGRAM

NONE2

GENERAL NOTES

1. REFER TO M-403 AND M-501 FOR SEQUENCE OF OPERATIONS.

02 03 04 05 06 07 08 09 11 12 13 14

B

C

D

E

F

14'10

M

ATC

H

LIN

E

W

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

ACU

HP

ACU

HP

HP

1HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

1 HP

HP

HP

HP

HP

1 HP

HP

1HP

T TT T T T T

T TT T T T T

T T T

T

TO UNITS 202,

302, 402

TO UNITS 204,

304, 404

TO UNITS 206,

306, 406

TO UNITS 208,

308, 408

TO UNITS 210,

310, 410

TO UNITS 212,

312, 412

TO UNITS 214,

314, 414

TO UNITS 216,

316, 416 TO UNITS 218,

318, 418

TO LD2, LD3, LD4

TO UNITS 222,

322, 422

TO UNITS 224,

324, 424

TO UNITS 201,

301, 401

TO UNITS 203,

303 403

TO UNITS 205,

305, 405

TO UNITS 207,

307, 407

TO UNITS 209,

309, 409

TO UNITS 211,

311, 411

TO UNITS 213,

313, 413

TO UNITS 219,

319, 419

TO UNITS 221,

321, 421

TO UNITS 223,

323, 423

S2

STAIR 2

S1

STAIR 1

UNIT 124

ST1

STORAGE 1

UNIT 119

UNIT 121

UNIT 123

LD1

LAUNDRY 1

J1

JANITOR 1

C1W

CORRIDOR 1W

LG1

DAY ROOM 1

MECHANICAL RM

LINEN 1

UNIT 114

UNIT 112

UNIT 110

UNIT 108

UNIT 113

UNIT 111

UNIT 109

UNIT 107

UNIT 105

UNIT 103

UNIT 101

UNIT 102

UNIT 104

UNIT 106

RR1

RRM 1

LOBBY

FACP ROOM

C1

CORRIDOR 1

ZONE 1

EMCS

PANEL 1

S

DWH

J

ZONE 2 ZONE 3

ZONE 5 ZONE 6 ZONE 7

EMCS

PANEL 2

EMCS

PANEL 3

D 11 DD 11 DD 11 DD 1 D

1 D 1 D

D 11 DD 11 DD 11 DD 1 1 D

ZONE 3

D 1

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

ACU

ACU

ACU

ACU

ACU

ACU

ACU

1 ACU

ACU

ACU

ACU

ACU

ACU

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

HP

T T T T T T

T T T T T T

TO UNITS 226,

326, 426

TO UNITS 228,

328, 428 TO UNITS 230,

330, 430

TO UNITS 232,

332, 432 TO UNITS 234,

334, 434

TO UNITS 236,

336, 436

TO UNITS 225,

325, 425

TO UNITS 227,

327, 427

TO UNITS 229,

329, 429

TO UNITS 231,

331, 431

TO UNITS 233,

333, 433

TO UNITS 235,

335 435

S3

STAIR 3

UNIT 130

UNIT 128

UNIT 126

UNIT 136

UNIT 135

UNIT 134

UNIT 133

UNIT 125

UNIT 127

UNIT 129

UNIT 132

UNIT 131

C1E

CORRIDOR 1E

ZONE 3 ZONE 4

ZONE 7 ZONE 8

D 1 1 D

D 1 1 D

D 11 D

D 11 D

D 11 D

D 11 D

EM101

EL

EC

TR

IC

AL

P

LA

N

FI

R

ST

F

LO

O R

E M

C S

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

SCALE:

ELECTRICAL PLAN - FIRST FLOOR EMCS

1:1001 0 700030001000

PLAN

NORTH

GENERAL NOTES

KEYNOTES

1 MOTORIZED DAMPER. REFER TO MECHANICAL DRAWINGS

FOR EXACT LOCATION. WIRE TO AUX CONTACT ON ACU FOR

HARD-WIRE INTERLOCK.

1. ALL CONDUIT TO BE ROUTED ABOVE CEILING, AND BELOW

STRUCTURAL BEAMS. NO CORE DRILLING OF STRUCTURAL

BEAMS PERMITTED.

2. ALL EXTERIOR WIRING TO BE IN WATER TIGHT CONDUIT.

3. ALL CONNECTIONS TO INDOOR AND OUTDOOR UNITS SHALL

HAVE A MECHANICAL CONNECTOR. LOOSE WIRING FROM END

OF CONDUIT TO UNIT SHALL NOT BE PERMITTED.

4. REFRIGERATION AND ELECTRICAL RACEWAYS ON EXTERIOR

OF FACILITY SHALL HAVE WEATHER RESISTANT CALKING LINED

ON BOTH SIDES OF THE RACEWAY AND COMPLETELY AROUND

ALL JUNCTION BOXES.

EXISTING FIBER SPLICE BOX. ROUTE NEW FIBER TO NEW

EMCS PANELS IN MECHANICAL ROOM. REFER TO EM002,

AND EM504 FOR MORE INFORMATION.

02 03 04 05 06 07 08 09 11 12 13 14

B

C

D

E

F

14'10

M

ATC

H

LIN

E

T TT T T T T T T T

T TT T T T T T TT T

FROM 102

TO 302

FROM 103

TO 303

FROM 105

TO 305

FROM 107

TO 307

FROM 109

TO 309

FROM 211

TO 311

FROM 113

TO 313

FROM 119

TO 319

FROM 121

TO 321

FROM 123

TO 323

FROM 104

TO 304

FROM 106

TO 306

FROM 108

TO 308

FROM 110

TO 310

FROM 112

TO 312

FROM 114

TO 314

FROM 116

TO 316

FROM LD1

TO 318

FROM LG1

TO LG3

FROM 101

TO 301

FROM HP1

TO 318

FROM HP1

TO UNIT 322

FROM UNIT 124

TO UNIT 324

S2

STAIR 2

S1

STAIR 1

UNIT 223

UNIT 221

UNIT 224

UNIT 222

UNIT 219

UNIT 218

ST2

STORAGE 2

C2W

CORRIDOR 2W

LG2

LOUNGE 2

LD2

LAUNDRY 2216

UNIT 216

UNIT 214

UNIT 212

UNIT 210

UNIT 208

UNIT 206

UNIT 204

UNIT 202

UNIT 201

UNIT 203

UNIT 205

UNIT 207

UNIT 209

UNIT 211

UNIT 213

J2

JANITOR 2

C2

CORRIDOR 2

ZONE 2

ZONE 1 ZONE 2 ZONE 3

ZONE 5 ZONE 6 ZONE 7

D 11 D

D 11 D

D 11 D

D 11 D

D 11 D

D 11 D

D 1

D 1

1 D

1 D

D 11 D

D 1D 11 D

D 1

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

T T TT T T

T T TT T T

FROM UNIT 126

TO UNIT 326

FROM UNIT 128

TO UNIT 328

FROM UNIT 130

TO UNIT 330

FROM UNIT 132

TO UNIT 332

FROM UNIT 134

TO UNIT 334

FROM UNIT 136

TO UNIT 336

FROM 125

TO 325

FROM 127

TO 327

FROM 129

TO 329

FROM 123

TO 323

FROM 133

TO 333

FROM 135

TO 335

STAIR 3

UNIT 233UNIT 231UNIT 229UNIT 227UNIT 225

UNIT 232UNIT 230UNIT 228UNIT 226 UNIT 236UNIT 234

UNIT 235

CORRIDOR 2E

ZONE 3 ZONE 4

ZONE 7 ZONE 8

D 1 1 D

D 1 1 D

D 11 D

D 11 D

D 11 D

D 11 D

EM102

EL

EC

TR

IC

AL

P

LA

N

SE

C O

N D

F

LO

O R

E M

C S

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

SCALE:

ELECTRICAL PLAN - SECOND FLOOR EMCS

1:1001 0 700030001000

PLAN

NORTH

GENERAL NOTES

KEYNOTES

1 MOTORIZED DAMPER. REFER TO MECHANICAL DRAWINGS

FOR EXACT LOCATION. WIRE TO AUX CONTACT ON ACU FOR

HARD-WIRE INTERLOCK.

1. ALL CONDUIT TO BE ROUTED ABOVE CEILING, AND BELOW

STRUCTURAL BEAMS. NO CORE DRILLING OF STRUCTURAL BEAMS

PERMITTED.

02 03 04 05 06 07 08 09 11 12 13 14

B

C

D

E

F

14'10

M

ATC

H

LIN

E

T TT T T T T T T T

T TT T T T T T TT T

FROM 202

TO 402

FROM 204

TO 404

FROM 202

TO 402

FROM 208

TO 408

FROM 210

TO 410

FROM 212

TO 412

FROM 214

TO 414

FROM 216

TO 416

FROM 218

TO 418

FROM 222

TO 422

FROM 224

TO 424FROM LD2

TO LD4

FROM 201

TO 401

FROM 203

TO 403

FROM 205

TO 405

FROM 207

TO 407

FROM 211

TO 411

FROM 213

TO 413

FROM 219

TO 419

FROM 221

TO 421

FROM 223

TO 423

FROM 209

TO 409

S2

STAIR 2

S1

STAIR 1

UNIT 318

UNIT 319

UNIT 321

UNIT 323

UNIT 324

UNIT 322

LG3

LOUNGE 3

ST3

STORAGE 3

C3W

CORRIDOR 3W

LD3

LAUNDRY 3316

UNIT 316

UNIT 314

UNIT 312

UNIT 310

UNIT 308

UNIT 306

UNIT 304

UNIT 302

UNIT 301

UNIT 303

UNIT 305

UNIT 307

UNIT 309

UNIT 311

UNIT 313

J3

JANITOR 3

C3

CORRIDOR 3

FROM LG1

TO LG3

ZONE 1 ZONE 2 ZONE 3

ZONE 5 ZONE 6 ZONE 7

1 D

1 D

D 1

D 1

1 D

1 D

D 1

D 1

1 D

1 D

D 1

D 1

D

D 1

D 1

1 D

1 D

D 1

D 1D 1

1 D

D 1

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

T T TT T T

T T TT T T

FROM 226

TO 426

FROM 228

TO 428

FROM 230

TO 430

FROM 232

TO 432

FROM 234

TO 434

FROM 236

TO 436

FROM 225

TO 425

FROM 225

TO 427

FROM 229

TO 429

FROM 231

TO 431

FROM 233

TO 433

FROM 235

TO 435

S3

STAIR 3

UNIT 333

UNIT 332

UNIT 330

UNIT 331

UNIT 325

UNIT 327

UNIT 329

UNIT 328

UNIT 326

UNIT 334

UNIT 335

UNIT 336

C3E

CORRIDOR 3E

ZONE 7 ZONE 8

D 1 1 D

D 1 1 D

D 11 D

D 11 D

D 11 D

D 11 D

EM103

EL

EC

TR

IC

AL

P

LA

N

TH

IR

D

F

LO

O R

E M

C S

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

SCALE:

ELECTRICAL PLAN - THIRD FLOOR EMCS

1:1001 0 700030001000

PLAN

NORTH

GENERAL NOTES

KEYNOTES

1 MOTORIZED DAMPER. REFER TO MECHANICAL DRAWINGS

FOR EXACT LOCATION. WIRE TO AUX CONTACT ON ACU FOR

HARD-WIRE INTERLOCK.

1. ALL CONDUIT TO BE ROUTED ABOVE CEILING, AND BELOW

STRUCTURAL BEAMS. NO CORE DRILLING OF STRUCTURAL BEAMS

02 03 04 05 06 07 08 09 11 12 13 14

B

C

D

E

F

14'10

M

ATC

H

LIN

E

T TT T T T T T T T

T TT T T T T T TT T

S2

STAIR 2

S1

STAIR 1

LG4

DAY ROOM 4

UNIT 418

UNIT 419

UNIT 423

ST4

STORAGE 4

UNIT 422

UNIT 424

UNIT 416

UNIT 414

UNIT 412

UNIT 410

UNIT 408

UNIT 406

UNIT 404

UNIT 402

UNIT 401

UNIT 403

UNIT 405

UNIT 407

UNIT 409

UNIT 411

UNIT 413

LD4

LAUNDRY 4

J4

JANITOR 4

UNIT 421

C4

CORRIDOR 4

C4W

CORRIDOR 4W

RR4

RRM 4

FROM 302 FROM 304 FROM 306 FROM 308 FROM 310 FROM 312

FROM 314 FROM 316 FROM 318 FROM 322 FROM 324FROM LD3

FROM 201

TO 401

FROM 203

TO 403

FROM 205

TO 405

FROM 207

TO 407

FROM 211

TO 411

FROM 213

TO 413

FROM 219

TO 419

FROM 221

TO 421

FROM 223

TO 423

FROM 209

TO 409

FROM LG1

TO LG3

ZONE 1 ZONE 2 ZONE 3

ZONE 5 ZONE 6 ZONE 7

1 D

1 D

D 1

D 1

1 D

1 D

D 1

D 1

1 D

1 D

D 1

D 1 1 D

D 1

D 1

1 D

1 D

D 1

D 1

1 D

D 1

D 1

A

14 15 16 17 18 19 20

B

C

D

E

F

14'

M

ATC

H

LIN

E

T T TT T T

T T TT T T

S3

STAIR 3

UNIT 425

UNIT 434

UNIT 426

UNIT 428

UNIT 430

UNIT 432

UNIT 427

UNIT 429

UNIT 431

UNIT 433

UNIT 435

C4E

CORRIDOR 4E

UNIT 436

FROM 326 FROM 328 FROM 330 FROM 332 FROM 334 FROM 336

FROM 325 FROM 327 FROM 329 FROM 331 FROM 333 FROM 335

ZONE 3 ZONE 4

ZONE 7 ZONE 8

D 1 1 D

D 1 1 D

D 11 D

D 11 D

D 11 D

D 11 D

EM104

EL

EC

TR

IC

AL

P

LA

N

FO

U R

TH

F

LO

O

R E

M C

S

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

SCALE:

ELECTRICAL PLAN - FOURTH FLOOR EMCS

1:1001 0 700030001000

PLAN

NORTH

GENERAL NOTES

KEYNOTES

1 MOTORIZED DAMPER. REFER TO MECHANICAL DRAWINGS

FOR EXACT LOCATION. WIRE TO AUX CONTACT ON ACU FOR

HARD-WIRE INTERLOCK.

1. ALL CONDUIT TO BE ROUTED ABOVE CEILING, AND BELOW

STRUCTURAL BEAMS. NO CORE DRILLING OF STRUCTURAL BEAMS

FLOOR 1

FLOOR 2

TO WALL

12400

01 02 03 04 05 06 07 08 09 11 12 13 14

FLOOR 3

FLOOR 4

14'

GL

-500

M

ATC

H

LIN

E

FLOOR 1

FLOOR 2

TO WALL

12400

14 15 16 17 18 19 20

FLOOR 3

FLOOR 4

14'

GL

-500

EMCS HANDHOLE

(TYP)

EMCS PULLBOXGRADE

SCALE:

EMCS EXTERIOR ELEVATION - SOUTH

1:1001 0 700030001000

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

EM201

EM

C

S

EX

TE

R

IO

R

E

LE

VA

TI

O N

SO

U

TH

K.

H

EL

BI

G

KR

H

AT

W

SCALE:

EMCS EXTERIOR ELEVATION - SOUTH

1:1002 0 700030001000

SCALE:

EMCS TYPICAL UNDERGROUND DISTRIBUTION

1:1003 0 700030001000

FLOOR 1

FLOOR 2

TO WALL

12400

01020304050607080911121314

FLOOR 3

FLOOR 4

14'

GL

-500

M

ATC

H

LIN

E

FLOOR 1

FLOOR 2

TO WALL

12400

01020304050607080911121314

FLOOR 3

FLOOR 4

14'

GL

-500

M

ATC

H

LIN

E

FLOOR 1

FLOOR 2

TO WALL

12400

14151617181920

FLOOR 3

FLOOR 4

14'

GL

-500

M

ATC

H

LIN

E

SCALE:

EMCS EXTERIOR ELEVATION - NORTH

1:1001 0 700030001000

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

EM202

EM

C

S

EX

TE

R

IO

R

E

LE

VA

TI

O N

N

O R

TH

K.

H

EL

BI

G

KR

H

AT

W

EM501

PO

IN

TS

L

IS

T

SCALE:

POINTS LIST

NONE1

SCALE:

ELECTRIC METER POINTS LIST

NONE2

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

GENERAL NOTES:

1. PROVIDE PATCH CABLE BETWEEN SWITCHES AND

PATCH PANELS AS REQUIRED.

2. HVAC CONTROL SYSTEM (EMCS) SHALL BE THE

PROPERTY OF THE USAF AT THE END OF THE PROJECT,

IN ITS ENTIRETY. THIS SHALL INCLUDE (BUT NOT

LIMITED TO) ALL PROGRAMMING AND SOFTWARE

LICENSES. CONTROLS CONTRACTOR SHALL PROVIDE

THE GOVERNMENT FULL AND UNRESTRICTED ACCESS

TO ALL ASPECTS OF THE EMCS HEAD-END AND

BACK-END. THERE SHALL NOT BE ANY ASPECT OF

EMCS THAT IS INACCESSIBLE TO THE GOVERNMENT.

3. CONTRACTOR SHALL PROVIDE ALL LABOR, TOOLS,

EQUIPMENT TO COORDINATE EXISTING FRONT END

FOR EMCS (B794). CONTRACTOR MUST COORDINATE IP

ADDRESS, GRAPHICS, POP UP ALARMS WITH USAF TO

ENSURE COMPLETE FUNCTIONALITY.

4. CONTRACTOR TO ASSUME ALL POINTS ARE

REPRESENTED GRAPHICALLY. THIS INCLUDES

ELECTRICAL (POWER), METERS, AND MECHANICAL

SYSTEMS.

5. CONTRACTOR TO PROVIDE DOCUMENTATION AND

ANALYSIS OF THE MECHANICAL SYSTEMS OPERATE AS

DESIGNED. CONTRACTOR IS RESPONSIBLE TO NOTIFY

THE BASE IMMEDIATELY IN WRITING IF DESIGNED

SYSTEMS DO NOT MEET MANUFACTURES OR

SPECIFICATION REQUIREMENTS.

SCALE:

DWH POINTS LIST

NONE1

B SA -VGV

EW-50J

ECLIPSE

CONTROLLER

W

3 33 3

1 1 11

4 4

5 555

M1 M2 MS

M1 M2MS

TB3

TB5

A B

M1 M2 MS

M1 M2MS

TB

TBTB

EM502

EM

C

S D

ET

AI

LS

SCALE:

MECHANICAL EQUIPMENT WIRING DIAGRAM

NONE1

SYMBOL LEGEND:

TIA-485 MODBUS CABLE

WATER METER CABLE. TWISTED PAIR CABLE.

VERIFY CABLE WITH WATER METER VENDOR AND

EC-BOS/IO-16 VENDOR

SCALE:

TYPICAL OUTDOOR UNIT

NONE2 SCALE:

TYPICAL INDOOR UNIT

NONE3

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

KEYNOTES

1 COMMUNICATION CABLE. PROVIDE COMMUNICATION

WIRING BETWEEN EMCS, OUTDOOR HEAT PUMPS AND

INDOOR UNITS. 1PR SHIELDED 1.25mm² (#16 AWG) IN

SEPARATE CONDUIT FROM POWER. VERIFY CABLE WITH

MANUFACTURERS REQUIREMENTS.

OUTDOOR UNIT

INDOOR UNIT

THERMOSTAT CABLE

THERMOSTAT (SEE MECHANICAL SPECIFICATIONS)

ELECTRIC METER OMRON KM-N2-FLK

WATER METER

SYSTEM CONTROLLER EW-50J TYPICAL OF 4

EMCS PANEL

TIA-485 MODBUS CABLE

(1) TIA-45-485 MODBUS CABLE TO WATER METER

OUTDOOR AIR MOTORIZED DAMPER

12DRAFT

PANEL 1 PANEL 2 PANEL 3

ZONE 1

ZONE 2

ZONE 3

ZONE 4 ZONE 8

ZONE 7

ZONE 6

ZONE 5

6 (TYP)

(TYP)

77 87 8

14 1414

21 21

PANEL FRONT (TYP)

(TYP)

(TYP)

EM503

EM

C

S D

ET

AI

LS

SCALE:

TYPICAL EMCS CABINET

NONE1

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

KEYNOTES

1 NEW EMCS ENCLOSURE. PROVIDE IP 44 STAINLESS STEEL

CABINET 700mm WIDE X 1,200mm HIGH X 250mm DEEP MINIMUM

WITH WOOD BACK BOARD. (PANASONIC BPS711220V WITH

LOCK AND KEY. LOCK TYPE SHALL BE TAKIGEN TAK70).

PROVIDE ON INSIDE DOOR OF CABINET. PROVIDE LAMINATED

LINE DIAGRAM OF INTERIOR WIRING AND CONDUITS OF

CABINET. PAINT ENCLOSURE TO MATCH BASE CUSTOM

STANDARD COLOR.

PROVIDE MEDIA CONVERTER WITH POWER SUPPLY. PROVIDE

CATEGORY 5E CABLE BETWEEN MEDIA CONVERTER AND 12

PORT ETHERNET SWITCH.

PROVIDE 12 STRAND SINGLE MODE FIBER OPTIC PATCH CABLE

BETWEEN FIBER PATCH PANEL LOCATED IN 1ST FLOOR OFFICE

OF DORM 542 AND MEDIA CONVERTER. TERMINATE (2)

STRANDS ONTO MEDIA CONVERTER.

CENTRAL CONTROLLER (MITSUBISHI EW-50E). PROVIDE WITH

INDIVIDUAL POWER SUPPLY AND BREAKER.

65mm SQUARE PVC WIREWAY MINIMUM.

PROVIDE M-NET CABLE BETWEEN EW-50E AND TERMINAL

STRIP. TYPICAL ALL.

STAINLESS STEEL STRUT CONDUIT SUPPORT

LISTED RIGID STEEL CONDUIT TO HEATPUMPS,

NEW 24 SPACE TERMINAL STRIP. NUMBER ALL SPACES 1-24.

LABEL ALL WIRING ENTERING ENCLOSURE WITH REVERSE

NUMBERING METHOD. PROVIDE TERMINAL WIRE JACKET.

DEDICATED 120V, 20A CIRCUIT FROM NEW PANEL "A".

PROVIDE TWO 125V, 20A NEMA5-20R, WEATHER RESISTANT,

GFCI RECEPTACLE, SURFACE MOUNTED INSIDE ENCLOSURE.

CIRCUIT TO PANEL "A" REFER TO ELECTRICAL DRAWINGS FOR

MORE INFORMATION.

PROVIDE (2) 3.5mm² & (1) 3.5mm² GROUND IN 28MM RIGID STEEL

CONDUIT.

NEW GROUND BUS BONDED TO ENCLOSURE AND ELECTRICAL

PANEL "A". MUST BE 10 OHMS OR LESS.

DRAIN AND PRESSURE RELIEF - STAINLESS STEEL (HOFFMANN

H20MIT OR EQUAL).

ECLIPSE CONTROLLER WITH ECY-16DI AND ECY PC-24 POWER

SUPPLY AND INDIVIDUAL CIRCUIT BREAKER.

CATEGORY 5E PATCH CABLE/WEATHERPROOF RJ45.

WATER METER CABLE

ELECTRIC METER CABLE. OMRON KM-N2FLKUL

EC-BOS 8, PROVIDE INDIVIDUAL CIRCUIT BREAKER.

UNINTERRUPTIBLE POWER SUPPLY (UPS) WITH SURGE

PROTECTION AND 2 HOUR STANDBY POWER.

SURGE PROTECTIVE DEVICE FOR POWER SUPPLY

PROVIDE HVAC SYSTEM COMM CABLE 1RP SHIELDED 2.1MM IN

28MM CONDUIT BETWEEN CONTROLLER HEAT PUMP AND

ACU'S. REFER TO EM002 FOR QUANTITIES. REFER TO

EM101-EM104 FOR LOCATIONS.

A-464-L1-1 HANDLE AND LOCK FOR EMCS PANEL BOARD.

MATERIAL: A-464-L1/ALUMINUM ALLOY (ADC)

FINISH: A-464-L1-SATELLITE CHROME PLATE (MACr) (MZCr)

KEY NUMBER: TAK70 NO. 7070 COORDINATE WITH 35CES

PROVIDE (2) FANS ON EXTERIOR OF EMCS PANELS. PROVIDE

WITH DROUGHT HOLE AND FAN FILTER.

PROVIDE BACNET CABLE BETWEEN NETWORK SWITCH AND

EW-50E. TYPICAL.

24DRAFT

UPS ETHERNET SWITCH

MEDIA CONVERTER

EC-BOS

EM504

EM

C

S D

ET

AI

LS

SCALE:

SPLICE BOX

NONE1

K.

H

EL

BI

G

KR

H

AT

W

R E

P A

R

M

B

M I S

A W

A

A

S

E

J A

P A

N

(Q

KK

A1

2)

FA

-1

8- F-

JU

N

E

, 2

SHEET

IDENTIFICATION

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

C

KD

B

Y:

SO

LI

C

IT

AT

IO

N

N O

D

AT

E:

C O

N

TR

AC

T

N O

SU

BM

IT

TE

D

B Y:

U .S

. A

IR

F O

R C

E C

IV

IL

E N

G

IN

EE

R

C

EN

TE

R

O

TI

E R

S& H

J O

IN

T

VE

N

TU

R

E

N

. M

AY

FA

IR

R O

AD

S

U

IT

E

M

IL

W

AU

KE

E, W

I 5

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N D

A T

E

FINAL DESIGN

SIGNED

THIS WORK WAS PREPARED

BY ME OR UNDER MY

SUPERVISION

SHEET OF 232

PA

U

L

VA

N D

EN

BE

R G

GENERAL NOTES:

1. EXISTING FIBER PATCH PANEL LOCATED IN DORM 542

OFFICE. PANEL IS EXISTING TO REMAIN, SHOWN AS

REFERENCE ONLY.

SCALE:

UPS WIRING DIAGRAM

NONE2

EM001-EM001
EM001-EM001
EM002-EM003 (2)
EM002-EM003 (2)
EM003-EM002
EM003-EM002
EM101. 102, 103, 104-EM101
EM101. 102, 103, 104-EM101
EM101. 102, 103, 104-EM102
EM101. 102, 103, 104-EM102
EM101. 102, 103, 104-EM103
EM101. 102, 103, 104-EM103
EM101. 102, 103, 104-EM104
EM101. 102, 103, 104-EM104
EM201-M-201
EM201-M-201
EM202-M-202
EM202-M-202
EM501-em501
EM501-em501
EM502-EM502
EM502-EM502
EM503-EM503
EM503-EM503
EM503-EM504
EM503-EM504

File details come from the government source that posted it. Updated .