Approved_FDOT_Utility_Permit_Package.pdf
PDF 8 MB Posted
- Attached to
- East Palatka Septic to Sewer Project - Phase IV
- Solicitation number
- Bid 25-14
- Issued by
- Polk County, Florida
About this file
This document is a Florida Department of Transportation (FDOT) Utility Permit for the Putnam County Utility Department's Septic to Sewer Phase IV Project in East Palatka, Florida. The permit authorizes the construction of approximately 3,115 linear feet of 6-inch PVC (DR-18) force main with air relief valves, connecting into an existing 6-inch force main from the Paradise Point Pump Station at the southwest intersection of Horse Landing Road and US 17. The project will involve directional boring and installation of force main along Highway 17, with work anticipated to start on 1/27/2025 and expected to be completed within 20 calendar days.
The utility permit includes specific requirements for erosion control, traffic management, and site restoration. The project is part of a larger infrastructure improvement initiative to convert septic systems to a centralized sewer system in the Dunns Creek area. The permit mandates compliance with FDOT specifications, including proper backfilling, sod restoration, and maintenance of traffic control. Additional specifications cover environmental protections such as silt fencing, sediment control, and requirements for preserving existing vegetation. The work will be conducted within FDOT right-of-way and must adhere to strict guidelines for utility installation, including notifications to various utility owners and careful management of existing infrastructure.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Rule 14-46.001 F.A.C.
FLORIDA DEPARTMENT OF TRANSPORTATION December 14, 2016
UTILITY PERMIT
PERMIT NO:__________________________________
STATE ROAD INFORMATION
County: Section: State Road No: Beginning Mile Post: Ending Mile Post:
APPLICANT INFORMATION
The Utility Agency Owner (UAO) shall be identified in this Applicant Information Box. When the UAO is a City or County and desires to have the Utility Builder make a joint permit applicant, as prescribed in Section 2.1(4) of the 2017 Utility Accommodation Manual (UAM), the Utility Builder shall also be identified in this Applicant Information Box. A Utility Builder alone cannot apply for a utility permit without the City or County adding them as a joint applicant.
Utility Agency/Owner (UAO) Utility Builder (only applicable when the UAO is a City or County) Name: _____________________________________ Name: ______________________________________
Contact Person: _____________________________________ Contact Person: ______________________________________ Address: _____________________________________ Address: ______________________________________
City: _____________________________________ City: ______________________________________ State: _____ State: _____ Zip: _________ Zip: _________
Telephone: _____________________________________ Telephone: ______________________________________ Email: ____________________________________ Email: ______________________________________
WORK DESCRIPTION
The Applicant(s) requests permission from the Florida Department of Transportation (FDOT) to construct, operate, and maintain the utilities as described below and as depicted in the incorporated documentation.
Utility Work No: ___________________________
Additional sheets are attached and are incorporated into this permit Yes No For FDEP certification, the FDOT agency report is attached in accordance with UAM Section 2.4.1 (13) Yes No
TRAFFIC CONTROL (TCP)
The TCP will comply with the following 600 series index(es) ________________________________________________________________________ A TCP has been attached and incorporated into this permit application in compliance with UAM Section 2.4.2.
MOT Technician’s contact information (may be supplied at the two (2) business day notification to FDOT):
Name: ________________________________ Telephone ________________________ Email: _______________________________
COMMENCEMENT OF WORK
The UAO and/or Utility Builder shall commence actual construction in good faith within sixty (60) calendar days after approval of the permit application. If the beginning date is more than sixty (60) calendar days from the date of approval, the UAO and/or Utility Builder must review the permit with the FDOT Approving Engineer listed to make sure no changes have occurred to the transportation facility that would affect the permit’s continued approval. The UAO and/or Utility Builder shall make good faith efforts to expedite the work and complete the work within the calendar days indicated.
Anticipated Start Date: ___________________ Calendar days needed to completed: ________
Putnam
(386) 329-0346 ext. ______
Florida
SR 15
Putnam County Utlity Dept
1/27/2025
20.761
P.O. Box 310
32131
Construct approximately 3,115 L.F. of 6" PVC (DR-18) force main with air relief valves and manifold into existing 6" force main from Paradise Point Pump Station at southwest intersection of Horse Landing Road and US 17.
2024-H-297-00293
76010000
Putnam County Utlity Dept
East Palatka publicworks@putnam-fl.gov
21.170
Approved 2024-H-297-00293 Christopher Pogue
12/3/2024
Florida Department of Transportation
UTILITY PERMIT
December 14, 2016
PERMIT NO:_________________________________
APPLICANT SIGNATURE
By the below signature(s) the UAO and/or Utility Builder agree(s) to construct, operate, and maintain the work as noted in the above Work Description, shown in plans and incorporated documents, in compliance with the UAM, all instructions noted in the FDOT Special Instructions Box, and special instructions incorporated into this permit. The UAO and/or Utility Builder declares, the location of all existing utilities that it owns or has an interest in, both aerial and underground, are accurately shown on the plans of the work areas. In accordance with UAM Section 2.8, the UAO and/or Utility Builder further declares that a letter of notification was delivered to the owners of other facilities within the work areas and that those listed below are the only facility owners known to be involved or potentially impacted by the proposed work.
Date Notified: Name of other facility owners (attach additional sheets if necessary).
Utility Agency/Owner Utility Builder (when applicable)
Signature: ____________________________ Date: ________________ Signature:___________________________ Date: _______________ Name (printed): _____________________________________________ Name (printed): __________________________________________ Title: ______________________________________________________ Title: ___________________________________________________
FDOT PROJECT INFORMATION
Pursuant to UAM Section 2.1(10), the utility work is within FDOT projects listed below and must have a Utility Work Schedule for each project approved prior to commencement of work within the FDOT project limits:
FDOT SPECIAL INSTRUCTIONS
In accordance with UAM Section 2.7, FDOT incorporates the below and attached special instructions into this permit.
Additional FDOT Special Instructions are attached and incorporated into this permit. Yes No
PERMIT APPROVAL
By signature below, FDOT gives permission to the UAO and /or Utility Builder to construct, operate, and maintain the utilities indicated in this Utility Permit in compliance with the UAM, all incorporated documents, and special instructions. Any changes to the approved work must be approved by the FDOT’s Approving Engineer and attached and incorporated into this permit in accordance with UAM Section 2.11.
Approving Engineer: _____________________________________________ Date: _______________ Name: _____________________________________________
Title:______________________________________________
Notification of Utility Work to be provided to: Telephone _____________________ or Email: _____________________________
An FDOT Representative is required to be present on the worksite prior to commencement of work. Yes No Rep. Name: _____________________________ Telephone _____________________ Email: _____________________________
12/3/2024
See Attachment for instructions on how to proceed prior to starting proposed work within FDOT Right of Way. If you are unable to reach the assigned, please contact the St. Augustine Maintenance, Permits Office at 904-825-5036
Note: Maintenance of Traffic Technician information not completed at the time of application submittal will be required when submitting work initiation.
11/14/2024
(386) 614-6513 ext. ______ Paul.Harvey@atkinsrealis.com
Christopher Pogue
Christopher Pogue (digital signature) paul.harvey@atkinsrealis.com
PUTNAM COUNTY UTILITY DEPT (digital signature)
City of Crescent City Natural Gas10/22/2024 Florida Power & Light10/22/2024
AT&T10/22/2024
Uniti Fiber10/22/2024
PUTNAM COUNTY UTILITY DEPT
3866146513Paul Harvey
MAINTENANCE MANAGER/PERMITS
2024-H-297-00293
FDOT construction is proposed or underway. Refer to Financial Project Id: Project
452201-1 CONST.COMPLETE 04/04/2024
This work is NOT related to an approved Utility Work Schedule.
Approved 2024-H-297-00293
Florida Department of Transportation
UTILITY PERMIT
December 14, 2016
PERMIT NO:_________________________________
CERTIFICATION
I, the undersigned UAO and/or Utility Builder, hereby CERTIFY that the utilities were constructed and inspected in compliance with the UAM all incorporated documents, and special instructions. Pursuant to UAM Section 2.11, all changes have been approved by the FDOT’s Approving Engineer and incorporated into this permit along with all other material certifications, test results, bore logs, approved plans changes, as-built plans or other required documentation.
I also CERTIFY that work began on ________________ and was completed on ________________ and that the area was left in as good or better condition than when the work began.
Utility Agency/Owner Utility Builder (when applicable)
Signature: ____________________________ Date _________________ Signature:___________________________ Date ________________ Name (printed): _____________________________________________ Name (printed): ____________________________________________ Title: ______________________________________________________ Title: ____________________________________________________
FINAL INSPECTION OF WORK
The work was inspected and found to be in non-compliance as noted below:
All issues of non-compliance listed above have been brought into compliance and/or FDOT has no outstanding issues that need to be addressed by the UAO and/or Utility Builder. However, this final inspection does not release the UAO and/or Utility Builder of their continuing responsibilities pursuant to Rule 14-46.001, the UAM, all incorporated documents, and special instructions.
FDOT Inspector: _____________________________________________ Date: _______________ Name: _____________________________________________
Title: ______________________________________________
2024-H-297-00293
Approved 2024-H-297-00293
• All work performed within the department’s right-of-way shall conform to the most current edition of the following publications:
o Standard Specifications for Road and Bridge Construction (English).
o FDOT Standards Index (English) o FDOT Plans Prep Manual o FDOT Flexible Pavement Design Manual for New Construction and
Pavement Rehabilitation
(Should a conflict arise between the details shown in the plans and the
Department of Transportation Standards the Engineer/Applicant shall immediately confer with the Department’s engineer to resolve the discrepancy.)
• All disturbed area with the department’s right-of-way will restored to original or better condition by grading and sodding the area disturbed (Bermuda in urban, Bahia in rural).
• Per the UAM clearing of trees is not authorized for installation of utilities.
• Burning of any material or debris is prohibited in FDOT right-of-way.
• All lanes must be opened for traffic during an evacuation notice of a hurricane or other catastrophic event and shall remain open for the duration of the evacuation or event.
Approved 2024-H-297-00293
Contact Palatka City Maintenance- (386) 329-0143 for work within/between/near traffic light controlled intersections/street lighting. (Possible signal interconnect.)
Contact Putnam - Contact Jerry Andrews, (386) 336-8629 work within/between/near traffic light controlled intersections. (Possible signal interconnect.)
• Provide as built plans after permit project completion.
• Any disturbed areas will be restored with sod or like material immediately.
• Any disturbed sidewalk will be restored to current standards in original or better condition within 24 hours.
• No Hay Bales for erosion or sedimentation controls are allowed in the FDOT Right of Way.
• This permit covers work within FDOT Right of Way only.
• All direction boring will be in accordance with FDOT Specification 555 latest edition.
• Complete HDD Bore Log and submit upon completion.
Lane Closure Template:
• Any lane closure request may require 2 weeks’ notice for approval and may be restricted to night work only.
Please send the information below to the assigned FDOT Inspector/Coordinator the week prior to the proposed closure for review and approval. All requests need to be submitted by Wednesday at 5:00 the week prior. Late submittals will not be approved. Any questions/concerns, please contact the St. Augustine Permits Office at 904-825-5036.
Permit Number:
County:
Road Name:
Nearest Cross Street:
What Direction:
What lane:
Start Date:
End Date:
Start Time:
End Time:
Reason for closure:
Point of Contact:
Company:
Mobile Number:
Pollution Prevention
Did You Know???
For every acre under construction, about a dump truck and a half of soil washes into the storm system and into a nearby stream/Creek unless the contractor uses proper erosion control.
Best Management Practices (BMPs) for Erosion and Sedimentation Control at Construction Sites
Did you know that uncontrolled erosion run-off from a construction site will most likely end up in a creek or lake? Eroding construction sites are a leading cause of water quality problems in Florida. Turbid run-off from construction sites enters nearby storm sewer systems that discharge directly to water bodies. This cloudy water can:
• smother vegetation and other in-stream habitats,
• prevent light penetration within the water body,
• clog gills of fish and other aquatic organisms, and
• transport toxic metals and other compounds to our surface waters.
Erosion control is easy and can be relatively inexpensive. When developing your erosion control plan remember to apply the principals of erosion and sediment control:
• Fit development to the terrain
• Install protective measures before any clearing or earth moving
• Time grading and construction to minimize soil exposure
• Retain existing vegetation wherever possible
• Vegetate and mulch denuded areas
• Divert runoff away from denuded areas
• Minimize length and steepness of slopes
• Keep runoff velocities low
• Prepare conveyances and outlets to handle increased flows
• Trap sediment on site
• Inspect and maintain control measures
A properly installed silt fence can prevent sediments from migrating off site.
The use of best management practices (BMPs) for sedimentation and erosion control for all excavations are now required. BMPs must provide equal or better protection than those currently compiled by the Florida Department of Environmental Protection.
Approved 2024-H-297-00293
Construction Entrances
• Remove vegetation, roots, and other material from entrance.
• Lay down geotextile then 6 inches of
FDOT No. 1 Coarse Aggregate on top.
• The length of entrance must be at least
50 feet.
• Maintain as needed to prevent tracking or flow of mud onto public rights-of-way.
Silt Fences
• Install within 24 hours of land disturbance.
• Bury 8 inches of fabric in trench.
• Leave no gaps (overlap or twist ends together).
• Maintain and repair until a ground cover is established.
Soil Piles
• Locate away from downslope streets, driveways, streams, wetlands, lakes, etc.
• Keep covered with plastic sheeting.
• Carefully wet down exposed soil to keep dust and erosion to a minimum.
Storm Sewer Inlet Protection
• Protect nearby storm sewer inlets with straw or synthetic bale, synthetic fabric, filter sock, or other measure.
• Inspect, repair, and replace as needed, and remove sediment deposits after every storm.
Sediment Cleanup
• Remove soil tracked onto the street after each workday.
• Cleanup all soil that has washed off site following a storm.
Preserving Existing Vegetation
• Preserve existing trees, shrubs, and other vegetation whenever possible.
• To prevent root damage, do not grade, place soil piles, or park vehicles near trees marked for preservation.
• Place plastic mesh around trees extending to the drip line to protect the area below their branches.
Revegetation
• Seed, sod, or mulch bare soil as soon as possible. Vegetation is the most effective way to control erosion.
Seeding and Mulching
• Spread and compact 2 – 4 inches topsoil.
• Seed with appropriate mix for site and season.
• Rake lightly to cover seed with ¼ inch of soil.
• Mulch with anchored straw.
• Gently water every other day until grass is 2 inches tall.
Sodding
• Leave or replace 4 inches of topsoil.
• Lightly water soil before laying sod.
• On slopes, lay sod starting at the bottom and work toward the top, laying in a brickwork pattern. Peg each piece down in several places.
• Use sod from sources certified by the Division of Plant Industry as “noxious weed-free”.
• Initial watering should wet soil 6 inches deep. Then water lightly every other day to keep soil moist.
TIPS FOR COMMONLY USED
BMPs
For more information contact:
Alan Obaigbena, P.E
Florida Department of Transportation
800-749-2967 extn 7064
For additional information regarding erosion and sediment control, refer to the “Florida Development Manual: A Guide to Sound Land and Water Management” and the FDEP “Stormwater, Erosion, and Sedimentation Control Inspector Manual”.
Approved 2024-H-297-00293
LOCATION
PROJECT
N
NO.
SHEET
1:57:06 PM I:\23jobs\23L0104\CAD\Site\Sht01_PH_IV_KEYSRD01.dgnreed02048 10/8/2024
SHEET DESCRIPTIONSHEET NO.
INDEX OF UTILITY PLANS
TO CRESCENT CITY
Dunn's Creek
Area
3 2
211924
23 1
50 45
Swamp Road
Rd.
San
Ma teo
R d.
Raceway
Chapel
FS
Lundy
IS.
BUZZARD
Landing
Browns
Pt.
Browning
Pt.
Pt.
Pt.
Harts
P
P
PERRIN
Community
T ur ne r
Riv er
Tram
Piney
MATEO
SAN
Moritani
PALATKA
Pop.10,033
RAVINEGARDENS
STATE PARK
Crane
SAN MATEO
R d.
P
P
P
Cracker
PALATKA
EAST
H el l
Ba y
Murphy
Cr
Putnam County
Dunns
Long
Conservation
Swam p
SATSUMA
EXPRESSWAY
T U
R N P
IK
E
PENSACOLA FORT WALTON
BEACH
PANAMA
CITY
CHIPLEY
TALLAHASSEE
JACKSONVILLE
ST AUGUSTINE
GAINESVILLE
OCALA DAYTONA BEACH
DELAND
NEW PORT RICHEY
TAMPA
LAKELAND
MELBOURNE -
COCOA
ORLANDO
BARTOWST PETERSBURG
SARASOTA -
BRADENTON
FT PIERCE
FT MYERS
WEST PALM
BEACH
FT LAUDERDALE
MIAMI
NAPLES
KEY WEST
CITY
LAKE
F
LO
R
ID
A 'S
BEACH LINE
EAST PALATKA
BOARD OF COUNTY COMMISSIONERS
CONTRACT PLANS
PUTNAM COUNTY - FLORIDA
PROJECT LOCATION MAP
PROJECT VICINITY MAP
PREPARED BY:
B
P
B
P.E. LICENSE NO. 61786
DARYL R. MYERS, P.E.
ENGINEER OF RECORD:
FAX No. (904) 737-0040
PHONE No. (904) 737-0090
JACKSONVILLE, FL 32216-3685
8075 GATE PARKWAY WEST, SUITE 204
HANSON PROFESSIONAL SERVICES INC
(DUNNS CREEK AREA)
SEPTIC TO SEWER PHASE IV
EAST PALATKA
DUNNS CREEK AREA
PHASE IV
PROJECT LOCATION
C-1
OCTOBER 11, 2024
SUBMITTAL
FINAL PLANS
EROSION CONTROL NOTES AND DETAILS
STANDARD DETAILS
GAIL DRIVE PUMP STATION ELECTRICAL
GAIL DRIVE PUMP STATION PLAN AND SECTION
GAIL DRIVE PUMP STATION SITE PLAN
E-ONE PUMP STATION DETAILS
FORCE MAIN PLAN AND PROFILE
LOW PRESSURE SEWER SYSTEM PLAN
KEY SHEET
GENERAL NOTES AND LEGEND
GENERAL NOTES
SIGNATURE SHEET
TITLE SHEET
C-64
C-58 THRU C-63
C-51 THRU C-57
C-50
C-49
C-47 THRU C-48
C-42 THRU C-46
C-6 THRU C-41
C-5
C-4
C-3
C-2
C-1
Approved 2024-H-297-00293 Christopher Pogue
12/3/2024
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
10/8/2024reed02048 I:\23jobs\23L0104\CAD\Site\Sht02_PH_IV_SIGNRD01.DGN1:58:02 PM
DATE DESCRIPTION
REVISIONS
BOARD OF COUNTY COMMISSIONERS
PUTNAM COUNTY
P.E. License No. 61786
Daryl R. Myers, P.E.
Engineer of Record:
Offices Nationwide
Jacksonville, Florida 32216-3685
8075 Gate Parkway West, Suite 204
Hanson Professional Services Inc.
SEPTIC TO SEWER PHASE IV
EAST PALATKA NO.
SHEET
HANSON PROFESSIONAL SERVICES INC.
8075 GATE PARKWAY WEST, SUITE 204
JACKSONVILLE, FLORIDA 32216-3685
SIGNED AND SEALED BY;
THIS DOCUMENT HAS BEEN DIGITALLY
ON THE ELECTRONIC DOCUMENTS.
THE SIGNATURE MUST BE VERIFIED
NOT CONSIDERED SIGNED AND SEALED.
PRINTED COPIES OF THIS DOCUMENT ARE
CERTIFICATE OF AUTHORIZATION 7961
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
SHEET DESCRIPTION
P
ON THE DATE ADJACENT TO THE SEAL
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
SHEET DESCRIPTION
SIGNED AND SEALED BY;
THIS DOCUMENT HAS BEEN DIGITALLY
ON THE ELECTRONIC DOCUMENTS.
THE SIGNATURE MUST BE VERIFIED
NOT CONSIDERED SIGNED AND SEALED.
PRINTED COPIES OF THIS DOCUMENT ARE
CERTIFICATE OF AUTHORIZATION 7961
P
ON THE DATE ADJACENT TO THE SEAL
8075 GATE PARKWAY WEST, SUITE 204
HANSON PROFESSIONAL SERVICES INC.
SHEET NO.
STATE OF
No 61786
R E
E
NI
G
NE LANOI
S S
E
F O
R P
ESNECI
L
A
DIROL
F
S
REYM .R LYR
A
D
SHEET NO.
DARYL R. MYERS, P.E. NO. 61786
STATE OF
No 92053
R E
E
NI
G
NE LANOI
S S
E
F O
R P
ESNECI
L
A
DIROL
F
N
OS
PMOHT NITS
U
A
JACKSONVILLE, FLORIDA 32216-3685
AUSTIN THOMPSON, P.E. NO. 92053
EROSION CONTROL NOTES AND DETAILS
STANDARD DETAILS
GAIL DRIVE PUMP STATION PLAN AND SECTION
GAIL DRIVE PUMP STATION SITE PLAN
E-ONE PUMP STATION DETAILS
FORCE MAIN PLAN AND PROFILE
LOW PRESSURE SEWER SYSTEM PLAN
KEY SHEET
GENERAL NOTES AND LEGEND
GENERAL NOTES
SIGNATURE SHEET
TITLE SHEET
C-64
C-58 - C-63
C-50
C-49
C-47 - C-48
C-42 - C-46
C-6 - C-41
C-5
C-4
C-3
C-2
C-1
C-51 - C-57
C-2
GAIL DRIVE PUMP STATION ELECTRICAL
SIGNATURE SHEET
SIGNATURE SHEET
SEPTIC TO SEWER PHASE IV
EAST PALATKA
C-2
Approved 2024-H-297-00293 Christopher Pogue
12/3/2024
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
Greg Reed Line
WITH BOX AND COVER
AIR RELEASE/ VACUUM VALVE
BORE PIT
8'X6' HDD ENTRY/EXIT
BORE PIT
8'X6' HDD ENTRY/EXIT
BORE PIT
8'X6' HDD ENTRY/EXIT
FUSIBLE PVC (DR-18) FORCE MAIN
DIRECTIONAL BORE 27 L.F. OF 6"
(DR-18) FORCE MAIN
120 L.F. OF 6" PVC
FUSIBLE PVC (DR-18) FORCE MAIN
DIRECTIONAL BORE 96 L.F. OF 6"
(DR-18) FORCE MAIN
351 L.F. OF 6" PVC
8'-4"
8'-8"
7'-5"
A V
E N
U E
P I N
E W
A Y
D R
IV
E
G A
IL
SILT FENCE
L F
C
P P
L F
C
P P
69 L F±
18"R
CP
INV=10.66'
UEW
INV=5.55'
UEW
MULTI USE TRAIL
ASPHALT
WOOD
12"
CONC
36"
PAVING
ASPHALT
P A
V
IN
G
A S P
H A
L T
TOB
TOE
TOB
TOB
TOE
TOB
N.M.V.
S T O P
N.M.V.
O N E W
A Y
S T R E E T
S T O P/
S T O P
W.LY INV=5.34'
E.LY INV=5.22'
SEW
S.LY INV=6.13'
N.LY INV=6.17'
MES
U
UU GAS
GAS
CONTROL POINT
HORIZONTAL/VERTICAL
ELV=12.345'
E. 461182.972'
N. 1909090.7750'
STAMPED "TRAV PT LB 3624"
FOUND IRON ROD AND CAP
HV2
11/19/2024reed02048 I:\23jobs\23L0104\CAD\Site\Sht42_PH_IV_Plan_Profile_Sheet_40_Scale.dgn2:57:22 PM
P.E. License No. 61786
Daryl R. Myers, P.E.
Engineer of Record:
Offices Nationwide
Jacksonville, Florida 32216-3685
8075 Gate Parkway West, Suite 204
Hanson Professional Services Inc.
T H
E
O F
F I
C I
A L
R
C O
D
T
I
S
E E
T
E C
T R
O N
C
G I
T A
L
Y
G N
N
A L
U
D
L E
G
A
C
SEPTIC TO SEWER PHASE IV
EAST PALATKA NO.
SHEET
-2
-2
1" = 40' Horizontal
1" = 4' Vertical
N
HWY 17
M A
T C
H
L I N
E
S E
E
S
H E
E T
LOW PRESSURE SEWER SYSTEM PLAN
-2
S E
E
S
H E
E T
M A
T C
H
L I N
E
T
Y P
FORCE MAIN
6" FUSIBLE PVC (DR-18)
T
Y P
6" PVC (DR-18) FORCE MAIN
GRADE
EXISTING
6" PVC (DR-18) FORCE MAIN
30" CPP
EXISTING
BORE PIT
8'X6' HDD ENTRY/EXIT
BORE PIT
8'X6' HDD ENTRY/EXIT
GRADE
EXISTING
6" PVC (DR-18) FORCE MAIN
FORCE MAIN
6" FUSIBLE PVC (DR-18)
WITH BOX AND COVER
AIR RELEASE/ VACUUM VALVE
BORE PIT
8'X6' HDD ENTRY/EXIT
FUSIBLE PVC (DR-18) FORCE MAIN
DIRECTIONAL BORE 96 L.F. OF 6"
(APPROX. LOCATION)
FIBER OPTIC CABLE
(APPROX. LOCATION)
FIBER OPTIC CABLE
C-42
M A
T C
H
L I N
E
S E
E
S
H E
E T
10 40
Feet
11/19/24 and Exist Pits/ARV Locations.
FDOT RAI#1 - Added Silt Fence at Bore Entry
Approved 2024-H-297-00293
WITH BOX AND COVER
AIR RELEASE/ VACUUM VALVE
BORE PIT
8'X6' HDD ENTRY/EXIT
(DR-18) FORCE MAIN
360 L.F. OF 6" PVC
FUSIBLE PVC (DR-18) FORCE MAIN
DIRECTIONAL BORE 228 L.F. OF 6"
8'-9"
7'-0
A V
E N
U E
P I N
E W
A Y
A V
E N
U E
P I N
E W
A Y
SILT FENCE
69 L F±
18"R
CP 58 LF±
18"RCP
85 LF±
18"RCP
L F
R
C P
INV=5.43'
UEW
INV=5.46'
UEW
MULTI USE TRAIL
ASPHALT
P A
V
IN
G
A S P
H A
L T
CONC
36"
PAVING
ASPHALT
NW.ly INV=9.76'
SW.ly THROAT ELV=7.90'
NE.ly THROAT ELV=7.96'
TOP ELV=8.53'
CB
SE.ly INV=2.78'
SW.ly THROAT ELV=10.76'
NE.ly THROAT ELV=10.65'
TOP ELV=11.47'
CB
INV=9.55'
MES
INV=8.40'
MES
INV=5.93'
UEW
P A
V
IN
G
A S P
H A
L T
PAVING
ASPHALT
TOB
TOE
TOB
TOB
TOE
TOB
TOB
TOE
TOB
TOB
TOB
TOES
T O P
N.M.V.
C O
N C
"C
O N C B
A S E
M E T A L W
"C
O N C B
A S E
M E T A L W
UU
UU
11/19/2024reed02048 I:\23jobs\23L0104\CAD\Site\Sht43_PH_IV_Plan_Profile_Sheet_40_Scale.dgn2:57:24 PM
P.E. License No. 61786
Daryl R. Myers, P.E.
Engineer of Record:
Offices Nationwide
Jacksonville, Florida 32216-3685
8075 Gate Parkway West, Suite 204
Hanson Professional Services Inc.
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
C
SEPTIC TO SEWER PHASE IV
EAST PALATKA NO.
SHEET
1" = 40' Horizontal
1" = 4' Vertical
N
HWY 17
M A
T C
H
L I N
E
S E
E
S
H E
E T
M A
T C
H
L I N
E
S E
E
S
H E
E T
FORCE MAIN PLAN AND PROFILE
-2
-2
S E
E
S
H E
E T
M A
T C
H
L I N
E
S E
E
S
H E
E T
M A
T C
H
L I N
E
T
Y P
6" PVC (DR-18) FORCE MAIN
FORCE MAIN
6" FUSIBLE PVC (DR-18)
6" PVC (DR-18) FORCE MAIN
GRADE
EXISTING
BORE PIT
8'X6' HDD ENTRY/EXIT
WITH BOX AND COVER
AIR RELEASE/ VACUUM VALVE
OPTIC PULL BOX
EXISTING FIBER
(APPROX. LOCATION)
EXISTING FIBER OPTIC CABLE
C-43
10 40
Feet
11/19/24 and Exist Pits/ARV Locations.
FDOT RAI#1 - Added Silt Fence at Bore Entry
Approved 2024-H-297-00293
(DR-18) FORCE MAIN
588 L.F. OF 6" PVC
5'-8" 6'-5"
SILT FENCE
CONC
36"
CONC
36"
TOE
TOE
TOB
TOB
TOB
TOB
ELV=11.126'
E. 461936.320'
N. 1909750.570'
STAMPED "LB 3624"
FOUND IRON ROD AND CAP
HV3
11/19/2024reed02048 I:\23jobs\23L0104\CAD\Site\Sht44_PH_IV_Plan_Profile_Sheet_40_Scale.dgn2:57:26 PM
P.E. License No. 61786
Daryl R. Myers, P.E.
Engineer of Record:
Offices Nationwide
Jacksonville, Florida 32216-3685
8075 Gate Parkway West, Suite 204
Hanson Professional Services Inc.
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
C
SEPTIC TO SEWER PHASE IV
EAST PALATKA NO.
SHEET
1" = 40' Horizontal
1" = 4' Vertical
N
HWY 17
M A
T C
H
L I N
E
S E
E
S
H E
E T
M A
T C
H
L I N
E
S E
E
S
H E
E T
FORCE MAIN PLAN AND PROFILE
-2
S E
E
S
H E
E T
M A
T C
H
L I N
E
S E
E
S
H E
E T
M A
T C
H
L I N
E
-2
T
Y P
6" PVC (DR-18) FORCE MAIN
6" PVC (DR-18) FORCE MAIN
GRADE
EXISTING
C-44
10 40
Feet
11/19/24 and Exist Pits/ARV Locations.
FDOT RAI#1 - Added Silt Fence at Bore Entry
Approved 2024-H-297-00293
588 L.F. OF 6" PVC
4'-3"
SILT FENCE
MULTI USE TRAIL
ASPHALT
CONC
36"
CONC
36"
UU
UU
11/19/2024reed02048 I:\23jobs\23L0104\CAD\Site\Sht45_PH_IV_Plan_Profile_Sheet_40_Scale.dgn2:57:29 PM
P.E. License No. 61786
Daryl R. Myers, P.E.
Engineer of Record:
Offices Nationwide
Jacksonville, Florida 32216-3685
8075 Gate Parkway West, Suite 204
Hanson Professional Services Inc.
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
C
SEPTIC TO SEWER PHASE IV
EAST PALATKA NO.
SHEET
1" = 40' Horizontal
1" = 4' Vertical
N
HWY 17
M A
T C
H
L I N
E
S E
E
S
H E
E T
M A
T C
H
L I N
E
S E
E
S
H E
E T
FORCE MAIN PLAN AND PROFILE
-2
-2
S E
E
S
H E
E T
M A
T C
H
L I N
E
S E
E
S
H E
E T
M A
T C
H
L I N
E
T
Y P
6" PVC (DR-18) FORCE MAIN
GRADE
EXISTING
OPTIC PULL BOX
EXISTING FIBER
(APPROX. LOCATION)
EXISTING FIBER OPTIC CABLE
C-45
10 40
Feet
11/19/24 and Exist Pits/ARV Locations.
FDOT RAI#1 - Added Silt Fence at Bore Entry
Approved 2024-H-297-00293
18 L.F. OF 6" PVC
FORCE MAIN
EXISTING 6" FORCE MAIN WITH 6" M.J.
REMOVE EXISTING 6" PLUG AND CONNECT TO
(DR-18) FORCE MAIN
127 L.F. OF 6" PVC
WITH BOX AND COVER
AIR RELEASE/ VACUUM VALVE
BORE PIT
8'X6' HDD ENTRY/EXIT
FUSIBLE PVC (DR-18) FORCE MAIN
DIRECTIONAL BORE 99 L.F. OF 6"
(DR-18) FORCE MAIN
290 L.F. OF 6" PVC
3'-8"
3'-4"
3'-3"
FORCE MAIN
EXISTING 6" SANITARY
R O
A D
H O
R S
E
L
A N
D I N
G
SILT FENCE SILT FENCE
22'18'BORE PIT
8'X6' HDD ENTRY/EXIT
FDOT INDEX 102-660
PEDESTRIAN DIVERSION
FDOT INDEX 102-660
PEDESTRIAN DIVERSION
60 LF±
18"RCP
MULTI USE TRAIL
ASPHALT
MULTI USE TRAIL
ASPHALT
P A
V
IN
G
A S P
H A
L T
P A
V
IN
G
A S P
H A
L T
WOOD
12"
CONC
36"
WOOD
14"
W O
O D
PAVING
ASPHALT
NE.ly INV=9.76'
SW.ly THROAT ELV=12.66'
NE.ly THROAT ELV=12.65'
TOP ELV=13.26'
CB
INV=10.83'
MES
INV=10.78'
MES
TOB
TOB
TOB
TOB
TOE
TOE
TOB
TOE
TOB
TOB
TOB
TOE
LIMIT
SPEED
N.M.V.
N.M.V.
W A Y
O N E
X-ING
TRAIL
LIMIT
SPEED
A
LU
M
UU
BACK FLOW
BACK FLOW
U
UU WATER
SAN
SAN
WATER
WATER
WATER
WATER
S A
N S
A N
ELV=15.384'
E. 462665.056'
N. 1910443.490'
STAMPED "LB 3624"
FOUND IRON ROD AND CAP
HV4
11/19/2024reed02048 I:\23jobs\23L0104\CAD\Site\Sht46_PH_IV_Plan_Profile_Sheet_40_Scale.dgn2:57:33 PM
P.E. License No. 61786
Daryl R. Myers, P.E.
Engineer of Record:
Offices Nationwide
Jacksonville, Florida 32216-3685
8075 Gate Parkway West, Suite 204
Hanson Professional Services Inc.
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
C
SEPTIC TO SEWER PHASE IV
EAST PALATKA NO.
SHEET
1" = 40' Horizontal
1" = 4' Vertical
N
HWY 17
M A
T C
H
L I N
E
S E
E
S
H E
E T
FORCE MAIN PLAN AND PROFILE
-2
-2
S E
E
S
H E
E T
M A
T C
H
L I N
E
T
Y P
T
Y P
6" PVC (DR-18) FORCE MAIN
MAIN
EXISTING 6" FORCE MAIN WITH 6" M.J.
REMOVE EXISTING 6" PLUG AND CONNECT TO
BORE PIT
8'X6' HDD ENTRY/EXIT
WITH BOX AND COVER
AIR RELEASE/ VACUUM VALVE
6" FUSIBLE PVC (DR-18) FORCE MAIN
BORE PIT
8'X6' HDD ENTRY/EXIT
FORCE MAIN
EXISTING 6" SANITARY
6" PVC (DR-18) FORCE MAIN
GRADE
EXISTING
(APPROX. LOCATION)
OPTIC CABLE
EXISTING FIBER
BORE PIT
8'X6' HDD ENTRY/EXIT
(APPROX. LOCATION)
EXISTING FIBER OPTIC CABLE
C-46
10 40
Feet
11/19/24
Diversions.
and Exist Pits/ARV Locations and Pedestrian FDOT RAI#1 - Added Silt Fence at Bore Entry
Approved 2024-H-297-00293
11/19/2024reed02048 I:\23jobs\23L0104\CAD\Site\Sht59_STDDETAILS03.dgn2:57:38 PM
P.E. License No. 61786
Daryl R. Myers, P.E.
Engineer of Record:
Offices Nationwide
Jacksonville, Florida 32216-3685
8075 Gate Parkway West, Suite 204
Hanson Professional Services Inc.
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
C
SEPTIC TO SEWER PHASE IV
EAST PALATKA NO.
SHEET
STANDARD DETAILS
STONE (1 CUBIC FOOT)
COMPACTED FDOT #57
FINISH GRADE OR PAVEMENT
FDOT #57 STONE (6" DEEP)
VALVE
PIPE
OPERATING NUT
A S
S
P E
C I F I E
D
461-S SIGMA 562-S OR APPROVED EQUAL
H-20 LOAD RATED VALVE BOX TYLER/UNION
TO PREVENT DAMAGE
PLACED TO SIDE OF PIPE
TRACING WIRE TO BE
(CONTINUOUS) TYP
4 FOOT COIL OF TRACING WIRE
SHELDON BRONZE CO.
BRONZE DISK AS MFR BY
1/8" LETTERS CAST IN 3" DIA
TURNS TO OPEN
DIRECTION AND NO OF
* BV - BALL VALVE
* PV - PLUG VALVE
* BFV - BUTTERFLY VALVE
* GV - GATE VALVE
VALVE TYPE
VALVE SIZE
* RECLAIMED
* WASTEWATER
* WATER
SERVICE TYPE
OR "WATER" AS APPROPRIATE
LETTERS "RECLAIMED", "SEWER"
CAST IRON LID WITH RAISED
L-20
BFV
24"
WATER
CONCRETE PAD
1'-6" X 1'-6" X 6"
#3 BAR CONT, OC
WATER
1. PRECAST VALVE COLLARS SHALL NOT BE ALLOWED.
NOTE:
TIED TO PIPE
TRACING WIRE
ELSEWHERE
SHOULDER AND 2" ABOVE GRADE
PAD 1/4" BELOW GRADE IN PAVEMENT OR
SET COVER OF VALVE BOX AND CONCRETE
"RECLAIMED", ETC
"WATER", "SEWER",
W/ COVER MARKED
ADJUSTABLE CI VALVE BOX
BEDDING ROCK, NOT ON THE PIPE
CI VALVE BOX SHALL REST ON
C O
V E
R
6" MIN. (TYP)
12'
MORE COVER
DEPRESSED MAIN W/ 36" OR
TO OPERATING NUT ON
REQ'D TO MAINTAIN 2' DEPTH
VALVE STEM EXTENSION(S)
VALVE COLLAR (SEE DETAIL)
ANCHORED TO CONCRETE
DISK
VALVE IDENTIFICATION
4"9"
(SEE NOTE #3)
MANHOLE FRAME & COVER
GRADE
W/BACKWASH FEATURES
AIR VALVE ASSEMBLY
RINGS (TYP)
ADJUSTMENT 1
(M
A X
N O
M
IN
ADAPTER (IF REQ.)
(1/8" PER 1' MIN)
SLOPE DOWN TO MAIN
(SEE NOTE #4)
BRACKET
VALVE SUPPORT
(8" THK. MIN)
FLAT TOP SECTION
AND FITTINGS
316 SS PIPE
M
IN
V A
R
IE
S
6" MIN GRAVEL
G R
A V
E L B
O T
T O
M
(2" MIN, SEE NOTE #1)
OFF-SET PIPING "IF REQUIRED"
2" SS BALL VALVE
INTERIOR LINER. (SEE NOTE #2)
SECTION, NO BOTTOM. PROVIDE SPECIALTY
4' DIA OR 4 SQUARE MANHOLE (MIN) W/FLAT TOP
AIR VALVE ASSEMBLY INSIDE MANHOLE
LOW PROFILE
PIPE CONNECTIONS TO THE VALVE. (TYP)
PROVIDE RESTRAINED MJ ADAPTERS FOR HDPE 1.
NOTE:
2" SS BALL VALVE
5"
RESTRAINED PLUG
TAPPED OPENING,
PLUG WITH NPT
2" 316 SS NIPPLE
NEW PIPE
PLUG VALVE AND BOX DETAIL
SEE NOTE #6
(INSTALLED VERTICALLY NEAR MAIN). SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
THAN 2 INCH SIZE, PROVIDE A GATE VALVE TAPPING SLEEVE OR DUCTILE IRON TEE FITTING. ALSO, FOR OFF-SET PIPING LARGER
FOR A 2" AIR VALVE, PROVIDE 2" STAINLESS STEEL BALL VALVE AT THE MAIN. FOR AIR VALVES LARGER THAN 2" SIZE, PROVIDE A 6.
REQUIREMENTS.
A FLANGE GATE VALVE (WHEEL OPERATOR) OR PLUG VALVE. (LEVER ARM OPERATOR) SEE SPECIFICATION FOR ADDITIONAL
FOR PIPE SIZES 3 INCH AND SMALLER, PROVIDE A STAINLESS STEEL BALL VALVE (2" MIN). FOR PIPE SIZES 4 INCH AND LARGER, PROVIDE 5.
AND TO ASSURE A SOLID SUPPORT BRACKET.
" DIA X 2" LONG S/S ANCHOR (MIN). MODIFY THE ABOVE AS REQUIRED TO FIT SPECIFIC AIR VALVE 2
1CONCRETE MANHOLE WITH FOUR
" DIA TO ATTACH AROUND AIR VALVE. SECURE TO 8
5ATTACHING SURFACES), 3" ANGLE IRON FOR SUPPORT ARM AND TWO U-BOLTS
" THICK END PLATES (CONTOURED TO MATCH 8
3AND FABRICATED FROM ALL 316 STAINLESS STEEL MATERIALS AND INCLUDE 6" x 6" x
A VALVE SUPPORT BRACKET IS ONLY REQUIRED FOR ASSEMBLIES WHICH INCLUDE OFF-SET PIPING. THE BRACKET SHALL BE WELDED 4.
TIMES OR A SQUARE TOP WITH ALUMINUM DOOR SHALL BE PROVIDED (NON-TRAFFIC LOCATIONS ONLY).
NECESSARY FROM THE UNDER SIDE OF COVER). THE COVER (WHEN FLIPPED OPEN) MUST CLEAR THE AIR VALVE ASSEMBLY AT ALL
SEE DETAIL FOR FRAME AND COVER. THE COVER SHALL HAVE NO GASKET TO ALLOW AIR TO EXIT VAULT (REMOVE GASKET IF 3.
THE OUTSIDE SURFACES OF THE MANHOLE.
INCLUDING THE RISER SECTION TOP AND THE ADJUSTMENT RINGS. A BITUMINOUS WATERPROOFING MATERIAL SHALL BE PROVIDED ON
THE CONCRETE MANHOLE SHALL INCLUDE A POLYURETHANE SPECIALTY LINER TO BE INSTALLED ON THE INTERIOR SURFACES 2.
STAINLESS STEEL SCH.40, STD GRADE, THREADED.
IF OFF-SET PIPING IS REQUIRED, THE PIPING SHALL BE 2 INCH MINIMUM, (SAME SIZE AS AIR VALVE INLET). PIPING SHALL BE 316
THE AIR ASSEMBLY MANHOLE SHALL BE LOCATED OUTSIDE OF THE ROADWAY PAVEMENT AREA (I.E. LOCATED IN NON-TRAFFIC AREAS). 1.
NOTES:
IDENTIFICATION DISK DETAIL
VALVE COLLAR WITH
NTS
2" 316 SS PLUG
2" 316 SS NIPPLE
DI BLD FLG W/ 2" NPT
TAP FOR CONNECTION TO
EXPOSED FJ DI FITTING
SCHEDULE 40
2" V141
2" SS GATE VALVE (TYP)
2" 316 SS PIPE
AND FITTINGS (TYP)
2" V140
1" SS GATE VALVE (TYP)
1" BACKWASH HOSE
MFR
SEE BASE
FASTENERS
316 SS U-BOLT AND
SADDLE SUPPORT W/
ADJUSTABLE CI PIPE
B-LINE FIG B3092
SEE SADDLE MFR
PIPE
S
M
R
M A
X
M
M E
N S I O
N
B-LINE FIG 3088T
THREADED BASE STAND
ADHESIVE.
SECURE W/ HILTI HY150
BASE. EMBED 6" &
SIZED FOR MFR STD
(4) 316 SS ANCHORS
1-1/2" NON-SHRINK GROUT
SLABA
S
R
E Q
U I R
Nights and Weekends: XXX-XXXX
329-03468:30-5:00 Mon-Fri
For service/repair call:
PUBLIC WORKS DEPARTMENT
PUTNAM COUNTY
Property of
5"
EACH CORNER
FENCE GATE WITH CLF TIES AT
ATTACH SIGN TO PUMP STATION 2.
MATERIAL
DURABLE WEATHER-RESISTANT
ALL SIGNS TO BE MADE OF 1.
NOTE:
VACUUM RELIEF VALVES (SEWAGE)
COMBINATION AIR RELEASE AND
EMERGENCY CONTACT SIGN
TYPE 1 PIPE SUPPORT DETAIL
NTS
NTS
NTS
C-59
11/19/24 Manhole Detail FDOT RAI#1 - Air Valve Assembly Inside
Approved 2024-H-297-00293
11/19/2024reed02048 I:\23jobs\23L0104\CAD\Site\Sht62_STDDETAILS06.dgn2:57:40 PM
P.E. License No. 61786
Daryl R. Myers, P.E.
Engineer of Record:
Offices Nationwide
Jacksonville, Florida 32216-3685
8075 Gate Parkway West, Suite 204
Hanson Professional Services Inc.
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
C
SEPTIC TO SEWER PHASE IV
EAST PALATKA NO.
SHEET
STANDARD DETAILS
COMPACT UPPER 12" TO
DRY DENSITY, ASTM D-1557
TO MIN 95% MODIFIED PROCTOR
COMPACT REMAINDER OF TRENCH
MIN 98% MODIFIED PROCTOR
DRY DENSITY, ASTM D-1557
WITH SPECIFICATIONS
THICKNESS (6" MIN) IN ACCORDANCE
MATCH EXISTING BASE COURSE
UNDISTURBED EARTH
PAVEMENT (TYP)
SAW-CUT EXISTING
SOIL MATERIAL BACKFILL REQUIREMENTS
PIPE COVER DEPTH LIFT THICKNESS, AND
SEE TYPICAL PIPE TRENCH DETAIL FOR
EXISTING PAVEMENT
6"
6"
LIMITS OF PAVEMENT
RESTORATION
TRENCH
TOP WIDTH
6"
6"
EXISTING LIMEROCK OR DIRT
SOIL MATERIAL BACKFILL REQUIREMENTS
PIPE COVER DEPTH LIFT THICKNESS, AND
SEE TYPICAL PIPE TRENCH DETAIL FOR
LIMITS OF LIMEROCK
RESTORATION
TRENCH
TOP WIDTH
12"
COMPACTED LIMEROCK
12" THICK (MIN)
12"
UNDISTURBED EARTH
DRY DENSITY, ASTM D-1557
TO MIN 95% MODIFIED PROCTOR
COMPACT REMAINDER OF TRENCH
TYPE WITH SUPERPAVE
ASPHALT THICKNESS AND
MATCH EXISTING
2" THICKNESS (MIN) OR
DRY DENSITY, ASTM D-1557
98% MODIFIED PROCTOR
COMPACT UPPER 12" TO MIN
PATCHES, AND SIMILAR RESTORATION.
ROADS, DRIVEWAYS, PRIVATE ROADS, DRIVES, MISCELLANEOUS
ASPHALT PAVEMENT RESTORATION DETAIL APPLIES TO COUNTY 1.
NOTES:
3,000 PSI CONCRETE WITH
CONCRETE (TYP)
EXISTING THICKNESS (6" MIN)
SOIL MATERIAL BACKFILL REQUIREMENTS
PIPE COVER DEPTH LIFT THICKNESS, AND
SEE TYPICAL PIPE TRENCH DETAIL FOR
COMPACT UPPER 12" TO
COMPACT REMAINDER OF TRENCH
TO MIN 95% MODIFIED PROCTOR
DRY DENSITY, ASTM D-1557
MIN 98% MODIFIED PROCTOR
DRY DENSITY, ASTM D-1557
UNDISTURBED EARTH
6x6 #10 WWF, MATCH
DRIVE RESTORATION
LIMITS OF CONCRETE
SAW CUT EXISTING TRENCH
TOP WIDTH
CONCRETE RESTORATION DETAIL
SHALL BE 6 INCHES (MIN)
FROM CORNER. DOWEL EMBEDMENT DEPTH
BARS @ 2' OC AROUND PERIMETER 8" MIN
DRILL & DOWEL EXISTING CONCRETE W/ #4
12" 12"
MATCH EXISTING GRADE AND FINISH.1.
NOTES:
PULLING FORCE
ALLOWABLE BEND RADIUS AND
12" AND SMALLER FUSIBLE PVC PIPE
PIPE SIZE
MAXIMUM
ALLOWABLE BENDING
4"
6"
8"
10"
12"
RADIUS - Rs (FT)
PIPE INSERTION/
DRILL EXIT ANGLE
PIPE PULL HEAD
SWIVEL
DRILL STEM
MAXIMUM
ALLOWABLE PULLING
FORCE (DR18)
(K-LBS)
s
RESTORATION DETAIL
EXISTING SHARE USED PATH
LBR 40
STABILIZATION
12" TYPE B
1:4
0.02 0.06
12'
USE PATH
SHARED
2' LEVEL
4"
4"
2'
TYPE SP STRUCTURAL COURSE (TRAFFIC A) (1")
OPTIONAL BASE GROUP 6 WITH
1:
LIMEROCK RESTORATION DETAIL
ASPHALT PAVEMENT RESTORATION DETAIL
NTS
NTS
NTS
NTS
C-62
11/19/24 Restoration Detail FDOT RAI#1 - Existing Shared Use Path
Approved 2024-H-297-00293
11/19/2024reed02048 I:\23jobs\23L0104\CAD\Site\Sht64_PH_IV_SWPPP01.dgn2:57:41 PM
P.E. License No. 61786
Daryl R. Myers, P.E.
Engineer of Record:
Offices Nationwide
Jacksonville, Florida 32216-3685
8075 Gate Parkway West, Suite 204
Hanson Professional Services Inc.
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
C
SEPTIC TO SEWER PHASE IV
EAST PALATKA NO.
SHEET
be under the contract lump sum price established quality requirements. The barrier type(s) will
Turbidity barriers for flowing streams and tidal the Engineer.
in vertical position unless otherwise directed by
Posts in staked turbidity barriers to be installed in the bid proposal for Erosion & Sediment Control specified in the plans, however payment will be at the Contractors option unless otherwise conditions and meet erosion control and water or any combinations of types that will suit site creeks may be either floating, or staked types
Note:
THIS COMPLIANCE SHALL BE PART OF THE CONTRACT.
SJRWMD FOR EROSION AND SEDIMENTATION CONTROL. THE COST OF
MANAGEMENT DISTRICT INQUIRIES, RELATIVE TO COMPLIANCE OF
33. THE CONTRACTOR SHALL BE REQUIRED TO RESPOND TO ALL WATER
WATER MANAGEMENT DISTRICT.
REQUIRES A CONSUMPTIVE USE PERMIT FROM THE ST. JOHNS RIVER
29. DEWATERING PUMPS SHALL NOT EXCEED THE CAPACITY OF THAT WHICH
TRANSPORTATION OF SUSPENDED SOLIDS TO THE RECEIVING OUTFALL.
CONVEYED TO THE OUTFALL IN A MANNER WHICH PREVENTS EROSION AND
28. ANY DISCHARGE FROM DEWATERING ACTIVITY SHALL BE FILTERED AND
MAINTAINED.
EROSION PROTECTION TO ENSURE WATER QUALITY STANDARDS ARE
27. SOD SHALL BE PLACED IN AREAS WHICH MAY REQUIRE IMMEDIATE
MAINTAINED UNTIL A PERMANENT VEGETATIVE COVER IS ESTABLISHED.
26. ALL DISTURBED AREAS SHALL BE GRASSED, FERTILIZED, MULCHED AND
CONSTRUCTION.
WATER QUALITY DEGRADATION. SEE DETAIL SHEET FOR TYPICAL
TO ALL WETLAND AREAS WHERE THERE IS POTENTIAL FOR DOWNSTREAM
25. EROSION AND SEDIMENT CONTROL BARRIERS SHALL BE PLACED ADJACENT
DEPARTMENT OF ENVIRONMENTAL REGULATION (F.D.E.R.) CHAPTER 6.
LAND AND WATER MANAGEMENT" FROM THE STATE OF FLORIDA
REFER TO "THE FLORIDA DEVELOPMENT MANUAL - A GUIDE TO SOUND
24. FOR ADDITIONAL INFORMATION ON SEDIMENT AND EROSION CONTROL
SPECIFICATIONS AND CRITERIA.
SPECIFICATIONS AND ST. JOHNS RIVER WATER MANAGEMENT DISTRICT
AND SEDIMENT CONTROL PRACTICES AS OUTLINED IN THE PLANS,
23. THE CONTRACTOR IS RESPONSIBLE FOR FOLLOWING THE BEST EROSION
NOT ERODE.
DEPOSITED IN A SUITABLE AREA AND IN SUCH A MANNER THAT IT WILL
THE DESIGN DEPTH OF THE TRAP. REMOVED SEDIMENT SHALL BE
ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO 1/3
22. SEDIMENT SHALL BE REMOVED AND THE TRAP RESTORED TO ITS
MADE AS NEEDED.
21. THE STRUCTURE SHALL BE INSPECTED AFTER EACH RAIN AND REPAIRS
CONFORM WITH THE EXISTING GRADE, PREPARED AND SEEDED.
OR FILTER BARRIER IS NO LONGER REQUIRED SHALL BE DRESSED TO
20. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE
THIRD THE HEIGHT OF THE BARRIER.
THEY MUST BE REMOVED WHEN DEPOSITS REACH APPROXIMATELY ONE-
19. SEDIMENT DEPOSITS SHOULD BE REMOVED AFTER EACH STORM EVENT.
REPLACED PROMPTLY.
LIFE AND THE BARRIER STILL BE NECESSARY, THE FABRIC SHALL BE
OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE
18. SHOULD THE FABRIC ON A SILT FENCE OR FILTER BARRIER DECOMPOSE
RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY.
AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED
17. SILT FENCES AND FILTER BARRIERS SHALL BE INSPECTED IMMEDIATELY
THE EXISTING GRADE, PREPARED AND SEEDED.
BARRIER IS NO LONGER REQUIRED SHALL BE DRESSED TO CONFORM TO
16. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE STRAW BALE
ACCOMPLISHED PROMPTLY.
15. NECESSARY REPAIRS TO BARRIERS OR REPLACEMENT OF BALES SHALL BE
END RUNS AND UNDERCUTTING BENEATH BALES.
14. CLOSE ATTENTION SHALL BE PAID TO THE REPAIR OF DAMAGED BALES,
RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL.
13. STRAW BALE BARRIERS SHALL BE INSPECTED IMMEDIATELY AFTER EACH
FROM ENTERING BETWEEN BALES.
12. LOOSE STRAW SHOULD BE WEDGED BETWEEN BALES TO PREVENT WATER
LEAST TWO STAKES OR REBARS DRIVEN THROUGH THE BALE.
11. EACH BALE SHALL BE SECURELY ANCHORED AND HELD IN PLACE BY AT
BACKFILLED AND COMPACTED AGAINST THE FILTER BARRIER.
AFTER THE BALES ARE STAKED, THE EXCAVATED SOIL SHALL BE
TRENCH SHALL BE EXCAVATED TO A MINIMUM DEPTH OF 8 INCHES.
10. THE FILTER BARRIER SHALL BE ENTRENCHED AND BACKFILLED. A
THE INLET, WITH THE ENDS OF ADJACENT BALES PRESSED TOGETHER.
9. BALES SHALL BE PLACED LENGTHWISE IN A SINGLE ROW SURROUNDING
THE BALES.
BINDINGS ORIENTED AROUND THE SIDES RATHER THAN OVER AND UNDER
8. BALES SHALL BE EITHER WIRE-BOUND OR STRING-TIED WITH THE
PULLED AWAY FROM THE INLET, CLEANED AND REPLACED.
NO LONGER ADEQUATELY PERFORMS ITS FUNCTION, THE STONES MUST BE
7. IF THE STONE FILTER BECOMES CLOGGED WITH SEDIMENT SO THAT IT
ALL SIDES.
SHALL EXTEND BEYOND THE INLET OPENING AT LEAST 18 INCHES ON
LEAST 12 INCHES OVER THE ENTIRE INLET OPENING. THE STONE
AS INDICATED IN D-903. THE DEPTH OF STONE SHALL BE AT
6. FDOT NO. 1 COARSE AGGREGATE SHALL BE PLACED OVER THE WIRE MESH
IS NECESSARY, THE STRIPS SHALL BE OVERLAPPED.
INCH OPENINGS SHALL BE USED. IF MORE THAN ONE STRIP OF MESH
STRUCTURE. HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2-
EXTENDS A MINIMUM OF 1 FOOT BEYOND EACH SIDE OF THE INLET
5. WIRE MESH SHALL BE LAID OVER THE DROP INLET SO THAT THE WIRE
ACCEPTANCE.
ETC. ARE CLEANED OUT AND WORKING PROPERLY AT TIME OF
4. CONTRACTOR SHALL INSURE THAT ALL DRAINAGE STRUCTURES, PIPES,
PROJECT CONFINES DUE TO UNSEEN CONDITIONS OR ACCIDENTS.
ABOVE MUST BE PROVIDED THAT WILL NOT PERMIT SILT TO LEAVE THE
3. ADDITIONAL PROTECTION - ON-SITE PROTECTION IN ADDITION TO THE
CONSTRUCTION AND ONLY WHEN AREAS HAVE BEEN STABILIZED.
EROSION AND SEDIMENT CONTROL DEVICES AFTER COMPLETION OF
2. THE SITE CONTRACTOR IS RESPONSIBLE FOR REMOVING THE TEMPORARY
ALL DITCHES AND SWALES AT COMPLETION OF CONSTRUCTION.
NOT REUSABLE ON-SITE AND ASSURING PLAN ALIGNMENT AND GRADE IN
1. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING SILT FROM SITE IF
30. ALL DISTURBED AREAS TO BE STABILIZED THROUGH COMPACTION, SILT
SCREENS, HAY BALES, AND GRASSING. ALL FILL SLOPES 3:1 OR
STEEPER TO RECEIVE STAKED SOLID SOD.
31. ALL DEWATERING, EROSION, AND SEDIMENT CONTROL TO REMAIN IN
PLACE AFTER COMPLETION OF CONSTRUCTION AND REMOVED ONLY WHEN
AREAS HAVE STABILIZED.
32. THIS PLAN INDICATES THE MINIMUM EROSION AND SEDIMENT
MEASURES REQUIRED FOR THIS PROJECT. THE CONTRACTOR IS
RESPONSIBLE FOR MEETING ALL APPLICABLE RULES, REGULATIONS
AND WATER QUALITY GUIDELINES AND MAY NEED TO INSTALL
ADDITIONAL CONTROLS.
TO BE USED AT SELECTED SITES WHERE THE
BARRIERS FOR FILL SLOPES
DITCH INSTALLATIONS AT
PROTECTION AROUND INLETS OR SIMILAR STRUCTURES
DITCH BOTTOM INLETCOMPLETED INLET
BALES BACKED BY FENCE
PARTIAL INLET
ELEVATION
PLAN
ELEVATION
PLAN
Ditch
Sod
Cross Drain
Ditch Bottom Inlet
Sod
Silt Barrier
Limits Of Construction
50' Max. 50' Max.
50' Max.50' Max.
10' (Typ.)
Endwall
C
HAY BALE LOCATION
(D-901)
N.T.S.
DRAINAGE STRUCTURES
TYPE ITYPE II
Per Ft. Buoyancy)
4. Navigation may require segmenting barrier during construction operations.
3. Deployment of barrier around pile locations may vary to accommodate construction operations.
2. Number and spacing of anchors dependent on current velocities.
1. Turbidity barriers are to be used in all permanent bodies of water regardless of water depth.
5. For additional information see Section 104 of the FDOT Standard Specifications.
D
D
D
FLOATING TURBIDITY BARRIERS
LEGEND
TURBIDITY BARRIER APPLICATIONS
NOTES:
Stress Plate
N.T.S.
(D-907)
TURBIDITY BARRIERS
Type III Silt Fence
Silt Fence
FDOT Spec.)
Poultry Mesh (20. Ga. Min.)
Or Type A Fence Fabric
(Index No. 452 & Sec. 985
Type A Fence Fabric
Poultry Mesh Or
3"Min. Dia.
i n
Optional Post Positions
V e r t i c a l
Filter Fabric
Silt Flow
Principle Post Position
Wood; Steel
SECTIONELEVATION
10' Max.
Filter Fabric (In
Conformance With
1.33 Lbs/Ft. Min.)
Sec. 985 FDOT Spec.)
TYPE IV SILT FENCE
20̂
(Canted 20^ Toward Flow) r o r e
Silt Flow
Type IV Silt Fence
Sheet 2 of 3, FDOT Index No. 102.
Note: Spacing for Type III & TYPE IV Fence to be in accordance with Chart 1, Sheet 1 of 3, FDOT Index
No. 102 and ditch installations at drainage structures
SILT FENCE APPLICATIONS
used at permanent bodies of water.
watercourses. Silt fences are to be used at upland locations and turbidity barriers
Do not deploy in a manner that silt fences will act as a dam across permanent flowing
Type III Or Type IV Silt Fence Protection
Around Ditch Bottom Inlets.
Si lt F lo w
Silt Flow
Type III or Type IV
20̂
TYPE III SILT FENCE
6' Max.
ELEVATION
SECTION
V e r t i c a l i n
N.T.S.
(D-908)
SILT FENCE TYPE III & IV
M i n
NOTICE:
COMPONENTS OF TYPES I & TYPE II MAY
BE SIMILAR OR IDENTICAL TO PROPRIETARY
DESIGNS. ANY INFRINGEMENT ON THE
PROPRIETARY RIGHTS OF THE DESIGNER
SHALL BE THE SOLE RESPONSIBILITY OF
THE USER. SUBSTITUTIONS FOR TYPES
I AND II SHALL BE AS APPROVED BY
THE ENGINEER.
PVC Fabric (300 psi Test) With Lacing Grommets
18 Oz. Nylon Reinforced Strength)
(600 lb. Breaking
Polypro Rope
Galvanized Chain Galvanized Chain
Per Ft. Buoyancy)
Flotation (6" Dia. Equiv.) (12 Lbs.
Closed Cell Solid Plastic Foam
Galvanized Connectors (Tool Free Disconnect) (9800 Lbs. Breaking Strength) With
Vinyl Sheathed EAW Steel Cable
Closed Cell Solid Plastic Foam
Flotation (8" Dia. Equiv.) (17 lbs.
(Metal Collar Reinforced)
Slotted PVC Connector Pipe
Type A Or B Fence
Note: Bales to be staked at the direction of the Engineer.
Loose Soil Placed By Shovel And
Lightly Compacted Along Upstream
Face Of Bales.
Anchor Bales With 2 - 2" x 2" x 4'
Stakes Per Bale.
DitchDitch Curb & GutterCurb & Gutter
Sidewalk
Apron
Riser Open
50' On Centers ( Typ. )
Overlap Ends
Stakes Per Bale.
Anchor Bales With 2 - 2" x 2" x 4'
Silt Barrier
50' Max.50' Max.
Limits Of Construction
18 Oz. Nylon Reinforced
PVC Fabric (300 psi Test)
Pile Locations
Dredge Or Fill Area
Mooring Buoy w/Anchor
Anchor
To Current Action
Barrier Movement Due
Structure Alignment
Shore Line
Proposed Toe Of Slope
Ty pi ca l
0'
T y p i c a l
Causeway
Existing
Typ ica l
Current
Fill Slope
Compacted Along The Upstream Edge Of Bales.
Loose Soil Placed By Shovel And Lightly
Anchor Bales With 2 - 2" x 2" x 4'
Stakes Per Bale.
Silt Barrier
Limits Of Const.
Shore Line Limits Of Const.
S t r e a m
T i d a l e e k
Shore Line
Turbidity Barriers r e
1.33 Lbs/Ft. Min.)
Min. Dia. Wood; Steel
Post (Options: 2" x 4" Or
18 Oz. Nylon Reinforced
PVC Fabric (300 psi Test)
6' Max.
T y p i c a l
Fill Slope
NATURAL GROUND SLOPES AWAY FROM THE TOE OF SLOPE
6' Min.
Bales To Butt
Flow
As Required
F l o w
S w a l e
L Median Ditch
NATURAL GROUND SLOPES TOWARD THE TOE OF SLOPE
TO BE USED AT SELECTED SITES WHERE THE
Sod
Post (Options: 2" x 4" Or
Min. Dia.
1.33 Lbs/Ft. Min.)
Wood; Steel
Optional Post Positions Principle Post Position
(Canted 20^ Toward Flow)
Filter Fabric
Silt Flow
Sec. 985 FDOT Spec.)
Conformance With
Filter Fabric (In r e
Post (Options: 4" x 4" Or
Silt Fence to be paid for under the contract lump sum price for Erosion and Sediment Control.
Note:
EROSION & SEDIMENT CONTROL NOTES
EROSION CONTROL NOTES AND DETAILS C-64
11/19/24 FDOT RAI#1 - Erosion Control Notes and Details
Approved 2024-H-297-00293
/6 /2
:2
:5
P M
R E
V
IS
IO
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2023-24 SHEETINDEX
Median
11102-601
TWO-LANE AND MULTILANE ROADWAY,
WORK BEYOND THE SHOULDER11/01/20
c. 15' or more from the traveled way.
b. More than 2' behind the curb,
a. Behind an existing barrier, Offset Zone:
SYMBOLS:NOTES:
Work Area
Lane Identification and Direction of Traffic
3. Use Index 102-660 when Work Area encroaches a Sidewalk.
vehicles cross the Offset Zone in any one hour period.
and terminating the work area) requires that two or more work
2. Use Index 102-602 when the work operation (excluding establishing including Medians of divided roadways, with work beyond the shoulder.
1. This Index applies to Two-Lane, Two-Way and Multilane Roadways, MULTILANE ROADWAY SHOWN, TWO-LANE ROADWAY SIMILAR
Approved 2024-H-297-00293
/6 /2
:2
:3
P M
R E
V
IS
IO
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2023-24 SHEETINDEX
DETOUR
DETOUR
DETOUR
DETOUR
DETOUR
DETOUR
R9-11AL
PEDESTRIAN DETOUR
(See Note 4)
R9-10
(See Notes 4 and 5)
Advance Closure LCD
(See Notes 4 and 5)
Advance Closure LCD
AHEAD
WORK
ROAD
W20-1F
AHEAD
WORK
ROAD
CROSS HERE
AHEAD
SIDEWALK CLOSED
CROSS HERE
AHEAD
SIDEWALK CLOSED
CLOSED
SIDEWALK
USE OTHER SIDE
SIDEWALK CLOSED
USE OTHER SIDE
SIDEWALK CLOSED
21102-660
SIDEWALK CLOSURE
11/01/20
M4-9BR
M4-9BL
M4-9BL
M4-9BR
R9-11AR
M4-9BL
M4-9BR
(See Note 4)
R9-10
(See Note 4)
R9-9
W20-1F
SYMBOLS:
Work Area
NOTES:
facilities (e,g,, transit stops, residences, or business entrances).
5. Omit the Advance Closure LCD if it blocks access to other pedestrian in accordance with the manufacturer's instructions.
4. "Sidewalk Closed" signs (R9-XX) may be mounted on pedestrian LCDs panel to the surface of the sidewalk.
maintain a minimum 7’ clearance from the bottom of the sign
3. For post mounted signs located near or adjacent to a sidewalk,
2. Place pedestrian LCDs across the full width of the closed sidewalk.
closed crosswalks.
1. Cover or deactivate pedestrian traffic signal display(s) controlling
Work Zone Sign
Lane Identification and Direction of Traffic
Pedestrian Longitudinal Channelizing Device (LCD)
Approved 2024-H-297-00293
/2
/2
:1
:1
A
M
R E
V
IS
IO
N DESCRIPTION:
REVISION
LAST
ofSTANDARD PLANS
FY 2023-24 SHEETINDEX
C C
Existing Sidewalk
Existing Sidewalk
Temporary Barrier
6" White
W20-1F
AHEAD
WORK
ROAD
W20-1F
AHEAD
WORK
ROAD
W20-5
AHEAD
CLOSED
RIGHT LANE
Note 4)
(See General
MOT-13-06
PRESENT
WHEN WORKERS
DOUBLED
SPEEDING FINES
W4-2
ROAD WORK
END
(See Note 4)
G20-2
Existing Sidewalk
6" White
W20-1F
AHEAD
WORK
ROAD
W20-5
AHEAD
CLOSED
RIGHT LANE
Note 4)
(See General
MOT-13-06
PRESENT
WHEN WORKERS
DOUBLED
SPEEDING FINES
W4-2
ROAD WORK
END
(See Note 4)
G20-2
M in
C C
22102-660
SIDEWALK CLOSURE
11/01/21
PEDESTRIAN SPECIAL DETOUR
(Temporary Barrier Shown, Low Profile Barrier Similar)
PEDESTRIAN DIVERSION - OPTION 1
(Work Zone Speed 35 mph or Less)
PEDESTRIAN DIVERSION - OPTION 2
100'
100'
B XLXXXX
X
B XLXXXX
Merge
Arrow Board Mode:
Merge
Arrow Board Mode:
SYMBOLS:
NOTES:
Temporary Pedestrian Way
Work Area
Pedestrian Longitudinal Channelizing Device (LCD)
Work Zone Sign
Channelizing Device (See Index 102-600)
Lane Identification and Direction of Traffic
Arrow Board
Crash Cushion
Plans or as approved by an Engineer.
5. Pedestrian Diversion Option 2 may only be used when called for in the hours or less.
distances, may be omitted when the work operation will be in place for 24 and "End Road Work" signs (G20-2), along with associated work zone sign
4. The "Speeding Fines Doubled When Workers Present" signs (MOT-13-06) for curb ramps diverting pedestrian traffic into a closed lane.
requirements of Index 522-002. Detectable warnings are not required
3. When temporary pedestrian ways require curb ramps, meet the
5' in width at intervals not to exceed 200'.
Provide a 5' x 5' passing space for temporary pedestrian ways less than of 0.02, except where space restrictions warrant a minimum width of 4'.
2. Provide a 5' wide temporary pedestrian way with a maximum…
This is the start of the file's text. The full file is on GovTribe.