Appendix I - Construction Drawings and Pictures (bjones) CS# 26-10.pdf
PDF 1 MB Posted
- Solicitation number
- BPM058800
- Issued by
- Calvert County, Maryland
About this file
Appendix I - Construction Drawings and Pictures
This appendix comprises construction drawings and visual documentation for home accessibility modifications being procured by the Maryland State Department of Education, Division of Rehabilitation Services (MSDE, DORS) for a designated client under contract CS #26-10. The document serves as a technical reference for general contractors bidding on this Certified Small Business (CSB) designated procurement, providing detailed architectural plans, specifications, and photographic materials that illustrate the scope of residential construction work required. The drawings and pictures establish the physical parameters, design requirements, and existing conditions that contractors must address in their bids and project execution.
The appendix functions as essential contract documentation that ensures bidders have comprehensive visual and technical information necessary to prepare accurate proposals and perform the accessibility modifications work. As a CSB-designated procurement, this contract opportunity is reserved exclusively for small businesses certified under Maryland's program. The construction drawings and accompanying photographs provide the baseline information from which contractors can assess site conditions, material requirements, labor scope, and timeline considerations for completing the home modifications to meet the client's accessibility needs.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
PROJECT LOCATION
PRELIMINARY
NOT FOR
CONSTRUCTION
ARCHITECT
SET NO.
Revision
Copyright PRIME AE Group, Inc.
C
(410) 654-3790
LOCATION MAP KEY MAP
G-001 250877
TITLE SHEET
Issue Date
MSDE HOME ACCESSIBILITYMSDE HOME ACCESSIBILITY
MODIFICATION PLAN - B. JONESMODIFICATION PLAN - B. JONES
7850 Pine Boulevard Lusby, MD 20657
MARYLAND STATE DEPARTMENT OF EDUCATIONMARYLAND STATE DEPARTMENT OF EDUCATION
DIVISION OF REHABILITATION SERVICES (DORS)DIVISION OF REHABILITATION SERVICES (DORS)
Project Status
5521 Research Park Drive Suite 300 Baltimore, MD 21228
No Date Description
GENERAL DIMENSIONING
NOTE: THE ± INDICATES A DIMENSION THAT
CAN VARY. (NOTIFY THE ARCHITECT OF ANY
CHANGE IN THAT DIMENSION IF IT IS GREATER
THAN 1")
NOTE: DIMENSIONS ARE TAKEN FROM/TO
FACE OF STUD OR CMU, UNLESS
OTHERWISE NOTED.
FACE OF SURFACE INDICATORO'-O"
O'-O" ±
DOOR
NUMBER
ROOM NUMBER
SHEET NUMBER
DETAIL
NUMBER
ROOM NAME
X WINDOW/CURTAIN
WALL
CODED NOTE
TOILET ACCESSORY
MATERIAL FINISH
Material
22'-10" CEILING HEIGHT TAG
INTERIOR
PARTITION
EQUIPMENT
A101
X.#
A-XXX
A101
A101
A101
A101
__________ 1
A101
__________BUILDING SECTION
WALL SECTION
DETAIL CALLOUT
DETAIL SECTION
Name Elevation 1
NORTH ARROW
LEVEL
INTERIOR ELEVATION
EXTERIOR ELEVATION
REVISION
STARTING POINT
ALIGN CONSTRUCTION
WORK ABOVE,
BEYOND OR TO BE
REMOVED
NEW DOOR
A
CENTER LINE/
ELEVATION LINE
EXISTING DOOR
NEW STRUCTURAL GRID
EXISTING STRUCTURAL GRID
SYMBOL LEGEND
N
A101
TA-XX
XX
FIRE RATED
INTERIOR PARTITION
X.# R#
A101
X
X
X
X
MATERIAL LEGEND
ALUMINUM NON-FOAM
INSULATION BOARD
UNDISTURBED EARTH/
COMPACT FILL
CONCRETE/ PRECAST
CONCRETE
CMU PLYWOOD GYPSUM BOARD POROUS FILL GRAVEL
FINISHED WOOD FOR
ARCH WOODWORK
RIGID INSULATION ACOUSTICAL CEILING
BOARD
SEMI-RIGID MINERAL
FIBER INSULATION
BRICK RESILIENT FLOORING STEEL PORCELAIN TILE
SAND/ MORTAR/
PLASTER/ CUT STONE
SPRAY FOAM
INSULATION
BATT INSULATION/
LOOSE FILL INSULATION
FOAM CONCRETE FILL
LATH AND PLASTER EXISTING TO REMAIN
GENERAL NOTES
1.
2.
3.
4.
DO NOT SCALE DRAWINGS, IF DIMENSIONS ARE IN QUESTION, CONTACT THE ARCHITECT.
CONTRACTOR SHALL PROVIDE AS-BUILT INFORMATION ON ALL CONDITIONS INSTALLED SIGNIFICANTLY
DIFFERENT FROM THOSE DETAILED IN THESE DOCUMENTS.
SECURE ALL CONSTRUCTION AT ALL TIMES.
THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SAFE USE OF PRODUCTS ON THE SITE. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS TO PRODUCE THE WORK INCLUDING ALL SAFETY MEASURES TO PROTECT THEIR STAFF. THE CONTRACTOR WILL FURNISH TO THE OWNER MSDS SHEETS ON MATERIAL KNOWN OR THAT MIGHT BE CONSIDERED NOXIOUS OR HAZARDOUS TO
BE USED IN THE CONSTRUCTION WORK.
ABBREVIATIONS
@ - AT, (AT THE RATE OF)
- ANGLE - CHANNEL
- POUNDS
- PARALLEL
- SQUARE
- PERPENDICULAR
- DEGREESXX
or
A.F.F.
ACT
A.P.
ADD
ADDL
ADJ
A/C
ALT
ALUM
A.B.
ANOD
APPROX
A/E
ARCH
AESS
A.D.
ASSY
AUTO
AVG
BRG
BM
BLW
BLKG
BD
B.O.
CPT
CLKG
CLG
CEM
C.T.
CLR
CFMF
COL
CONC
C.M.U.
CONST
CONT
CONTR
C.J.
COORD
CNTR
C.W.
DEMO
DTL/ DET
DIA
DIM
DBL
DN
DS
DWG.(S)
D.F.
EA.
ELEC
E.W.C.
EL
ELEV
EQ. or =
EQP
EXH
EXIST
E.J.
EXP
EXT
F.O.F.
F.O.M.
F.O.S.
FT.(')
F.V.
FIN
F.F.
F.F.E.
F.E.
F.E.C.
F.H.C.
F.G.
- ABOVE FINISHED FLOOR
- ACOUSTICAL CEILING TILE
- ACOUSTICAL PANEL
- ADDENDUM (ADDENDA)
- ADDITIONAL
- ADJUSTABLE (ADJACENT)
- AIR CONDITIONING
- ALTERNATE
- ALUMINUM
- ANCHOR BOLT
- ANODIZED
- APPROXIMATE(LY)
- ARCHITECT OR ENGINEER
- ARCHITECT(URAL)
- ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
- AREA DRAIN
- ASSEMBLY
- AUTOMATIC
- AVERAGE
- BEARING
- BEAM
- BELOW
- BLOCKING
- BOARD
- BOTTOM OF
- CARPET
- CAULKING
- CEILING
- CEMENT
- CENTER LINE
- CERAMIC TILE
- CLEAR
- COLD FORMED METAL FRAMING
- COLUMN
- CONCRETE
- CONCRETE MASONRY UNIT
- CONSTRUCT(ION)
- CONTINUOUS(ATION)
- CONTRACT(OR)
- CONTROL JOINT
- COORDINATE(ION)
- COUNTER
- CURTAIN WALL
- DEMOLITION
- DETAIL(S)
- DIAMETER
- DIMENSION(ED)
- DOUBLE
- DOWN
- DOWNSPOUT
- DRAWING(S)
- DRINKING FOUNTAIN
- EACH
- ELECTRIC(AL)
- ELECTRIC WATER COOLER
- ELEVATION
- ELEVATOR
- EQUAL
- EQUIPMENT
- EXHAUST
- EXISTING
- EXPANSION JOINT
- EXPOSED (EXPANSION)
- EXTERIOR
- FACE OF FINISH
- FACE OF MASONRY
- FACE OF STUD(S)
- FOOT (FEET)
- FIELD VERIFY
- FINISH(ED)
- FINISH FLOOR
- FINISH FLOOR ELEVATION
- FIRE EXTINGUISHER
- FIRE EXTINGUISHER CABINET
- FIRE HOSE CABINET
- FINISH GRADE
FL/ FLR
F.D.
F.R.T.W.
FTG
FDN
FURN
FURR
GALV
GA
G.C.
GL
G.B.
GT
GYP BD
GWB
HDW
HRDWD
HVAC
HT
HP
H.C.
H.M.
HORIZ
H.B.
HR
IN (")
INCL
I.D.
INSUL
INT
JAN
JT
JST
KO.
LVL
LAV
L.F.
LIN
MAN
MFR
MAS
M.O.
MATL
MAX
MECH
MBR
MTL
MEZZ
MIN
MISC
MLD'G
MTD
MTG
NOM
N.A.
N.I.C.
N.T.S.
NO. (#)
O.C.
OPNG
ORIG
O/O O.D.
OH
OA
OVHD
PTD./ PT
PR
PLAM
PLUMB
PLYWD
LB or #
- FLOOR(ING)
- FLOOR DRAIN
- FIRE RETARDANT TREATED WOOD
- FOOTING
- FOUNDATION
- FURNITURE
- FURRING
- GALVANIZE(D)
- GAUGE
- GENERAL CONTRACT(OR)
- GLASS (GLAZING)
- GRAB BAR
- GROUT
- GYPSUM BOARD
- GYPSUM WALLBOARD
- HARDWARE
- HARDWOOD
- HEATING/ VENTILATING/ AC
- HEIGHT
- HIGH POINT
- HOLLOW CORE
- HOLLOW METAL
- HORIZONTAL
- HOSE BIBB
- HOUR
- INCH(ES)
- INCLUDE(D), (ING)
- INSIDE DIAMETER/ DIMENSION
- INSULATE(D), (ION)
- INTERIOR
- JANITOR
- JOINT
- JOIST
- KNOCKOUT
- LAMINATED VENEER LUMBER
- LAVATORY
- LINEAR FOOT (FEET)
- LINEAR
- MANUAL
- MANUFACTURE(R)
- MASONRY
- MASONRY OPENING
- MATERIAL
- MAXIMUM
- MECHANICAL
- MEMBER
- METAL
- MEZZANINE
- MINIMUM
- MISCELLANEOUS
- MOULDING
- MOUNT(ED)
- MOUNTING
- NOMINAL
- NOT APPLICABLE
- NOT IN CONTRACT
- NOT TO SCALE
- NUMBER
- ON CENTER
- OPENING
- ORIGINAL
- OUT TO OUT
- OUTSIDE DIAMETER / DIMENSION
- OPPOSITE HAND
- OVERALL
- OVERHEAD
- PAINTED
- PAIR
- PLASTIC LAMINATE
- PLUMBING
- PLYWOOD
- POUND(S)
P.S.F.
P.S.I.
PREFAB
PREFIN
PRELIM
PREP
PROJ
PROP
Q.T.
QTY
REF
REINF
REM
REQ(D)
RES
RG
REV
R R.D.
R.V.
RM.
R.O.
SAN
SCHED
SC
SECT
SHT
SIM
SPEC(S)
SQ.
S.F.
S.S.
STD
STL
STL FR
STRUCT
SG
SUSP
TEMP
THRU
T & G T & B T.O.B.
T.C.
T.O.C.
T.O.M.
T.O.S.
T.O.W.
T
TYP
UNF
UNO
UR
V.B.
VNR
V.T.R.
VERT
VEST
VIN
V.C.T.
V.W.C.
WC
WT.
W.W.F.
WIN
W/ W/O
WD
WP
- POUNDS PER SQUARE FOOT
- POUNDS PER SQUARE INCH
- PREFABRICATED
- PREFINISHED
- PRELIMINARY
- PREPARATION
- PROJECT (PROJECTION)
- PROPERTY
- QUARRY TILE
- QUANTITY
- REFERENCE
- REINFORCE(ING), (D)
- REMOVABLE
- REQUIRE(D)
- RESILIENT FLOORING
- RETURN GRILLE
- REVISE(ION), (ED)
- RISER
- ROOF DRAIN
- ROOF VENT
- ROOM
- ROUGH OPENING
- SANITARY
- SCHEDULE(D)
- SEALED CONCRETE
- SECTION
- SHEET
- SIMILAR
- SPECIFICATION(S)
- SQUARE
- SQUARE FOOT (FEET)
- STAINLESS STEEL
- STANDARD
- STEEL
- STEEL FRAME
- STRUCTURE(AL)
- SUPPLY GRILLE
- SUSPENDED
- TEMPORARY
- THROUGH
- TONGUE AND GROOVE
- TOP AND BOTTOM
- TOP OF BEAM
- TOP OF CURB
- TOP OF CONCRETE
- TOP OF MASONRY
- TOP OF STEEL
- TOP OF WALL
- TREAD
- TYPICAL
- UNFINISHED
- UNLESS NOTED OTHERWISE
- URINAL
- VAPOR BARRIER
- VENEER
- VENT THROUGH ROOF
- VERTICAL
- VESTIBULE
- VINYL
- VINYL COMPOSITION TILE
- VINYL WALL COVERING
- WATER CLOSET
- WEIGHT
- WELDED WIRE FABRIC
- WINDOW
- WITH
- WITHOUT
- WOOD
- WORK POINT
(NOT ALL ABBREVIATIONS USED)
CL
Revisions:
Copyright PRIME AE Group, Inc.
C
Sheet Issue Date:
APPROVALS CONSTRUCTION DOCUMENT
DIVISION OF REHABILITATION SERVICES
WORKFORCE TECHNOLOGY CENTER
REHABILITATION TECHNOLOGY SERVICES
2301 ARGONNE DRIVE, BALTIMORE MD 21218
PAM POST, SUPERVISOR - TEL. 443-236-7625
OWNER
OWNER
5/
/2
2:
:0
PM
G-002 250877
ABBREVIATIONS,
SYMBOLS, GENERAL
NOTES, AND SHEET
INDEX
P in e Bo ul ev ar d
Lu sb y, M
D
M
SD
E H
O M
E A
C C
ES
SI
B
IL
IT
Y
M O
D
IF
IC
A
TI
O
N P
LA
N
B
. J O
N
ES
01 G
EN
ER
AL
Project Status
Issue Date
03/31/22
R es ea rc h Pa rk D riv e
Su ite
B al tim or e, M
D
G-001 TITLE SHEET
G-002 ABBREVIATIONS, SYMBOLS, GENERAL
NOTES, AND SHEET INDEX
A-101 FIRST FLOOR PLAN
A-521 INTERIOR DETAILS
SAVE PAGE
GENERAL
STRUCTURAL
ARCHITECTURAL
PLUMBING
MECHANICAL
ELECTRICAL
SHEET INDEX
No. Date Description
A-1013
A-1013
2'
4" 3'
0"
EXISTING MIRROR/MEDICINE
CABINET TO REMAIN
NEW ACCESSIBLE SINK/FAUCET -
INSTALL TO EXISTING PIPING
NEW 24" GRAB BAR - CENTER ON
EXISTING TOILET
NEW ROLL-IN SHOWER
ENCLOSURE. PROVIDE GRAB
BARS AND ACCESSIBLE SHOWER
CONTROLS
" m ax
DRAIN PIPES SHALL BE
INSULATED OR PROTECTED
AGAINST CONTACT. THERE
SHALL NOT BE SHARP OR
ABRASIVE SURFACES UNDER
LAVATORIES AND SINKS.
EQUIPMENT PERMITTED
IN SHADED AREA
9" min
8" min
" m in
11" min
TOP OF
RIM OR
COUNTER
WALL MOUNT
NEW ROLL-IN SHOWER
ENCLOSURE. PROVIDE GRAB
BARS AND ACCESSIBLE SHOWER
CONTROLS
3'
0"
Revisions:
Copyright PRIME AE Group, Inc.
C
Sheet Issue Date:
APPROVALS CONSTRUCTION DOCUMENT
DIVISION OF REHABILITATION SERVICES
WORKFORCE TECHNOLOGY CENTER
REHABILITATION TECHNOLOGY SERVICES
2301 ARGONNE DRIVE, BALTIMORE MD 21218
PAM POST, SUPERVISOR - TEL. 443-236-7625
OWNER
OWNER
5/
/2
2:
:0
PM
A-101 250877
FIRST FLOOR PLAN
P in e Bo ul ev ar d
Lu sb y, M
D
M
SD
E H
O M
E A
C C
ES
SI
B
IL
IT
Y
M O
D
IF
IC
A
TI
O
N P
LA
N
B
. J O
N
ES
Project Status
Issue Date
03/31/22
R es ea rc h Pa rk D riv e
Su ite
B al tim or e, M
D
SCALE: 1/2" = 1'-0"A-101
1 DEMOLITION PLAN
SCALE: 1/2" = 1'-0"A-101
2 NEW WORK PLAN
SCALE: 1/2" = 1'-0"A-101
3 Elevation 1 - a
REMOVE EXISTING BATHTUB, FIXTURES, AND WALL SURROUND.
PREPARE FOR INSTALLATION OF NEW ROLL-IN SHOWER AND
FLOOR FINISHES
REMOVE EXISTING SINK
AND VANITY - PIPING TO
REMAIN
EXISTING TOILET TO
REMAIN
INSTALL NEW ROLL-IN SHOWER AND NEW FLOOR TILE
AS REQUIRED BY BATHTUB DEMOLITION. PROVIDE
NEW ACCESSIBLE SHOWER FIXTURES AND GRAB
BARS.
INSTALL NEW
ACCESSIBLE SINK
AND FIXTURES
NEW GRAB BAR
BEHING EXISTING
TOILET
SCALE: 1/4" = 1'-0"A-101
5 SINK CLEARANCE
SCALE: 1/2" = 1'-0"A-101
4 Elevation 1 - b
No. Date Description
EXISTING BATHOOM - BATHTUB EXISTING BATHOOM - VANITY SINK
COORDINATE ACCESSORIES/CONTROL
MOUNTING HEIGHTS AND LOCATIONS
WITH DORS/CONSUMER
Revisions:
Copyright PRIME AE Group, Inc.
C
Sheet Issue Date:
APPROVALS CONSTRUCTION DOCUMENT
DIVISION OF REHABILITATION SERVICES
WORKFORCE TECHNOLOGY CENTER
REHABILITATION TECHNOLOGY SERVICES
2301 ARGONNE DRIVE, BALTIMORE MD 21218
PAM POST, SUPERVISOR - TEL. 443-236-7625
OWNER
OWNER
5/
/2
2:
:0
PM
A-521 250877
INTERIOR DETAILS
P in e Bo ul ev ar d
Lu sb y, M
D
M
SD
E H
O M
E A
C C
ES
SI
B
IL
IT
Y
M O
D
IF
IC
A
TI
O
N P
LA
N
B
. J O
N
ES
Project Status
Issue Date
03/31/22
R es ea rc h Pa rk D riv e
Su ite
B al tim or e, M
D
REMOVE EXISTING THRESHOLD - REPLACE
WITH ADA COMPLIANT THRESHOLD
REMOVE EXISTING THRESHOLD - REPLACE
WITH ADA COMPLIANT THRESHOLD
REPLACE EXISTING KNOB HARDWARE WITH
ADA COMPLIANT LEVER HARDWARE.
PROVIDE AUTOMATIC DOOR OPENER WITH
REMOTE ACTIVATION CONTROLS
REMOVE EXISTING THRESHOLD - INSTALL
TRANSITION STRIP SCHLUTER RENO-T
REMOVE EXISTING THRESHOLD - INSTALL
TRANSITION STRIP SCHLUTER RENO-T
REMOVE EXISTING THRESHOLD - INSTALL
TRANSITION STRIP SCHLUTER RENO-T
REPLACE EXISTING KNOB HARDWARE WITH
ADA COMPLIANT LEVER HARDWARE
MAIN ENTRANCE - THRESHOLD AND DOOR HARDWARELIVING ROOM/FOYER - TRANSITIONKITCHEN/HALL - TRANSITIONBATH/HALL - TRANSITION -
DOOR HARDWARE
No. Date Description
| G-001 - TITLE SHEET |
| G-002 - ABBREVIATIONS, SYMBOLS, GENERAL NOTES, AND SHEET INDEX |
| A-101 - FIRST FLOOR PLAN |
| A-521 - INTERIOR DETAILS |
File details come from the government source that posted it. Updated .