Appendix I – Calibratable Items
Rotable Calibration Requirements
SIN Number Nomenclature Part Number Calibration Range
Required Accuracy*
Calibration Authority
Calibration Instrument Test to Accuracy Ratio Required
(TAR)
TT_MT1 thru
TT_MT13
Temperature Transducer
8230876-
4 - 20ma
(50-125ºF)
±0.1ma LDP-OCALC-12 4:1
TT_MT14 Temperature Transducer
8230876-
4 - 20ma
(30-100ºF)
±0.1ma
LDP-OCALC-12 4:1
PS_A7 AC Power Supply
4503L-3P 0 - 135 Vac
0 - 11 Aac
0 - 360 Deg
45 - 550 Hz
Note 1
± 2.0 Vac
±0.7 Aac
±2.0 Deg
±0.2 Hz
33D7-50-1987-1 4:1
3.89:1
4:1
4:1
AN_A6 Power Analyzer
New 0 - 30 Vac
0 - 208 Vac
0 - 20 AAC
0 to 1600 W
Note 1
0.3 Vac
1% RDG
0.5 Aac
1% RDG
33D7-50-1987-1 4:1
4:1
3.85:1
4:1
Note 1: Each measurement is done on all three phases.
Calibration Information Using Calibration Cart
Tag Number Nomenclature
Range
Required Accuracy*
Calibration Instrument Test to Accuracy Ratio Required
(TAR)
Suggested Calibration Instrument*
Calibration Frequency
TE_MT22 thru
TE_MT24
RTD (PT 100-
385)
50 - 150°F
± 1.4° F
4:1 Calibration Cart
PN8231300-
6 months
FT_MF6_GPM Flow Meter
ANC 32
6.0 to 200 gpm
±0.5% of reading
1.67:1 Calibration Cart
PN8231300-
6 months
FT_MF14_GPM Flow Meter
ANC 32
2.632 to
90.0 gpm
±0.5% of reading
1.67:1 Calibration Cart
PN8231300-
6 months
FT_MF15_GPM Flow Meter
ANC 8-6
0.179 to
5.529 gpm
±0.5% of reading
1.67:1 Calibration Cart
PN8231300-
6 months
ST_M1B Motor Shaft Encoder
0-8000 rpm
± 4.0 rpm 4:1 Calibration Set Secondary Reference Standard, A/E48T-6
6 months
* Calibration instrument accuracy must equal or exceed the listed requirement.
*** Environmental conditions unless otherwise noted are: 73.3ºF ±9°F, <90% RH non-condensing.
**** All accuracies are calculated using the root sum squares method for all devices.
Table - Manual Calibration Information
Tag Number Nomenclature Calibration Range
Required Accuracy*
Calibration Instrument Test to Accuracy Ratio
Suggested Calibration Instrument*
Frequency
Required
(TAR)
PT_MP1 Pressure Transducer
1 - 90 psig ± 0.4 psig 4:1 Ruska 7250XI 6 months
PT_MP2 Pressure Transducer
0 - 5
5 -195 psig
±0.6 psig
±1.0 psig
4:1 Ruska 7250XI 6 months
PT_MP3 Pressure Transducer
2 - 490 psig ± 1 psig 4:1 Ruska 7250XI 6 months
PT_MP4 Pressure Transducer
2- 490 psig ± 1 psig 4:1 Ruska 7250XI 6 months
PT_MP9 Pressure Transducer
10 - 1900 psig
± 4 psig 4:1 Ruska 7250XI 6 months
PT_RP1 Pressure Transducer
2 - 400 psig ± 4 psig 4:1 Ruska 7250XI 6 months
PDT_MP13 Pressure Transducer
1 - 100 psid
100 - 250 psid
± 1.0 psid
± 1.4 psid
2.63:1
3.69:1
Ruska 7250XI 6 months
TT_MT1 thru
TT_MT13
Temperature measurement input channel
50 - 125°F
± 1.8° F 4:1 Altek 434 6 months
TT_MT14 Temperature measurement input channel
30 - 100°F
± 1.8° F 4:1 Altek 434 6 months
TE_TK2,
TE_MEC,
TE_REC
RTD
(PT 100- 385)
50 - 150°F ± 2° F
4:1 Fluke 5520A 6 months
PDT_FL3,
PDT_FL5,
PDT_FL6,
PDT_FL14,
PDT_FL15,
PDT_FL16,
PDT_FL18
Differential Pressure
2 - 50 psid ±1.0 psid 4:1 Ruska 7250XI 6 months
LT_TK2 Level Transducer
0-30inH2O @ 4ºc
±0.25 inH2O @ 4ºC
4:1 Ruska 7250XI 6 months
FT_P2 Flow Counter Channel
10 to 2000 Hz
The greater of ±0.3% of reading or ±0.05 Hz
4:1 HP 3325A or Altek 40A or Fluke 5700 or Fluke 5520
6 months
ZT_MLT_Hz MLT Frequency 1000Hz ±5Hz 4:1 HP 3325A or Altek 40A or Fluke 5700 or Fluke 5520
6 months
FT_ITA Frequency Input Channel
10 to 2000 Hz
The greater of ±0.3% of reading or ±0.05 Hz
4:1 HP 3325A or Altek 40A or Fluke 5700 or Fluke 5520
6 months
TE_Motor1 RTD 50 - 150 °F ± 5.0° F 2:1 Fluke Model
6 months
TE_Motor2 RTD 50 - 150 °F ± 5.0° F 2:1 Fluke Model
6 months
TE_Motor3 RTD 50 - 150 °F ± 5.0° F 2:1 Fluke Model
6 months
TE_MT21 Thermocouple 30 - 270 °F ± 5.0° F 2:1 Fluke Model
6 months
TE_MT20 Thermocouple 30 - 270 °F ± 5.0° F 2:1 Fluke Model
6 months
IT_ITA1,
IT_ITA2,
IT_ITA3
Loop Current Input Channel
4 - 20 ma ±0.033 mAdc
4:1 Altek 434 6 months
* Calibration instrument accuracy must equal or exceed the listed requirement.
*** Environmental conditions unless otherwise noted are: 73.3ºF ±9°F, <90% RH non-condensing.
**** All accuracies are calculated using the root sum squares method for all devices.
NOTE
The following components are not in use and not required calibration.
PT_MP5 Pressure
5 - 900 psig ± 2 psig Not in use
No Calibration
PT_MP6 Pressure
5 - 900 psig ± 2 psig Not in use
PT_MP7 Pressure
5 - 900 psig ± 2 psig Not in use
PT_MP8 Pressure
10 - 1900 psig
± 4 psig Not in use
PT_MP10 Pressure
10 - 1900 psig
± 4 psig Not in use
PDT_MP11 Pressure
-25 to +25 psid
± 0.4 psid Not in use
PDT_MP12 Pressure
0 - 25 psid
± 0.2 psid Not in use
PDT_MP14 Pressure
1- 250 psid ± 1.4 psid Not in use
PDT_MP15 Pressure
1- 300 psid ± 1.6 psid Not in use
PDT_MP16 Pressure
2 - 400 psid
± 2.0 psid Not in use
PT_MP17 Pressure
5 - 15.0
>15.0 -
90.0 psia
± 0.15 psia
±0.20 psia
Not in
PT_MP18 Pressure
5.0 - 15.0
>15.0 - 100
>100 - 540 psia
±0.15 psia
±3.0 psia
±3.0 psia
Not in use
FT_MF1_GPM Flow Meter
ANC 10
0.5 to 15.5276 gpm
± 0.5% of reading
Not in use
FT_MF2_GPM Flow Meter
ANC 8-4
0.079 to
3.0 gpm
± 0.5% of reading
Not in use
FT_MF3_GPM Flow Meter
ANC 24
2.6 to 90.0 gpm
±0.5% of reading
Not in use
FT_MF4_GPM Flow Meter
0.16 to 0.237
>0.237 to 14.483 gpm
±9.0% of reading
±0.5% of reading
Not in use
FT_MF5_GPM Flow Meter
ANC 32
2.632 to
90.0 gpm
±0.5% of reading
Not in use
FT_MF7_GPM Flow Meter
0.16 to 0.237
>0.237 to 14.483 gpm
±9.0% of reading
±0.5% of reading
Not in use
FT_MF9_CCPM Flow Meter
JVM-12KG
20 to 50
>50 to 100
>100 to 1750 ccpm
±10% of rdg
±2% of rdg
±0.5% of rdg
Not in use
FT_MF10_GPM Flow Meter
ANC 8-6
0.179 to 5.2636 gpm
±0.5% of reading
Not in use
FT_MF11_GPM Flow Meter
ANC 8-6
0.179 to 5.2636 gpm
±0.5% of reading
Not in use
FT_MF12_GPM Flow Meter
0.079 to
3.0 gpm
±0.5% of reading
Not in use
FT_MF13_GPM Flow Meter
0.1237 to
3.0 gpm
±0.5% of reading
Not in use
FT_MF16_GPM Flow Meter
ANC 16
1.0264 to
60.0 gpm
±0.5% of reading
Not in use
WT_MTORQ Torque 0 - 120 in-lbs
±3.00 in-lbs
Not in
120 - 1200 in-lbs
±2.00% of rdg
ET_RSLVR Resolver Excitation Voltage
3 - 5 VRMS
± 0.2
VRMS
Not in use
Not in use
No Calibration Required
ET_RSLVR_Hz Resolver Excitation Frequency
2.949 kHz ± 5 Hz
ZT_MA1 thru
ZT_MA3
Resolver Angle Channel
0.2- 359.8 Deg R
± 0.15 Deg R
Not in use
ZT_MA1_Fast Resolver Angle Channel Fast Input
0.2- 359.8 Deg R
± 1.0 Deg R Not in use
IT_MI1 thru
IT_MI3
DC Current -80 - +80 mADC
± 0.1 mAdc Not in use
IT_MI1_Fast DC Current Channel Fast Input
-80 - +80 mADC
± 0.5 mAdc Not in use
ET_MLT1a and ET_MLT2a
Linear Travel Reference Voltage
0 - 10 Vdc ±0.004 Vdc Not in use
ET_MLT1b and ET_MLT2b
Linear Travel Wiper Voltage
0 - 10 Vdc ±0.004 Vdc Not in use
PS_MV1 DC Power Supply DCS55- 55-M9A
0 - 55Vdc
0 - 3.0 Adc
± 0.5 Vdc
±0.7 Adc
Not in use
PS_MV2 DC Power Supply DCS55- 55-M9A
0 - 55Vdc
0 - 3.0 Adc
± 0.5 Vdc
±0.7 Adc
Not in use