This document is the Electrical Legend and supporting construction drawings for the CAVEA Lighting Upgrade project at Metro State University in Denver, Colorado. The project encompasses lighting upgrades within the CAVEA (Center for the Arts and Events) facility located at 890 Auraria Parkway, Denver, CO 80204, and involves the installation of new LED luminaires, lighting control systems, dimming panels, and related electrical infrastructure. The scope of work includes disconnection and removal of existing fluorescent luminaires, installation of tunable white LED fixtures with various mounting configurations (recessed, surface-mounted, and track-mounted), implementation of a low-voltage dimming control system with scene programming capabilities, and associated conduit and wiring modifications. The project is designed to comply with the 2024 International Building Code, 2023 National Electrical Code, and Denver Building and Fire Codes, with the building fully sprinklered and subject to Denver Fire Authority oversight. The construction documents are dated July 17, 2026, and marked as 100% Construction Documents in Response to Comments phase.
The electrical design requires coordination of all outages with the owner's representative at least two weeks prior to work, with detailed Method of Procedure submissions required four weeks in advance and all work performed during off-hours. The project specifies branch circuits using #12 AWG conductors protected by 20-ampere circuit breakers, with provisions for larger conductors to account for voltage drop on circuits exceeding specified distances. The lighting control system utilizes an ETC Unison DRd12-24-120 dimmer panel with 24 circuits fed from existing panel L4B3, incorporating 0-10V dimming, DMX addressing for track lighting, and reverse-phase dimming relays for emergency luminaire switching. Luminaire selections include pinhole recessed downlights, wall wash fixtures with remote drivers, linear slot fixtures with adjustable downlights, and WAC Ventrix track systems with tunable white LED sources. The total connected load is 2.3 kilowatts with a calculated demand load of 2.4 kilovoltamperes, requiring 8 amperes minimum panel capacity.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
− SPECIAL SYSTEMS DEVICES −
− GRAPHIC SYMBOLS −
− EQUIPMENT −
SWITCH SYMBOL (#)
SINGLE POLE (IF BLANK)
2 = DOUBLE POLE
3 = THREE-WAY
4 = FOUR-WAY
AS = ADJUSTABLE SPEED
D = DIMMER
K = KEY OPERATED
LV = LOW VOLTAGE
M = MANUAL MOTOR SWITCH
OS = OCCUPANCY SENSOR
P = WITH PILOT LIGHT
T = TIMER
TO = THERMAL OVERLOAD
VS = VACANCY SENSOR
WP = WEATHERPROOF
x = SMALL LETTER - LUMINAIRES CONTROLLED
XP = EXPLOSION PROOF
PUSH BUTTON
A = ABORT
DA = DURESS ALARM
EPO = EMERGENCY POWER OFF
IC = INTERCOM
ST = SHUNT TRIP
LIGHTNING ARRESTOR
KEY INTERLOCK
PROTECTIVE RELAY DEVICE
RESISTOR
LOAD-BREAK CONNECTOR
POTENTIAL TRANSFORMER
CURRENT TRANSFORMER
METERING DEVICE
SPECIAL SYSTEMS SYMBOLS:
AB = ABORT BUTTON
AMP = AMPLIFIER
ANN = ANNUNCIATOR
ASD = ADJUSTABLE SPEED DRIVE
ATS = AUTOMATIC TRANSFER SWITCH
B = BUZZER
BMS = BALANCED MAGNETIC STRIP
CAM = CONTROL ADDRESSABLE MODULE
CH = CHIME
CK = CARD READER/KEYPAD
CR = CARD READER
DA = DURESS ALARM PUSH-BUTTON
DC = DOOR CONTACT
DE = DELAYED EGRESS
DMA = DOOR MANAGEMENT ALARM
DO = DOOR OPERATOR
DS = DOOR STRIKE
DTC = DATA TERMINAL CABINET
DVR = DIGITAL VIDEO RECORDER
EC = ELECTRICAL CONTACTOR
EL = ELECTRIC LOCK
ES = ELECTRIC STRIKE
F = MANUAL PULL STATION
FAA = FIRE ALARM ANNUNCIATOR
FACP = FIRE ALARM CONTROL PANEL
FS = FLOW SWITCH
FSD = FIRE SMOKE DAMPER
GB = GLASSBREAK DETECTOR
HC = HANDICAP PUSH-BUTTON
IC = INTERCOM CALL STATION
IP = INDICATOR PANEL
KP = KEYPAD
MAM = MONITOR ADDRESSABLE MODULE
MH = MANHOLE
MD = MOTORIZED DAMPER
MS = MOTION SENSOR
ML = MAGNETIC LOCK
NCMS = NURSE CALL MASTER STATION
CM-CENTRALIZED PHYSIOLOGICAL
MONITORING STATION
NCT = NURSE CALL TERMINAL CABINET
OS = OCCUPANCY SENSOR
PA = PUBLIC ADDRESS
PB = PULLBOX
PIR = PASSIVE INFRARED DETECTOR
PM = POWER QUALITY METER
PS = PRESSURE SWITCH
R = REMOTE INDICATING LIGHT
RT = REMOTE TEST STATION
RX = REQUEST TO EXIT PUSH-BUTTON
S = WALL MOUNTED SPEAKER
SAP = SECURITY ALARM PANEL
SPD = SURGE PROTECTIVE DEVICE
TC = TIME CLOCK
TS = TAMPER SWITCH
VFD = VARIABLE FREQUENCY DRIVE
VM = VIDEO MONITOR
VS = VACANCY SENSOR
ATS-XX
XXX A
TX-XXXX
DETECTOR UNDER FLOOR
F = FLAME
I = IONIZATION TYPE
P = PHOTOELECTRIC TYPE
T = THERMAL TYPE
DTB
− FIRE ALARM DEVICES −
− LIGHTING −− POWER −− GENERAL −− ONE LINE SYMBOLS −
ELECTRICAL LEGEND
− NURSE CALL −
FIRE RATED POKE-THROUGH
PARTITION CIRCUIT SPLIT
POWER POLE
SURFACE RACEWAY
FIRE HORN
WEATHERHEAD
DELUGE VALVE
THERMOSTAT
DUCT SMOKE DETECTOR
FIRE ALARM STROBE LIGHT
COMBINATION FIRE HORN/STROBE LIGHT
PULL STATION/TELEPHONE JACK
MAGNETIC DOOR HOLD OPEN
FIRE FIGHTER'S TELEPHONE JACK
TELEPHONE TERMINAL BOARD
FLOOR MOUNTED TELEPHONE OUTLET
FLOOR MOUNTED TELEPHONE/DATA OUTLET
FLOOR MOUNTED DATA OUTLET
TELEVISION JACK
WALL MOUNTED BATTERY PACK EMERGENCY LIGHT
COMBINATION TELEPHONE/DATA OUTLET
SHADING INDICATES LUMINAIRE ON LIFE SAFETY
DATA OUTLET
TELEPHONE OUTLET
PENDANT LUMINAIRE
ADJUSTABLE LUMINAIRE
TRACK LIGHTING
COMBINATION SWITCH AND RECEPTACLE
FLOOR MOUNTED JUNCTION BOX
WALL MOUNTED JUNCTION BOX
JUNCTION BOX
COMBINATION MOTOR STARTER
BRANCH CIRCUIT HOME RUN TO PANELBOARD,
DESIGNATION INDICATES PANEL AND CIRCUIT NUMBERS
STRIP LIGHT
DOWNLIGHT LUMINAIRE
WALL MOUNTED LUMINAIRE
WALL WASHER LUMINAIRE
CONDUIT STUB DOWN (OUT OF DRAWING LIMITS)
CONDUIT STUB UP (OUT OF DRAWING LIMITS)
CONDUIT BREAK SYMBOL
LIGHTING, ONE-LINE, AND POWER CIRCUITING
CONDUIT CAP
CONDUIT SEAL OFF
CEILING MOUNTED FOURPLEX RECEPTACLE
FLOOR MOUNTED SPECIAL PURPOSE RECEPTACLE
CEILING MOUNTED DUPLEX RECEPTACLE
DISCONNECT SWITCH
MOTOR STARTER
FUSED DISCONNECT SWITCH
SINGLE RECEPTACLE
SPECIAL PURPOSE RECEPTACLE
RANGE RECEPTACLE
FOURPLEX RECEPTACLE
BELL
FLOOR MOUNTED DUPLEX RECEPTACLE
FLOOR MOUNTED FOURPLEX RECEPTACLE
DATA TERMINAL BOARD
FUSE WITH SWITCH
CLOCK RECEPTACLE OUTLET
PHOTOCELL
MOTOR
CIRCUIT BREAKER
MULTIPLE BATTERIES
CONTROL FUSE
TRANSFORMER
AUTOMATIC TRANSFER SWITCH
PANELBOARD
FIRE ALARM STROBE, CEILING MOUNT
ENCLOSED BUSWAY
CONDUIT CHANGE IN ELEVATION
DUPLEX RECEPTACLE
D = DEDICATED CIRCUIT
IG = ISOLATED GROUND DEVICE
= AUTOMATICALLY CONTROLLED RECEPTACLE
X
SPEAKER
V = WITH INTEGRAL VOLUME CONTROL
LIGHTING, ONE-LINE, AND POWER CIRCUITING
(UNDERGROUND)
WALL MOUNTED EXIT LIGHT (WITH FACES AND
DIRECTION ARROWS INDICATED)
SHADING INDICATES PORTION OF LUMINAIRE
ON LIFE SAFETY
ENGINE GENERATOR
AUTOMATIC TRANSFER SWITCH WITH BY-PASS
GROUNDED WYE CONNECTION
GROUNDED WYE CONNECTION WITH RESISTOR GROUND
GROUNDED WYE CONNECTION WITH REACTOR GROUND
WYE CONNECTION
DELTA CONNECTION
DRAW-OUT POWER CIRCUIT BREAKER
GROUND BUS
CONTROL WIRING
FEEDER DESIGNATION, SEE FEEDER SCHEDULE
SECURITY CAMERA
MICROPHONE OUTLET
WALL MOUNTED SPEAKER
CONTACT NORMALLY CLOSED
CONTACT NORMALLY OPEN
EXIT LIGHT (WITH FACES AND DIRECTION ARROWS
INDICATED)
BEAM DETECTOR
SWITCH
THERMAL ELEMENT, OVERLOAD RELAY
SINGLE BATTERY
DUAL SWITCH
INTERCOM SWITCH
COMBINATION FIRE SPEAKER/STROBE LIGHT
METER
CEILING MOUNTED SPECIAL PURPOSE RECEPTACLE
DUAL PROJECTION FIRE HORN
SWITCHED RECEPTACLE
WALL MOUNTED VOLUME CONTROL
DUPLEX EMERGENCY/CRITICAL
FOURPLEX EMERGENCY/CRITICAL
STRIP LIGHT WITH LIFE SAFETY
CEILING MOUNTED TELEPHONE OUTLET
CEILING MOUNTED TELEPHONE/DATA OUTLET
CEILING MOUNTED DATA OUTLET
ENCLOSED CIRCUIT BREAKER
FLEXIBLE CONDUIT
LUMINAIRES
X = FIXTURE DESIGNATION
# = BRANCH CIRCUIT NUMBER
* = SWITCH LEG IDENTIFIER
X *
DUPLEX-2PORT USB
4PORT USB
CAPACITOR
SYMBOL DESCRIPTION
(REFER TO LUMINAIRE SCHEDULE)
DESCRIPTIONSYMBOL
(NOTE: NOT ALL SYMBOLS SHOWN ARE USED ON THESE DRAWINGS)
SYMBOL DESCRIPTION
NORTH ARROW
ROOM NUMBER
DETAIL NOTE
REVISION NUMBER
KEY NOTE
X = DENOTES ALL LUMINAIRES IN THE
RESPECTIVE AREA ARE THE TYPE INDICATED,
REFER TO LUMINAIRE SCHEDULE
DETAIL BUBBLE
DETAIL NUMBER
SECTION CUT
SHADING INDICATES EQUIPMENT
HATCHING INDICATES ITEM(S) TO BE REMOVED
SHEET NUMBER - WHERE
DETAIL IS SHOWN
MECHANICAL EQUIPMENT TAG
LIGHTING CONTROL SEQUENCE INDICATION,
SEE LIGHTING CONTROL SEQUENCE OF OPERATION
SCHEDULE FOR INFORMATION
X = DENOTES ILLUMINATION SET POINT
SECTION NUMBER/LETTER
SHEET NUMBER - WHERE
SECTION IS SHOWN
SYMBOL DESCRIPTIONSYMBOL DESCRIPTION
POLE MOUNTED LUMINAIRE
(QUANTITY OF LUMINAIRES PER
POLE AS INDICATED ON PLANS)
NEW PANEL, FLUSH MOUNTED
NEW PANEL, SURFACE MOUNTED
DISTRIBUTION PANEL
EXISTING PANEL, FLUSH MOUNTED
EXISTING PANEL, SURFACE
EXISTING DISTRIBUTION PANEL
TRANSFORMER
DRAW-OUT CIRCUIT BREAKER
(MOLDED INSULATED CASE)
DETECTOR /
FIRE ALARM STROBE/SPEAKER, CEILING MOUNT
SINGLE PATIENT STATION
STAFF ASSIST STATION
DUTY STATION
STAFF STATION
BED MANAGEMENT STATION
PATIENT MONITOR
CODE BLUE STATION
CODE PINK STATION
EMERGENCY CALL PULL STATION
AUXILIARY INPUT STATION
BED INTERFACE STATION
TWO BUTTON STATION
DOME LIGHT
ZONE LIGHT INTERSECTION
REMOTE LOCATOR
MANUAL PULL STATION
OWNER EQUIPMENT TAG
PANEL FLAG
GFI = GROUND FAULT CIRCUIT INTERRUPTER
TTB
W
M
M
S
S
V
C
T
J
J
J
X
SS
B
X
X
TAG
APPLICABLE CODES
AHJ:
YEAR CODE
IS THE BUILDING FULLY
SPRINKLERED?
Yes
No
FIRE AUTHORITY:
REMODEL NEW
2024 INTERNATIONAL BUILDING CODE
INTERNATIONAL MECHANICAL CODE
INTERNATIONAL PLUMBING CODE
INTERNATIONAL ENERGY CONSERVATION CODE
INTERNATIONAL FIRE CODE
NATIONAL ELECTRICAL CODE
2025 DENVER BUILDING AND FIRE CODES
STATE OF COLORADO
DENVER FIRE
X
X
E2.2
− GROUNDING SYMBOLS −
ELECTRICAL GROUND
GROUND ROD WITH INSPECTION TEST WELL
LIGHTNING PROTECTION AIR TERMINAL
BONDING POINT
GROUND TEST WELL
GROUNDING CONDUCTOR
GROUND BAR
GROUND ROD
PIGTAIL
G
E2.1
PANEL
XXX
X S#
B
D D
H
S
S
H
H
F
D F
P
T
XX
CB
PM
K
X
RL
D
Z
X
S
GFI
CP
EP
SP
SA
AI
DS
SS
BI
2B
BM
A100
M
E
100A4G
2400V, 100A
10SEC.
RESISTOR
TAG
TAG
(E) EXISTING
(N) NEW
(PART) PARTIAL CIRCUIT
A AMP
AC ABOVE COUNTER TOP
AF AMP FRAME, AMP FUSE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING
JURISDICTION
AIC AMPS INTERRUPTING
CAPACITY
AL ALUMINUM
APL APPLIANCE
AS AMP SWITCH
AT AMP TRIP
ATS AUTOMATIC TRANSFER
SWITCH
AV AUDIOVISUAL
BJ BONDING JUMPER
C CONDUIT
CB CIRCUIT BREAKER
CCT CIRCUIT
CCTV CLOSED CIRCUIT TV
CLG CEILING
CU COPPER
DISC DISCONNECT
DIST DISTRIBUTION
E/G ENGINE/GENERATOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR ELEVATION
EM EMERGENCY
EQPT EQUIPMENT
F FUSE
FA FIRE ALARM
FAA FIRE ALARM ANNUNCIATOR
FACP FIRE ALARM CONTROL PANEL
FIXT FIXTURE
FO FIBER OPTIC
FLR FLOOR
FLUOR FLUORESCENT
G GROUND (EQUIPMENT)
GEN GENERATOR
GFI GROUND FAULT CIRCUIT
INTERRUPTER
GF GROUND FAULT PROTECTION
GND GROUND
HC HANDICAPPED
HG HOSPITAL GRADE
HP HORSEPOWER
HV HIGH VOLTAGE
INC INCANDESCENT
− ABBREVIATIONS −
IDF INTERMEDIATE DISTRIBUTION
FRAME
IG ISOLATED GROUND
JB JUNCTION BOX
LED LIGHT EMITTING DIODE
LTG LIGHTING
LV LOW VOLTAGE
MATV MASTER ANTENNA T.V.
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDF MAIN DISTRIBUTION FRAME
MH MANHOLE
MLO MAIN LUGS ONLY
MOP METHOD OF PROCEDURE
MTD MOUNTED
MTG MOUNTING
MTR MOTOR
MV MEDIUM VOLTAGE
N NEUTRAL
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NF NON-FUSED
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
OHE OVERHEAD ELECTRIC
P POLE
PA PUBLIC ADDRESS
PB PULL BOX
PH PHASE
PNL PANEL
PWR POWER
RCPT RECEPTACLE
SBC STRANDED BARE COPPER
SPD SURGE PROTECTIVE DEVICE
SW SWITCH
TEL TELEPHONE
TP TAMPERPROOF
TV TELEVISION
UF UNDERFLOOR
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SUPPLY
V VOLTAGE
VFD VARIABLE FREQUENCY DRIVE
VP VAPOR PROOF
W WIRE
WAP WIRELESS ACCESS POINT
WG WIRE GUARD
WP WEATHERPROOF
XFMR TRANSFORMER
XP EXPLOSION PROOF
GENERAL PROJECT NOTES
1. LIGHT LINE WEIGHT INDICATES EXISTING. HEAVY LINE WEIGHT INDICATES NEW CONSTRUCTION.
2. SPECIFICATIONS ARE A PART OF THE CONSTRUCTION DOCUMENTS. SHOULD ANY CONFLICT ARISE BETWEEN THE DRAWINGS AND SPECIFICATIONS, BRING SUCH CONFLICT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. UNLESS OTHERWISE
DIRECTED BY ENGINEER, THE MOST STRINGENT REQUIREMENT WILL PREVAIL.
3. DATA ON THE DRAWINGS IS AS EXACT AS COULD BE REASONABLY SECURED. ABSOLUTE ACCURACY IS NOT GUARANTEED. VERIFY EXACT LOCATIONS, MEASUREMENTS, LEVELS, SPACE REQUIREMENTS, POTENTIAL CONFLICTS WITH OTHER TRADES. ADAPT WORK TO ACTUAL CONDITIONS AT THE SITE. VISIT THE SITE TO BECOME THOROUGHLY FAMILIAR WITH THE ACTUAL CONDITIONS OF THIS PROJECT BEFORE SUBMITTING COSTS. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE;
DO NOT SCALE. THESE DRAWINGS DO NOT SHOW MATERIALS FOR A COMPLETE INSTALLATION; PLAN THE INSTALLATION AND LAYOUT OF THE WORK AS DIAGRAMMED IN THESE DOCUMENTS. REFER TO FLOOR PLANS, SCHEMATICS AND DIAGRAMS OF OTHER TRADES FOR ELECTRICAL REQUIREMENTS, BRANCH CIRCUITS AND OTHER ELECTRICAL CONNECTIONS NOT INDICATED
ON THESE DOCUMENTS.
4. FIRE-SEAL ALL PENETRATIONS THROUGH RATED ASSEMBLIES WITH MATERIALS CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR FIRE STOPS ASTM E814.
5. JUNCTION BOXES FOR LUMINAIRES AND OUTLETS ARE NOT INDICATED. PROVIDE THE PROPER QUANTITY OF JUNCTION BOXES
TO MEET LOCAL CODE AND NATIONAL ELECTRICAL CODE.
6. EXECUTE THE WORK IN ACCORDANCE WITH SUPPORTING OBJECTS FOR SEISMIC ZONE REQUIRED BY STATE AND LOCAL CODES FOR ALL CEILING ATTACHED OBJECTS AND FLOOR ATTACHED EQUIPMENT INCLUDING, BUT NOT LIMITED TO: PENDANT LIGHTING FIXTURES, GENERAL LIGHTING, MULTIPLE RACEWAYS, GENERATOR, TRANSFORMER, ELECTRICAL SWITCHGEAR, SWITCHBOARDS AND OTHER ELECTRICAL EQUIPMENT.
7. COORDINATE AND SCHEDULE ALL ELECTRICAL OUTAGES AND OUTAGE TIME FRAMES WITH OWNER’S REPRESENTATIVE AT LEAST TWO WEEKS PRIOR TO OUTAGE. ACCOMPLISH ALL PREP WORK PRIOR TO OUTAGE TO MINIMIZE THE OUTAGE TIME FRAME. SUBMIT A DETAILED METHOD OF PROCEDURE (MOP) FOR ALL OUTAGES FOUR WEEKS PRIOR TO OUTAGE. PERFORM
OUTAGES DURING OFF HOURS AT A TIME ACCEPTABLE BY THE OWNER.
8. UPDATE PANEL SCHEDULES TO REFLECT INSTALLED CONDITIONS AFTER CONSTRUCTION IS COMPLETE.
9. UNLESS OTHERWISE INDICATED, BRANCH CIRCUITS SHALL BE 3/4"C (2#12, #12G) PROTECTED BY 20-AMPERE CIRCUIT BREAKERS.
INCREASE CONDUCTOR SIZE TO ACCOUNT FOR VOLTAGE DROP FOR ALL 120-VOLT CIRCUITS OVER 75 FEET, AND ALL 277-VOLT CIRCUITS OVER 150 FEET TO THE FIRST OUTLET. CONDUCTOR SIZE SHALL BE UNIFORM FOR THE ENTIRE LENGTH OF THE CIRCUIT UNLESS NOTED OTHERWISE. HOMERUNS WHICH INDICATE UPGRADING CIRCUIT CONDUCTORS FOR VOLTAGE DROP, E.G., #10AWG WIRE ON 20-AMPERE CIRCUIT, SHALL HAVE THE CONDUCTOR SIZE INDICATED CARRIED THROUGHOUT THE CIRCUIT TO ALL JUNCTION BOXES UP TO AND INCLUDING THE J-BOX NEAREST THE LAST DEVICE OR LUMINAIRE.
10. THESE DRAWINGS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY OTHERS. DATA PRESENTED ON THIS DRAWING IS AS ACCURATE AS CAN BE DETERMINED, BUT ACCURACY IS NOT GUARANTEED. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ENGINEER IS NEITHER RESPONSIBLE FOR ITS ACCURACY, NOR ERRORS NOR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DOCUMENTS. FIELD VERIFICATION OF ALL AFFECTED COMPONENTS IS
REQUIRED.
11. PATCH AND PAINT ANY DAMAGED SURFACES DUE TO DEMOLITION AND CONSTRUCTION TO MATCH EXISTING CONDITIONS. SEAL ALL PENETRATIONS THROUGH RATED CEILINGS AND WALLS WITH UL LISTED SEALANTS AND FIRESTOPPING MATERIALS.
12. UP-TO-DATE ELECTRICAL RECORD DRAWINGS ARE NOT AVAILABLE FOR THIS PROJECT. INFORMATION FOR EXISTING CIRCUITRY IS BASED ON EXISTING PANEL DIRECTORIES, AVAILABLE DRAWINGS, AND ASSUMPTIONS. LOCATIONS AND INFORMATION FOR EXISTING ELECTRICAL DEVICES AND EQUIPMENT SHOWN ON THESE DOCUMENTS ARE APPROXIMATE AND WERE DERIVED FROM FIELD OBSERVATION AND AVAILABLE RECORD DRAWINGS. VERIFY ACTUAL FIELD CONDITIONS PRIOR TO STARTING WORK.
DEMOLITION PROJECT NOTES
1. WORK SHOWN HATCHED IS EXISTING TO BE REMOVED. REMOVE ALL DEVICES ON WALLS WHICH ARE REMOVED. WHERE DEVICES ARE REMOVED, REMOVE ASSOCIATED CIRCUIT CONDUCTORS AND CONDUIT BACK TO THE SERVING PANELBOARD OR
NEXT DEVICE ON THE CIRCUIT WHICH REMAINS (MAINTAIN CIRCUIT CONTINUITY).
2. UNLESS OTHERWISE INDICATED, DEMOLITION WASTE BECOMES PROPERTY OF CONTRACTOR. REMOVE DEMOLITION WASTE MATERIALS FROM PROJECT SITE AND DISPOSE OF THEM IN AN APPROVED CONSTRUCTION AND DEMOLITION WASTE LANDFILL ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. COORDINATE DISPOSAL LOCATION WITH OWNERS REPRESENTATIVE
PRIOR TO DISPOSING OF ANY REMOVED ELECTRICAL EQUIPMENT.
3. EXISTING CIRCUIT INFORMATION SHOWN ON THE PLANS IS FOR REFERENCE ONLY. TRACE ALL EXISTING CIRCUITS AFFECTED
BY THIS WORK TO CONFIRM SOURCE PANEL AND CIRCUIT NUMBERS.
4. INFORMATION ON THE DRAWINGS HAS BEEN TAKEN FROM RECORD DRAWINGS. DEMOLITION DRAWINGS ARE INTENDED TO GIVE A COMMON BASIS FOR WORK. VISIT THE SITE, PRIOR TO FINAL PRICING AND BECOME FAMILIAR WITH THE EXTENT OF WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE
END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS.
5. MAINTAIN FIRE ALARM SYSTEM OPERATION IN ALL AREAS OUTSIDE OF THE AREA OF WORK DURING CONSTRUCTION.
LIGHTING PROJECT NOTES
1. EXISTING CIRCUIT INFORMATION SHOWN ON THE PLANS IS FOR REFERENCE ONLY. TRACE ALL EXISTING CIRCUITS AFFECTED
BY THIS WORK TO CONFIRM SOURCE PANEL AND CIRCUIT NUMBERS.
2. UPPERCASE LETTER DENOTES LUMINAIRE TYPE. LOWERCASE LETTER INDICATES CONTROL ZONE.
3. EMERGENCY LUMINAIRES SHALL BE SWITCHED WITH THE REST OF THE LUMINAIRES IN THE ROOM OR AS INDICATED ON THE DRAWINGS BY LIGHTING CONTROL ZONE. PROVIDE ONE EMERGENCY TRANSFER RELAY PER CONTROL ZONE. RELAY SHALL BE
INSTALLED IN AN ACCESSIBLE LOCATION.
4. TO ACHIEVE THE INDICATED SEQUENCE OF OPERATION, PROVIDE ALL COMPONENTS AND DIMMING CABLING REQUIRED FOR THE LIGHTING CONTROL SYSTEM, WHETHER INDICATED OR NOT. REFER TO LIGHTING CONTROL SEQUENCE OF OPERATION
SCHEDULE FOR ADDITIONAL INFORMATION.
5. PROVIDE DIMMERS COMPATIBLE WITH LED DRIVERS AND POWER SUPPLIES PER MANUFACTURER'S RECOMMENDATIONS.
PROVIDE COMPONENTS AND ACCESSORIES TO ACCOMPLISH COMPLETE DIMMING FUNCTIONALITY AS SHOWN ON PLANS AND
NOTED IN THE LUMINAIRE SCHEDULE.
6. FOR LIGHT DIMMING BRANCH CIRCUITS, PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT CURRENT CARRYING CONDUCTOR. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX CURRENT CARRYING CONDUCTORS WITH PROPER DE-RATING AS REQUIRED BY NEC. PROVIDE FULL LENGTH STRIPING FOR DEDICATED NEUTRALS TO MATCH
ASSOCIATED CURRENT CARRYING CONDUCTOR COLOR.
7. LIGHTING CONTROLS COMMISSIONING SHALL COMPLY WITH IECC 2024, INCLUDING BUT NOT LIMITED TO COMMISSIONING DOCUMENTS, SYSTEM FUNCTIONAL TESTING, AND RECORD DOCUMENTS. REFER TO SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
COPYRIGHT, THE RMH GROUP, INC. 2025REV: 10/21/2024
m a k in g a d if fe re n c e t h ro u g h e n g in e e ri n g
W e st
C o lfa x A ve
L a ke w o o d
C O
P h o e
-2
-0
D e n ve r
P h o e n ix
L o s
A n g e le s w w w .r m h g ro u p .c o m
M e c h a n ic a l
E le c tr ic a l In d u s tr ia l
S u s ta in a b il it y
S M
D a te
S c a le
D e s ig n e d B y
D ra w n B y
A p p ro v e d B y
P ro je c t
N o
P ro je c t
S ta tu s
SHT NO: REVISION
N o n e
/2
/2
:4
:1
P
M
C U s e rs \m b ru m a g e
\D o c u m e n ts
\2
-M
E T
R O
C A
V E
A L
IG
H
T
IN
G
M E
P m b ru m a g e .r v t
E-001
E L E
C T
R
IC
A L L
E G
E N
D
M E
T R
O S
T A
T E
U N
IV
E
R S
IT
Y
C A
V E
A L
IG
H
T
IN
G U
P G
R A
D E
J U
L Y
S R
J
M L B
S K
B
C D
R M
H -2
R E
V D
A T
E D
E S
C R
IP
T
IO
N
/2
/2
R
E S
P O
N S
E T
O C
O M
M E
N T
S
09.21.2026
/1
/2
:4
:2
A
M
C U s e rs \m b ru m a g e
\D o c u m e n ts
\2
-M
E T
R O
C A
V E
A L
IG
H
T
IN
G
M E
P m b ru m a g e .r v t
METRO STATE UNIVERSITY
CAVEA LIGHTING UPGRADE
JULY 17, 2026
100% CONSTRUCTION DOCUMENTS
PROJECT LOCATION: 890 AURARIA PKWY, DENVER, CO 80204
PRIME CONSULTANT
MECHANICAL, ELECTRICAL, AND PLUMBING
ENGINEERING
(SITE MAP)
making a difference through engineering
SM
AREA OF WORK
OWNER
E-602 LIGHTING COMCHECK
E-601 ELECTRICAL SCHEDULES
E-114 PARTIAL LIGHTING PLAN LEVEL 4
E-002 ELECTRICAL ONE-LINE DIAGRAM
E-001 ELECTRICAL LEGEND
ELECTRICAL
G-000 PROJECT COVER SHEET
GENERAL
PROJECT MANAGER / ELECTRICAL ENGINEER:
SHARA JOHNSON
SJOHNSON@RMHGROUP.COM
303-239-2727
PROJECT MANAGER:
DANIELLE PRUETTE
DPRUETTE@WEMBERINC.COM
303-518-8181
ASSISTANT DIRECTOR OF EVENT DESIGN:
TOBY HATCHER
THATCHE2@MSUDENVER.EDU
703-853-3994
07.17.2026
− SPECIAL SYSTEMS DEVICES −
− GRAPHIC SYMBOLS −
− EQUIPMENT −
SWITCH SYMBOL (#)
SINGLE POLE (IF BLANK)
2 = DOUBLE POLE
3 = THREE-WAY
4 = FOUR-WAY
AS = ADJUSTABLE SPEED
D = DIMMER
K = KEY OPERATED
LV = LOW VOLTAGE
M = MANUAL MOTOR SWITCH
OS = OCCUPANCY SENSOR
P = WITH PILOT LIGHT
T = TIMER
TO = THERMAL OVERLOAD
VS = VACANCY SENSOR
WP = WEATHERPROOF
x = SMALL LETTER - LUMINAIRES CONTROLLED
XP = EXPLOSION PROOF
PUSH BUTTON
A = ABORT
DA = DURESS ALARM
EPO = EMERGENCY POWER OFF
IC = INTERCOM
ST = SHUNT TRIP
LIGHTNING ARRESTOR
KEY INTERLOCK
PROTECTIVE RELAY DEVICE
RESISTOR
LOAD-BREAK CONNECTOR
POTENTIAL TRANSFORMER
CURRENT TRANSFORMER
METERING DEVICE
SPECIAL SYSTEMS SYMBOLS:
AB = ABORT BUTTON
AMP = AMPLIFIER
ANN = ANNUNCIATOR
ASD = ADJUSTABLE SPEED DRIVE
ATS = AUTOMATIC TRANSFER SWITCH
B = BUZZER
BMS = BALANCED MAGNETIC STRIP
CAM = CONTROL ADDRESSABLE MODULE
CH = CHIME
CK = CARD READER/KEYPAD
CR = CARD READER
DA = DURESS ALARM PUSH-BUTTON
DC = DOOR CONTACT
DE = DELAYED EGRESS
DMA = DOOR MANAGEMENT ALARM
DO = DOOR OPERATOR
DS = DOOR STRIKE
DTC = DATA TERMINAL CABINET
DVR = DIGITAL VIDEO RECORDER
EC = ELECTRICAL CONTACTOR
EL = ELECTRIC LOCK
ES = ELECTRIC STRIKE
F = MANUAL PULL STATION
FAA = FIRE ALARM ANNUNCIATOR
FACP = FIRE ALARM CONTROL PANEL
FS = FLOW SWITCH
FSD = FIRE SMOKE DAMPER
GB = GLASSBREAK DETECTOR
HC = HANDICAP PUSH-BUTTON
IC = INTERCOM CALL STATION
IP = INDICATOR PANEL
KP = KEYPAD
MAM = MONITOR ADDRESSABLE MODULE
MH = MANHOLE
MD = MOTORIZED DAMPER
MS = MOTION SENSOR
ML = MAGNETIC LOCK
NCMS = NURSE CALL MASTER STATION
CM-CENTRALIZED PHYSIOLOGICAL
MONITORING STATION
NCT = NURSE CALL TERMINAL CABINET
OS = OCCUPANCY SENSOR
PA = PUBLIC ADDRESS
PB = PULLBOX
PIR = PASSIVE INFRARED DETECTOR
PM = POWER QUALITY METER
PS = PRESSURE SWITCH
R = REMOTE INDICATING LIGHT
RT = REMOTE TEST STATION
RX = REQUEST TO EXIT PUSH-BUTTON
S = WALL MOUNTED SPEAKER
SAP = SECURITY ALARM PANEL
SPD = SURGE PROTECTIVE DEVICE
TC = TIME CLOCK
TS = TAMPER SWITCH
VFD = VARIABLE FREQUENCY DRIVE
VM = VIDEO MONITOR
VS = VACANCY SENSOR
ATS-XX
XXX A
TX-XXXX
DETECTOR UNDER FLOOR
F = FLAME
I = IONIZATION TYPE
P = PHOTOELECTRIC TYPE
T = THERMAL TYPE
DTB
− FIRE ALARM DEVICES −
− LIGHTING −− POWER −− GENERAL −− ONE LINE SYMBOLS −
ELECTRICAL LEGEND
− NURSE CALL −
FIRE RATED POKE-THROUGH
PARTITION CIRCUIT SPLIT
POWER POLE
SURFACE RACEWAY
FIRE HORN
WEATHERHEAD
DELUGE VALVE
THERMOSTAT
DUCT SMOKE DETECTOR
FIRE ALARM STROBE LIGHT
COMBINATION FIRE HORN/STROBE LIGHT
PULL STATION/TELEPHONE JACK
MAGNETIC DOOR HOLD OPEN
FIRE FIGHTER'S TELEPHONE JACK
TELEPHONE TERMINAL BOARD
FLOOR MOUNTED TELEPHONE OUTLET
FLOOR MOUNTED TELEPHONE/DATA OUTLET
FLOOR MOUNTED DATA OUTLET
TELEVISION JACK
WALL MOUNTED BATTERY PACK EMERGENCY LIGHT
COMBINATION TELEPHONE/DATA OUTLET
SHADING INDICATES LUMINAIRE ON LIFE SAFETY
DATA OUTLET
TELEPHONE OUTLET
PENDANT LUMINAIRE
ADJUSTABLE LUMINAIRE
TRACK LIGHTING
COMBINATION SWITCH AND RECEPTACLE
FLOOR MOUNTED JUNCTION BOX
WALL MOUNTED JUNCTION BOX
JUNCTION BOX
COMBINATION MOTOR STARTER
BRANCH CIRCUIT HOME RUN TO PANELBOARD,
DESIGNATION INDICATES PANEL AND CIRCUIT NUMBERS
STRIP LIGHT
DOWNLIGHT LUMINAIRE
WALL MOUNTED LUMINAIRE
WALL WASHER LUMINAIRE
CONDUIT STUB DOWN (OUT OF DRAWING LIMITS)
CONDUIT STUB UP (OUT OF DRAWING LIMITS)
CONDUIT BREAK SYMBOL
LIGHTING, ONE-LINE, AND POWER CIRCUITING
CONDUIT CAP
CONDUIT SEAL OFF
CEILING MOUNTED FOURPLEX RECEPTACLE
FLOOR MOUNTED SPECIAL PURPOSE RECEPTACLE
CEILING MOUNTED DUPLEX RECEPTACLE
DISCONNECT SWITCH
MOTOR STARTER
FUSED DISCONNECT SWITCH
SINGLE RECEPTACLE
SPECIAL PURPOSE RECEPTACLE
RANGE RECEPTACLE
FOURPLEX RECEPTACLE
BELL
FLOOR MOUNTED DUPLEX RECEPTACLE
FLOOR MOUNTED FOURPLEX RECEPTACLE
DATA TERMINAL BOARD
FUSE WITH SWITCH
CLOCK RECEPTACLE OUTLET
PHOTOCELL
MOTOR
CIRCUIT BREAKER
MULTIPLE BATTERIES
CONTROL FUSE
TRANSFORMER
AUTOMATIC TRANSFER SWITCH
PANELBOARD
FIRE ALARM STROBE, CEILING MOUNT
ENCLOSED BUSWAY
CONDUIT CHANGE IN ELEVATION
DUPLEX RECEPTACLE
D = DEDICATED CIRCUIT
IG = ISOLATED GROUND DEVICE
= AUTOMATICALLY CONTROLLED RECEPTACLE
X
SPEAKER
V = WITH INTEGRAL VOLUME CONTROL
LIGHTING, ONE-LINE, AND POWER CIRCUITING
(UNDERGROUND)
WALL MOUNTED EXIT LIGHT (WITH FACES AND
DIRECTION ARROWS INDICATED)
SHADING INDICATES PORTION OF LUMINAIRE
ON LIFE SAFETY
ENGINE GENERATOR
AUTOMATIC TRANSFER SWITCH WITH BY-PASS
GROUNDED WYE CONNECTION
GROUNDED WYE CONNECTION WITH RESISTOR GROUND
GROUNDED WYE CONNECTION WITH REACTOR GROUND
WYE CONNECTION
DELTA CONNECTION
DRAW-OUT POWER CIRCUIT BREAKER
GROUND BUS
CONTROL WIRING
FEEDER DESIGNATION, SEE FEEDER SCHEDULE
SECURITY CAMERA
MICROPHONE OUTLET
WALL MOUNTED SPEAKER
CONTACT NORMALLY CLOSED
CONTACT NORMALLY OPEN
EXIT LIGHT (WITH FACES AND DIRECTION ARROWS
INDICATED)
BEAM DETECTOR
SWITCH
THERMAL ELEMENT, OVERLOAD RELAY
SINGLE BATTERY
DUAL SWITCH
INTERCOM SWITCH
COMBINATION FIRE SPEAKER/STROBE LIGHT
METER
CEILING MOUNTED SPECIAL PURPOSE RECEPTACLE
DUAL PROJECTION FIRE HORN
SWITCHED RECEPTACLE
WALL MOUNTED VOLUME CONTROL
DUPLEX EMERGENCY/CRITICAL
FOURPLEX EMERGENCY/CRITICAL
STRIP LIGHT WITH LIFE SAFETY
CEILING MOUNTED TELEPHONE OUTLET
CEILING MOUNTED TELEPHONE/DATA OUTLET
CEILING MOUNTED DATA OUTLET
ENCLOSED CIRCUIT BREAKER
FLEXIBLE CONDUIT
LUMINAIRES
X = FIXTURE DESIGNATION
# = BRANCH CIRCUIT NUMBER
* = SWITCH LEG IDENTIFIER
X *
DUPLEX-2PORT USB
4PORT USB
CAPACITOR
SYMBOL DESCRIPTION
(REFER TO LUMINAIRE SCHEDULE)
DESCRIPTIONSYMBOL
(NOTE: NOT ALL SYMBOLS SHOWN ARE USED ON THESE DRAWINGS)
SYMBOL DESCRIPTION
NORTH ARROW
ROOM NUMBER
DETAIL NOTE
REVISION NUMBER
KEY NOTE
X = DENOTES ALL LUMINAIRES IN THE
RESPECTIVE AREA ARE THE TYPE INDICATED,
REFER TO LUMINAIRE SCHEDULE
DETAIL BUBBLE
DETAIL NUMBER
SECTION CUT
SHADING INDICATES EQUIPMENT
HATCHING INDICATES ITEM(S) TO BE REMOVED
SHEET NUMBER - WHERE
DETAIL IS SHOWN
MECHANICAL EQUIPMENT TAG
LIGHTING CONTROL SEQUENCE INDICATION,
SEE LIGHTING CONTROL SEQUENCE OF OPERATION
SCHEDULE FOR INFORMATION
X = DENOTES ILLUMINATION SET POINT
SECTION NUMBER/LETTER
SHEET NUMBER - WHERE
SECTION IS SHOWN
SYMBOL DESCRIPTIONSYMBOL DESCRIPTION
POLE MOUNTED LUMINAIRE
(QUANTITY OF LUMINAIRES PER
POLE AS INDICATED ON PLANS)
NEW PANEL, FLUSH MOUNTED
NEW PANEL, SURFACE MOUNTED
DISTRIBUTION PANEL
EXISTING PANEL, FLUSH MOUNTED
EXISTING PANEL, SURFACE
EXISTING DISTRIBUTION PANEL
TRANSFORMER
DRAW-OUT CIRCUIT BREAKER
(MOLDED INSULATED CASE)
DETECTOR /
FIRE ALARM STROBE/SPEAKER, CEILING MOUNT
SINGLE PATIENT STATION
STAFF ASSIST STATION
DUTY STATION
STAFF STATION
BED MANAGEMENT STATION
PATIENT MONITOR
CODE BLUE STATION
CODE PINK STATION
EMERGENCY CALL PULL STATION
AUXILIARY INPUT STATION
BED INTERFACE STATION
TWO BUTTON STATION
DOME LIGHT
ZONE LIGHT INTERSECTION
REMOTE LOCATOR
MANUAL PULL STATION
OWNER EQUIPMENT TAG
PANEL FLAG
GFI = GROUND FAULT CIRCUIT INTERRUPTER
TTB
W
M
M
S
S
V
C
T
J
J
J
X
SS
B
X
X
TAG
APPLICABLE CODES
AHJ:
YEAR CODE
IS THE BUILDING FULLY
SPRINKLERED?
Yes
No
FIRE AUTHORITY:
REMODEL NEW
2024 INTERNATIONAL BUILDING CODE
INTERNATIONAL MECHANICAL CODE
INTERNATIONAL PLUMBING CODE
INTERNATIONAL ENERGY CONSERVATION CODE
INTERNATIONAL FIRE CODE
NATIONAL ELECTRICAL CODE
2025 DENVER BUILDING AND FIRE CODES
STATE OF COLORADO
DENVER FIRE
X
X
E2.2
− GROUNDING SYMBOLS −
ELECTRICAL GROUND
GROUND ROD WITH INSPECTION TEST WELL
LIGHTNING PROTECTION AIR TERMINAL
BONDING POINT
GROUND TEST WELL
GROUNDING CONDUCTOR
GROUND BAR
GROUND ROD
PIGTAIL
G
E2.1
PANEL
XXX
X S#
B
D D
H
S
S
H
H
F
D F
P
T
XX
CB
PM
K
X
RL
D
Z
X
S
GFI
CP
EP
SP
SA
AI
DS
SS
BI
2B
BM
A100
M
E
100A4G
2400V, 100A
10SEC.
RESISTOR
TAG
TAG
(E) EXISTING
(N) NEW
(PART) PARTIAL CIRCUIT
A AMP
AC ABOVE COUNTER TOP
AF AMP FRAME, AMP FUSE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING
JURISDICTION
AIC AMPS INTERRUPTING
CAPACITY
AL ALUMINUM
APL APPLIANCE
AS AMP SWITCH
AT AMP TRIP
ATS AUTOMATIC TRANSFER
SWITCH
AV AUDIOVISUAL
BJ BONDING JUMPER
C CONDUIT
CB CIRCUIT BREAKER
CCT CIRCUIT
CCTV CLOSED CIRCUIT TV
CLG CEILING
CU COPPER
DISC DISCONNECT
DIST DISTRIBUTION
E/G ENGINE/GENERATOR
ELEC ELECTRIC, ELECTRICAL
ELEV ELEVATOR ELEVATION
EM EMERGENCY
EQPT EQUIPMENT
F FUSE
FA FIRE ALARM
FAA FIRE ALARM ANNUNCIATOR
FACP FIRE ALARM CONTROL PANEL
FIXT FIXTURE
FO FIBER OPTIC
FLR FLOOR
FLUOR FLUORESCENT
G GROUND (EQUIPMENT)
GEN GENERATOR
GFI GROUND FAULT CIRCUIT
INTERRUPTER
GF GROUND FAULT PROTECTION
GND GROUND
HC HANDICAPPED
HG HOSPITAL GRADE
HP HORSEPOWER
HV HIGH VOLTAGE
INC INCANDESCENT
− ABBREVIATIONS −
IDF INTERMEDIATE DISTRIBUTION
FRAME
IG ISOLATED GROUND
JB JUNCTION BOX
LED LIGHT EMITTING DIODE
LTG LIGHTING
LV LOW VOLTAGE
MATV MASTER ANTENNA T.V.
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDF MAIN DISTRIBUTION FRAME
MH MANHOLE
MLO MAIN LUGS ONLY
MOP METHOD OF PROCEDURE
MTD MOUNTED
MTG MOUNTING
MTR MOTOR
MV MEDIUM VOLTAGE
N NEUTRAL
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NF NON-FUSED
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
OHE OVERHEAD ELECTRIC
P POLE
PA PUBLIC ADDRESS
PB PULL BOX
PH PHASE
PNL PANEL
PWR POWER
RCPT RECEPTACLE
SBC STRANDED BARE COPPER
SPD SURGE PROTECTIVE DEVICE
SW SWITCH
TEL TELEPHONE
TP TAMPERPROOF
TV TELEVISION
UF UNDERFLOOR
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SUPPLY
V VOLTAGE
VFD VARIABLE FREQUENCY DRIVE
VP VAPOR PROOF
W WIRE
WAP WIRELESS ACCESS POINT
WG WIRE GUARD
WP WEATHERPROOF
XFMR TRANSFORMER
XP EXPLOSION PROOF
GENERAL PROJECT NOTES
1. LIGHT LINE WEIGHT INDICATES EXISTING. HEAVY LINE WEIGHT INDICATES NEW CONSTRUCTION.
2. SPECIFICATIONS ARE A PART OF THE CONSTRUCTION DOCUMENTS. SHOULD ANY CONFLICT ARISE BETWEEN THE DRAWINGS AND SPECIFICATIONS, BRING SUCH CONFLICT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. UNLESS OTHERWISE
DIRECTED BY ENGINEER, THE MOST STRINGENT REQUIREMENT WILL PREVAIL.
3. DATA ON THE DRAWINGS IS AS EXACT AS COULD BE REASONABLY SECURED. ABSOLUTE ACCURACY IS NOT GUARANTEED. VERIFY EXACT LOCATIONS, MEASUREMENTS, LEVELS, SPACE REQUIREMENTS, POTENTIAL CONFLICTS WITH OTHER TRADES. ADAPT WORK TO ACTUAL CONDITIONS AT THE SITE. VISIT THE SITE TO BECOME THOROUGHLY FAMILIAR WITH THE ACTUAL CONDITIONS OF THIS PROJECT BEFORE SUBMITTING COSTS. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE;
DO NOT SCALE. THESE DRAWINGS DO NOT SHOW MATERIALS FOR A COMPLETE INSTALLATION; PLAN THE INSTALLATION AND LAYOUT OF THE WORK AS DIAGRAMMED IN THESE DOCUMENTS. REFER TO FLOOR PLANS, SCHEMATICS AND DIAGRAMS OF OTHER TRADES FOR ELECTRICAL REQUIREMENTS, BRANCH CIRCUITS AND OTHER ELECTRICAL CONNECTIONS NOT INDICATED
ON THESE DOCUMENTS.
4. FIRE-SEAL ALL PENETRATIONS THROUGH RATED ASSEMBLIES WITH MATERIALS CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR FIRE STOPS ASTM E814.
5. JUNCTION BOXES FOR LUMINAIRES AND OUTLETS ARE NOT INDICATED. PROVIDE THE PROPER QUANTITY OF JUNCTION BOXES
TO MEET LOCAL CODE AND NATIONAL ELECTRICAL CODE.
6. EXECUTE THE WORK IN ACCORDANCE WITH SUPPORTING OBJECTS FOR SEISMIC ZONE REQUIRED BY STATE AND LOCAL CODES FOR ALL CEILING ATTACHED OBJECTS AND FLOOR ATTACHED EQUIPMENT INCLUDING, BUT NOT LIMITED TO: PENDANT LIGHTING FIXTURES, GENERAL LIGHTING, MULTIPLE RACEWAYS, GENERATOR, TRANSFORMER, ELECTRICAL SWITCHGEAR, SWITCHBOARDS AND OTHER ELECTRICAL EQUIPMENT.
7. COORDINATE AND SCHEDULE ALL ELECTRICAL OUTAGES AND OUTAGE TIME FRAMES WITH OWNER’S REPRESENTATIVE AT LEAST TWO WEEKS PRIOR TO OUTAGE. ACCOMPLISH ALL PREP WORK PRIOR TO OUTAGE TO MINIMIZE THE OUTAGE TIME FRAME. SUBMIT A DETAILED METHOD OF PROCEDURE (MOP) FOR ALL OUTAGES FOUR WEEKS PRIOR TO OUTAGE. PERFORM
OUTAGES DURING OFF HOURS AT A TIME ACCEPTABLE BY THE OWNER.
8. UPDATE PANEL SCHEDULES TO REFLECT INSTALLED CONDITIONS AFTER CONSTRUCTION IS COMPLETE.
9. UNLESS OTHERWISE INDICATED, ALL CONDUCTORS FOR BRANCH CIRCUITS SHALL BE #12 AWG PROTECTED BY 20-AMPERE CIRCUIT BREAKERS. INCREASE CONDUCTOR SIZE TO ACCOUNT FOR VOLTAGE DROP FOR ALL 120-VOLT CIRCUITS OVER 75 FEET, AND ALL 277-VOLT CIRCUITS OVER 150 FEET TO THE FIRST OUTLET. CONDUCTOR SIZE SHALL BE UNIFORM FOR THE ENTIRE LENGTH OF THE CIRCUIT UNLESS NOTED OTHERWISE. HOMERUNS WHICH INDICATE UPGRADING CIRCUIT CONDUCTORS FOR VOLTAGE DROP, E.G., #10AWG WIRE ON 20-AMPERE CIRCUIT, SHALL HAVE THE CONDUCTOR SIZE INDICATED CARRIED THROUGHOUT THE CIRCUIT TO ALL JUNCTION BOXES UP TO AND INCLUDING THE J-BOX NEAREST THE LAST DEVICE OR
LUMINAIRE.
10. THESE DRAWINGS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY OTHERS. DATA PRESENTED ON THIS DRAWING IS AS ACCURATE AS CAN BE DETERMINED, BUT ACCURACY IS NOT GUARANTEED. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, THE ENGINEER IS NEITHER RESPONSIBLE FOR ITS ACCURACY, NOR ERRORS NOR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DOCUMENTS. FIELD VERIFICATION OF ALL AFFECTED COMPONENTS IS
REQUIRED.
11. PATCH AND PAINT ANY DAMAGED SURFACES DUE TO DEMOLITION AND CONSTRUCTION TO MATCH EXISTING CONDITIONS. SEAL ALL PENETRATIONS THROUGH RATED CEILINGS AND WALLS WITH UL LISTED SEALANTS AND FIRESTOPPING MATERIALS.
12. UP-TO-DATE ELECTRICAL RECORD DRAWINGS ARE NOT AVAILABLE FOR THIS PROJECT. INFORMATION FOR EXISTING CIRCUITRY IS BASED ON EXISTING PANEL DIRECTORIES, AVAILABLE DRAWINGS, AND ASSUMPTIONS. LOCATIONS AND INFORMATION FOR EXISTING ELECTRICAL DEVICES AND EQUIPMENT SHOWN ON THESE DOCUMENTS ARE APPROXIMATE AND WERE DERIVED FROM FIELD OBSERVATION AND AVAILABLE RECORD DRAWINGS. VERIFY ACTUAL FIELD CONDITIONS PRIOR TO STARTING WORK.
DEMOLITION PROJECT NOTES
1. WORK SHOWN HATCHED IS EXISTING TO BE REMOVED. REMOVE ALL DEVICES ON WALLS WHICH ARE REMOVED. WHERE
DEVICES ARE REMOVED, REMOVE ASSOCIATED CIRCUIT CONDUCTORS AND CONDUIT BACK TO THE SERVING PANELBOARD OR
NEXT DEVICE ON THE CIRCUIT WHICH REMAINS (MAINTAIN CIRCUIT CONTINUITY).
2. UNLESS OTHERWISE INDICATED, DEMOLITION WASTE BECOMES PROPERTY OF CONTRACTOR. REMOVE DEMOLITION WASTE MATERIALS FROM PROJECT SITE AND DISPOSE OF THEM IN AN APPROVED CONSTRUCTION AND DEMOLITION WASTE LANDFILL ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. COORDINATE DISPOSAL LOCATION WITH OWNERS REPRESENTATIVE
PRIOR TO DISPOSING OF ANY REMOVED ELECTRICAL EQUIPMENT.
3. EXISTING CIRCUIT INFORMATION SHOWN ON THE PLANS IS FOR REFERENCE ONLY. TRACE ALL EXISTING CIRCUITS AFFECTED
BY THIS WORK TO CONFIRM SOURCE PANEL AND CIRCUIT NUMBERS.
4. INFORMATION ON THE DRAWINGS HAS BEEN TAKEN FROM RECORD DRAWINGS. DEMOLITION DRAWINGS ARE INTENDED TO GIVE A COMMON BASIS FOR WORK. VISIT THE SITE, PRIOR TO FINAL PRICING AND BECOME FAMILIAR WITH THE EXTENT OF WORK REQUIRED. NO EXTRAS WILL BE ALLOWED FOR ALTERATIONS OF A FORESEEABLE NATURE REQUIRED TO ACHIEVE THE
END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS.
5. MAINTAIN FIRE ALARM SYSTEM OPERATION IN ALL AREAS OUTSIDE OF THE AREA OF WORK DURING CONSTRUCTION.
LIGHTING PROJECT NOTES
1. EXISTING CIRCUIT INFORMATION SHOWN ON THE PLANS IS FOR REFERENCE ONLY. TRACE ALL EXISTING CIRCUITS AFFECTED
BY THIS WORK TO CONFIRM SOURCE PANEL AND CIRCUIT NUMBERS.
2. UPPERCASE LETTER DENOTES LUMINAIRE TYPE. LOWERCASE LETTER INDICATES CONTROL ZONE.
3. EMERGENCY LUMINAIRES SHALL BE SWITCHED WITH THE REST OF THE LUMINAIRES IN THE ROOM OR AS INDICATED ON THE DRAWINGS BY LIGHTING CONTROL ZONE. PROVIDE ONE EMERGENCY TRANSFER RELAY PER CONTROL ZONE. RELAY SHALL BE
INSTALLED IN AN ACCESSIBLE LOCATION.
4. TO ACHIEVE THE INDICATED SEQUENCE OF OPERATION, PROVIDE ALL COMPONENTS AND DIMMING CABLING REQUIRED FOR THE LIGHTING CONTROL SYSTEM, WHETHER INDICATED OR NOT. REFER TO LIGHTING CONTROL SEQUENCE OF OPERATION
SCHEDULE FOR ADDITIONAL INFORMATION.
5. PROVIDE DIMMERS COMPATIBLE WITH LED DRIVERS AND POWER SUPPLIES PER MANUFACTURER'S RECOMMENDATIONS.
PROVIDE COMPONENTS AND ACCESSORIES TO ACCOMPLISH COMPLETE DIMMING FUNCTIONALITY AS SHOWN ON PLANS AND
NOTED IN THE LUMINAIRE SCHEDULE.
6. FOR LIGHT DIMMING BRANCH CIRCUITS, PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT CURRENT CARRYING CONDUCTOR. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX CURRENT CARRYING CONDUCTORS WITH PROPER DE-RATING AS REQUIRED BY NEC. PROVIDE FULL LENGTH STRIPING FOR DEDICATED NEUTRALS TO MATCH
ASSOCIATED CURRENT CARRYING CONDUCTOR COLOR.
7. LIGHTING CONTROLS COMMISSIONING SHALL COMPLY WITH IECC 2024, INCLUDING BUT NOT LIMITED TO COMMISSIONING DOCUMENTS, SYSTEM FUNCTIONAL TESTING, AND RECORD DOCUMENTS. REFER TO SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
COPYRIGHT, THE RMH GROUP, INC. 2025REV: 10/21/2024
m a k in g a d if fe re n c e t h ro u g h e n g in e e ri
W e st
C o lfa x A ve
L a ke w o o d
C O
P h o
-2
-0
D e n ve r
P h o e n ix
L o s
A n g e le s w w w .r m h g ro u p .c o m
M e c h a n ic a l
E le c tr ic a l In d u s tr ia l
S u s ta in a b il it y
S M
D a te
S c a le
D e s ig n e d B y
D ra w n B y
A p p ro v e d B y
P ro je c t
N o
P ro je c t
S ta tu s
SHT NO: REVISION
N o n e
/1
/2
:4
:2
A
M
C U s e rs \m b ru m a g e
\D o c u m e n ts
\2
-M
E T
R O
C A
V E
A L
IG
H
T
IN
G
M E
P m b ru m a g e .r v t
E-001
E L E
C T
R
IC
A L L
E G
E N
D
M E
T R
O S
T A
T E
U N
IV
E
R S
IT
Y
C A
V E
A L
IG
H
T
IN
G U
P G
R A
D E
J U
L Y
S R
J
M L B
S K
B
C D
R M
H -2
R E
V D
A T
E D
E S
C R
IP
T
IO
N
MM
MM
LEVEL 1
LEVEL 2
LEVEL 3
LEVEL 4
PENTHOUSE / ROOF
SPD
SOUTH
WING
NORTH
WING
EMH2BT-EML2B
L4B3T-L4B3
THEATER
H1BLCP1B
H2B L2B1
H3B
H4B
T-L2B1
L2B2
T-L2B2
L1B1
T-L1B1
L1B2
T-L1B2
L3B1
T-L3B1
L3B2
T-L3B2
L4B1
T-L4B1
L4B2
T-L4B2
STH3B
SUPPLYRETURN
400AT
400AF
LSIG
300AT
400AF
LSIG
60AT
60AF
SDS-B,
SUB-DISTRIBUTION SWITCHBOARD 'B'
2000A, 480/277V, 3∅, 4W, 65KAIC
400AT
400AF
LSIG
400AT
400AF
LSIG
400AT
400AF
LSIG
400AT
400AF
LSIG
150AT
400AF
LSIG
STL3B T-STL3B
200A3P
150A FUSE
CAVEA
DIM
EML2B
DIMMER
THEATER
110A3P110A3P
EMH2BT-EML2BEML2B
(3)
400AF
SPARE
SCHEDSCHED
SCHEDULE 60A5400A4G
SCHEDULE
400A4G400A4G
SCHEDULE
SCHEDULE SCHEDULE
400A4G
SCHEDULE SCHEDULE
SCHEDULE
SCHEDULE
SCHEDULE
SCHEDULE
SCHEDULE
SCHEDULE
SCHEDULE SCHEDULE
SCHEDULE
SCHEDULE
SCHEDULE
100A4G
SCHEDULE
P2000A4G
AHU-2AHU-2
SCHEDULE
SCHEDULE150A4G SCHEDULE
60A4G
M
SCHEDULE
SCHEDULESCHEDULE
ELEV-1 ELEV-2
SCHEDULESCHEDULESCHEDULE
100A4G
SCOPE OF WORK
m a k in g a d if fe re n c e t h ro u g h e n g in e e ri
W e st
C o lfa x A ve
L a ke w o o d
C O
P h o
-2
-0
D e n ve r
P h o e n ix
L o s
A n g e le s w w w .r m h g ro u p .c o m
M e c h a n ic a l
E le c tr ic a l In d u s tr ia l
S u s ta in a b il it y
S M
D a te
S c a le
D e s ig n e d B y
D ra w n B y
A p p ro v e d B y
P ro je c t
N o
P ro je c t
S ta tu s
SHT NO: REVISION
N O
N E
/1
/2
:4
:2
A
M
C U s e rs \m b ru m a g e
\D o c u m e n ts
\2
-M
E T
R O
C A
V E
A L
IG
H
T
IN
G
M E
P m b ru m a g e .r v t
E-002
E L E
C T
R
IC
A L O
N E
-L
IN
E D
IA
G
R A
M
M E
T R
O S
T A
T E
U N
IV
E
R S
IT
Y
C A
V E
A L
IG
H
T
IN
G U
P G
R A
D E
J U
L Y
S R
J
M L B
S K
B
C D
R M
H -2
SHEET NOTES
1. COORDINATE AND SCHEDULE ALL ELECTRICAL OUTAGES AND OUTAGE TIME FRAMES WITH OWNER’S REPRESENTATIVE AT LEAST TWO WEEKS PRIOR TO OUTAGE. ACCOMPLISH ALL PREP WORK PRIOR TO OUTAGE TO MINIMIZE THE OUTAGE TIME FRAME. SUBMIT A DETAILED METHOD OF PROCEDURE (MOP) FOR ALL OUTAGES FOUR WEEKS PRIOR TO OUTAGE. PERFORM OUTAGES DURING OFF HOURS AT A
TIME ACCEPTABLE BY THE OWNER.
2. PROVIDE TEMPORARY POWER FOR SMALL TOOLS AND TASK LIGHTING.
3. COMPLETELY REMOVE ALL UNUSED CONDUCTORS AND RACEWAYS BACK TO SOURCE. MARK UNUSED CIRCUIT BREAKERS AND FUSED SWITCHES THAT REMAIN AS “SPARE”. MAINTAIN CONTINUITY OF
CIRCUITS FOR ANY PORTIONS OF CIRCUITS TO REMAIN.
NONESCALE:E-002
PARTIAL ONE-LINE DIAGRAM - FOR REFERENCE ONLY1
R E
V D
A T
E D
E S
C R
IP
T
IO
S
S
OS
J J
S
S
OS
B
D2
D2
D2
D2
D2
D2D2
D2 D2
D2
D2
D2 D2
D2
D2 D2
D2
D2 D2
D2
D2
D2
D2
D2
D2 D2
D2
D2
D2
D2
D2 D2
D2
D2 D2
RW
RW
RW
WW
T
T
D2
D2
(E)COVE LIGHT
T1,e T1,e
T1,e
T1,e T1,e
D2
D2 D2
T1,eT1,e
CAVEA-1
CAVEA-1
EML2B-13
CAVEA-11
CAVEA-11
CAVEA-15
CAVEA-16
CAVEA-19
CAVEA-6
CAVEA-6
CAVEA-19
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-19
CAVEA-19
EML2B-13
CAVEA-6
CAVEA-6
CAVEA-19
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-19
CAVEA-19
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-4
CAVEA-18
a a h h h b b b b b b b b b b b b b b c c c cc c c c c c b b b b b b b b b b b b bb g
S12
(E)CAVEA DIM
PANEL
CAVEA-1
EML2B-13
CAVEA-4 CAVEA-4
(TYP.)
5 7
WW
CAVEA-18
WW
CAVEA-18
g g
WW
CAVEA-18
g
WW
CAVEA-18
WW
CAVEA-18
g g
WW
CAVEA-17
f
WW
CAVEA-17
WW
CAVEA-17
f f
WW
CAVEA-17
f
WW
CAVEA-17
WW
CAVEA-17
f f
CAVEA-2, j
CAVEA-10, i
RM,d RM,d RM,d RM,d
(E)
(E)
CAVEA-19
T1,e
T1,e
T1,e
T1,e
T1,e
T1,eCAVEA-19
T
T
B
(TYP.)
CAVEA-1
EML2B-13
CAVEA-11
CAVEA-11
CAVEA-18
CAVEA-18
CAVEA-18
CAVEA-17 CAVEA-17
CAVEA-17
CAVEA-7 CAVEA-4 CAVEA-4 CAVEA-4 CAVEA-4
CAVEA-16
CAVEA-16
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19
CAVEA-19 CAVEA-19
CAVEA-19
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-6
CAVEA-2
CAVEA-10
(E)CAVEA DIM
PANEL
3 CAVEA-73 CAVEA-213 CAVEA-213
CAVEA-1
CAVEA-1
EML2B-13
(E)COVE LIGHT
(E)
(E)
14 14 1414
15(TYP.)
15(TYP.)
15(TYP.)
15(TYP.)
m a k in g a d if fe re n c e t h ro u g h e n g in e e ri
W e st C o lfa x A ve
L a ke w o o d
C O
P h o
-2
-0
D e n ve r
P h o e n ix
L o s
A n g e le s w w w .r m h g ro u p .c o m
M e c h a n ic a l
E le c tr ic a l In d u s tr ia l
S u s ta in a b il it y
S M
D a te
S c a le
D e s ig n e d B y
D ra w n B y
A p p ro v e d B y
P ro je c t
N o
P ro je c t
S ta tu s
SHT NO: REVISION
/4
/1
/2
:0
:1
P
M
C U s e rs \s jo h n s o n \D o c u m e n ts \2
-M
E T
R O
C A
V E
A L
IG
H
T
IN
G M
E P
S h a ra
R M
H .r v t
E-114
P A
R T
IA
L
L
IG
H T
IN
G
P L
A N
L E
V E
L
M E
T R
O S
T A
T E
U N
IV
E
R S
IT
Y
C A
V E
A L
IG
H
T
IN
G U
P G
R A
D E
J U
L Y
S R
J
M L
B
S K
B
C D
R M
H -2
KEY NOTES #
1. DISCONNECT AND REMOVE EXISTING LUMINAIRES WITHIN AREA OF WORK. PRESERVE AND PROTECT
EXISTING BRANCH CIRCUITS FOR CONNECTION TO NEW LUMINAIRES.
2. DISCONNECT AND REMOVE EXISTING LUMINAIRE. PRESERVE AND PROTECT EXISTING BRANCH CIRCUIT
AND TRANSFER RELAY FOR CONNECTION TO NEW LUMINAIRE.
3. REMOVE EXISTING FLUORESCENT LAMP AND DISCONNECT EXISTING BRANCH CIRCUIT FROM
LUMINAIRE. LUMINAIRE SHALL BE ABANDONED IN PLACE.
4. PRESERVE AND PROTECT EXISTING OCCUPANCY SENSOR. REPROGRAM EXISTING SENSOR AS
DESCRIBED IN THE LIGHTING CONTROL SEQUENCE OF OPERATION SCHEDULE. IF EXISTING SENSOR IS
UNABLE TO BE REPROGRAMMED, REPLACE EXISTING SENSOR.
5. CONNECT NEW LUMINAIRES WITHIN AREA OF WORK TO EXISTING BRANCH CIRCUITS SALVAGED DURING DEMOLITION. PROVIDE ADDITIONAL CONDUIT AND WIRING TO EXTEND BRANCH CIRCUITS WHERE
REQUIRED.
6. CONNECT NEW LUMINAIRE TO EXISTING BRANCH CIRCUITS AND TRANSFER RELAY SALVAGED DURING DEMOLITION. RELAY SWITCHES LUMINAIRE TO EMERGENCY CIRCUIT UPON LOSS OF NORMAL POWER.
7. PROVIDE NEW BRANCH CIRCUIT TO NEW TRACK LIGHTING SYSTEM.
8. SURFACE MOUNT WALL WASH LUMINAIRE ON TOP OF LOWER OVAL CEILING AND SPACE EQUALLY BETWEEN LUMINAIRES, MAXIMIZE SPACING SO THAT LUMINAIRE MAINTAINS ADJUSTABILITY BETWEEN THE LOWER OVAL CEILING AND THE CEILING ABOVE. REFER TO LUMINAIRE MOUNTING DETAIL FOR
MORE INFORMATION.
9. PRESERVE AND PROTECT EXISTING 5-BUTTON CONTROL STATIONS. REPROGRAM EXISTING BUTTON
STATIONS AS SHOWN IN THE LOW-VOLTAGE SWITCH SCHEDULE.
10. WALL MOUNT REMOTE POWER SUPPLY FOR TYPE T TRACK LIGHTING NEAR CAVEA DIMMING PANEL, COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION.
11. SURFACE MOUNT REMOTE DRIVERS FOR TYPE WW WALL WASH LUMINAIRES ON TOP OF LOWER OVAL
CEILING, COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION.
12. EXISTING COVE LIGHTING SHALL REMAIN.
13. PROVIDE UL924 TRANSFER RELAY, BODINE GTD OR APPROVED EQUAL. RELAY SWITCHES LUMINAIRE
TO EMERGENCY CIRCUIT UPON LOSS OF NORMAL POWER.
14. DISCONNECT AND REMOVE MULTI-HEAD ADJUSTABLE DOWNLIGHT SECTIONS BETWEEN LENSED LINEAR SECTIONS (KEYNOTE 3). PRESERVE AND PROTECT EXISTING BRANCH CIRCUIT FOR CONNECTION TO
NEW LUMINAIRE.
15. RETURN EXISTING ETC TRACK, TRACKHEADS AND MONOPOINT LUMINAIRES TO OWNER.
SCALE: 1/4" = 1'-0"
PARTIAL LIGHTING INSTALLATION PLAN LEVEL 04
NONESCALE:E-114
PARTIAL LIGHTING DEMOLITION PLAN LEVEL 042
R E
V D
A T
E D
E S
C R
IP
T
IO
LOWER OVAL
APPROX. 9'-10"
SECOND OVAL
APPROX. 10'-9"
m a k in g a d if fe re n c e t h ro u g h e n g in e e ri
W e st C o lfa x A ve
L a ke w o o d
C O
P h o
-2
-0
D e n ve r
P h o e n ix
L o s
A n g e le s w w w .r m h g ro u p .c o m
M e c h a n ic a l
E le c tr ic a l In d u s tr ia l
S u s ta in a b il it y
S M
D a te
S c a le
D e s ig n e d B y
D ra w n B y
A p p ro v e d B y
P ro je c t
N o
P ro je c t
S ta tu s
SHT NO: REVISION
N O
N E
/1
/2
:0
:1
P
M
C U s e rs \s jo h n s o n \D o c u m e n ts \2
-M
E T
R O
C A
V E
A L
IG
H
T
IN
G M
E P
S h a ra
R M
H .r v t
E-601
E L E
C T
R
IC
A L S
C H
E D
U L
E S
M E
T R
O S
T A
T E
U N
IV
E
R S
IT
Y
C A
V E
A L
IG
H
T
IN
G U
P G
R A
D E
J U
L Y
S R
J
M L
B
S K
B
C D
R M
H -2
Version 0525 © 2026 all rights reserved
TOTAL 2.3 kW 2.4 kVA 3.0 kVA
MIN PANEL AMPACITY 8 AMPERES 0 % SPARE 0.0 @ 90% = 0.0 @ 0% = 0.0 kVA
PEAK LOAD 0.0 @ 90% = 0.0 @ 125% = 0.0 kVA
(%) -8 4 88 96 NONCOINCIDENT 0.0 @ 95% = 0.0 @ 0% = - kVA
PHASE BALANCE A-B B-C C-A PF CONT LOAD 0.0 @ 85% = 0.0 @ 125% = 0.0 kVA
OTHER 0.0 @ 85% = 0.0 @ 100% = 0.0 kVA
TOTAL 0.5 1.4 0.6 2.4 kVA EQUIPMENT 0.0 @ 85% = 0.0 @ 100% = 0.0 kVA
PEAK LOAD 0.0 0.0 0.0 0.0 kVA HEAT 0.0 @ 100% = 0.0 @ 125% = 0.0 kVA
NONCOINCIDENT 0.0 0.0 0.0 0.0 kVA KITCHEN 0.0 @ 80% = 0.0 @ 100% = 0.0 kVA
CONT LOAD 0.0 0.0 0.0 0.0 kVA REMAINDER 0.0 @ 80% = 0.0 @ 100% = 0.0 kVA
OTHER 0.0 0.0 0.0 0.0 kVA LARGEST 0.0 @ 80% = 0.0 @ 125% = 0.0 kVA
EQUIPMENT 0.0 0.0 0.0 0.0 kVA MOTORS
HEAT 0.0 0.0 0.0 0.0 kVA COMPUTER 0.0 @ 95% = 0.0 @ 125% = 0.0 kVA
KITCHEN 0.0 0.0 0.0 0.0 kVA REMAINDER 0.0 @ 95% = 0.0 @ 50% = - kVA
MOTOR 0.0 0.0 0.0 0.0 kVA FIRST 10 kVA 0.0 @ 95% = 0.0 @ 100% = 0.0 kVA
COMPUTER 0.0 0.0 0.0 0.0 kVA RECEPTACLES
RECEPTACLE 0.0 0.0 0.0 0.0 kVA LIGHTING 2.3 @ 95% = 2.4 @ 125% = 3.0 kVA
LIGHTING 0.5 1.4 0.6 2.4 kVA LOAD TYPE kW FACT kVA FACTOR LOAD
LOAD TYPE PH A PH B PH C TOTAL POWER DEMAND CALCULATED
PANEL LOADING SUMMARY NEC DEMAND LOAD SUMMARY
3. CONFIRM EXACT EXISTING ROUGH-IN DIMENSIONS PRIOR TO PROVIDING LUMINAIRE SUBMITTALS AND SHOP DRAWINGS
2. CONFIRM FINISHES WITH OWNER.
1. COORDINATE VOLTAGE AND MOUNTING CONFIGURATION WITH PLANS.
LUMINAIRE SCHEDULE NOTES:
WW 1,903 TUNABLE
WHITE
80+ SURFACE MOUNT WALL WASH WITH ASYMMETRIC
WALL WASH DISTRIBUTION; REMOTE DRIVER
WHITE SURFACE ELLIPTIPAR S100 - H-08 - E - 22 - M - 00 - 0 - TWH - DZ 0-10V
DOWN TO 1%
UNV 15
T1 1,745 TUNABLE
WHITE
80+ TRACKHEAD WITH FIELD ADJUSTABLE OPTICS WHITE TRACK WAC SILO
S2SA - 2 - F - TWA - WT
DMX
DOWN TO 1%
120 29
T N/A N/A N/A SURFACE MOUNT TRACK; PROVIDE COMPONENTS
AND ACCESSORIES REQUIRED FOR A COMPLETE
SYSTEM; PROVIDE POWER SUPPY FOR EACH
TRACK CONFIGURATION
WHITE SURFACE WAC VENTRIX SYSTEM
TRACK: S2 - CPS**
POWER SUPPLY: S2CPU - R - 320 - X - BK
-- 120 --
RW 2,661 TUNABLE
WHITE
80+ SEMI-RECESSED RETROFIT WALLWASH WITH
ASYMMETRIC WALL WASH DISTRUBUTION;
PROVIDE MODIFIED TRIM TO COVER EXISTING
ROUGH-IN
EXISTING APPROXIMATE ROUGH-IN: 9-1/8" x 23-1/2"
WHITE RECESSED ELLIPTIPAR S224 - S24 - T -22 - M - XX - 0 - TWH - DZ 0-10V
DOWN TO 1%
UNV 22
RM 850 TUNABLE
WHITE
80+ RECESSED LINEAR SLOT WITH MULTIHEAD
ADJUSTABLE DOWNLIGHTS AT 9" SPACING;
PROVIDE MODIFIED TRIM TO COVER EXISTING
ROUGH-IN
EXISTING APPROXIMATE ROUGH-IN: 5.43" OPENING
x 3' LENGTH
BLACK RECESSED ZANIBONI D4-D03RM - 13 - TD - 80 - 60 - S - BK - Z0 - ** - R0 - D 0-10V
DOWN TO 1%
UNV 9W EACH
DOWNLIGHT
D2 666 TUNABLE
WHITE
80+ PINHOLE RECESSED RETROFIT DOWNLIGHT,
MEDIUM 40 DEGREE DISTRIBUTION, DIFFUSE
CLEAR FINISH
EXISTING APPROXIMATE ROUGH-IN: 3.63"
DIAMETER
WHITE RECESSED LUMENPULSE LUMENCORE NANO DOWNLIGHT
R - SB - RD - * - DWH - M - MWH - MWH - RM - 120 -
DAMC
0-10V
DOWN TO 1%
120 8.5
KEY LUMENS CCT CRI DESCRIPTION (NOTE 2) (NOTE 1) MANUFACTURER CATALOG NUMBER DIMMING VOLTS VA NOTES
LED SOURCE FINISH MOUNTING SPECIFICATION (NOTE 1)
Contact: Shara... Email: sjohnson@rmhgroup.com
LUMINAIRE SCHEDULE
S12 VACANCY SENSING, LOCAL MANUAL DIMMING STAND ALONE X X 15 MINUTE
LIGHTS SHALL BE MANUAL ON AND AUTOMATIC OFF WHEN
THE SPACE IS VACANT.
LOCAL DIMMING CONTROL.
KEY DESCRIPTION
CONTROL SYSTEM
TYPE
VACANCY
(MANUAL ON,
AUTO OFF)
OCCUPANCY
(AUTO ON,
AUTO OFF)
TIMECLOCK
LOCAL MANUAL
SWITCHING
LOCAL
MANUAL
DIMMING
SENSOR TIME
DELAY
PHOTOSENSOR
DIMMING
PHOTOSENSOR ON/OFF NOTES
LIGHTING CONTROL SEQUENCE OF OPERATION SCHEDULE
5. LOAD REMOVED EXCEEDS LOAD ADDED, NO NET NEW LOAD
4. NEW MODULE, NEW LOAD
3. EXISTING MODULE, LOAD REMOVED
2. EXISTING MODULE, NEW LOAD
1. EXISTING MODULE, EXISTING LOAD
NOTES
R20 RELAY
ELV10 REVERSE PHASE DIMMING
D20 FORWARD PHASE DIMMING
CC CONSTANT CURRENT - POWER ONLY - NO CONTROL
CONTROLS KEY
24 24 CAVEA UNCONTROLLED PWR FOR SENSING FOR EM LTG NON-DIM
23 23 CAVEA UNCONTROLLED PWR FOR SENSING FOR EM LTG
CC20
NON-DIM
C 1
22 18 CAVEA SPARE 0
21 17 CAVEA SPARE
D20
C 3
20 12 CAVEA SPARE 0
19 11 CAVEA c FRONT DOWNLIGHTS R20
0-10V 187 C 4
18 6 CAVEA g SOUTH WALL WASH 0-10V 180
17 5 CAVEA f NORTH WALL WASH R20
0-10V 180 C 4
16 22 CAVEA e SOUTH TRACK LTG DMX 116
15 21 CAVEA e NORTH TRACK LTG R20
DMX 116
B 2
14 16 CAVEA SPARE 0
13 15 CAVEA SPARE
D20
B 1
12 10 CAVEA SPARE 0
11 9 CAVEA a EXIT DOWNLIGHTS R20
0-10V 17 B 4
10 4 CAVEA h LOWER RING LTG DMX 1068
9 3 CAVEA SPARE
R20
B 1
8 20 CAVEA SPARE 0
7 19 CAVEA SPARE
D20
A 3
6 14 CAVEA b REAR DOWNLIGHTS 0-10V 136
5 13 CAVEA SPARE
R20
A 4
4 8 CAVEA d CENTER DOWNLIGHTS 0-10V 112
3 7 CAVEA SPARE
R20
A 4
2 2 CAVEA i UPPER RING LTG DMX 237
1 1 CAVEA a REAR WALL WASH R20
0-10V 66 A 2
DIMMER #
& DMX
ADDRESS
LOAD
LUG # IN
PANEL
ROOM
NUMBER ZONE DESCRIPTION
DIMMER
MODULE
TYPE LOAD TYPE LOAD PHASE
VIA EM
TRANSFER
SWITCH NOTES
22,000 AIC (NOTE 5)
225A MLO LOW-VOLTAGE DIMMING OPTION CARD
VOLTAGE: 208/120V, 3Ph, 5W DRd12 - 24 - 120 UNISON DIMMER PANEL CHASSIS
FED FROM: (E) L4B3 ETC 120V, 24 CIRCUIT DIMMER PANEL
(E)CAVEA DIMMING PANEL
NONESCALE:E-601
TYPE WW - WALL WASH DETAIL1
R E
V D
A T
E D
E S
C R
IP
T
IO
N
2. COORDINATE COLOR SETTINGS WITH OWNER DURING PROGRAMMING.
1. COORDINATE FINAL SCENE DIM LEVELS AND COLOR TEMPERATURES WITH OWNER DURING PROGRAMMING.
GENERAL NOTES:
5 ALL OFF a - f ALL ZONES 0% 3500K j UPPER RING LTG 100% NOTE 2 i LOWER RING LTG 100% NOTE 2 h REAR WALL WASH 0% 3500K g SOUTH WALL WASH 0% 3500K f NORTH WALL WASH 0% 3500K e
TRACK LIGHTS
(each head individually addressed)
0% 3500K d CENTER DOWNLIGHTS 10% 3500K c FRONT DOWNLIGHTS 10% 3500K b REAR DOWNLIGHTS 10% 3500K
4 SCREENING
a EXIT DOWNLIGHTS 0% 3500K j UPPER RING LTG 100% NOTE 2 i LOWER RING LTG 100% NOTE 2 h REAR WALL WASH 0% 3500K g SOUTH WALL WASH 0% 3500K f NORTH WALL WASH 100% 3500K e
TRACK LIGHTS
(each head individually addressed)
100% 3500K d CENTER DOWNLIGHTS 100% 3500K c FRONT DOWNLIGHTS 100% 3500K b REAR DOWNLIGHTS 100% 3500K
3 STANDARD 2
a EXIT DOWNLIGHTS 100% 3500K j UPPER RING LTG 100% NOTE 2 i LOWER RING LTG 100% NOTE 2 h REAR WALL WASH 100% 3500K g SOUTH WALL WASH 100% 3500K f NORTH WALL WASH 100% 3500K e
TRACK LIGHTS
(each head individually addressed)
100% 3500K d CENTER DOWNLIGHTS 100% 3500K c FRONT DOWNLIGHTS 100% 3500K b REAR DOWNLIGHTS 100% 3500K
2 STANDARD 1
a EXIT DOWNLIGHTS 100% 3500K
(E)
1 ALL ON a - f ALL ZONES 100% 3500K
LV SWITCH TAG BUTTON DESCRIPTION ZONES CONTROLLED DIM LEVELS
COLOR TEMPERATURE
/ COLOR
NOTES
LOW-VOLTAGE SWITCH SCHEDULE
m a k in g a d if fe re n c e t h ro u g h e n g in e e ri
W e st
C o lfa x A ve
L a ke w o o d
C O
P h o
-2
-0
D e n ve r
P h o e n ix
L o s
A n g e le s w w w .r m h g ro u p .c o m
M e c h a n ic a l
E le c tr ic a l In d u s tr ia l
S u s ta in a b il it y
S M
D a te
S c a le
D e s ig n e d B y
D ra w n B y
A p p ro v e d B y
P ro je c t
N o
P ro je c t
S ta tu s
SHT NO: REVISION
/2
/2
:4
:1
P
M
C U s e rs \m b ru m a g e
\D o c u m e n ts
\2
-M
E T
R O
C A
V E
A L
IG
H
T
IN
G
M E
P m b ru m a g e .r v t
E-602
L
IG
H T
IN
G
C O
M C
H E
C K
M E
T R
O S
T A
T E
U N
IV
E
R S
IT
Y
C A
V E
A L
IG
H
T
IN
G U
P G
R A
D E
J U
L Y
S R
J
M L B
S K
B
C D
R M
H -2
R E
V D
A T
E D
E S
C R
IP
T
IO
N
/2
/2
R
E S
P O
N S
E T
O C
O M
M E
N T
S
09.21.2026
File details come from the government source that posted it. Updated .