Appendix F - Code Requirements.pdf
PDF 121 KB Posted
- Attached to
- Roof Replacement
- Solicitation number
- 3-24-2025
- Issued by
- Adams County, Pueblo City, Colorado
About this file
Appendix F is a document from Professional Construction Services detailing the Building Code Requirements for a roof replacement project governed by the Pueblo Regional Building Department (PRBD) in Colorado. The document specifies the adoption of 2021 international building codes, including the Residential Code (IRC), Energy Conservation Code (IECC), and Plumbing Code (IPC), all with amendments by PRBD. The climatic and geographic design criteria are also outlined, including a 115 mph basic wind speed, Exposure C, Risk Category III, and a ground snow load of 20 PSF.
The building code requirements are specifically referenced to determine the conditions for repair or replacement of an existing roof. A portion of the listed building codes is available in a project folder at a provided Box.com link. The document serves as a technical appendix for contractors to understand the precise building code standards and environmental considerations that must be adhered to during the roof replacement project, ensuring compliance with local jurisdictional requirements and safety standards.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Professional Construction Services 11877 W. 80th Ave. Arvada, CO 80005
Phone: 720-340-7530 Fax: 866-459-3334
Appendix F Building Code Requirements
The current building codes for this property are those adopted by the Pueblo Regional Building Department (PRBD) which is the authority having jurisdiction (AHJ). The manufacturers’ installation instructions are part of the building codes by reference. The entire 2021 building code as adopted and amended by PRBD is included here by reference.
Building Code Requirements
1. 2021 international Residential Code (IRC) with Amendments by
PRBD.
2. 2021 international Energy Conservation Code (IECC) with Amendments by PRBD.
3. 2021 international Plumbing Code (IPC) with Amendments by
PRBD.
4. 2021 international Plumbing Code (IPC) with Amendments by
PRBD.
5. Climatic and geographic design criteria as adopted by the Pueblo Regional Building Department
i. 115 mph basic wind speed
ii. Exposure C (based on existing location and exposure)
iii. Risk Category III (based on building usage)
iv. Ground Snow Load 20 PSF
The referenced code determines the conditions that are required for the repair or replacement of the existing roof.
A portion of the listed building codes are provided within the project folder inside the Code Requirements sub-folder at the following link:
https://app.box.com/s/gie1slejwf1j54c1pxvd9t3z8rw5gnme https://app.box.com/s/gie1slejwf1j54c1pxvd9t3z8rw5gnme
Professional Construction Services 11877 W. 80th Ave. Arvada, CO 80005
Phone: 720-340-7530 Fax: 866-459-3334
File details come from the government source that posted it. Updated .