Appendix A - Roof Diagrams.pdf

PDF 3 MB Posted

Attached to
Roof Replacement
Solicitation number
3-24-2025
Issued by
Adams County, Pueblo City, Colorado

About this file

The document is a comprehensive roof measurement and assessment report for the Pueblo West Library located at 298 S. Joe Martinez Boulevard in Pueblo West, Colorado, prepared by Professional Construction Services. The report includes detailed roof diagrams, aerial imagery, and precise measurements of a multi-building facility with a total roof area of 15,714 square feet, comprised of 11 distinct roof facets. The predominant roof pitch is 1/12, with 13,999 square feet of flat roofing and 1,715 square feet of pitched roofing. The roof images reveal a complex structure with blue and white roofing sections, multiple building segments, and surrounding parking areas.

The roof measurement report provides granular data including 661 feet 10 inches of wall flashing, 149 feet 5 inches of step flashing, and 721 feet 8 inches of parapet wall. The report includes recommended waste percentages for roofing materials ranging from 0% to 20%, with corresponding area calculations. The document appears to be part of a preliminary assessment for a potential roof replacement or renovation project, offering detailed technical specifications that would be valuable for contractors bidding on the roofing work. The report was generated using Roofr technology and is dated 03/15/2025, suggesting this is a prospective future project planning document.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Professional Construction Services

11877 W. 80th Ave. Arvada, CO 80005 Phone: 720-340-7530

Fax: 866-459-3334

Appendix A Roof Diagrams and Measurements

Roof Diagram

���������������������������
��������
���������������������������
��������
���������������������������
��������
�����
��������

���/0�

��- 1

�� 2

��/0�

�,/0� �,/0�

�,/0�

�3/0%

�3/0%

�3/0%

�3/0%

�3/0%

�3/0%

�3/0�

�3/0�

�3/0�

�3/0�

�3/0�

�3/0�

*�/0� *�/0*

��/0, ��/0�

���/0�

%,/0�

��/0�

��/0��

%,/0�

��/0���/03

��/0� ��/0��

�,/0, ��- 1

��- 1

�3- 1

�,- 1

�- 1

*�- 1

��- 1

��- 1

3- 1

��- 1

*�- 1

���������������������������
��������

���/0�

��- 1

�� 2

��/0�

�,/0� �,/0�

�,/0�

�3/0%

�3/0%

�3/0%

�3/0%

�3/0%

�3/0%

�3/0�

�3/0�

�3/0�

�3/0�

�3/0�

�3/0�

*�/0� *�/0*

��/0, ��/0�

���/0�

%,/0�

��/0�

��/0��

%,/0�

��/0���/03

��/0� ��/0��

�,/0, ��- 1

��- 1

�3- 1

�,- 1

�- 1

*�-1
��-1 ��-1

3- 1

��- 1

*�- 1

Roof

Measurement Report

Roof Report 15714 sqftPrepared by Professional Construction Services

11 facets

Predominant pitch 1/12298 South Joe Martinez Boulevard, Pueblo West, CO 81007

This report was prepared by Professional Construction Services. Copyright © 2025 Roofr.com | All rights reserved. 1

Powered by

Diagram 298 South Joe Martinez Boulevard, Pueblo West, CO 81007

This report was prepared by Professional Construction Services. Copyright © 2025 Roofr.com | All rights reserved. 2

Length measurement report 298 South Joe Martinez Boulevard, Pueblo West, CO 81007

Eaves: 0ft 0in Valleys: 0ft 0in Hips: 0ft 0in Ridges: 0ft 0in Rakes: 0ft 0in Wall flashing: 661ft 10in Step flashing: 149ft 5in Transitions: 0ft 0in Parapet wall: 721ft 8in Unspecified: 1654ft 2in

55 97

230 30 30 30

Measurements in diagram are rounded up for display. Some edge lengths may be hidden from diagram to avoid overcrowding.

This report was prepared by Professional Construction Services. Copyright © 2025 Roofr.com | All rights reserved. 3

Area measurement report 298 South Joe Martinez Boulevard, Pueblo West, CO 81007

Total roof area: 15714 sqft Predominant pitch: 1/12 Pitched roof area: 1715 sqft Predominant pitch area: 13550 sqft Flat roof area: 13999 sqft Unspecified pitch area: 2164 sqft Two story area: 0 sqft Two layer area: 0 sqft

Flat

Flat

Flat 12,338

Flat

Flat

59032 34

Flat

Area measurements in diagram are rounded. The totals at the top of the page are the sums of the exact measurements, which are then rounded. Deleted facets (skylights, chimneys, etc.) are designated with a dashed line and are excluded from the calculations.

This report was prepared by Professional Construction Services. Copyright © 2025 Roofr.com | All rights reserved. 4

Pitch & direction measurement report 298 South Joe Martinez Boulevard, Pueblo West, CO 81007

N/A N/A

N/A

N/A

N/AN/A N/A

Deleted facets are designated with a dashed line and do not have a pitch.

This report was prepared by Professional Construction Services. Copyright © 2025 Roofr.com | All rights reserved. 5

Report summary 298 South Joe Martinez Boulevard, Pueblo West, CO 81007

Measurements

Total roof area 15714 sqft

Total pitched area 1715 sqft

Total flat area 13999 sqft

Total roof facets 11 facets

Predominant pitch 1/12

Total eaves 0ft 0in

Total valleys 0ft 0in

Total hips 0ft 0in

Total ridges 0ft 0in

Total rakes 0ft 0in

Total wall flashing 661ft 10in

Total step flashing 149ft 5in

Total transitions 0ft 0in

Total parapet wall 721ft 8in

Total unspecified 1654ft 2in

Hips + ridges 0ft 0in

Eaves + rakes 0ft 0in

Pitch N/A 1/12

Area (sqft) 2,165 13,550

Squares 21.7 135.5

Recommended

Waste % 0% 2% 10% 12% 15% 17% 20%

Area (sqft) 15,714 16,029 17,286 17,600 18,071 18,386 18,857

Squares 157.2 160.3 172.9 176.0 180.8 183.9 188.6

Recommended waste is based on an asphalt shingle roof with a closed valley system (if applicable). Several other factors are involved in determining which waste percentage to use, including the complexity of the roof and individual roof application style. You will also need to calculate the post-waste quantity of other materials needed (hip and ridge caps, starter shingle, etc.).

This report was prepared by Professional Construction Services. Copyright © 2025 Roofr.com | All rights reserved. 6

File details come from the government source that posted it. Updated .