This is a technical drawing for the St. Petersburg, Florida Water Supply System, specifically focused on modifications to the Cosme Treatment Plant's aerator tank and outlet structures. The detailed engineering schematic shows multiple views and cross-sections of Outlet Structures No. 1, No. 2, No. 3, and No. 4, including plan views, elevations, and detailed sectional diagrams. The drawing provides comprehensive technical specifications for the aeration tank, grating, and overflow box, with precise measurements and structural details for each outlet structure.

The drawing is prepared by Greeley and Hansen Engineers, located in Chicago, and is part of a project documenting miscellaneous structures and aerator modifications. The technical specifications include detailed measurements for various structural elements, highlighting the precise engineering requirements for the water treatment plant's infrastructure. While the drawing does not directly indicate cost or contract terms, it serves as a critical technical reference for the water supply system improvement project in St. Petersburg, Florida, providing engineers and contractors with exact structural details necessary for potential renovation or maintenance work.

View the file

Other files

File Type Posted
Aerator_Tank_&_Flume_Clean_and_Recoating_of_Interior_and_Exterior_of_Aerator_tanks_and_Flumes_(Addendum_#7_Revision).pdf PDF
Sign_in_Sheet_Pre-bid_site_inspection_2.pdf PDF
Aerator_Roof_Railing.jpeg JPEG file
Aerator_Railing_Roof_Perimeter.jpeg JPEG file
Railing_Stair_Tread.jpeg JPEG file
Aerator_Louver_Screen_System.jpeg JPEG file
Aerator_to_Aerator_Bridge.jpeg JPEG file
Aerator_Interior_Lighting.jpg JPG image
Aerator_Stairs_and_Flume.jpeg JPEG file
Flume_Walkway_2.jpg JPG image
Flume_Walkway_1_and_2.jpg JPG image
Flume_Walkway.jpg JPG image
Interior_4.jpg JPG image
Interior_3.jpg JPG image
Interior_2.jpg JPG image
Interior_1.jpg JPG image
GST_1_Investigative_Exterior.jpg JPG image
12.1999_PROJECT_99406-113_Aerator_repairs.pdf PDF
Aerator_Structural_Details.pdf PDF
Coatings_Part_B_PROJECT#_99406-113_.jpg JPG image
Coatings_Part_A_PROJECT#_99406-113.jpg JPG image
Alternate_Coating:_Tnemec_Approved_Equal_.pdf PDF
Noise_Guideline_.pdf PDF
Sign_in_Sheet_2_Pre-Bid.pdf PDF
Sign_In_Sheet_1_Pre-bid.pdf PDF
Appendix_H_-_Exterior_Screens.jpeg JPEG file
Appendix_B.1_-Drawing_#3088_As_Built_-_Pg17_2.pdf PDF
Appendix_B_-_Drawing_COSME_WTP_AERATOR_19750419_20181128_(005).pdf PDF
Appendix_A_-_Aerial_Photo.PNG PNG image
Light_Construction_v_04.docx DOCX document
Public_Construction_Bond-Construction_(00525880).docx DOCX document
Bid_Bond_(00525848).docx DOCX document
A-01._Bid_Bond_(00525848).docx DOCX document
COSME_AERATOR_SPEC.docx DOCX document
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .