Appendix A - Wylie Elementary Drawings.pdf

PDF 14 MB Posted

Attached to
Wylie, Dexter High School, Dexter Field House Technology
Solicitation number
RFP DEXT 260000002142 1
Issued by
Washtenaw County, Detroit City, Michigan

About this file

This document comprises technical construction drawings and specifications for the Wylie Elementary Classroom Addition project in the Dexter Community School District, Michigan, prepared by Commtech Design and TMP Architecture. The drawings detail comprehensive technology infrastructure including data communications, audio/video systems, security, and access control installations for the new classroom addition. The project encompasses CAT-6 and CAT-6A cabling systems (color-coded by function: blue for data, green for security cameras, yellow for wireless access points, violet for tie panels, and brown for clock/paging), fiber optic backbone connectivity, 86-inch interactive LCD displays in classrooms, IP-based clock and paging systems, and extensive security camera and access control systems. The drawings specify equipment manufacturers and part numbers, installation standards requiring laser-printed labeling on all cables and panels, cable support requirements (J-hooks minimum every five feet), and detailed rack layouts for communications rooms. Multiple construction details address cable routing, grounding requirements, and integration of various systems including telecommunications ground bars, patch panels, network switches, and power distribution equipment.

The drawings establish rigorous installation standards including comprehensive labeling protocols with wrap-around laser-printed self-laminating labels at cable termination points, strict prohibition on cable attachment to building steel or HVAC ducts, and mandatory use of approved conduit and raceway systems. Grounding specifications require minimum #6 AWG cable with crimp lugs and phosphor bronze fasteners connected to telecommunications ground bars bonded to building steel. The security system integration includes IP-based access control with proximity card readers, electronic latch retractors, assisted door openers, and interconnected panels requiring Ethernet connectivity to communications room switches and 120-volt hardwired power connections. Audio/video systems require professional installation of ceiling speakers, patch cables, and component storage panels behind flat panel displays. All cabling must be plenum-rated in plenum areas, and the contractor must coordinate with the owner and other trades regarding final equipment locations, heights, and system configurations prior to installation and testing.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TC101

TYPICAL FACEPLATE LABELING

TC101

TYPICAL CABLE LABELING

AT FACEPLATE & PATCH PANEL

TC101

CAMERA OR WIRELESS PANEL LABELING

TC101

CAT-6 DATA PANEL LABELING

ABBREVIATIONS

ABBREV. DESCRIPTION ABBREV. DESCRIPTION

COMMUNICATION SYMBOL LEGEND

SYMBOL DESCRIPTION

CABLE SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

COMMUNICATION EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

TC101

COMMUNICATIONS GROUNDING DETAIL

Commtech

AutoCAD SHX Text NOTES: 1. INSTALL A PAPER LABEL BEHIND THE PLASTIC WINDOW IN STANDARD PLATES INSTALL A PAPER LABEL BEHIND THE PLASTIC WINDOW IN STANDARD PLATES THAT ARE EQUIPPED WITH THE WINDOWS. 2. PROVIDE ADHESIVE LABELS ON WALL PHONE PLATES & SURFACE MOUNT PROVIDE ADHESIVE LABELS ON WALL PHONE PLATES & SURFACE MOUNT OUTLETS & PLATES WITHOUT LABELING WINDOWS.

AutoCAD SHX Text DATA CABLE LABEL: A = COMMUNICATIONS ROOM, A, B, ETC. Y = PATCH PANEL IN THAT RACK OR CABINET 1-X CC = PORT ON THAT PANEL FROM 01-24

AutoCAD SHX Text

ADHESIVE LABEL

AutoCAD SHX Text

PAPER BEHIND WINDOW

AutoCAD SHX Text

CAT-6 CABLE

AutoCAD SHX Text

BACK OF FACEPLATE

AutoCAD SHX Text NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. 2. WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE SELF-LAMINATING.

AutoCAD SHX Text CABLE LABEL: A = COMMUNICATIONS ROOM NUMBER. A, B OR C ETC. Y = PATCH PANEL IN THAT COMMUNICATIONS ROOM CC = PORT NUMBER ON PATCH PANEL 0-24. DDD = CAMERA OR WAP NUMBER

AutoCAD SHX Text NOTES: 1. INSTALL A LABEL TO EACH PATCH PANEL DETAILING THE COMM INSTALL A LABEL TO EACH PATCH PANEL DETAILING THE COMM ROOM NUMBER AND PATCH PANEL NUMBER. EACH PANEL IS PRE-NUMBERED 01-24 ON EACH PANEL. 2. ALL LABELS ADDED TO THE PANEL SHALL BE LASER PRINTED AND ALL LABELS ADDED TO THE PANEL SHALL BE LASER PRINTED AND CUT TO FIT. ALL NUMBERS SHALL EXACTLY ALIGN WITH THE LOCATION ON THE PATCH PANEL. 3. IF THE PANEL IS NOT PRE-LABELED 01-24 THEN THE IF THE PANEL IS NOT PRE-LABELED 01-24 THEN THE CONTRACTOR SHALL INSTALL A LABEL FOR EACH PORT. 4. INDIVIDUAL CABLES AT A SINGLE FACEPLATE SHALL BE LABELED IN INDIVIDUAL CABLES AT A SINGLE FACEPLATE SHALL BE LABELED IN SEQUENCE AS PER THE PATCH PANEL. 5. THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL IN THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL IN NUMERICAL ORDER. NO EXCEPTIONS.

AutoCAD SHX Text DATA CABLE LABELING A-Y-CC A = COMMUNICATIONS ROOM NUMBER. A, B OR C ETC. Y = PATCH PANEL IN THAT COMMUNICATIONS ROOM CC = PORT NUMBER ON PATCH PANEL 0-24.

AutoCAD SHX Text

LABEL PATCH PANELS CONSECUTIVELY IN THE COMM ROOM, 1-99

AutoCAD SHX Text

COMM ROOM DESIGNATOR. A OR IDF1 ETC. SEE FLOOR PLANS

AutoCAD SHX Text

ADHESIVE LABEL (TYPICAL)

AutoCAD SHX Text NOTES: 1. INSTALL A LABEL TO EACH PATCH PANEL DETAILING THE COMM INSTALL A LABEL TO EACH PATCH PANEL DETAILING THE COMM ROOM NUMBER AND PATCH PANEL NUMBER. EACH PANEL IS PRE-NUMBERED 01-24 ON EACH PANEL. 2. ALL LABELS ADDED TO THE PANEL SHALL BE LASER PRINTED AND ALL LABELS ADDED TO THE PANEL SHALL BE LASER PRINTED AND CUT TO FIT. ALL NUMBERS SHALL EXACTLY ALIGN WITH THE LOCATION ON THE PATCH PANEL. 3. IF THE PANEL IS NOT PRE-LABELED 01-24 THEN THE IF THE PANEL IS NOT PRE-LABELED 01-24 THEN THE CONTRACTOR SHALL INSTALL A LABEL FOR EACH PORT. 4. THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL IN THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL IN NUMERICAL ORDER. NO EXCEPTIONS. 5. ADD LABELS FOR CAMERA NUMBERS OR WAP NUMBERS DEPENDING ADD LABELS FOR CAMERA NUMBERS OR WAP NUMBERS DEPENDING UPON PATCH PANEL. SEE RACK LAYOUTS TO DETERMINE IF CAMERA AND WAP CABLES WILL BE ON SEPARATE OR SHARED PATCHPANELS

AutoCAD SHX Text DATA CABLE LABELING A-Y-CC A = COMMUNICATIONS ROOM NUMBER. A, B OR C ETC. Y = PATCH PANEL IN THAT COMMUNICATIONS ROOM CC = PORT NUMBER ON PATCH PANEL 1-24. DDD = CAMERA NUMBER. MEET WITH OWNER AND SECURITY CONTRACTOR TO OBTAIN THIS NUMBER WAP = WAP NUMBER. MEET WITH OWNER TO OBTAIN THIS NUMBER

AutoCAD SHX Text

LABEL PATCH PANELS CONSECUTIVELY IN THE COMM ROOM, 1-99

AutoCAD SHX Text

COMM ROOM DESIGNATOR. A OR IDF1 ETC. SEE FLOOR PLANS

AutoCAD SHX Text

ADHESIVE LABEL (TYPICAL)

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text

DDD

AutoCAD SHX Text ADHESIVE LABEL (TYPICAL). COORDINATE WITH OWNER AND OTHER CONTRACTORS TO OBTAIN DEVICE NUMBERS. ADD THESE TO THE PANEL

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

WAP

AutoCAD SHX Text

AY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DDD

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AY

AutoCAD SHX Text

DATA

AutoCAD SHX Text

DATA

AutoCAD SHX Text

BLANK

AutoCAD SHX Text

DATA

AutoCAD SHX Text

DATA

AutoCAD SHX Text

CC

AutoCAD SHX Text

CC

AutoCAD SHX Text A-Y

AutoCAD SHX Text A-Y

AutoCAD SHX Text

CC

AutoCAD SHX Text

CC

AutoCAD SHX Text

STANDARD PLATE

AutoCAD SHX Text

PHONE PLATE

AutoCAD SHX Text

A-Y-CC

AutoCAD SHX Text

DATA

AutoCAD SHX Text

A-Y-CC

AutoCAD SHX Text

SURFACE MOUNT OUTLET

AutoCAD SHX Text

AY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AY

AutoCAD SHX Text

WRAP-AROUND LABEL

AutoCAD SHX Text

A-Y-CC

AutoCAD SHX Text

A-Y-CC

AutoCAD SHX Text

WRAP-AROUND LABEL

AutoCAD SHX Text

BACK OF PATCH PANEL IN COMM ROOM

AutoCAD SHX Text 33-3204-02

AutoCAD SHX Text 33-3204-02

AutoCAD SHX Text

INSTALL REAR CABLE ORGANIZER ON EACH PANEL

AutoCAD SHX Text 2G

AutoCAD SHX Text

TWO-GANG BOX - PROVIDED BY EC

AutoCAD SHX Text

NIC

AutoCAD SHX Text

NOT IN CONTRACT

AutoCAD SHX Text

AC

AutoCAD SHX Text ABOVE COUNTER - INSTALL BACKBOX SAME HEIGHT AS OTHER ELECTRICAL OUTLETS ABOVE THE COUNTER.

AutoCAD SHX Text

PBO

AutoCAD SHX Text

PROVIDED BY OTHERS

AutoCAD SHX Text

AFF

AutoCAD SHX Text

ABOVE FINISHED FLOOR

AutoCAD SHX Text

PCO-1

AutoCAD SHX Text

PATCH CORD ORGANIZER - 1 UNIT HIGH

AutoCAD SHX Text

AFG

AutoCAD SHX Text

ABOVE FINISHED GROUND

AutoCAD SHX Text

PCO-2

AutoCAD SHX Text

PATCH CORD ORGANIZER - 2 UNITS HIGH

AutoCAD SHX Text

AWG

AutoCAD SHX Text

AMERICAN WIRE GAUGE

AutoCAD SHX Text

PET

AutoCAD SHX Text

PROTECTED ENTRANCE TERMINAL

AutoCAD SHX Text

EMT

AutoCAD SHX Text

EMT TYPE CONDUIT

AutoCAD SHX Text

QTY

AutoCAD SHX Text

QUANTITY

AutoCAD SHX Text

EC

AutoCAD SHX Text

ELECTRICAL CONTRACTOR

AutoCAD SHX Text THIS SYMBOL WITH A NUMBER INSIDE REFERS TO KEYNOTES. REFER TO NOTES ON THE SHEET OR WITHIN THE DETAIL FOR ADDITIONAL INFORMATION

AutoCAD SHX Text EQUIPMENT SCHEDULE. THIS SYMBOL WITH LETTERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.

AutoCAD SHX Text CABLE SCHEDULE. THIS SYMBOL WITH NUMBERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.

AutoCAD SHX Text DATA COMMUNICATIONS OUTLET CONNECTIVITY CODE. X IS A 1 THRU 99. SEE TC1XX SHEETS FOR SPECIFIC REQUIREMENTS. XXXX NOTES THAT THE CABLE IS FOR A SPECIFIC USE

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text X

AutoCAD SHX Text

XXXX

AutoCAD SHX Text

CAT-6 UTP CABLES FOR DATA COMMUNICATIONS SHALL BE BLUE IN COLOR

AutoCAD SHX Text

MOHAWK

AutoCAD SHX Text M58281

AutoCAD SHX Text

CAT-6 UTP CABLES FOR SECURITY CAMERAS SHALL BE GREEN IN COLOR

AutoCAD SHX Text

MOHAWK

AutoCAD SHX Text M58286

AutoCAD SHX Text

CAT-6A UTP CABLES FOR WIRELESS ACCESS POINTS SHALL BE YELLOW IN COLOR

AutoCAD SHX Text

MOHAWK

AutoCAD SHX Text M59148

AutoCAD SHX Text

CAT-6 UTP CABLES FOR TIE PANELS BETWEEN COMM ROOMS SHALL BE VIOLET IN COLOR

AutoCAD SHX Text

MOHAWK

AutoCAD SHX Text M58290

AutoCAD SHX Text

CAT-6 UTP CABLES FOR CLOCK/PAGING CONNECTIVITY SHALL BE BROWN IN COLOR

AutoCAD SHX Text

MOHAWK

AutoCAD SHX Text M58756

AutoCAD SHX Text

12 STRAND SINGLEMODE FIBER CABLE, PLENUM RATED -ARMORED

AutoCAD SHX Text

OCC

AutoCAD SHX Text

DZ012TSLX9YP18

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text WALL MOUNT CABINET. SIZE AS PER DETAILS. INCLUDE PLEXIGLAS FRONT DOOR, FAN ASSEMBLY AND 6-POSITION, RACK MOUNTED POWER STRIP. 48" TALL

AutoCAD SHX Text

HOFFMAN

AutoCAD SHX Text

EWMWG482425

AutoCAD SHX Text TELECOMMUNICATIONS GROUND BAR (TGB). 1/4"x4"x10" EQUIPPED WITH INSULATED STAND-OFFS.

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

HBBB14210A

AutoCAD SHX Text

SINGLE RACK UNIT PATCH CORD ORGANIZER (PCO-1) WITH HINGED COVER.

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

HS13C

AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR JACKS TO MATCH THE CABLE COLOR AND CABLE TYPE BEING TERMINATED. PROVIDE ONE MODULAR JACK FOR EACH CABLE BEING TERMINATED. SEE SPEC AND DRAWINGS FOR COLORS. EQUIP WITH REAR CABLE ORGANIZER

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

PANEL:HPJ24 ORGANIZER:HPRCMB

AutoCAD SHX Text RACK MOUNT FIBER PANEL. USE WHEN TERMINATING 24 OR LESS FIBER STRANDS. PROVIDE EACH FIBER PANEL WITH "SC" SIX OR 12 PACKS AS REQUIRED FOR TERMINATION OF ALL FIBERS. PROVIDE SPLICE TRAY AND SHELF FOR FUSION SPLICES TO PIGTAILS.

AutoCAD SHX Text

HUBBELL

AutoCAD SHX Text

FPR3SP

AutoCAD SHX Text FIBER OPTIC CABLE STOWAGE RING. WALL MOUNTED. 12" OR 24". PROVIDE AND INSTALL TO SUPPORT BEND RADIUS REQUIREMENTS OF THE FIBER CABLE`

AutoCAD SHX Text

LEVITON

AutoCAD SHX Text

12" #48900-IFR / 24" #48900-OFR

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text D

AutoCAD SHX Text F

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text B

AutoCAD SHX Text

GROUND BAR BY E.C.

AutoCAD SHX Text

TYPICAL CRIMP LUG CONNECTIVITY

AutoCAD SHX Text GROUNDING NOTES: 1. CONNECTIONS TO ALL COMMUNICATIONS CONNECTIONS TO ALL COMMUNICATIONS EQUIPMENT & PANELS. 2. CONNECT GROUND BAR TO ALL ITEMS SHOWN CONNECT GROUND BAR TO ALL ITEMS SHOWN & AS DIRECTED IN THE GROUNDING SPECIFICATIONS. 3. ALL GROUND CONNECTIONS SHALL BE MADE ALL GROUND CONNECTIONS SHALL BE MADE WITH CRIMP LUGS ONLY. THIS APPLIES TO ALL CONNECTIONS TO THE GROUND BAR & THE CONNECTIONS TO THE ASSOCIATED EQUIPMENT. 4. GROUND CONNECTIONS SHALL BE MADE WITH A GROUND CONNECTIONS SHALL BE MADE WITH A MINIMUM OF #6 AWG CABLE. 5. ALL CONNECTIONS TO THE GROUND BAR SHALL ALL CONNECTIONS TO THE GROUND BAR SHALL BE MADE WITH PHOSPHER BRONZE BOLTS & NUTS. 6. ALL GROUND WIRES SHALL HAVE GREEN ALL GROUND WIRES SHALL HAVE GREEN INSULATION UNLESS INSTALLED IN A PLENUM AREA. GROUND CABLES THAT MUST BE INSTALLED IN A PLENUM AREA SHALL BE BARE COPPER WIRE WITH GREEN TAPE AT ENDS.

AutoCAD SHX Text

TELECOMM GROUND BAR

AutoCAD SHX Text

BUILDING STEEL, BY EC

AutoCAD SHX Text

LOCAL RECEPT. PANEL, BY EC

AutoCAD SHX Text MAIN DIST. PANEl, BY EC

AutoCAD SHX Text

#6 AWG

AutoCAD SHX Text

DATA NETWORK

AutoCAD SHX Text

AUDIO VIDEO SYSTEMS

AutoCAD SHX Text

COMMUNICATIONS CABINETS/RACKS

AutoCAD SHX Text

TELEPHONE SYSTEM

AutoCAD SHX Text

PAGING/AUDIO SYSTEM

AutoCAD SHX Text

PROTECTED ENTRANCE TERMINAL

AutoCAD SHX Text

#6 AWG

AutoCAD SHX Text

#6 AWG

AutoCAD SHX Text

#6 AWG

AutoCAD SHX Text

#6 AWG

AutoCAD SHX Text

#6 AWG

AutoCAD SHX Text

#6 AWG

AutoCAD SHX Text

TYPICAL FOR ALL GROUND BARS

AutoCAD SHX Text

TECHNOLOGY LEGENDS

AutoCAD SHX Text

SCHEDUILES & DETAILS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TC101

AutoCAD SHX Text

6581 BELDING RD. NE STE. 101

AutoCAD SHX Text

ROCKFORD, MICHIGAN 49341

AutoCAD SHX Text

WWW.COMMTECHDESIGN.COM

AutoCAD SHX Text Design

AutoCAD SHX Text

REGISTRATION SEAL

AutoCAD SHX Text

ISSUE DATES

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text A R C H I T E C T U R E

AutoCAD SHX Text

1191 WEST SQUARE LAKE ROAD

AutoCAD SHX Text

AutoCAD SHX Text

EM INFO TMP-ARCHITECTURE.COM

AutoCAD SHX Text

PH 248.338.4561 FX 248.338.0223

AutoCAD SHX Text

BLOOMFIELD HILLS MICHIGAN 48302

AutoCAD SHX Text

CONSULTANT

AutoCAD SHX Text

ISSUED FOR:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text 02-06-26

AutoCAD SHX Text

CONSTRUCTION DOCUMENTS

AutoCAD SHX Text T M P A R C H I T E C T U R E I N C

AutoCAD SHX Text

WYLIE

AutoCAD SHX Text

ELEMENTARY

AutoCAD SHX Text

CLASSROOM

AutoCAD SHX Text

ADDITION

AutoCAD SHX Text Dexter Community

AutoCAD SHX Text School District

AutoCAD SHX Text

JMS

AutoCAD SHX Text

BVH

AutoCAD SHX Text

BWE

AutoCAD SHX Text 25023D

TC102

CONNECTIVITY CODE

N

TC102

CONNECTIVITY CODE

MOHAWK NOTE

TC102

CONNECTIVITY CODE

TC102

CONNECTIVITY CODE8

TC102

CONNECTIVITY CODE

TC102

CONNECTIVITY CODE9

TC102

CONNECTIVITY CODE

TC102

CONNECTIVITY CODE

TC102

CONNECTIVITY CODE12:08 AM

THU

MAR

TC102

CONNECTIVITY CODE

Commtech

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 FACEPLATE HUBBELL IMF1OW FACEPLATE HUBBELL IMF1OW HUBBELL IMF1OW IMF1OW 2 CAT-6 CABLES MOHAWK M58281 CAT-6 CABLES MOHAWK M58281 MOHAWK M58281 M58281 2 CAT-6 JACK HUBBELL HXJ6OW CAT-6 JACK HUBBELL HXJ6OW HUBBELL HXJ6OW HXJ6OW 1 TWO-HOLE KEYSTONE HUBBELL IM2K1OW TWO-HOLE KEYSTONE HUBBELL IM2K1OW HUBBELL IM2K1OW IM2K1OW 2 1 UNIT BLANK HUBBELL IMB1OW1 UNIT BLANK HUBBELL IMB1OWHUBBELL IMB1OWIMB1OW

AutoCAD SHX Text

COMMUNICATION CABLES

AutoCAD SHX Text

WALL

AutoCAD SHX Text

FACEPLATE

AutoCAD SHX Text ±18"

AutoCAD SHX Text A.F.F.

AutoCAD SHX Text INSTALLATION NOTES: 1. REFER TO THESE NOTES FOR ALL CONNECTIVITY CODES. REFER TO THESE NOTES FOR ALL CONNECTIVITY CODES. FOR SPECIALIZED NOTES SEE THE ACTUAL CONNECTIVITY CODE. 2. ROUTE ALL USER CABLES FROM THE RACK OR CABINET, ROUTE ALL USER CABLES FROM THE RACK OR CABINET, THROUGH THE CABLE TRAY IF SO PROVIDED. IF NO CABLE TRAY IS SHOWN INSTALL CABLES THROUGH "J" HOOKS. PROVIDE ALL "J" HOOKS. 3. CABLES SHALL BE SUPPORTED NO LESS THAN EVERY 5 CABLES SHALL BE SUPPORTED NO LESS THAN EVERY 5 FEET. 4. PROVIDE A SMALL LOOP OF CABLE ABOVE THE CEILING PROVIDE A SMALL LOOP OF CABLE ABOVE THE CEILING PRIOR TO INSTALLING THE CABLE INTO THE USER CONDUIT OR RACEWAY. 5. ROUTE THE CABLE THROUGH THE CONDUIT OR RACEWAY AND ROUTE THE CABLE THROUGH THE CONDUIT OR RACEWAY AND TO THE WALLBOX, FLOORBOX OR SURFACE MOUNT BOX. PROVIDE ENOUGH EXTRA CABLE FOR TERMINATION AND MAINTENANCE. 6. TERMINATE ALL CABLES WITH THE CORRECT CONNECTORS. TERMINATE ALL CABLES WITH THE CORRECT CONNECTORS. 7. ALL CONNECTORS SHALL BE INSERTED INTO THE KEYSTONE ALL CONNECTORS SHALL BE INSERTED INTO THE KEYSTONE PLATES AND THEN THE KEYSTONE PLATES SHALL BE INSTALLED INTO THE FACEPLATES. 8. INSTALL FACEPLATES TO THE BOXES OR DIRECTLY TO THE INSTALL FACEPLATES TO THE BOXES OR DIRECTLY TO THE WALL OR FURNITURE IN THE CASE OF SURFACE MOUNT BOXES. 9. EACH CABLE SHALL HAVE A LASER-PRINTED, EACH CABLE SHALL HAVE A LASER-PRINTED, SELF-LAMINATING WRAP-AROUND LABEL AT EACH END. SEE DETAILS ON TC101 10. OUTLETS SHALL BE AT 18" AFF UNLESS NOTED ON THE OUTLETS SHALL BE AT 18" AFF UNLESS NOTED ON THE CONNECTIVITY CODE OR PLAN DRAWINGS. 11. LABEL EACH FACEPLATE WITH A LASER-PRINTED LABEL LABEL EACH FACEPLATE WITH A LASER-PRINTED LABEL THAT IS INSTALLED BEHIND THE CLEAR PLASTIC LABEL STRIP. WHERE NO LABEL STRIP IS PROVIDED, THE CONTRACTOR SHALL INSTALL A LASER PRINTED ADHESIVE LABEL. WHERE SPECIFICALLY NOTED, THE CONTRACTOR SHALL INSTALL ENGRAVED LAMACOID LABELS. 12. AFTER INSTALLATION, ALL CABLES SHALL BE TESTED. SEE AFTER INSTALLATION, ALL CABLES SHALL BE TESTED. SEE SPECIFICATIONS FOR TESTING REQUIREMENTS. 13. SEE DRAWINGS AND SPECS FOR DETAILS ON LABELING SEE DRAWINGS AND SPECS FOR DETAILS ON LABELING PLATES AND PANELS IN THE COMM ROOMS 14. PROVIDE FLEXIBLE CONDUIT FROM THE WALLBOX OR PROVIDE FLEXIBLE CONDUIT FROM THE WALLBOX OR FLOORBOX TO THE FURNITURE RACEWAY WHERE CABLES ARE INSTALLED IN FURNITURE.

AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE NEAR THE SECURITY CAMERA LOCATION. 2. SEE FLOORPLAN FOR LOCATION. SEE FLOORPLAN FOR LOCATION. 3. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR TYPESEE ARCHITECTURAL REFLECTED CEILING PLAN FOR TYPE

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6 CABLES-GREEN MOHAWK M58286 CAT-6 CABLES-GREEN MOHAWK M58286 MOHAWK M58286 M58286 1 CAT-6 JACK HUBBELL HXJ6GNCAT-6 JACK HUBBELL HXJ6GNHUBBELL HXJ6GNHXJ6GN

AutoCAD SHX Text

PENDANT CAMERA

AutoCAD SHX Text

CAMERA

AutoCAD SHX Text

CAT-6 PATCH BY OTHERS

AutoCAD SHX Text

15' COIL OF CABLE

AutoCAD SHX Text

CAT-6 CABLE

AutoCAD SHX Text

OPEN CEILING INSTALLATION

AutoCAD SHX Text

SECURITY CAMERA -CEILING MOUNTED

AutoCAD SHX Text

ABOVE DROP CEILING INSTALLATION

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

DATA

AutoCAD SHX Text

DATA

AutoCAD SHX Text

BLANK

AutoCAD SHX Text

BLANK

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

SEE TRXXX DRAWINGS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

15' COIL OF CABLE

AutoCAD SHX Text

CAT-6 SURFACE BOX

AutoCAD SHX Text

SURFACE MOUNTED CAMERA

AutoCAD SHX Text

CAT-6 SURFACE BOX

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6A CABLES-YELLOW MOHAWK M59148 CAT-6A CABLES-YELLOW MOHAWK M59148 MOHAWK M59148 M59148 1 CAT-6A JACK HUBBELL HJ6AYCAT-6A JACK HUBBELL HJ6AYHUBBELL HJ6AYHJ6AY

AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE NEAR THE ACCESS POINT LOCATION. 2. INSTALL A LASER PRINTED CABLE LABEL ON THE CEILING WHERE INSTALL A LASER PRINTED CABLE LABEL ON THE CEILING WHERE THE CABLE TERMINATES. THIS WILL ALLOW THE FUTURE USER TO FIND THE CABLE TO EVENTUALLY INSTALL WIRELESS ACCESS POINT.

AutoCAD SHX Text

15' COIL OF CABLE

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

INSTALL YELLOW STICKER DOT ON CEILING GRID

AutoCAD SHX Text

WAP AND PATCH CABLE BY OTHERS

AutoCAD SHX Text

15' COIL OF CABLE

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

WAP AND PATCH CABLE BY OTHERS

AutoCAD SHX Text

WIRELESS ACCESS POINT, CAT-6A

AutoCAD SHX Text

OPEN CEILING INSTALLATION

AutoCAD SHX Text

ABOVE DROP CEILING INSTALLATION

AutoCAD SHX Text

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

LABEL

AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BACKBOX AT THE PROVIDE A SURFACE MOUNT BOX TO THE BACKBOX AT THE SECURITY CAMERA LOCATION. 2. SEE FLOORPLAN FOR INSTALLATION LOCATION. SEE TR SEE FLOORPLAN FOR INSTALLATION LOCATION. SEE TR RACEWAY DRAWINGS FOR HEIGHT OF CAMERA AND CABLING.

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6 CABLES-GREEN MOHAWK M58286 CAT-6 CABLES-GREEN MOHAWK M58286 MOHAWK M58286 M58286 1 CAT-6 JACK HUBBELL HXJ6GNCAT-6 JACK HUBBELL HXJ6GNHUBBELL HXJ6GNHXJ6GN

AutoCAD SHX Text

SECURITY CAMERA-WALL MOUNTED. INDOOR OR OUTDOOR

AutoCAD SHX Text

AutoCAD SHX Text

SEE TRXXX DRAWINGS FOR HEIGHT AND CAMERA FLOORPLANS LOCATION OF BOX

AutoCAD SHX Text

COMMUNICATION CABLE, 15' COIL

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

COMMUNICATION CABLE

AutoCAD SHX Text

WIRELESS ACCESS POINT

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

CAT-6 PATCH CABLE

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6A CABLES-YELLOW MOHAWK M59148 CAT-6A CABLES-YELLOW MOHAWK M59148 MOHAWK M59148 M59148 1 CAT-6 JACK HUBBELL HXJ6YCAT-6 JACK HUBBELL HXJ6YHUBBELL HXJ6YHXJ6Y

AutoCAD SHX Text

SEE TRXXX DRAWINGS

AutoCAD SHX Text

AutoCAD SHX Text

WIRELESS ACCESS POINT, CAT-6 WALL -MOUNTED

AutoCAD SHX Text

INDOOR TYPICAL

AutoCAD SHX Text

OUTDOOR TYPICAL

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6 CABLES MOHAWK M58281 CAT-6 CABLES MOHAWK M58281 MOHAWK M58281 M58281 1 CAT-6 JACK HUBBELL HXJ6OWCAT-6 JACK HUBBELL HXJ6OWHUBBELL HXJ6OWHXJ6OW

AutoCAD SHX Text

LCD DISPLAY

AutoCAD SHX Text

CONCRETE FLOOR

AutoCAD SHX Text

POWER CONDUIT

AutoCAD SHX Text

SEE TRXXX DRAWINGS

AutoCAD SHX Text

AutoCAD SHX Text

COMMUNICATION CABLE

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text INSTALLATION NOTES: 1. LABEL CABLE AND SURFACE BOX WITH CABLE NUMBER LABEL CABLE AND SURFACE BOX WITH CABLE NUMBER 2. COIL DATA CABLE AND MOUNT SURFACE MOUNT BOX TO SIDE COIL DATA CABLE AND MOUNT SURFACE MOUNT BOX TO SIDE OF THE IN-WALL BACKBOX.

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

WALL

AutoCAD SHX Text

FACEPLATE

AutoCAD SHX Text 46" A.F.F.

AutoCAD SHX Text

SEE TRXXX DRAWINGS

AutoCAD SHX Text

COMMUNICATION CABLES

AutoCAD SHX Text

DATA

AutoCAD SHX Text

LABEL

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 CAT-6 CABLE MOHAWK M58281 CAT-6 CABLE MOHAWK M58281 MOHAWK M58281 M58281 1 CAT-6 JACK HUBBELL HXJ6OW CAT-6 JACK HUBBELL HXJ6OW HUBBELL HXJ6OW HXJ6OW 1 TELEPHONE PLATE HUBBELL SP6FTELEPHONE PLATE HUBBELL SP6FHUBBELL SP6FSP6F

AutoCAD SHX Text

AutoCAD SHX Text 96" A.F.F.

AutoCAD SHX Text

OR AS NOTED ON FLOOR PLAN

AutoCAD SHX Text

SINGLE SIDED CLOCK

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

CAT-6 PATCH CABLE

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6 CABLE-BROWN MOHAWK M58786 CAT-6 CABLE-BROWN MOHAWK M58786 MOHAWK M58786 M58786 1 CAT-6 JACK-BROWN HUBBELL HXJ6BN CAT-6 JACK-BROWN HUBBELL HXJ6BN HUBBELL HXJ6BN HXJ6BN 1 IP CLOCK ATLASIED IP-SDMFIP CLOCK ATLASIED IP-SDMFATLASIED IP-SDMFIP-SDMF

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

AutoCAD SHX Text

CLOCK/SPEAKER

AutoCAD SHX Text

COMMUNICATION CABLE

AutoCAD SHX Text

SEE TRXXX DRAWINGS

AutoCAD SHX Text

DUAL SIDED CLOCK

AutoCAD SHX Text 96" A.F.F.

AutoCAD SHX Text

OR AS NOTED ON FLOOR PLAN

AutoCAD SHX Text

LABEL

AutoCAD SHX Text

CAT-6 PATCH CABLE

AutoCAD SHX Text

WALL MOUNTED DUAL SIDED CLOCK

AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6 CABLE-BROWN MOHAWK M58786 CAT-6 CABLE-BROWN MOHAWK M58786 MOHAWK M58786 M58786 1 CAT-6 JACK-BROWN HUBBELL HXJ6BN CAT-6 JACK-BROWN HUBBELL HXJ6BN HUBBELL HXJ6BN HXJ6BN 1 IP CLOCK ATLASIED IP-DDIP CLOCK ATLASIED IP-DDATLASIED IP-DDIP-DD

AutoCAD SHX Text

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

SEE TRXXX DRAWINGS

AutoCAD SHX Text

CABLING CONNECTIVITY

AutoCAD SHX Text

CODES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TC102

AutoCAD SHX Text

6581 BELDING RD. NE STE. 101

AutoCAD SHX Text

ROCKFORD, MICHIGAN 49341

AutoCAD SHX Text

WWW.COMMTECHDESIGN.COM

AutoCAD SHX Text Design

AutoCAD SHX Text

REGISTRATION SEAL

AutoCAD SHX Text

ISSUE DATES

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text A R C H I T E C T U R E

AutoCAD SHX Text

1191 WEST SQUARE LAKE ROAD

AutoCAD SHX Text

AutoCAD SHX Text

EM INFO TMP-ARCHITECTURE.COM

AutoCAD SHX Text

PH 248.338.4561 FX 248.338.0223

AutoCAD SHX Text

BLOOMFIELD HILLS MICHIGAN 48302

AutoCAD SHX Text

CONSULTANT

AutoCAD SHX Text

ISSUED FOR:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text 02-06-26

AutoCAD SHX Text

CONSTRUCTION DOCUMENTS

AutoCAD SHX Text T M P A R C H I T E C T U R E I N C

AutoCAD SHX Text

WYLIE

AutoCAD SHX Text

ELEMENTARY

AutoCAD SHX Text

CLASSROOM

AutoCAD SHX Text

ADDITION

AutoCAD SHX Text Dexter Community

AutoCAD SHX Text School District

AutoCAD SHX Text

JMS

AutoCAD SHX Text

BVH

AutoCAD SHX Text

BWE

TC103

BUILDING FIBER

BACKBONE CONNECTIVITY

TC103

COMM ROOM "IDF-4"

RACK LAYOUTS

TC103

CABLE INSTALLATION AND SUPPORT

TYPES OF SUPPORT THAT ARE DISALLOWED

TC103

DATA CABLE

SUPPORT DETAILS AND REQUIREMENTS

TC103

DATA CABLE

DROP CEILING CABLE SUPPPORT. TYPICAL

TC103

FIBER OPTIC CABLE

LABELING

TC103

FIBER OPTIC PANEL

LABELING DETAIL

TC103

AUDIO PAGING AND CLOCK SYSTEM

NETWORK ATTACHED. SYSTEM DIAGRAM

12:08 AM

THU

MAR

IP PAGING CLOCK/SPEAKER EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

ANALOG PAGING SPEAKER EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

12:08 AM

THU

MAR

Commtech

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text KEYED NOTES: INSTALL FIBER OPTIC RINGS ON THE WALL OF THE COMM ROOM. PROVIDE A SPARE 30' COIL OF CABLE. INSTALL FIBER CABLES THROUGH THE CONDUITS BETWEEN BUILDINGS. WHEN INSTALLING THE FIBER INSIDE THE BUILDING ENSURE IT IS ROUTED INSIDE CONDUIT. SEE ELECTRICAL PLANS FOR CONDUIT LOCATIONS SEE RACK LAYOUTS FOR FIBER PANEL PARTS.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text KEYED NOTES: CONTRACTOR SHALL INSTALL 12" CABLE LADDER VERTICALLY FROM TOP OF CABINET OR RACK TO THE CEILING AREA FOR ROUTING USER CABLES TO THE PANELS.

AutoCAD SHX Text

AutoCAD SHX Text 12"

AutoCAD SHX Text GENERAL NOTES: 1. CABINETS SHALL BE INSTALLED DIRECTLY TO THE WALL CABINETS SHALL BE INSTALLED DIRECTLY TO THE WALL AND PROPERLY SECURED. INSTALL PLYWOOD ON THE WALL PRIOR TO INSTALLING THE CABINET IF THE CABINET IS MOUNTED ON STUD TYPE WALL. 2. WALL MOUNTED CABINETS SHALL BE MOUNTED TO WALL WALL MOUNTED CABINETS SHALL BE MOUNTED TO WALL SO TOP OF RACK IS NO HIGHER THAN 7' AFF. 3. INSTALL THE BACKBONE CABLES THAT ROUTE BETWEEN INSTALL THE BACKBONE CABLES THAT ROUTE BETWEEN COMMUNICATIONS ROOMS. COIL SPARE FIBER CABLE ON THE WALL. ROUTE CABLES TO THE RACK/CABINET VIA CABLE LADDER. 4. ALL USER DATA CABLES SHALL ROUTE IN THE CEILING & ALL USER DATA CABLES SHALL ROUTE IN THE CEILING & THEN ROUTE D0WN VERTICAL CABLE LADDER TO THE CABINET. IN THE CABINET, PROVIDE A "DRIP LOOP" FOR ALL THE CABLES DRIP LOOP SHALL BE A MINIMUM OF ONE FOOT. 5. ROUTE CABLES ALONG THE HINGE SIDE OF THE CABINET. ROUTE CABLES ALONG THE HINGE SIDE OF THE CABINET. 6. CONNECT ALL RACKS, CABINETS AND CABLE LADDER TO CONNECT ALL RACKS, CABINETS AND CABLE LADDER TO THE GROUND BAR AS DESCRIBED IN THE GROUNDING DETAIL DETAIL & THE GROUNDING SPECIFICATIONS.

AutoCAD SHX Text

AutoCAD SHX Text

WYLIE COMM ROOM MDF

AutoCAD SHX Text

WYLIE IDF-4

AutoCAD SHX Text

FIBER PANEL IN RACK

AutoCAD SHX Text

NOTE 3

AutoCAD SHX Text

4'X8'X3/4" PLYWOOD

AutoCAD SHX Text

WALLFIELD "A"

AutoCAD SHX Text

GROUND BAR

AutoCAD SHX Text

48 PORT ENET SWITCH

AutoCAD SHX Text

FIBER OPTIC PANEL

AutoCAD SHX Text

PCO - 1

AutoCAD SHX Text

48 PORT ENET SWITCH

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text

CAT-6, 24 PORT

AutoCAD SHX Text

CAT-6, 24 PORT

AutoCAD SHX Text D

AutoCAD SHX Text

CAT-6, CAMS/WIRELESS

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text WALLFIELD NOTES: A. PLYWOOD SHALL BE INSTALLED ON THE WALL SHOWN IN PLYWOOD SHALL BE INSTALLED ON THE WALL SHOWN IN THE COMMUNICATIONS ROOM FLOOR PLAN AND AS DETAILED IN THIS DRAWING. B. VERTICAL PLYWOOD SHALL BE MOUNTED AT 12" AFF TO VERTICAL PLYWOOD SHALL BE MOUNTED AT 12" AFF TO THE BOTTOM OF THE PLYWOOD. C. PLYWOOD SHALL BE FIRE RESISTANT PLYWOOD. GRADE "A" PLYWOOD SHALL BE FIRE RESISTANT PLYWOOD. GRADE "A" ON THE SIDE TOWARDS THE USER. D. PLYWOOD SHALL BE PAINTED WITH WHITE PAINT. LEAVE PLYWOOD SHALL BE PAINTED WITH WHITE PAINT. LEAVE ONE OF THE FIRE RESISTANT STAMPS VISIBLE. DO NOT PAINT OVER THE STAMP. E. THE CONTRACTOR SHALL INSTALL D-RINGS OR CABLE THE CONTRACTOR SHALL INSTALL D-RINGS OR CABLE LADDER TO ROUTE CABLES HORIZONTALLY & VERTICALLY ALONG THE WALLFIELD.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WYLIE COMM ROOM IDF-4 NEW WALL CABINET IDF-4-1

AutoCAD SHX Text

CABLES SHALL NOT REST ON HVAC DUCT

AutoCAD SHX Text

HVAC DUCT

AutoCAD SHX Text CABLES SHALL NOT BE ATTACHED OR REST DIRECTLY TO THREADED ROD OR OTHER ONTO PIPES

AutoCAD SHX Text DO NOT USE TY-WRAPS OR VELCRO TO ATTACH CABLES TO BUILDING STRUCTURE OR OTHER SUPPORTS

AutoCAD SHX Text

CABLES SHALL NOT REST ON CONDUIT NOR BE ATTACHED TO CONDUIT

AutoCAD SHX Text

CABLES SHALL NOT BE ATTACHED OR REST DIRECTLY TO BUILDING STEEL

AutoCAD SHX Text

CABLES SHALL NOT BE INSTALLED IN BETWEEN BUILDING STEEL AND ROOF

AutoCAD SHX Text

CABLES SHALL NOT BE INSTALLED THRU A WALL WITHOUT A CONDUIT PASS-THRU

AutoCAD SHX Text INSTALLATION NOTES: 1. CONTRACTOR SHALL INSTALL CABLES AROUND THE BUILDING AND CONTRACTOR SHALL INSTALL CABLES AROUND THE BUILDING AND SHALL SUPPORT CABLES AS PER NOTES, DETAILS AND INDUSTRY STANDARDS. 2. DO NOT USE ANY TY-WRAPS OR TAPE TO SUPPORT CABLES. DO NOT USE ANY TY-WRAPS OR TAPE TO SUPPORT CABLES. 3. DO NOT ATTACH CABLES TO BUILDING STEEL, CONDUITS OR PIPES. DO NOT ATTACH CABLES TO BUILDING STEEL, CONDUITS OR PIPES. 4. DO NOT INSTALL CONDUITS THRU A WALL WITHOUT INSTALLING DO NOT INSTALL CONDUITS THRU A WALL WITHOUT INSTALLING NYLON GROMMETS TO THE END OF THE CONDUIT PASS THRUS. 5. DO NOT ALLOW CABLES TO REST ON HVAC DUCTS.DO NOT ALLOW CABLES TO REST ON HVAC DUCTS.

AutoCAD SHX Text INSTALLATION NOTES: 1. CONTRACTOR SHALL INSTALL CABLE SUPPORTS TO ENSURE CABLES CONTRACTOR SHALL INSTALL CABLE SUPPORTS TO ENSURE CABLES ARE NOT LAYING ON CONDUIT, WATERPIPE OR BUILDING STEEL. 2. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUCH AS J-HOOKS CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUCH AS J-HOOKS AND BRIDLE RINGS TO SUPPORT CABLE EVERY 5' MINIMUM 3. WHEN ROUTING CABLES ALONG A WALL, ABOVE A CEILING OR WHEN ROUTING CABLES ALONG A WALL, ABOVE A CEILING OR ABOVE 12' AFF, INSTALL J-HOOKS ON WALL EVERY 5' MINIMUM OR AS REQUIRED TO KEEP CABLES FROM RESTING ON CEILING. 4. THERE SHALL BE ABSOLUTELY NO USE OF TAPE OR TY-WRAPS ON THERE SHALL BE ABSOLUTELY NO USE OF TAPE OR TY-WRAPS ON THE CABLES. USE ONLY VELCRO STRAPS ON CABLE. DO NOT SUPPORT CABLE DIRECTLY TO CONDUITS, PIPES OR BUILDING STEEL. 5. DO NOT USE DROP CEILING TILE WIRES TO SUPPORT CABLES. DO NOT USE DROP CEILING TILE WIRES TO SUPPORT CABLES. WHERE NO BUILDING STEEL OR WALL IS AVAILABLE INSTALL DROP CEILING WIRES AND ANCHORT TO BUILDING STEEL OR DIRECTLY INTO CONCRETE CEILING. 6. INSTALL CABLE SUPPORTS DIRECTLY ABOVE THE CAMERA OR WAP INSTALL CABLE SUPPORTS DIRECTLY ABOVE THE CAMERA OR WAP LOCATION. COIL CABLE AND SUPPORT ON A J-HOOK OR BRIDLE RING. USE VELCRO TO SECURE LOOP TO THE CABLE SUPPORT.

AutoCAD SHX Text

COIL OF CABLE

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

INSTALL GREEN OR YELLOW STICKER DOT ON CEILING GRID

AutoCAD SHX Text DROP CEILING INSTALLATION WHERE THERE IS BUILDING STEEL WITHIN 24" OF DROP CEILING

AutoCAD SHX Text

J-HOOKS -TYP

AutoCAD SHX Text

COIL OF CABLE

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

INSTALL GREEN OR YELLOW STICKER DOT ON CEILING GRID

AutoCAD SHX Text DROP CEILING INSTALLATION WHERE THERE IS BUILDING STEEL MOPE THAN 24" OF DROP CEILING

AutoCAD SHX Text

J-HOOKS -TYP

AutoCAD SHX Text

ATTACH J-HOOKS TO BLDG STEEL. CAN BE AT TOP, IN MIDDLE OR AT BOTTOM OF STEEL

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

INSTALL CABLING ALONG WALL. OPEN CEILING ABOVE 12' OR ABOVE ACCESSIBLE CEILING

AutoCAD SHX Text

J-HOOKS -TYP

AutoCAD SHX Text ATTACH J-HOOKS TO THE WALL. INSTALL MINIMUM EVERY 5' AND AS CLOSE TO KEEP CABLES FROM CEILING

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

INSTALL GREEN OR YELLOW STICKER DOT ON CEILING GRID

AutoCAD SHX Text

INSTALL CABLING WITH SUPPORT FROM THE CEILING

AutoCAD SHX Text

J-HOOKS -TYP

AutoCAD SHX Text ATTACH J-HOOKS TO THE WALL. INSTALL MINIMUM EVERY 5' AND AS CLOSE TO KEEP CABLES FROM CEILING

AutoCAD SHX Text

THREADED ROD OR 12 GA WIRE -TYP

AutoCAD SHX Text

SIDE VIEW

AutoCAD SHX Text = TIE WRAPS OR VELCRO IS NOT TO BE TIE WRAPS OR VELCRO IS NOT TO BE USED FOR DIRECT SUPPORT OF CABLES TO PIPES, STEEL OR BUILDING STRUCTURE

AutoCAD SHX Text

ROUTING CABLES DIRECTLY THRU A WALL IS NOT ALLOWED. CONDUIT MUST BE INSTALLED

AutoCAD SHX Text

SIDE VIEW

AutoCAD SHX Text

FRONT VIEW

AutoCAD SHX Text

CABLE

AutoCAD SHX Text

STEEL

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

CONDUIT

AutoCAD SHX Text

SURFACE BOX

AutoCAD SHX Text

INSTALL GREEN OR YELLOW STICKER DOT ON CEILING GRID

AutoCAD SHX Text

INSTALL CABLING WITH SUPPORT FROM THE CEILING

AutoCAD SHX Text

J-HOOKS -TYP

AutoCAD SHX Text ATTACH J-HOOKS TO THE WALL. INSTALL MINIMUM EVERY 5' AND AS CLOSE TO KEEP CABLES FROM CEILING

AutoCAD SHX Text

CEILING TILE WIRE. PAINTED GREEN. ATTACH TO GRID

AutoCAD SHX Text

THREADED ROD OR 12 GA WIRE -TYP

AutoCAD SHX Text INSTALLATION NOTES: 1. CONTRACTOR SHALL INSTALL CABLE SUPPORTS TO ENSURE CABLES CONTRACTOR SHALL INSTALL CABLE SUPPORTS TO ENSURE CABLES ARE NOT LAYING ON CONDUIT, WATERPIPE OR BUILDING STEEL. 2. CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUCH AS J-HOOKS CONTRACTOR SHALL INSTALL CABLE SUPPORTS SUCH AS J-HOOKS AND BRIDLE RINGS TO SUPPORT CABLE EVERY 5' MINIMUM 3. WHEN ROUTING CABLES ALONG A WALL, ABOVE A CEILING OR WHEN ROUTING CABLES ALONG A WALL, ABOVE A CEILING OR ABOVE 12' AFF, INSTALL J-HOOKS ON WALL EVERY 5' MINIMUM OR AS REQUIRED TO KEEP CABLES FROM RESTING ON CEILING. 4. THERE SHALL BE ABSOLUTELY NO USE OF TAPE OR TY-WRAPS ON THERE SHALL BE ABSOLUTELY NO USE OF TAPE OR TY-WRAPS ON THE CABLES. USE ONLY VELCRO STRAPS ON CABLE. DO NOT SUPPORT CABLE DIRECTLY TO CONDUITS, PIPES OR BUILDING STEEL. 5. DO NOT USE EXISTING DROP CEILING TILE WIRES TO SUPPORT DO NOT USE EXISTING DROP CEILING TILE WIRES TO SUPPORT CABLES. WHERE NO BUILDING STEEL OR WALL IS AVAILABLE INSTALL DROP CEILING WIRES AND ANCHOR TO BUILDING STEEL OR DIRECTLY INTO CONCRETE CEILING. ATTACH TO DROP CEILING GRID. PAINT WIRES GREEN PRIOR TO INSTALLATION. 6. INSTALL CABLE SUPPORTS DIRECTLY ABOVE THE CAMERA OR WAP INSTALL CABLE SUPPORTS DIRECTLY ABOVE THE CAMERA OR WAP LOCATION. COIL CABLE AND SUPPORT ON A J-HOOK OR BRIDLE RING. USE VELCRO TO SECURE LOOP TO THE CABLE SUPPORT.

AutoCAD SHX Text GENERAL NOTES: 1. INSTALL ALL EQUIPMENT SHOWN. THE CONTRACTOR SHALL WALK THE INSTALL ALL EQUIPMENT SHOWN. THE CONTRACTOR SHALL WALK THE BUILDING AND SITE WITH THE OWNER PRIOR TO INSTALLATION TO IDENTIFY ACTUAL LOCATION OF ALL EQUIPMENT. 2. IDENTIFY LOCATION OF ALL FIBER PANELS IN THE RACKS WITH THE OWNER. IDENTIFY LOCATION OF ALL FIBER PANELS IN THE RACKS WITH THE OWNER. PRIMARILY IDENTIFY AT THE TOP OF THE RACKS IN EACH COMM ROOM. LOCATE THE FIBER OPTIC STOWAGE RINGS ON THE WALL WITH THE DESIGNER. 3. ALL CABLES SHALL HAVE A WRAP-AROUND LABEL AT THE TERMINATION TO ALL CABLES SHALL HAVE A WRAP-AROUND LABEL AT THE TERMINATION TO IDENTIFY THE CABLE AT EACH END. INSTALL AT COIL ON WALL AND WHERE THE FIBER ENTERS THE FIBER OPTIC PANEL 4. TEST ALL FIBER CABLES FOR LOSS. PROVIDE REPORTS.TEST ALL FIBER CABLES FOR LOSS. PROVIDE REPORTS.

AutoCAD SHX Text

FIBER PANEL IN RACK

AutoCAD SHX Text

AutoCAD SHX Text

RACK MOUNTED FIBER PANEL

AutoCAD SHX Text

12 STRAND, 50 MICRON TO COMM RM. TR-1 #1237 XXX-YYY/XXX-YYY ZZAA

AutoCAD SHX Text

AutoCAD SHX Text

LAMINATED LABEL DETAILING FIBER CABLES IN THE STOWAGE RING -TYPICAL

AutoCAD SHX Text

AutoCAD SHX Text

WRAP-AROUND LABEL

AutoCAD SHX Text

AutoCAD SHX Text

STOWAGE RING ON WALL OF COMM ROOM

AutoCAD SHX Text KEYED NOTES: PROVIDE ADHESIVE LABEL ON FRONT OF EACH FIBER PANEL FOR LABELING THE FIBER CABLES INSTALL SELF-LAMINATING, WRAP-AROUND LABELS AT FIBER PANEL AND STOWAGE RING.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text XXX-YYY/XXX-YYY ZZAA WRAP-AROUND LABEL XXX = CABINET OR BUILDING. CAB/ADM IN EXAMPLE YYY = CABINET NUMBER OR BUILDING ROOM # ZZ = FIBER STRAND COUNT AA = MULTIMODE MM OR SINGLEMODE SM

AutoCAD SHX Text

CAB-001 / CAB-002 12-SM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text NOTES 1. THE FIBER PANELS AT THE RACK AND AT THE EXTERIOR CABINETS SHALL BE LABELED TO IDENTIFY THE FIBER. 2. LABELS IDENTIFYING THE FIBER CABLES SHALL BE ENGRAVED LABELS WITH BLACK BACKGROUND AND WHITE LETTERS. 3. SIZE THE LABELS TO MATCH THE SIZE OF THE PANEL. PROVIDE A SAMPLE TO THE OWNER AND ENGINEER PRIOR TO PURCHASING. 4. PROVIDE A WRAP-AROUND LABEL ON THE FIBER CABLE AS IT ENTERS THE PATCH PANEL. LASER PRINTED

AutoCAD SHX Text

ENGRAVED PHENOLIC LABEL (TYP)

AutoCAD SHX Text

ENGRAVED PHENOLIC LABEL

AutoCAD SHX Text

24 STRAND SM FIBER TO CAB-001

AutoCAD SHX Text

THIS IS CABINET CAB-002

AutoCAD SHX Text

24 STRAND SM FIBER TO CAB-003

AutoCAD SHX Text

BLANK

AutoCAD SHX Text

RACK MOUNT FIBER PANEL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BLANK PANEL

AutoCAD SHX Text

ENGRAVED PHENOLIC LABEL (TYP)

AutoCAD SHX Text

WRAP AROUND LABEL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ETHERNET SWITCH (NOT PART OF PAGING SYSTEM BID)

AutoCAD SHX Text

CAT-6

AutoCAD SHX Text

INSTALL CAT-6 PATCH CABLES FOR COMPLETE CONNECTIVITY-TYP

AutoCAD SHX Text

EXISTING PAGING SYSTEM

AutoCAD SHX Text

IN COMM ROOM

AutoCAD SHX Text

EXISTING SINGLEWIRE INFORMACAST SOFTWARE ON OWNERS SERVER

AutoCAD SHX Text NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CABLES CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CABLES ASSOCIATED WITH THE CONNECTIVITY OF THE PAGING/BELL SYSTEM. ALL SHALL BE PLENUM RATED 2. SEE BID SCOPES AND FLOORPLANS FOR WHO IS TO SEE BID SCOPES AND FLOORPLANS FOR WHO IS TO INSTALL THE CAT-6 CABLES FROM COMM ROOM TO ALL IP POE DEVICES. 3. ALL CABLES FOR PAGING SYSTEM SHALL BE GRAY AND ALL CABLES FOR PAGING SYSTEM SHALL BE GRAY AND PLENUM RATED. 4. CONTRACTOR SHALL LABEL EACH PAGING SYSTEM CONTRACTOR SHALL LABEL EACH PAGING SYSTEM SPEAKER CABLE. THE LABEL SHALL BE "ZONE XXX" WHERE XXX DESIGNATES THE EXTENSION THAT THE CABLE IS CONNECTED TO. CABLES SHALL BE LABELED AT EACH TERMINATION POINT & AT EACH PATCH PANEL IN COMM ROOM 5. PROVIDE INTERCONNECTION CABLES AS REQUIRED FOR PROVIDE INTERCONNECTION CABLES AS REQUIRED FOR ZONES AND POWER DISTRIBUTION TO THE SPEAKERS FROM AMPLIFIERS AND FROM CLOCKS. CONTRACTOR SHALL VERIFY CONFIGURATION WITH ENGINEER PRIOR TO INSTALLATION. 6. IDENTIFY EXISTING SPEAKERS TO REMAIN AND EXISTING IDENTIFY EXISTING SPEAKERS TO REMAIN AND EXISTING CABLE THAT ATTACHES TO THOSE SPEAKERS. ATTACH EXISTING CABLE TO IP TO ANALOG INTERFACE. 7. INSTALL A DIRECT TELEPHONE INTERFACE THAT WILL BE INSTALL A DIRECT TELEPHONE INTERFACE THAT WILL BE VIA A SIP TRUNK. CONFIGURE TELEPHONE SYSTEM AND PAGING SYSTEM TO ALLOW FULL CALLING FROM TELEPHONE SYSTEM TO ALL SPEAKERS ZONES. 8. PAGING SYSTEM SHALL HAVE AN INTEGRATED BELL PAGING SYSTEM SHALL HAVE AN INTEGRATED BELL SYSTEM THAT ALLOWS CONFIGURATION OF THE BELLS VIA A PC. OWNER SHALL BE ABLE TO EASILY CHANGE ON A PER-ZONE BASIS. USE IP NETWORK FOR CONNECTION. 9. THE CONTRACTOR SHALL CONSULT WITH THE OWNER THE CONTRACTOR SHALL CONSULT WITH THE OWNER PRIOR TO INSTALLATION. WORK OUT WHICH SPEAKERS WILL BE CONNECTED TO EACH AUDIO ZONE. SUBMIT A CONNECTIVITY DIAGRAM PRIOR TO INSTALLATION. INSTALL ALL CABLES FROM CLOCKS TO CONNECT NEW AND EXISTING SPEAKERS. REFER TO FLOORPLANS FOR NEW AND REMAINING SPEAKERS. 10. THE PAGING SYSTEM SHALL BE CONSTANTLY UPDATED THE PAGING SYSTEM SHALL BE CONSTANTLY UPDATED VIA A NATIONAL TIME CONNECTION TO KEEP THE BELLS THE SAME TIME AS THE CLOCKS. 11. SYSTEM SHALL ALLOW THE USE OF TELEPHONES FOR SYSTEM SHALL ALLOW THE USE OF TELEPHONES FOR PAGES TO BE MADE TO ANY INDIVIDUAL ZONE. THIS SHALL INCLUDE TALKBACK THRU THE TELEPHONE SYSTEM. 12. WORK WITH OWNER PRIOR TO INSTALLATION TO WORK WITH OWNER PRIOR TO INSTALLATION TO DESIGNATE EACH SPEAKER AND ITS ZONE CONNECTION AND NUMBER. 13. PROVIDE FOR TWO-WAY INTEGRATION TO THE EXISTING PROVIDE FOR TWO-WAY INTEGRATION TO THE EXISTING ACCESS CONTROL SYSTEM. 14. CONTACT CLOSURE (CC) OUT OF PACS TO PAGING CONTACT CLOSURE (CC) OUT OF PACS TO PAGING SYSTEM WHEN LOCKDOWN BUTTON IS PUSHED. PAGING SYSTEM THEN TURNS ON BLUE LIGHT ON PAGING SPEAKERS AND SENDS PRE-RECORDED MESSAGE FOR THREE TIMES. CUSTOM RECORD MESSAGE FOR OWNER. 15. EACH CLOCK SHALL SHOW SCROLLING LOCKDOWN EACH CLOCK SHALL SHOW SCROLLING LOCKDOWN MESSAGE AND BLUE FLASHING LIGHT UNTIL LOCKDOWN IS RESET. 16. CONNECT PAGING SYSTEM TO PACS TO INITIATE AN CONNECT PAGING SYSTEM TO PACS TO INITIATE AN ACCESS CONTROL SYSTEM LOCKDOWN WHEN PAGING SYSTEM LOCKDOWN IS PUSHED. THIS LOCKDOWN MAY ORIGINATE IN AN ADMINSTRATOR CELLPHONE THAT HAS THE REVOLUTION SOFWARE APPLICATION. 17. CREATE CUSTOM TONES FOR LOCKDOWN, TORNADO AND CREATE CUSTOM TONES FOR LOCKDOWN, TORNADO AND EVACUATE. 18. CONFIGURE THE AUTOMATIC AUDIO MESSAGES SUCH AS CONFIGURE THE AUTOMATIC AUDIO MESSAGES SUCH AS LOCKDOWN AND TORNADO TO "DUCK" WHEN AN ANNOUNCEMENT IS MADE FROM A TELEPHONE, DESKTOP MICROPHONE OR ADMIN STATION. 19. TORNADO WARNINGS AND SEVERE WEATHER WARNINGS: TORNADO WARNINGS AND SEVERE WEATHER WARNINGS: TRIGGER THIS THRU THE SOFTWARE. TORNADO AND EXTREME WEATHER SAHLL BE CONFIGURED FOR YELLOW LIGHTS AND SPECIFIC TONE TO BE REPEATED FOR AN OWNER SPECIFIED LENGTH OF TIME.

AutoCAD SHX Text

AutoCAD SHX Text KEYED NOTES: WHERE MULTIPLE SPEAKERS ARE REQUIRED TO BE ON THE SAME ZONE. PROVIDE AMPLIFIER AS REQUIRED TO POWER ALL SPEAKERS. EXISTING PAGING SYSTEM IS INSTALLED IN AN EXISTING CABINET OR ON THE WALL IN THE COMMUNICATION ROOMS. COORDINATE WITH THE DISTRICT FOR LOCATIONS. CONNECT TO POWER. LOAD ALL PAGING SYSTEM SOFTWARE ON NO LESS THAN 3 OF THE OWNERS PC'S AT THE BUILDING. SHALL WORK ON A WINDOWS OR APPLE DEVICE.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HALLWAY

AutoCAD SHX Text

OUTSIDE

AutoCAD SHX Text

EXISTING ETHERNET SWITCH

AutoCAD SHX Text

TC

AutoCAD SHX Text

TC

AutoCAD SHX Text

INSTALL SPEAKER CABLES

AutoCAD SHX Text

COMM RM

AutoCAD SHX Text

COMM RM

AutoCAD SHX Text

ETHERNET CONNECTION

AutoCAD SHX Text

ANALOG ZONES DIAGRAM

AutoCAD SHX Text

AutoCAD SHX Text

TA

AutoCAD SHX Text

CAT-6 PATCH PANEL-PAGING

AutoCAD SHX Text

GRAY CAT-6 CABLES

AutoCAD SHX Text DIGITAL IP WALL MOUNTED CLOCK WITH SPEAKER. INCLUDE TALKBACK MIC, FLASHER AND 25/70V SWITCH

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

IP-SDMF

AutoCAD SHX Text

DIGITAL IP WALL MOUNTED CLOCK. INCLUDE FLASHER

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

IP-DD

AutoCAD SHX Text

POE+ TO ANALOG GATEWAY ZONE CONTROLLER WITH AMPLIFIER AND RACK KIT

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

IPZCM1RMK

AutoCAD SHX Text

TB

AutoCAD SHX Text

TA

AutoCAD SHX Text

PAGING SYSTEM SPEAKER. INDOOR/OUTDOOR HORN.

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

GA-30T

AutoCAD SHX Text PAGING SYSTEM SPEAKER FOR DROP CEILING INSTALLATION. EQUIP WITH WHITE GRILL AND MULTI TAPS. PROVIDE T-BAR AND BACKBOX

AutoCAD SHX Text

ATLAS IED

AutoCAD SHX Text

SD72WV

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FIBER OPTIC PANEL IN MDF

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

TC

AutoCAD SHX Text

CAT-6

AutoCAD SHX Text

TB

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text

NOTE 3

AutoCAD SHX Text

ASSUME THIS FIBER IS 400' LONG

AutoCAD SHX Text

CABLING RACK

AutoCAD SHX Text

LAYOUTS & DETAILS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TC103

AutoCAD SHX Text

6581 BELDING RD. NE STE. 101

AutoCAD SHX Text

ROCKFORD, MICHIGAN 49341

AutoCAD SHX Text

WWW.COMMTECHDESIGN.COM

AutoCAD SHX Text Design

AutoCAD SHX Text

REGISTRATION SEAL

AutoCAD SHX Text

ISSUE DATES

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text A R C H I T E C T U R E

AutoCAD SHX Text

1191 WEST SQUARE LAKE ROAD

AutoCAD SHX Text

AutoCAD SHX Text

EM INFO TMP-ARCHITECTURE.COM

AutoCAD SHX Text

PH 248.338.4561 FX 248.338.0223

AutoCAD SHX Text

BLOOMFIELD HILLS MICHIGAN 48302

AutoCAD SHX Text

CONSULTANT

AutoCAD SHX Text

ISSUED FOR:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text 02-06-26

AutoCAD SHX Text

CONSTRUCTION DOCUMENTS

AutoCAD SHX Text T M P A R C H I T E C T U R E I N C

AutoCAD SHX Text

WYLIE

AutoCAD SHX Text

ELEMENTARY

AutoCAD SHX Text

CLASSROOM

AutoCAD SHX Text

ADDITION

AutoCAD SHX Text Dexter Community

AutoCAD SHX Text School District

AutoCAD SHX Text

JMS

AutoCAD SHX Text

BVH

AutoCAD SHX Text

BWE

GENERAL CABLING NOTES

1. COMMUNICATIONS CONTRACTOR SHALL INSTALL ANY

PASS-THRU'S REQUIRED FOR ROUTING CABLES AROUND THE

BUILDING THAT ARE NOT SHOWN AS BEING INSTALLED AS PART

OF THE "TR" SERIES DRAWINGS. SEE ATTACHED.

2. CONTRACTOR SHALL COMPLETE A WALK-THRU OF THE SITE

DURING CONSTRUCTION AND SHALL VERIFY ALL CONDUITS

AND PASS THRU'S ARE INSTALLED FOR CABLES.

3. ALL CABLES SHALL BE SUPPORTED ABOVE THE DROP CEILING

BY J-HOOKS. HOOKS SHALL BE LOCATED NO LESS THAN EVERY

5 FEET.

FEC

FEC

FE

FE

FE

5 5

5 5

5 5

:0

AM55

TH

U

M

AR27

9 9

9 9

1 1

:0

AM55

TH

U

M

AR27

:0

AM55

TH

U

M

AR27

:0

AM55

TH

U

M

AR27

:0

AM 55

TH

U

M

AR 27

:0

AM55

TH

U

M

AR27

:0

AM55

TH

U

M

AR27

12:08

12:08

CORRIDOR

F119 STORAGE

F120

CLASSROOM

F118CLASSROOM

F117

CLASSROOM

F115

CLASSROOM

F116

CLASSROOM

F113

CLASSROOM

F114

CLASSROOM

F111

VESTIBULE

F100

SINKS

F102

TOILET

F103

TOILET

F107

CUSTODIAL

F108

CUSTODIAL

F109

STAFF TOILET

F110

IDF-4 COMM

ROOM

4'X8' WALLFIELDS

IDF4-1 WALL CABINET

SEE DETAIL TC103/1

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

2/2 3/2

6 2

:2 9:

P

M Au to de sk D oc s:

//2

D_

W yli e E S

Cl as sr oo m A dd iti on /25

3D

-T

EC

H-

.rv t

WYLIE

ELEMENTARY

CLASSROOM

ADDITION

FIRST LEVEL CABLING PLAN

UNIT F

25023D

TC201

JMS

BVH

BWE

02-06-2026 CONSTRUCTION DOCUMENTS

02-25-2026 ADDENDUM #1

TC301

TYPICAL CABLE LABELING

FOR AUDIO CABLES

AUDIO VIDEO SYMBOL LEGEND

SYMBOL DESCRIPTION

ABBREVIATIONS

ABBREV. DESCRIPTION ABBREV. DESCRIPTION

FLAT PANEL DISPLAY EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

AUDIO/VIDEO CABLE SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

SPEAKER SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

AUDIO EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

TC301

INTERACTIVE LCD

CLASSROOM AV CONNECTIVITY

TYPICAL FOR LAY-IN CEILING CLASSROOMS

VIDEO EQUIPMENT SCHEDULE

MARK DESCRIPTION MANUFACTURER PART NO.

Commtech

AutoCAD SHX Text %%uBACK OF FACEPLATE

AutoCAD SHX Text

%%UBACK OF EQUIPMENT OR

AutoCAD SHX Text

A-XXXX-YY

AutoCAD SHX Text

WRAP-AROUND LABEL

AutoCAD SHX Text 33-3204-02

AutoCAD SHX Text

WRAP-AROUND LABEL

AutoCAD SHX Text 33-3204-02

AutoCAD SHX Text

%%UAT TERMINAL STRIP

AutoCAD SHX Text

%%UOR AT SPEAKER

AutoCAD SHX Text

A-XXXX-YY

AutoCAD SHX Text GENERAL NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. 2. WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE SELF-LAMINATING.

AutoCAD SHX Text A = AUDIO/VIDEO CABINET XXXX = SPK FOR SPEAKER LINE XXXX = LINE FOR LINE LEVEL XXXX = MIC FOR MICROPHONE XXXX = CTRL FOR CONTROL LINE YY = AUDIO ZONE FOR SPEAKER YY = FACEPLATE NUMBER FOR LINE AND MIC

AutoCAD SHX Text

AUDIO CABLE

AutoCAD SHX Text THIS SYMBOL WITH A NUMBER INSIDE REFERS TO KEYNOTES. REFER TO NOTES ON THE SHEET OR WITHIN THE DETAIL FOR ADDITIONAL INFORMATION

AutoCAD SHX Text EQUIPMENT SCHEDULE. THIS SYMBOL WITH LETTERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.

AutoCAD SHX Text CABLE SCHEDULE. THIS SYMBOL WITH NUMBERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.

AutoCAD SHX Text AUDIO/VIDEO COMMUNICATIONS OUTLET. REFER TO THE ASSOCIATED AV SYSTEM DETAIL FOR REQUIREMENTS. ZZ REFERS TO HEIGHT OF OUTLET. 18" UNLESS OTHER WISE NOTED.

AutoCAD SHX Text SPEAKERS. SEE SPEAKER SCHEDULE ON TC301."X" REFERS TO SPEAKER TYPE. "ZZ" REFERS TO SPEAKER ZONE IF THIS IS A PAGING SPEAKER.

AutoCAD SHX Text AV SYSTEM DETAIL. REFER TO THIS SHEET AND DETAIL NUMBER FOR THE REQUIREMENTS OF THE…