This document set comprises audiovisual (AV) system construction drawings and specifications for a renovation project at Dexter High School in Dexter, Michigan, involving the installation of comprehensive audiovisual, sound reinforcement, and control systems for the auditorium and associated facilities. The project, designated as Drawing Number 25026D and issued for construction on March 9, 2026, includes detailed specifications for AV infrastructure, device placement, conduit routing, power requirements, and network connectivity. The scope encompasses installation of multiple loudspeaker systems (including column arrays, front-fill speakers, ceiling speakers, and subwoofers), flat-panel displays in various sizes (32 to 75 inches), wireless microphone systems with six quad wireless receivers, production intercom systems, video cameras, video projection equipment, assistive listening systems, and extensive data networking infrastructure. The project requires coordination between multiple trades, including electrical contractors for power and conduit installation, technology/data vendors for building LAN infrastructure, and AV system subcontractors for equipment installation and programming.

The audiovisual system design specifies 120VAC, 20-ampere dedicated circuits for power distribution, with current draw calculated at 43.2 amperes at typical maximum operation levels. Data cabling throughout the system utilizes CAT6A-rated copper cabling for both the dedicated AV-NET network (for audiovisual signal distribution) and connections to the building's standard Ethernet network. The installation includes detailed power sequencing requirements with DSP and network switches operating on non-switched, unswitched power, while amplifiers power on last and power off first to protect equipment. The project incorporates advanced networking with fiber optic links between main and stage equipment racks, Dante digital audio networking, NDI video over IP capability, and integration with existing fire alarm systems for audio muting functionality. All work is to be performed per applicable electrical codes, with acoustic caulking and fire-rated sealants required at all penetrations through acoustical partitions and fire-rated assemblies.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

20A

IG

20A

IG

20A

IG

20A

20A/208VAC 2P/3W

NEMA L6-20R

20A

IG

20A

IG

20A

IG

20A

IG

20A

IG

20A

IG

20A

IG

20A

IG

20A

IG

DEVICE /

LOCATION

DESCRIPTION

ADVISORY AUDIOVISUAL DATA DROP REQUIREMENTS

QTY

AV-NET

DATA

CIRCUITS

QTY

ETHERNET

DATA

CIRCUITS

DIV. 274115:

TECHNOLOGY:

2 0

PROVIDE AND TERMINATE 2EA. AV-NET DATA JACKS.

N/A.

DIV. 274115:

TECHNOLOGY:

2 0

PROVIDE AND TERMINATE 2EA. CONNECTORIZED AV-NET DATA CABLES.

N/A.

DIV. 274115:

TECHNOLOGY:

4 0

PROVIDE AND TERMINATE 2EA. AV-NET DATA JACKS. PROVIDE 2EA. LIGHTING DATA JACKS - COORDINATE WITH USERS FOR TERMINATION LOCATION.

N/A.

NOTES:

* : SEE AV ONELINE DIAGRAMS FOR QUANTITIES OF EACH CIRCUIT TYPE TERMINATING AT EACH EQUIPMENT LOCATION.

ETHERNET: COMMON BUILDING DATA NETWORK. PROVIDED AND INSTALLED BY TECHNOLOGY/DATA VENDOR.

AV-NET : DEDICATED DATA NETWORK FOR AV STREAMING DATA. PROVIDED AND INSTALLED BY DIV. 274115.

1. IN CONTEXT OF THE AUDIOVISUAL DOCUMENTS, THE BUILDING DATA "ETHERNET" NETWORK IS USED BY AV SYSTEMS FOR INTRANET AND INTERNET DATA ACCESS (WHERE REQUIRED, APPROPRIATE, AND/OR PERMITTED BY THE OWNER), AND IS SEPARATE AND DISTINCT FROM THE "AV-NET" DEDICATED AV NETWORK PROVIDED AND INSTALLED BY DIV. 274115 FOR USE IN DISTRIBUTION OF DIGITAL AUDIO, AUDIOVISUAL, AND CONTROL SIGNALS (AS DETAILED IN THE AUDIOVISUAL CONTRACT DOCUMENTS). THE INSTALLATION AND IMPLEMENTATION OF THE BUILDING DATA "ETHERNET" NETWORK IS BEYOND DIV. 274115 SCOPE AND IS PROVIDED BY THE PROJECT TECHNOLOGY/DATA VENDOR UNDER SEPARATE SPECIFICATION. DIV. 274115 SHALL COORDINATE

WITH FACILITY IT STAFF FOR CONFIGURATION AND ACCESS PARAMETERS.

2. ALL DATA CABLING SHOWN TO BE PROVIDED BY DIV. 274115 AUDIOVISUAL CONTRACTOR UNLESS EXPLICITLY NOTED OTHERWISE.

3. WHERE DATA CABLING IS NOTED TO BE PROVIDED BY DATACOMM/TECHNOLOGY VENDOR, COORDINATE AS REQUIRED.

4. ALL COPPER DATA CABLING AND CONNECTORS SHALL BE CAT6A RATED.

5. AV CONTRACTOR SHALL VERIFY ALL ETHERNET-BASED DEVICES ASSOCIATED WITH AUDIOVISUAL SYSTEMS ARE WITHIN ETHERNET DISTANCE LIMITATIONS FOR THE FULL LENGTH OF EACH CABLE RUN, TO INCLUDE PATCH CABLE LENGTHS. COORDINATE WITH ELECTRICAL INSTALLER REGARDING PATHWAY AND CABLE ROUTING FOR MOST DIRECT ROUTE FROM DEVICE TO TERMINATION POINT.

6. REFER TO AUDIOVISUAL INFRASTRUCTURE DRAWINGS IN THIS DRAWING SET FOR ALL DEVICE LOCATIONS.

7. REFER TO DATA ADVISORIES FOR TECHNOLOGY/DATA VENDOR-SUPPLIED BUILDING LAN OUTLETS ASSOCIATED WITH AUDIOVISUAL DEVICE PLATES / LOCATIONS.

AR

FB1

AL

AP

CA

CX

EX

CX

DIV. 274115:

TECHNOLOGY:

* 0

TERMINATE REMOTE AV-NET DATA CONNECTIONS AT AV RACK NETWORK SWITCH AND OTHER LOCAL EQUIPMENT AS SHOWN IN ONELINE DIAGRAM.

N/A.

S1

TV

A

TV

B

TV

C

TV

D

VP

WC

ER

SR

DIV. 274115:

TECHNOLOGY:

2 0

PROVIDE AND TERMINATE 2EA. AV-NET DATA JACKS.

N/A.

DIV. 274115:

TECHNOLOGY:

2 0

PROVIDE AND TERMINATE 2EA. AV-NET DATA JACKS.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. AV-NET DATA JACK.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

1 0

PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.

N/A.

DIV. 274115:

TECHNOLOGY:

* 0

TERMINATE REMOTE AV-NET DATA CONNECTIONS AT AV RACK NETWORK SWITCH AND OTHER LOCAL EQUIPMENT AS SHOWN IN ONELINE DIAGRAM.

N/A.

DIV. 274115:

TECHNOLOGY:

* 0 TERMINATE REMOTE AV-NET DATA CONNECTIONS AT AV RACK NETWORK SWITCH AND OTHER LOCAL EQUIPMENT AS SHOWN IN ONELINE DIAGRAM.

N/A.

ADVISORY AUDIOVISUAL POWER REQUIREMENTS

QTY: (120VAC 20-AMP SINGLE PHASE)

POWER CIRCUITS ASSOCIATED WITH SOUND/AV

SYSTEMS FROM DISTRIBUTION PANEL. CIRCUITS

SHALL NOT BE SERVED FROM PANEL

CONTAINING HARMONIC LOADS (MOTORS,

DIMMERS, BALLASTS, ETC.)

AVERAGE CURRENT DRAW AND HEAT LOADS

ASSOCIATED WITH SOUND/AV SYSTEMS IN

OPERATION WITH TYPICAL PROGRAM MATERIAL

WITH OCCASIONAL CLIPPING:

CURRENT DRAW:

HEAT LOAD(S):

43.2 AMPS @ 120VAC

N/A

NOTES:

1. POWER RACEWAY AND MODULAR

OUTLETS INSIDE RACKS FURNISHED BY

AUDIO/VISUAL SYSTEM

SUBCONTRACTOR AND TERMINATED BY

ELECTRICAL CONTRACTOR.

2. COORDINATE WITH ELECTRICAL

CONTRACTOR FOR EXACT

LOCATIONS AND TERMINATION OF AC

POWER.

3. REFER TO SOUND SYSTEM

SPECIFICATIONS UNDER "RELATED

WORK BY OTHERS" FOR ADDITIONAL

INFORMATION.

4. ALL CIRCUITS ARE 20 AMP ISOLATED

GROUND UNLESS OTHERWISE

NOTED.

5. CURRENT DRAW BASED ON 120VAC

CIRCUITS AT SECONDARY SIDE OF

ISOLATION TRANSFORMER.

TRANSFORMER TO BE SIZED BY

PROJECT ELECTRICAL ENGINEER.

6. CURRENT DRAW AND HEAT LOAD

FOR EACH SYSTEM SHOWN

REPRESENT AVERAGE LOADS FOR

SOUND SYSTEMS IN OPERATION

WITH PROGRAM MATERIAL AT

TYPICAL MAXIMUM LEVEL

OPERATION.

7. OUTBOARD PLUG-IN POWER

SEQUENCING SYSTEM CONTROLLER AND

ASSOCIATED REMOTED LOW-VOLTAGE

SWITCH SETS (WALL AND RACK

MOUNTED) FURNISHED AND INSTALLED

BY DIV. 274115 AV INSTALLER.

SCREEN

AR

FB1

EXISTING CIRCUIT AT ONSTAGE

MOTORIZED PROJECTION SCREEN.

EXISTING CIRCUIT AT HOUSE

CROSS-AISLE AV FLOOR BOX.

EXISTING CIRCUIT AT CONTROL

BOOTH DESKTOP RACK.

EXISTING CIRCUIT AT STAGE RACK.

EXISTING CIRCUIT(S) AT AMPLIFIER RACK.

FIELD-VERIFY EXISTING CIRCUIT QUANTITY.

EXISTING CIRCUIT AT HOUSE

REAR WALL VIDEO PROJECTOR.

SUPPLEMENTAL AUDIOVISUAL POWER CIRCUITS REQUIRED BEYOND EXISTING POWER CIRCUITING

TV

A

(01) DUPLEX RECEPTACLE TERMINATED AT

EACH LOCATION. THREE (3) LOCATIONS

MAY SHARE ONE (01) CIRCUIT.

S1

(01) DUPLEX RECEPTACLE TERMINATED AT

EACH LOCATION. MOUNT ADJACENT TO AV

PLATE. COORDINATE WITH AV INSTALLER.

TV

B

TV

C

TV

D

SR

DR

VP

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

NEW

NEW

NEW

NEW

(01) DUPLEX RECEPTACLE TERMINATED AT

EACH LOCATION. THREE (3) LOCATIONS

MAY SHARE ONE (01) CIRCUIT.

(01) DUPLEX RECEPTACLE TERMINATED AT

EACH LOCATION. THREE (3) LOCATIONS

MAY SHARE ONE (01) CIRCUIT.

(01) DUPLEX RECEPTACLE TERMINATED AT

EACH LOCATION. THREE (3) LOCATIONS

MAY SHARE ONE (01) CIRCUIT.

SINGLE PHASE DEDICATED CIRCUITS

(20-AMP CIRCUITS TERMINATED IN

DUPLEX RECEPTACLES UNLESS

OTHERWISE NOTED)(DIV. 26)

SOUND / AV SYSTEM POWER

DISTRIBUTION PANEL

EXISTING

ER

EXISTING CIRCUIT(S) AT MAIN EQUIPMENT

RACK. FIELD-VERIFY EXISTING CIRCUIT

QUANTITY.

EXISTING

EXISTING

NEW ADDITIONAL POWER CAPACITY REQUIRED

NEW

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

AV Coordination Advisories

25026D

AV0.01

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

AUDIOVISUAL SHEET LIST

NUMBER NAME

AV0.01 AV Coordination Advisories

AV0.02 Audiovisual Device Legend and Conduit Riser

AV0.03 Audiovisual Details

AV0.04 Audiovisual Details

AV1.0G Orchestra Pit Audiovisual Floor Plan - Zone 'G'

AV1.1G First Level Audiovisual Floor Plan - Zone 'G'

AV1.2G Second Level Audiovisual Floor Plan - Zone 'G'

AV2.1G First Level Audiovisual Reflected Ceiling Plan - Zone 'G'

AV2.2G Second Level Audiovisual Reflected Ceiling Plan - Zone 'G'

AV3.1 Audiovisual Building Sections

AV3.2 Audiovisual Building Sections

AV3.10 Enlarged Audiovisual Views

AV4.1 Audiovisual Connector Legend and System Notes

AV4.2 Audiovisual Plate Details

AV4.3 Audiovisual Plate Details

AV4.4 Audiovisual Plate Details

AV4.5 Audiovisual Plate Details

AV5.1 Audiovisual Rack Elevations

AV6.1 Audiovisual Oneline Diagram

AV6.2 Audiovisual Oneline Diagram

AV6.3 Audiovisual Oneline Diagram

AV6.4 Audiovisual Oneline Diagram

AV6.5 Audiovisual Oneline Diagram

AV6.6 Audiovisual Oneline Diagram

AV6.7 Audiovisual Oneline Diagram

AV6.8 Audiovisual Oneline Diagram

AV6.9 Audiovisual Oneline Diagram

1. ALL 120VAC POWER CONDUCTORS, POWER DISTRIBUTION PANELS, JUNCTION BOXES, TERMINAL PANELS, CONDUITS, WIREWAYS, POWER RECEPTACLES AND ALL OTHER DEVICES ASSOCIATED WITH 120VAC POWER CIRCUITS SHALL BE FURNISHED, INSTALLED AND TERMINATED UNDER DIVISION 26 UNLESS OTHERWISE NOTED.

2. ALL CONDUIT SHOWN IS FOR AUDIO/VISUAL AND SOUND REINFORCEMENT SYSTEMS AND IS NOT RELATED TO ANY CONDUIT FOR AC POWER.

3. ALL CONDUIT IS 3/4" EMT UNLESS OTHERWISE NOTED.

4. ALL CONDUIT CONNECTIONS SHALL BE FURNISHED WITH NYLON BUSHINGS TO PREVENT DAMAGE TO CABLES FROM BURRED OR UNEVENLY CUT CONDUIT.

5. USE INSULATED BUSHINGS TO CONNECT CONDUIT TO EQUIPMENT RACKS, TO INSULATE CONDUIT GROUND FROM EQUIPMENT RACK GROUND SYSTEM.

6. KEEP 90° BENDS TO A MINIMUM. THE CONDUIT SYSTEM SHALL NOT HAVE MORE THAN THREE 90° BENDS OR THEIR EQUIVALENT BETWEEN PULL BOXES.

7. ALL PULL BOXES AND OUTLET BOXES SHALL BE AT LEAST 3-1/2" DEEP.

8. ALL CONDUIT RUNS IN EXCESS OF 100 FEET SHALL HAVE INTERMEDIATE JUNCTION BOXES EVERY 100 FEET OR THREE BENDS, WHICHEVER COMES FIRST.

9. ALL AUDIO/VISUAL SYSTEM RELATED JUNCTION BOXES SHALL REMAIN ACCESSIBLE AT ALL TIMES.

10. INSTALL NYLON PULL STRINGS IN ALL EMPTY CONDUITS.

11. CAULK OR OTHERWISE SEAL ALL PENETRATIONS THROUGH ACOUSTICAL PARTITIONS AND BARRIERS.

12. ALL PENETRATIONS THROUGH FIRE-RATED WALLS AND ASSEMBLIES SHALL BE SEALED WITH FIRESTOP MATERIAL PER APPLICABLE CODE. REFER TO DIVISION 7.

13. ELECTRICAL CONTRACTOR SHALL REFER TO ELECTRICAL DRAWINGS FOR ALL 120VAC CONDUIT SIZING.

14. ELECTRICAL CONTRACTOR SHALL REFER TO OTHER DRAWINGS FOR NON-AUDIO/VISUAL SYSTEM RELATED ELECTRICAL INFORMATION FOR THESE AREAS.

AUDIO/VISUAL SYSTEM DRAWINGS DO NOT CONTAIN ALL ROOM ELECTRICAL REQUIREMENTS.

15. THE ELECTRICAL CONTRACTOR SHALL INSTALL AND WIRE ALL HIGH VOLTAGE DEVICES.

16. ALL POWER CIRCUITS SHALL BE 120VAC, 20 AMP DEDICATED CIRCUITS UNLESS OTHERWISE NOTED.

17. ELECTRICAL CONTRACTOR SHALL LABEL ALL CIRCUIT BREAKER POSITIONS IN ALL BREAKER PANELS.

18. INSTALL SEPARATE DEDICATED NEUTRAL CONDUCTOR FROM POWER DISTRIBUTION PANEL FOR EACH INDIVIDUAL CIRCUIT.

19. ALLOW MINIMUM 20% SPARE BREAKERS FOR EACH POWER DISTRIBUTION PANEL.

20. 120VAC POWER TO THE EQUIPMENT RACKS SHALL BE TERMINATED INSIDE THE RACKS BY DIV. 26 TO AUDIO/VISUAL SYSTEM SUBCONTRACTOR-SUPPLIED RACEWAY

OUTLETS.

21. CLEARLY LABEL BREAKER PANEL DOOR "AUDIO/VISUAL SYSTEM EQUIPMENT ONLY".

22. INTEGRATED RECESSED LOUDSPEAKER ASSEMBLIES SHALL BE FURNISHED AND INSTALLED BY THE AUDIO/VISUAL SYSTEMS CONTRACTOR. SHOULD SUBSTITUTE

EQUIPMENT BE PROVIDED BY THE AV CONTRACTOR THAT REQUIRE THE USE OF DEDICATED SEPARATE LOUDSPEAKER BACK-CANS, THE AV CONTRACTOR SHALL

SUPPLY SUCH DEVICES TO DIV. 26 FOR INSTALLATION.

23. ALL COMMON ENCLOSURES AND JUNCTION BOXES ASSOCIATED WITH AUDIOVISUAL SCOPES OF WORK, AS CALLED OUT IN THE AUDIOVISUAL DEVICE LEGEND, SHALL

BE PROVIDED AND INSTALLED BY DIV. 26, UNLESS EXPLICITLY NOTED OTHERWISE.

24. SPECIALTY ENCLOSURES AND INFRASTRUCTURE DEVICES ASSOCIATED WITH AUDIOVISUAL SCOPES OF WORK, AS CALLED OUT IN THE AUDIOVISUAL DEVICE LEGEND AND EXPLICITLY SPECIFIED IN SECTION 270534, SHALL BE PROVIDED BY DIV. 270534 TO DIV. 26 FOR INSTALLATION.

25. REFER TO "RELATED WORK IN OTHER SECTIONS" IN AUDIO/VISUAL SYSTEM SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION.

26. CONDUIT SHALL BE REQUIRED BETWEEN ANY AND ALL LOUDSPEAKERS. WHERE PLENUN-RATED LOUDSPEAKER CABLE IS ALLOWED BY CODE, THIS CONSULTANT WILL

CONSIDER SUBSTITUTION REQUESTS SUBMITTED FORMALLY BY THE CONSTRUCTION TEAM, APPROVAL OF WHICH IS SUBJECT TO THE BEST INTERESTS OF THE

PROJECT.

27. WIRE NOT INSTALLED IN EQUIPMENT RACKS, NOT PORTABLE, OR NOT INSTALLED IN CONDUIT SHALL BE FIRE-RATED AND MEET ALL APPLICABLE CODES.

ELECTRICAL & CONDUIT INSTALLATION NOTES

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

mfe Rectangle

TV

A

TV

B

TV

B

TV

A

WC

A

WL

B

WL

B

SR

AR

TV

C

TV

C

S6 S6

TV

C

ER

V

TV

D

CX

S1 S1

S6S6

TV

C

J J

SEE

ADVISORY

DATA

SCHEDULE

SEE

ADVISORY

POWER

RISER

DEVICE

TYPE

DESCRIPTION

AUDIOVISUAL DEVICE LEGEND

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING SURFACE-MOUNTED ENCLOSURE. FIELD-VERIFY ENCLOSURE DIMENSIONS. FIELD-VERIFY EXACT LOCATIONS.

EXISTING AT DOWNSTAGE WALLS.

REPLACE EXISTING WITH NEW. PLATE DIMENSIONS SHALL MATCH PERIMETER DIMENSIONS OF ENCLOSURE, WITH NO PROTRUDING EDGES. RE: DETAILS.

DOWNSTAGE INPUT / OUTPUT PLATES.

X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

N/A.

MOUNT TO WALL ABOVE CONTROL BOOTH WINDOWS. PROVIDE WALL PENETRATION FOR CABLING ABOVE CONTROL BOOTH CEILING.

MANUFACTURER'S MOUNTING ADAPTOR BRACKET.

ASSISTIVE LISTENING TRANSMITTING ANTENNA.

X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING ACE BACKSTAGE SUPER POCKET FLOOR BOX. FIELD-VERIFY EXACT LOCATION.

EXISTING AT AUDITORIUM CROSS-AISLE FLOOR.

REPLACE EXISTING WITH NEW ACE BACKSTAGE #PNL-120, CONFIGURED AS SHOWN. PROVIDE BLANK ACE BACKSTAGE PANEL AT UNOCCUPIED HALF OF FLOOR BOX. RE: DETAILS.

HOUSE CROSS-AISLE AV FLOOR BOX.

EXISTING X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING 1-GANG BOX. FIELD-VERIFY EXACT LOCATIONS.

EXISTING.

REPLACE EXISTING WITH NEW 1-GANG CUSTOM PLATE. RE: DETAILS.

2 X 6-PIN PRODUCTION INTERCOM JACKS.

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING 2-GANG BOX. FIELD-VERIFY EXACT LOCATIONS.

EXISTING.

2-GANG MANUFACTURER PLATE. REPLACE OLD WITH NEW VOLUME CONTROL.

VOLUME CONTROL (2-GANG).

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING FLOOR-MOUNTED EQUIPMENT RACK. FIELD-VERIFY EXACT LOCATIONS.

FLOOR - EXISTING.

STANDARD 19" RACK PANEL EQUIPMENT, BY DIV. 274115. PROVIDE BLANK PANELS FOR ALL UNPOPULATED RACK SPACES.

MAIN AUDIOVISUAL EQUIPMENT RACK.

EXISTING X

S2

S4

FB1

AR

SCREEN

ER

SR

DR

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING FLOOR-MOUNTED EQUIPMENT RACK. FIELD-VERIFY EXACT LOCATIONS.

FLOOR - EXISTING.

STANDARD 19" RACK PANEL EQUIPMENT, BY DIV. 274115. PROVIDE BLANK PANELS FOR ALL UNPOPULATED RACK SPACES.

AMPLIFIER RACK.

EXISTING X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING FLOOR-MOUNTED EQUIPMENT RACK. FIELD-VERIFY EXACT LOCATIONS.

FLOOR - EXISTING.

STANDARD 19" RACK PANEL EQUIPMENT, BY DIV. 274115. PROVIDE BLANK PANELS FOR ALL UNPOPULATED RACK SPACES.

STAGE EQUIPMENT RACK.

EXISTING X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

DESK-MOUNTED EQUIPMENT RACK.

DESKTOP.

STANDARD 19" RACK PANEL EQUIPMENT, BY DIV. 274115. PROVIDE BLANK PANELS FOR ALL UNPOPULATED RACK SPACES.

DESKTOP EQUIPMENT RACK. RE: SECTION 274115 FOR MODEL / SIZE AND CONFIGURATION OPTIONS REQUIRED.

EXISTING

FB2

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING ACE BACKSTAGE FULL POCKET FLOOR BOX. FIELD-VERIFY EXACT LOCATIONS.

EXISTING AT AUDITORIUM STAGE FLOOR.

REPLACE EXISTING WITH NEW ACE BACKSTAGE #PNL-120, CONFIGURED AS SHOWN. RE: DETAILS.

STAGE AV FLOOR BOX.

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING SURFACE-MOUNTED ENCLOSURE. FIELD-VERIFY ENCLOSURE DIMENSIONS. FIELD-VERIFY EXACT LOCATIONS.

EXISTING AT UPSTAGE WALLS.

REPLACE EXISTING WITH NEW. PLATE DIMENSIONS SHALL MATCH PERIMETER DIMENSIONS OF ENCLOSURE, WITH NO PROTRUDING EDGES. RE: DETAILS.

UPSTAGE INPUT / OUTPUT PLATES.

X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING SURFACE-MOUNTED ENCLOSURE. FIELD-VERIFY ENCLOSURE DIMENSIONS. FIELD-VERIFY EXACT LOCATIONS.

EXISTING AT ORCHESTRA PIT.

REPLACE EXISTING WITH NEW. PLATE DIMENSIONS SHALL MATCH PERIMETER DIMENSIONS OF ENCLOSURE, WITH NO PROTRUDING EDGES. RE: DETAILS.

ORCHESTRA PIT INPUT / OUTPUT PLATES.

X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING.

EXISTING.

N/A.

EXISTING ONSTAGE MOTORIZED PROJECTION SCREEN.

EXISTING

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

RACO 650 SHALLOW 1-GANG WALL BOX. MOUNT IN HORIZONTAL ORIENTATION.

SURFACE MOUNT AT 9'-4" A.F.F.

FSR, INC. SS-BRSH-BLK BRUSH PASS-THROUGH MODULE. PROVIDE MATCHING 1-GANG DECORA COVER PLATE.

55" FLAT PANEL DISPLAY WITH ARTICULATING WALL MOUNT AT STAGE. MOUNT WITH DISPLAY CENTERED AT 8'-0" A.F.F.

X X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

RACO 650 SHALLOW 1-GANG WALL BOX. MOUNT IN HORIZONTAL ORIENTATION.

SURFACE MOUNT AT 8'-0" A.F.F.

FSR, INC. SS-BRSH-BLK BRUSH PASS-THROUGH MODULE. PROVIDE MATCHING 1-GANG DECORA COVER PLATE.

43" FLAT PANEL DISPLAY WITH TILT WALL MOUNT AT DRESSING ROOMS. MOUNT WITH DISPLAY CENTERED AT 7'-0" A.F.F.

X X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

RACO 650 SHALLOW 1-GANG WALL BOX. MOUNT IN HORIZONTAL ORIENTATION.

SURFACE MOUNT AT 7'-6" A.F.F.

FSR, INC. SS-BRSH-BLK BRUSH PASS-THROUGH MODULE. PROVIDE MATCHING 1-GANG DECORA COVER PLATE.

75" FLAT PANEL DISPLAY WITH TILT WALL MOUNT AT LOBBIES. MOUNT WITH DISPLAY CENTERED AT 6'-0" A.F.F.

X X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

FSR, INC. SMWB-1G-BLK 1-GANG SURFACE MOUNT WALL BOX.

SURFACE MOUNT AT 4'-0" A.F.F.

FSR, INC. SS-BRSH-BLK BRUSH PASS-THROUGH MODULE. PROVIDE MATCHING 1-GANG DECORA COVER PLATE.

DESK-MOUNTED 32" FLAT PANEL DISPLAY AT LIGHT BOOTH.

X X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING SURFACE-MOUNTED ENCLOSURE. FIELD-VERIFY ENCLOSURE DIMENSIONS. FIELD-VERIFY EXACT LOCATIONS.

EXISTING AT CATWALK.

REPLACE EXISTING WITH NEW. PLATE DIMENSIONS SHALL MATCH PERIMETER DIMENSIONS OF ENCLOSURE, WITH NO PROTRUDING EDGES. RE: DETAILS.

CATWALK INPUT / OUTPUT PLATE.

IC

AL

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

N/A.

MOUNT TO WALL ABOVE CONTROL BOOTH WINDOWS. PROVIDE WALL PENETRATION FOR CABLING ABOVE CONTROL BOOTH CEILING.

MANUFACTURER'S MOUNTING ADAPTOR BRACKET.

DEDICATED AV SYSTEM WIRELESS ACCESS POINT.

X

AP

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

N/A.

SURFACE MOUNT AT 12'-6" A.F.F.

ATLAS SOUND AD-11BE MIC FLANGE (BLACK), AD-7B EXTENSION TUBE (FIELD-PAINT BLACK) AND AD14BE RIGHT-ANGLE EXTENSION TUBE (BLACK).

ACTIVE DIRECTIONAL WIRELESS MICROPHONE ANTENNA.

WL

A

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

N/A.

MOUNT TO WALL ABOVE CONTROL BOOTH WINDOWS. PROVIDE WALL PENETRATION FOR CABLING ABOVE CONTROL BOOTH CEILING.

MANUFACTURER'S MOUNTING ADAPTOR BRACKET.

PTZ VIDEO CAMERA.

X

CA

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

FSR, INC. SMWB-2G-BLK 2-GANG SURFACE MOUNT WALL BOX.

SURFACE MOUNT AT 10'-0" A.F.F.

2-GANG CUSTOM PLATE. RE: DETAILS. PROVIDE ATLAS SOUND AD-11BE MIC FLANGE (BLACK), AD-7B EXTENSION TUBE (FIELD-PAINT BLACK).

WIRELESS INTERCOM TRANSCEIVER ANTENNA.

X

WC

A

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING.

EXISTING.

EXISTING.

EXISTING WALL-MOUNTED VIDEO PROJECTOR.

EXISTING X

VP

V

EX

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

CONDUIT PASS-THROUGH.

PENETRATE WALL AT 12'-4" ABOVE STAGE LEVEL.

N/A. PROVIDE CONDUIT BUSHINGS AT ALL CONDUIT ENDS.

ACTIVE COLUMN ARRAY LOUDSPEAKERS. MOUNT WITH BOTTOM OF LOWER LOUDSPEAKER AT 12'-0" ABOVE STAGE FLOOR.

X X

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

ELECTROVOICE EVID-C6.2-G2 LOUDSPEAKER ASSEMBLY.

RECESS IN CEILING.

MANUFACTURER'S GRILLE.

ELECTROVOICE EVID-C6.2-G2 6.5" 70V CEILING LOUDSPEAKER ASSEMBLY.

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING. UTILIZE EXISTING PATHWAYS.

EXISTING.

N/A.

SUSPENDED DUAL 15" SUBWOOFER

TV

A

TV

B

TV

C

TV

D

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING. UTILIZE EXISTING PATHWAYS.

FIELD-VERIFY LOCATIONS OF EXISTING PATHWAYS.

N/A.

SUSPENDED 8" DOWNFILL LOUDSPEAKER.

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

N/A.

FLUSH MOUNT AT EXISTING WALL OPENINGS. MODIFY OPENING DIMENSIONS TO ACCOMMODATE NEW LOUDSPEAKER.

MANUFACTURER'S GRILLE. PAINT GRILLE AND FLANGE A COLOR SELECTED BY THE ARCHITECT. USE MANUFACTURER'S PAINT SHEILD AND PROTECT ALL LOUDSPEAKER COMPONENTS DURING PAINTING.

FRONT FILL LOUDSPEAKERS.

S1

S3

SB

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING. FIELD-VERIFY EXACT LOCATIONS.

EXISTING.

MANUFACTURER'S 2-GANG PLATE.

EXISTING VIDEO ENCODER WALL PLATE WITH HDMI INPUT.

X

CX

EX

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING 2-GANG BOX. FIELD-VERIFY EXACT LOCATIONS.

EXISTING.

REPLACE EXISTING WITH NEW 2-GANG CUSTOM PLATE. RE: DETAILS.

2 X 6-PIN PRODUCTION INTERCOM JACKS.

IC

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

FSR, INC. SMWB-2G-BLK 2-GANG SURFACE MOUNT WALL BOX.

SURFACE MOUNT AT 4'-0" A.F.F.

MANUFACTURER'S 2-GANG PLATE.

VIDEO ENCODER WALL PLATE WITH HDMI INPUT.

X

CX

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

FSR, INC. SMWB-1G-BLK 1-GANG SURFACE MOUNT WALL BOX.

SURFACE MOUNT AT 4'-0" A.F.F.

1-GANG MANUFACTURER PLATE.

VOLUME CONTROL (1-GANG).

V

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

EXISTING. FIELD-VERIFY EXACT LOCATIONS.

EXISTING.

PROVIDE COVER PLATE WITH GROMMET PASS-THROUGH. FIELD-VERIFY PLATE SIZE REQUIRED.

SURFACE MOUNTED 8" 70V LOUDSPEAKER WITH WALL MOUNT.

S5

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

FSR, INC. SMWB-2G-BLK 2-GANG SURFACE MOUNT WALL BOX.

SURFACE MOUNT AT 10'-0" A.F.F.

2-GANG CUSTOM PLATE.

PASSIVE 1/2-WAVE OMNI-DIRECTIONAL WIRELESS MICROPHONE ANTENNA.

WL

B

J

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

12"X12"X4" NEMA TYPE 1 JUNCTION BOX WITH SCREW COVER.

FIELD-COORDINATE MOUNTING LOCATION.

SCREW COVER.

CABLING JUNCTION BOX.

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

N/A.

SURFACE MOUNT AT 13'-10" ABOVE SECOND LEVEL.

ATLAS SOUND AD-11BE MIC FLANGE (BLACK), AD-7B EXTENSION TUBE (FIELD-PAINT BLACK).

WIRELESS INTERCOM TRANSCEIVER ANTENNA.

X

WC

B

ENCLOSURE:

MOUNTING:

PANEL:

DEVICE(S):

N/A. FREE-RUN CABLE AT ACCESSIBLE CEILING.

SURFACE MOUNT TIGHT TO CEILING.

N/A.

SURFACE MOUNTED 8" 70V LOUDSPEAKER WITH WALL MOUNT.

S6

CONDUIT STUBBED INTO ACCESSIBLE CEILING SPACE.

CONDUIT NOTES

1. RE-USE EXISTING CONDUITS AT EXISTING

DEVICE LOCATIONS.

2. INSTALLER SHALL FIELD-VERIFY EXISTING

CONDUIT PATHWAYS AND ADVISE ARCHITECT

AND CONSULTANT OF DISCREPANCIES WHICH

IMPACT SYSTEM CONNECTIVITY.

3. ALL NEW CONDUIT IS EMT UNLESS OTHERWISE

NOTED. ONLY NEW CONDUITS ARE SHOWN IN

THIS RISER DIAGRAM.

4. CONDUIT SIZE IS 3/4" UNLESS OTHERWISE

NOTED.

5. CONDUIT SHOWN IS ASSOCIATED WITH LOW-

VOLTAGE AUDIOVISUAL SYSTEM CABLING ONLY.

CONDUIT REQUIREMENTS FOR POWER

ASSOCIATED WITH AV DEVICE LOCATIONS SHALL

BE DETERMINED, SIZED, AND FURNISHED BY THE

ELECTRICAL CONTRACTOR.

6. CONDUIT STUBBED INTO ACCESSIBLE CEILING

SPACE, OPEN CEILING AT RACK ROOM OR

OTHER TECHNICAL SPACE (NON PUBLIC

CIRCULATION AREA), OR EXPOSED AS NOTED.

7. FIELD-COORDINATE ALL CONDUIT ROUTING.

MINIMIZE ANY EXPOSED CONDUIT; VERIFY

ROUTING OF ANY EXPOSED CONDUIT WITH

ARCH. PRIOR TO INSTALLATION.

8. COORDINATION REQUIRED BETWEEN

ELECTRICAL AND AUDIOVISUAL REGARDING

WALL/FLOOR PENETRATIONS OR CORES

ASSOCIATED WITH AUDIOVISUAL SYSTEM

DEVICES. ALL PENETRATIONS IN ACOUSTICALLY

SENSITIVE AREAS TO BE SEALED WITH

RESILIENT CAULK. PROVIDE FIRE-RATED

SEALANT AS/WHERE REQUIRED BY

SUPERSEDING CODE.

9. CONFORM TO ALL PROJECT REQUIREMENTS

AND ALL LOCAL, OR OTHERWISE SUPERSEDING,

CODES PERTAINING TO ACCEPTABLE AND/OR

APPROVED MATERIALS FOR CONDUITS AND

PATHWAYS INSTALLED BELOW GRADE, TO

INCLUDE ACCESSORIES REQUIRED FOR

MOUNTING, COUPLING, AND OTHERWISE

REQUIRED FOR A COMPLETE PATHWAY SYSTEM.

STAGE F120

AUDITORIUM

DRESSING F111 DRESSING F108

AMP

RACK

ROOM

CONDUIT PASS-THROUGH

AT PROSCENIUM WALL FOR

S1 LOUDSPEAKERS

CONDUIT PASS-THROUGH

AT PROSCENIUM WALL FOR

S1 LOUDSPEAKERS

MOUNT POWER AND AV

JUNCTION BOXES AT STAGE

SIDE OF PROSCENIUM WALL

LEVEL 1 LOBBY

LEVEL 2 LOBBY

SOUND BOOTH LIGHT BOOTH

AUDIOVISUAL CONDUIT RISER DIAGRAM

TERMINATE STUB OUTS AT

FRONT WALL AT NORTH END

OF CONTROL COUNTER.

ROUTE VIA CEILING BELOW.

TERMINATE ADJACENT TO

EXISTING JUNCTION BOX

BELOW CONTROL DESK.

STUB OUT

ABOVE CEILING

1"C.

1"C.

1"C.

1"C.

STUB OUT ABOVE CEILING

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Audiovisual Device Legend and Conduit Riser

25026D

AV0.02

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

HOUSE REAR WALL

CONTROL BOOTH WINDOW

AL ASSISTIVE LISTENING ANTENNA

(DIV. 274115)

EXISTING CONDUIT PASS-THROUGH. FIELD-

VERIFY SIZE.

AV DATA CABLE (DIV. 274115)

HOUSE REAR WALL

CONTROL BOOTH WINDOW

AP AV WIRELESS ACCESS POINT

(DIV. 274115)

EXISTING CONDUIT PASS-THROUGH. FIELD-

VERIFY SIZE.

AV DATA CABLE (DIV. 274115)

HOUSE REAR WALL

CONTROL BOOTH WINDOW

AL ASSISTIVE LISTENING ANTENNA (DIV.

274115)

EXISTING CONDUIT PASS-THROUGH. FIELD-

VERIFY SIZE.

AV DATA CABLE (DIV. 274115)

DOWNSTAGE WALL

FSR SMWB-2G-BLK SURFACE MOUNT WALL BOX

(PROVIDED BY DIV. 274115 TO ELECTRICAL

CONTRACTOR FOR INSTALLATION)

WIRELESS INTERCOM TRANSCEIVER. PROVIDE ATLAS

AD-7B EXTENSION TUBE (FIELD-PAINT BLACK)(DIV.

274115)

COVER PLATE AND AV DATA

CABLE (DIV. 274115)

CONDUIT (ELECTRICAL CONTRACTOR)

RE: ARCH FOR WALL TYPE AND CONDITIONS

RACO 650 JUNCTION BOX AND CONDUIT

(ELECTRICAL CONTRACTOR). PAINT

EXPOSED CONDUITS TO MATCH WALL.

55" FLAT PANEL DISPLAY WITH ARTICULATING

WALL MOUNT. ANCHOR TO WALL WITH

SUITABLE MASONRY ANCHORS. (DIV. 274115).

COVER PLATE AND AV DATA CABLE (DIV. 274115)

MEDIA DECODER BEHIND DISPLAY (DIV. 274115)

RE: ARCH FOR WALL TYPE AND CONDITIONS

RACO 650 JUNCTION BOX AND CONDUIT

(ELECTRICAL CONTRACTOR). PAINT

EXPOSED CONDUITS TO MATCH WALL.

43" FLAT PANEL DISPLAY WITH TILT WALL

MOUNT. ANCHOR TO WALL WITH SUITABLE

MASONRY ANCHORS. (DIV. 274115).

COVER PLATE AND AV DATA CABLE (DIV. 274115)

MEDIA DECOVER BEHIND DISPLAY (DIV. 274115)

HOUSE REAR WALL

CONTROL BOOTH WINDOW

EXISTING CONDUIT PASS-

THROUGH. FIELD-VERIFY SIZE.

ATLAS AD-11BE MIC FLANGE, AD-7B

EXTENSION TUBE (FIELD-PAINT BLACK),

AND AD14BE RIGH-ANGLE EXTENSION

TUBE (DIV. 274115)

ACTIVE DIRECTIONAL

WIRELESS MICROPHONE

ANTENNA (DIV. 274115)

50-OHM COAX CABLE WITH

RIGHT-ANGLE BNC

CONNECTOR (DIV. 274115)

DOWNSTAGE WALL

PASSIVE 1/2-WAVE OMNI-

DIRECTIONAL ANTENNA

(DIV. 274115)

COVER PLATE (DIV. 274115)

FSR SMWB-2G-BLK 2-GANG SURFACE

MOUNT WALL BOX (PROVIDED BY DIV.

274115 TO ELECTRICAL CONTRACTOR

FOR INSTALLATION)

CONDUIT (ELECTRICAL CONTRACTOR)

HOUSE REAR WALL

WIRELESS INTERCOM

TRANSCEIVER. PROVIDE ATLAS

AD-11BE MIC FLANGE (ANCHOR TO

WALL) AND AD-7B EXTENSION TUBE

(FIELD-PAINT BLACK)(DIV. 274115)

AV DATA CABLE (DIV. 274115)

EXISTING CONDUIT PASS-

THROUGH. FIELD-VERIFY SIZE.

CONTROL BOOTH WINDOW

75" FLAT PANEL DISPLAY WITH TILT

WALL MOUNT. PROVIDE SUITABLE

ANCHORS OR FASTENERS FOR WALL

TYPE AT EACH LOCATION. (DIV. 274115).

RACO 650 JUNCTION BOX AND CONDUIT

(ELECTRICAL CONTRACTOR). PAINT

EXPOSED CONDUITS TO MATCH WALL.

EXISTING CMU WALL. RE: ARCH. FOR WALL

TYPE AND CONDITIONS AT EACH LOCATION.

COVER PLATE AND AV DATA

CABLING (DIV. 274115)

MEDIA DECODER MOUNTED

BEHIND DISPLAY (DIV. 274115)

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Audiovisual Details

25026D

AV0.03

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

SCALE: 1 1/2" = 1'-0"

1 DETAIL - TYPE AL ASSISTIVE LISTENING ANTENNA

SCALE: 1 1/2" = 1'-0"

2 DETAIL - TYPE AP AV ACCESS POINT

SCALE: 1 1/2" = 1'-0"

3 DETAIL - TYPE CA VIDEO CAMERA

SCALE: 1 1/2" = 1'-0"

7 DETAIL - TYPE WC-A WIRELESS INTERCOM ANTENNA

SCALE: 1 1/2" = 1'-0"

4 DETAIL - TYPE TV-A DISPLAY

SCALE: 1 1/2" = 1'-0"

5 DETAIL - TYPE TV-B DISPLAY

SCALE: 1 1/2" = 1'-0"

9 DETAIL - TYPE WL-A WIRELESS MIC ANTENNA

SCALE: 1 1/2" = 1'-0"

10 DETAIL - TYPE WL-B WIRELESS MIC ANTENNA

SCALE: 1 1/2" = 1'-0"

8 DETAIL - TYPE WC-B WIRELESS INTERCOM ANTENNA

SCALE: 1 1/2" = 1'-0"

6 DETAIL - TYPE TV-C DISPLAY

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

EXITING WALL. FIELD-VERIFY CONDITIONS.

AV DATA CABLE TO SR STAGE RACK (DIV. 274115).

1.5" CONDUIT PASS-THROUGH (ELECTRICAL

CONTRACTOR). PROVIDE FIRE-RATED CAULKING

AFTER CABLING INSTALLATION.

ACTIVE COLUMN ARRAY ELEMENTS WITH

MOUNTING BRACKETS. ANCHOR TO STEEL PLATE

WITH SUITABLE FASTENERS. (DIV. 274115).

AV DATA AND POWER CABLES LINKING

ARRAY MODULES (DIV. 274115)

PORTABLE AV DATA AND POWER CABLES (DIV. 274115)

JUNCTION BOXES AND CONDUITS. DUPLEX

20A/120VAC RECEPTACLE ADJACENT TO AV

DATA PLATE (ELECTRICAL CONTRACTOR)

1/4" STEEL PLATE AT EACH SIDE OF WALL (60"H X

7"W X .25"D). DRILL AND TAP PLATE AT SPEAKER

SIDE OF WALL TO ACCEPT AC6 PIVOTING WALL

MOUNT FASTENERS FOR EACH LOUDSPEAKER

MODULE (MINIMUM OF 2 MOUNTING POINTS FOR

EACH SPEAKER MOUNT). PROVIDE THROUGH-

BOLTS AT 4 POINTS SANDWICHING PLATES TO

WALL. PAINT STEEL PLATE AT AUDIENCE SIDE OF

WALL A COLOR SELECTED BY THE ARCHITECT;

COORDINATE, AS REQUIRED. (DIV. 274115)

S T

E E

L P

L A

T E

H E

IG

H

T

'-0

WEIGHT OF LOUDSPEAKER ASSEMBLY WITH 2

LOUDSPEAKER MODULES, COUPLING BRACKET,

AND WALL MOUNTS IS APPROX. 150LBS.

SECTION

STAGE

REPLACE EXISTING FRONT-FILL

LOUDSPEAKERS WITH NEW SPECIFIED

DEVICES. MODIFY OPENING TO

ACCOMMODATE NEW

LOUDSPEAKERS. ROUTE NEW CABLE

VIA EXISTING PATHWAYS. (DIV. 274115)

FLOOR

SPEAKER GRILLE (DIV. 274115)

SCHEDULED CEILING. RE: ARCH.

CEILING SPEAKER ASSEMBLY

(DIV. 274115)

AT EXISTING LOCATIONS BEING

REPLACED, FIELD-VERIFY AND

UTILIZE EXISTING PATHWAY

INFRASTRUCTURE

CONDUIT STUB-UP FROM

VOLUME CONTROL

(ELECTRICAL CONTRACTOR)

SPEAKER CABLE. PROVIDE

PLENUM-RATED CABLE IF RETURN

AIR PLENUM. (DIV. 274115)

REPLACE EXISTING WALL-MOUNTED

LOUDSPEAKERS WITH NEW

SPECIFIED DEVICES. PROVIDE

SUITABLE FASTENERS FOR WALL

TYPE AT EACH LOCATION (DIV. 274115)

PROVIDE NEW SPEAKER CABLE AND

COVER PLATE. VERIFY EXISTING BOX

SIZE AND PROVIDE APPROPRIATE

SIZE COVER PLATE, TO INCLUDE

HOLE WITH GROMMET. (DIV. 274115)

EXISTING JUNCTION BOX AND

CONDUIT PATHWAYS - FIELD

VERIFY (DIV. 274115)

SUSPENSION CABLE AND

HARDWARE. SECURE TO EXISTING

UPPER STRUCTURE. PROVIDE

SUPPLEMENTAL STRUCTURE

(UNISTRUT), AS REQUIRED.

PROVIDE CEILING PENETRATIONS,

WHERE REQUIRED. (DIV. 274115)

EXISTING CEILING

SUSPENDED SUBWOOFER

(DIV. 274115)

8" LOUDSPEAKER WITH

MOUNTING YOKE. MOUNT

INVERTED SO HF HORN IS

AT BOTTOM. (DIV. 274115)

EXISTING CEILING

SPEAKER BRACKET (DIV. 274115)

SUSPENSION CABLE AND

HARDWARE. SECURE TO

EXISTING UPPER STRUCTURE.

PROVIDE SUPPLEMENTAL

STRUCTURE (UNISTRUT), AS

REQUIRED. (DIV. 274115)

SPEAKER CABLE. ROUTE TO TYPE AR

AMP RACK VIA EXISTING PATHWAYS.

FIELD-VERIFY (DIV. 274115)

S1 AV DATA PLATE

(DIV. 274115)

1.5" CONDUIT

PASS-THROUGH

(ELECTRICAL

CONTRACTOR)

20-AMP / 120VAC

DUPLEX RECEPTACLE

(ELECTRICAL

CONTRACTOR)

ELEVATION

NEW 8" 70V SURFACE MOUNTED

LOUDSPEAKER WITH MOUNTING

BRACKET. PROVIDE SUITABLE

FASTENERS FOR WALL TYPE AT

EACH LOCATION (DIV. 274115)

SPEAKER CABLE, FREE-RUN AT

ACCESSIBLE CEILING. PROVIDE

PLENUM-RATED CABLE IF

RETURN AIR PLENUM. (DIV.

274115)

EXISTING CEILING. FIELD-VERIFY

TYPE AND CONDITIONS.

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Audiovisual Details

25026D

AV0.04

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

SCALE: 1 1/2" = 1'-0"

1 DETAIL - TYPE S1 LOUDSPEAKER

SCALE: 1 1/2" = 1'-0"

3 DETAIL - TYPE S3 LOUDSPEAKER

SCALE: 1 1/2" = 1'-0"

4 DETAIL - TYPE S4 LOUDSPEAKER

SCALE: 1 1/2" = 1'-0"

5 DETAIL - TYPE S5 LOUDSPEAKER

SCALE: 1 1/2" = 1'-0"

7 DETAIL - TYPE SB SUBWOOFER

SCALE: 1 1/2" = 1'-0"

2 DETAIL - TYPE S2 LOUDSPEAKER

SCALE: 1 1/2" = 1'-0"

6 DETAIL - TYPE S6 LOUDSPEAKER

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

UP

J

J

H

H

G

G

F

F

E

E

6 6

5.6 5.6

5.3 5.3

4.6 4.6

4.2 4.2

3.8 3.8

3.2 3.2

3 3

5 5

4 4

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Orchestra Pit Audiovisual Floor Plan - Zone 'G'

25026D

AV1.0G

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

N

SCALE: 1/8" = 1'-0"

Orchestra Pit Audiovisual Floor Plan - Zone 'G'

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

SR

S3

S3

S3

S3

S3

S3

F B

FB2

FB2

CX EX

CX EX

WC

VEX

VEX

TVA

TVB

TVB

TVA

WLB

WLB

V

TV C

75"

TV C

75"

AV3.1

AV3.1

M

M

L.5

L.5

L

L

K

K

J

J

H

H

G

G

F

F

E

E

D

D

7.5 7.5

7 7

6 6

5.6 5.6

5.3 5.3

4.6 4.6

4.2 4.2

3.8 3.8

3.2 3.2

3 3

5 5

4 4

5.95.9

5.7 5.7

5.15.1

2.62.6

3.1 3.1

3.4 3.4

4.1 4.1

4.7 4.7 c.3 c.3

AV3.1

AV3.2

AV3.2

COORDINATE EXACT MOUNTING

LOCATION WITH OWNER AND

EXISTING FREE WALL SPACE

S5

S1

S1

HR# 1

30W

30W

15W

15W

30W

30W

HR# 3

30W EA.

S6

S6

P/O HR# 4

60W EA.

S6

S6

MOUNT CLEAR OF EXISTING

TRANSFORMER. FIELD-

COORDINATE AS REQUIRED.

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

First Level Audiovisual Floor Plan - Zone 'G'

25026D

AV1.1G

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

N

SCALE: 1/8" = 1'-0"

First Level Audiovisual Floor Plan - Zone 'G'

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

FE

C

FES

E R

D R

AR

IC

CX

VTV

D

IC

WL2WL1

TV C

75"

TV C

75"

M

M

L.5

L.5

L

L

K

K

J

J

H

H

G

G

F

F

E

E

D

D

C

C

6 6

5.6 5.6

5.3 5.3

4.6 4.6

4.2 4.2

3.8 3.8

3.2 3.2

3 3

5 5

4 4

5.95.9

B.1

B.1

5.7 5.7

5.15.1

2.62.6

C.1

C.1

3.1 3.1

3.4 3.4

4.1 4.1

4.7 4.7 c.3 c.3

VP - EXISTING

CA - NEW, AT 12'-6" ABOVE SECOND LEVEL

WC - NEW, AT 13'-10" ABOVE SECOND LEVEL

AP - NEW, AT 11'-6" ABOVE SECOND LEVEL

WL-A - NEW, AT 12'-6" ABOVE SECOND LEVEL

AL - NEW, AT 11'-6" ABOVE SECOND LEVEL

WL-A - NEW, AT 12'-6" ABOVE SECOND LEVEL

E X

IS

T

IN

G

P R

O J E

C T

IO

N

S C

R E

E N

S5

S5

S5

S5

S5

C Y

C L O

R A

M A

F

IE

L D

-V E

R

IF

Y L

IN

E

S E

T

S C

E N

IC

P

R O

JE

C

T

IO

N I M

A G

E W

ID

T

H

'-6

P/O HR# 4

60W EA.

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Second Level Audiovisual Floor Plan - Zone 'G'

25026D

AV1.2G

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

N

SCALE: 1/8" = 1'-0"

Second Level Audiovisual Floor Plan - Zone 'G'

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

S4 S4

S4 S4

PAINT EXPOSED STRUCTURE, TYP.

SHOP

EXP-P

F106

SCENE

SHOP

F112

DRESSING

F111

DRESSING

F108

INSTRUCTIONAL

ACT

F104

SHOP

EXP-P

F106

WORK

ROOM

EXP-P

F107

OFFICE

EX

F105

PROPS

F122

CORRIDOR

F121

STAGE

F120

CORRIDOR

F103

CORRIDOR

F103

EX

EX

EX

EX

EX

EX

EX

EX

TOILET

F109

TOILET

F110

EX

EX

EX

EX

EX

EX

EX

EX

EX

EX

EXEX

EX

EX

VARIES

10'-1"

EX

EX

A2.1F

A2.1D

ZONE 'D'

ZONE 'F'

CELLULOSIC FIBER

SPRAYED INSULATION TO

BE APPLIED AT F106 & F201.

12'-0"

'-6

3'

-3

M

M

L.5

L.5

L

L

K

K

J

J

H

H

G

G

F

F

E

E

D

D

C

C

7 7

6 6

5.6 5.6

5.3 5.3

4.6 4.6

4.2 4.2

3.8 3.8

3.2 3.2

3 3

5 5

4 4

5.95.9

B.1

B.1

5.7 5.7

5.15.1

2.62.6

C.1

C.1

3.1 3.1

3.4 3.4

4.1 4.1

4.7 4.7 c.3 c.3

HR# 2

15W EA.

REPLACE EXISTING SPEAKERS WITH

NEW AT LOCATIONS SHOWN.

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

First Level Audiovisual Reflected Ceiling Plan - Zone 'G'

25026D

AV2.1G

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

N

SCALE: 1/8" = 1'-0"

First Level Audiovisual Reflected Ceiling Plan - Zone 'G'

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

IC 2

IC 2

S4S4

M

M

L.5

L.5

L

L

K

K

J

J

H

H

G

G

F

F

E

E

D

D

C

C

7 7

6 6

5.6 5.6

5.3 5.3

4.6 4.6

4.2 4.2

3.8 3.8

3.2 3.2

3 3

5 5

4 4

5.95.9

B.1

B.1

5.7 5.7

5.15.1

2.62.6

C.1

C.1

3.1 3.1

3.4 3.4

4.1 4.1

4.7 4.7 c.3 c.3

S2

FIELD-COORDINATE EXACT

PLACEMENT WITH LINEAR

DIFFUSERS AT CEILING GAPS

SB

E X

IS

T

IN

G

P R

O J E

C T

IO

N

S C

R E

E N

S2

P/O HR# 2

15W EA.

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Second Level Audiovisual Reflected Ceiling Plan - Zone 'G'

25026D

AV2.2G

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

N

SCALE: 1/8" = 1'-0"

Second Level Audiovisual Reflected Ceiling Plan - Zone 'G'

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

M AX0

V O LU M E

FIRST LEVEL

100' - 0"

SECOND LEVEL

114' - 8"

THIRD LEVEL

129' - 4"

ORCHESTRA PIT

92' - 0"

ML.5LKJHGFEDc.3

CONTROL BOOTH

116' - 10 1/2"

S4 CEILING SPEAKER, TYP.

TV-B DISPLAY

EXISTING PROJECTION SCREEN

1 PLATE

TV-A DISPLAY

2 PLATE

3 PLATE

S1 COLUMN ARRAY SPEAKERS

S3 FRONT FILL SPEAKERS

TYPE 4 AND IC-2 BOXES AT CATWALK,

SUSPENDED MICROPHONES BELOW CATWALK

S2 DOWNFILL LOUDSPEAKERS

SB SUBWOOFER

S5 LOUDSPEAKERS

S4, V, IC-1, AND TV-D DEVICES

AT LIGHTING CONTROL BOOTH

REAR WALL DEVICES:

-AL ASSISTIVE LISTENING ANTENNA

-WL WIRELESS MIC ANTENNAS

-CA CAMERA

-AP ACCESS POINT

-WC-B WIRELESS INTERCOM ANTENNA

-EXISTING VIDEO PROJECTOR

EXISTING CYCLORAMA

SCENIC PROJECTION IMAGE AT CYC

S6 LOUDSPEAKERS

TV-C FLAT PANEL DISPLAYS (OBSCURED)

FIRST LEVEL

100' - 0"

SECOND LEVEL

114' - 8"

THIRD LEVEL

129' - 4"

ORCHESTRA PIT

92' - 0"

65.65.34.64.23.83.23 54

S1 COLUMN ARRAY LOUDSPEAKERS

UPSTAGE 2 PLATE

ORCHESTRA PIT 3 PLATE

EXISTING PROJECTION SCREEN

S2 DOWNFILL LOUDSPEAKER

S1 COLUMN ARRAY LOUDSPEAKERS

UPSTAGE 2 PLATE

ORCHESTRA PIT 3 PLATE

S2 DOWNFILL LOUDSPEAKER

SB SUBWOOFER

AR AMPLIFIER

EQUIPMENT RACK

FIRST LEVEL

100' - 0"

SECOND LEVEL

114' - 8"

THIRD LEVEL

129' - 4"

6 5.6 5.3 4.6 4.2 3.8 3.2 35 4

CONTROL BOOTH

116' - 10 1/2"

AV3.10

4COORDINATE MOUNTING FOR REAR WALL

DEVICES WITH EXISTING CURTAINS

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Audiovisual Building Sections

25026D

AV3.1

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

SCALE: 1/8" = 1'-0"

1 Audiovisual Section - Longitudinal

SCALE: 1/8" = 1'-0"

2 Audiovisual Section - Transverse

SCALE: 1/8" = 1'-0"

3 Audiovisual Section - House Rear

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

M AX0

V O LU M E

M AX0

V O LU M E

M AX0

V O LU M E

FIRST LEVEL

100' - 0"

SECOND LEVEL

114' - 8"

THIRD LEVEL

129' - 4"

6 5.6 5.3 4.6 4.2 3.8 3.2 35 4

TV-A DISPLAY

EXISTING STAGE RACK (SR),

NEW AV EQUIPMENT

1 PLATE

TV-A DISPLAY

1 PLATE

EXISTING PROJECTION SCREEN

PORTABLE STAGE I/O RACK

S1 POWER & DATA PLATES,

CONDUIT PASS-THROUGH

WL-B WIRELESS

MICROPHONE ANTENNA

WC WIRELESS INTERCOM

ANTENNA

S1 POWER & DATA PLATES,

CONDUIT PASS-THROUGH

FIRST LEVEL

100' - 0"

SECOND LEVEL

114' - 8"

THIRD LEVEL

129' - 4"

65.65.34.64.23.83.23 54

S5 LOUDSPEAKER, TYP.

TV-C FLAT PANEL DISPLAYTV-C FLAT PANEL DISPLAY S6 LOUDSPEAKER, TYP.

TV-C FLAT PANEL DISPLAY TV-C FLAT PANEL DISPLAY

FIRST LEVEL

100' - 0"

6 5.6 5.3 4.6 4.25 4

TV-B DISPLAY

V-EX VOLUME CONTROL

S4 CEILING SPEAKERS5 LOUDSPEAKER

V VOLUME CONTROL

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Audiovisual Building Sections

25026D

AV3.2

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

SCALE: 1/8" = 1'-0"

1 Audiovisual Section - Downstage Wall

SCALE: 1/8" = 1'-0"

2 Audiovisual Section - Lobby

SCALE: 1/8" = 1'-0"

3 Audiovisual Section - Dressing Rooms / Scene Shop

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

ER

DR

THIRD LEVEL

129' - 4"

CONTROL BOOTH

116' - 10 1/2"

ER EQUIPMENT RACK

DR DESKTOP RACK

MONITOR SPEAKERS

COMPUTER MONITOR, KEYBOARD, MOUSE

TOUCH CONTROL SCREEN

MONITOR CONTROLLER

DIGITAL MIXING CONSOLE

CX MEDIA ENCODER WALL PLATE

S4 CEILING SPEAKER

V VOLUME CONTROL

CAMERA CONTROLLER

EXISTING CONDUIT PASS-THROUGH

32" FLAT PANEL DISPLAY

PORTABLE WIRELESS

MICROPHONE RACKS

VIDEO PRODUCTION COMPUTER

ER EQUIPMENT RACK

DR DESKTOP RACK

PORTABLE WIRELESS

MICROPHONE RACKS

ER EQUIPMENT RACK

DR DESKTOP RACK

MONITOR SPEAKERS

TOUCH CONTROL SCREEN

MONITOR CONTROLLER

DIGITAL MIXING CONSOLE

VIDEO PRODUCTION COMPUTER MONITOR, KEYBOARD, MOUSE

TV-D OUTLET

V VOLUME CONTROL

IC-1 INTERCOM OUTLETS (EXISTING

LOCATIONS, REPLACE PLATES AND CABLING)

CX MEDIA ENCODER WALL PLATE

CAMERA CONTROLLER

SOUND BOOTHLIGHT BOOTH

TV-D 32" FLAT PANEL DISPLAY

PORTABLE WIRELESS MICROPHONE RACKS

WL-A WIRELESS MICROPHONE ANTENNA

AP AV WIRELESS ACCESS POINT

VP EXISTING VIDEO PROJECTOR

WL-A WIRELESS MICROPHONE ANTENNA

AL ASSISTIVE LISTENING ANTENNA

EXISTING CONDUIT PASS-THROUGH

CONTROL BOOTH WINDOWS BELOW

WC-B WIRELESS INTERCOM ANTENNACA VIDEO CAMERA

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Enlarged Audiovisual Views

25026D

AV3.10

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

SCALE: 1/2" = 1'-0"

1 Audiovisual Enlarged Elevation - Control Booths

SCALE: 1/2" = 1'-0"

2 Audiovisual Enlarged Section - Control Booths

SCALE: 1/2" = 1'-0"

3 Enlarged Audiovisual Control Booth Plan

SCALE: 1/2" = 1'-0"

4 Audiovisual Enlarged Elevation - House Rear Wall

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

AUDIOVISUAL CONNECTOR LEGEND

AUDIOVISUAL DEVICE PLATE NOTES

DSP AND CONTROL SCREEN PROGRAMMING NOTES

XLR MALE

XLR MALE

RIGHT ANGLE

XLR FEMALE

XLR MINI

FEMALE

1/4" TRS

1/4" TS

RCA MALE

TRS MINI MALE

SPEAKON

4-POLE

SPEAKON

8-POLE

CAT6A DATA

PLUG

DB9

HDMI

USB

BNC

PHOENIX

XLR FEMALE

3-PIN

XLR FEMALE

5-PIN

XLR MALE

3-PIN

XLR MALE

6-PIN

SWITCHCRAFT

6-PIN

CONFIGURATION

SPEAKON

4-POLE

SPEAKON

8-POLE

CABLE

PASS-THROUGH

GROMMET

75-OHM BNC

CAT6A

ETHERCON

DATA JACK

(AV-NET)

CAT6A DATA

JACK

(BUILDING

DATA)

OPTICAL-CON

DUA

HDMI

USB-3

POWERCON

20A INLET

POWERCON

20A OUTLET

POWERCON

TRUE1-TOP

16A INLET

50-OHM BNC

50-OHM TNC

POWERCON

TRUE1-TOP

16A OUTLET

POWERCON

TRUE1-TOP

16A COMBO

CAT6A

ETHERCON

DATA PLUG

FIBER OPTIC

DUPLEX LC

FIBER OPTIC

SIMPLEX SC

NEUTRIK "D"

SIZE BLANK

COVER

USB-C WITH 3'

REAR PIGTAIL

USB-C CABLE

1. AV CONTRACTOR SHALL FIELD-VERIFY AS-INSTALLED ENCLOSURE MODELS AND SIZES FOR ALL AUDIOVISUAL DEVICE LOCATIONS AND PROVIDE AV CONNECCTOR PLATES CORRESPONDING TO THOSE INSTALLED MODELS, SIZES, AND CONDITIONS.

2. AV CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND MAINTAIN FACTORY MOUNTING HOLE SPACING FOR ALL CUSTOM-MANUFACTURED INTERFACE PLATES.

3. AV CONTRACTOR SHALL COORDINATED WITH OTHER TRADES, AS REQUIRED, FOR DEVICE/SERVICE ALLOCATION AT LOCATIONS INDICATED.

4. REFER TO SPECIFICATION SECTION 274115 FOR SPECIFIC REQUIREMENTS.

A. THE SYSTEM SHALL BE PROGRAMMED SO THE

DEFAULT OPERATING CONDITION IS AUTO-POPULATED

UPON SYSTEM POWER-UP OR SYSTEM RE-BOOT.

B. INTERFACE WITH THE PRESENTATION AND CONTROL

SYSTEM AND PROGRAM ASSOCIATED TOUCH

CONTROL PANELS FOR USER CONTROL OF ALL

PARAMETERS NECESSARY FOR SUCCESSFUL

CONTROL AND OPERATION OF CONNECTED DEVICES

IN THE SYSTEM. COORDINATE WITH THE OWNER’S

REPRESENTATIVES AND THIS CONSULTANT ON

DESIRED CONTROL PANEL FUNCTIONALITY AND

GRAPHICAL USER INTERFACE AT EACH CONTROL

PANEL LOCATION. THE INSTALLER SHALL

ACCOMMODATE, AT NO ADDITIONAL COST, ONE (1)

TOUCH CONTROL SCREEN PROGRAMMING REVISION

POST-COMMISSIONING AND AFTER OWNER INITIAL USE

OF THE SYSTEM TO INCORPORATE COMMENTS

PERTAINING TO USER INTERFACE OPERATIONAL

ADJUSTMENTS AND USER PREFERENCES.

1. CONFIGURE FOR LEVELS, MUTES, AND ROUTING

OF EACH INDIVIDUAL ANALOG AND DIGITAL

SYSTEM INPUT ASSOCIATED WITH THE DEFAULT /

ASSEMBLY AUDIO AND VIDEO SOURCES, TO

INCLUDE THE FOLLOWING:

a. DEFAULT / ASSEMBLY WIRED MICROPHONE

INPUTS.

b. DEFAULT / ASSEMBLY WIRELESS

MICROPHONE INPUTS AT SR RACK.

c. DEFAULT / ASSEMBLY CD / BT / MEDIA

PLAYER AT SR RACK.

d. DIGITAL AUDIO STREAMS ASSOCIATED

WITH THE IP VIDEO DISTRIBUTION SYSTEM

ENCODER AND DECODER DEVICES. UTILIZE

SOFTWARE ROUTING VIA

DANTE/AES67/MEDIA STREAM RECEIVERS

AND TRANSMITTERS, WHERE REQUIRED.

2. CONFIGURE TOUCH CONTROL PANELS FOR

ASSIGNABLE ZONE AND GLOBAL ROUTING OF

PAGING MICROPHONES.

3. PROVIDE CAMERA PAN-TILT-ZOOM CONTROLS

FOR EACH CAMERA IN THE SYSTEM. FOR EACH

CAMERA, INCLUDE CONTROLS FOR RECALL OF 3

PRE-DEFINED PRESETS (COORDINATE WITH

OWNER’S REPRESENTATIVES), AS WELL AS

USER-CONFIGURABLE AND RECALLABLE

PRESETS.

4. PROVIDE INDEPENDENT ROUTING CONTROL

ASSOCIATED WITH EACH VIDEO SOURCE AND

RECEIVER IN THE SYSTEM, TO INCLUDE

CAMERAS, VIDEO INPUT AND OUTPUT INTERFACE

DEVICES, DIGITAL SIGNAGE PLAYERS, MEDIA

ENCODERS AND DECODERS, TELEVISION

DISPLAYS, VIDEO PROJECTORS, AND VIDEO

BOARDS.

5. PROVIDE SELECTIONS FOR VIDEO PROJECTOR

LENS PRESETS TO ACCOMMODATE THE

FOLLOWING:

a. VIDEO PRESENTATION AT ONSTAGE

MOTORIZED PRESENTATION PROJECTION

SCREEN.

b. SCENIC PROJECTION AT UPSTAGE

CYCLORAMA.

6. PROVIDE WIRELESS TABLET CONTROL OF THE

FOLLOWING:

a. DSP CONTROL VIA DSP MANUFACTURER’S

WIRELESS TABLET CONTROL APP OR WEB

SERVER, MIRRORING WIRED TOUCH

CONTROL SCREEN CONFIGURATION AND

FUNCTIONALITY.

b. DIGITAL MIXING CONSOLE CONTROL VIA

CONSOLE MANUFACTURER'S CONTROL

APP.

C. AT LOCATIONS WHERE TOUCH CONTROL SCREENS

ARE INTENDED TO BE THE MECHANISM BY WHICH

SYSTEM POWER IS CONTROLLED, PROGRAM TOUCH

CONTROL SCREENS FOR THIS FUNCTIONALITY,

ENSURING ASSOCIATED DSP / CONTROL PROCESSOR

AND NETWORK SWITCH DEVICES ARE POWERED FROM

NON-SEQUENCED, NON-SWITCHED POWER OUTLETS.

D. WHERE ACTIVE/SELF-POWERED LOUDSPEAKERS ARE

EMPLOYED, INCORPORATE IN POWER ON/OFF PRESET,

SYSTEM OUTPUT MUTES (BOTH ANALOG AND DIGITAL

OUTPUTS) AT POWER DOWN AND SYSTEM UN-MUTE AT

SYSTEM POWER-UP WITH CONTROL DELAY

PROGRAMMING SO ACTIVE LOUDSPEAKERS ARE UN-

MUTED AFTER ALL OTHER EQUIPMENT SEQUENCING IS

COMPLETE.

E. TERMINATE AND PROGRAM FIRE ALARM INTERFACE.

THE SYSTEM SHALL BE PROGRAMMED TO MUTE ALL

PROGRAM AUDIO UPON RECEIPT OF CONTROL SIGNAL

FROM THE FIRE ALARM SYSTEM. COORDINATE WITH

THE OWNER FOR LOCATION OF THIS FEED.

F. CONTRACTOR SHALL PROVIDE A REVIEW COPY OF THE

PROGRAMMING FILE TO THE CONSULTANT FOR

REVIEW AT THE LATEST FOUR (4) WEEKS PRIOR TO

SCHEDULED COMMISSIONING TRIP.

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Audiovisual Connector Legend and System Notes

25026D

AV4.1

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS

MIC (#) MIC (#) MIC (#) MIC (#) MIC (#) MIC (#)

MIC (#) MIC (#) MIC (#) MIC (#) MIC (#) MIC (#)

DEF. MIC (#) DEF. MON. (#) COM A/B COM A/B

MON. (#) MON. (#) TIE LINE (#) AV-NET (#) TIE LINE (#)TIE LINE (#)

MIC (#) MIC (#)

AV-NET (#) TIE LINE (#)

TIE LINE (#) TIE LINE (#) MON. (#) MON. (#)

MIC (#) MIC (#) MIC (#) MIC (#) MIC (#) MIC (#)

MON. (#) MON. (#) AV-NET (#)

TIE LINE (#) TIE LINE (#) LINE OUT (#) LINE OUT (#)

TIE LINE (#)

COM A/B COM A/B

MIC (#) MIC (#) MIC (#) MIC (#)

TIE LINE (#) TIE LINE (#)

COM A/B COM A/B

50-OHM BNC

ON PLATE

1/2-WAVE PASSIVE

OMNIDIRECTIONAL

ANTENNA

Consultants in Acoustics, 4006 Speedway

512.476.3464

Austin, TX 78751 www.baiaustin.com

Sound Reinforcement, and Audiovisual Technologies

Since 1935 LLC

N

T M P A R C H I T E C T U R E I N C

1191 WEST SQUARE LAKE ROAD

PH · 248.338.4561

BLOOMFIELD HILLS · MICHIGAN · 48302

EM · INFO@TMP-ARCHITECTURE.COM

REGISTRATION SEAL

CONSULTANT

ISSUE DATES

DRAWN

CHECKED

APPROVED

PROJECT NO.

DRAWING NO.

DATE: ISSUED FOR:

PROJECT TITLE

DRAWING TITLE

KEY PLAN

A

B

C

D

E

F

G

H

J

K

L

3/ 5/

:5

4:

A M

A u to d es k

D o cs

/2

_D

C S

_D ex te r

H S

R en o va ti o n s (A

,B ,D

,F ,G

,H ,J

D ex te r

H S

_A V

-R

.r vt

Dexter High School Fitness/Entry Addition

Audiovisual Plate Details

25026D

AV4.2

BIH

REB

Approver

Dexter, MI

Dexter Community Schools

SCALE: 12" = 1'-0"

1 PLATE DETAIL - TYPE 1 I/O PLATE

SCALE: 12" = 1'-0"

2 PLATE DETAIL - TYPE 2 I/O PLATE

SCALE: 12" = 1'-0"

3 PLATE DETAIL - TYPE 3 I/O PLATE

SCALE: 12" = 1'-0"

4 PLATE DETAIL - TYPE 4 I/O PLATE

SCA…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .