Appendix A - DHS Additions Drawings_Part1.pdf
PDF 29 MB Posted
- Solicitation number
- RFP DEXT 260000002142 1
- Issued by
- Washtenaw County, Detroit City, Michigan
About this file
This document set comprises audiovisual (AV) system construction drawings and specifications for a renovation project at Dexter High School in Dexter, Michigan, involving the installation of comprehensive audiovisual, sound reinforcement, and control systems for the auditorium and associated facilities. The project, designated as Drawing Number 25026D and issued for construction on March 9, 2026, includes detailed specifications for AV infrastructure, device placement, conduit routing, power requirements, and network connectivity. The scope encompasses installation of multiple loudspeaker systems (including column arrays, front-fill speakers, ceiling speakers, and subwoofers), flat-panel displays in various sizes (32 to 75 inches), wireless microphone systems with six quad wireless receivers, production intercom systems, video cameras, video projection equipment, assistive listening systems, and extensive data networking infrastructure. The project requires coordination between multiple trades, including electrical contractors for power and conduit installation, technology/data vendors for building LAN infrastructure, and AV system subcontractors for equipment installation and programming.
The audiovisual system design specifies 120VAC, 20-ampere dedicated circuits for power distribution, with current draw calculated at 43.2 amperes at typical maximum operation levels. Data cabling throughout the system utilizes CAT6A-rated copper cabling for both the dedicated AV-NET network (for audiovisual signal distribution) and connections to the building's standard Ethernet network. The installation includes detailed power sequencing requirements with DSP and network switches operating on non-switched, unswitched power, while amplifiers power on last and power off first to protect equipment. The project incorporates advanced networking with fiber optic links between main and stage equipment racks, Dante digital audio networking, NDI video over IP capability, and integration with existing fire alarm systems for audio muting functionality. All work is to be performed per applicable electrical codes, with acoustic caulking and fire-rated sealants required at all penetrations through acoustical partitions and fire-rated assemblies.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
20A
IG
20A
IG
20A
IG
20A
20A/208VAC 2P/3W
NEMA L6-20R
20A
IG
20A
IG
20A
IG
20A
IG
20A
IG
20A
IG
20A
IG
20A
IG
20A
IG
DEVICE /
LOCATION
DESCRIPTION
ADVISORY AUDIOVISUAL DATA DROP REQUIREMENTS
QTY
AV-NET
DATA
CIRCUITS
QTY
ETHERNET
DATA
CIRCUITS
DIV. 274115:
TECHNOLOGY:
2 0
PROVIDE AND TERMINATE 2EA. AV-NET DATA JACKS.
N/A.
DIV. 274115:
TECHNOLOGY:
2 0
PROVIDE AND TERMINATE 2EA. CONNECTORIZED AV-NET DATA CABLES.
N/A.
DIV. 274115:
TECHNOLOGY:
4 0
PROVIDE AND TERMINATE 2EA. AV-NET DATA JACKS. PROVIDE 2EA. LIGHTING DATA JACKS - COORDINATE WITH USERS FOR TERMINATION LOCATION.
N/A.
NOTES:
* : SEE AV ONELINE DIAGRAMS FOR QUANTITIES OF EACH CIRCUIT TYPE TERMINATING AT EACH EQUIPMENT LOCATION.
ETHERNET: COMMON BUILDING DATA NETWORK. PROVIDED AND INSTALLED BY TECHNOLOGY/DATA VENDOR.
AV-NET : DEDICATED DATA NETWORK FOR AV STREAMING DATA. PROVIDED AND INSTALLED BY DIV. 274115.
1. IN CONTEXT OF THE AUDIOVISUAL DOCUMENTS, THE BUILDING DATA "ETHERNET" NETWORK IS USED BY AV SYSTEMS FOR INTRANET AND INTERNET DATA ACCESS (WHERE REQUIRED, APPROPRIATE, AND/OR PERMITTED BY THE OWNER), AND IS SEPARATE AND DISTINCT FROM THE "AV-NET" DEDICATED AV NETWORK PROVIDED AND INSTALLED BY DIV. 274115 FOR USE IN DISTRIBUTION OF DIGITAL AUDIO, AUDIOVISUAL, AND CONTROL SIGNALS (AS DETAILED IN THE AUDIOVISUAL CONTRACT DOCUMENTS). THE INSTALLATION AND IMPLEMENTATION OF THE BUILDING DATA "ETHERNET" NETWORK IS BEYOND DIV. 274115 SCOPE AND IS PROVIDED BY THE PROJECT TECHNOLOGY/DATA VENDOR UNDER SEPARATE SPECIFICATION. DIV. 274115 SHALL COORDINATE
WITH FACILITY IT STAFF FOR CONFIGURATION AND ACCESS PARAMETERS.
2. ALL DATA CABLING SHOWN TO BE PROVIDED BY DIV. 274115 AUDIOVISUAL CONTRACTOR UNLESS EXPLICITLY NOTED OTHERWISE.
3. WHERE DATA CABLING IS NOTED TO BE PROVIDED BY DATACOMM/TECHNOLOGY VENDOR, COORDINATE AS REQUIRED.
4. ALL COPPER DATA CABLING AND CONNECTORS SHALL BE CAT6A RATED.
5. AV CONTRACTOR SHALL VERIFY ALL ETHERNET-BASED DEVICES ASSOCIATED WITH AUDIOVISUAL SYSTEMS ARE WITHIN ETHERNET DISTANCE LIMITATIONS FOR THE FULL LENGTH OF EACH CABLE RUN, TO INCLUDE PATCH CABLE LENGTHS. COORDINATE WITH ELECTRICAL INSTALLER REGARDING PATHWAY AND CABLE ROUTING FOR MOST DIRECT ROUTE FROM DEVICE TO TERMINATION POINT.
6. REFER TO AUDIOVISUAL INFRASTRUCTURE DRAWINGS IN THIS DRAWING SET FOR ALL DEVICE LOCATIONS.
7. REFER TO DATA ADVISORIES FOR TECHNOLOGY/DATA VENDOR-SUPPLIED BUILDING LAN OUTLETS ASSOCIATED WITH AUDIOVISUAL DEVICE PLATES / LOCATIONS.
AR
FB1
AL
AP
CA
CX
EX
CX
DIV. 274115:
TECHNOLOGY:
* 0
TERMINATE REMOTE AV-NET DATA CONNECTIONS AT AV RACK NETWORK SWITCH AND OTHER LOCAL EQUIPMENT AS SHOWN IN ONELINE DIAGRAM.
N/A.
S1
TV
A
TV
B
TV
C
TV
D
VP
WC
ER
SR
DIV. 274115:
TECHNOLOGY:
2 0
PROVIDE AND TERMINATE 2EA. AV-NET DATA JACKS.
N/A.
DIV. 274115:
TECHNOLOGY:
2 0
PROVIDE AND TERMINATE 2EA. AV-NET DATA JACKS.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. AV-NET DATA JACK.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
1 0
PROVIDE AND TERMINATE 1EA. CONNECTORIZED AV-NET DATA CABLE.
N/A.
DIV. 274115:
TECHNOLOGY:
* 0
TERMINATE REMOTE AV-NET DATA CONNECTIONS AT AV RACK NETWORK SWITCH AND OTHER LOCAL EQUIPMENT AS SHOWN IN ONELINE DIAGRAM.
N/A.
DIV. 274115:
TECHNOLOGY:
* 0 TERMINATE REMOTE AV-NET DATA CONNECTIONS AT AV RACK NETWORK SWITCH AND OTHER LOCAL EQUIPMENT AS SHOWN IN ONELINE DIAGRAM.
N/A.
ADVISORY AUDIOVISUAL POWER REQUIREMENTS
QTY: (120VAC 20-AMP SINGLE PHASE)
POWER CIRCUITS ASSOCIATED WITH SOUND/AV
SYSTEMS FROM DISTRIBUTION PANEL. CIRCUITS
SHALL NOT BE SERVED FROM PANEL
CONTAINING HARMONIC LOADS (MOTORS,
DIMMERS, BALLASTS, ETC.)
AVERAGE CURRENT DRAW AND HEAT LOADS
ASSOCIATED WITH SOUND/AV SYSTEMS IN
OPERATION WITH TYPICAL PROGRAM MATERIAL
WITH OCCASIONAL CLIPPING:
CURRENT DRAW:
HEAT LOAD(S):
43.2 AMPS @ 120VAC
N/A
NOTES:
1. POWER RACEWAY AND MODULAR
OUTLETS INSIDE RACKS FURNISHED BY
AUDIO/VISUAL SYSTEM
SUBCONTRACTOR AND TERMINATED BY
ELECTRICAL CONTRACTOR.
2. COORDINATE WITH ELECTRICAL
CONTRACTOR FOR EXACT
LOCATIONS AND TERMINATION OF AC
POWER.
3. REFER TO SOUND SYSTEM
SPECIFICATIONS UNDER "RELATED
WORK BY OTHERS" FOR ADDITIONAL
INFORMATION.
4. ALL CIRCUITS ARE 20 AMP ISOLATED
GROUND UNLESS OTHERWISE
NOTED.
5. CURRENT DRAW BASED ON 120VAC
CIRCUITS AT SECONDARY SIDE OF
ISOLATION TRANSFORMER.
TRANSFORMER TO BE SIZED BY
PROJECT ELECTRICAL ENGINEER.
6. CURRENT DRAW AND HEAT LOAD
FOR EACH SYSTEM SHOWN
REPRESENT AVERAGE LOADS FOR
SOUND SYSTEMS IN OPERATION
WITH PROGRAM MATERIAL AT
TYPICAL MAXIMUM LEVEL
OPERATION.
7. OUTBOARD PLUG-IN POWER
SEQUENCING SYSTEM CONTROLLER AND
ASSOCIATED REMOTED LOW-VOLTAGE
SWITCH SETS (WALL AND RACK
MOUNTED) FURNISHED AND INSTALLED
BY DIV. 274115 AV INSTALLER.
SCREEN
AR
FB1
EXISTING CIRCUIT AT ONSTAGE
MOTORIZED PROJECTION SCREEN.
EXISTING CIRCUIT AT HOUSE
CROSS-AISLE AV FLOOR BOX.
EXISTING CIRCUIT AT CONTROL
BOOTH DESKTOP RACK.
EXISTING CIRCUIT AT STAGE RACK.
EXISTING CIRCUIT(S) AT AMPLIFIER RACK.
FIELD-VERIFY EXISTING CIRCUIT QUANTITY.
EXISTING CIRCUIT AT HOUSE
REAR WALL VIDEO PROJECTOR.
SUPPLEMENTAL AUDIOVISUAL POWER CIRCUITS REQUIRED BEYOND EXISTING POWER CIRCUITING
TV
A
(01) DUPLEX RECEPTACLE TERMINATED AT
EACH LOCATION. THREE (3) LOCATIONS
MAY SHARE ONE (01) CIRCUIT.
S1
(01) DUPLEX RECEPTACLE TERMINATED AT
EACH LOCATION. MOUNT ADJACENT TO AV
PLATE. COORDINATE WITH AV INSTALLER.
TV
B
TV
C
TV
D
SR
DR
VP
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
NEW
NEW
NEW
NEW
(01) DUPLEX RECEPTACLE TERMINATED AT
EACH LOCATION. THREE (3) LOCATIONS
MAY SHARE ONE (01) CIRCUIT.
(01) DUPLEX RECEPTACLE TERMINATED AT
EACH LOCATION. THREE (3) LOCATIONS
MAY SHARE ONE (01) CIRCUIT.
(01) DUPLEX RECEPTACLE TERMINATED AT
EACH LOCATION. THREE (3) LOCATIONS
MAY SHARE ONE (01) CIRCUIT.
SINGLE PHASE DEDICATED CIRCUITS
(20-AMP CIRCUITS TERMINATED IN
DUPLEX RECEPTACLES UNLESS
OTHERWISE NOTED)(DIV. 26)
SOUND / AV SYSTEM POWER
DISTRIBUTION PANEL
EXISTING
ER
EXISTING CIRCUIT(S) AT MAIN EQUIPMENT
RACK. FIELD-VERIFY EXISTING CIRCUIT
QUANTITY.
EXISTING
EXISTING
NEW ADDITIONAL POWER CAPACITY REQUIRED
NEW
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
AV Coordination Advisories
25026D
AV0.01
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
AUDIOVISUAL SHEET LIST
NUMBER NAME
AV0.01 AV Coordination Advisories
AV0.02 Audiovisual Device Legend and Conduit Riser
AV0.03 Audiovisual Details
AV0.04 Audiovisual Details
AV1.0G Orchestra Pit Audiovisual Floor Plan - Zone 'G'
AV1.1G First Level Audiovisual Floor Plan - Zone 'G'
AV1.2G Second Level Audiovisual Floor Plan - Zone 'G'
AV2.1G First Level Audiovisual Reflected Ceiling Plan - Zone 'G'
AV2.2G Second Level Audiovisual Reflected Ceiling Plan - Zone 'G'
AV3.1 Audiovisual Building Sections
AV3.2 Audiovisual Building Sections
AV3.10 Enlarged Audiovisual Views
AV4.1 Audiovisual Connector Legend and System Notes
AV4.2 Audiovisual Plate Details
AV4.3 Audiovisual Plate Details
AV4.4 Audiovisual Plate Details
AV4.5 Audiovisual Plate Details
AV5.1 Audiovisual Rack Elevations
AV6.1 Audiovisual Oneline Diagram
AV6.2 Audiovisual Oneline Diagram
AV6.3 Audiovisual Oneline Diagram
AV6.4 Audiovisual Oneline Diagram
AV6.5 Audiovisual Oneline Diagram
AV6.6 Audiovisual Oneline Diagram
AV6.7 Audiovisual Oneline Diagram
AV6.8 Audiovisual Oneline Diagram
AV6.9 Audiovisual Oneline Diagram
1. ALL 120VAC POWER CONDUCTORS, POWER DISTRIBUTION PANELS, JUNCTION BOXES, TERMINAL PANELS, CONDUITS, WIREWAYS, POWER RECEPTACLES AND ALL OTHER DEVICES ASSOCIATED WITH 120VAC POWER CIRCUITS SHALL BE FURNISHED, INSTALLED AND TERMINATED UNDER DIVISION 26 UNLESS OTHERWISE NOTED.
2. ALL CONDUIT SHOWN IS FOR AUDIO/VISUAL AND SOUND REINFORCEMENT SYSTEMS AND IS NOT RELATED TO ANY CONDUIT FOR AC POWER.
3. ALL CONDUIT IS 3/4" EMT UNLESS OTHERWISE NOTED.
4. ALL CONDUIT CONNECTIONS SHALL BE FURNISHED WITH NYLON BUSHINGS TO PREVENT DAMAGE TO CABLES FROM BURRED OR UNEVENLY CUT CONDUIT.
5. USE INSULATED BUSHINGS TO CONNECT CONDUIT TO EQUIPMENT RACKS, TO INSULATE CONDUIT GROUND FROM EQUIPMENT RACK GROUND SYSTEM.
6. KEEP 90° BENDS TO A MINIMUM. THE CONDUIT SYSTEM SHALL NOT HAVE MORE THAN THREE 90° BENDS OR THEIR EQUIVALENT BETWEEN PULL BOXES.
7. ALL PULL BOXES AND OUTLET BOXES SHALL BE AT LEAST 3-1/2" DEEP.
8. ALL CONDUIT RUNS IN EXCESS OF 100 FEET SHALL HAVE INTERMEDIATE JUNCTION BOXES EVERY 100 FEET OR THREE BENDS, WHICHEVER COMES FIRST.
9. ALL AUDIO/VISUAL SYSTEM RELATED JUNCTION BOXES SHALL REMAIN ACCESSIBLE AT ALL TIMES.
10. INSTALL NYLON PULL STRINGS IN ALL EMPTY CONDUITS.
11. CAULK OR OTHERWISE SEAL ALL PENETRATIONS THROUGH ACOUSTICAL PARTITIONS AND BARRIERS.
12. ALL PENETRATIONS THROUGH FIRE-RATED WALLS AND ASSEMBLIES SHALL BE SEALED WITH FIRESTOP MATERIAL PER APPLICABLE CODE. REFER TO DIVISION 7.
13. ELECTRICAL CONTRACTOR SHALL REFER TO ELECTRICAL DRAWINGS FOR ALL 120VAC CONDUIT SIZING.
14. ELECTRICAL CONTRACTOR SHALL REFER TO OTHER DRAWINGS FOR NON-AUDIO/VISUAL SYSTEM RELATED ELECTRICAL INFORMATION FOR THESE AREAS.
AUDIO/VISUAL SYSTEM DRAWINGS DO NOT CONTAIN ALL ROOM ELECTRICAL REQUIREMENTS.
15. THE ELECTRICAL CONTRACTOR SHALL INSTALL AND WIRE ALL HIGH VOLTAGE DEVICES.
16. ALL POWER CIRCUITS SHALL BE 120VAC, 20 AMP DEDICATED CIRCUITS UNLESS OTHERWISE NOTED.
17. ELECTRICAL CONTRACTOR SHALL LABEL ALL CIRCUIT BREAKER POSITIONS IN ALL BREAKER PANELS.
18. INSTALL SEPARATE DEDICATED NEUTRAL CONDUCTOR FROM POWER DISTRIBUTION PANEL FOR EACH INDIVIDUAL CIRCUIT.
19. ALLOW MINIMUM 20% SPARE BREAKERS FOR EACH POWER DISTRIBUTION PANEL.
20. 120VAC POWER TO THE EQUIPMENT RACKS SHALL BE TERMINATED INSIDE THE RACKS BY DIV. 26 TO AUDIO/VISUAL SYSTEM SUBCONTRACTOR-SUPPLIED RACEWAY
OUTLETS.
21. CLEARLY LABEL BREAKER PANEL DOOR "AUDIO/VISUAL SYSTEM EQUIPMENT ONLY".
22. INTEGRATED RECESSED LOUDSPEAKER ASSEMBLIES SHALL BE FURNISHED AND INSTALLED BY THE AUDIO/VISUAL SYSTEMS CONTRACTOR. SHOULD SUBSTITUTE
EQUIPMENT BE PROVIDED BY THE AV CONTRACTOR THAT REQUIRE THE USE OF DEDICATED SEPARATE LOUDSPEAKER BACK-CANS, THE AV CONTRACTOR SHALL
SUPPLY SUCH DEVICES TO DIV. 26 FOR INSTALLATION.
23. ALL COMMON ENCLOSURES AND JUNCTION BOXES ASSOCIATED WITH AUDIOVISUAL SCOPES OF WORK, AS CALLED OUT IN THE AUDIOVISUAL DEVICE LEGEND, SHALL
BE PROVIDED AND INSTALLED BY DIV. 26, UNLESS EXPLICITLY NOTED OTHERWISE.
24. SPECIALTY ENCLOSURES AND INFRASTRUCTURE DEVICES ASSOCIATED WITH AUDIOVISUAL SCOPES OF WORK, AS CALLED OUT IN THE AUDIOVISUAL DEVICE LEGEND AND EXPLICITLY SPECIFIED IN SECTION 270534, SHALL BE PROVIDED BY DIV. 270534 TO DIV. 26 FOR INSTALLATION.
25. REFER TO "RELATED WORK IN OTHER SECTIONS" IN AUDIO/VISUAL SYSTEM SPECIFICATION SECTIONS FOR ADDITIONAL INFORMATION.
26. CONDUIT SHALL BE REQUIRED BETWEEN ANY AND ALL LOUDSPEAKERS. WHERE PLENUN-RATED LOUDSPEAKER CABLE IS ALLOWED BY CODE, THIS CONSULTANT WILL
CONSIDER SUBSTITUTION REQUESTS SUBMITTED FORMALLY BY THE CONSTRUCTION TEAM, APPROVAL OF WHICH IS SUBJECT TO THE BEST INTERESTS OF THE
PROJECT.
27. WIRE NOT INSTALLED IN EQUIPMENT RACKS, NOT PORTABLE, OR NOT INSTALLED IN CONDUIT SHALL BE FIRE-RATED AND MEET ALL APPLICABLE CODES.
ELECTRICAL & CONDUIT INSTALLATION NOTES
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
mfe Rectangle
TV
A
TV
B
TV
B
TV
A
WC
A
WL
B
WL
B
SR
AR
TV
C
TV
C
S6 S6
TV
C
ER
V
TV
D
CX
S1 S1
S6S6
TV
C
J J
SEE
ADVISORY
DATA
SCHEDULE
SEE
ADVISORY
POWER
RISER
DEVICE
TYPE
DESCRIPTION
AUDIOVISUAL DEVICE LEGEND
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING SURFACE-MOUNTED ENCLOSURE. FIELD-VERIFY ENCLOSURE DIMENSIONS. FIELD-VERIFY EXACT LOCATIONS.
EXISTING AT DOWNSTAGE WALLS.
REPLACE EXISTING WITH NEW. PLATE DIMENSIONS SHALL MATCH PERIMETER DIMENSIONS OF ENCLOSURE, WITH NO PROTRUDING EDGES. RE: DETAILS.
DOWNSTAGE INPUT / OUTPUT PLATES.
X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
N/A.
MOUNT TO WALL ABOVE CONTROL BOOTH WINDOWS. PROVIDE WALL PENETRATION FOR CABLING ABOVE CONTROL BOOTH CEILING.
MANUFACTURER'S MOUNTING ADAPTOR BRACKET.
ASSISTIVE LISTENING TRANSMITTING ANTENNA.
X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING ACE BACKSTAGE SUPER POCKET FLOOR BOX. FIELD-VERIFY EXACT LOCATION.
EXISTING AT AUDITORIUM CROSS-AISLE FLOOR.
REPLACE EXISTING WITH NEW ACE BACKSTAGE #PNL-120, CONFIGURED AS SHOWN. PROVIDE BLANK ACE BACKSTAGE PANEL AT UNOCCUPIED HALF OF FLOOR BOX. RE: DETAILS.
HOUSE CROSS-AISLE AV FLOOR BOX.
EXISTING X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING 1-GANG BOX. FIELD-VERIFY EXACT LOCATIONS.
EXISTING.
REPLACE EXISTING WITH NEW 1-GANG CUSTOM PLATE. RE: DETAILS.
2 X 6-PIN PRODUCTION INTERCOM JACKS.
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING 2-GANG BOX. FIELD-VERIFY EXACT LOCATIONS.
EXISTING.
2-GANG MANUFACTURER PLATE. REPLACE OLD WITH NEW VOLUME CONTROL.
VOLUME CONTROL (2-GANG).
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING FLOOR-MOUNTED EQUIPMENT RACK. FIELD-VERIFY EXACT LOCATIONS.
FLOOR - EXISTING.
STANDARD 19" RACK PANEL EQUIPMENT, BY DIV. 274115. PROVIDE BLANK PANELS FOR ALL UNPOPULATED RACK SPACES.
MAIN AUDIOVISUAL EQUIPMENT RACK.
EXISTING X
S2
S4
FB1
AR
SCREEN
ER
SR
DR
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING FLOOR-MOUNTED EQUIPMENT RACK. FIELD-VERIFY EXACT LOCATIONS.
FLOOR - EXISTING.
STANDARD 19" RACK PANEL EQUIPMENT, BY DIV. 274115. PROVIDE BLANK PANELS FOR ALL UNPOPULATED RACK SPACES.
AMPLIFIER RACK.
EXISTING X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING FLOOR-MOUNTED EQUIPMENT RACK. FIELD-VERIFY EXACT LOCATIONS.
FLOOR - EXISTING.
STANDARD 19" RACK PANEL EQUIPMENT, BY DIV. 274115. PROVIDE BLANK PANELS FOR ALL UNPOPULATED RACK SPACES.
STAGE EQUIPMENT RACK.
EXISTING X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
DESK-MOUNTED EQUIPMENT RACK.
DESKTOP.
STANDARD 19" RACK PANEL EQUIPMENT, BY DIV. 274115. PROVIDE BLANK PANELS FOR ALL UNPOPULATED RACK SPACES.
DESKTOP EQUIPMENT RACK. RE: SECTION 274115 FOR MODEL / SIZE AND CONFIGURATION OPTIONS REQUIRED.
EXISTING
FB2
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING ACE BACKSTAGE FULL POCKET FLOOR BOX. FIELD-VERIFY EXACT LOCATIONS.
EXISTING AT AUDITORIUM STAGE FLOOR.
REPLACE EXISTING WITH NEW ACE BACKSTAGE #PNL-120, CONFIGURED AS SHOWN. RE: DETAILS.
STAGE AV FLOOR BOX.
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING SURFACE-MOUNTED ENCLOSURE. FIELD-VERIFY ENCLOSURE DIMENSIONS. FIELD-VERIFY EXACT LOCATIONS.
EXISTING AT UPSTAGE WALLS.
REPLACE EXISTING WITH NEW. PLATE DIMENSIONS SHALL MATCH PERIMETER DIMENSIONS OF ENCLOSURE, WITH NO PROTRUDING EDGES. RE: DETAILS.
UPSTAGE INPUT / OUTPUT PLATES.
X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING SURFACE-MOUNTED ENCLOSURE. FIELD-VERIFY ENCLOSURE DIMENSIONS. FIELD-VERIFY EXACT LOCATIONS.
EXISTING AT ORCHESTRA PIT.
REPLACE EXISTING WITH NEW. PLATE DIMENSIONS SHALL MATCH PERIMETER DIMENSIONS OF ENCLOSURE, WITH NO PROTRUDING EDGES. RE: DETAILS.
ORCHESTRA PIT INPUT / OUTPUT PLATES.
X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING.
EXISTING.
N/A.
EXISTING ONSTAGE MOTORIZED PROJECTION SCREEN.
EXISTING
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
RACO 650 SHALLOW 1-GANG WALL BOX. MOUNT IN HORIZONTAL ORIENTATION.
SURFACE MOUNT AT 9'-4" A.F.F.
FSR, INC. SS-BRSH-BLK BRUSH PASS-THROUGH MODULE. PROVIDE MATCHING 1-GANG DECORA COVER PLATE.
55" FLAT PANEL DISPLAY WITH ARTICULATING WALL MOUNT AT STAGE. MOUNT WITH DISPLAY CENTERED AT 8'-0" A.F.F.
X X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
RACO 650 SHALLOW 1-GANG WALL BOX. MOUNT IN HORIZONTAL ORIENTATION.
SURFACE MOUNT AT 8'-0" A.F.F.
FSR, INC. SS-BRSH-BLK BRUSH PASS-THROUGH MODULE. PROVIDE MATCHING 1-GANG DECORA COVER PLATE.
43" FLAT PANEL DISPLAY WITH TILT WALL MOUNT AT DRESSING ROOMS. MOUNT WITH DISPLAY CENTERED AT 7'-0" A.F.F.
X X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
RACO 650 SHALLOW 1-GANG WALL BOX. MOUNT IN HORIZONTAL ORIENTATION.
SURFACE MOUNT AT 7'-6" A.F.F.
FSR, INC. SS-BRSH-BLK BRUSH PASS-THROUGH MODULE. PROVIDE MATCHING 1-GANG DECORA COVER PLATE.
75" FLAT PANEL DISPLAY WITH TILT WALL MOUNT AT LOBBIES. MOUNT WITH DISPLAY CENTERED AT 6'-0" A.F.F.
X X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
FSR, INC. SMWB-1G-BLK 1-GANG SURFACE MOUNT WALL BOX.
SURFACE MOUNT AT 4'-0" A.F.F.
FSR, INC. SS-BRSH-BLK BRUSH PASS-THROUGH MODULE. PROVIDE MATCHING 1-GANG DECORA COVER PLATE.
DESK-MOUNTED 32" FLAT PANEL DISPLAY AT LIGHT BOOTH.
X X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING SURFACE-MOUNTED ENCLOSURE. FIELD-VERIFY ENCLOSURE DIMENSIONS. FIELD-VERIFY EXACT LOCATIONS.
EXISTING AT CATWALK.
REPLACE EXISTING WITH NEW. PLATE DIMENSIONS SHALL MATCH PERIMETER DIMENSIONS OF ENCLOSURE, WITH NO PROTRUDING EDGES. RE: DETAILS.
CATWALK INPUT / OUTPUT PLATE.
IC
AL
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
N/A.
MOUNT TO WALL ABOVE CONTROL BOOTH WINDOWS. PROVIDE WALL PENETRATION FOR CABLING ABOVE CONTROL BOOTH CEILING.
MANUFACTURER'S MOUNTING ADAPTOR BRACKET.
DEDICATED AV SYSTEM WIRELESS ACCESS POINT.
X
AP
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
N/A.
SURFACE MOUNT AT 12'-6" A.F.F.
ATLAS SOUND AD-11BE MIC FLANGE (BLACK), AD-7B EXTENSION TUBE (FIELD-PAINT BLACK) AND AD14BE RIGHT-ANGLE EXTENSION TUBE (BLACK).
ACTIVE DIRECTIONAL WIRELESS MICROPHONE ANTENNA.
WL
A
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
N/A.
MOUNT TO WALL ABOVE CONTROL BOOTH WINDOWS. PROVIDE WALL PENETRATION FOR CABLING ABOVE CONTROL BOOTH CEILING.
MANUFACTURER'S MOUNTING ADAPTOR BRACKET.
PTZ VIDEO CAMERA.
X
CA
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
FSR, INC. SMWB-2G-BLK 2-GANG SURFACE MOUNT WALL BOX.
SURFACE MOUNT AT 10'-0" A.F.F.
2-GANG CUSTOM PLATE. RE: DETAILS. PROVIDE ATLAS SOUND AD-11BE MIC FLANGE (BLACK), AD-7B EXTENSION TUBE (FIELD-PAINT BLACK).
WIRELESS INTERCOM TRANSCEIVER ANTENNA.
X
WC
A
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING.
EXISTING.
EXISTING.
EXISTING WALL-MOUNTED VIDEO PROJECTOR.
EXISTING X
VP
V
EX
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
CONDUIT PASS-THROUGH.
PENETRATE WALL AT 12'-4" ABOVE STAGE LEVEL.
N/A. PROVIDE CONDUIT BUSHINGS AT ALL CONDUIT ENDS.
ACTIVE COLUMN ARRAY LOUDSPEAKERS. MOUNT WITH BOTTOM OF LOWER LOUDSPEAKER AT 12'-0" ABOVE STAGE FLOOR.
X X
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
ELECTROVOICE EVID-C6.2-G2 LOUDSPEAKER ASSEMBLY.
RECESS IN CEILING.
MANUFACTURER'S GRILLE.
ELECTROVOICE EVID-C6.2-G2 6.5" 70V CEILING LOUDSPEAKER ASSEMBLY.
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING. UTILIZE EXISTING PATHWAYS.
EXISTING.
N/A.
SUSPENDED DUAL 15" SUBWOOFER
TV
A
TV
B
TV
C
TV
D
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING. UTILIZE EXISTING PATHWAYS.
FIELD-VERIFY LOCATIONS OF EXISTING PATHWAYS.
N/A.
SUSPENDED 8" DOWNFILL LOUDSPEAKER.
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
N/A.
FLUSH MOUNT AT EXISTING WALL OPENINGS. MODIFY OPENING DIMENSIONS TO ACCOMMODATE NEW LOUDSPEAKER.
MANUFACTURER'S GRILLE. PAINT GRILLE AND FLANGE A COLOR SELECTED BY THE ARCHITECT. USE MANUFACTURER'S PAINT SHEILD AND PROTECT ALL LOUDSPEAKER COMPONENTS DURING PAINTING.
FRONT FILL LOUDSPEAKERS.
S1
S3
SB
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING. FIELD-VERIFY EXACT LOCATIONS.
EXISTING.
MANUFACTURER'S 2-GANG PLATE.
EXISTING VIDEO ENCODER WALL PLATE WITH HDMI INPUT.
X
CX
EX
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING 2-GANG BOX. FIELD-VERIFY EXACT LOCATIONS.
EXISTING.
REPLACE EXISTING WITH NEW 2-GANG CUSTOM PLATE. RE: DETAILS.
2 X 6-PIN PRODUCTION INTERCOM JACKS.
IC
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
FSR, INC. SMWB-2G-BLK 2-GANG SURFACE MOUNT WALL BOX.
SURFACE MOUNT AT 4'-0" A.F.F.
MANUFACTURER'S 2-GANG PLATE.
VIDEO ENCODER WALL PLATE WITH HDMI INPUT.
X
CX
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
FSR, INC. SMWB-1G-BLK 1-GANG SURFACE MOUNT WALL BOX.
SURFACE MOUNT AT 4'-0" A.F.F.
1-GANG MANUFACTURER PLATE.
VOLUME CONTROL (1-GANG).
V
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
EXISTING. FIELD-VERIFY EXACT LOCATIONS.
EXISTING.
PROVIDE COVER PLATE WITH GROMMET PASS-THROUGH. FIELD-VERIFY PLATE SIZE REQUIRED.
SURFACE MOUNTED 8" 70V LOUDSPEAKER WITH WALL MOUNT.
S5
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
FSR, INC. SMWB-2G-BLK 2-GANG SURFACE MOUNT WALL BOX.
SURFACE MOUNT AT 10'-0" A.F.F.
2-GANG CUSTOM PLATE.
PASSIVE 1/2-WAVE OMNI-DIRECTIONAL WIRELESS MICROPHONE ANTENNA.
WL
B
J
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
12"X12"X4" NEMA TYPE 1 JUNCTION BOX WITH SCREW COVER.
FIELD-COORDINATE MOUNTING LOCATION.
SCREW COVER.
CABLING JUNCTION BOX.
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
N/A.
SURFACE MOUNT AT 13'-10" ABOVE SECOND LEVEL.
ATLAS SOUND AD-11BE MIC FLANGE (BLACK), AD-7B EXTENSION TUBE (FIELD-PAINT BLACK).
WIRELESS INTERCOM TRANSCEIVER ANTENNA.
X
WC
B
ENCLOSURE:
MOUNTING:
PANEL:
DEVICE(S):
N/A. FREE-RUN CABLE AT ACCESSIBLE CEILING.
SURFACE MOUNT TIGHT TO CEILING.
N/A.
SURFACE MOUNTED 8" 70V LOUDSPEAKER WITH WALL MOUNT.
S6
CONDUIT STUBBED INTO ACCESSIBLE CEILING SPACE.
CONDUIT NOTES
1. RE-USE EXISTING CONDUITS AT EXISTING
DEVICE LOCATIONS.
2. INSTALLER SHALL FIELD-VERIFY EXISTING
CONDUIT PATHWAYS AND ADVISE ARCHITECT
AND CONSULTANT OF DISCREPANCIES WHICH
IMPACT SYSTEM CONNECTIVITY.
3. ALL NEW CONDUIT IS EMT UNLESS OTHERWISE
NOTED. ONLY NEW CONDUITS ARE SHOWN IN
THIS RISER DIAGRAM.
4. CONDUIT SIZE IS 3/4" UNLESS OTHERWISE
NOTED.
5. CONDUIT SHOWN IS ASSOCIATED WITH LOW-
VOLTAGE AUDIOVISUAL SYSTEM CABLING ONLY.
CONDUIT REQUIREMENTS FOR POWER
ASSOCIATED WITH AV DEVICE LOCATIONS SHALL
BE DETERMINED, SIZED, AND FURNISHED BY THE
ELECTRICAL CONTRACTOR.
6. CONDUIT STUBBED INTO ACCESSIBLE CEILING
SPACE, OPEN CEILING AT RACK ROOM OR
OTHER TECHNICAL SPACE (NON PUBLIC
CIRCULATION AREA), OR EXPOSED AS NOTED.
7. FIELD-COORDINATE ALL CONDUIT ROUTING.
MINIMIZE ANY EXPOSED CONDUIT; VERIFY
ROUTING OF ANY EXPOSED CONDUIT WITH
ARCH. PRIOR TO INSTALLATION.
8. COORDINATION REQUIRED BETWEEN
ELECTRICAL AND AUDIOVISUAL REGARDING
WALL/FLOOR PENETRATIONS OR CORES
ASSOCIATED WITH AUDIOVISUAL SYSTEM
DEVICES. ALL PENETRATIONS IN ACOUSTICALLY
SENSITIVE AREAS TO BE SEALED WITH
RESILIENT CAULK. PROVIDE FIRE-RATED
SEALANT AS/WHERE REQUIRED BY
SUPERSEDING CODE.
9. CONFORM TO ALL PROJECT REQUIREMENTS
AND ALL LOCAL, OR OTHERWISE SUPERSEDING,
CODES PERTAINING TO ACCEPTABLE AND/OR
APPROVED MATERIALS FOR CONDUITS AND
PATHWAYS INSTALLED BELOW GRADE, TO
INCLUDE ACCESSORIES REQUIRED FOR
MOUNTING, COUPLING, AND OTHERWISE
REQUIRED FOR A COMPLETE PATHWAY SYSTEM.
STAGE F120
AUDITORIUM
DRESSING F111 DRESSING F108
AMP
RACK
ROOM
CONDUIT PASS-THROUGH
AT PROSCENIUM WALL FOR
S1 LOUDSPEAKERS
CONDUIT PASS-THROUGH
AT PROSCENIUM WALL FOR
S1 LOUDSPEAKERS
MOUNT POWER AND AV
JUNCTION BOXES AT STAGE
SIDE OF PROSCENIUM WALL
LEVEL 1 LOBBY
LEVEL 2 LOBBY
SOUND BOOTH LIGHT BOOTH
AUDIOVISUAL CONDUIT RISER DIAGRAM
TERMINATE STUB OUTS AT
FRONT WALL AT NORTH END
OF CONTROL COUNTER.
ROUTE VIA CEILING BELOW.
TERMINATE ADJACENT TO
EXISTING JUNCTION BOX
BELOW CONTROL DESK.
STUB OUT
ABOVE CEILING
1"C.
1"C.
1"C.
1"C.
STUB OUT ABOVE CEILING
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Audiovisual Device Legend and Conduit Riser
25026D
AV0.02
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
HOUSE REAR WALL
CONTROL BOOTH WINDOW
AL ASSISTIVE LISTENING ANTENNA
(DIV. 274115)
EXISTING CONDUIT PASS-THROUGH. FIELD-
VERIFY SIZE.
AV DATA CABLE (DIV. 274115)
HOUSE REAR WALL
CONTROL BOOTH WINDOW
AP AV WIRELESS ACCESS POINT
(DIV. 274115)
EXISTING CONDUIT PASS-THROUGH. FIELD-
VERIFY SIZE.
AV DATA CABLE (DIV. 274115)
HOUSE REAR WALL
CONTROL BOOTH WINDOW
AL ASSISTIVE LISTENING ANTENNA (DIV.
274115)
EXISTING CONDUIT PASS-THROUGH. FIELD-
VERIFY SIZE.
AV DATA CABLE (DIV. 274115)
DOWNSTAGE WALL
FSR SMWB-2G-BLK SURFACE MOUNT WALL BOX
(PROVIDED BY DIV. 274115 TO ELECTRICAL
CONTRACTOR FOR INSTALLATION)
WIRELESS INTERCOM TRANSCEIVER. PROVIDE ATLAS
AD-7B EXTENSION TUBE (FIELD-PAINT BLACK)(DIV.
274115)
COVER PLATE AND AV DATA
CABLE (DIV. 274115)
CONDUIT (ELECTRICAL CONTRACTOR)
RE: ARCH FOR WALL TYPE AND CONDITIONS
RACO 650 JUNCTION BOX AND CONDUIT
(ELECTRICAL CONTRACTOR). PAINT
EXPOSED CONDUITS TO MATCH WALL.
55" FLAT PANEL DISPLAY WITH ARTICULATING
WALL MOUNT. ANCHOR TO WALL WITH
SUITABLE MASONRY ANCHORS. (DIV. 274115).
COVER PLATE AND AV DATA CABLE (DIV. 274115)
MEDIA DECODER BEHIND DISPLAY (DIV. 274115)
RE: ARCH FOR WALL TYPE AND CONDITIONS
RACO 650 JUNCTION BOX AND CONDUIT
(ELECTRICAL CONTRACTOR). PAINT
EXPOSED CONDUITS TO MATCH WALL.
43" FLAT PANEL DISPLAY WITH TILT WALL
MOUNT. ANCHOR TO WALL WITH SUITABLE
MASONRY ANCHORS. (DIV. 274115).
COVER PLATE AND AV DATA CABLE (DIV. 274115)
MEDIA DECOVER BEHIND DISPLAY (DIV. 274115)
HOUSE REAR WALL
CONTROL BOOTH WINDOW
EXISTING CONDUIT PASS-
THROUGH. FIELD-VERIFY SIZE.
ATLAS AD-11BE MIC FLANGE, AD-7B
EXTENSION TUBE (FIELD-PAINT BLACK),
AND AD14BE RIGH-ANGLE EXTENSION
TUBE (DIV. 274115)
ACTIVE DIRECTIONAL
WIRELESS MICROPHONE
ANTENNA (DIV. 274115)
50-OHM COAX CABLE WITH
RIGHT-ANGLE BNC
CONNECTOR (DIV. 274115)
DOWNSTAGE WALL
PASSIVE 1/2-WAVE OMNI-
DIRECTIONAL ANTENNA
(DIV. 274115)
COVER PLATE (DIV. 274115)
FSR SMWB-2G-BLK 2-GANG SURFACE
MOUNT WALL BOX (PROVIDED BY DIV.
274115 TO ELECTRICAL CONTRACTOR
FOR INSTALLATION)
CONDUIT (ELECTRICAL CONTRACTOR)
HOUSE REAR WALL
WIRELESS INTERCOM
TRANSCEIVER. PROVIDE ATLAS
AD-11BE MIC FLANGE (ANCHOR TO
WALL) AND AD-7B EXTENSION TUBE
(FIELD-PAINT BLACK)(DIV. 274115)
AV DATA CABLE (DIV. 274115)
EXISTING CONDUIT PASS-
THROUGH. FIELD-VERIFY SIZE.
CONTROL BOOTH WINDOW
75" FLAT PANEL DISPLAY WITH TILT
WALL MOUNT. PROVIDE SUITABLE
ANCHORS OR FASTENERS FOR WALL
TYPE AT EACH LOCATION. (DIV. 274115).
RACO 650 JUNCTION BOX AND CONDUIT
(ELECTRICAL CONTRACTOR). PAINT
EXPOSED CONDUITS TO MATCH WALL.
EXISTING CMU WALL. RE: ARCH. FOR WALL
TYPE AND CONDITIONS AT EACH LOCATION.
COVER PLATE AND AV DATA
CABLING (DIV. 274115)
MEDIA DECODER MOUNTED
BEHIND DISPLAY (DIV. 274115)
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Audiovisual Details
25026D
AV0.03
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
SCALE: 1 1/2" = 1'-0"
1 DETAIL - TYPE AL ASSISTIVE LISTENING ANTENNA
SCALE: 1 1/2" = 1'-0"
2 DETAIL - TYPE AP AV ACCESS POINT
SCALE: 1 1/2" = 1'-0"
3 DETAIL - TYPE CA VIDEO CAMERA
SCALE: 1 1/2" = 1'-0"
7 DETAIL - TYPE WC-A WIRELESS INTERCOM ANTENNA
SCALE: 1 1/2" = 1'-0"
4 DETAIL - TYPE TV-A DISPLAY
SCALE: 1 1/2" = 1'-0"
5 DETAIL - TYPE TV-B DISPLAY
SCALE: 1 1/2" = 1'-0"
9 DETAIL - TYPE WL-A WIRELESS MIC ANTENNA
SCALE: 1 1/2" = 1'-0"
10 DETAIL - TYPE WL-B WIRELESS MIC ANTENNA
SCALE: 1 1/2" = 1'-0"
8 DETAIL - TYPE WC-B WIRELESS INTERCOM ANTENNA
SCALE: 1 1/2" = 1'-0"
6 DETAIL - TYPE TV-C DISPLAY
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
EXITING WALL. FIELD-VERIFY CONDITIONS.
AV DATA CABLE TO SR STAGE RACK (DIV. 274115).
1.5" CONDUIT PASS-THROUGH (ELECTRICAL
CONTRACTOR). PROVIDE FIRE-RATED CAULKING
AFTER CABLING INSTALLATION.
ACTIVE COLUMN ARRAY ELEMENTS WITH
MOUNTING BRACKETS. ANCHOR TO STEEL PLATE
WITH SUITABLE FASTENERS. (DIV. 274115).
AV DATA AND POWER CABLES LINKING
ARRAY MODULES (DIV. 274115)
PORTABLE AV DATA AND POWER CABLES (DIV. 274115)
JUNCTION BOXES AND CONDUITS. DUPLEX
20A/120VAC RECEPTACLE ADJACENT TO AV
DATA PLATE (ELECTRICAL CONTRACTOR)
1/4" STEEL PLATE AT EACH SIDE OF WALL (60"H X
7"W X .25"D). DRILL AND TAP PLATE AT SPEAKER
SIDE OF WALL TO ACCEPT AC6 PIVOTING WALL
MOUNT FASTENERS FOR EACH LOUDSPEAKER
MODULE (MINIMUM OF 2 MOUNTING POINTS FOR
EACH SPEAKER MOUNT). PROVIDE THROUGH-
BOLTS AT 4 POINTS SANDWICHING PLATES TO
WALL. PAINT STEEL PLATE AT AUDIENCE SIDE OF
WALL A COLOR SELECTED BY THE ARCHITECT;
COORDINATE, AS REQUIRED. (DIV. 274115)
S T
E E
L P
L A
T E
H E
IG
H
T
'-0
WEIGHT OF LOUDSPEAKER ASSEMBLY WITH 2
LOUDSPEAKER MODULES, COUPLING BRACKET,
AND WALL MOUNTS IS APPROX. 150LBS.
SECTION
STAGE
REPLACE EXISTING FRONT-FILL
LOUDSPEAKERS WITH NEW SPECIFIED
DEVICES. MODIFY OPENING TO
ACCOMMODATE NEW
LOUDSPEAKERS. ROUTE NEW CABLE
VIA EXISTING PATHWAYS. (DIV. 274115)
FLOOR
SPEAKER GRILLE (DIV. 274115)
SCHEDULED CEILING. RE: ARCH.
CEILING SPEAKER ASSEMBLY
(DIV. 274115)
AT EXISTING LOCATIONS BEING
REPLACED, FIELD-VERIFY AND
UTILIZE EXISTING PATHWAY
INFRASTRUCTURE
CONDUIT STUB-UP FROM
VOLUME CONTROL
(ELECTRICAL CONTRACTOR)
SPEAKER CABLE. PROVIDE
PLENUM-RATED CABLE IF RETURN
AIR PLENUM. (DIV. 274115)
REPLACE EXISTING WALL-MOUNTED
LOUDSPEAKERS WITH NEW
SPECIFIED DEVICES. PROVIDE
SUITABLE FASTENERS FOR WALL
TYPE AT EACH LOCATION (DIV. 274115)
PROVIDE NEW SPEAKER CABLE AND
COVER PLATE. VERIFY EXISTING BOX
SIZE AND PROVIDE APPROPRIATE
SIZE COVER PLATE, TO INCLUDE
HOLE WITH GROMMET. (DIV. 274115)
EXISTING JUNCTION BOX AND
CONDUIT PATHWAYS - FIELD
VERIFY (DIV. 274115)
SUSPENSION CABLE AND
HARDWARE. SECURE TO EXISTING
UPPER STRUCTURE. PROVIDE
SUPPLEMENTAL STRUCTURE
(UNISTRUT), AS REQUIRED.
PROVIDE CEILING PENETRATIONS,
WHERE REQUIRED. (DIV. 274115)
EXISTING CEILING
SUSPENDED SUBWOOFER
(DIV. 274115)
8" LOUDSPEAKER WITH
MOUNTING YOKE. MOUNT
INVERTED SO HF HORN IS
AT BOTTOM. (DIV. 274115)
EXISTING CEILING
SPEAKER BRACKET (DIV. 274115)
SUSPENSION CABLE AND
HARDWARE. SECURE TO
EXISTING UPPER STRUCTURE.
PROVIDE SUPPLEMENTAL
STRUCTURE (UNISTRUT), AS
REQUIRED. (DIV. 274115)
SPEAKER CABLE. ROUTE TO TYPE AR
AMP RACK VIA EXISTING PATHWAYS.
FIELD-VERIFY (DIV. 274115)
S1 AV DATA PLATE
(DIV. 274115)
1.5" CONDUIT
PASS-THROUGH
(ELECTRICAL
CONTRACTOR)
20-AMP / 120VAC
DUPLEX RECEPTACLE
(ELECTRICAL
CONTRACTOR)
ELEVATION
NEW 8" 70V SURFACE MOUNTED
LOUDSPEAKER WITH MOUNTING
BRACKET. PROVIDE SUITABLE
FASTENERS FOR WALL TYPE AT
EACH LOCATION (DIV. 274115)
SPEAKER CABLE, FREE-RUN AT
ACCESSIBLE CEILING. PROVIDE
PLENUM-RATED CABLE IF
RETURN AIR PLENUM. (DIV.
274115)
EXISTING CEILING. FIELD-VERIFY
TYPE AND CONDITIONS.
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Audiovisual Details
25026D
AV0.04
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
SCALE: 1 1/2" = 1'-0"
1 DETAIL - TYPE S1 LOUDSPEAKER
SCALE: 1 1/2" = 1'-0"
3 DETAIL - TYPE S3 LOUDSPEAKER
SCALE: 1 1/2" = 1'-0"
4 DETAIL - TYPE S4 LOUDSPEAKER
SCALE: 1 1/2" = 1'-0"
5 DETAIL - TYPE S5 LOUDSPEAKER
SCALE: 1 1/2" = 1'-0"
7 DETAIL - TYPE SB SUBWOOFER
SCALE: 1 1/2" = 1'-0"
2 DETAIL - TYPE S2 LOUDSPEAKER
SCALE: 1 1/2" = 1'-0"
6 DETAIL - TYPE S6 LOUDSPEAKER
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
UP
J
J
H
H
G
G
F
F
E
E
6 6
5.6 5.6
5.3 5.3
4.6 4.6
4.2 4.2
3.8 3.8
3.2 3.2
3 3
5 5
4 4
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Orchestra Pit Audiovisual Floor Plan - Zone 'G'
25026D
AV1.0G
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
N
SCALE: 1/8" = 1'-0"
Orchestra Pit Audiovisual Floor Plan - Zone 'G'
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
SR
S3
S3
S3
S3
S3
S3
F B
FB2
FB2
CX EX
CX EX
WC
VEX
VEX
TVA
TVB
TVB
TVA
WLB
WLB
V
TV C
75"
TV C
75"
AV3.1
AV3.1
M
M
L.5
L.5
L
L
K
K
J
J
H
H
G
G
F
F
E
E
D
D
7.5 7.5
7 7
6 6
5.6 5.6
5.3 5.3
4.6 4.6
4.2 4.2
3.8 3.8
3.2 3.2
3 3
5 5
4 4
5.95.9
5.7 5.7
5.15.1
2.62.6
3.1 3.1
3.4 3.4
4.1 4.1
4.7 4.7 c.3 c.3
AV3.1
AV3.2
AV3.2
COORDINATE EXACT MOUNTING
LOCATION WITH OWNER AND
EXISTING FREE WALL SPACE
S5
S1
S1
HR# 1
30W
30W
15W
15W
30W
30W
HR# 3
30W EA.
S6
S6
P/O HR# 4
60W EA.
S6
S6
MOUNT CLEAR OF EXISTING
TRANSFORMER. FIELD-
COORDINATE AS REQUIRED.
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
First Level Audiovisual Floor Plan - Zone 'G'
25026D
AV1.1G
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
N
SCALE: 1/8" = 1'-0"
First Level Audiovisual Floor Plan - Zone 'G'
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
FE
C
FES
E R
D R
AR
IC
CX
VTV
D
IC
WL2WL1
TV C
75"
TV C
75"
M
M
L.5
L.5
L
L
K
K
J
J
H
H
G
G
F
F
E
E
D
D
C
C
6 6
5.6 5.6
5.3 5.3
4.6 4.6
4.2 4.2
3.8 3.8
3.2 3.2
3 3
5 5
4 4
5.95.9
B.1
B.1
5.7 5.7
5.15.1
2.62.6
C.1
C.1
3.1 3.1
3.4 3.4
4.1 4.1
4.7 4.7 c.3 c.3
VP - EXISTING
CA - NEW, AT 12'-6" ABOVE SECOND LEVEL
WC - NEW, AT 13'-10" ABOVE SECOND LEVEL
AP - NEW, AT 11'-6" ABOVE SECOND LEVEL
WL-A - NEW, AT 12'-6" ABOVE SECOND LEVEL
AL - NEW, AT 11'-6" ABOVE SECOND LEVEL
WL-A - NEW, AT 12'-6" ABOVE SECOND LEVEL
E X
IS
T
IN
G
P R
O J E
C T
IO
N
S C
R E
E N
S5
S5
S5
S5
S5
C Y
C L O
R A
M A
F
IE
L D
-V E
R
IF
Y L
IN
E
S E
T
S C
E N
IC
P
R O
JE
C
T
IO
N I M
A G
E W
ID
T
H
'-6
P/O HR# 4
60W EA.
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Second Level Audiovisual Floor Plan - Zone 'G'
25026D
AV1.2G
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
N
SCALE: 1/8" = 1'-0"
Second Level Audiovisual Floor Plan - Zone 'G'
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
S4 S4
S4 S4
PAINT EXPOSED STRUCTURE, TYP.
SHOP
EXP-P
F106
SCENE
SHOP
F112
DRESSING
F111
DRESSING
F108
INSTRUCTIONAL
ACT
F104
SHOP
EXP-P
F106
WORK
ROOM
EXP-P
F107
OFFICE
EX
F105
PROPS
F122
CORRIDOR
F121
STAGE
F120
CORRIDOR
F103
CORRIDOR
F103
EX
EX
EX
EX
EX
EX
EX
EX
TOILET
F109
TOILET
F110
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EXEX
EX
EX
VARIES
10'-1"
EX
EX
A2.1F
A2.1D
ZONE 'D'
ZONE 'F'
CELLULOSIC FIBER
SPRAYED INSULATION TO
BE APPLIED AT F106 & F201.
12'-0"
'-6
3'
-3
M
M
L.5
L.5
L
L
K
K
J
J
H
H
G
G
F
F
E
E
D
D
C
C
7 7
6 6
5.6 5.6
5.3 5.3
4.6 4.6
4.2 4.2
3.8 3.8
3.2 3.2
3 3
5 5
4 4
5.95.9
B.1
B.1
5.7 5.7
5.15.1
2.62.6
C.1
C.1
3.1 3.1
3.4 3.4
4.1 4.1
4.7 4.7 c.3 c.3
HR# 2
15W EA.
REPLACE EXISTING SPEAKERS WITH
NEW AT LOCATIONS SHOWN.
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
First Level Audiovisual Reflected Ceiling Plan - Zone 'G'
25026D
AV2.1G
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
N
SCALE: 1/8" = 1'-0"
First Level Audiovisual Reflected Ceiling Plan - Zone 'G'
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
IC 2
IC 2
S4S4
M
M
L.5
L.5
L
L
K
K
J
J
H
H
G
G
F
F
E
E
D
D
C
C
7 7
6 6
5.6 5.6
5.3 5.3
4.6 4.6
4.2 4.2
3.8 3.8
3.2 3.2
3 3
5 5
4 4
5.95.9
B.1
B.1
5.7 5.7
5.15.1
2.62.6
C.1
C.1
3.1 3.1
3.4 3.4
4.1 4.1
4.7 4.7 c.3 c.3
S2
FIELD-COORDINATE EXACT
PLACEMENT WITH LINEAR
DIFFUSERS AT CEILING GAPS
SB
E X
IS
T
IN
G
P R
O J E
C T
IO
N
S C
R E
E N
S2
P/O HR# 2
15W EA.
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Second Level Audiovisual Reflected Ceiling Plan - Zone 'G'
25026D
AV2.2G
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
N
SCALE: 1/8" = 1'-0"
Second Level Audiovisual Reflected Ceiling Plan - Zone 'G'
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
M AX0
V O LU M E
FIRST LEVEL
100' - 0"
SECOND LEVEL
114' - 8"
THIRD LEVEL
129' - 4"
ORCHESTRA PIT
92' - 0"
ML.5LKJHGFEDc.3
CONTROL BOOTH
116' - 10 1/2"
S4 CEILING SPEAKER, TYP.
TV-B DISPLAY
EXISTING PROJECTION SCREEN
1 PLATE
TV-A DISPLAY
2 PLATE
3 PLATE
S1 COLUMN ARRAY SPEAKERS
S3 FRONT FILL SPEAKERS
TYPE 4 AND IC-2 BOXES AT CATWALK,
SUSPENDED MICROPHONES BELOW CATWALK
S2 DOWNFILL LOUDSPEAKERS
SB SUBWOOFER
S5 LOUDSPEAKERS
S4, V, IC-1, AND TV-D DEVICES
AT LIGHTING CONTROL BOOTH
REAR WALL DEVICES:
-AL ASSISTIVE LISTENING ANTENNA
-WL WIRELESS MIC ANTENNAS
-CA CAMERA
-AP ACCESS POINT
-WC-B WIRELESS INTERCOM ANTENNA
-EXISTING VIDEO PROJECTOR
EXISTING CYCLORAMA
SCENIC PROJECTION IMAGE AT CYC
S6 LOUDSPEAKERS
TV-C FLAT PANEL DISPLAYS (OBSCURED)
FIRST LEVEL
100' - 0"
SECOND LEVEL
114' - 8"
THIRD LEVEL
129' - 4"
ORCHESTRA PIT
92' - 0"
65.65.34.64.23.83.23 54
S1 COLUMN ARRAY LOUDSPEAKERS
UPSTAGE 2 PLATE
ORCHESTRA PIT 3 PLATE
EXISTING PROJECTION SCREEN
S2 DOWNFILL LOUDSPEAKER
S1 COLUMN ARRAY LOUDSPEAKERS
UPSTAGE 2 PLATE
ORCHESTRA PIT 3 PLATE
S2 DOWNFILL LOUDSPEAKER
SB SUBWOOFER
AR AMPLIFIER
EQUIPMENT RACK
FIRST LEVEL
100' - 0"
SECOND LEVEL
114' - 8"
THIRD LEVEL
129' - 4"
6 5.6 5.3 4.6 4.2 3.8 3.2 35 4
CONTROL BOOTH
116' - 10 1/2"
AV3.10
4COORDINATE MOUNTING FOR REAR WALL
DEVICES WITH EXISTING CURTAINS
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Audiovisual Building Sections
25026D
AV3.1
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
SCALE: 1/8" = 1'-0"
1 Audiovisual Section - Longitudinal
SCALE: 1/8" = 1'-0"
2 Audiovisual Section - Transverse
SCALE: 1/8" = 1'-0"
3 Audiovisual Section - House Rear
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
M AX0
V O LU M E
M AX0
V O LU M E
M AX0
V O LU M E
FIRST LEVEL
100' - 0"
SECOND LEVEL
114' - 8"
THIRD LEVEL
129' - 4"
6 5.6 5.3 4.6 4.2 3.8 3.2 35 4
TV-A DISPLAY
EXISTING STAGE RACK (SR),
NEW AV EQUIPMENT
1 PLATE
TV-A DISPLAY
1 PLATE
EXISTING PROJECTION SCREEN
PORTABLE STAGE I/O RACK
S1 POWER & DATA PLATES,
CONDUIT PASS-THROUGH
WL-B WIRELESS
MICROPHONE ANTENNA
WC WIRELESS INTERCOM
ANTENNA
S1 POWER & DATA PLATES,
CONDUIT PASS-THROUGH
FIRST LEVEL
100' - 0"
SECOND LEVEL
114' - 8"
THIRD LEVEL
129' - 4"
65.65.34.64.23.83.23 54
S5 LOUDSPEAKER, TYP.
TV-C FLAT PANEL DISPLAYTV-C FLAT PANEL DISPLAY S6 LOUDSPEAKER, TYP.
TV-C FLAT PANEL DISPLAY TV-C FLAT PANEL DISPLAY
FIRST LEVEL
100' - 0"
6 5.6 5.3 4.6 4.25 4
TV-B DISPLAY
V-EX VOLUME CONTROL
S4 CEILING SPEAKERS5 LOUDSPEAKER
V VOLUME CONTROL
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Audiovisual Building Sections
25026D
AV3.2
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
SCALE: 1/8" = 1'-0"
1 Audiovisual Section - Downstage Wall
SCALE: 1/8" = 1'-0"
2 Audiovisual Section - Lobby
SCALE: 1/8" = 1'-0"
3 Audiovisual Section - Dressing Rooms / Scene Shop
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
ER
DR
THIRD LEVEL
129' - 4"
CONTROL BOOTH
116' - 10 1/2"
ER EQUIPMENT RACK
DR DESKTOP RACK
MONITOR SPEAKERS
COMPUTER MONITOR, KEYBOARD, MOUSE
TOUCH CONTROL SCREEN
MONITOR CONTROLLER
DIGITAL MIXING CONSOLE
CX MEDIA ENCODER WALL PLATE
S4 CEILING SPEAKER
V VOLUME CONTROL
CAMERA CONTROLLER
EXISTING CONDUIT PASS-THROUGH
32" FLAT PANEL DISPLAY
PORTABLE WIRELESS
MICROPHONE RACKS
VIDEO PRODUCTION COMPUTER
ER EQUIPMENT RACK
DR DESKTOP RACK
PORTABLE WIRELESS
MICROPHONE RACKS
ER EQUIPMENT RACK
DR DESKTOP RACK
MONITOR SPEAKERS
TOUCH CONTROL SCREEN
MONITOR CONTROLLER
DIGITAL MIXING CONSOLE
VIDEO PRODUCTION COMPUTER MONITOR, KEYBOARD, MOUSE
TV-D OUTLET
V VOLUME CONTROL
IC-1 INTERCOM OUTLETS (EXISTING
LOCATIONS, REPLACE PLATES AND CABLING)
CX MEDIA ENCODER WALL PLATE
CAMERA CONTROLLER
SOUND BOOTHLIGHT BOOTH
TV-D 32" FLAT PANEL DISPLAY
PORTABLE WIRELESS MICROPHONE RACKS
WL-A WIRELESS MICROPHONE ANTENNA
AP AV WIRELESS ACCESS POINT
VP EXISTING VIDEO PROJECTOR
WL-A WIRELESS MICROPHONE ANTENNA
AL ASSISTIVE LISTENING ANTENNA
EXISTING CONDUIT PASS-THROUGH
CONTROL BOOTH WINDOWS BELOW
WC-B WIRELESS INTERCOM ANTENNACA VIDEO CAMERA
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Enlarged Audiovisual Views
25026D
AV3.10
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
SCALE: 1/2" = 1'-0"
1 Audiovisual Enlarged Elevation - Control Booths
SCALE: 1/2" = 1'-0"
2 Audiovisual Enlarged Section - Control Booths
SCALE: 1/2" = 1'-0"
3 Enlarged Audiovisual Control Booth Plan
SCALE: 1/2" = 1'-0"
4 Audiovisual Enlarged Elevation - House Rear Wall
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
AUDIOVISUAL CONNECTOR LEGEND
AUDIOVISUAL DEVICE PLATE NOTES
DSP AND CONTROL SCREEN PROGRAMMING NOTES
XLR MALE
XLR MALE
RIGHT ANGLE
XLR FEMALE
XLR MINI
FEMALE
1/4" TRS
1/4" TS
RCA MALE
TRS MINI MALE
SPEAKON
4-POLE
SPEAKON
8-POLE
CAT6A DATA
PLUG
DB9
HDMI
USB
BNC
PHOENIX
XLR FEMALE
3-PIN
XLR FEMALE
5-PIN
XLR MALE
3-PIN
XLR MALE
6-PIN
SWITCHCRAFT
6-PIN
CONFIGURATION
SPEAKON
4-POLE
SPEAKON
8-POLE
CABLE
PASS-THROUGH
GROMMET
75-OHM BNC
CAT6A
ETHERCON
DATA JACK
(AV-NET)
CAT6A DATA
JACK
(BUILDING
DATA)
OPTICAL-CON
DUA
HDMI
USB-3
POWERCON
20A INLET
POWERCON
20A OUTLET
POWERCON
TRUE1-TOP
16A INLET
50-OHM BNC
50-OHM TNC
POWERCON
TRUE1-TOP
16A OUTLET
POWERCON
TRUE1-TOP
16A COMBO
CAT6A
ETHERCON
DATA PLUG
FIBER OPTIC
DUPLEX LC
FIBER OPTIC
SIMPLEX SC
NEUTRIK "D"
SIZE BLANK
COVER
USB-C WITH 3'
REAR PIGTAIL
USB-C CABLE
1. AV CONTRACTOR SHALL FIELD-VERIFY AS-INSTALLED ENCLOSURE MODELS AND SIZES FOR ALL AUDIOVISUAL DEVICE LOCATIONS AND PROVIDE AV CONNECCTOR PLATES CORRESPONDING TO THOSE INSTALLED MODELS, SIZES, AND CONDITIONS.
2. AV CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND MAINTAIN FACTORY MOUNTING HOLE SPACING FOR ALL CUSTOM-MANUFACTURED INTERFACE PLATES.
3. AV CONTRACTOR SHALL COORDINATED WITH OTHER TRADES, AS REQUIRED, FOR DEVICE/SERVICE ALLOCATION AT LOCATIONS INDICATED.
4. REFER TO SPECIFICATION SECTION 274115 FOR SPECIFIC REQUIREMENTS.
A. THE SYSTEM SHALL BE PROGRAMMED SO THE
DEFAULT OPERATING CONDITION IS AUTO-POPULATED
UPON SYSTEM POWER-UP OR SYSTEM RE-BOOT.
B. INTERFACE WITH THE PRESENTATION AND CONTROL
SYSTEM AND PROGRAM ASSOCIATED TOUCH
CONTROL PANELS FOR USER CONTROL OF ALL
PARAMETERS NECESSARY FOR SUCCESSFUL
CONTROL AND OPERATION OF CONNECTED DEVICES
IN THE SYSTEM. COORDINATE WITH THE OWNER’S
REPRESENTATIVES AND THIS CONSULTANT ON
DESIRED CONTROL PANEL FUNCTIONALITY AND
GRAPHICAL USER INTERFACE AT EACH CONTROL
PANEL LOCATION. THE INSTALLER SHALL
ACCOMMODATE, AT NO ADDITIONAL COST, ONE (1)
TOUCH CONTROL SCREEN PROGRAMMING REVISION
POST-COMMISSIONING AND AFTER OWNER INITIAL USE
OF THE SYSTEM TO INCORPORATE COMMENTS
PERTAINING TO USER INTERFACE OPERATIONAL
ADJUSTMENTS AND USER PREFERENCES.
1. CONFIGURE FOR LEVELS, MUTES, AND ROUTING
OF EACH INDIVIDUAL ANALOG AND DIGITAL
SYSTEM INPUT ASSOCIATED WITH THE DEFAULT /
ASSEMBLY AUDIO AND VIDEO SOURCES, TO
INCLUDE THE FOLLOWING:
a. DEFAULT / ASSEMBLY WIRED MICROPHONE
INPUTS.
b. DEFAULT / ASSEMBLY WIRELESS
MICROPHONE INPUTS AT SR RACK.
c. DEFAULT / ASSEMBLY CD / BT / MEDIA
PLAYER AT SR RACK.
d. DIGITAL AUDIO STREAMS ASSOCIATED
WITH THE IP VIDEO DISTRIBUTION SYSTEM
ENCODER AND DECODER DEVICES. UTILIZE
SOFTWARE ROUTING VIA
DANTE/AES67/MEDIA STREAM RECEIVERS
AND TRANSMITTERS, WHERE REQUIRED.
2. CONFIGURE TOUCH CONTROL PANELS FOR
ASSIGNABLE ZONE AND GLOBAL ROUTING OF
PAGING MICROPHONES.
3. PROVIDE CAMERA PAN-TILT-ZOOM CONTROLS
FOR EACH CAMERA IN THE SYSTEM. FOR EACH
CAMERA, INCLUDE CONTROLS FOR RECALL OF 3
PRE-DEFINED PRESETS (COORDINATE WITH
OWNER’S REPRESENTATIVES), AS WELL AS
USER-CONFIGURABLE AND RECALLABLE
PRESETS.
4. PROVIDE INDEPENDENT ROUTING CONTROL
ASSOCIATED WITH EACH VIDEO SOURCE AND
RECEIVER IN THE SYSTEM, TO INCLUDE
CAMERAS, VIDEO INPUT AND OUTPUT INTERFACE
DEVICES, DIGITAL SIGNAGE PLAYERS, MEDIA
ENCODERS AND DECODERS, TELEVISION
DISPLAYS, VIDEO PROJECTORS, AND VIDEO
BOARDS.
5. PROVIDE SELECTIONS FOR VIDEO PROJECTOR
LENS PRESETS TO ACCOMMODATE THE
FOLLOWING:
a. VIDEO PRESENTATION AT ONSTAGE
MOTORIZED PRESENTATION PROJECTION
SCREEN.
b. SCENIC PROJECTION AT UPSTAGE
CYCLORAMA.
6. PROVIDE WIRELESS TABLET CONTROL OF THE
FOLLOWING:
a. DSP CONTROL VIA DSP MANUFACTURER’S
WIRELESS TABLET CONTROL APP OR WEB
SERVER, MIRRORING WIRED TOUCH
CONTROL SCREEN CONFIGURATION AND
FUNCTIONALITY.
b. DIGITAL MIXING CONSOLE CONTROL VIA
CONSOLE MANUFACTURER'S CONTROL
APP.
C. AT LOCATIONS WHERE TOUCH CONTROL SCREENS
ARE INTENDED TO BE THE MECHANISM BY WHICH
SYSTEM POWER IS CONTROLLED, PROGRAM TOUCH
CONTROL SCREENS FOR THIS FUNCTIONALITY,
ENSURING ASSOCIATED DSP / CONTROL PROCESSOR
AND NETWORK SWITCH DEVICES ARE POWERED FROM
NON-SEQUENCED, NON-SWITCHED POWER OUTLETS.
D. WHERE ACTIVE/SELF-POWERED LOUDSPEAKERS ARE
EMPLOYED, INCORPORATE IN POWER ON/OFF PRESET,
SYSTEM OUTPUT MUTES (BOTH ANALOG AND DIGITAL
OUTPUTS) AT POWER DOWN AND SYSTEM UN-MUTE AT
SYSTEM POWER-UP WITH CONTROL DELAY
PROGRAMMING SO ACTIVE LOUDSPEAKERS ARE UN-
MUTED AFTER ALL OTHER EQUIPMENT SEQUENCING IS
COMPLETE.
E. TERMINATE AND PROGRAM FIRE ALARM INTERFACE.
THE SYSTEM SHALL BE PROGRAMMED TO MUTE ALL
PROGRAM AUDIO UPON RECEIPT OF CONTROL SIGNAL
FROM THE FIRE ALARM SYSTEM. COORDINATE WITH
THE OWNER FOR LOCATION OF THIS FEED.
F. CONTRACTOR SHALL PROVIDE A REVIEW COPY OF THE
PROGRAMMING FILE TO THE CONSULTANT FOR
REVIEW AT THE LATEST FOUR (4) WEEKS PRIOR TO
SCHEDULED COMMISSIONING TRIP.
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Audiovisual Connector Legend and System Notes
25026D
AV4.1
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
03.09.2026 D.R. 1 - CONSTRUCTION DOCUMENTS
MIC (#) MIC (#) MIC (#) MIC (#) MIC (#) MIC (#)
MIC (#) MIC (#) MIC (#) MIC (#) MIC (#) MIC (#)
DEF. MIC (#) DEF. MON. (#) COM A/B COM A/B
MON. (#) MON. (#) TIE LINE (#) AV-NET (#) TIE LINE (#)TIE LINE (#)
MIC (#) MIC (#)
AV-NET (#) TIE LINE (#)
TIE LINE (#) TIE LINE (#) MON. (#) MON. (#)
MIC (#) MIC (#) MIC (#) MIC (#) MIC (#) MIC (#)
MON. (#) MON. (#) AV-NET (#)
TIE LINE (#) TIE LINE (#) LINE OUT (#) LINE OUT (#)
TIE LINE (#)
COM A/B COM A/B
MIC (#) MIC (#) MIC (#) MIC (#)
TIE LINE (#) TIE LINE (#)
COM A/B COM A/B
50-OHM BNC
ON PLATE
1/2-WAVE PASSIVE
OMNIDIRECTIONAL
ANTENNA
Consultants in Acoustics, 4006 Speedway
512.476.3464
Austin, TX 78751 www.baiaustin.com
Sound Reinforcement, and Audiovisual Technologies
Since 1935 LLC
N
T M P A R C H I T E C T U R E I N C
1191 WEST SQUARE LAKE ROAD
PH · 248.338.4561
BLOOMFIELD HILLS · MICHIGAN · 48302
EM · INFO@TMP-ARCHITECTURE.COM
REGISTRATION SEAL
CONSULTANT
ISSUE DATES
DRAWN
CHECKED
APPROVED
PROJECT NO.
DRAWING NO.
DATE: ISSUED FOR:
PROJECT TITLE
DRAWING TITLE
KEY PLAN
A
B
C
D
E
F
G
H
J
K
L
3/ 5/
:5
4:
A M
A u to d es k
D o cs
/2
_D
C S
_D ex te r
H S
R en o va ti o n s (A
,B ,D
,F ,G
,H ,J
D ex te r
H S
_A V
-R
.r vt
Dexter High School Fitness/Entry Addition
Audiovisual Plate Details
25026D
AV4.2
BIH
REB
Approver
Dexter, MI
Dexter Community Schools
SCALE: 12" = 1'-0"
1 PLATE DETAIL - TYPE 1 I/O PLATE
SCALE: 12" = 1'-0"
2 PLATE DETAIL - TYPE 2 I/O PLATE
SCALE: 12" = 1'-0"
3 PLATE DETAIL - TYPE 3 I/O PLATE
SCALE: 12" = 1'-0"
4 PLATE DETAIL - TYPE 4 I/O PLATE
SCA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .