AnimalShelter_DrawingsADD5_260623.pdf
PDF 7 MB Posted
- Attached to
- Animal Shelter Renovation and Addition
- Solicitation number
- 2026-ITB-359
- Issued by
- New Haven County, Connecticut
About this file
This document is Addendum #4 to the architectural and engineering drawings for the Animal Shelter Renovation and Addition project for the City of New Haven, Connecticut, dated June 23, 2026. The addendum modifies the contract documents for the renovation and approximately 700-square-foot addition to the existing animal shelter located at 81 Fournier Street, New Haven, Connecticut 06511. The project scope encompasses concrete trenching, patching, and masonry modifications; interior and exterior removals; plumbing, HVAC, and electrical modifications; and interior renovations including restrooms, break rooms, cat isolation rooms, laundry facilities, grooming rooms, and disinfection areas with new acoustical panel ceilings and LED lighting throughout. The addition consists of cast-in-place concrete walls and wood joist roof framing constructed into a rear slope and includes storage, dishwashing, and veterinary examination spaces. Exterior work includes concrete sidewalks and chain-link fencing. The addendum revises the drawing set originally issued April 10, 2026, incorporating updates to mechanical, electrical, plumbing, and structural support systems scheduled for release per the project timeline established in the contract documents.
The addendum includes comprehensive architectural specifications and details addressing partition types and lintels, door and frame schedules with hardware specifications, room finish schedules, casework and locker installations, toilet accessory mounting heights, interior elevations, exterior wall construction details, roof specifications with single-ply membrane requirements, and structural steel framing for HVAC unit support. Building code compliance is documented for Connecticut State Building Code and Fire Safety Code requirements, with construction type III-B designation, one-hour fire-rated corridors in the addition, and occupancy classifications for business use. The drawings establish specifications for materials including gypsum board, tile, epoxy flooring, paints and coatings, concrete reinforcement, masonry construction, roof insulation with R-30 minimum values, electrical systems with dedicated circuits and grounding requirements, and plumbing fixtures with ADA-compliant accessibility standards.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING SECTION
BUILDING ELEVATION
SHEET WHERE DETAIL APPEARS
DETAIL NUMBER
DOOR TAG
SPACE NUMBER / NAME
INTERIOR ELEVATION REFERENCE
DETAIL REFERENCE
WALL SECTION
AX.X
WINDOW TAG
VERTICAL DATUM POINT
X
1.01
REVISION CLOUD/ ADDENDUM
AX.X
X
AX.X
X
AX.X
X
ELEVATION
0' - 0"
SYMBOL DESCRIPTION REMARKS
ROOM NAME
W1 WALL TYPE TAG
SEE WINDOW SCHEDULE
SEE DOOR SCHEDULE
SEE FINISH SCHEDULE AND SPECIFICATIONS
SEE FLOOR PLAN LEGEND AND SPECIFICATIONS
SEE EXTERIOR ELEVATIONS
SEE BUILDING SECTIONS
SEE WALL SECTIONS
AX.X
X
SEE DETAILS
AX.X
X
SEE INTERIOR ELEVATIONS
WORK HAS BEEN MODIFIED SINCE PREVIOUS RELEASE
- REVIEW ALL DRAWING SHEETS IN SET -
AR.01 KEYNOTE TAG SEE KEYNOTE SCHEDULE
GYPSUM WALLBOARD
CONCRETE
GRAVEL
EARTH
STONE
STEEL OR OTHER MTLS
PLASTER FINISH
CONT ROUGH WOOD FRAMING
NOT CONT WOOD BLOCKING
PLYWOOD
FINISH WOOD
BATT INSULATION
RIGID INSULATION
CELLULOSE INSULATION
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
ABBREVIATIONS
MATERIAL SYMBOL LEGEND
DRAWING SYMBOL LEGEND
@ AT
A/C AIR CONDITIONING ACCESS
AB ANCHOR BOLT
ABV ABOVE
AC ACOUSTICAL
ACC ACCESS
ACFL ACCESS FLOOR
ACP ACOUSTICAL CEILING PANEL
ACR ACRYLIC PLASTER
ACT ACOUSTICAL TILE
AD AREA DRAIN
ADD ADDENDUM
ADH ADHESIVE
ADJ ADJUSTABLE
ADJT ADJACENT
AFF ABOVE FINISH FLOOR
AGG AGGREGATE
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANC ANCHORAGE
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE
APT APARTMENT
ARCH ARCHITECTURAL
ASB ASBESTOS
ASC ABOVE SUSPENDING CEILING
ASPH ASPHALT
AT ASPHALT TILE
AUTO AUTOMATIC
AV AUDIO VISUAL
AWP ACOUSTICAL WALL PANEL
BBD BULLETIN BOARD
BBR BASEBOARD RADIATION
BD BOARD
BEL BELOW
BIT BITUMINOUS
BJT BED JOINT
BLDG BUILDING
BLK(G) BLOCKING
BLST BLUESTONE
BM BEAM
BMK BENCH MARK
BO BY OWNER
BOT BOTTOM
BP BACK PLASTERED
BPL BEARING PLATE
BRK BRICK
BRZ BRONZE
BS BOTH SIDES
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT UP ROOF
BVL BEVELED
BW BOTH WAYS
CAB CABINET
CAD CADMIUM
CB CATCH BASIN
CEM CEMENT
CF CUBIC FOOT
CFL COUNTERFLASHING
CG CORNER GUARD
CHAM CHAMFER
CHBD CHALKBOARD
CHT CEILING HEIGHT
CI CAST IRON
CIPC CAST-IN-PLACE CONCRETE
CIR CIRCLE
CIRC CIRCUMFERENCE
CJT CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLK(G) CAULK(ING)
CLL CONTRACT LIMIT LINE
CLR CLEAR
CLS CLOSURE
CMT CERAMIC MOSAIC TILE
CMU CERAMIC MASONRY UNIT
COL COLUMN
COMB COMBINATION
COMP COMPRESS(ED)(ION)(IBLE)
COMPO COMPOSITE, COMPOSTION
COMPT COMPARTMENT
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COR CORRUGATED
CORR CORRIDOR
CPG COPING
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1/8" = 1'-0"
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK
COVER SHEET
CS
BID SET
General Information
CS COVER SHEET
Removals
R1.1 REMOVAL PLAN
Architectural
A0.1 CODE SHEET
A0.2 PARTITION TYPES AND LINTELS
A1.1 FLOOR PLAN
A1.2 ROOF PLAN AND SPECIFICATIONS
A2.1 REFLECTED CEILING PLAN
A3.0 EXTERIOR ELEVATIONS, BUILDING SECTION,
AND SPECIFICATIONS
A4.1 WALL SECTIONS
A4.2 WALL SECTIONS
A5.0 ROOF AND SIDEWALK DETAILS
DRAWING LIST
CPR COPPER
CPT CARPET
CR CHROMIUM PLATED
CRG CROSS GRAIN
CRS COURSE(S)
CS COUNTERSINK
CSMT CASEMENT
CST CAST STONE
CT CERAMIC TILE
CTHK COATHOOK
CTR COUNTER
CTSK COUNTERSUNK SCREW
CX CONNECTION
CY CUBIC YARD
D DRAIN
DA DOUBLEACTING
DEM DEMOLISH, DEMOLITION
DEP DEPRESSED
DET DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DIAG DIAGONAL
DIAM DIAMETER
DIM DIMENSION
DIV DIVISION
DL DEAD LOAD
DMPR DAMPER
DMT DEMOUNTABLE
DN DOWN
DP DAMPROOFING
DPL DISPOSAL
DPR DISPENSER
DR DOOR
DRB DRAINBOARD
DS DOWNSPOUT
DT DRAIN TILE
DTA DOVETAIL ANCHOR
DTS DOVETAIL ANCHOR SLOT
DW DISHWASHER
DWG DRAWING
DWR DRAWER
DWTR DUMBWAITER
(E) EXISTING
E EAST
EA EACH
EB EXPANSION BOLT
EF EXHAUST FAN
EJT EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC(AL)
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
EPBD ELECTRIC PANELBOARD
EPS EXTERIOR PAINT SYSTEM
EQ EQUAL
EQPT EQUIPMENT
ESCL ESCALATOR
ESTM ESTIMATE
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXCA EXCAVATE
EXG EXISTING
EXH EXHAUST
EXMP EXPANDED METAL PLATE
EXP EXPOSED
EXS EXTRA STRONG
EXT EXTERIOR
FA FIRE ALARM
FAI FRESH AIR INTAKE
FAS FASTENER
FB FACE BRICK
FBD FIBERBOARD
FBO FURNISHED BY OTHERS
FBRK FIRE BRICK
FD FLOOR DRAIN
FE-1 FIRE EXTINGUISHER - TYPE
FEC-1 FIRE EXTINGUISHER CABINET
FF FACTORY FINISH
FFE FINISHED FLOOR ELEVATION
FFL FINISHED FLOOR LINE
FG FIXED GLASS
FGL FIBERGLASS
FHMS FLATHEAD MACHINE SCREW
FHS FIRE HOSE STATION
FHWS FLATHEAD WOOD SCREW
FIN FINISH(ED)
FIXT FIXTURE
FJT FLUSH JOINT
FLCO FLOOR CLEANOUT
FLG FLASHING
FLR FLOOR
FLUR FLUORESCENT
FLX FLEXIBLE
FN FENCE
FNDN FOUNDATION
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUDS
FP FIRE PROTECTION
FP(G) FIREPROOF(ING)
FPL FLOOR PLATE
FR FRAME(D)(ED)
FRC FIRE-RESISTANT COATING
FRGD FORGED
FRPL FIREPLACE
FRT FIRE RETARDANT TREATED
FS FULL SIZE
FTG FOOTING
FURR FURRED, FURRING
FUT FUTURE
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GF GROUND FACE
GI GALVANIZED IRON
GKT GASKET
GL GLASS, GLAZING
GLB GLASS BLOCK
GLF GLASS FIBER
GP GALVANIZED PIPE
GPL GYPSUM LATH
GPPL GYPSUM PLASTER
GPT GYPSUM TILE
GRD GRADE, GRADING
GRN GRANITE
GRPG GLASS REINFORCED POLYMERIZED
GYPSUM
GSS GALVANIZED SHEET STEEL
GST GLAZED STRUCTURAL TILE
GT GROUT
GVL GRAVEL
GWB GYPSUM WALLBOARD
GYP GYPSUM
H/C HANDICAP(PED)
HB HOSE BIB
HBD HARDBOARD
HC HOLLOW CORE
HD HEAVY DUTY
HDNR HARDNER
HDR HEADER
HDWR HARDWARE
HES HIGH EARLY STRENGTH CEMENT
HH HANDHOLE
HJT HEADJOINT
HK(S) HOOK(S)
HM HOLLOW METAL
HORZ HORIZONTAL
HPT HIGH POINT
HR HOUR
HT HEIGHT
HTG HEATING
HVAC HEATING, VENTILATING AND AIR
CONDITIONING
HWD HARDWOOD
HWH HOT WATER HEATER
HX HEXAGONAL
ID INSIDE DIAMETER
ILK INTERLOCK
INCIN INCINERATOR
INCL INCLUDE(D), INCLUDING
INS INSULATE, INSULATION
INSC INSULATING, INSULATION
INSF INSULATING FILL
INT INTERIOR
INTM INTERMEDIATE
INV INVERT
IPS INTERIOR PAINT SYSTEM
JC JANITOR CLOSET
JF JOINT FILLER
JST JOIST
JT JOINT
KIT KITCHEN
KO KNOCKOUT
KPL KICKPLATE
L LENGTH
LAB LABORATORY
LAD LADDER
LAM LAMINATE (D)
LAV LAVATORY
LB LAG BOLT
LBL LABEL
LC LIGHT CONTROL
LCC LEAD COATED COPPER
LF LINEAR FOOT
LH LEFT HAND
LL LIVE LOAD
LMS LIMESTONE
LPT LOW POINT
LT LIGHT
LTL LINTEL
LVR LOUVER
LW LIGHT WEIGHT
LWC LIGHT WEIGHT CONCRETE
LWF LIGHT WEIGHT FILL
M METER(S)
MAS MASONRY
MAX MAXIMUM
MB MACHINE BOLT
MBR MEMBER
MC MEDICINE CABINET
MECH MECHANICAL
MED MEDIUM
MEP MECHANICAL ELECTRICAL AND PLUMBING
MET METAL
MFD METAL FLOOR DECKING
MFR MANUFACTURER
MH MANHOLE
MI MALLEABLE IRON
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING, MOULDING
MM MILLIMETER(S)
MMA MISC METAL ACCESSORY
MO MASONRY OPENING
MOD MODEL
MODU MODULAR
MOV MOVABLE
MR MOP RECEPTOR
MR GWB MOISTURE RESISTANT GWB
MT(D) MOUNT(ED)
MTHR METAL THRESHOLD
MTL MATERIAL
MULL MULLION
MWK MILLWORK
N NORTH
NAT NATURAL
NCX NONCOMBUSTIBLE EXTERIOR
NGVD NATIONAL GEOGRAPHICAL VERTICAL DATA
NI NICKEL
NIC NOT IN CONTRACT
NL NAILABLE
NNT NONMETALLIC
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COFFICIENT
NTS NOT TO SCALE
OA OVERALL
OBS OBSCURE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OHMS OVALHEAD MACHINE SCREW
OHWS OVALHEAD WOOD SCREW
OJ OPEN-WEB JOIST(S)
OP OPAQUE
OPN OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPS OPPOSITE SURFACE
PAR PARALLEL
PB PANIC BAR
PBD PARTICLE BOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PE PORCELAIN ENAMEL
PERF PERFORATED(D)
PERI PERIMETER
PFB PREFABRICATED
PG PLATE GLASS
PK PARKING
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLF POUNDS PER LINEAR FOOT
PLT PLATE
PNL PANEL
PNT(D) PAINT(ED)
POLY POLYETHYLENE
PR PAIR
PRF PREFORMED
PRN PREFINISH
PSC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTC POST TENSIONED CONCRETE
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PTR PAPER TOWEL RECEPTOR
PVC POLYVINYL CHLORIDE
PVG PAVING
PVMT PAVEMENT
PWD PLYWOOD
QT QUARREY TILE
R RISER
RA RETURN AIR
RAD RADIUS
RAG RETURN AIR GRILLE
RAI REMOTE ALARM INDICATOR
RB RUBBER BASE
RBS RUBBLE STONE
RBT RABBET
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RE REINFORCE(D), REINFORCING
REF REFERENCE
REG REGISTER
REM REMOVE
REQD REQUIRED
REQMT(S) REQUIREMENTS
RES RESILIENT
RET RETURN
RETG RETAINING
REV REVISION
RFG ROOFING
RFH ROOF HATCH
RFL REFLECT(ED)(IVE)(OR)
RH RIGHT HAND
RL RAIL(ING)
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RT RUBBER TILE
RTG RATING
RV ROOF VENT
RVS REVERSE SIDE
RVT RIVET
RWC RAINWATER CONDUCTOR
RWL RAINWATER LEADER
S SOUTH
SAB SOUND ATTENUATION BATT
SC SOLID CORE
SCH SCHEDULE
SCN SCREEN
SCT STRUCTURAL CLAY TILE
SD STORM DRAIN
SECT SECTION
SF SQUARE FOOT
SFGL SAFETY GLASS
SG SHEET GLASS
SH SHELF, SHELVING
SHO SHORE, SHORING
SHT SHEET
SHTH SHEATHING
SIM SIMILAR
SKLT SKYLIGHT
SL SLEEVE
SLNT SEALANT
SP SOUNDPROOF
SPC SPACER
SPEC(S) SPECIFICATION(S)
SPKR SPEAKER
SPL SPECIAL
SQ SQUARE
SSK SERVICE SINK
SSTL STAINLESS STEEL
STA STATION
STD STANDARD
STG SEATING
STL STEEL
STN STONE
STOR STORAGE
STR STRUCTURAL
SUS SUSPEND(ED)
SYM SYMMETRICAL
SYN SYNTHETIC
SYS SYSTEM
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T.O. TOP OF
TB TOWEL BAR
TC TERRA COTTA
TEL TELEPHONE
TEMP TEMPORARY
THK THICK(NESS)
THR THRESHOLD
TKBD TACKBOARD
TKS TACKSTRIP
TMPD TEMPERED
TOC TOP OF CURB
TOL TOLERANCE
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TP TACK PANEL
TPD TOILET PAPER DISPENSER
TPL TOP OF PLATE
TPTN TOILET PARTITION
TR TRANSOM
TSL TOP OF SLAB
TV TELEVISION
TW TOP OF WALL
TYP TYPICAL
UC UNDERCUT
UGD UNDERGROUND
UNF UNFINISHED
UNO UNLESS NOTED OTHERWISE
UR URINAL
VAR VARNISH
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VF VINYL FABRIC
VG VERTICAL GRAIN
VIF VERIFY IN FIELD
VIN VINYL
VJ V-JOINTED
VNB VINYL BASE
VNR VENEER
VRM VERMICULITE
VT VINYL TILE
VWC VINYL WALL COVERING
W WEST
W/ WITH
W/O WITHOUT
WB WOOD BASE
WC WATER CLOSET
WD WOOD
WG WIRE GLASS
WH WALL HUNG
WHB WHEEL BUMPER
WI WROUGHT IRON
WIN WINDOW
WM WIRE MESH
WP WATERPROOFING
WPT WORKING POINT
WR WASTE RECEPTACLE
WRP WATER REPELLANT
WS WATERSTOP
WS WEATHER STRIP
WSCT WAINSCOT
WTW WALL TO WALL
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
ZOL ZOLATONE
A6.1 ENLARGED PLANS, INTERIOR ELEVATIONS
AND DETAILS
A7.0 INTERIOR SCHEDULES AND
SPECIFICATIONS
Structural
S1.1 STEEL SUPPORT FOR ERV-1
Systems
E1 ELECTRICAL POWER PLAN
E2 ELECTRICAL LIGHTING PLAN
M0.00 MECHANICAL ABBREVIATIONS, NOTES, AND
SYMBOLS
MD1.00 MECHANICAL DEMOLITION PLANS
M1.00 MECHANICAL NEW WORK PLANS
M1.01 MECHANICALPLAN
M6.00 MECHANICAL SCHEDULE AND DETAILS
P1 PLUMBING PLAN
ANIMAL SHELTER RENOVATION
AND ADDITION
81 FOURNIER STREET
NEW HAVEN, CT
REMOVE DOOR AND
FRAME REMOVE OVERHEAD DOOR
REMOVE
STOREFRONT
WALL
REMOVE MID-HEIGHT WALL TO
MAKE AN OVERSIZE KENNEL
CUT OPENING
FOR DOOR
REMOVE CLOSET WALL
REMOVE TUB AND
CONCRETE BASE
REMOVE
CASEWORK
CUT OPENINGS
FOR DOORS
REMOVE CMU WALL AND DOOR
REMOVE PLUMBING
FIXTURES
REMOVE DOOR AND FRAME, CUT
CMU RETURN BACK FOR 42" CLEAR
HALLWAY
MAKE OPENING FOR NEW DOOR
REMOVE DOOR AND FRAME
REMOVE DOOR AND
FENCE TO MAKE AN
OVERSIZE KENNEL
HATCHING INDICATES AREA OF DENSE
VEGETATION TO BE CLEARED AS
NECESSARY TO COMPLETE WORK.
HATCH INDICATES
AREA WHERE
TRENCHING IS
NECESSARY FOR
SANITARY PIPING
HATCH INDICATES APPROXIMATE
AREA OF TRENCHING FOR
SANITARY PIPING, VIF
REMOVE
SECTION OF
FENCE
HATCH INDICATES APPROXIMATE
AREA OF TRENCHING FOR
SANITARY PIPING, VIF
REMOVE DOOR
PANELS, FRAMES
TO REMAIN
REMOVE WALLS, DOORS,
AND FIXTURES WITHIN LAV
REMOVE LOCKERS
REMOVE DOOR
PANEL, FRAME
TO REMAIN
REMOVE AND SALVAGE
EXISTING GROOMING TUB
FOR REUSE.
REMOVE DOOR PANEL.
DOOR FRAME TO REMAIN
REMOVE EXISTING CEILING
MOUNTED
RADIANT HEATERS (TYP)
REMOVE CEILING
MOUNTED
LIGHT FIXTURES (TYP)
REMOVE CEILING MOUNTED
LIGHT FIXTURE
REMOVE EXISTING SUPPLY AIR
REGISTERS (TYP)
REMOVE CEILING
MOUNTED
LIGHT FIXTURES (TYP)
REMOVE CEILING
MOUNTED
LIGHT FIXTURE
REMOVE CEILING MOUNTED
LIGHT FIXTURE
PROTECT EXISTING
DUCTWORK TO REMAIN, TYP
EXISTING EXPOSED
STRUCTURE AND LIGHT
FIXTURES TO REMAIN
EXISTING CEILING
GRID, MECHANICAL
UNIT, AND LIGHT
FIXTURES TO REMAIN
1. THIS DRAWING SHOWS GENERAL LAYOUT OF WALLS, COLUMNS, DOORS,
AND WINDOWS. DIMENSIONS ARE FOR REFERENCE ONLY. EXACT LOCATION,
SIZE, AND QUANTITY OF THESE ITEMS MAY DIFFER FROM THOSE INDICATED
ON PLANS.
2. DO NOT USE MOUNTED IMPACT HAMMERS, UNLESS NOTED OTHERWISE.
3. DO NOT REMOVE EXISTING ELECTRICAL AND FIRE ALARM FIXTURES,
CONDUIT, AND WIRING EXCEPT THOSE ATTACHED TO WALLS INDICATED TO
BE REMOVED.
4. DO NOT REMOVE EXISTING HVAC EQUIPMENT.
5. IN-HOUSE CITY STAFF WILL DISCONNECT UTILITIES AND TEMPORARILY SHUT
OFF AND DRAIN WATER FROM PLUMBING AND SPRINKLER SYSTEM AS
NECESSARY.
6. CAP AND MAKE SAFE AS NECESSARY EXISTING HVAC, GAS, PLUMBING
SUPPLY AND WASTE, FIRE PROTECTION, AND ELECTRIC LINES TO BE
ABANDONED BELOW EXISTING FLOOR.
7. PROVIDE BRACING AND/OR SHORING AS REQUIRED TO MAINTAIN ADEQUATE
SAFETY STANDARDS AND STRUCTURAL INTEGRITY OF THE BUILDING.
8. OVER DEMOLITION SHALL BE CORRECTED SUCH THAT SURFACES TO BE
REBUILT MATCH MATERIAL, STRUCTURAL INTEGRITY, AND APPEARANCE OF
THOSE THAT WERE REMOVED.
9. CONTRACTOR TO COORDINATE WITH THE CITY'S REPRESENTATIVE ITEMS TO
BE SAVED OR REUSED.
10. OBEY ALL CODES, STATUTES AND LAWS AS APPLICABLE TO DEMOLITION
WORK AND FOR REMOVAL OF MATERIAL, INCLUDING OSHA REGULATIONS.
11. DISPOSE OF ALL UNWANTED MATERIALS AND OTHER DEMOLITION DEBRIS
OFF SITE PER APPLICABLE CODES AND REGULATIONS. CONSTRUCTION
WASTE IS TO BE RECYCLED TO GREATEST EXTENT POSSIBLE.
12. COORDINATE THE EXACT LOCATION OF DUMPSTERS, CHUTES, AND
MATERIALS STORED AT GRADE (IF ANY) WITH THE CITY'S REPRESENTATIVE IN
THE FIELD, PRIOR TO PLACEMENT.
13. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY PARTITIONS/
CONSTRUCTIONS IN ORDER TO ISOLATE WORK ZONES AND MAINTAIN A
WEATHER-TIGHT BUILDING.
14. REMOVE ALL LIGHT FIXTURES AND CONTROLS EXCEPT FOR MECHANICAL
ROOM, JANITOR CLOSET, UTILITY ROOM AND RECEPTION AND PERSONNEL
ROOMS WHERE LIGHT FIXTURES ARE INDICATED TO REMAIN.
GENERAL REMOVAL NOTES
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
As indicated
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK
REMOVAL PLAN
R1.1
BID SET
1/8" = 1'-0"
REMOVAL PLAN
2 ADDENDUM #4 6/23/26
R E
F
CODE PLAN LEGEND
XX
XXX
ACTUAL DISTANCE
EXIT TRAVEL DISTANCE
ALLOWABLE DISTANCE
TRAVEL
DIRECTION
XX
XXX
ACTUAL
OCCUPANT
LOAD
EXIT CAPACITY
ALLOWABLE
OCCUPANT LOAD
AREA NAME
### ##### SFX
AREA NUMBER
AREA SQUARE FOOTAGE
USE GROUP
OCCUPANCY FACTOR
NUMBER OF OCCUPANTS
OCCUPANCY TAG
AREA BOUNDARY
1 HR RATED CORRIDOR WALL
CODE INFORMATION TABLE
CONSTRUCTION TYPE TYPE III-B
SPRINKLERS NOT REQUIRED
AVERAGE HEIGHT ABOVE GRADE 12' - 9"
ALLOWABLE HEIGHT 55' - 0"
STORIES ABOVE GRADE 1
ALLOWABLE STORIES
BUILDING AREA 5,376 SF
BASE ALLOWABLE AREA
EXISTING: NO RATING
ADDITION: 1HR
FIRE RATING: EXIT ACCESS CORRIDORS
LEVEL OF PROPOSED ALTERATIONS LEVEL 3/ ADDITION
COMMON PATH OF TRAVEL MAX
DEAD END CORRIDOR MAX EXISTING: 50 FT
ADDITION: 20 FT
CODE
REFERENCE
CSBC TABLE 504.3
CSBC TABLE 504.4
CSBC TABLE 506.2
CSFC IV.7.1.3.1(1)
CSBC TABLE 1020.2
CSFC IV 39.2.5.2.2
CSBC TABLE 1006.2.1
CSFC IV 39.2.5.3
CSBC 1020.5
IEBC 604/ 606
EXIT TRAVEL DISTANCE MAX CSFC 39.2.6.2
CSBC TABLE 1017.2
INTERIOR FINISH CLASSES CSBC TABLE 803.13
GROUP B
19,000 SF
200 FT
75 FT
CORRIDORS: B
CORRS/ ROOMS: C
• 2022 Connecticut State Building Code based on the following International Code Council references with CT amendments.
• 2021 International Building Code (CSBC)
• 2021 International Existing Building Code (IEBC)
• 2021 International Plumbing Code (IEPC)
• 2021 International Mechanical Code (IEMC)
• 2021 International Energy Conservation Code (IECC)
• 2020 National Electrical Code (NFPA 70)
• 2017 ICC A117.1 Accessible and Usable Buildings & Facilities
• 2022 Connecticut State Fire Safety Code (CSFC) Part IV for existing buildings based on the following National Fire Protection Code with CT amendments:
• 2021 NFPA 101 Life Safety Code
APPLICABLE BUILDING AND FIRE CODES
COMPONENT
MIN THERMAL
VALUE
ROOF - INSULATION ENTIRELY ABOVE DECK R-30 ci
WALLS, ABOVE GRADE - MASS
WALLS, BELOW GRADE
SLAB-ON-GRADE FLOORS - UNHEATED
ENTRANCE DOORS
SKYLIGHTS
SHGC MAX
BUILDING ENVELOPE REQUIREMENTS, R-VALUE-BASED METHOD
R-11.4 ci
R-7.5 ci
R-15 FOR 24"
BELOW
U-0.63
U-0.50 SHGC-0.40
1477 SF
EXISTING REAR
100 14.8B
658 SF
ADDITION
100 6.6B
108 SF
DISINFECTION
293 SF
KENNEL ROOM 1 (10)
342 SF
INTAKE KENNELS (10)
199 SF
MEDICAL ISOLATION
(6)
91 SF
STORAGE/
INCINERATOR
129 SF
CATTERY INTAKE
72 SF
CAT ISOLATION
83 SF
LAUNDRY82 SF
UTILITY
132 SF
GROOMING
82 SF
STAFF LAV
350 SF
KENNEL ROOM 4 (9)
283 SF
KENNEL ROOM 3 (8)
515 SF
KENNEL ROOM 2 (14)
104 SF
PERSONNEL
96 SF
RECEPTION
292 SF
ENTRY
73 SF
VISITOR DEN
173 SF
CATTERY
46 SF
ADA LAV
139 SF
BREAK ROOM
87 SF
MECH
21 SF
CLOSET
1125 SF
OUTDOOR COURTYARD
123 SF
DISHES
193 SF
VETERINARY
92 SF
DISINFECTION
243 SF
STORAGE
1180 SF
EXISTING KENNEL SOUTH
100 11.8B
50 FT
200 FT
F
T
FT
15 12
267 SF
EXISTING OFFICE SOUTH
100 2.7B
1012 SF
EXISTING OFFICE NORTH
100 10.1B
781 SF
EXISTING KENNEL NORTH
100 7.8B
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
As indicated
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK
CODE SHEET
A0.1
BID SET
PLUMBING FIXTURES
GROUP OL
MWC FWC LAVORATORIES DRINKING FOUNTAIN SERVICE SINK
REQ'D PROVIDED REQ'D PROVIDED REQ'D PROVIDED REQ'D PROVIDED REQ'D PROVIDED
B 53.8 1.1 1 1.1 1 1.3 6 0.5 1 1 1
1/8" = 1'-0"
AREA FLOOR PLAN
OCCUPANCY AREA SCHEDULE (REAR ADDITION)
NAME AREA GROUP FUNCTION
LOAD
FACTOR
OCCUPANT
LOAD
ADDITION 658 SF B Business Areas 100 6.6
EXISTING KENNEL NORTH 781 SF B Business Areas 100 7.8
EXISTING KENNEL SOUTH 1180 SF B Business Areas 100 11.8
EXISTING OFFICE NORTH 1012 SF B Business Areas 100 10.1
EXISTING OFFICE SOUTH 267 SF B Business Areas 100 2.7
EXISTING REAR 1477 SF B Business Areas 100 14.8
Grand total: 6 5376 SF 53.8
N
THIS FACILITY MOSTLY CONSISTS OF KENNELS, AND IS NOT ANTICIPATED TO EVER HAVE MORE THAN 15 PEOPLE INCLUDING EMPLOYEES AND VISITORS.
IBC 2902.2 Separate facilities shall not be required in structures or tenant spaces with a total occupant load including both employees and customers of 15, or fewer. Animal hospital, kennels and pounds are considered a B Business Use. Table 2902.1 combines the Men and Woman together for 1 per 25 for the first 50. One Bathroom with a toilet and lavatory will suffice.
STUD PARTITION WALL - STC 44
P4A
3 5/8" METAL STUDS @ 16" O.C., TIGHT TO DECK ABOVE,
3 1/2" SOUND ATTENUATION BLANKET BETWEEN STUDS.
(1) LAYER 5/8", GWB ON EACH SIDE
MASONRY PARTITION WALL
M6A
NOMINAL 6" CMU
P4=3 5/8" METAL STUDS @ 16" O.C.
P6=6" METAL STUDS @ 16" O.C.
3 1/2" SOUND ATTENUATING
BATT INSULATION
(1) ONE LAYER OF 5/8"
G.W.B., EACH SIDE
FINISHED FLOOR AND BASE AS
SCHEDULED, BOTH SIDES
4 7/8"
PARTITION TYPE GENERAL NOTES
1. SEE FINISH SCHEDULE FOR INTERIOR FINISH AND GYPSUM BOARD
TYPE AND OTHER SUBSTRATE INFORMATION.
2. SEE FINISH SCHEDULE FOR WHERE TILE IS APPLIED, AND INTERIOR
ELEVATIONS TO SEE EXTENT, PROVIDE SPECIFIED TILE BACKER
BEHIND TILE.
3. PERIMETER OF GYPSUM BOARD SHALL BE HELD OFF ADJACENT
SURFACES 3/8" AND JOINT FILLED WITH ACOUSTIC SEALANT.
4. PROVIDE ALL NECESSARY CAULKING, ETC. AT EQUIPMENTS,
DEVICES, OUTLETS, BOXES, ETC. IN ORDER TO MAINTAIN SOUND,
AIR, AND THERMAL SEPARATIONS. DO NOT INSTALL BACK-TO-BACK
BOXES.
5. PROVIDE SOUND ATTENUATION BLANKET AT ALL STUD PARTITIONS,
TYPICAL.
6. PROVIDE 6" W 16 GA GALV. MTL BACK UP PLATES IN STUD WALLS OR
WOOD BLOCKING TO ALLOW FOR THE ANCHORAGE OF ALL MISC.
ITEMS TO THE WALL SUCH AS, BUT NOT LIMITED TO SHELVING,
CABINETS, DOOR STOPS, TOILET ACCESSORIES & ANY OTHER WALL
ATTACHMENT REQUIRING SUPPORT.
7. PROVIDE FIRE-RESISTANT TREATED (FRT) PLYWOOD BACKBOARDS
AT ELECTRICAL AND TELECOM ROOMS. ALL PLYWOOD BACKER-
BOARDS, FURRING AND CLEATS ASSOCIATED WITH WOOD
PANELING TO BE FRT.
8. PROVIDE ACCESS PANELS AS REQUIRED. FINISH TO MATCH
ADJACENT SURFACE AND LOCATE TO REDUCE VISIBILITY.
9. ALL GYPSUM BOARD TO RECEIVE LEVEL 4 FINISH UNLESS NOTED
OTHERWISE.
STUD INFILL PARTITION WALL - STC 44
P4B
3 5/8" METAL STUDS @ 16" O.C., WITHIN OPENING
3 1/2" SOUND ATTENUATION BLANKET BETWEEN STUDS.
(1) LAYER 5/8", GWB ON EACH SIDE
4 7/8"
USE A DEFLECTION TRACK AT
THE TOP OF THE WALL, SEAL
WITH ACOUSTIC SEALANT
GRAY HATCH INDICATES
EXISTING CONSTRUCTION, VIF
MASONRY PARTITION WALL
M8B
NOMINAL 8" CMU
M6 = 6" CMU
M8 = 8" CMU
M8=7 5/8" M6= 5 5/8"
MASONRY INFILL PARTITION WALL
M6B
NOMINAL 6" CMU
6" CMU
MATCH EXISTING REBAR
SPACING #4 AT 16" O-C
AND FILL W/ GROUT
5 5/8"
MASONRY INFILL PARTITION WALL
M8C
NOMINAL 8" CMU
MASONRY LOAD BEARING WALL - 1 HR RATED
M8A
NOMINAL 8" CMU
UL DESIGN NO. U906
SEE A4.0 WALL SECTIONS FOR FURTHER DETAIL
EXTEND TO BOTTOM OF THE DECK
COMPRESSIBLE ISOLATION JOINT AT
TOP OF INFILL WALLS & LATERAL
RESTRAINT BRACKET.
STUD PARTITION WALL - STC 44
P6
6" METAL STUDS @ 16" O.C., TIGHT TO DECK ABOVE,
3 1/2" SOUND ATTENUATION BLANKET BETWEEN STUDS.
(1) LAYER 5/8", GWB ON EACH SIDE
GRAY HATCH INDICATES
EXISTING CONSTRUCTION
8" CMU
7 5/8"
GRAY HATCH INDICATES
EXISTING CONSTRUCTION, VIF
7'
3/
8"
V
IFA
D
D
IT
IO
N
8'
-9
/4
E X
IS
TI
N G
/2
V
IF
SLAB-ON-GRADE
BOTTOM OF
ROOF DECK
MASONRY INFILL EXTERIOR WALL
M8E
NOMINAL 8" OMNI BLOCK
8" OMNI BLOCK
7 5/8"
9'
1/
2"
V
IF
SLAB-ON-GRADE
BOTTOM OF
ROOF DECK
GRAY HATCH
INDICATES EXISTING
CONSTRUCTION, VIF
MASONRY INFILL EXTERIOR WALL
M8D
NOMINAL 8" OMNI BLOCK
NOMINAL 8" X 8" X 4" GLASS BLOCK
8" OMNI BLOCK
GRAY HATCH
INDICATES EXISTING
STEEL LINTEL, VIF
V
IF
8'
1/
2"
V
IFPAINTED
WOOD SILL
EXTERIORINTERIOREXTERIORINTERIOR
PAINTED WOOD TRIM
1 1/2" RIGID INSULATION,
WRAP LINTEL STRUCTURE
4" GLASS BLOCK
7 5/8"
2 1/2" COLD FORMED METAL SOFFIT
ACOUSTIC PANEL CEILING
STUD PLUMBING LINER WALL - EXTERIOR TILED
P4C
1 3/4" RIGID INSULATION (POLYISO) R=11.4
3 5/8" METAL STUDS @ 16" O.C., TIGHT TO DECK ABOVE
SMART VAPOR RETARDER
(1) LAYER 1/2", CEMENT BOARD ON INTERIOR SIDE
FULL HEIGHT TILE
STUD PLUMBING LINER WALL - EXTERIOR
P4D
3 5/8" METAL STUDS @ 16" O.C.
1/2" CEMENT BOARD
FULL HEIGHT TILE
1 3/4" RIGID INSULATION
(POLYISO)
SMART VAPOR RETARDER
1 3/4" RIGID INSULATION (POLYISO) R=11.4
3 5/8" METAL STUDS @ 16" O.C., TIGHT TO DECK ABOVE
SMART VAPOR RETARDER
STUD PLUMBING LINER WALL
P4E
3 5/8" METAL STUDS @ 16" O.C., TIGHT TO DECK ABOVE
STUD PLUMBING LINER WALL - TILED
P4G
3 5/8" METAL STUDS @ 16" O.C., TIGHT TO DECK ABOVE
(1) LAYER 1/2", CEMENT BOARD ON INTERIOR SIDE
FULL HEIGHT TILE
BY TYPE
VARIES
STUD PARTITION WALL - 1 HR RATED
P4F
3 5/8" METAL STUDS @ 16" O.C., TIGHT TO DECK ABOVE,
3 1/2" SOUND ATTENUATION BLANKET BETWEEN STUDS.
(1) LAYER 5/8", GWB ON EACH SIDE
UL DESIGN NO. U419
MASONRY GENERAL NOTES
1. ALL MASONRY WALLS LAID IN RUNNING BOND.
2. COMPRESSIBLE ISOLATION JOINT & LATERAL RESTRAINT BRACKET
AT TOP OF INFILL WALLS.
3. CLEAN AND SCORE EXISTING CONCRETE SLAB IN FOOTPRINT OF
NEW PARTITION WALL, SET WALL IN MORTAR BED.
4. USE F'M MIN OF 2500 PSI TYPE M PORTLAND CEMENT/LIME MORTAR
FULL BED/HEAD
5. ANCHOR AT WALL INTERSECTIONS WITH EXISTING MASONRY WALLS
USING JOINT REINFORCEMENT 1/4" GALV MESH CLOTH AT 16" O-C
VERTICALLY
6. #4 BAR VERTICALLY AT 48" O.C. AT ENDS OF IN-FILL WALL
7. FOR DUCT OPENINGS REFER TO LINTEL SCHEDULE, AND REFER TO
SHEET M1.01 FOR LOCATIONS.
TYPE M PORTLAND
CEMENT/LIME MORTAR
FULL BED/HEAD. 1/4"
GALV MESH LADDER
REINFORCEMENT
HORIZONTAL AND VERTICAL 3/8"
COMPRESSIBLE ISOLATION JOINT
AROUND PERIMETER OF INFILL WALL.
1/2"X6"X6" PLT SPACED AT 3' O-C
BETWEEN TOP OF INFILL WALL AND
EXISTING WALL ANCHOR INTO EXISTING
CMU WITH (2) 1/2" DIA HEADED STUDS
W/ WASHER AND DOUBLE NUT
GALVANIZED CX9 A36,
FILLET WELD ALONG BOTH
LEGS TO BOTTOM FLANGE
OF EXISTING BEAM
1. SET GAUGE 16 CHANNEL 5" DEEP
ALONG BOTH ENDS.
2. COAT BASE WITH WATERPROOFING
BEFORE LAYING FIRST COURSE.
3. USE TYPE S OR N MORTAR AND W1.7
JOINT REINFORCEMENT AT 16" O-C
VERTICALLY.
4. LAY EXPANSION STRIP OF 3/8"
VERTICALLY AT ENDS AND
HORIZONTALLY ON TOP WITH
SEALANT. REFER TO GENERAL NOTES ON SHEET A1.1
GYPSUM BOARD
1. INTERIOR GYPSUM BOARD
A. USG SHEETROCK ECOSMART GYPSUM PANEL
FIRECODE X
B. THICKNESS: 5/8 INCH
2. MRGWB: MOLD RESISTANT GYPSUM BOARD
A. USG SHEETROCK ECOSMART GYPSUM PANEL MOLD
TOUGH FIRECODE X
B. THICKNESS: 5/8"
3. TBGWB: TILE BACKER GYPSUM BOARD
A. USG DUROCK BRAND CEMENT BOARD WITH
EDGEGUARD
B. THICKNESS: 1/2"
PLYWOOD
1. PWD: 1/2" FIRE TREATED PLYWOOD
SMART VAPOR RETARDER
1. BASIS OF DESIGN: PRO CLIMA INTELLO PLUS
RIGID INSULATION (POLYISO)
1. BASIS OF DESIGN: RMAX THERMASHEATH
2. THICKNESS: 1 3/4"
3. R-VALUE: R-11.4
4. TAPE SEAMS AND USE TAPE OR CLOSED-CELL SPRAY TO
SEAL TO ADJACENT SURFACES
PARTITION SPECIFICATIONS
LINTEL OPTIONS
DOOR # PRECAST (2) L ANGLES WT SHAPE
122A
122B
140A
140B
X X
X XX
X XX
X XX
X XX
X XX
X XX
X XX
X XX
X XX
X XX
LINTEL GENERAL NOTES:
1. ALL LINTELS TO BEAR ON 8" OF SOLID BLOCK
2. CONTRACTOR TO SUBMIT FOR APPROVAL DEMO AND
SHORING NARRATIVE/SCHEME FOR INSTALATION OF
LINTELS IN NEW OPENINGS.
OPTION 1: PRECAST LINTEL
5/
8"
7 5/8"
2"
2"
1. SET IN MORTAR BED
2. STEEL REINFORCEMENT TO BE GRADE 60
3. 2" CLEAR COVER TO REINFORCEMENT ALL AROUND,
EXCEPT AS NOTED
4. CONCRETE TO HAVE MIN. COMPRESSIVE STRENGTH F'C
3000 PSI
5. SUBMIT MIX DESIGN FOR APPROVAL
OPTION 2: (2) L ANGLES
1. CUT BLOCK TO FIT
2. SET IN MORTAR BED
3. STEEL TO BE HOT-DIPPED GALVANIZED
4. ANGLES TO BE GRADE A36 STEEL
5 5/8"7 5/8"
OPTION 3: WT SHAPE
1. CUT BLOCK TO FIT
2. SET IN MORTAR BED
3. STEEL TO BE HOT-DIPPED GALVANIZED
4. WT SHAPE TO BE GRADE A36 STEEL
5 5/8"
5/
8"
5 5/8"
1 1/2"
2"
7 5/8"
(2) 3x3x3/8
L ANGLES
(1) 3x3x3/8 +
(1) 3X2X3/8
L ANGLES
WT5X15 WT8X13
LINTEL FOR DUCT OPENING ABOVE DOOR 141
1. CUT BLOCK TO FIT
2. SET IN MORTAR BED
3. STEEL TO BE HOT-DIPPED GALVANIZED
4. W SHAPE TO BE GRADE A36 STEEL
WT8X35
SECTION
ELEVATION
ENDCASE END 8" OF
LINTEL IN GROUT AND 8"
BEARING UNDER GIRDER
DUCT
OPENING
PRECAST (2) L ANGLES WT SHAPE
8"
OVER DOOR 141
138 -> 139 X XX
SEE ABOVE
139 -> 138 X XX
FOR ALL DUCT OPENINGS THROUGH NONBEARING MASONRY WALLS,
UNLESS OTHERWISE NOTED ON SHEET M1.01, REMOVE THE TOP
COURSE PARTITION AS NEEDED. DO NOT CUT JOISTS.
** IT CAN CAUSE A SUDDEN AND CATASTROPHIC FAILURE OF THE PLANK IF
STRANDS ARE CUT IN THE WRONG PLACE.
NOTES FOR ATTACHING TO PC PT HOLLOWCORE PLANKS
1. MAKE ANY OPENINGS/PENETRATIONS USING PERCUSSION ONLY
DRILL METHOD
2. PENETRATIONS AND ATTACHMENTS MAY ONLY BE 1 1/2" DEPTH
3. SCAN SYSTEM SHOULD BE EMPLOYED PRIOR START OF WORK TO
FIELD LOCATE TENSIONED WIRE STRANDS WITHIN 2’ RADIUS OF ALL
PROPOSED PENETRATIONS
4. MARK OUT ALL OPENINGS/PENETRATIONS FOR APPROVAL BY
ENGINEER PRIOR TO BEGINNING WORK
5. IF MULTIPLE HOLES ARE NECESSARY THEY SHOULD BE ALIGNED AND
SPACED 1.5D – 3D EDGE TO EDGE
6. CONTRACTOR MUST SUBMIT ATTACHMENT POINTS AND FASTENING
SYSTEM DESIGNED FOR MINIMUM PENETRATION INTO HOLLOWCORE
PLANKS SUCH AS DROP IN OR FLUSH ANCHORS BY HILTI
7. APPROXIMATE DISTRIBUTION OF PT STRANDS IS 1 1/2" ADN 8 1.2"
FROM EDGE OF BEAM.
ATTACHMENT TO STRUCTURAL CONCRETE CEILING PLANKS
CHASING LATERALLY ACROSS BUILDING
** DO NOT MAKE HOLES THROUGH MASONRY WALLS OR CONCRETE PLANKS
BEFORE APPROVAL FROM ENGINEER.
** CONFIRM STRATEGY FOR SYSTEM DISTRIBUTION BEFORE
COMMENCEMENT OF WORK.
NOTES ABOUT CHASING THROUGH MASONY WALLS:
1. CONTRACTOR MUST SUBMIT ALL OPENINGS IN MASONRY WALLS TO
BE APPROVED BEFORE COMMENCEMENT OF WORK.
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
As indicated
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK/ ZS
PARTITION TYPES AND LINTELS
A0.2
BID SET
3/4" = 1'-0"
PARTITION TYPES
1 1/2" = 1'-0"
LINTEL INFORMATION
F
INFILL WALL
WALL TO CREATE
CAT ISOLATION
ROOM
INFILL WITH WALL AND
MAN DOOR
4FT HIGH GALVANIZED
CHAINLINK FENCE
WITH OPAQUE NYLON
NETTING ACCESS
GATES AT EITHER
END.
S
TO
R A
G E
INFILL OPENING WITH A CMU & GLASS
BLOCK WALL
NEW DOOR IN EXISTING WALL.
ALIGN WITH MASONRY COURSING
HATCH INDICATES
700 SF ADDITION
KENNEL ROOM 1 (10)
INTAKE KENNELS (10)
MEDICAL ISOLATION
(6)
STORAGE/
INCINERATOR
CATTERY INTAKE
CAT ISOLATION
LAUNDRY
UTILITY
GROOMING
STAFF LAV
KENNEL ROOM 4 (9)
KENNEL ROOM 3 (8)
KENNEL ROOM 2 (14)
PERSONNEL
RECEPTION
ENTRY
VISITOR DEN
CATTERY
ADA LAV
110B
HALL
BREAK ROOM
MECH
CLOSET
OUTDOOR COURTYARD
DISHES
DISINFECTION
STORAGE
VETERINARY
DISINFECTION
A6.1
C6
110A
HALL
HALL
A6.1
G3
134A
140C140A
G4
A4.1
EXISTING
GAS
METER
INSTALL NEW FENCE SECTION
TO REPLACE REMOVED DOOR
OUTDOOR KENNEL
AREA 4
OUTDOOR KENNEL
AREA 1
OUTDOOR KENNEL
AREA 2
OUTDOOR KENNEL
AREA 3
M8-A
2'
6" 3'
4"
P4A
P6
M8-B
M8-C
M6-A
G3
A4.2
P4B
P4F
M8-D
M8-E
8" 40" 38"
86"
ELECTRICAL SERVICE
CONDUIT UNDERGROUND
PROTECT
EXISTING TREE
A6.1
G1
TA.13
TA.12
P4 C
P4 D
P4 E
P4 G
P4 G
NEW FENCE AND GATE
MATCH EXISTING 6'-6" HIGH
GALVANIZED CHAIN LINK
FENCE WITH AN
ADDITIONAL 2FT OF CANTED
BARB WIRE ON TOP.
TA.01
TA.06
W/D W/D
PROVIDE CLEARANCE
BEHIND MACHINES
1/4" EXPANSION JOINT
FULL HEIGHT BETWEEN
CIPC FOOTING/WALL
AND EXISTING
STRUCTURE
1/4" EXPANSION JOINT FULL HEIGHT
BETWEEN CIPC FOOTING/WALL AND
EXISTING STRUCTURE
TIE NEW PERIMETER DRAINS INTO
EXISTING PERIMETER DRAINS, MATCH
PITCH OF EXISTING, VIF
REGRADE TO ACHEIVE MIN
2% SLOPE FROM BUILDING
HATCH INDICATES
AREA OF NEW
CONCRETE SLAB,
TYP
36"
36"
36"
36"
HATCH
INDICATES
AREA OF NEW
CONCRETE
SLAB, TYP
HATCH
INDICATES
AREA OF NEW
CONCRETE
SLAB, TYP
D1
A5.0
TYP
D1
A5.0
TYP
D1
A5.0
TYP
140A
VESTIBULE
WALK-OFF
MAT
G1
A3.0
140B
SALVAGED
GROOMING TUB
PATCH AND BLEND EPOXY FLOOR TO
MATCH WHERE WALL WAS REMOVED
GENERAL NOTES
1. CONTRACTOR IS TO FULLY FAMILIARIZE THEMSELVES WITH THE
GENERAL CONDITIONS POSTED ON THE CITY OF NEW HAVEN'S
PURCHASING DIVISION WEBSITE WHICH THOROUGHLY DEFINES
PROJECT PROCESS AND PERFORMANCE REQUIREMENTS.
2. DRAWINGS SHOW GENERAL LAYOUT OF EXISTING CONDITIONS.
DIMENSIONS ARE FOR REFERENCE ONLY. EXACT LOCATION, SIZE,
AND QUANTITY OF THESE ITEMS MAY DIFFER FROM THOSE
INDICATED ON PLANS.
3. THE INFORMATION CONTAINED WITHIN THE CONTRACT
DOCUMENTS IS MEANT TO CONVEY THE DESIGN INTENT. IT IS NOT
MEANT TO BE EXHAUSTIVE IN SCOPE NOR TOTALLY
COMPREHENSIVE IN DETAIL. REPETITIVE FEATURES MAY BE
DRAWN ONLY ONCE, BUT SHALL BE PROVIDED AS IF DRAWN IN
FULL.
4. IN THE EVENT OF A CONFLICT WITHIN THE CONTRACT
DOCUMENTS, THE MOST STRINGENT OBLIGATION OR DUTY AND
THE HIGHEST QUALITY OR GREATEST QUANTITY SHALL CONTROL.
5. PROTECT EXISTING CONSTRUCTION TO REMAIN INCLUDING, BUT
NOT LIMITED TO, STRUCTURE, WALLS, GLAZING, FLOORING, AND
ROOF DRAINS.
6. IN-HOUSE CITY STAFF WILL DISCONNECT UTILITIES AND
TEMPORARILY SHUT OFF AND DRAIN WATER FROM PLUMBING AND
SPRINKLER SYSTEM AS NECESSARY.
7. DAMAGE TO EXISTING CONSTRUCTION SHALL BE CORRECTED
SUCH THAT SURFACES TO BE REBUILT MATCH MATERIAL,
STRUCTURAL INTEGRITY, AND APPEARANCE OF THOSE THAT WERE
REMOVED.
8. COORDINATE THE EXACT LOCATION OF DUMPSTERS, CHUTES,
AND MATERIALS STORED AT GRADE (IF ANY) WITH THE CITY'S
REPRESENTATIVE IN THE FIELD PRIOR TO PLACEMENT.
9. CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY PARTITIONS/
CONSTRUCTIONS IN ORDER TO ISOLATE WORK ZONES AND
MAINTAIN A WEATHER-TIGHT BUILDING.
10. ALL SPECIFICATIONS ARE BASIS OF DESIGN. REFER TO THE
GENERAL CONDITIONS "OR EQUAL" CLAUSE FOR CLARIFICATION.
11. SUBMIT CUT SHEETS AND SHOP DRAWINGS OF MATERIALS PRIOR
TO PURCHASE.
12. PROVIDE MATERIALS AND ACCESSORIES AS REQUIRED TO
PROVIDE A COMPLETE INSTALLATION.
13. PROVIDE MANUFACTURER'S STANDARD WARRANTY FOR ALL
PRODUCTS USED ON THE PROJECT AND TURN OVER
DOCUMENTATION INCLUDING USE AND MAINTENANCE MANUALS.
14. ACQUIRE MATERIALS FROM A SINGLE SOURCE AS MUCH AS
POSSIBLE FOR EASE OF MAINTENANCE AND WARRANTY.
15. FOLLOW MATERIAL MANUFACTURER'S RECOMMENDED
INSTALLATION PRACTICES.
16. DIMENSIONS ON PLANS ARE TYPICALLY TO FACE OF WALL OR
MASONRY, AND TO FACES OF FINISHES FOR INTERIOR PARTITIONS,
UNLESS OTHERWISE SHOWN OR NOTED.
17. CONTRACTOR MUST OBTAIN ANY/ALL NECESSARY PERMITS FOR
WORK. CONTRACTOR MUST SELECT “PAY AT COUNTER” SO THAT
THE BUILDING DEPARTMENT CAN WAIVE/ADJUST THE
MUNICIPALITY PERMIT FEE. THE CONTRACTOR WILL THEN RECEIVE
AN EMAIL FOR THE ADJUSTMENT AND BE ABLE TO LOG-IN TO PAY
JUST THE STATE PERMIT FEE.
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
As indicated
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK
FLOOR PLAN
A1.1
BID SET
1/8" = 1'-0"
FLOOR PLAN
N
G4
A4.1
1/ 4"
EXISTING
SCUPPER
REMOVE EXISTING
SCUPPER, FENCING, AND
PARAPET FLASHING AND
INSTALL PER DETAIL
SINGLE-PLY
MEMBRANE ROOF
REMOVE SECTION OF
EXISTING GUTTER
EXISTING
EPDM ROOF
EXISTING
EPDM ROOF
EXISTING
FIBERGLASS
ROOF
EXISTING
FIBERGLASS
ROOF
EXISTING
FIBERGLASS
ROOF
EXISTING
FIBERGLASS
ROOF
EXISTING
EPDM ROOF
EXISTING
EPDM ROOF EXISTING
EPDM ROOF
EXISTING
EPDM ROOF
GRAY HATCH
INDICATES EXISTING
ROOF TO REMAIN
EXISTING GUTTER
TO REMAIN, TYP
EXISTING
PARAPET
AND FENCE
G3
A4.2 A3.0
C5
A3.0 E5
EXTEND EXISTING
WALL UP TWO
COURSES OF CMU
ADD A SPOUT FROM
GUTTER ONTO
FIBERGLASS ROOF
START PARAPET FENCE
TIE INTO EXISTING
END PARAPET FENCE
ABOVE FENCE BELOW
11' - 9 1/2" 17' - 11 3/4" 13' - 4 1/8"
1/2"
1/2"
1/2" 1/2"
1/ 4"
1/2" 1/2"
C
LE
A R
95"
G1
A3.0
SCUPPER
SCUPPER PARAPET
ROOF TOP UNIT, PROVIDE A 24" HIGH
CURB AND USE A PIPE PORTAL SYSTEM
TO FLASH PIPE PENETRATIONS
PLUMBING VENT
SEE DETAIL
ROOFTOP UNIT, PROVIDE A 24" HIGH
CURB, AND A PIPE PORTAL SYSTEM TO
FLASH PIPE PENETRATIONS.
/G1 A5.0
1/2" SLOPE
CRICKET IN
CORNER
GENERAL NOTES:
1. ACQUIRE MATERIALS AND ACCESSORIES FROM A SINGLE-
SOURCE AS REQUIRED TO PROVIDE A COMPLETE
INSTALLATION.
2. INSTALLATION AS RECOMMENDED BY THE MANUFACTURER
TO ACHIEVE WARRANTY
3. CUT AND PATCH EXISTING ROOF AS REQUIRED TO COMPLETE
THE WORK. THE EXISTING EPDM ROOF WAS INSTALLED IN
2007. THE ROOF SYSTEM MANUFACTURER IS UNKNOWN.
VERIFY MANUFACTURER IN THE FIELD AND MAINTAIN THE
WARRANTY.
SINGLE-PLY ROOF MEMBRANE
1. FULLY ADHERED .090" UNREINFORCED EPDM
A. CLASS A FIRE RATING
B. FM I-90 WIND STORM RATING
C. 30 YEAR LABOR AND MATERIAL WARRANTY
ROOF INSULATION
1. POLYISOCYANURATE ROOF INSULATION
A. 2 LAYERS
B. NO LAYER THICKER THAN 2 1/2"
C. C1289, TYPE II, CLASS 1 GRADE 3
D. 25PSI MINIMUM COMPRESSIVE STRENGTH
E. COATED GLASS FACERS ON BOTH SIDES
2. HI-DENSITY POLYISOCYANURATE COVER BOARD
A. C1289, TYP II, CLASS 4, GRADE 2
B. 110 PSI MINIMUM COMPRESSIVE STRENGTH
VAPOR RETARDER
1. PEEL AND STICK MEMBRANE SELF-SEALING TO FASTNER
PENETRATIONS AS SUPPLIED BY PRIMARY ROOF
MANUFACTURER.
ROOF ROUGH CARPENTRY
1. PRESSURE TREATED BLOCKING
A. ALKALINE COPPER QUARTERNARY (ACQ)
B. MOISTURE CONTENT: 15% MAX
2. FASTENERS
A. CORROSION RESISTANT
B. SUITABLE FOR APPLICATION
FLASHING AND SHEET METAL
1. FLASHING
A. ASTM B209 ALUMINUM
2. GUTTER
A. SIZE: 6"
B. 0.032" ALUMINUM
C. CONCEALED HANGERS
D. END CAPS
3. DOWNSPOUTS
1. 3X4 PREFINISHED .032" CORRUGATED ALUMINUM
4. COPING
A. STYLE: PREFORMED SLOPED COPING AND/OR AS
RECOMMENDED BY ROOFING MANUFACTURER TO
MAINTAIN WARRANTY.
B. SIZE: VIF
C. 0.05" ALUMINUM
5. PREFINISH
1. COLOR: DARK BRONZE
ROOF SPECIFICATIONS
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
As indicated
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK
ROOF PLAN AND SPECIFICATIONS
A1.2
BID SET
N
1/8" = 1'-0"
ROOF PLAN
1 EXISTING ROOF WARRANTY 6/2/26
A4.1
G3
A4.2
2' x 4' ACT System + 7' - 6" A.F.F.
2' x 4' ACT System + 7' - 6" A.F.F.
2' x 4' ACT System + 8' - 0" A.F.F.
2' x 2' ACT System + 7' - 6" A.F.F.
2' x 2' ACT System + 7' - 6" A.F.F.
2' x 4' ACT System + 8' - 0" A.F.F.
2' x 4' ACT System + 8' - 0" A.F.F.
GWB
+ 8' - 0" A.F.F.
2' x 2' ACT System + 8' - 0" A.F.F.
2' x 4' ACT System + 8' - 0" A.F.F.
2' x 4' ACT System + 8' - 0" A.F.F.
2' x 4' ACT System + 8' - 0" A.F.F.
2' x 2' ACT System + 8' - 0" A.F.F.
2' x 4' ACT System + 8' - 0" A.F.F.
2' x 2' ACT System + 8' - 0" A.F.F.
2' x 4' ACT System + 8' - 0" A.F.F.
CEILING-MOUNTED EXAM
LIGHT, 42 WATTS, OFCI,
VIF LOCATION
2' x 2' ACT System + 8' - 0" A.F.F.
2' x 4' ACT System + 7' - 0" A.F.F.
G1
A3.0
EXISTING 2' X 2' CEILING GRID, LIGHT
FIXTURES, AND CONTROLS,
REPLACE THE ACOUSTIC PANELS
EXISTING EXPOSED
STRUCTURE, LIGHT
FIXTURES AND CONTROLS
RCP CEILING TYPE LEGEND:
2x4 ACP 2' x 4' ACP SQUARE LAY-IN
BASIS OF DESIGN:
ARMSTRONG ULTIMA
AIR ASSURE, FINISH WHITE
GRID
15/16", FINISHWHITE
2x2 ACP 2' x 2' ACP SQUARE LAY-IN
BASIS OF DESIGN:
ARMSTRONG ULTIMA
AIR ASSURE, FINISH WHITE
RCP LEGEND:
RCP NOTES:
1. ITEMS AND DEVICES TYPICALLY TO BE
CENTERED, ALIGNED, AND EQUALLY SPACED
IN ROOMS AND CORRIDORS UNLESS NOTED
OTHERWISE.
2. REFERENCE THE MEP DRAWINGS FOR MORE
DETAIL ABOUT FIXTURES AND DEVICES.
3. ALL EXPOSED MEP COMPONENTS, INCLUDING
CONDUIT, ELECTRICAL BOXES, JUNCTION
BOXES, DUCTWORK, HANGERS, LOUVERS,
DAMPERS, PLENUM BOXES, ETC. TO BE
PREFINISHED OR PAINTED.
4. ALL EXPOSED CONDUIT LOCATIONS TO BE
REVIEWED IN FIELD PRIOR TO FINAL
INSTALLATION BY ARCHITECT FOR APPROVAL.
5. PROVIDE UNISTRUT SUPPORTS FOR
SUSPENDED CEILING WHERE EXTENT OF
DUCTWORK PROHIBITS TYPICAL HANGER
INSTALLATION.
RECESSED DOWN LIGHT
RECESSED 2X4
RECESSED 2x2
SEE E2, ELECTRICAL LIGHTING PLAN FOR
SPECIFICATIONS
GWB: GYPSUM BOARD
5/8" MRGWB
BASIS OF DESIGN: USG
SHEETROCK ECOSMART
GYPSUM PANEL MOLD TOUGH
FIRECODE X
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1/8" = 1'-0"
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK
REFLECTED CEILING PLAN
A2.1
BID SET
1/8" = 1'-0"
REFLECTED CEILING PLAN
1st FLOOR
EL. 0' - 0"
G4
A4.1
G3
A4.2
CONCRETE-FACED
INSULATION PANELS, PAINT
DOWNSPOUT
EXISTING SCUPPER AND
DOWNSPOUT
ADDITIONEXISTING CONSTRUCTION
FLASHING AT GRADE
DASHED LINE
INDICATES FOOTING
APPROXIMATE GRADEDOWNSPOUT
EXISTING FENCE ATTACHED
TO BUILDING
EXISTING CMU, PAINT
WALL-MOUNTED 4FT HIGH
GALVANIZED CHAIN LINK FENCE
WITH ADDITIONAL 2FT HIGH CANTED
BARB WIRE TO MATCH EXISTING
MODIFY EXISTING FENCE TO TIE INTO NEW FENCE
SCUPPER
ROOFTOP UNIT
G1
A3.0
1st FLOOR
EL. 0' - 0"
ADDITION EXISTING CONSTRUCTION
140A
DASHED LINE
INDICATES FOOTING
DOWNSPOUT
CONCRETE-FACED INSULATION
PANELS, PAINT. SPACE PANELS EVENLY
ACROSS FACADE WITH MAXIMUM
COVERAGE AT CORNERS
APPROXIMATE GRADE
FLASHING AT GRADE
EXISTING GUTTER
INSTALL DOWNSPOUT
EXTEND EXISTING WALL
EXPANSION JOINT
CORNER MOUNTING PLATE
PLACE BOLTS THROUGH
MOUNTING PLATE AT LEAST 2"
CLEAR FROM A PANEL SEAM.
GENERAL NOTES:
1. REFER TO GENERAL NOTES ON SHEET A1.1
CONCRETE-FACED INSULATED PANELS
1. BASIS OF DESIGN: WALLGUARD BY T CLEAR CORPORATION
A. THICKNESS: 3" = R-15
EXTERIOR CONCRETE BLOCK
1. BASIS OF DESIGN: OMNI BLOCK
A. THICKNESS: 8" NOMINAL
B. R-VALUE: APPROXIMATELY R-20
FOUNDATON INSULATION
1. THICKNESS 3" = R-15
2. BASIS OF DESIGN: TYPE IX EPS
A. ACCEPTABLE SUBSTITUTE: FOAMULAR NGX XPS
DRAINAGE MAT
1. BASIS OF DESIGN: DELTA DRAIN 6200 HI-X BY DORKEN
WALL AIR/WEATHER BARRIER
1. SELF-ADHERED WATER RESISTIVE AIR BARRIER
2. BASIS OF DESIGN: BLUESKIN VP160
FOUNDATION AIR/WATERPROOF BARRIER
1. ROLLED, SELF-ADHERING WATERPROOF MEMBRANE
2. BASIS OF DESIGN: WR GRACE MEL-ROL
3. ACCESSORIES TO COMPLETE A FULLY WATERPROOF
INSTALLATION, INCLUDING CAPILLARY BREAK CONNECTING
WATERPROOFING TO UNDERSLAB VAPOR BARRIER.
BMC: BREATHABLE CMU MASONRY COATING
1. PAINT ALL EXTERIOR MASONRY AND CONCRETE FACED
WALLS WITH SILICATE COATING SYSTEM.
2. BASIS OF DESIGN:
a. PROSOCO ENVIRO KLEAN 2010 ALL SURFACE
CLEANER
b. PROSOCO BREATHABLE MASONRY COATING II
c. FOLLOW MANUFACTURER'S APPLICATION
INSTRUCTIONS
d. COLOR: MATCH ARCHITECT'S SAMPLE
UNDERSLAB VAPOR BARRIER
1. 6 MIL MINIMUM VAPOR BARRIER
2. BASIS OF DESIGN: STEGO WRAP
3. SEAL ALL SEAMS AND PENETRATIONS
INJECTION FOAM
1. BASIS OF DESIGN: INSULSMART INTERIOR FOAM INSULATION
BY CFI FOAM, INC.
FLASHING AND SHEET METAL
1. FLASHING AT GRADE
A. STAINLESS STEEL
2. SEE ROOF SPECS FOR GUTTER AND ROOF FLASHING
CHAIN LINK FENCE
1. ENGINEERED TO PROVIDE ROOF FALL PROTECTION
2. MOUNTED TO THE WALL WITH THREADED BOLTS EPOXIED
INTO THE CIPC EXTERIOR WALL.
3. PRODUCT: NON-PROPRIETARY
4. FINISH: GALVANIZED STEEL
5. AT PERIMETER, PROVIDE A 2FT HIGH CANTED BARB WIRE
EXTENSION AT THE TOP TO MATCH EXISTING.
CRUSHED STONE
1. CRUSHED STONE FOR USE AROUND DRAINS OR BELOW
FOUNDATIONS AND SLABS SHALL CONSIST OF SOUND,
TOUGH, DURABLE ROCK THAT IS GRADED WITHIN THE
FOLLOWING:
EXTERIOR SPECIFICATIONS
1st FLOOR
EL. 0' - 0"
EQEQ
1' - 1"
1' - 1"9' - 4"1' - 4"3' - 4"
4'
0"
CENTER CMU PATTERN IN
OPENING W/ 4" MIN CUT
BLOCKS
8'
8"
GLASS BLOCK
OMNI BLOCK, PAINT
M8-D
EXISTING STEEL
BEAM, PAINT
GLASS BLOCK CHANNEL
FRAME, PAINT
A5.0
G3
DUCTWORK CLEARS THE CHANNEL CROSS-
MEMBERS AND SWEEPS BACK BETWEEN
THE BEAMS TO THE SERVE THE EXISTING
BUILDING
RAISE EXISTING WATER PIPE
TO TUCK IT HIGHER
AGAINST THE ROOF DECK
FOR THE LENGTH OF THE
DISINFECTION CORRIDOR,
PROVIDE NEW INSULATION
WRAP.
PROVIDE 24" CURB WITH
BOTTOM SLOPE TO MATCH
STRUCTURE
A5.0
E5
SIM
A4.2
G3
DISHES
DISINFECTION
6'
8" 7'
6"
7'
0"
9'
1/
4"
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
As indicated
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK
EXTERIOR ELEVATIONS, BUILDING
SECTION, AND SPECIFICATIONS
A3.0
BID SET
1/4" = 1'-0" C5
WEST REAR ADDITION ELEVATION
1/4" = 1'-0" E5
SOUTH REAR ADDITION ELEVATION
SIEVE SIZE PERCENT FINER BY WEIGHT
5/8 INCH 100
1/2 INCH 85-100
3/8 INCH 15-45
NO. 4 0-15
NO. 8 0-5
1/4" = 1'-0" G5
COURTYARD INFILL ELEVATION
2 ADDENDUM #4 6/23/26
1/2" = 1'-0" G1
ADDITION CROSS SECTION
3'
M
IN
G R
A D
E T
O B
O
TT
O M
O F
FO
O
TI
N
G
G R
A D
E L
E V
E L
V A
R
IE
S
1/4" / 12"
4" M
IN
EXISTING WALL OPENING
FOR SCUPPER
GRAY SHADING
INDICATES EXISTING
CONSTRUCTION
EXTERIOR WALL CONSTRUCTION
CONCRETE FACED INSULATED WALL PANEL (R-15)
AIR/ WEATHER BARRIER
8" CIPC RETAINING WALL
EXTERIOR FOUNDATION CONSTRUCTION
DRAINAGE PANEL
3" RIGID INSULATION (R-15)
AIR/ WATERPROOF BARRIER
CIPC RETAINING WALL
TYPIVALROOF CONSTRUCTION
SINGLE-PLY MEMBRANE ROOF
1/2" COVER BOARD (R-2.5)
ROOF INSULATION - 2 LAYERS
(2.5 IN, R-28.8 TOTAL)
VAPOR RETARDER
METAL DECK
2x10 WOOD JOISTS @ 1'-0" O.C.
SLOPE STRUCTURE 1/4" /1'-0"
15' - 0"
9'
4"
V
IF
7'
0"
D
IS
H E
S R
O O
M
7'
6" T
O B
O
TT
O M
O F
C E
IL
IN
G
A5.0
G4
A5.0
G7
1/4" / 12"
HUC26 SIMPSON STRONG-TIE CONCEALED JOIST HANGER W/
4 - 1/4" X 2 1/4" TITEN TUBRO SCREWS INTO GF CMU
4 - 1/4" X 1 3/4" INTO CONCRETE
4 - 0.148D X 1 1/2" WOOD SCREWS INTO JOIST
2X10 DFL NO. 2 OR BETTER AT 12" O.C.
RETAINING WALL CONSTRUCTION
(f'c) MIN 4000 PSI
EXPOSURE CATEGORY F
#6 BARS VERTICALLY @ 9" O.C.
#5 BARS HORIZONTALLY @ 12" O.C.
RETAINING FOOTING CONSTRUCTION
3'-0" HEEL, 2'-0" TOE, TOTAL WIDTH 5'-8"
ON CRUSHED STONE
STONE SHOULD EXTEND 1'-0" BEYOND EDGES OF FOOTING
3" CLEAR COVER FOR ALL REINFORCEMENT
4EA - #5 LONGITUDINALLY @ 12" O.C.
#5 TRANSVERSELY @ 18" O.C., OFFSET FROM #6 LEG
SLAB CONSTRUCTION
6" SLAB
VAPOR BARRIER
6" LAYER CRUSHED STONE
(f'c) MIN 4500
EXPOSURE CATEGORY S
SAW CUT PANEL RATIO NOT TO EXCEED 2.5:1
TEAR AWAY FELT AND
CAULK SLAB PERIMETER
DRILL TEST HOLE TO CONFIRM
GFCMU OR BOND BEAM AT JOIST
HANGERS. IF CMU IS EMPTY SUPPORT
NO MORE THAN 3'-0" AT A TIME AND
REMOVE BLOCKS TO ADD BACKER
AND FILL CELLS WITH TYPE N GROUT
AT JOIST HANGERS.
6"
PERFORATED
PIPE
6"
PERFORATED
PIPE
PERMEABLE
FABRIC SOCK
CRUSHED STONE
WRAP CRUSHED STONE
IN GEOTEXTILE FABRIC
CRUSHED STONE
GEOTEXTILE FABRIC
WRAPS CRUSHED STONE
THRU - CLADDING METAL FLASHING
AT GRADE, HEM THE BOTTOM
4"
WRAP AIR/WEATHER
BARRIER OVER FLASHING
CAPILLARY BREAK AT FOOTING,
CONTINUOUSLY CONNECT
FOUNDATION WATERPROOFING
WITH UNDERSLAB VAPOR BARRIER
AND PROTECT FOUNDATION WALL
TURN UP VAPOR
BARRIER AND TAPE
TO FOUNDATION
7'
6"
1'
3/
8"
CONNECT DOWNSPOUTS TO
PERIMETER DRAIN
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 1/2" = 1'-0"
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK/ ZS
WALL SECTIONS
A4.1
BID SET
1 1/2" = 1'-0"
ADDITION SECTION 1
CUT EXISTING
GUTTER BACK
ADD DOWNSPOUT
GRAY HATCH
INDICATED EXISTING
CONSTRUCTION, VIF
TEAR AWAY FELT
AND CAULK AT SLAB
PERIMETER, TYP
WRAP VAPOR BARRIER UP
AND TAPE TO EXISTING
FOUNDATION
EXISTING
PARAPET
BEYOND
ADD TWO COURSES OF CMU
ON TOP OF EXISTING WALL,
AND INSTALL PARAPET
FLASHING
FOOTING TO BE 18" BELOW BOTTOM OF SLAB, 2' WIDE
(2) #5 BARS CONTINUOUS, (1) #5 BAR CIP WITH 18" EXTENSION INTO
WALL AND 90 DEGREE BEND 12" EXTENSION INTO FOOTING @ 16" O-C
F'C 3000 PSI
GRADE 60 REINFORCEMENT (TYP)
VAPOR BARRIER UNDER
SLAB, CONNECT WITH
CAPILLARY BREAK AT
FOOTING
FIRE-RATED BLOCKING
2X PT SILL PLT W/ 1/2" DIA
HEX HEAD ANCHOR BOLTS
SPACED 4' O-C EMBED MIN.
6" IN BOND BEAM.
TYPICAL ROOF
CONSTRUCTION
INSULATE EXISTING
CMU WALL WITH
INJECTION FOAM
APPLY BREATHABLE
MASONRY COATING TO
THE EXTERIOR OF THIS
WALL TO PREVENT WATER
INFILTRATION
A5.0
E5
GROUT SOLID BOND BEAM
TOP COURSE W/ (4) #4
BARS IN TWO LAYERS
SUBMIT GROUT MIX FOR
APPROVAL
#4 BAR VERTICAL AT 16" O-C
LADDER REINFORCEMENT AT
16" O.C. VERTICALLY
SECURE JOISTS TO WALL
WITH TWIST STRAP TIES,
SUBMIT STRAP FOR
APPROVAL. BLOCK
BETWEEN ALL JOISTS AT
WALL.
TYPICAL EXTERIOR WALL CONSTRUCTION
SEE TYPICAL EXTERIOR NOTES
ON DETAIL /G4 A4.1
CHAIN LINK POST
A5.0
E5
SIM
WRAP AIR/WEATHER BARRIER OVER
PARAPET AND TIE INTO VAPOR BARRIER
DOWEL NEW CMU INTO
EXISTING CMU WALL
ADDITION PARAPET WALL CONSTRUCTION
SEE TYPICAL EXTERIOR WALL CONSTRUCTION
VAPOR BARRIER
2 1/2" ROOF INSULATION
SINGLE-PLY MEMBRANE ROOF
1 1/2" = 1'-0" G3
ADDITION SECTION 2
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
1 1/2" = 1'-0"
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK/ ZS
WALL SECTIONS
A4.2
BID SET
MANUFACTURER
RECOMMENDED PARAPET
CURB FLASHING
PARAPET SHEET METAL
COPING
EXTEND MEMRANE OVER PARAPET
FOR COMPLETE COVERAGE OF THE
TOP OF WALL AS RECOMMENDED
BY MANUFACTURER
PRESSURE-TREATED BLOCKING
EXTEND MEMBRANE TO
COVER THE JOIN OF THE
BLOCKING AND MASONRY
EXTEND VAPOR BARRIER
OVER TOP TO PROVIDE A
CAPILLARY BREAK BETWEEN
MASONRY AND PRESSURE
TREATED BLOCKING
6" CONDUCTOR HEAD
WITH CONCEALED
HANGERS
FORMED METAL SCUPPER FLASHING
ROOF MEMBRANE STRIP OVER
SCUPPER FLASHING AS
RECOMMENDED BY THE
MANUFACTURER
WRAP VAPOR BARRIER ONTO FACE
OF WALL PER MANUFACTURER'S
RECOMMENDATIONS
WRAP AIR/WEATHER BARRIER OVER
BLOCKING FOR CONTINUOUS
COVERAGE
WRAP ROOF MEMBRANE ONTO
AIR/WEATHER MEMBRANE ON VERTICAL
FACE OF BLOCKING
TYPICAL ROOF
CONSTRUCTION
TYPICAL EXTERIOR WALL CONSTRUCTION
1/4" / 12"
D7
A5.0
SEALANT
STRIP INTO THE EXISTING ROOF
MEMBRANE PER MANUFACTURER'S
RECOMMENDATIONS
PARAPET/ CURB WALL
TRANSITION PER
MANUFACTURER'S
RECOMMENDATIONS
4" M
IN
REMOVE EXISTING PARAPET FLASHING
BEYOND AT ADDITION INTERSECTION
AND RE-INSTALL MEMBRANE FLASHING
AND METAL PARAPET COPING, PER
TYPICAL PARAPET FLASHING DETAIL
D7
A5.0
SIM
ADDITION PARAPET
WALL CONSTRUCTION
FORMED SCUPPER
METAL FLASHING
ROOF MEMBRANE STRIP OVER
SCUPPER FLASHING AS
RECOMMENDED BY THE
MANUFACTURER
PRESSURE TREATED BLOCKING
WRAP VAPOR BARRIER INTO
SCUPPER OPENING
WRAP AIR/WEATHER BARRIER INTO SCUPPER
OPENING AND OVERLAP VAPOR BARRIER
CONDUCTOR HEAD BELOW 3"
G7
A5.0
SEALANT, TYP
8" M
IN
IM
U M
3"
SLOPE BOTTOM OF
CURB TO MATCH
STRUCTURAL SLOPE
FOLLOW MANUFACTURER'S
RECOMMENDING CURB
FLASHING DETAILS
WRAP MEMBRANE
OVER CURB
COUNTERFLASHING
PREFORMED INSULATED CURB
8" M
IN
" M
IN
USE MANUFACTURER
RECOMMENDED PIPE
FLASHING
SEALANT, TYP
C
IT
Y O
F N
E W
H A
VE
N
D E
P A
R
TM
E N
T O
F E
N G
IN
E
E R
IN
G
TH
E
H O
N O
R A
B
LE
J U
S
TI
N M
. E
LI
C K
E R
, M A
Y O
R
G
IO
V A
N N
I Z
IN
N , P
.E
C
IT
Y E
N G
IN
E
E R
PROJECT NAME AND ADDRESS
DRAWN BY DESIGNED BY
DATE
PROJECT NUMBER
PROFESSIONAL SEAL
SHEET TITLE
SHEET NUMBER
PROJECT PHASE
NO. DESCRIPTION DATE
SCALE
1 2 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
As indicated
C
U s e rs \m k o p s \D o c u m e n ts
\2
-1
-2 A n im a l S h e lt e r R
M
K o p s .r vt
4/10/2026
21-120-25
ANIMAL SHELTER
81 FOURNIER STREET
NEW HAVEN, CT 06511
MAK MAK
ROOF AND SIDEWALK DETAILS
A5.0
BID SET
3" = 1'-0"
E5
TYPICAL PARAPET DETAIL
3" = 1'-0" G7
SCUPPER DETAIL
3" = 1'-0"
G4
ROOF TRANSITION AT EXISTING SCUPPER
D1
SIDEWALK DETAILS
3" = 1'-0" D7
SCUPPER PLAN DETAIL
3" = 1'-0" G3
CURB DETAIL
3" = 1'-0"
ROOF PIPE PENETRATION
F
VETERINARY
DISHES
STORAGE
GROOMING
GROOMING
TABLE, NIC
EXAM TABLE WITH
INTERNAL SCALE. NIC
A6.1 A6.1
A6.1 E9
16' - 2 5/8" 0' - 4 7/8" 8' - 2 3/8" 0' - 7 1/4" 11' - 2 7/8" 4' - 7 5/8"
GROOMING
BATH TUB,
SALVAGED
SHELVING, TYP, NIC
G4
A4.1
G3
A4.2
24"38"132" 40" 40" 40" 124"
NEW DOOR IN EXISTING
WALL, ALIGN OPENING
WITH MASONRY
COURSING AS POSSIBLE
4"
P6
P4A
M8-A
M8-B
M8-D
M8-C
140C
140A
E7 E4
A3.0
G5
13" 40" 16"
G1
A3.0
DISINFECTION
140A
VESTIBULE
HALL
UPPER
36"W x 18"H x 12"D
UPPER
15"W x 30"H x 12"D
UPPER
15"W x 30"H x 12"D
SINK BASE
36"W x 24"D
BASE
15"W x 24"D
BASE
15"W x 24"D
GROOMING
BATH,
SALVAGED
EXISTING
RECEPTACLE,
REPLACE DEVICE
WIREMOLD ON
MASONRY
TA.06 TA.08
A6.1
E2
BREAK ROOM
MECH
110B
HALL
ADA LAV
60" MIN CLEAR
3"
PATCH WALL WHERE DOOR FRAME WAS REMOVED
1' - 6"
4"
1'-6" MIN
1' - 8"
1'
6"
ALIGN FACE OF
WALL WITH
MASONRY
OPENING P4F
P4B
CLEAR SPACE TO
USE VERTICAL
BABY CHANGER
ADA TURNING
RADIUS
PULL SIDE ADA DOOR CLEARANCE
PUSH SIDE ADA
DOOR CLEARANCE
TA.06
TA.07
PL.02
TA.02 TA.05
TA.04
TA.03
TA.01
" M
IN
C
LE
A
R
DOUBLE-TIER LOCKERS, QTY (4)
C
LE
A R
M
IN
ADA
APRON
UPPER
21"W x 30"H x 12"D
UPPER
36"W x 18"H x 12"D UPPER
21"W x 30"H x 12"D
21"W x 24"D
ADA BASE
21"W x 24"D
ADA BASE
REFRIGERATOR,
OFCI
WIREMOLD, TYP ON
MASONRY WALLS,
NOT ACROSS SINK
TA.06 TA.08
ACCESSIBLE
LAVATORY
MIRROR
FINISH FLOOR
TOILET PAPER
HOLDER
SANITARY
NAPKIN
DISPOSAL
NOTES:
1. ALL DEVICES SHALL BE
INSTALLED AT MOUNTING
HEIGHTS AS INDICATED
ON THE DETAIL UNLESS
OTHERWISE NOTED.
2. PROVIDE ALL NECESSARY
BLOCKING
TYPICAL MOUNTING
HEIGHTS
PL.02 TA.01 TA.03 TA.04
CALL FOR
ASSISTANCE ALARM
PULL SWITCH
TA.05
3'
3"
" M
A X
PAPER TOWEL
DISPENSER
TA.06 TA.07
BABY
CHANGING
TABLE
DISINFECTION
SINK
PL.06
24"
2'
2'
1"
A T
C A
S E
W O
R K
TA.08
TA.10
TA.03
TA.02
TA.02
42"12"
6"
39"
ELEVATION AT ADA TOILETPLAN AT ADA TOILET
TOILET TISSUE DISPENSER
CALL FOR ASSISTANCE ALARM
PULL SWITCH REQUIRED IN
SINGLE…