Hess.pdf

PDF 2 MB Posted

Attached to
HM - Noontime Demolition Project Federal contract opportunity
Solicitation number
AG-569R-S-14-0040
Issued by
Department of Agriculture Forest Service R9-Eastern Region

About this file

Attachment 7 - Hess Site

View the file

Other files for this federal contract opportunity

Other files attached to HM - Noontime Demolition Project, newest first.
File Type Posted
Fountain.pdf PDF
Noontime_Maps.pdf PDF
Cline_Property.pdf PDF
AG-569R-S-14-0040.rtf RTF text file
Allen.pdf PDF
Oakey_Report_doc.pdf PDF
Experience_Questionnaire.doc DOC document
Ahlborn.pdf PDF
05-2271.txt TXT text file
Noontime_Pictures.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS

COMPLIANCE SURVEY

EPA, OSHA and MIOSHA Guidance

FOR ASBESTOS-CONTAINING MATERIALS

ADDITIONAL TESTING FOR LEAD-BASED PAINT

Abandoned Residential Property

Cabin 17

Mio, Michigan

PREPARED PREPARED PREPARED PREPARED FOR: FOR: FOR: FOR:

HuronHuronHuronHuron----Manistee National ForestManistee National ForestManistee National ForestManistee National Forest

1755 South Mitchell St1755 South Mitchell St1755 South Mitchell St1755 South Mitchell St

Cadillac, MI 49601Cadillac, MI 49601Cadillac, MI 49601Cadillac, MI 49601----1143114311431143

PREPARED BY: PREPARED BY: PREPARED BY: PREPARED BY:

CompliCompliCompliCompli----ChekChekChekChek

2709 Geert Court2709 Geert Court2709 Geert Court2709 Geert Court

Lansing, MI 48910Lansing, MI 48910Lansing, MI 48910Lansing, MI 48910

06-04-13

Burt R. Russell Michigan Inspector # AA5519

Table of Contents

Report Section

Project Summary

1A: .........................................................................................................Project Scope 1B: ............................................................................................. Summary of Findings 1C:.....................................................................................Abatement Cost Estimates

Results and Regulatory Guidelines

2A-1:............................................ Regulated Asbestos-Containing Materials (RACM) 2A-2:............NESHAPs Category 1 & 2 That Must Be Removed Before Demo/Reno 2A-3:.........................NESHAPs Category 1 & 2 That May Remain for Demo/Remno 2A-4:....................................................................Non-Asbestos-Containing Materials 2B : .......................................................Material Identification and Sample Locations 2C :................................................................................................ Analytical Results 2D :..............................................................................................Schematic Diagram 2E : ............................................................... OSHA/MIOSHA Compliance Guidance

Asbestos Sampling and Analytical Procedures

Lead Paint Testing (XRF Method

Inspector and Laboratory Certification

PROJECT SCOPE AND SUMMARY OF FINDINGS

SECTION 1

On 05-25-13, Compli√Chek, LLC (C√C) conducted an EPA-OSHA Compliance Survey for asbestos-containing materials (ACM) at Cabin 17, Mio, Michigan. The building was observed to be in poor condition and is a planned demolition and sit clearance.

1A Project Scope: Asbestos

The inspector performed a space-by space survey of materials and their locations, employing destructive methods in order to locate and sample concealed materials. Compli√Chek uses assessment, sampling and analytical procedures standardized in 1987 by the EPA Asbestos Hazards Emergency Response Act, (40 CFR 763 Subpart M;

AHERA). The Michigan–licensed inspector on this project was Burt Russell. Requirements for performing a survey in residential properties with under 4 dwelling units prior to renovation or demolition are found in MIOSHA Asbestos Standards for Construction, Part 602. Requirements for performing a pre-demolition or pre-renovation survey in most other structures are found in Federal Standard Number 40 CFR 61, entitled: National Emissions Standards for Hazardous Air Pollutants (NESHAP). For the purpose if this survey, Compli√Chek will use the standardized terminology adopted by the NESHAP and designate all materials as one of the following:

• RACM (Regulated Asbestos-Containing Materials) are any of the following:

� Friable ACM � NCAT-1 ACM that has become friable or will be subject to sanding, grinding, cutting or abrading � NCAT-2 ACM that is likely to or has become crumbled, pulverized or reduced to powder by renovation or demolition activities.

RACM is detailed and discussed in Section 2A-1.

RACM must always be removed from the structure before demolition or, if it will be disturbed, before renovation.

• NCAT-1 (NESHAP CATegory- 1 non-friable material) � gaskets, packings, flooring, asphalt roofing products containing more than 1% asbestos).

NCAT-1 is detailed and discussed in Sections 2A-2& 2A-3.

Some NCAT-1 materials may remain in the structure during a demolition if they are not friable prior to the demolition. NCAT-2 (NESHAP CATegory- 2 non-friable material) � Any ACM, excluding Category 1, containing more than 1% asbestos that, when dry, cannot be crumbled, pulverized or reduced to powder by hand pressure.

NCAT-2 is detailed and discussed in Sections 2A-2& 2A-3 Some NCAT-2 materials may remain in the structure during a demolition. See Sections 2A-2& 2A-3 for further guidance.

• NACM (Nonasbestos-Containing Material) are materials containing less than 1% asbestos.

� All NACM discovered is detailed in Section 2A-4 of this report.

1B Summary of Findings

RACM was discovered: See Section 2A for RACMs & their locations.

Combined RACM quantities:

220 square feet: Felt backer on rolled flooring

These amounts meet or exceed the NESHAP Threshold (260 Lin Ft or 160 Sq Ft). The NESHAP rules may not apply to this residential structure under 4 dwelling units, however, due to Federal ownership and intended re-purposing of the property it is not clearly excluded from the rules and the inspector recommends full adherence to the NESHAP. Additional guidance for OSHA / MIOSHA worker protection rules still apply and is provided in Section 2E. and while NESHAP rules may not apply apply to your project. Section 2B of this report provides recommendations for compliance with NESHAPs requirements (defined below) and additional guidance for OSHA / MIOSHA worker protection is provided in Section 2E.

NCAT-1 was not discovered

NCAT-2 was not discovered

1C Abatement Cost Estimates

220 square feet of felt-backed rolled flooring on concrete substrate:

Mobilization: $400 - $600 Removal flooring and backer: $300 - $450

RESULTS AND REGULATORY GUIDELINES: SECTION 2

A material is considered by the Environmental Protection Agency (EPA) and the State of Michigan, Department of Labor and Economic Growth to be an asbestos-containing material (ACM) if at least one analysis from a collected sample yields a result greater than 1% asbestos (chrysotile, amosite, tremolite, crocidolite), or, if a material is assumed to contain asbestos based on the knowledge and observation of the licensed inspector. For all RACM, NCAT-1 and NCAT-2 ACM identified during the survey, the following regulatory requirements are applicable.

2A-1

Regulated Asbestos-Containing Materials (RACM)

The felt backer on flooring in the bathroom, living room, hall and bedroom would be rendered friable during demolition and must be removed prior to demolition.

SPACE NUMBER/SPACE DESCRIPTION: ASSIGNED BY THE INSPECTOR, IDENTIFIES SPACES OR AREAS OF BUILDING INTERIORS/EXTERIORS; MATERIAL NUMBER / MATERIAL DESCRIPTION: ASSIGNED BY INSPECTOR FOR EACH MATERIAL IDENTIFIED; MATERIAL TYPE: (SM) SURFACING MATERIAL / (TSI) THERMAL SYSTEM

INSULATION / (MM) MISCELLANEOUS MATERIAL NESHAP CATEGORY: NCAT-1 = CATEGORY 1 NON-FRIABLE / NCAT-2 = CATEGORY 2 NONFRIABLE / RACM= REGULATED ASBESTOS-CONTAINING MATERIAL / NA = NON-ASBESTOS CONTAINING MATERIAL PERCENT ASBESTOS: PERCENT BY WEIGHT OR ND (NONE

DETECTED) F/NF: FRIABLE OR NON-FRIABLE; MATERIAL IS ABLE TO BE REDUCED TO POWDER BY HAND PRESSURE; QUANTITY: ESTIMATED AMOUNT OF MATERIAL

UNIT OF MEASURE: (LF)/LINEAL FEET; (SF)/SQUARE FEET; (EA)/EACH

S P

A C

E

N U

M B

R

SPACE DESCRIPTION

M A

T E

R

IA

L

M B

MATERIAL DESCRIPTION

A

T E

R

T Y

P

A

T E

R

O

N D

IT

IO

S H

T

E G

O

R C

E

S

B E

S T

F /N

Q

A N

T

IT

IT

A S

U

2A.1 Regulated Asbestos-Containing Materials (RACM) 2A.1

1 KITCHEN & LIVING ROOM 11 ROLLED FLOORING M FAIR RACM 10% F 140 SF

2 BATHROOM 15 ROLLED FLOORING (TOILET) M FAIR RACM 20% F 12 SF

3 HALL 11 ROLLED FLOORING M FAIR RACM 10% F 8 SF

4 BEDROOM 11 ROLLED FLOORING M FAIR RACM 10% F 60 SF

Note: The MIOSHA standard does not use the term “RACM” and the NESHAP rules do not correlate directly with OSHA. This part of the report attempts to address both standards at the point where air quality issues and worker protection intersect. See Section 2E for additional MIOSHA guidance.

<260 Linear/160 square ft = NESHAP rules may not apply; Assume compliance is required.

>260 Linear/160 square ft = NESHAP rules apply;

Residential structure under 4 units: NESHAP rules do not apply: Assume compliance is required.

Residential structure being demolished for development and not privately owned: NESHAP rules apply Non-friable removal or demo: NESHAP rules do not apply; Assume compliance is required.

>10 lin/15 sq ft. (MIOSHA) MDLEG Notification required at least 10 calendar days prior to startup.

• Work area containment (EPA/MIOSHA)

• Post-abatement air clearance performed when negative pressure enclosure is used (MIOSHA).

• Adequately wet the material during removal (EPA/MIOSHA)

• At least one 40-hour trained Competent Person must be present during RACM removal. (MIOSHA)

• Trained and licensed personnel must remove RACM prior to demolition. (MIOSHA)

2A.2 NESHAPs Category 1 & 2 That Must Be Removed Before Demo/Reno (NONE DISCOVERED) 2A.2

2A.3 NESHAPs Category 1 & 2 That May Remain for Demo/Remno (NONE DISCOVERED) 2A.3

2A-4 Non-Asbestos-Containing Materials

All materials yielding analytical results of less than 1% asbestos (negatives) is organized here.

SPACE NUMBER/SPACE DESCRIPTION: ASSIGNED BY THE INSPECTOR, IDENTIFIES SPACES OR AREAS OF BUILDING INTERIORS/EXTERIORS; MATERIAL NUMBER /

MATERIAL DESCRIPTION: ASSIGNED BY INSPECTOR FOR EACH MATERIAL IDENTIFIED; MATERIAL TYPE: (SM) SURFACING MATERIAL / (TSI) THERMAL SYSTEM INSULATION / (MM) MISCELLANEOUS MATERIAL NESHAP CATEGORY: NCAT-1 = CATEGORY 1 NON-FRIABLE / NCAT-2 = CATEGORY 2 NONFRIABLE / RACM= REGULATED

ASBESTOS-CONTAINING MATERIAL / NA = NON-ASBESTOS CONTAINING MATERIAL PERCENT ASBESTOS: PERCENT BY WEIGHT OR ND (NONE DETECTED) F/NF: FRIABLE OR NON-FRIABLE; MATERIAL IS ABLE TO BE REDUCED TO POWDER BY HAND PRESSURE; QUANTITY: ESTIMATED AMOUNT OF MATERIAL UNIT OF MEASURE: (LF)/LINEAL

FEET; (SF)/SQUARE FEET; (EA)/EACH

S P

A

M B

SPACE DESCRIPTION

A

T E

R

M B

MATERIAL DESCRIPTION

A T

E R

T E

R

N D

IT

IO

S H

T

E G

O

R C

E

B E

S T

/N

Q

A N

T

IT

IT

A S

U

2A.4 NACM: Non-Asbestos-Containing Materials (Testing <1%) 2A.4

EX-1 HOUSE EXTERIOR 12 ASPHALT FLASHING PAPER M FAIR NA ND F <200 SF

EX-1 HOUSE EXTERIOR 13 TOP HOUSE SHINGLE M FAIR NA ND NF 360 SF

EX-1 HOUSE EXTERIOR 14 BOTTOM HOUSE SHINGLE M FAIR NA ND NF 360 SF

1 KITCHEN & LIVING ROOM 10 WOOD FIBER CEILING M FAIR NA ND F 140 SF

2 BATHROOM 10 WOOD FIBER CEILING M FAIR NA ND F 12 SF

3 HALL 10 WOOD FIBER CEILING M FAIR NA ND F 8 SF

4 BEDROOM 10 WOOD FIBER CEILING M FAIR NA ND F 60 SF

2B Material Identification and Sample Location

All sample sites and information about asbestos content is organized here.

Material #: 10 WOOD FIBER CEILING

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

10 A LIVING ROOM NONE DETECTED NA

10 B BEDROOM NONE DETECTED NA

Material #: 11 ROLLED FLOORING

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

11 A HALL 10.0% CHRYSOTILE

11 B LIVING ROOM NOT ANALYZED NA

Material #: 12 ASPHALT FLASHING PAPER

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

12 A EXTERIOR WALL NONE DETECTED NA

12 B DEBRIS ON PATIO NONE DETECTED NA

Material #: 13 TOP HOUSE SHINGLE

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

13 A SOUTHEAST ROOF CORNER NONE DETECTED NA

Material #: 14 BOTTOM HOUSE SHINGLE

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

14 A SOUTHEAST ROOF CORNER NONE DETECTED NA

Material #: 15 ROLLED FLOORING BATHROOM

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

15 A BATHROOM 20.0% CHRYSOTILE

2C

Laboratory Analyses

Analyses by Polarized Light Microscopy, Point Count Method or Transmission Electron Microscopy are organized here.4

Note: TESC Sample numbers 18 through 25 were collected from Cabin 17.

�� !"#$%&'#()*+,%-.#/)%,0##1*2'3#(0##42,5)'62%+0#78#9���9 ###########################################################################################:;<=>?@=A>BACDCEFGHC:;<=>?@=A>B?C

##(IJK#81($1LM1#184NJ$#8O8JP1Q1#1I448/P##

RSTU

���V��W�

XYUZT

! 9 ��[�090�

\]��������V��� ̂��������V

Z_T̀_Ta b̀_TbRTZ_ b̀_TbRTZ_ b̀_TbRTZ_ c� a���Wa�d ����e fe g��� �c �����̂�e g��� �c ����h���e g��� �c ��̂���e

����h��e

L$1i 184NJ$#j iJQ$OL#184NJ$#Qk l#m/M11#k$1i/QNLQMO

$1LQ48L$k n#81($1LM1

OMO#81($1LM1

n#oQ($/1

OMO#oQ(/MI1 n#48L$/Q8J1

������e a�db fe

RTp ����]��V� YTpZ� b h����q W��r s�t��V O8kZ

����]��V� YTpZd b h����q s�t��V O8kR

UYp ����]��V� RpR� b ���r s�t��V O8k_

����]��V� RpRd b s�t��V O8kX

����]��V� Rp_� b d��q� s�t��V O8k`

����]��V� Rp_d b d��q� s�t��V O8ku

USpX� b ���r �v��V� � �n#i6-.&)'253S

Xd

N)&2'2w3#1')xY

����]��V� YTp�̀ b d��y ������ � O8kU

����]��V� YTpd̀ b d��y ������ � O8kZT

��]�Vv�r� ��r _T�

RTZ_ �̂W�

Z �s z{|}~���{���{�{~��������{�����{����������������|���������������������|��{����������������������~������~{�����z{|}~���������������� ¡��¡������¢�£¤ ¡ ��v ¥�����v s�� g������������ �s �Vt�V��V d]� d]��v��W ��������V¥� uTTb��U_bZZu� a]�r

ZUU_�

g���y��ve v���y��v ��b�� t���q v���y��v �s �����v ¦��������W �����e Zp �Vt�V��V§�

���VV

s�t�� �V ����r̈�v s�� ©]����r y������ t��� � ��y�����vV tr y�]��

����V��VV���

���y���� ��y��Vy��r s�� ��������V ��W]����v tr

���VV���

����v��vV s�� \�̈��v�]V ̂���]����V§ ��v s�]�v y������

��VV

���y��� ¦ªZTp§ �Vt�V��V tr ̂�����̈�v ��W�� ��y��Vy��r d��� V�� �y�V ����t�� s�� �vv������� s��� ���V V���� t� �����v]y�v� �«y��� s]�� q������ �s �����W�� �y� ��y� ���V �]V� t� ]V�v tr y]V����� y���� ���v]y� y����s�y������ ��v��V����� tr ��r �W��yr �s c�v���� ���V ��V� ������V ���r ����¦V§ ��V��v�

��t ��v�e

RTTSUX�T

J$m$Ok ��g¬�� �Vt�V��V g���y��v� a�¬a���� �����]�v

/3w23̄3,#(.#8*'6)-2°3,#12±+%')-.²###

³́µ¶·̧¹ºµ¶»·¼½·½́µ¹¾¿·À́¾Á¾¶¹Âû·ÄºÅ¾¿ºÃ¾¿Æ·Ç¹¿́Èþ¿ ÉẾ˾µ¶·³ºµ¶»·½́µ¹¾¿·À́¾Á¾¶¹Â÷············································

�� !"#$%&'#()*+,%-.#/)%,0##1*2'3#(0##42,5)'62%+0#78#9���9 ###########################################################################################:;<=>?@=A>BACDCEFGHC:;<=>?@=A>B?C

##(IJK#81($1LM1#184NJ$#8O8JP1Q1#1I448/P##

RSTU

���V��W�

XYUZT

! 9 ��[�090�

\]��������V��� ̂��������V

Z_T̀_Ta b̀_TbRTZ_ b̀_TbRTZ_ b̀_TbRTZ_ c� a���Wa�d ����e fe g��� �c �����̂�e g��� �c ����h���e g��� �c ��̂���e

����h��e

L$1i 184NJ$#j iJQ$OL#184NJ$#Qk l#m/M11#k$1i/QNLQMO

$1LQ48L$k n#81($1LM1

OMO#81($1LM1

n#oQ($/1

OMO#oQ(/MI1 n#48L$/Q8J1

������e

ZTTpq�

��st�� O8kZZ

ZTTpqd

��st�� O8kZR

USpS� d��s�

��r� �n#i6-.&)'253Z_

Sd

N)&2'2u3#1')vZX

URpY� d��w �t��V� � xn#i6-.&)'253Z̀

Yd

N)&2'2u3#1')vZq

����]��V� YTpU� b d��w ������ � O8kZS

����]��V� RpZT� b h����s y�z��V O8kZY

ZTp c�z��W��VV YTpZZ� b ��t y�z��V �!n#i6-.&)'253ZU

ZZd

N)&2'2u3#1')vRT

��]�Vt�r� ��r _T�

RTZ_ �̂W�

R �y

��t ¦�����t y�� g������������ �y �Vz�V��V d]� d]��t��W ��������V¦� qTTb��U_bZZq� a]�r

ZUU_�

g���w��te t���w��t ��b�� z���s t���w��t �y �����t §��������W �����e Zp �Vz�V��V̈�

���VV

y�z�� �V ����r©�t y�� ª]����r w������ z��� � ��w�����tV zr w�]��

����V��VV���

���w���� ��w��Vw��r y�� ��������V ��W]����t zr

���VV���

����t��tV y�� \�©��t�]V ̂���]����V̈ ��t y�]�t w������

��VV

���w��� §«ZTp ̈�Vz�V��V zr ̂�����©�t ��W�� ��w��Vw��r d��� V�� �w�V ����z�� y�� �tt������� y��� ���V V���� z� �����t]w�t� �¬w��� y]�� s������ �y �����W�� �w� ��w� ���V �]V� z� ]V�t zr w]V����� w���� ���t]w� w����y�w������ ��t��V����� zr ��r �W��wr �y c�t���� ���V ��V� ������V ���r ����§V̈ ��V��t�

��z ��t�e

J$m$Ok ��g�� �Vz�V��V g���w��t� a�a���� �����]�t®

/3u23°3,#(.#8*'6)-2±3,#12²+%')-.³### µ́¶·̧¹º»¶·¼̧½¾̧¾µ¶º¿À̧Áµ¿Â¿·ºÃļ̧ŻƿÀ»Ä¿ÀÇ̧ȺÀµÉÄ¿À Ê˵̿¶·̧́ »¶·¼̧¾µ¶º¿À̧Áµ¿Â¿·ºÃÄ̧̧̧¸̧̧̧¸̧̧̧¸̧̧̧¸̧̧̧¸̧̧̧¸̧̧̧¸̧̧̧¸̧̧̧¸̧̧̧¸̧̧̧¸̧

�� !"#$%&'#()*+,%-.#/)%,0##1*2'3#(0##42,5)'62%+0#78#9���9 ###########################################################################################:;<=>?@=A>BACDCEFGHC:;<=>?@=A>B?C

##(IJK#81($1LM1#184NJ$#8O8JP1Q1#1I448/P##

RSTU

���V��W�

XYUZT

! 9 ��[�090�

\]��������V��� ̂��������V

Z_T̀_Ta b̀_TbRTZ_ b̀_TbRTZ_ b̀_TbRTZ_ c� a���Wa�d ����e fe g��� �c �����̂�e g��� �c ����h���e g��� �c ��̂���e

����h��e

L$1i 184NJ$#j iJQ$OL#184NJ$#Qk l#m/M11#k$1i/QNLQMO

$1LQ48L$k n#81($1LM1

OMO#81($1LM1

n#oQ($/1

OMO#oQ(/MI1 n#48L$/Q8J1

������e

����]��V� RpZR� b d��q r�s��V O8kRZ

����]��V� RpZRd b d��q r�s��V O8kRR c�s��W��VV YTpZ_� b d��q ������ � O8kR_ c�s��W��VV YTpZX� b d��q ������ � O8kRX

YTpZ̀�

��t W��u r�s��V 9!n#i6-.&)'253R̀

L)'%5#1%vw53&xJ%.3-&#8+%5.y3,z9�

��]�Vt�u� ��u _T�

RTZ_ �̂W�

�r

��t ¦�����t r�� g������������ �r �Vs�V��V d]� d]��t��W ��������V¦� §TTb��U_bZZ§� a]�u

ZUU_�

g���q��te t���q��t ��b�� s���̈ t���q��t �r �����t ©��������W �����e Zp �Vs�V��Vª�

���VV

r�s�� �V ����u«�t r�� ¬]����u q������ s��� � ��q�����tV su q�]��

����V��VV���

���q���� ��q��Vq��u ©���ª� r�� ��������V ��W]����t su

���VV���

����t��tV r�� \�«��t�]V ̂���]����Vª ��t r�]�t q������

��VV

���q��� ©ZTpª �Vs�V��V su ̂�����«�t ��W�� ��q��Vq��u ©̂��ª� d��� V�� �q�V ����s�� r�� �tt������� r��� ���V V���� s� �����t]q�t� �®q��� r]�� �r �����W�� �q� ��q� ���V �]V� s� ]V�t su q]V����� q���� ���t]q� q����r�q������ ��t��V����� su ��u �W��qu �r c�t���� ���V ��V� ������V ���u ����©Vª ��V��t�

��s ��t�e

J$m$Ok ��ḡ �� �Vs�V��V g���q��t� a�̄a���� �����]�t°

/3²23³3,#(.#8*'6)-2y3,#12́+%')-.z### µ¶·̧¹º»¼·̧½¹¾¿¹¿¶·»ÀÁ¹Â¶ÀÃÀ̧»ÄŽ¹Æ¼ÇÀÁ¼ÅÀÁȹɻÁ¶ÊÅÀÁ Ë̶ÍÀ·̧¹µ¼·̧½¹¿¶·»ÀÁ¹Â¶ÀÃÀ̧»Äʹ¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹

SECTION 8

SCHEMATIC DIAGRAM

Prepared By:

Compli√Chek Environmental 2709 Geert Ct Lansing, MI 48910

KITCHEN & LIVING RM

BATHROOM

BEDROOM

HALL

SITE:

WOOD FIBER CEILING

ROLLED FLOORING

ROLLED FLOORING (TOILET)

ASPHALT FLASHING PAPER

TOP HOUSE SHINGLE

BOTTOM HOUSE SHINGLE

Prepared For:

ABANDONED RESIDENTIAL PROPERTY

Cabin No. 17

USDA Forest Service Huron-Manistee National Forest 1755 South Mitchell St Cadillac, MI 49601-1143 CC Project No. DateMio, Michigan

Room / Space Equivalents

Materials Sampled for Asbestos

SECTION 8

SCHEMATIC DIAGRAM

2E

OSHA/MIOSHA Compliance Guidance

2E.1 OSHA/MIOSHA Requirements for Demolitions 2E.1

The NESHAPs rules were promulgated to protect the environment. Worker protection, work practices and hazard communication concerns are regulated by the Michigan Department of Labor and Economic Growth (DLEG) under the authority of Michigan Public Act 154. A brief OSHA/MIOSHA overview is provided for the client’s guidance:

(1).Thermal system and Surfacing ACM: (pipe, duct and boiler insulation, plasters, fireproofing, toweled materials)

• Must be removed by a licensed abatement contractor. There is an exception: a licensed trade group (residential builder or maintenance and alteration contractor) may remove small quantities without holding an abatement contractor’s license.

• Project notification if greater than 10 Linear / 15 Square feet

• 40-Hour-trained Competent Person must be licensed, present and annually trained

• 32- hour worker training and license required with annual refresher (excludes residential 10 units or less)

• Regulated area required

• Personal air monitoring until negative exposure assessment is established for each individual task associated with demolition.

• Wet methods

• Decon unit with shower

• Respirators and respiratory protection program

• Medical Surveillance

• Protective clothing

• Waste disposal (sealed impermeable containers)and waste hauling restrictions

• Engineering controls for partial interior demo (isolation / containment)

• Engineering controls for buildings where ACM remains in place without removal

(2). Demo when leaving 1 Non-Intact Class II ACM:

(roofing, flooring, mastics, caulks, glazings, siding materials, ceiling tiles, transite)

Note: When wallboard panels with ACM joint compound are removed, the work would be considered OSHA Class II. OSHA regards joint compound as finishing material. Provisions the employer must comply with include the methods of compliance provisions presented at 29 CFR 1926.1101(g)(1), (g)(2), (g)(3), and (g)(7) and at 29 CFR 1926.1101(g)(8)(v) or (vi); and the waste disposal provision at 29 CFR 1926.1101(l)(2).

• If the material is currently friable the demo contractor must be a licensed abatement contractor. There is an exception: a licensed trade group (residential builder or maintenance and alteration contractor) may remove small quantities without holding an abatement contractor’s license.

• DLEG project notification if greater than 10 Linear / 15 Square feet

• 40-Hour-trained Competent Person must be licensed, present and annually trained.

• Demo personnel must be 8-Hour-trained with annual refreshers

• Regulated area required

• Personal air monitoring until negative exposure assessment is established for each individual task associated with demolition.

• Wet methods

• Decon unit (drop cloth and HEPA vacuum) if no NEA

• Respirators and respiratory protection program

• Medical Surveillance

• Protective clothing

• Waste disposal (sealed impermeable containers)

• Waste hauling restrictions (if friable)

(3). Demo when leaving more than 1 Non-Intact Class II ACM: (roofing, flooring, mastics, caulks, glazings, siding materials, ceiling tiles, transite)

• If the material is currently friable the demo contractor must be a licensed abatement contractor. There is an exception: a licensed trade group (residential builder or maintenance and alteration contractor) may remove small quantities without holding an abatement contractor’s license.

• DLEG project notification if greater than 10 Linear / 15 Square feet

• 40-Hour-trained Competent Person must be licensed, present and annually trained.

• 32- hour worker training and license required with annual refresher on friable projects (excludes residential 10 units or less and exterior ACM projects)

• 8- hour worker training and license required with annual refresher on non-friable projects (excludes residential 10 units or less and exterior ACM projects)

• Regulated area required

• Personal air monitoring until negative exposure assessment is established for each individual task associated with demolition.

• Wet methods

• Decon unit (drop cloth and HEPA vacuum) if no NEA

• Respirators and respiratory protection program

• Medical Surveillance

• Protective clothing

• Waste disposal (sealed impermeable containers)

• Waste hauling restrictions (if friable)

2E.2 Building Owner and Employer/Contractor Responsibilities 2E.2

The MIOSHA Asbestos Standards for Construction, Part 602, requires pre-1981 building owners to conduct a thorough asbestos building survey. This survey must identify the presence, location and quantity of asbestos-containing material (ACM) and/or presumed asbestos-containing material (PACM) within the building. Once the building has been determined to have ACM/PACM, a contractor working in the facility must assess whether their work may require them to disturb or remove these materials during renovation/demolition activities. If so, they must comply with applicable work practices and procedures in Part 602. Contractors removing or encapsulating friable ACM/PACM may require licensing under the Michigan Asbestos Abatement Contractor Licensing Act (Act 135, P.A.

1986, as amended).

2E.3 MIOSHA Asbestos Regulations Overview 2E.3

MIOSHA Regulations Part 602:

• Requires an asbestos building/facility inspection in pre-1981 buildings.

• Obligates the building/facility owner to notify immediate employees and contractors working in facility of asbestos building/facility survey results.

• If the building survey is not available, obligates contractors/employers to presume suspect materials contain asbestos until a proper rebuttal through material sampling/analysis is performed.

• Specifies required work practices, protective equipment and procedures for employees removing and/or disturbing ACM and/or PACM.

• Requires asbestos awareness training for employees who may contact but not disturb ACM and/or PACM.

Training focuses on building materials that may contain asbestos to help assure that the building survey identified these materials and to prevent unintended disturbances.

Michigan Public Act 440 of 1988 (as amended), Asbestos Workers Accreditation Act:

• Requires persons who perform asbestos-related work in schools, school buildings, public and commercial buildings to be properly trained and accredited through the DLEG Asbestos Program, before performing the work (i.e., asbestos abatement workers, contractor/supervisors, building inspectors, management planners, and project designers).

• Requires trainers who train asbestos abatement workers, contractor/supervisors, building inspectors, management planners, and project designers in Michigan to be approved by the DLEG Asbestos Program before providing the training.

• Authorizes penalties and fines for violations of the Act.

• Authorizes the suspension, revocation, or denial of accreditation and trainer approval.

SAMPLING, ASSESSMENT, ANALYTICAL PROCEDURES

Sampling Methodology A minimum of two representative bulk samples are collected for each homogeneous miscellaneous material. Some materials, such as trowel-applied sprayed acoustics and fireproofing are sampled 3 or more times. Other materials that have been historically identified as asbestos-containing (Transite®, and pre-1940 pipe insulations) may be identified as presumed asbestos-containing materials (PACM). Each material is assigned a number (1,2,3,etc.) and each sample for the material is assigned an alpha designation (A,B,C, etc.). Homogenous material determination was based on the following criteria:

• Similar physical characteristics (same color and texture, etc.)

• Application (sprayed-on, troweled-on, assembly into a system, etc.)

• Material function (Thermal insulation, floor tile, wallboard system, etc.)

Assessment Methodology Material condition was assessed in order to categorize each material in accordance with the National Emissions Standard for Hazardous Air Pollutants (NESHAP; 40 CFR Part 61). The NESHAP Standard is the federal regulation governing the proper handling and disposal of ACMs(ACM) during demolition and renovation activities.

Material Quantities and Cost Estimating

Compli√Chek estimates quantities of all materials in the field in order to establish sampling requirements. Quantities of asbestos-containing materials are included in the final report. These quantities are visual estimates only, and may not include additional quantities that were concealed or inaccessible during the on-site survey. Cost estimates are averaged from 2 or more inquiries of abatement professionals in the field for similar work. Reported quantities are not intended for cost estimating purposes; any contractor wishing to bid abatement work related to these findings is required to establish quantities to their own satisfaction. Quantities of materials which yielded negatives for all samples are not reported.

PLM Analysis Methodology

TESC is a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory. Samples were analyzed consecutively by alpha designation until a positive result was recorded for that material, at which time further analyses for that material were halted and the material was then identified by the laboratory as positive. If the analyst received a negative result, all samples in that alpha series were analyzed and the material was then designated as negative for asbestos content. Analysis was performed by using the bulk sample for visual observation and slide preparation(s) for microscopic examination and identification. The samples were analyzed for asbestos (chrysotile, amosite, crocidolite, anthophyllite, and actinolite/tremolite), as well as fibrous non-asbestos constituents (mineral wool, cellulose, etc.) and non-fibrous constituents. Using a stereoscope, the microscopist visually estimated relative amounts of each constituent by determining the volume of each constituent in proportion to the total volume of the sample.

Laboratory Services were provided by:

Triangle Environmental Service Center (TESC) 15549 Fox Cove Circle Mosely, VA 23120

Physical or Other Limitations Some areas were not accessed during the on-site investigation. These areas are described as follows:

• Trenches, voids, crocks below grade (would require demolition for access)

PAINT TESTING USING XRF INSTRUMENTATION

XRF TESTING METHODOLOGY: XRF technology uses low- level radiation to induce energy in lead atoms within a painted surface, which the XRF unit is able to analyze. The device then displays the results in milligrams of lead per square centimeter of surface area tested (mg/cm

), and is able to determine if LBP is present. LBP is defined by State and Federal regulations as surface coatings that contain 1.0 mg/cm of lead, or greater. The XRF unit is operated in accordance with the Performance

Characteristic Sheet (PCS), retained and stored with the XRF Unit.

XRF Unit Number: 1560; resource date : 04-18-13

O M

ROOM EQUIVALENT

W A

B S

T R

A

COMPONENT

E

A D

IN

G

(m g

/cm 2)

P O

S / N

G

NA CALIBRATION READING NIST BLOCK 1.0 NA NA NA 1.1 NA

NA CALIBRATION READING NIST BLOCK 1.0 NA NA NA 1.1 NA

NA CALIBRATION READING NIST BLOCK 1.0 NA NA NA 1.2 NA

EX-1 HOUSE EXTERIOR A WOOD EXTERIOR WALL 0.6 NEG

EX-1 HOUSE EXTERIOR B WOOD EXTERIOR WALL 0.3 NEG

EX-1 HOUSE EXTERIOR C WOOD EXTERIOR WALL 0.3 NEG

EX-1 HOUSE EXTERIOR D WOOD EXTERIOR WALL 0.0 NEG

EX-1 HOUSE EXTERIOR B WOOD HOUSE SOFFIT 0.3 NEG

1 KITCHEN & LIVING RM B WOOD TOP CABINET FRAME 0.0 NEG

1 KITCHEN & LIVING RM B WOOD TOP CABINET DOOR 0.1 NEG

1 KITCHEN & LIVING RM B WOOD BOTTOM CABINET FRAME 0.1 NEG

1 KITCHEN & LIVING RM B WOOD BOTTOM CABINET DOOR 0.3 NEG

1 KITCHEN & LIVING RM B WOOD KITCHEN LIVING ROOM WEST WALL 0.0 NEG

1 KITCHEN & LIVING RM C WOOD KITCHEN LIVING ROOM NORTH WALL 0.2 NEG

1 KITCHEN & LIVING RM D WOOD KITCHEN LIVING ROOM EAST WALL 0.3 NEG

1 KITCHEN & LIVING RM A WOOD KITCHENLIVING ROOM SOUTH WALL 0.0 NEG

EX-1 HOUSE EXTERIOR X WOOD SCREEN DOOR EXTERIOR 0.4 NEG

EX-1 HOUSE EXTERIOR X WOOD SCREEN DOOR INTERIOR 0.0 NEG

EX-1 HOUSE EXTERIOR X WOOD HOUSE DOOR EXTERIOR 0.3 NEG

EX-1 HOUSE EXTERIOR X WOOD HOUSE DOOR JAMB 0.3 NEG

INSPECTOR AND LABORATORY ACCREDITATION

File details come from the government source that posted it. Updated .