Allen.pdf

PDF 2 MB Posted

Attached to
HM - Noontime Demolition Project Federal contract opportunity
Solicitation number
AG-569R-S-14-0040
Issued by
Department of Agriculture Forest Service R9-Eastern Region

About this file

Attachment 8 - Allen Site

View the file

Other files for this federal contract opportunity

Other files attached to HM - Noontime Demolition Project, newest first.
File Type Posted
Oakey_Report_doc.pdf PDF
Hess.pdf PDF
Experience_Questionnaire.doc DOC document
Fountain.pdf PDF
Noontime_Maps.pdf PDF
Cline_Property.pdf PDF
AG-569R-S-14-0040.rtf RTF text file
Ahlborn.pdf PDF
05-2271.txt TXT text file
Noontime_Pictures.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

07-07-10

Agency:

Huron-Manistee National Forest

Attn: Russ Sutton, P.E., Facilities

Engineer

1755 South Mitchell Street

Cadillac, MI 49601

Regarding: Pre-Demo Survey

Structure: Vacant Residential Property

Location: Mio, Michigan

Former Aline Residence

Project No: 063010-2

Project Date: 06-30-10

Dear Client:

In accordance with our agreement, Compli√Chek Environmental Compliance, LLC (C√C) has conducted a pre-demolition asbestos survey and comprehensive paint testing at the above property. This survey was conducted on 06-30-10 by Burt Russell, a Michigan-licensed asbestos inspector (No. A5519), and Lead Risk Assessor (No. P00187).

Compli√Chek appreciates the opportunity to provide environmental services on this project.

Should you need additional services on this or any other project, please feel free to call us.

Respectfully submitted, Compli√Chek, LLC

Burt Russell

Project Specialist

PRE-DEMOLITION ASBESTOS SURVEY

and LEAD-BASED PAINT INSPECTION

Vacant Residential Property

Mio, Michigan

Former Aline Residence

PREPARED FOR: Huron-Manistee National Forest

1755 South Mitchell Street

Cadillac, MI 49601

PREPARED BY: Compli-Chek ASSESSOR: Burt Russell 2709 Geert Court MI No. P-0187 Lansing, MI 48910

PROJECT DATE: 06-30-10 REPORT DATE: 07-07-10

Burt R. Russell

MI Asbestos Inspector # AA5519

MI Lead Risk Assessor # P00187

COMPLIa CHEK LLC 2709 GEERT COURT LANSING, MI 48910 (517) 507-2547 C-C Project No. 063010-2

Table of Contents

Report Section

Project Summary

Interpretation of Results and Regulatory Guidelines

Space / Material Inventory

Material Sampling / Asbestos Content

Laboratory Analytical Reports

Asbestos Sampling and Analytical Procedures

Inspector and Laboratory Certification

Schematic Drawing

Paint Testing by X-Ray Florescence

PROJECT SUMMARY

SECTION 1

1.0 PROJECT OVERVIEW

Compli√Chek, LLC (C√C) has conducted a Pre-Demolition Survey at Mio, Michigan, GGG. The survey performed at the subject site encompassed all interior / exterior spaces and identified all building components with respect to asbestos and lead-based paint. The inspector performed a space-by space survey of materials and their locations, employing destructive methods in order to locate and sample concealed materials. Section 1 of the report summarizes the findings of the asbestos survey. Section 2 details steps to comply with NESHAPs requirements (defined below).

Section 3 locates and quantifies all materials within designated spaces. Section 4 identifies asbestos sample locations and summarizes analytical results with all laboratory findings following in Section 5.

Compli√Chek uses assessment, sampling and analytical procedures standardized in 1987 by the EPA

Asbestos Hazards Emergency Response Act, (40 CFR 763 Subpart M; AHERA). These methodologies are summarized in Section 6. The Michigan–licensed inspector on this project was

Burt Russell; copies of all accreditation are located in Section 7. A Schematic drawing of the structures located on the property is located at Section 8. Additional X-Ray florescence testing of all painted components found on the property is located at Section 9.

1.2 PROJECT SCOPE

The requirements for performing a pre-demolition or pre-renovation survey are found in Federal

Standard Number 40 CFR 61, entitled: National Emissions Standards for Hazardous Air

Pollutants (NESHAP). The NESHAP standards require that, prior to a renovation or demolition activity, all materials which could potentially contain asbestos must be designated as one of the following:

• NACM (Nonasbestos-Containing Material)

1. materials containing less than 1% asbestos

• RACM (Regulated Asbestos-Containing Materials)

� Friable ACM

� Category 1 ACM that has become friable or will be subject to sanding, grinding, cutting or abrading

� Category 2 ACM that is likely to or has become crumbled, pulverized or reduced to powder by renovation or demolition activities.

RACM must always be removed from the structure before demolition or, if it will be disturbed, before renovation. This is further clarified in Section 2 of the report.

• NCAT-1 (NESHAP CATegory- 1 non-friable material)

� gaskets, packings, flooring, asphalt roofing products containing more than 1% asbestos).

Some NCAT-1 materials may remain in the structure during a demolition if they are not friable prior to the demolition. This is further clarified in Section 2 of the report.

• NCAT-2 (NESHAP CATegory- 2 non-friable material)

� Any ACM, excluding Category 1, containing more than 1% asbestos that, when dry, cannot be crumbled, pulverized or reduced to powder by hand pressure.

Some NCAT-2 materials may remain in the structure during a demolition if they are not friable prior to the demolition. This is further clarified in Section 2 of the report.

RESULTS AND REGULATORY GUIDELINES

SECTION 2

A material is considered by the Environmental Protection Agency (EPA) and the State of Michigan, Department of Labor and Economic Growth to be an asbestos-containing material (ACM) if at least one analysis from a collected sample yields a result greater than 1% asbestos (chrysotile, amosite, tremolite, crocidolite), or, if a material is assumed to contain asbestos based on the knowledge and observation of the licensed inspector. The client may, at any time, choose to rebut a positive assumption with confirmatory analysis of three samples of the material, stopping further analysis on the first positive sample. The client must treat any ACM material as an assumed asbestos-containing material and forego any analysis.

2A Non-regulated materials identified during survey testing <1% 2A

(Detailed in Sub-Sections 3A/4A)

All materials sampled during the survey yielded analytical results of less than 1% asbestos. ACMs are not present within the project area. No regulatory requirements under the NESHAPs are applicable to renovation/demo tasks associated with this project with the following exception: The Reno/Demo contractor is required to submit a Notice of Intent to Demolish to the Michigan Department of

Environmental Quality at least 10 working days prior to demolition.

MDLEG Notification:

< 10 Linear Feet or 15 Square Feet (Notification not required)

> 10 Linear Feet or 15 Square Feet (10-Calendar-day notification; OSHA regulations apply)

NESHAP (DEQ) Notification:

< 260 Lin Ft or 160 Sq Ft (Notification required; no further NESHAP requirements)

>/= 260 Lin Ft or 160 Sq Ft (10-Working day notification required; NESHAP requirements apply)

SPACE / MATERIAL INVENTORY

SECTION 3

S P A C E

N U M B

R

SPACE DESCRIPTION

M A T E R

IA

L

M B

MATERIAL DESCRIPTION

A T E R

T Y

A T E R

O N D

IT

IO

S H

T E G O

R C E

B E S T

F /N

Q

A N T

IT

IT

A S U

3A NACM: Non-Asbestos-Containing Materials (Testing <1%) 3A

EX1 GARAGE EXTERIOR 1 GARAGE ASPHALT WALL SHINGLE MM POOR NA ND NF 530 SF

EX1 GARAGE EXTERIOR 4 GARAGE ROOF SHINGLE MM POOR NA ND NF 220 SF

EX2 HOUSE EXTERIOR: ADDITION 2 RECENT WINDOW GLAZING MM FAIR NA ND NF 1 WDW

EX3 HOUSE EXTERIOR: ORIGINAL 5 HOUSE ROOF SHINGLE MM POOR NA ND NF 1400 SF

EX3 HOUSE EXTERIOR: ORIGINAL 3 ORIGINAL WINDOW GLAZING MM FAIR NA ND F 1 WDW

1 HOUSE INTERIOR 6 WOOD FIBERBOARD CEILING MM POOR NA ND F 140 SF

3B RACM: NESHAP Regulated Asbestos-Containing Materials NONE OBSERVED 3B

3C NCAT-1 & NCAT-2 Materials That May Become Friable During Demo/Reno NONE OBSERVED 3C

3D NCAT-1 & NCAT-2 Materials That May Remain in Building During Demo/Reno NONE OBSERVED 3D

MATERIAL SAMPLING

SECTION 4

MATERIAL #1: HOUSE / GARAGE ASPHALT WALL SHINGLE

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

01 A GARAGE SIDE D NONE DETECTED NA

01 B HOUSE SIDE D NONE DETECTED NA

01 C HOUSE SIDE B BACK PART NONE DETECTED NA

MATERIAL #2: RECENT WINDOW GLAZING

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

02 A HOUSE SIDE A ADDITION NONE DETECTED NA

MATERIAL #3: ORIGINAL WINDOW GLAZING

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

03 A SIDE B BACK PORTION NONE DETECTED NA

03 B SIDE A FRONT PART NONE DETECTED NA

03 C ORIGINAL HOUSE SIDE D NONE DETECTED NA

MATERIAL #4: GARAGE ROOF SHINGLE

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

04 A GARAGE CORNER SIDES A/D NONE DETECTED NA

04 B GARAGE SIDE D NONE DETECTED NA

MATERIAL #5: HOUSE ROOF SHINGLE

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

05 A HOUSE SIDE A ADDITION NONE DETECTED NA

05 B HOUSE FRONT PORTICO NONE DETECTED NA

05 C HOUSE SIDE D ORIGINAL NONE DETECTED NA

MATERIAL #6: WOOD FIBERBOARD CEILING

SAMPLE # SAMPLE LOCATION ASBESTOS PRESENT ? TYPE

06 A CENTER ROOM NONE DETECTED NA

LABORATORY ANALYTICAL REPORTS

SECTION 5

������ !"#$%&'#()*+,%-.#/)%,0##1*2'3#(0##42,5)'62%+0#78#9���9###########################################################################################:;<=>?@=A>BACDCEFGHC:;<=>?@=A>B?C##(IJK#81($1LM1#184NJ$#8O8JP1Q1#1I448/P#############################################################################################RSTU ������V��W�

XYUZT![�!�!\9�����

]������̂ ZTTSTR�S_R_RTZTS_R_RTZTS_R_RTZT�̀

a���Wa�b ����c ���� dce��� �����]�ce��� ����f���ce��� ��]���c����f��cL$1g184NJ$#h gJQ$OL#184NJ$#Qij#k/M11#i$1g/QNLQMO $1LQ48L$il#81($1LM1 OMO#81($1LM1l#mQ($/1 OMO#mQ(/MI1l#48L$/Q8J1������c������ a�b_ dcZ Z� b��n ������ � O8i YToRTo ����p��V�

R Zb b��n ������ � O8i YToRTo q Z� b��n ������ � O8i YToRTo

X R� r���� �pss�� O8i ZTTo t q�

�uu�v���� ��vw�� O8i UYoRo x qb

�uu�v����

S q�

�uu�v����

Y X� b��n ������ � O8i YToRTo

U Xb b��n ������ � O8i YToRTo

ZT t� b��n ������ � O8i YToRTo ̀�s��W��VV

�̀�w�̂� ap�̂

TR�

RTZT ]�W�

Z �u Ryz{|}~��z�~�z�z}��~�����z�����z��~����������~��{��~�����������~��~�~�{��z�����������~����������}������}z�����yz{|}~��������������� �¡¡���¢�}��¡�� £�]��xTT_�X�YR�TRT� e�n

ZUYR¤�

np����� �����w u�� ����̂V�V �u �Vs�V��V sp��w��W e���n��wc w���n��w s���v��� w���n��w �u �����w £��������W �����c Zo �Vs�V��V¤�

���VV

u�s�� �V ����̂¦�w u�� §p����̂ n������ s��� � ��n�����wV ŝ n�p��

������V��VV���

���n���� ��n��Vn��̂ u�� ��������V ��Wp����w ŝ

���VV���

����w��wV u�� ̈�¦��w�pV ]���p����V¤ ��wu�p�w n������

��VV

���n��� £©ZTo¤ �Vs�V��V ŝ ]�����¦�w ��W�� ��n��Vn��̂ b��� V�� �n�V ����s�� u�� �ww������� u��� ���V �������pV� s� �����wpn�w �ªn��� up�� v��� �u �����W�� �n� ��n� ���V ��V� ������V ����£V¤ ��V��w�����] ��s ��w�c

RTTSUX�T

J$k$Oi ��e«�� �Vs�V��V e���n��w� �����«������p�� a�«a���� �����p�w¬

/3®23̄3,#(.#8*'6)-2°3,#12±+%')-.²### ³́µ¶·̧¹ºµ¶»·¼½·½́µ¹¾¿·À́¾Á¾¶¹Âû·ÄºÅ¾¿ºÃ¾¿Æ·Ç¹¿́Èþ¿ÉẾ˾µ¶·³ºµ¶»·½́µ¹¾¿·À́¾Á¾¶¹Â÷············································

������ !"#$%&'#()*+,%-.#/)%,0##1*2'3#(0##42,5)'62%+0#78#9���9###########################################################################################:;<=>?@=A>BACDCEFGHC:;<=>?@=A>B?C##(IJK#81($1LM1#184NJ$#8O8JP1Q1#1I448/P#############################################################################################RSTU ������V��W�

XYUZT![�!�!\9�����

]������̂ ZTTSTR�S_R_RTZTS_R_RTZTS_R_RTZT�̀

a���Wa�b ����c ���� dce��� �����]�ce��� ����f���ce��� ��]���c����f��cL$1g184NJ$#h gJQ$OL#184NJ$#Qij#k/M11#i$1g/QNLQMO $1LQ48L$il#81($1LM1 OMO#81($1LM1l#mQ($/1 OMO#mQ(/MI1l#48L$/Q8J1������c������ a�b_ dcZZ nb b��o ������ � O8i YTpRTp ̀�q��W��VV

ZR n� b��o ������ � O8i YTpRTp ̀�q��W��VV

Zr s� b��t� u�q��V O8i RpUYp ����v��V�

L)'%5#1%wx53&yJ%.3-&#8+%5.z3,{���̀�|�̂� av�̂

TR�

RTZT ]�W�

R �u R}~������~���~�~���������~�����~�����������������������������������������~������������������������������~�����}~������������� �¡¢£¤¢¥¥���¦����¥££¤§�]��sTT_�X�YR�TRT� e�o

ZUYR̈�

ov����� u�� ����̂V�V �u �Vq�V��V qv��|��W e���o��|c |���o��| q���t��� |���o��| �u §��������W �����c Zp �Vq�V��V̈�

���VV

u�q�� �V ����̂ª�| u�� «v����̂ o������ q��� � ��o�����|V q̂ o�v��

������V��VV���

���o���� ��o��Vo��̂ u�� ��������V ��Wv����| q̂

���VV���

����|��|V u�� ¬�ª��|�vV ]���v����V̈ ��|u�v�| o������

��VV

���o��� §ZTp̈ �Vq�V��V q̂ ]�����ª�| ��W�� ��o��Vo��̂ b��� V�� �o�V ����q�� u�� u��� ���V �������vV� q� �����|vo�| �®o��� uv�� t��� �u �����W�� �o� ��o� ���V ��V� ������V ����§V̈ ��V��|�����] ��q ��|�c

RTTSUX�T

J$k$Oi ��ē �� �Vq�V��V e���o��|� �����̄������v�� a�̄a���� �����v�|°

±/3²23³3,#(.#8*'6)-2z3,#12́+%')-.{### µ¶·̧¹º»¼·̧½¹¾¿¹¿¶·»ÀÁ¹Â¶ÀÃÀ̧»ÄŽ¹Æ¼ÇÀÁ¼ÅÀÁȹɻÁ¶ÊÅÀÁË̶ÍÀ·̧¹µ¼·̧½¹¿¶·»ÀÁ¹Â¶ÀÃÀ̧»Äʹ¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹¹

SAMPLING, ASSESSMENT, ANALYTICAL PROCEDURES

SECTION 6

Sampling Methodology

A minimum of three representative bulk samples were collected for each homogeneous material.

Each homogeneous material was assigned a number (1,2,3,etc.) and each sample for the material was assigned an alpha designation (A,B,C, etc.). Homogenous material determination was based on the following criteria:

• Similar physical characteristics (same color and texture, etc.)

• Application (sprayed-on, troweled-on, assembly into a system, etc.)

• Material function (Thermal insulation, floor tile, wallboard system, etc.)

Assessment Methodology

Material condition was assessed in order to categorize each material in accordance with the National

Emissions Standard for Hazardous Air Pollutants (NESHAP; 40 CFR Part 61). The NESHAP

Standard is the federal regulation governing the proper handling and disposal of ACMs(ACM) during demolition and renovation activities.

PLM Analysis Methodology

Laboratory Services were provided by:

Triangle Environmental Service Center (TESC)

15549 Fox Cove Circle

Mosely, VA 23120, TESC is a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory.

Samples were analyzed consecutively by alpha designation until a positive result was recorded for that material, at which time further analyses for that material were halted and the material was then identified by the laboratory as positive. If the analyst received a negative result, all samples in that alpha series were analyzed and the material was then designated as negative for asbestos content.

Analysis was performed by using the bulk sample for visual observation and slide preparation(s) for microscopic examination and identification. The samples were analyzed for asbestos (chrysotile, amosite, crocidolite, anthophyllite, and actinolite/tremolite), as well as fibrous non-asbestos constituents (mineral wool, cellulose, etc.) and non-fibrous constituents. Using a stereoscope, the microscopist visually estimated relative amounts of each constituent by determining the volume of each constituent in proportion to the total volume of the sample.

Physical or Other Limitations

Some areas were not accessed during the on-site investigation. These areas are described as follows:

• Trenches, voids, crocks below grade (would require demolition for access)

INSPECTOR AND LABORATORY ACCREDITATION

SECTION 7

C-C appreciates the opportunity to provide environmental consulting services on this project and we look forward to working with you again in the future. C-C provides additional consulting services, which include abatement project planning and lead/asbestos post-abatement clearance, asbestos and lead inspection/assessment services and environmental audit consultation. If you have any questions please feel free to call us at 517-

507-2547 to discuss this project or any of the services listed above.

SECTION 8

SCHEMATIC DIAGRAM

Prepared By:

Compli√Chek Environmental 2709 Geert Ct Lansing, MI 48910

KITCHEN AND DINING ROOM

LIVING ROOM

BEDROOM

ENTRY AREA

SITE:

GARAGE ASPHALT WALL SHINGLE

RECENT WINDOW GLAZING

FIBERBOARD CEILING

ORIGINAL WINDOW GLAZING

GARAGE ROOF SHINGLE

HOUSE ROOF SHINGLE

Prepared For:

Vacant Property

Former Aline Residence

Huron Manistee National Forest 1755 SouthMitchell Street Cadillac, Michigan 49601

CC Project No. Date

063010-2 30-Jun-10

Mio, Michigan

GARAGE

Room / Space Equivalents

1 4

C

D B

A

Materials Sampled for Asbestos

N S

E

W

SECTION 8

SCHEMATIC DIAGRAM

PAINT TESTING

SECTION 9

PAINT TESTING: Scope and Limitations The methodology used in this project for lead-based paint identification is detailed in the U. S. Department of Housing and Urban Development (HUD) Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing Chapter 7 : Lead-Based Paint Inspection (1997 Revision). The XRF unit currently in use by the inspector is an RMD LPA-1, Serial No. 1053. The unit is operated in accordance with the Performance Characteristic Sheet (PCS) included in section K of this report. The LPA-1 does not require substrate correction when operated in standard mode with the exception of metal substrates which are read in quick mode in accordance with the PCS sheet. XRF technology uses low- level radiation to induce energy in lead atoms within a painted surface, which the XRF unit is able to analyze. The device then displays the direct-reading results in milligrams of lead per square centimeter of surface area tested (mg/cm

), and is able to determine if

LBP is present. LBP is defined by State and Federal regulations as surface coatings that contain 1.0 mg/cm of lead, or greater.

M B

BUILDING DESCRIPTION ROOM EQUIVALENT

ID

B S T R A

COMPONENT

E A D

IN

G

S / N

G

NA CALIBRATE: 1.0 NIST BLOCK NA NA WOOD NA 1.0 NA

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR B WOOD WNDW CASING 0.1 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR B WOOD WINDOW SILL 0.1 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR B WOOD WINDOW SASH 0.1 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR A WOOD FASCIA 0.3 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR A WOOD SOFFIT 0.1 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR B WOOD FASCIA 0.0 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR B WOOD SOFFIT 0.0 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR A WOOD STORM WNDW SASH 0.1 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR A WOOD HOUSE WNDW SASH 0.1 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR A WOOD KITCHEN STORM SASH 0.0 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR A WOOD KITCHEN WNDW SASH 0.2 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR A METAL STOVE EXHAUST 0.4 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR A WOOD PORTICO FRAMING 0.3 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR A WOOD PORTICO CEILING 0.0 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR D WOOD SOFFIT 0.6 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR D WOOD FASCIA 0.2 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR D WOOD BLUE WINDOW CASING 0.8 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR C WOOD FASCIA 0.3 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR C WOOD SOFFIT 0.1 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR C WOOD WINDOW SILL 0.1 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR C WOOD WINDOW SASH 0.1 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR C WOOD WINDOW CASING 0.3 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR C WOOD PICTURE WINDOW CASING 0.4 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR C WOOD PICTURE WNDW FRAMING 0.0 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR C WOOD FASCIA 0.4 NEG

EX1 ALINE PROPERTY HOUSE ADDITION EXTERIOR C WOOD SOFFIT 0.0 NEG

EX2 ALINE PROPERTY ORIGINAL HOUSE EXTERIOR C WOOD FREE STANDING SCREEN DOOR 3.3 POS

EX3 ALINE PROPERTY ALINE GARAGE C WOOD CORNER TRIM 1.3 POS

EX3 ALINE PROPERTY ALINE GARAGE D WOOD SOFFIT 1.2 NEG

EX3 ALINE PROPERTY ALINE GARAGE C WOOD GARAGE DOOR 0.3 NEG

EX3 ALINE PROPERTY ALINE GARAGE B WOOD WINDOW CASING 0.0 NEG

EX3 ALINE PROPERTY ALINE GARAGE B WOOD WINDOW SASH 0.7 NEG

EX3 ALINE PROPERTY ALINE GARAGE D WOOD WINDOW CASING 0.3 NEG

EX3 ALINE PROPERTY ALINE GARAGE D WOOD WINDOW SASH 0.3 NEG

EX4 ALINE PROPERTY OUTHOUSE D WOOD WALL 0.3 NEG

File details come from the government source that posted it. Updated .