Window Assessment Photos 2 .pdf
PDF 2 MB Posted
- Solicitation number
- AG-4419-S-10-0705
About this file
Photo 2
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pre-Bid Meeting Notes-Documents.doc | DOC document | |
| SF 30 Amendment 1.pdf | ||
| SF 1442 Cont 0705.docx | DOCX document | |
| Standards Guidelines.pdf | ||
| Houston and Ava Lead inspection report.pdf | ||
| SF 1442 - Solicitation Cover Pg.pdf | ||
| Specifications.rtf | RTF text file | |
| Methods of Reducing Lead-Paint Hazards in HH.pdf | ||
| DBA.pdf | ||
| Window Assessment Photo 1.pdf | ||
| Experience Capability Statement 0705.doc | DOC document | |
| Schedule of Items.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Window Survey Mark Twain National Forest, Ranger Station
Ava, Missouri
The Ava Ranger Station has four stone buildings.
The Warehouse has/had three wooden gable windows. Two of three are original 9-light, wood sash are top hinged. #1 & #3 show the original 9-light sash which are repairable. Sash #2 is missing and should be replaced with top hinged sashes to match the design of #1. The ground floor Warehouse window openings are made up of two 6-light wooden sashes that are opened by sliding them horizontally in a wood track. All of these openings are repairable with some minor wood track repairs and all the other specifications applied to the double hung window specifications. The Marvin “Wood Combination Window” storm is installed vertically as if attached over a normal double hung window.
Warehouse Westside
Window # 1
Deferred Maintenance- Admin Facilities- Ava Admin Site Window Restoration CIM-0900-15F-190-0905-06 agarrison Typewritten Text agarrison Typewritten Text agarrison Typewritten Text
Warehouse North Side
Warehouse Eastside
Window # 10
Window # 8
Window # 9
Window # 7
Window # 6
Window # 2
Window # 5 Window # 4
Warehouse, Southside
Window # 3
Window # 12
Window # 11
Window # 7
Window # 6
North Building, West Side
North Building, North Side
North Building, East Side
Window # 1-a Window # 1-b
Window # 11
Window # 10 Window # 9
Window # 8
Window # 12 Window # 14
Window # 13
North Building, South Side
Window # 2-a Window # 2-b
Window # 5
Window # 4
Window # 3
Window # 2
Window # 3 Window # 4
Window # 14
Window # 13 Window # 12
Window # 11
Window # 10
South Building, West Side
South Building, North Side
South Building, East Side
Window # 5
Window # 19
Window # 18
Window # 17
Window # 16
Window # 15
Window # 6
Window # 22
Window # 21
Window # 20
South Building, South Side
Window # 9 Window # 8
Window # 7
Garage, North Side
Garage, East Side
Window # 3 Window # 2
Garage, South Side
Each window opening is rated under the following criteria:
1) Not repairable or missing. A new true divided light, single pane, wooden sash kit should be installed in original jamb with Marvin’s “Wood Combination Window” storm.
2) Average Repair. Minor architectural epoxy repairs; broken glass replacement; paint removal both sides of sashes and jamb; glazing putty removal; new sash ropes or horizontal wood track repair; new or salvaged sash weights & pulleys; new paint; a Marvin “Wood Combination Window” storm.
3) Minor Repair. Broken glass replacement; exterior paint removal on the sashes and jamb only; glazing putty removal; new sash ropes or horizontal wood track repair; new paint; a Marvin “Wood Combination Window” storm.
NOTE: “Estimated Cost of Repair” includes a Marvin “Wood Combination Window” storm.
Ava Structure Window # Rating Comments Warehouse 1 2 “ 2 1 “ 3 2 “ 4 2 “ 5 2 Repair Muntin “ 6 2 Minor epoxy repair “ 7 2 Minor epoxy repair “ 8 2 Minor epoxy repair “ 9 2 Minor epoxy repair “ 10 2 Minor epoxy repair “ 11 3 “ 12 3
Window # 4
North Building 1 3 “ “ “ 2 3 “ “ “ 3 3 “ “ “ 4 3 “ “ “ 5 3 “ “ “ 6 3 “ “ “ 7 3 “ “ “ 8 3 “ “ “ 9 3 “ “ “ 10 3 “ “ “ 11 3 “ “ “ 12 3 “ “ “ 13 3 “ “ “ 14 3 South Building 1 3 “ “ “ 2 3 “ “ “ 3 3 “ “ “ 4 3 “ “ “ 5 3 “ “ “ 6 3 “ “ “ 7 3 “ “ “ 8 3 “ “ “ 9 3 “ “ “ 10 3 “ “ “ 11 3 “ “ “ 12 3 “ “ “ 13 3 “ “ “ 14 3 “ “ “ 15 3 “ “ “ 16 3 “ “ “ 17 3 “ “ “ 18 3 “ “ “ 19 3 “ “ “ 20 3 “ “ “ 21 3 “ “ “ 22 3
Garage 1 2 “ 2 3 “ 3 3 “ 4 2 Bottom sash is reversed