Text version

PONDING HEIGHT

FLOW

F

L

O

W

24" MIN.

STEEL

TRENCH DETAIL

FILTER FABRIC SHALL BE IN ACCORDANCE

WITH CONSTRUCTION SPECIFICATIONS

STEEL POST

5 FT. POST LENGTH (MIN.), 1.25 LBS./FT. WEIGHT

(MIN.) 1-3/8 INCHES WIDE (MIN.), 14 SQUARE

INCHES ANCHOR PLATE SURFACE AREA (MIN.)

MAX. SEDIMENT LEVEL 0.25 FT.

36" MIN.

ATTACH FABRIC TO POSTS IN

ACCORDANCE WITH CONSTRUCTION

SPECIFICATIONS

NOTE:

1. SILT FENCE SHALL BE PLACED ON SLOPE CONTOURS TO MAXIMIZE PONDING EFFICIENCY.

2. INSPECT AND REPAIR FENCE AFTER EACH STORM EVENT AND REMOVE SEDIMENT WHEN

NECESSARY. 0.5 FT. MAXIMUM RECOMMENDED STORAGE HEIGHT.

3. REMOVED SEDIMENT SHALL BE DEPOSITED IN SPOIL AREA AS SHOWN ON CONSTRUCTION

DRAWINGS.

4"X8" TRENCH WITH

COMPACTED BACKFILL

8' MAXIMUM SPACING WITH WIRE

SUPPORT FENCE; 6' MAXIMUM SPACING

WITHOUT WIRE SUPPORT FENCE

ATTACH FILTER FABRIC

SECURELY TO UPSTREAM

SIDE OF POST

" H.G.

BALLAST CHAIN

FOR WEIGHT

FLOTATION

CHAIN TENSIONED THROUGH

S.S. STRESS PLATES, VIA

HOOK AND RING CONNECTION

ANCHOR POINTS

CURTAIN MEMBRANE

ANCHOR POINTS

" GAL

CABLE

CHANNEL BOTTOM

FLOW DIRECTION

CHANNEL BANK

CHANNEL BANK

TURBIDITY CURTAIN

EXTENDS TO BOTTOM

OF CHANNEL

ANCHOR POINTS

ANCHOR POINTS

SECTION VIEW

PLAN VIEW

NOTE: INSTALL AND MAINTAIN TURBIDITY CURTAIN IN ACCORDANCE WITH MANUFACTURE'S

SPECIFICATIONS. CONTRACTOR SHALL SUBMIT TO ENGINEER THE PRODUCT CUT SHEET,

INSTALLATION SPECIFICATIONS, AS WELL AS A MAINTENANCE PLAN/SCHEDULE FOR REVIEW

AND CONCURRENCE. ANCHORING STRUCTURES SHALL BE CONSTRUCTED AND/OR

INSTALLED PER MANUFACTURE'S RECOMMENDATIONS FOR PROPER LATERAL FORCE

REQUIREMENTS.

MIN. 20.0' BERM

1 1

VARIES

MIN. 20.0' BERM

M

A X

DESIGNED BORROW AREA

VARIES

LIMITS OF DISTURBANCE PER PLANS AND SPECIFICATIONS

V A

R I E

S

DEBRIS AND SPOIL AREA

TYPICAL BORROW AREA CROSS-SECTION

M

A X

VARIES

DEBRIS AND SPOIL AREA

(NTS.)

MAX. DEPTH 4.0 FEET AFTER

CLOSING THE BORROW AREA

C

LIFTING HOLE

REF.

B DIA.

O.D.

BOLT DIA. = M

PROJECTION = P

BOLT CIRCLE = BC.

22 1/2 °

22 1/2 °

22 1/2 °

22 1/2 °

A DIA.

D2

No. NAME

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

FRAME

SEAT

RETAINER RING

HEX HEAD BOLT / NUT

COVER

HINGE ARM

PIVOT LUG

HINGE PIN

BUSHING

WASHER

SPRING PIN

HEX HEAD BOLT / NUT

6" CONCRETE HEADWALL

DESIGNED BY FABRICATION

ENGINEER

DEADMAN

(TYP.)

PROPOSED 5' X 4' WATER CONTROL STRUCTURE

PROPOSED 57 STONE SUBGRADE

PROPOSED TIDEGATE

CONNECTING CABLE

(TYP.)

HEADWALL FOOTING BELOW

(TYP.)

PROPOSED PIPE

TOE OF SLOPE

AREA OF SLOPE PROTECTION CLASS A RIP-RAP

SHALL BE PLACED 5 FOOT PAST THE TOE OF SLOPE

TO THE TOP OF THE RISER. ELEVATION DEPTH

OF STONE SHALL BE 18 INCHES. STONE SHALL BE

UNDER LAID WITH NON-WOVEN GEO-TEXTILE.

TOP OF STRUCTURE ELEVATION

TYPICAL SLOPE PROTECTION FOR

BOTH HEADWALL / ENDWALL

TOE OF SLOPE

NON-WOVEN

GEO-TEXTILE

TOP OF STRUCTURE

ELEVATION

TOE OF SLOPE

NON-WOVEN

GEO-TEXTILE

TOP OF STRUCTURE

ELEVATION

2:1 MAX. SIDE SLOPE

2:1 MAX. SIDE SLOPE

PROPOSED HEADWALL / ENDWALL

PROPOSED STRUCTURE

PROPOSED STRUCTURE

PROPOSED HEADWALL / ENDWALL

NTS

SILT FENCE

BAR IS ONE INCH ON

ORIGINAL DRAWING

0 1"

DATE:

PROJ:

DWG:

VERIFY SCALE

SCALE AS SHOWN

W E

T L

A N

D

R

E S

E R

V E

P

R O

G R

A M

O U

T F

A L

L

F

A R

M S

D E

T A

I L S

A

N D

T

Y P

I C

A L

S

E C

T I O

N

SHEET: of 15

9/14/2012

D S

G N

D

R

C H

K

A P

V D

N o

D E

S C

R I P

T I O

N A

P V

D B

Y D

A T

E

J D

H S

D L

T L R

J D

H

I S

S U

F

O

B

I

C

O N

S T

R U

C T

I O

N

J D

H

I S

S U

O N

S T

R U

C T

I O

N

J D

H

D A

T E

ISSUED FOR BID / CONSTRUCTION

CONCEPTUAL HEADWALL / ENDWALL PLAN VIEW

TURBIDITY CURTAIN DETAILS

NTS

NTS

TIDE GATE ELEVATION VIEW

NTS

SEE FABRICATION NOTE (DETAIL SHEET 14)

GATE SPECIFICATIONS:

1. THE WORK COVERED UNDER THIS SPECIFICATION SHALL CONSIST OF FURNISHING AND INSTALLING THE TIDE GATES IN THE QUANTITIES, SIZES AND LOCATION AS SET FORTH IN THE PLANS, SPECIFICATIONS AND BID DOCUMENTS.

2. TIDE GATES SHALL BE A MEDIUM DUTY AUTOMATIC DRAINAGE, THE CONTRACTOR SHALL SUBMIT TO THE PROJECT ENGINEER TECHNICAL

SPECIFICATIONS OF TIDE GATE 6 WEEKS PRIOR TO INSTALLATION.

3. THE FOLLOWING REQUIREMENTS ARE MINIMUM AND MUST BE MET BY THE TIDE GATE MANUFACTURER UNLESS OTHERWISE APPROVED IN WRITING BY THE

ENGINEER.

THE FRAME, COVER, AND HINGE LINK SHALL BE ALUMINUM ALLOY 6061 - T6, ALL SURFACES SHALL HAVE A MILL FINISH.

THE HINGE MECHANISM (BOLTS, WASHERS AND NUTS) SHALL BE TYPE 304 STAINLESS STEEL MEETING THE REQUIREMENTS OF ASTM F 593.

THE "SEAL" THAT INTERFACES THE RIM OF THE RING AND THE HEAD SHALL BE COMPOSED OF NEOPRENE RUBBER ASTM D 2000.

4. ALL WELDING SHALL BE MIG (METAL ARC INERT GAS) IN ACCORDANCE WITH THE REQUIREMENTS OF MILITARY AND FEDERAL SPECIFICATIONS MIL-W-45205.

THE TIDE GATE SHALL BE DESIGNED AND CONSTRUCTED TO WITHSTAND A MINIMUM SEATING HEAD OF THIRTY (30) FEET AND SHALL BE ADJUSTABLE (IN

BOTH THE VERTICAL AND HORIZONTAL DIRECTIONS) TO BE FREE FLOWING ON THE UNSEATING HEAD SIDE. THE TIDE GATE SHALL BE PACKAGED IN A

SECURE MANNER TO REDUCE MOVEMENT OR DAMAGE DURING NORMAL SHIPPING.

CONNECTION TO PRECAST CONCRETE ENDWALLS SHALL BE DESIGNED BY PRECAST FABRICATION ENGINEER AND SUBMITTED TO NRCS PROJECT

ENGINEER FOR APPROVAL. FABRICATION ENGINEER SHALL ALSO SUBMIT ANY AND ALL TIDE GATE DESIGN CALCULATIONS TO NRCS PROJECT ENGINEER

FOR APPROVAL. THIS INFORMATION SHALL BE INCLUDED IN THE SUBMITTAL AS OUTLINE ABOVE IN ITEM B.2.B.

TIDE GATE INSTALLATION INSTRUCTIONS FOR CORRUGATED HDPE-S PIPE:

1. CLEAN THE INSIDE TWELVE INCHES AT THE END OF THE PIPE THAT WILL RECEIVE THE TIDE GATE.

2. APPROXIMATELY THREE (3) INCHES FROM THE END, APPLY A DOUBLE BEAD OF SEALANT (SIKA-FLEX OR EQUAL) ALL AROUND THE INSIDE OF

THE HDPE PIPE.

3. SLIDE THE 12 INCH LONG 3/16 THICK SMOOTH ALUMINUM STUB, FLANGED TO MATCH TIDE GATE, COATED WITH MARINE ADHESIVE SEALANT INTO

THE HDPE PIPE.

4. INSTALL SIX (6) 5/8 INCH ALUMINUM BOLTS EVEN SPACED AROUND THE HDPE PIPE AND THROUGH THE ALUMINUM STUB. THE ALUMINUM BOLTS

WILL HAVE FLAT WASHER ON THE HEAD END AND A FLAT WASHER AND LOCKING NUT ON THE THREADED END. BOLTS SHALL BE INSTALLED

WITH THE BOLT HEAD ON THE INSIDE OF THE PIPE.

5. THE ABOVE INFORMATION IS ONLY SUGGESTED INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE

APPROPRIATE INSTALLATION SEQUENCE/NEEDS IN ORDER TO ENSURE A WATER TIGHT SEAL AND CORRECT FUNCTIONING OF THE TIDE GATE.

TYPICAL SLOPE PROTECTION DETAIL

NTS

LOCKING EYE DETAIL

(BOTH SIDES)

NTS

I S

S U

O N

S T

R U

C T

I O

N

J D

H

S A

O A r e a n g i n e e r i n g P

R O

J E

C T

S

O u t f a l l

F a r m s

C o n s t r u c t i o n

D r a w i n g s S h e e t s

U p d a t e d

D

T

S h e e t d w g

P

M

D

W G

T o

P

D F p c

File details come from the government source that posted it. Updated .