20160706_Outfall_Farms_REV_1_ISSUED_FOR_CONSTRUCTION_SHEETS_11_-_15.pdf

PDF 6 MB Posted

Attached to
Wetland Restoration Project - Hyde County, North Carolina - Easement 664532960048W
Solicitation number
AG-2B46-S-16-0011
Issued by

About this file

Drawings 11-15

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WEST SOUTH PATH 0+00.00-9+00.00

0+50

1+00

1+50

2+00

2+50

3+00

3+50

4+00

4+50

5+00

5+50

6+00

6+50

7+00

7+50

8+00

8+50

STA:6+89.97

ELEV:2.25

STA:0+69.34

ELEV:2.25

STA:6+06.88

ELEV:2.25

WEST SOUTH PATH 9+00.00-18+00.00

9+50

10+00

10+50

11+00

11+50

12+00

12+50

13+00

13+50

14+00

14+50

15+00

15+50

16+00

16+50

17+00

17+50

STA:10+48.15

ELEV:2.25

STA:11+10.35

ELEV:2.25

WEST SOUTH PATH 18+00.00-27+00.00

18+50

19+00

19+50

20+00

20+50

21+00

21+50

22+00

22+50

23+00

23+50

24+00

24+50

25+00

25+50

26+00

26+50

STA:20+29.62

ELEV:2.25

STA:20+82.43

ELEV:2.25

WEST SOUTH PATH 27+00.00-36+00.00

27+50

28+00

28+50

29+00

29+50

30+00

30+50

31+00

31+50

32+00

32+50

33+00

33+50

34+00

34+50

35+00

35+50

STA:30+18.54

ELEV:2.25

STA:30+81.48

ELEV:2.25

STA:31+82.71

ELEV:2.25

STA:33+88.04

ELEV:2.25

STA:34+65.67

ELEV:2.25

WEST SOUTH PATH 36+00.00-39+67.70

36+50

37+00

37+50

38+00

38+50

39+00

39+50

STA:36+88.73

ELEV:2.25

STA:39+31.56

ELEV:2.25

O U

T F

A L L

F

A R

M S

W E

S T

O U

H

P

A T

H W

A Y

BAR IS ONE INCH ON

ORIGINAL DRAWING

0 1"

DATE:

PROJ:

DWG:

VERIFY SCALE

9/14/2012

SCALE AS SHOWN

W E

T L A

N D

R

E S

E R

V

O

G R

A M

SHEET: of 15

D S

G N

D

R

C H

K

A P

V D

N o

D

E S

C R

I P

T I O

N A

P V

D B

Y D

A T

E

J D

H S

D L

T L

R J D

H

I S

S U

F

B

I

C

O N

S T

R U

C T

I O

N

J D

H

D A

T E

ISSUED FOR BID / CONSTRUCTION

HORIZONTAL SCALE: 1" = 40'

40200 80 120

V E

R T

I C

A L

S

C A

L E

2.0

4.0

8.0

12.0

EXISTING WEST SOUTH PATH

EXISTING SOUTHWEST PATH

PROPOSED GRADING

START STA: 0+69.34

END STA: 6+06.88

ELEV: 2.25

PROPOSED GRADING

START STA: 11+10.35

END STA: 20+29.62

ELEV: 2.25

PROPOSED GRADING

START STA: 20+82.43

END STA: 30+18.54

ELEV: 2.25

EXISTING SOUTH PATH

PROPOSED GRADING

START STA: 6+89.97

END STA: 10+48.15

ELEV: 2.25

PROPOSED GRADING

START STA: 30+81.48

END STA: 31+82.71

ELEV: 2.25

PROPOSED GRADING

START STA: 33+88.04

END STA: 34+65.67

ELEV: 2.25

PROPOSED GRADING

START STA: 36+88.73

END STA: 39+31.56

ELEV: 2.25

PROFILE VIEW

(1" = 40' HORIZ., 1" = 4.0' VERT.)

GENERAL NOTES

1. CONTRACTOR SHALL ADHERE TO ALL SEDIMENT AND EROSION CONTROL

PRACTICES AS SPECIFIED WITHIN THIS CONTRACT.

2. CONTRACTOR SHALL PROVIDE SMOOTH TRANSITIONS BETWEEN PROPOSED

AND EXISTING GRADE.

3. SHADED AREAS DEPICTED IN PLAN VIEWS ARE FOR GRAPHICAL

REPRESENTATION ONLY, SEE PROFILES AND TYPICAL CROSS SECTIONS FOR

DETAILED INFORMATION.

4. CONTRACTOR TO DISPOSE OF ALL SPOIL, WAIST AND DEBRIS PER

CONSTRUCTION PLANS AND SPECIFICATIONS

HORIZONTAL SCALE: 1" = 150'

150750 300 450

WEST SOUTH PATHWAY IMPROVEMENT TABLE

START STOP

APPROX.

LENGTH

TOP ELEV.

STA: 0+69.34 STA: 6+06.88 538 L.F. 2.25

STA: 6+89.97 STA: 10+48.15 358 L.F. 2.25

STA: 11+10.35 STA: 20+29.62 920 L.F. 2.25

STA: 20+82.43 STA: 30+18.54 936 L.F. 2.25

STA: 30+81.48 STA: 31+82.71 101 L.F. 2.25

STA: 33+88.04 STA: 34+65.67 78 L.F. 2.25

STA: 36+88.73 STA: 39+31.56 243 L.F. 2.25

PLAN VIEW

SCALE: 1" = 150'

SEE TYPICAL PATHWAY

CROSS SECTION (SHEET 7)

I S

S U

O N

S T

R U

C T

I O

N

J D

H

SOUTH PATH 0+00.00-9+00.00

0+50

1+00

1+50

2+00

2+50

3+00

3+50

4+00

4+50

5+00

5+50

6+00

6+50

7+00

7+50

8+00

8+50

STA:3+75.96

ELEV:2.25

STA:4+76.71

ELEV:2.25

STA:6+05.03

ELEV:2.25

L O

D

L O

D

L O

D

L O

D

LO

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L O

D

L

O

D

L O

D

L O

D

4+00

SOUTH PATH 9+00.00-18+00.00

9+50

10+00

10+50

11+00

11+50

12+00

12+50

13+00

13+50

14+00

14+50

15+00

15+50

16+00

16+50

17+00

17+50

STA:10+25.81

ELEV:2.25

STA:12+90.19

ELEV:2.25

STA:13+82.67

ELEV:2.25

STA:14+25.28

ELEV:2.25

SOUTH PATH 18+00.00-27+00.00

18+50

19+00

19+50

20+00

20+50

21+00

21+50

22+00

22+50

23+00

23+50

24+00

24+50

25+00

25+50

26+00

26+50

SOUTH PATH 27+00.00-36+00.00

27+50

28+00

28+50

29+00

29+50

30+00

30+50

31+00

31+50

32+00

32+50

33+00

33+50

34+00

34+50

35+00

35+50

STA:30+76.42

ELEV:2.25

O U

T F

A L L

F

A R

M S

S O

U T

H

P

A T

H W

A Y

BAR IS ONE INCH ON

ORIGINAL DRAWING

0 1"

DATE:

PROJ:

DWG:

VERIFY SCALE

9/14/2012

SCALE AS SHOWN

W E

T L A

S

E R

O

G R

A M

SHEET: of 15

D S

G N

D

R

C H

K

A P

V D

N o

D

E S

C R

I P

T I O

N A

P V

D B

Y D

A T

E

J D

H S

D L

T L

R J D

H

I S

S U

O N

S T

R U

C T

I O

N

J D

H

D A

T E

ISSUED FOR BID / CONSTRUCTION

HORIZONTAL SCALE: 1" = 40'

40200 80 120

V E

R T

I C

A L

S

C A

L E

2.0

4.0

8.0

12.0

EXISTING WEST SOUTH PATH

EXISTING SOUTH PATH

PROPOSED GRADING

START STA: 3+75.96

END STA: 4+76.71

ELEV: 2.25

PROPOSED GRADING

START STA: 6+05.03

END STA: 10+25.81

ELEV: 2.25

PROPOSED GRADING

START STA: 12+90.19

END STA: 13+82.67

ELEV: 2.25

PROPOSED GRADING

START STA: 14+25.28

END STA: 30+76.42

ELEV: 2.25

PROFILE VIEW

(1" = 40' HORIZ., 1" = 4.0' VERT.)

GENERAL NOTES

1. CONTRACTOR SHALL ADHERE TO ALL SEDIMENT AND EROSION CONTROL

PRACTICES AS SPECIFIED WITHIN THIS CONTRACT.

2. CONTRACTOR SHALL PROVIDE SMOOTH TRANSITIONS BETWEEN PROPOSED

AND EXISTING GRADE.

3. SHADED AREAS DEPICTED IN PLAN VIEWS ARE FOR GRAPHICAL

REPRESENTATION ONLY, SEE PROFILES AND TYPICAL CROSS SECTIONS FOR

DETAILED INFORMATION.

4. CONTRACTOR TO DISPOSE OF ALL SPOIL, WAIST AND DEBRIS PER

CONSTRUCTION PLANS AND SPECIFICATIONS

HORIZONTAL SCALE: 1" = 150'

150750 300 450

SOUTH PATHWAY IMPROVEMENT TABLE

START STOP

APPROX.

LENGTH

TOP ELEV.

STA: 3+75.96 STA: 4+76.71 101 L.F. 2.25

STA: 6+05.03 STA: 10+25.81 421 L.F. 2.25

STA: 12+90.19 STA: 13+82.67 93 L.F. 2.25

STA: 14+25.28 STA: 30+76.42 1651 L.F. 2.25

S H

E E

T

S H

E E

T

PLAN VIEW

SCALE: 1" = 150'

SEE TYPICAL PATHWAY

CROSS SECTION (SHEET 7)

I S

S U

O N

S T

R U

C T

I O

N

J D

H

SOUTH PATH 36+00.00-45+00.00

SOUTH PATH 45+00.00-54+00.00

SOUTH PATH 54+00.00-63+00.00

36+50

37+00

37+50

38+00

38+50

39+00

39+50

40+00

40+50

41+00

41+50

42+00

42+50

43+00

43+50

44+00

44+50

45+50

46+00

46+50

47+00

47+50

48+00

48+50

49+00

49+50

50+00

50+50

51+00

51+50

52+00

52+50

53+00

53+50

54+50

55+00

55+50

56+00

56+50

57+00

57+50

58+00

58+50

59+00

59+50

60+00

60+50

61+00

61+50

62+00

62+50

STA:60+22.64

ELEV:2.25

STA:60+66.41

ELEV:2.25

67+14

O U

T F

A L L

F

A R

M S

S O

U T

H

P

A T

H W

A Y

BAR IS ONE INCH ON

ORIGINAL DRAWING

0 1"

DATE:

PROJ:

DWG:

VERIFY SCALE

9/14/2012

SCALE AS SHOWN

W E

T L A

S

E R

O

G R

A M

SHEET: of 15

D S

G N

D

R

C H

K

A P

V D

N o

D

E S

C R

I P

T I O

N A

P V

D B

Y D

A T

E

J D

H S

D L

T L

R J D

H

I S

S U

O N

S T

R U

C T

I O

N

J D

H

D A

T E

ISSUED FOR BID / CONSTRUCTION

HORIZONTAL SCALE: 1" = 40'

40200 80 120

V E

R T

I C

A L

S

C A

L E

2.0

4.0

8.0

12.0

PROFILE VIEW

(1" = 40' HORIZ., 1" = 4.0' VERT.)

GENERAL NOTES

1. CONTRACTOR SHALL ADHERE TO ALL SEDIMENT AND EROSION CONTROL

PRACTICES AS SPECIFIED WITHIN THIS CONTRACT.

2. CONTRACTOR SHALL PROVIDE SMOOTH TRANSITIONS BETWEEN PROPOSED

AND EXISTING GRADE.

3. SHADED AREAS DEPICTED IN PLAN VIEWS ARE FOR GRAPHICAL

REPRESENTATION ONLY, SEE PROFILES AND TYPICAL CROSS SECTIONS FOR

DETAILED INFORMATION.

4. CONTRACTOR TO DISPOSE OF ALL SPOIL, WAIST AND DEBRIS PER

CONSTRUCTION PLANS AND SPECIFICATIONS

EXISTING SOUTH PATH

EXISTING EAST PATH

PROPOSED GRADING

START STA: 60+22.64

END STA: 60+66.41

ELEV: 2.25

PROPOSED

WATER CONTROL

STRUCTURE C

(SEE SHEET 5)

PROPOSED

WATER CONTROL

STRUCTURE D

(SEE SHEET 5)

PLAN VIEW

SCALE: 1" = 150'

HORIZONTAL SCALE: 1" = 150'

150750 300 450

SOUTH PATHWAY IMPROVEMENT TABLE

START STOP

APPROX.

LENGTH

TOP ELEV.

STA: 60+22.64 STA: 60+66.41 44 L.F. 2.25

S H

E E

T

S H

E E

T

EXISTING PATH

SEE TYPICAL PATHWAY

CROSS SECTION (SHEET 7)

I S

S U

O N

S T

R U

C T

I O

N

J D

H

LEGEND OF TABLE

EL. "A" = TOP OF FILL OVER STRUCTURE

EL. "B" = TOP OF RISER

EL. "C" = BOTTOM OF CONCRETE

EL. "D" = UPPER INVERT OF PIPE

EL. "E" = LOWER INVERT OF PIPE

EL. "F" = PERMANENT WEIR

L = LENGTH OF PIPE

FLOW

EL. "D" = INLET

CONCRETE FLASH

BOARD RISER

TOP OF RISER EL. "B"

1-1/2" HOLE FOR

LOCKING ROD

"L"= LENGTH OF PIPE

CONCRETE BASE EL. "C"

TOP OF FILL EL. "A" = CONSTRUCTED

VAR.

VARIABLE MIN. 5:1

COMPACTED BACK FILL TO

TIE TO SUITABLE MINERAL

SOILS (DEPTH VARIES). PER

FABRICATION ENGINEER.

2.0' MIN., #57 STONE

FOUNDATION PER

FABRICATION ENGINEER

GEOTEXTILE

EL."E" = OUTLET

WRAP NON-WOVEN GEOTEXTILE AROUND

PIPE AT ALL PIPE JOINTS.

(MIN. 1.0' OVERLAP BOTH SIDES)

REAR WALL OF RISER SHALL BE

FLUSH WITH FINISH GRADE SLOPE

2 LF (MIN.)

EL. "F" = WEIR

2"

6" MIN.

TYPICAL SECTION OF WATER CONTROL STRUCTURE

NTS.

RIP-RAP SCOUR PROTECTION WIDTH 2X

PIPE DIAMETER BY 2X PIPE DIAMETER,

DEPTH OF ROCK 12" (INCHES). CLASS A

RIP-RAP PER SPECIFICATIONS. UNDERLAY

WITH CLASS 1 NON-WOVEN GEO-TEXTILE

MATERIAL RIP-RAP SHALL NOT IMPEDE

TIDE GATE FUNCTION.

CLASS 1 NON-WOVEN GEO-TEXTILE

2' MIN.

SEE STRUCTURE TABLE FOR

HEADWALL, ENDWALL AND TIDE GATE

REQUIREMENTS FOR EACH STRUCTURE

SCOUR PROTECTION

WIDTH = 2 x PIPE DIA.

LENGTH = 2 x PIPE DIA.

DEPTH = 12 INCHES

RIP-RAP SLOPE PROTECTION

(TYP.)

EQUILATERAL

ORIENTED

POLYPROPYLENE

GEOGRID

RIP-RAP SLOPE PROTECTION

SHALL BE INSTALLED TO THE

TOP OF THE WATER CONTROL

STRUCTURE (TYP. ) BOTH SIDES

PIPE-TO-MANHOLE-CONNECTOR BOOT

PER FABRICATION ENGINEER

AND GROUTED IN PLACE PER

SPECIFICATIONS. (BOTH SIDES)

ALUMINUM FLASHBOARDS

10 Ga. ALUMINUM GUIDE

2" x 2" CHANNEL

BUTYL-SEALANT GASKET (TYP.)

TOP

HEADWALLS

PIPE-TO-MANHOLE-CONNECTOR

BOOT PER FABRICATION ENGINEER

AND GROUTED IN PLACE

(BOTH SIDES)

CENTER SUPPORT MIN. 8" X 12"

U CHANNEL SHALL BE TABBED

AND TIED TO RE-BAR ON

VERTICAL SUPPORTS. RE-BAR

SHALL RUN THROUGH THE

ENTIRETY OF THE CENTER

SUPPORT

LOCKING ROD PLAN VIEW

NTS.

FLATTEN END AND DRILL

2" HOLE.

3/4" ALUMINUM ROD

LENGTH VARIES

TO FIT STRUCTURE.

TWO LIFTING HOOKS PER

STRUCTURE. LENGTH OF LIFTING

HOOKS ADEQUATE TO REACH

BOTTOM STOPLOG.

1' - 6"

3"

V A

R I E

S

1/2'"

ROUND

BAR

STOPLOG LIFTING HOOK

NTS.

2"

8"

1/2" ROUND BAR WELDED

TO TUBULAR ALUM. AS

SHOWN (2 REQ'D PER

STOPLOG).

NOTE: CONTRACTOR SHALL FURNISH,

FABRICATE, AND INSTALL STOPLOGS TO

BE FABRICATED FROM

" TUBULAR

ALUMINUM. LENGTH OF STOPLOGS

SHALL BE 1/2" LESS THAN DISTANCE

BETWEEN CHANNELS.

2"

ALUMINUM STOPLOG

NTS.

ORTHOGRAPHIC VIEW

10 Ga. ALUMINUM

GUIDE 2" x 2" CHANNEL

BUTYL-SEALANT

GASKET (TYP.)

LOCKING EYE

STRUCTURAL

CONCRETE

PIPE-TO-MANHOLE

CONNECTOR

BOOT

CONCRETE CENTER

SUPPORT ONLY FOR

STRUCTURES WIDER

THAN 5 FOOT

TOP OF FILL

EXISTING GRADE

O.D. 1/2 O.D.1/2 O.D.

GENERAL NOTES:

OD. = THE MAXIMUM HORIZONTAL OUTSIDE DIMENSION

DO NOT OPERATE HEAVEY EQIPMENT OVER ANY STRUCTURAL PLATE PIPE UNTIL THE STRUCTURAL PLATE PIPE HAS

BEEN PROPERLY BACKFILLED AND COVERED WITH AT LEAST 2.0 FEET OF APPROVED MATERIAL.

* O.D. / 12 NOT LESS THAN 6" MIN.

APPROVED SUITABLE LOCAL MATERIAL OR SELECT MATERIAL FOR

FOUNDATION CONDITIONING AS DIRECTED BY ENGINEER

APPROVED BACKFILL OR SELECT MATERIAL

UNDISTURBED EARTH MATERIAL

EARTH BACKFILL ADJACENT TO STRUCTURES SHALL BE COMPACTED TO A DENSITY EQUIVALENT TO THAT OF THE

SURROUNDING INPLACE EARTH MATERIAL OR ADJACENT REQUIRED EARTHFILL OR EARTH BACKFILL. COMPACTION

SHALL BE ACCOMPLISHED BY HAND TAMPING OR MANUALLY DIRECTED POWER TAMPERS, PLATE VIBRATORS, WALK-BEHIND, MINIATURE, OR SELF-PROPELLED ROLLERS. UNLESS OTHERWISE SPECIFIED HEAVY EQUIPMENT

INCLUDING BACKHOE MOUNTED POWER TAMPERS OR VIBRATING COMPACTORS AND MANUALLY DIRECTED

VIBRATING ROLLERS SHALL NOT BE OPERATED WITHIN 3 FEET OF ANY STRUCTURE. TOWED OR SELF-PROPELLED

VIBRATING ROLLERS SHALL NOT BE OPERATED WITHIN 5 FEET OF ANY STRUCTURE. COMPACTION BY MEANS OF

DROP WEIGHTS OPERATING FROM A CRANE OR HOIST IS NOT PERMITTED.

PIPE INSTALLATION

NTS.

TOP OF FILL

EXISTING GRADE

AS DIRECTED

BY ENGINEER

O.D. 1/2 O.D.1/2 O.D.

SEE EARTH BACKFILL NOTE

BELOW FOR HAND

COMPACTED FILL

SINGLE PIPE

DUAL PIPE

O.D.

3.0' MIN.

SEE EARTH BACKFILL NOTE

BELOW FOR HAND

COMPACTED FILL

AS DIRECTED BY ENGINEER

HDPE TYPE S PIPE

AASHTO M 294

1/4" ALUMINUM STEEL PLATES

W/ 1-1/2" HOLE FOR

LOCKING ROD (TYP.)

INTERNAL STEEL AND LIFTING

HOOKS SHALL BE DESIGNED

BY A NORTH CAROLINA

REGISTERED PROFESSIONAL

ENGINEER

FRONT RIGHT

2"

CONCRETE FLASHBOARD RISER DETAIL

NTS.

STRUCTURE PIPE

STRUCTURE

WEIR TOP OF FILL TOP OF RISER

BASE

ELEVATION

INVERT

ELEVATION

FIXED WEIR

ELEVATION

NO. OF 4 IN.

BOARDS

NO. OF 6 IN.

BOARDS

PIPE INVERT IN INVERT OUT LENGTH

HEAD

WALL

END WALL TIDE GATE

NORTHING EASTING WEIR LENGTH EL. "A" EL. "B" EL. "C" EL. "D" EL. "F" SIZE QUANTITY MATERIAL EL. "D" NORTHING EASTING EL. "E" NORTHING EASTING LF

WCS A-1 625229.66 2845080.79 18.0' 4.00 1.65 -2.85 -2.35 -0.5 4 6 42" 1 HDPE - S -2.35 625227.23 2845076.71 -2.35 625193.14 2845019.61 66 YES YES YES

WCS A-2 625224.51 2845083.87 18.0' 4.00 1.65 -2.85 -2.35 -0.5 4 6 42" 1 HDPE - S -2.35 625222.07 2845079.79 -2.35 625187.87 2845022.77 66 YES YES YES

WCS B 624418.59 2845586.03 18.0' 4.00 1.65 -2.85 -2.35 -0.5 4 6 42" 1 HDPE - S -2.35 624416.01 2845581.75 -2.35 624393.06 2845543.62 45 YES YES YES

WCS C 619081.85 2858086.52 18.0' 3.15 1.65 -2.85 -2.35 -0.5 4 6 42" 1 HDPE - S -2.35 619077.11 2858086.70 -2.35 619041.13 2858088.07 30 YES YES YES

WCS D-1 619440.46 2860251.97 18.0' 3.15 1.65 -2.85 -2.35 -0.5 4 6 42" 1 HDPE - S -2.35 619438.18 2860255.85 -2.35 619401.76 2860317.96 72 YES YES YES

WCS D-2 619435.47 2860249.08 18.0' 3.15 1.65 -2.85 -2.35 -0.5 4 6 42" 1 HDPE - S -2.35 619433.01 2860252.81 -2.35 619396.56 2860314.90 72 YES YES YES

WCS E 622675.12 2854509.97 18.0' 3.15 1.65 -2.85 -2.35 -0.5 4 6 42" 1 HDPE - S -2.35 622672.67 2854514.05 -2.35 622652.43 2854547.78 33 YES YES NO

DUAL CUT AWAY

NOTE:

IMAGES FOR REFERENCE ONLY.

FABRICATION ENGINEER TO DESIGN

REBAR BENT 90° 9" O.C.,

ADJACENT REBAR TO BE SET IN

THE OPPOSITE DIRECTION

DUAL

SPACE BETWEEN STRUCTURES

SHALL HAVE A SEPARATION

DISTANCE OF 2 TIMES THE

ADJOINING WALL LENGTH.

BAR IS ONE INCH ON

ORIGINAL DRAWING

0 1"

DATE:

PROJ:

DWG:

VERIFY SCALE

SCALE AS SHOWN

W E

T L

A N

D

R

E S

E R

O

G R

A M

O U

T F

A L

L

F

A R

M S

D E

T A

I L

S

SHEET: of 15

9/14/2012

D S

G N

D

R

C H

K

A P

V D

N o

D

E S

C R

I P

T I O

N A

P V

D B

Y D

A T

E

J D

H S

D L

T L

R J D

H

I S

S U

O N

S T

R U

C T

I O

N

J D

H

D A

T E

ISSUED FOR BID / CONSTRUCTION

FABRICATION NOTES:

1. THE PLANS FOR PRECAST UNITS SHALL BE DRAWINGS AND CALCULATION SHEETS

FURNISHED BY THE CONTRACTOR FOR APPROVAL BY THE ENGINEER. THESE DRAWINGS

AND CALCULATIONS SHALL SHOW COMPLETE DESIGN, INSTALLATION, STRUCTURAL

LOADING, FOUNDATION, AND CONSTRUCTION INFORMATION IN SUCH DETAIL AS TO

ENABLE THE ENGINEER TO DETERMINE THE ADEQUACY OF THE PROPOSED UNITS FOR

THE INTENDED PURPOSE. DETAILS OF THE STEEL REINFORCEMENT SIZE AND PLACEMENT

SHALL BE INCLUDED. THE DRAWINGS SHALL ALSO INCLUDE A SCHEDULE WHICH WILL LIST

THE SIZE AND TYPE OF PRECAST UNIT AT EACH LOCATION WHERE THE UNITS ARE TO BE

USED. DRAWINGS SHALL BE CERTIFIED BY A NORTH CAROLINA REGISTERED

PROFESSIONAL ENGINEER. THESE DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER

SIX (6) WEEKS PRIOR TO THE PRECAST UNITS BEING INSTALLED FOR APPROVAL. THE

PRECAST UNITS SHALL BE PRODUCED IN ACCORDANCE WITH THE APPROVED DRAWINGS.

2. IT IS THE CONTRACTORS RESPONSIBILITY TO FIELD FIT AND VERIFY ALL COMPONENTS TO

INSURE PROPER FIT AND SIZE. ANY COMPONENT THAT DOES NOT CONFORM TO THE SHOP

DRAWINGS OR THAT DOES NOT FIT PROPERLY WILL NEED TO BE RE-MANUFACTURED AT

THE CONTRACTORS OWN EXPENSE.

3. TOLERANCE SHALL BE ± 1/4" FROM APPROVED SHOP DRAWINGS.

4. THE FABRICATION ENGINEER IS TO CERTIFY THAT UNITS ARE BUILT IN ACCORDANCE WITH

SHOP DRAWINGS. FABRICATION ENGINEER, REGISTERED PROFESSIONAL ENGINEER IN

THE STATE OF NORTH CAROLINA, SHALL SEND A SEALED CERTIFICATION LETTER TO NRCS

UPON PRODUCT DELIVERY ONSITE THAT PRECAST UNITS MEET OR EXCEED THE

APPROVED SHOP DRAWINGS.

*ASSUMES A 0.5 FT THICK PRECAST BASE, SHOULD FABRICATION ENGINEER DESIGN A DIFFERENT THICKNESS ELEVATIONS WOULD NEED TO BE ADJUSTED.

1. CONTRACTOR SHALL USE CAST IN PLACE TO FILL VOIDS BETWEEN STRUCTURES.

DOWEL BETWEEN STRUCTURES WITH REBAR FROM PRE-CAST MANUFACTURER.

2. CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNED BY FABRICATION ENGINEER TO

PROJECT ENGINEER.

3. CONCRETE USED TO TIE STRUCTURES TOGETHER SHALL BE 6000 p.s.i. CONCRETE.

4. CONCRETE SHALL BE VIBRATED TO REMOVE AIR VOIDS.

5. CONCRETE FORMS SHALL REMAIN IN PLACE FOR A MINIMUM OF 3 DAYS.

STRUCTURE CONNECTION NOTES:

I S

S U

O N

S T

R U

C T

I O

N

J D

H

PONDING HEIGHT

FLOW

F

L

O

W

24" MIN.

STEEL

TRENCH DETAIL

FILTER FABRIC SHALL BE IN ACCORDANCE

WITH CONSTRUCTION SPECIFICATIONS

STEEL POST

5 FT. POST LENGTH (MIN.), 1.25 LBS./FT. WEIGHT

(MIN.) 1-3/8 INCHES WIDE (MIN.), 14 SQUARE

INCHES ANCHOR PLATE SURFACE AREA (MIN.)

MAX. SEDIMENT LEVEL 0.25 FT.

36" MIN.

ATTACH FABRIC TO POSTS IN

ACCORDANCE WITH CONSTRUCTION

SPECIFICATIONS

NOTE:

1. SILT FENCE SHALL BE PLACED ON SLOPE CONTOURS TO MAXIMIZE PONDING EFFICIENCY.

2. INSPECT AND REPAIR FENCE AFTER EACH STORM EVENT AND REMOVE SEDIMENT WHEN

NECESSARY. 0.5 FT. MAXIMUM RECOMMENDED STORAGE HEIGHT.

3. REMOVED SEDIMENT SHALL BE DEPOSITED IN SPOIL AREA AS SHOWN ON CONSTRUCTION

DRAWINGS.

4"X8" TRENCH WITH

COMPACTED BACKFILL

8' MAXIMUM SPACING WITH WIRE

SUPPORT FENCE; 6' MAXIMUM SPACING

WITHOUT WIRE SUPPORT FENCE

ATTACH FILTER FABRIC

SECURELY TO UPSTREAM

SIDE OF POST

" H.G.

BALLAST CHAIN

FOR WEIGHT

FLOTATION

CHAIN TENSIONED THROUGH

S.S. STRESS PLATES, VIA

HOOK AND RING CONNECTION

ANCHOR POINTS

CURTAIN MEMBRANE

ANCHOR POINTS

" GAL

CABLE

CHANNEL BOTTOM

FLOW DIRECTION

CHANNEL BANK

CHANNEL BANK

TURBIDITY CURTAIN

EXTENDS TO BOTTOM

OF CHANNEL

ANCHOR POINTS

ANCHOR POINTS

SECTION VIEW

PLAN VIEW

NOTE: INSTALL AND MAINTAIN TURBIDITY CURTAIN IN ACCORDANCE WITH MANUFACTURE'S

SPECIFICATIONS. CONTRACTOR SHALL SUBMIT TO ENGINEER THE PRODUCT CUT SHEET,

INSTALLATION SPECIFICATIONS, AS WELL AS A MAINTENANCE PLAN/SCHEDULE FOR REVIEW

AND CONCURRENCE. ANCHORING STRUCTURES SHALL BE CONSTRUCTED AND/OR

INSTALLED PER MANUFACTURE'S RECOMMENDATIONS FOR PROPER LATERAL FORCE

REQUIREMENTS.

MIN. 20.0' BERM

1 1

VARIES

MIN. 20.0' BERM

M

A X

DESIGNED BORROW AREA

VARIES

LIMITS OF DISTURBANCE PER PLANS AND SPECIFICATIONS

V A

R I E

S

DEBRIS AND SPOIL AREA

TYPICAL BORROW AREA CROSS-SECTION

M

A X

VARIES

DEBRIS AND SPOIL AREA

(NTS.)

MAX. DEPTH 4.0 FEET AFTER

CLOSING THE BORROW AREA

C

LIFTING HOLE

REF.

B DIA.

O.D.

BOLT DIA. = M

PROJECTION = P

BOLT CIRCLE = BC.

22 1/2 °

22 1/2 °

22 1/2 °

22 1/2 °

A DIA.

D2

No. NAME

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

FRAME

SEAT

RETAINER RING

HEX HEAD BOLT / NUT

COVER

HINGE ARM

PIVOT LUG

HINGE PIN

BUSHING

WASHER

SPRING PIN

HEX HEAD BOLT / NUT

6" CONCRETE HEADWALL

DESIGNED BY FABRICATION

ENGINEER

DEADMAN

(TYP.)

PROPOSED 5' X 4' WATER CONTROL STRUCTURE

PROPOSED 57 STONE SUBGRADE

PROPOSED TIDEGATE

CONNECTING CABLE

(TYP.)

HEADWALL FOOTING BELOW

(TYP.)

PROPOSED PIPE

TOE OF SLOPE

AREA OF SLOPE PROTECTION CLASS A RIP-RAP

SHALL BE PLACED 5 FOOT PAST THE TOE OF SLOPE

TO THE TOP OF THE RISER. ELEVATION DEPTH

OF STONE SHALL BE 18 INCHES. STONE SHALL BE

UNDER LAID WITH NON-WOVEN GEO-TEXTILE.

TOP OF STRUCTURE ELEVATION

TYPICAL SLOPE PROTECTION FOR

BOTH HEADWALL / ENDWALL

TOE OF SLOPE

NON-WOVEN

GEO-TEXTILE

TOP OF STRUCTURE

ELEVATION

TOE OF SLOPE

NON-WOVEN

GEO-TEXTILE

TOP OF STRUCTURE

ELEVATION

2:1 MAX. SIDE SLOPE

2:1 MAX. SIDE SLOPE

PROPOSED HEADWALL / ENDWALL

PROPOSED STRUCTURE

PROPOSED STRUCTURE

PROPOSED HEADWALL / ENDWALL

NTS

SILT FENCE

BAR IS ONE INCH ON

ORIGINAL DRAWING

0 1"

DATE:

PROJ:

DWG:

VERIFY SCALE

SCALE AS SHOWN

W E

T L

A N

D

R

E S

E R

O

G R

A M

O U

T F

A L

L

F

A R

M S

D E

T A

I L

S

A

Y P

I C

A L

C

T I O

N

SHEET: of 15

9/14/2012

D S

G N

D

R

C H

K

A P

V D

N o

D

E S

C R

I P

T I O

N A

P V

D B

Y D

A T

E

J D

H S

D L

T L

R J D

H

I S

S U

O N

S T

R U

C T

I O

N

J D

H

D A

T E

ISSUED FOR BID / CONSTRUCTION

CONCEPTUAL HEADWALL / ENDWALL PLAN VIEW

TURBIDITY CURTAIN DETAILS

NTS

NTS

TIDE GATE ELEVATION VIEW

NTS

SEE FABRICATION NOTE (DETAIL SHEET 14)

GATE SPECIFICATIONS:

1. THE WORK COVERED UNDER THIS SPECIFICATION SHALL CONSIST OF FURNISHING AND INSTALLING THE TIDE GATES IN THE QUANTITIES, SIZES AND LOCATION AS SET FORTH IN THE PLANS, SPECIFICATIONS AND BID DOCUMENTS.

2. TIDE GATES SHALL BE A MEDIUM DUTY AUTOMATIC DRAINAGE, THE CONTRACTOR SHALL SUBMIT TO THE PROJECT ENGINEER TECHNICAL

SPECIFICATIONS OF TIDE GATE 6 WEEKS PRIOR TO INSTALLATION.

3. THE FOLLOWING REQUIREMENTS ARE MINIMUM AND MUST BE MET BY THE TIDE GATE MANUFACTURER UNLESS OTHERWISE APPROVED IN WRITING BY THE

ENGINEER.

THE FRAME, COVER, AND HINGE LINK SHALL BE ALUMINUM ALLOY 6061 - T6, ALL SURFACES SHALL HAVE A MILL FINISH.

THE HINGE MECHANISM (BOLTS, WASHERS AND NUTS) SHALL BE TYPE 304 STAINLESS STEEL MEETING THE REQUIREMENTS OF ASTM F 593.

THE "SEAL" THAT INTERFACES THE RIM OF THE RING AND THE HEAD SHALL BE COMPOSED OF NEOPRENE RUBBER ASTM D 2000.

4. ALL WELDING SHALL BE MIG (METAL ARC INERT GAS) IN ACCORDANCE WITH THE REQUIREMENTS OF MILITARY AND FEDERAL SPECIFICATIONS MIL-W-45205.

THE TIDE GATE SHALL BE DESIGNED AND CONSTRUCTED TO WITHSTAND A MINIMUM SEATING HEAD OF THIRTY (30) FEET AND SHALL BE ADJUSTABLE (IN

BOTH THE VERTICAL AND HORIZONTAL DIRECTIONS) TO BE FREE FLOWING ON THE UNSEATING HEAD SIDE. THE TIDE GATE SHALL BE PACKAGED IN A

SECURE MANNER TO REDUCE MOVEMENT OR DAMAGE DURING NORMAL SHIPPING.

CONNECTION TO PRECAST CONCRETE ENDWALLS SHALL BE DESIGNED BY PRECAST FABRICATION ENGINEER AND SUBMITTED TO NRCS PROJECT

ENGINEER FOR APPROVAL. FABRICATION ENGINEER SHALL ALSO SUBMIT ANY AND ALL TIDE GATE DESIGN CALCULATIONS TO NRCS PROJECT ENGINEER

FOR APPROVAL. THIS INFORMATION SHALL BE INCLUDED IN THE SUBMITTAL AS OUTLINE ABOVE IN ITEM B.2.B.

TIDE GATE INSTALLATION INSTRUCTIONS FOR CORRUGATED HDPE-S PIPE:

1. CLEAN THE INSIDE TWELVE INCHES AT THE END OF THE PIPE THAT WILL RECEIVE THE TIDE GATE.

2. APPROXIMATELY THREE (3) INCHES FROM THE END, APPLY A DOUBLE BEAD OF SEALANT (SIKA-FLEX OR EQUAL) ALL AROUND THE INSIDE OF

THE HDPE PIPE.

3. SLIDE THE 12 INCH LONG 3/16 THICK SMOOTH ALUMINUM STUB, FLANGED TO MATCH TIDE GATE, COATED WITH MARINE ADHESIVE SEALANT INTO

THE HDPE PIPE.

4. INSTALL SIX (6) 5/8 INCH ALUMINUM BOLTS EVEN SPACED AROUND THE HDPE PIPE AND THROUGH THE ALUMINUM STUB. THE ALUMINUM BOLTS

WILL HAVE FLAT WASHER ON THE HEAD END AND A FLAT WASHER AND LOCKING NUT ON THE THREADED END. BOLTS SHALL BE INSTALLED

WITH THE BOLT HEAD ON THE INSIDE OF THE PIPE.

5. THE ABOVE INFORMATION IS ONLY SUGGESTED INSTALLATION INSTRUCTIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE

APPROPRIATE INSTALLATION SEQUENCE/NEEDS IN ORDER TO ENSURE A WATER TIGHT SEAL AND CORRECT FUNCTIONING OF THE TIDE GATE.

TYPICAL SLOPE PROTECTION DETAIL

NTS

LOCKING EYE DETAIL

(BOTH SIDES)

NTS

I S

S U

O N

S T

R U

C T

I O

N

J D

H

File details come from the government source that posted it. Updated .