9_Arch2_A1.2-D7.0.pdf

PDF 6 MB Posted

Attached to
Building 26, Phase 3 Basement Renovation Federal contract opportunity
Solicitation number
AG-0343-S-16-0021
Issued by
Department of Agriculture Forest Service R1-Northern Region

About this file

Drawings - Arch 2

View the file

Other files for this federal contract opportunity

Other files attached to Building 26, Phase 3 Basement Renovation, newest first.
File Type Posted
S160021FinalAmendment0006QAs.pdf PDF
S160021FinalAmendment0005QAs.pdf PDF
S160021FinalAmendment0004QAs.pdf PDF
S160021FinalAmendment0003QAs.pdf PDF
S160021FinalAmendmen0002QAs.pdf PDF
Mechanical_Sketches.pdf PDF
20160607RevisedScheduleB.pdf PDF
20160607Sign-InSheetSiteVisitBuilding26Phase3.pdf PDF
13104_2_ASK_01_A1_2.pdf PDF
13104_2_ASK_03_A3_3.pdf PDF
13104_2_PSK_01-03.pdf PDF
13104_2_ASK_02_D2_0.pdf PDF
S160021FinalAmendmen0001QAs.pdf PDF
10_Arch3_D9.1.pdf PDF
15_13104.3_STRUCT.pdf PDF
Volume1_combined.pdf PDF
13_Arch6_A5.1-A9.2.pdf PDF
17_13104.3_PLUMB.pdf PDF
4_CIVIL3_C2.1-C3.1.pdf PDF
16_13104.3_MECH.pdf PDF
DOLBuildingWageRatesMslaCoMT64.pdf PDF
14_Arch7_A9.3-SP2.0.pdf PDF
3_CIVIL2_CD2.1.pdf PDF
1_Cover.pdf PDF
Volume2_combined.pdf PDF
11_Arch4_A2.0-A4.2.pdf PDF
20_Security_-_Phase_3_-_Basement.pdf PDF
19_13104.3_ELECT.pdf PDF
7_CIVIL6_C9.4.pdf PDF
20160518FinalAG0343S160021Build26Phase3.pdf PDF
12_Arch5_A4.3.pdf PDF
18_13104.3_FIRE.pdf PDF
2_CIVIL1_C1.1.pdf PDF
5_CIVIL4_C9.1.pdf PDF
6_CIVIL5_C9.2-C9.3.pdf PDF
8_Arch1_A1.1.pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

003.1

002.1

RB EXT LCP

M D

M

PNL M1A PNL M2A

MDR

MDP

001.1

001.3

004.1

008.1 FACP

005.1

006.1

007.1 009.1

013.1

011.1

014.1

016.1

023.1022.1021.1

010.2

024.1

027.1026.1025.1

030.1

029.1

033.1

034.1

034.2

031.1

010.1

028.1

015.1

035.1

001.2

036.1

035.2

017.1

017.2 020.2

020.1

DOWN

A1.2BUILDING 26 - PHASE 3, AREA OF WORK

A1.2 : A1.2 1/32" = 1'-0"

NORTH

FIRST FLOOR PLANBASEMENT FLOOR PLAN

SECOND FLOOR PLAN ATTIC FLOOR PLAN

1/32" = 1'-0"

BUILDING 26 - SITE PLAN

A1.2 : A1.2

= ASTERISK INDICATES CONTRACTOR ONLY ACCESS TO BASEMENT.

HATCH INDICATES AREA OF WORK.

NOTE: WORK INCLUDES ITEMS OUTSIDE AREAS INDICATED ABOVE; COORDINATE W/ STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION AS NECESSARY TO COMPLETE SCOPE OF WORK INDICATED.

FIRE GARAGE

BUILDING 26

(E)

LAWN &

TREES,

PROTECT

(E) LAWN AND

TREES, PROTECT.

(E) PARKING AREA

F ROAD

H ROAD

G R

O A

D P

O S

T S

I D

I N

G R

O A

D

F O

R T M

IS

S O

U L A

R O

A D

F R O

AD

(E) SIDEWALK TO REMAIN, PROTECT, TYP.

(E) TREES TO REMAIN,

PROTECT, TYP.

(E) TREES TO REMAIN,

PROTECT, TYP.

(E ) S

ID

E W

A L K , P

R O

T E C T , T

Y P

NORTH

OFFICERS

QUARTERS

WALL TYPE LEGEND

5/8" 'TYPE-X' GYPSUM WALL BOARD O/

2x6" WOOD FRAMING STUDS AT 2'-0" ON CENTER, SOUND ATTENUATION BATTS AT CAVITY O/

5/8" 'TYPE-X' GYPSUM WALL BOARD

5/8" GYPSUM WALL BOARD, INTERIOR-SIDE ONLY O/

2x4" WOOD FRAMING STUDS AT 2'-0" ON CENTER

(TURNED SIDEWAYS, PARALLEL TO EXTERIOR WALL) W/

2" RIGID THERMAL INSULATION, FILL CAVITY, O/

EXISTING EXTERIOR WALL CONSTRUCTION

3 5/8" 'TYPE-X' GYPSUM WALL BOARD O/

2x8" WOOD FRAMING (OR FRAMING THICKNESS AS

NECESSARY TO FULLY CONCEAL EXISTING COLUMN),

STUDS AT 2'-0" ON CENTER, W/

SOUND ATTENUATION BATTS AT CAVITY O/

5/8" 'TYPE-X' GYPSUM WALL BOARD

- INSTALL WALL FRAMING TO UNDERSIDE OF FLOOR STRUCTURE ABOVE (±10'-0" AFF) U.N.O.

- REFER TO A1.1 FOR FIRE-RESISTIVE RATED VOLUMES.

- PROVIDE ALL NECESSARY BLOCKING IN WALL. PROVIDE ACOUSTICAL JOINT SEALANT AT ALL SEAMS AND JOINTS IN ROOMS SPECIFIED.

5/8" 'TYPE-X' GYPSUM WALL BOARD O/

2x4" WOOD FRAMING STUDS AT 2'-0" ON CENTER, SOUND ATTENUATION BATTS AT CAVITY O/

5/8" 'TYPE-X' GYPSUM WALL BOARD

1/2" GYPSUM WALL BOARD LAMINATE O/

EXISTING WALL CONSTRUCTION

HATCH INDICATES APPROXIMATE EXTENT OF CONTRACTOR STAGING AREA.

PROTECT EXISTING IRRIGATION SYSTEM AND VEGETATION. RE-LANDSCAPE

ENTIRE COURTYARD FOLLOWING COMPLETION OF WORK. KEEP DUST TO A

MINIMUM AT ALL TIMES, TO THE SATISFACTION OF THE CONTRACTING OFFICER.

7 MINIMUM 60 STC RATING

1 LAYER, 5/8" GYPSUM WALL BOARD O/

ANOTHER LAYER 5/8" GYPSUM WALL BOARD

(STAGGER JOINTS) O/

CONTINUOUS EPDM SOUND BARRIER O/

2x4" WOOD FRAMING STUDS AT 24" ON CENTER

(STAGGER STUDS) W/

SOUND ATTENUATION BATTS AT CAVITY

(FILL CAVITY FULL, WRAP STUDS) O/

CONTINUOUS SOUND BATTIER O/

5/8" GYPSUM WALL BOARD

B U

IL

D

IN

G

P

H A

S E

B A

S E M

E N

T R

E N

O V

A T

IO

N

U S F

O R E S T

S E R

V

IC

E

N O

R T

H E R N

R E G

IO

N

R

E G

IO

N

A L O

F F

IC

E www.aearchitects.com

O W

N E

R

P R

O J E

C T

D R

A W

IN

G

A R C H I T E C T U R E

H I S T O R I C

I N T E R I O R S

ARCHITECTS P

C

608 NORTH 29TH STREET

BILLINGS, MT 59101

PH 4 0 6 . 2 4 8 . 2 6 3 3

FAX 4 0 6 . 2 4 8 . 2 4 2 7

428 EAST MENDENHALL STREET

BOZEMAN, MT 59715

PH 4 0 6 . 4 5 1 .7 3 1 0

222 NORTH HIGGINS AVENUE

MISSOULA, MT 59802

PH 4 0 6 . 7 2 1 . 5 6 4 3

FAX 4 0 6 . 7 2 1 . 1 8 8 7

PROJECT #

ISSUE DATE

REVISIONS

13104.20

02.12.16

CHRISTOPHER R. MARTISON

MONTANA

MISSOULA

AIA

CONTINUOUS 1 HR FIRE RESISTIVE RATED

CONSTRUCTION, FULL HEIGHT.

NEW PARKING AREA.

REFER TO CIVIL.

15'-0"

HOLD

FULLY OCCUPIED AREA, LIMITED ACCESS.

COORDINATE ALL ACCESS WITH OWNER.

(E) SIDEWALK TO REMAIN, PROTECT, TYP.

(E) SIDEWALK TO REMAIN, PROTECT, TYP.

FULLY OCCUPIED AREA, LIMITED ACCESS.

COORDINATE ALL ACCESS WITH OWNER.

FULLY OCCUPIED AREA, LIMITED ACCESS.

COORDINATE ALL ACCESS WITH OWNER.

(E) PARKING AREA

BUILDING 24

WASH BAY

(N) GATE, SEE CIVIL.

(N ) G

A T E

S E E C

IV

IL

(E) LANDSCAPING TO REMAIN, PROTECT.

(E) PARKING AREA

(E) PARKING AREA

HATCH INDICATES APPROXIMATE

EXTENT OF CONTRACTOR PARKING.

PROVIDE DUST-PROOF

PHYSICAL BARRIER

FOR DURATION OF

WORK. PROTECT

EXISTING FINISHES.

COORDINATE WITH

CONTRACTING

OFFICER.

36'-0"± VIF

(N) CONCRETE

10'-0"

HOLD

HISTORIC

BAKERY

RB EXT LCP

M D

M

PNL M1A PNL M2A

MDR

MDP

WHWH

RESTROOM

VESTIBULE

FACP

012.1

A D E F G H KCB I J

UP UP

BASEMENT DEMOLITION PLAN16

D2.0 : D2.0

B A

S E M

E N

T D

E M

O L

IT

IO

N

P L A

N

1/8" = 1'-0"

NORTH

1. FIELD VERIFY DIMENSIONS. DO NOT SCALE DRAWINGS. VERIFY EXISTING

CONDITIONS AND NOTIFY CONTRACTING OFFICER OF ANY DISCREPANCIES PRIOR TO

COMMENCING WORK.

3. COORDINATE ALL DEMOLITION WORK WITH EXISTING CONDITIONS AND NEW WORK

INDICATED.

4. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

5. PROVIDE SHORING AND BLOCKING NECESSARY TO MAINTAIN THE STRUCTURAL

INTEGRITY OF THE BUILDING. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL

INFORMATION.

6. ANY ITEM SHOWN OR REFERENCE IN ONE INSTANCE SHALL BE AS IF SHOWN IN ALL

INSTANCES.

7. REFERENCE TO A DEMOLITION PHOTOGRAPH.

8. PROTECT ALL EXISTING SURFACES AND FINISHES TO REMAIN.

9. SALVAGE ALL EXISTING 5-PANEL, 6-PANEL, AND HISTORIC HALF-LITE DOORS.

10. WHERE DEMO IS INDICATED, REMOVE ALL ASSOCIATED COMPONENTS, INCLUDING

FASTENERS, BLOCKING, AND SIMILAR, THAT NO LONGER SERVE A PURPOSE,

COORDINATE WITH NEW WORK INDICATED.

11. ASBESTOS-CONTAINING MATERIAL AND LEAD PAINT PRESENT WITHIN BUILDING;

REFER TO REPORT.

DEMOLITION GENERAL NOTES

B U

IL

D

IN

G

P

H A

S E

B A

S E M

E N

T R

E N

O V

A T

IO

N

U S F

O R E S T

S E R

V

IC

E

N O

R T

H E R N

R E G

IO

N

R

E G

IO

N

A L O

F F

IC

E www.aearchitects.com

O W

N E

R

P R

O J E

C T

D R

A W

IN

G

A R C H I T E C T U R E

H I S T O R I C

I N T E R I O R S

ARCHITECTS P

C

608 NORTH 29TH STREET

BILLINGS, MT 59101

PH 4 0 6 . 2 4 8 . 2 6 3 3

FAX 4 0 6 . 2 4 8 . 2 4 2 7

428 EAST MENDENHALL STREET

BOZEMAN, MT 59715

PH 4 0 6 . 4 5 1 .7 3 1 0

222 NORTH HIGGINS AVENUE

MISSOULA, MT 59802

PH 4 0 6 . 7 2 1 . 5 6 4 3

FAX 4 0 6 . 7 2 1 . 1 8 8 7

PROJECT #

ISSUE DATE

REVISIONS

13104.20

02.12.16

CHRISTOPHER R. MARTISON

MONTANA

MISSOULA

AIA

X:XX.XX

DEMO (E) DOOR AND FRAME.

(E) DOOR TO REMAIN, PROTECT.

CAP AND FILL DRAINS, PATCH AND REPAIR CONCRETE, LEVEL FLOOR.

SALVAGE (E) HISTORIC DOOR AND HARDWARE TO OWNER.

HATCH INDICATES APPROXIMATE EXTENT TO SAW CUT AND REMOVE CONCRETE

WALL; DEMO CANNOT OCCUR DURING OCCUPIED HOURS. COORD. WITH

CONTRACTING OFFICER. PROTECT (E) ADJACENT COLUMNS AND BEAMS, TYP.

EXISTING WALL, FINISH, OR BUILT ITEM TO BE DEMOLISHED.

EXISTING WALL OR BUILT ITEM TO REMAIN, PROTECT.

HATCH INDICATES APPROXIMATE EXTENT OF WALL FRAMING

DEMOLITION.

EXISTING DOOR TO BE DEMOLISHED, UNLESS OTHERWISE NOTED.

DEMOLISH PLUMBING FIXTURES IN THEIR ENTIRETY, REFER TO

MECHANICAL / PLUMBING.

DEMOLITION KEYSYM.

(E) HISTORIC STAIR, NEWEL POSTS, BALUSTRADE, RAIL, RISERS, TREADS,

AND CARPET RUNNER TO REMAIN; PROTECT.

DEMOLITION KEYNOTE LEGEND

DESCRIPTIONSYMBOL

DEMO (E) FLOOR TRENCH DRAIN AND METAL GRATING. PATCH CONCRETE

LEVEL WITH ADJACENT.

REMOVE AND SALVAGE (E) HALF-LITE DOOR AND FRAME. PREP DOOR FOR

(N) DOOR HARDWARE AND REINSTALLATION.

D2.0

11 DEMO METAL FENCE AND/OR METAL GATE.

2 2

11 11

11 11

HATCH INDICATES APPROXIMATE EXTENT OF TERRACOTTA BLOCK

WALL DEMOLITION.

HATCH INDICATES APPROXIMATE EXTENT OF CONCRETE WALL

DEMOLITION. DEMO TO OCCUR OUTSIDE REGULAR BUSINESS HOURS.

HATCH INDICATES APPROXIMATE EXTENT OF CMU BLOCK WALL

DEMOLITION. DEMO TO OCCUR OUTSIDE REGULAR BUSINESS HOURS.

8:

D 9.

EXISTING FAN AND WINDOW INFILL TO BE DEMOLISHED.

:D

.1

:D .1

11:D9.1

:D .1

20:D 9.

:D .1

:D .1

:D

.1

:D

9.

9:D9.1

DEMO CMU BLOCK ENCLOSURE, PLYWOOD CEILING, METAL GATES, CAGE

AND ASSOC. HARDWARE. PROTECT (E) STEEL COLUMNS AND BEAMS, TYP.

EXISTING COLUMNS TO REMAIN, PROTECT.

TYP.

DEMOLISH EXISTING DOUBLE FRENCH IN-SWING CASEMENT WINDOW

UNIT. SALVAGE ALL WINDOW STAYS/HOLD-OPENS FOR RE-USE.

3:D 9.1

SIM.

DEMO (E) FLOOR BENCHES. PATCH AND REPAIR FLOOR, AS NECESSARY.

DEMO TERRA COTTA BLOCK WALL. PROTECT (E) COLUMNS AND BEAMS, TYP.

11 11

4 7

DEMO (E) WOOD WALL FRAMING AND MISC. BLOCKING WITHIN ROOM, TO (E)

ORIGINAL PLASTER/CONCRETE WALLS.

DEMO (E) FLOOR SINK, REFER TO PLUMBING. PATCH AND REPAIR CONCRETE,

LEVEL FLOOR.

4'-2"

4'-2"

DEMO (E) RADON PIPING AND FAN MONITORING EQUIPMENT AT BUILDING

INTERIOR, SALVAGE FAN MONITORING EQUIPMENT FOR REINSTALLATION.16

(E) COLUMN TO REMAIN, PROTECT.17

APPROX. EXTENT OF EXCAVATION FOR NEW LOADING DOCK.18

17 17

17 17

17 17

DEMO (E) CONCRETE FLOOR SLAB, THIS AREA FOR NEW PLUMBING AND

SHOWER DRAINS.

DEMO (E) GREASE TRAP AND LID. CAP AND FILL. PATCH TO MATCH (E)

ADJACENT FLOOR LEVEL, REFER ALSO TO PLUMBING.20

(E) HISTORIC STAIR, TREADS, RAILS TO REMAIN, PROTECT.21

DEMO (E) CASEWORK AND ALL ASSOCIATED TOILET ACCESSORIES.22

DEMO (E) RAISED INTERIOR CONCRETE LIP AT DOOR.23

DEMO (E) WOOD PANELING WITHIN ROOM.24

DEMO (E) CONCRETE FLOOR AS NECESSARY FOR (N) RAMP.

21 21

23 23

3'-4"± 3'-4"±

3'-4"±

NOTE: ALL MAJOR CONCRETE

DEMOLITION, INCLUDING ALL CONCRETE

WALLS AND SLABS, SHALL OCCUR

OUTSIDE REGULAR BUSINESS HOURS AND

BE COORDINATED WITH CONTRACTING

OFFICER 7-DAYS IN ADVANCE OF WORK.

1ST FL.

1ST FL.

:D

.1

:D .1

:D

.1

:D

.1

16:D9.1

C O

O R D

W

(N

W O

R K

T Y P

C O

O R D

W

(N

W O

R K

A D E F G H KCB I J

DEMO BASEMENT FLOOR REFLECTED CEILING PLAN16

D2.0 : D7.0

D E M

O B

A S E M

E N

T F

L O

O R

R E F L E C

T E D

C E

IL

IN

G

P L A

N

1/8" = 1'-0"

NORTH D7.0

B U

IL

D

IN

G

P

H A

S E

B A

S E M

E N

T R

E N

O V

A T

IO

N

U S F

O R E S T

S E R

V

IC

E

N O

R T

H E R N

R E G

IO

N

R

E G

IO

N

A L O

F F

IC

E www.aearchitects.com

O W

N E

R

P R

O J E

C T

D R

A W

IN

G

A R C H I T E C T U R E

H I S T O R I C

I N T E R I O R S

ARCHITECTS P

C

608 NORTH 29TH STREET

BILLINGS, MT 59101

PH 4 0 6 . 2 4 8 . 2 6 3 3

FAX 4 0 6 . 2 4 8 . 2 4 2 7

428 EAST MENDENHALL STREET

BOZEMAN, MT 59715

PH 4 0 6 . 4 5 1 .7 3 1 0

222 NORTH HIGGINS AVENUE

MISSOULA, MT 59802

PH 4 0 6 . 7 2 1 . 5 6 4 3

FAX 4 0 6 . 7 2 1 . 1 8 8 7

PROJECT #

ISSUE DATE

REVISIONS

13104.20

02.12.16

CHRISTOPHER R. MARTISON

MONTANA

MISSOULA

AIA

DEMO EXISTING CEILING FINISHES, ALL ASSOCIATED

FASTENERS/HANGERS, AND MISC. BLOCKING THIS AREA.

RCP DEMO LEGENDSYM.

DEMOLITION KEYNOTE LEGEND

DESCRIPTIONSYMBOL

(E) LIGHTING TO REMAIN, THIS AREA, PROTECT.

EXISTING PLASTER CEILING FINISH TO REMAIN, PROTECT TO THE

GREATEST EXTENT POSSIBLE. COORDINATE ALL WORK,

INCLUDING STRUCTURAL, MECHANICAL/PLUMBING, AND

ELECTRICAL, TO MAINTAIN STRUCTURAL INTEGRITY OF EXISTING

PLASTER CEILINGS, TYP.

1. WHERE DEMO IS INDICATED, REMOVE ALL ASSOCIATED COMPONENTS,

INCLUDING FASTENERS, BLOCKING, AND SIMILAR, THAT NO LONGER SERVE A

PURPOSE, COORDINATE WITH NEW WORK INDICATED, TYP.

2. EXISTING PLASTER CEILINGS REMAIN THROUGHOUT ENTIRE BUILDING. PAINT IS

FLAKING AND PORTIONS OF EXISTING HISTORIC PLASTER FINISH ARE

DELAMINATING. PRIOR TO INSTALLATION OF NEW CEILING MATERIALS, REMOVE

FLAKING OR LOOSE PAINT AND PLASTER TO SOUND PLASTER MATERIAL (FOR

BIDDING PURPOSES, ASSUME 60% OF THE PLASTER CEILING WITHIN PHASE 3

WORK).

DEMO RCP GENERAL NOTES

DEMO (E) CAST IRON CEILING RADIATOR. RECYCLE AS SPECIFIED.

DEMO ASSOCIATED STEAM PIPING IN ENTIRETY, REFER TO

MECHANICAL. PATCH AND PREP CEILING FOR NEW WORK. REFER TO

STRUCTURAL.

(E) CAST IRON CEILING GREASE PAN TO REMAIN. CLEAN.

DEMO EXISTING LIGHT FIXTURE. REFER TO ELECTRICAL.

DEMO (E) DROP-CEILING, ASSOCIATED FASTENERS/HANGERS, AND MISC.

BLOCKING WITHIN THIS ROOM TO ORIGINAL PLASTER CEILING.

HATCH INDICATES SELECTIVE DEMO OF (E) PLASTER CEILING AND WALL

FINISHES, THIS AREA, FOR (N) STRUCTURAL CONNECTION.

333333

3 33

3 3

3 3 3

3 3

1 1

DEMO (E) FRAMED HEADER AND TRIMS.

4 4

SELECTIVELY DEMOLISH (E) PLASTER CEILING TO INSTALL MECHANICAL

EXHAUST FAN WITHIN JOIST SPACE. PATCH AND REPAIR PLASTER CEILING

WITHIN ROOM TO MATCH (E), IN-KIND.

3'-4"

13104.3 ARCH_Part2
13104.3 ARCH_Part3
13104.3 ARCH_Part4

File details come from the government source that posted it. Updated .