SUPPORTING DOCUMENT – G

AG-0261-S-16-0047

SEASONAL BUNKHOUSE HOUSING 2016

SALMON CHALLIS AND SAWTOOTH NF

STANLEY SEASONAL HOUSING DRAWINGS

18 Pages (including this header page)

GENERAL NOTES:

1. AN EXTENSIVE EFFORT HAS BEEN MADE TO LOCATE ALL POSSIBLE EXISTING UTILITY LINES FROM

RECORDS AND EVIDENCE IN THE FIELD, HOWEVER, THE COMPLETENESS OR ACCURACY OF THE

LOCATIONS SHOWN CANNOT BE GUARANTEED. THE CONTRACTOR IS RESPONSIBLE FOR

ESTABLISHING THE LOCATION OF ALL EXISTING UTILITIES. ANY LOCATION STAKED OR SHOWN IS

APPROXIMATE. CALL 811 TO HAVE UTILITIES MARKED BEFORE BEGINNING CONSTRUCTION. IF

CONFLICTS ARE FOUND, NOTIFY THE CONTRACTING OFFICER.

2. INFRASTRUCTURE SUCH AS: ELECTRICAL, SEWER, WATER AND PHONE LINES EXIST. THE

CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING OFFICER'S REPRESENTATIVE TO

LOCATE, PRESERVE, AND INTERRUPT ANY OF THE CURRENT SERVICES.

3. SEE "E" SHEETS FOR ELECTRICAL DESIGN.

4. ALL OBLITERATED ROAD BASE ROAD MATERIALS SHALL BE REUSED AS ROAD BASE MATERIAL OR

AS OTHER FILL MATERIAL IN APPROPRIATE AREAS. THE CONTRACTOR SHALL REMOVE AND

STOCKPILE ROAD BASE FOR REUSE, AND USE AS CRUSHED AGGREGATE BASE COURSE IN THE

CONSTRUCTION OF THE NEW PARKING AREA.

5. ALL CLEARING AND GRUBBING SHALL CONFORM TO SECTION 311000 IN THE SPECIFICATIONS. ALL NON-SALVAGEABLE MATERIAL SHALL BE DISPOSED OF AT THE STANLEY ADMINISTRATIVE SITE .

6. CONTRACTOR SHALL MINIMIZE OUTAGES AND ACCESS DISTURBANCE TO THE EXISTING FACILITIES.

ALL DISRUPTIONS TO THE EXISTING FACILITIES MUST BE COORDINATED THROUGH THE C.O.R.

7. STAKING WILL BE COMPLETED BY THE CONTRACTOR AND APPROVED BY THE CONTRACTING

OFFICER'S REPRESENTATIVE.

8. THE CONTRACTOR SHALL FINISH GRADE THE SITE TO DRAIN AS SHOWN ON THE DRAWINGS. THE

PROPOSED CONTOURS ARE GENERALIZATIONS AND MAY BE ADJUSTED BASED ON ACTUAL FILL

MATERIAL AVAILABLE AND AS APPROVED BY THE CONTRACTING OFFICER'S REPRESENTATIVE.

9. CONCRETE SIDEWALKS AND SLABS NEXT TO BUILDINGS SHALL BE SLOPED TO DRAIN AWAY FROM

THE BUILDING AT A MINIMUM OF 2 PERCENT.

10. ALL CUT SLOPES SHALL BE SLOPED AT 2:1 AND FILL SLOPES SHALL BE SLOPED AT 3:1 UNLESS

OTHERWISE INDICATED ON THE PLANS.

11. ALL WATERLINE SHALL BE SLOPED A MINIMUM 2% TO DRAIN.

12. BURY WATERLINE A MINIMUM OF 60 INCHES TO TOP OF PIPE. ADDITIONAL DEPTH MAY BE REQUIRED

TO MAINTAIN A MINIMUM SLOPE OF 2%.

13. THE MINIMUM ALLOWABLE BENDING RADIUS FOR HDPE PIPE IS 30 TIMES THE NOMINAL PIPE

DIAMETER.

NOM. PIPE DIA. MIN. BENDING RADIUS

1" 2'-6" 2" 5'-0" 3" 7'-6" 4" 10'-0" 6" 15'-0"

14. INSTALL THE WATER SYSTEM ACCORDING TO APPLICABLE FEDERAL, STATE AND LOCAL

REGULATIONS FOR PUBLIC DRINKING WATER SYSTEMS.

15. CLEARING LIMITS SHALL BE 5 FEET ON BOTH SIDES OF THE UTILITY TRENCH. THE CONTRACTOR

SHALL USE CAUTION AND AVOID DAMAGE TO TREES AND VEGETATION. THE CONTRACTOR SHALL

CONFINE ALL OPERATIONS AND ACTIVITIES TO WITHIN THE CLEARING LIMITS.

16. CONNECTIONS BETWEEN NEW AND EXISTING WATERLINES SHALL BE INSTALLED IN MANNER

RECOMMENDED BY THE PIPE MANUFACTURER AND APPROVED BY THE CONTRACTING

OFFICER. COMPRESSION-TYPE FITTINGS ARE NOT ALLOWED.

17. INSTALL THRUST BLOCKS FOR ALL 4" AND LARGER WATERLINES AT CHANGES IN DIRECTION

GREATER THAN 45 DEGREES AND AT ALL TEES.

18. WHERE NEW WATERLINES INTERSECT SEWERLINES, THE NEW WATERLINES SHALL BE INSTALLED ACCORDING TO APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS, INCLUDING: IDAHO DEQ IDAPA 58.01.08, RULES FOR PUBLIC DRINKING WATER SYSTEMS, SEE PIPE SEPARATION DETAIL, SHEET D5.

ABBREVIATION LEGEND:

SNRA..SAWTOOTH NATIONAL RECREATION AREA

N.I.C....NOT IN CONTRACT

CP ..... SURVEY CONTROL POINT

TBC ... TOP BACK OF CURB

BW..... BACK OF WALK

FG ...... FINISHED GRADE

BLDG.. BUILDING

FF ...... FINISHED FLOOR

FL ...... FLOW LINE

PC...... POINT OF CURVE

PT...... POINT OF TANGENT

POC... POINT ON CURVE

GRD... GROUND

EO..... EDGE OF ROAD

LPP... LIGHT UTILITY POLE

TPP... TELEPHONE UTILITY POLE

S ....... SLOPE

GB ..... GRADE BREAK

SD ..... STORM DRAIN

SS ..... SANITARY SEWER

W ...... WATER

MH..... MAN HOLE

(##) .. EXISTING ELEVATION

INV .... INVERT

CB .... CATCH BASIN

FNC.... FENCE

NEW WATERLINE

EXISTING WATERLINE

NEW SEWERLINE

EXISTING SEWERLINE

NEW STORM DRAIN

EXISTING STORM DRAIN

DRAINAGE FLOWLINE

NEW ELECTRICAL LINE

EXISTING POWER

EXISTING BURIED POWER

EXISTING OVERHEAD UTILITY

TELECOMMUNICATIONS LINE

EXISTING TELECOMMUNICATIONS LINE

NEW FENCE

EXISTING FENCE

NEW CURB VALVE AND BOX - SIZE VARIES

EXISTING VALVE

NEW WATER METER AND BOX

EXISTING SANITARY SEWER MANHOLE

NEW SANITARY SEWER MANHOLE

NEW CLEANOUT

EXISTING CLEANOUT

NEW PUMPOUT DRAIN

EXISTING STORM DRAINAGE MANHOLE

EXISTING POWER POLE

MAJOR CONTOUR AND ELEVATION (FEET)

CUT AND FILL SLOPE

W

W

S

S

SD

SD

LEGEND:

EXISTING ROAD AND PARKING AREAS

NEW AGGREGATE PARKING SURFACE

NEW LANDSCAPE AREA

NEW ACCESSIBLE PARKING STALL

NEW SIGN

NEW PARKING LOT LIGHT

NEW TELEPHONE PEDESTAL

E

E

OHP

T

T

X

X

EXISTING SURVEY CONTROL POINT

Point Table

Point #

Northing

10183.28

9999.97

9833.41

9747.79

9918.08

Easting

10000.00

10000.03

9813.37

9986.09

10182.51

Elevation

1008.27

999.90

1004.44

1005.31

997.09

Description

CP2

CP1

CP4

CP3

CP5

Point Table

Point #

Northing

10171.15

10189.89

10160.77

10142.03

10170.19

10180.45

10180.31

10172.07

10147.90

10128.39

10111.56

10098.15

10153.23

10157.49

10164.56

10183.97

10203.39

10203.25

10195.20

10183.28

9999.97

9833.41

9747.79

9918.08

Easting

9867.30

9849.27

9819.00

9837.03

9869.90

9889.00

9898.65

9903.69

9811.63

9819.60

9836.61

9850.75

9809.60

9805.50

9805.64

9825.82

9846.00

9853.07

9860.81

10000.00

10000.03

9813.37

9986.09

10182.51

Elevation

1014.50

1014.50

1014.50

1014.50

1013.00

1011.23

1010.39

1009.56

1012.50

1010.80

1009.60

1008.50

1012.50

1012.50

1012.50

1012.50

1012.50

1012.50

1012.50

1008.27

999.90

1004.44

1005.31

997.09

Descriptio

BLDG

BLDG

BLDG

BLDG

PATH

PATH

PATH

PATH

SWALE

SWALE

SWALE

SWALE

TOE

TOE

TOE

TOE

TOE

TOE

TOE

CP2

CP1

CP4

CP3

CP5

S

S

C

M

M

S

S

S

TAMPER SWITCH

AND FLOW SENSOR

ACTIVATE BELL ONLY

SPRINKLER FLOW

ALARM BELL

A-11

A-7A-1

A-1

A-2

A-15,17

A-10

A-1

GENERAL ELECTRICAL NOTES

1. BUILDING ELECTRICAL SERVICE SHALL BE A FEEDER FROM AN

ELECTRICAL SERVICE LOCATION INSTALLED BY OTHERS. AT BUILDING

LOAD CENTER:

1.1. ENSURE NEUTRAL BONDING IS REMOVED.

1.2. INSTALL AN EQUIPMENT GROUND BAR. THIS IS NOT THE REQUIRED

INTERSYSTEM BONDING TERMINATION, SEE NEC 250.94.

1.3. KEEP NEUTRALS, AND, EQUIPMENT AND GROUNDING ELECTRODE

CONDUCTORS SEPARATE.

1.4. GROUNDING ELECTRODE CONDUCTOR(S) AND BUILDING FEEDER

EQUIPMENT GROUNDING CONDUCTOR SHALL TERMINATE IN THE

EQUIPMENT GROUND BAR.

2. ELECTRICAL FEEDERS SHALL BE KEPT 36-INCHES FROM WATER OR GAS

SERVICES.

3. ELECTRICAL EQUIPMENT SHALL BE 10,000 AMP SHORT CIRCUIT RATED,

SQUARE D QO OR BETTER, NO TANDEM OR HALF SIZED BREAKERS

ALLOWED.

4. HOME RUN INTERNAL PHONE TO MAIN DISCONNECT LOCATION INTO

COMBINER/SERVICE BOX. GROUND PER CODE AND SPECIFICATIONS.

5. HOME RUN TELEVISION INTERNAL CABLE TO SURGE ARRESTOR MOUNTED

NEAR MAIN DISCONNECT LOCATION FOR CABLE TV OR SATELLITE

SERVICE. GROUND PER CODE AND SPECIFICATIONS.

6. ELECTRICAL IN HOUSING SHOWN IS A MINIMUM AND MAY VARY BASED ON

SUBMITTED FLOOR PLANS. IF ALTERNATIVE SIZED BUILDING IS

APPROVED, ELECTRICIAN SHALL SUBMIT MODIFIED ELECTRICAL PLAN.

ADDITIONAL LUMINAIRES AND OR TYPE CHANGES MAY BE REQUIRED AT

NO ADDITIONAL COST TO PROVIDE THE SAME LEVEL OF SERVICE.

ADDITIONAL RECEPTACLES MAY ALSO BE REQUIRED TO MEET INTENT AS

SHOWN.

7. A RANGEHOOD IN ADA UNITS SHALL BE WIRED AS DESCRIBED TO DOUBLE

SWITCH IN CABINET FRONT.

8. SMOKE, CARBON MONOXIDE, AND VISUAL ALARMS SHALL ALL BE

INTERCONNECTED.

LOAD CENTER DISTRIBUTION

THE FOLLOWING IS A LIST OF COMMON CIRCUITS MINIMUM:

# AMPS DESCRIPTION

A-1 20 ADA BEDROOM LIGHTS AND RECEPTACLES

AND EXTERIOR AND MECH ROOM

RECEPTACLES

A-16 20 FAR BEDROOMS LIGHTS AND

RECEPTACLES AND EXTERIOR

RECEPTACLE

A-2 20 RECEPTACLE-ADA BATHROOM

A-3 20 ALL LIGHTS AND FANS EXCEPT BEDROOMS

A-4 20 RECEPTACLE-FAR BATHROOM

A-5 20 FRIDGE AND RANGE HOOD

A-6 20 RECEPTACLES-KITCHEN LEFT SIDE

A-7 20 FREEZER

A-8 20 RECEPTACLES-KITCHEN RIGHT SIDE

A-9 20 RECEPTACLES-LIVING ROOM AND HALL

A-10 20 RECEPTACLES-KITCHEN ISLAND

A-11 20 RECEPTACLES-WASHER AND LAUNDRY

A-12,14 30 RECEPTACLE-DRYER

A-13 15 SMOKE ALARMS, ALARM BELL CIRCUIT

A-15,17 50 RANGE

A-19 20 DISHWASHER

A-18,20 30 WATER HEATER

A-21 15 FURNACE

REQUIRED CRAWL SPACE AND ATTIC SPACE LIGHTING AND

RECEPTACLES AS DESCRIBED MAY BE PLACED ON OTHER

CIRCUITS.

SERVICE CALCULATIONS

NEC 220.82

(3VA/FT2)(1099FT2)= 3,297

(1.5KW)(3 SMALL APPL)= 4,500

(1.5KW)(1 LAUNDRY)= 1,500

REFRIGERATOR & FREEZER= 1,200

DRYER= 5,000

DISHWASHER= 1,200

RANGE= 12,000

FURNACE= 1,180

WATER HEATER= 4,500

TOTAL VA= 34,377

10,000 @ 100% 10,000 24,377 @ 40% 9,751

TOTAL VA= 19,751 82 AMPS

MAIN BREAKER AND PANEL SHALL BE 125 AMP MINIMUM

120/240 VAC SINGLE PHASE.

PANEL SHALL BE LARGE ENOUGH TO ACCOMMODATE 5

BLANK BREAKER SPACES BEYOND INSTALLED BREAKERS

FOR FUTURE FEEDER AND OTHER POSSIBLE LOADS.

A-16

A-16

A-16

A-16

A-16

A-16

A-1

A-16

WATER HEATER AND

FURNACE REQUIRE

DISCONNECTS

A-10

A-10

UNDER THE

SINK FOR

DISHWASHER

THESE RECEPTACLES

ARE ABOVE THE

EATING SPACE

A-1

TYPE DESCRIPTION MANUFACTURER MODEL # LAMPS MOUNTING Qty NOTES:

A LINEAR FLUORESENT LITHONIA LB 232 GEB (2) 32W T8 CW SURFACE/CEILING 4

B LINEAR FLUORESCENT LITHONIA LB 432 GEB (4) 32W T8 CW SURFACE/CEILING 3

C DOWN LIGHT HALO H270ICAT - 470SC (1) 13W Q CF CW RECESSED/CEILING 2

E ROUND CLOSE TO CEILING LED INCON LIGHTING 11111 213QE (1) 13W Q CF CW SURFACE/CEILING 2

G DARK SKY COMPLIANT LED INCON LIGHTING 74093B 15LED LED SURFACE/WALL 2

N KEYLESS ANY (1) 18W CFL SURFACE/CEILING 5 PULL CHAIN REQUIRED ONLY FOR LUMINAIRE IN MECH ROOM

X EXIT SIGN LITHONIA EXG LED EL M6 LED BACK MOUNT 1

TOTAL 19

FF BATH FAN (NO LIGHT) BROAN AE80 CEILING 2

CRAWL SPACES AND ATTIC SPACES LIGHTING AND RECEPTACLES

1- AT CRAWL AND ATTIC ACCESS, INSTALL ONE GFCI RECEPTACLE AND SINGLE POLE PILOT SWITCH ON THE

CIRCUIT SERVING THE ROOM WITH THE ACCESS ONLY ACCESSIBLE FROM WITHIN THE SPACE.

2- SWITCH SHALL CONTROL 2 TYPE "N" LUMINAIRES LOCATED TO LIGHT THE SPACE. LOCATIONS SHALL BE

APPROVED BY THE CONTRACTING OFFICER BEFORE INSTALLATION.

C

C

M

S

A-3

SA-3

B

S

A-16 B

J

A-5S

S

A-16

S

FF

A-3

B

S

A-3

S

S

FF

A-3

E

E

S

S

A

N

CONTROL WITH PULL

CHAIN, LOCATE TO

PROVIDE LIGHT FOR

ENTIRE ROOM

A

GG

A

A

A-3

A-3

X

SEE LEGEND FOR

MORE INFORMATION

C

M