CRDBunkhouse_final_drawings_061710.pdf
PDF 4 MB Posted
- Solicitation number
- AG-0120-S-11-0032
About this file
AG-0120-S-11-0032 Project Drawings CWC 12 Person Bunkhouse Retrofit
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AG0120S110032_Amend002_SF30.pdf | ||
| AG0120S110032ConfCallAtndeList.pdf | ||
| AG0120S110032ConfCall_AgendaMtgNotes.pdf | ||
| WDOL_GnlDec_AK1_Mod33_19Aug2011.pdf | ||
| AG0120S110032_CWCBunkhouse_SF1442.pdf | ||
| AG0120S110032SiteAtndeList083111.pdf | ||
| AG0120S110032_Amend001.pdf | ||
| AG0120S110032_SiteVisitNotes.pdf | ||
| laundry room with floor hatch.JPG | JPG image | |
| tv room.JPG | JPG image | |
| west end bathroom.JPG | JPG image | |
| kitchen 2.JPG | JPG image | |
| entry interior.JPG | JPG image | |
| exterior1.JPG | JPG image | |
| west end from entryway.JPG | JPG image | |
| hallway with fire door.JPG | JPG image | |
| kitchen 1.JPG | JPG image | |
| west end bedroom one of two.JPG | JPG image | |
| west end foyer.JPG | JPG image | |
| west end shower room.JPG | JPG image | |
| entry.JPG | JPG image | |
| pantry.JPG | JPG image | |
| errata_cwc12personbunkhouseaccessretrofit_081211.pdf | ||
| CRDBunkhouse_final_specifications_081211.pdf | ||
| AG0120S110032_CWCBunkhouse_ReturnPkg.pdf | ||
| revised_M3.00_081211.pdf | ||
| revised_E3.00_081211.pdf | ||
| AG0120S110032_CWCBunkhouseRFP_FNL.pdf |
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1t
1i
1 View Name 1/8" = 1'-0"
Room Name
A101
SIM
NORTH
101Ref
A101
A7.01 1
A7.024
BUILDING SECTION
CALLOUT MARK
DETAIL CALLOUT
MARK
EXTERIOR ELEVATION
CALLOUT MARK
INTERIOR ELEVATION
CALLOUT MARK
ROOM TITLE TAG
DOOR TAG
WINDOW TAG
WALL TYPE TAG
REFERENCE NORTH
ARROW
TITLE MARK
5/8" TYPE 'X' GWB
2x4 WOOD STUD
5/8" TYPE 'X' GWB
5/8" TYPE 'X' GWB
2x6 WOOD STUD
5/8" TYPE 'X' GWB
R-13 UNFACED MINERAL
WOOL
5/8" TYPE 'X' GWB
2x4 WOOD STUD
R-13 UNFACED
MINERAL WOOL BATT
5/8" TYPE 'X' GWB
2x6 WOOD STUD
5/8" TYPE 'X' GWB
5/8" TYPE 'X' GWB
A4
A6
B4
B6
* INDICATES FULL HEIGHT WALL WITH GYP
TO UNDERSIDE OF DECK, TYP.
GA WP3644 ONE HOUR RATED
GA WP3660 ONE HOUR RATED
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
NTS G0.02
GENERAL INFORMATION SHEET
DN
04.06.2010
Designer
LS
GENERAL NOTES
1. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE CODES.
2. THE ORGANIZATION OF DOCUMENTS ARE NOT INTENDED TO CONTROL THE
DIVISION OF WORK. DIVISION OF WORK SHALL BE THE SOLE RESPONSIBILITY OF
THE CONTRACTOR.
3. DIMENSIONS ARE TO FACE OF STUD, FACE OF MASONRY, FACE OF CONCRETE
OR GRID LINE AT NEW CONSTRUCTION AND FACE OF EXISTING FINISH AT EXISTING
CONSTRUCTION UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL VERIFY DIMENSIONS, REQUIRED CLEARANCES, AND
POWER AND PLUMBING REQUIREMENTS FOR ALL OWNER AND N.I.C. ITEMS. NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES PRIOR TO COMMENCEMENT OF
WORK.
5. EXISTING CONDITIONS SHOWN ARE BASED ON RECORD DRAWINGS AND / OR
ORIGINAL CONSTRUCTION DRAWINGS. CONTRACTOR SHALL VERIFY EXISTING
CONDITIONS PRIOR TO COMMENCEMENT OF WORK. NOTIFY CONTRACTING OFFICER
OF ANY DISCREPANCIES PRIOR TO COMMENCEMENT OF WORK.
6. COORDINATE DELIVERY OF NEW ONE PIECE FIBERGLASS SHOWER W/
REMOVAL OF EXISTING WINDOWS TO ENSURE SHOWER UNIT CAN BE MOVED INTO
BUILDING THROUGH WINDOW OPENING PRIOR TO INFILL.
DRAWING SYMBOLS
WALL TYPES
DN
DEMOLITION LEGEND
EXISTING CONSTRUCTION TO REMAIN
EXISTING PARTITION, DOOR AND/OR FRAME TO BE REMOVED
EXISTING MILLWORK OR CEILING TO BE REMOVED
AREA INCLUDED IN CONTRACT
AREA OF LIMITED SCOPE OR N.I.C.
EXISTING DIMENSIONS, SHOWN FOR PLANNING PURPOSES ONLY
(E)
EXISTING GB CEILING TO REMAIN PATCH & REPAIR @ NEW CONSTRUCTION
0" (E
111' - 2 1/4" (E)
1/D1.021/D1.01
1/D1.01 1/D1.02
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
As indicated D1.00
OVERALL DEMOLITION PLAN
DN
04.06.2010
Designer
LS
1/8" = 1'-0"1 OVERALL DEMOLITION PLAN
NORTH
WH
EXISTING CONSTRUCTION TO REMAIN
EXISTING PARTITION, DOOR AND/OR FRAME TO BE REMOVED
EXISTING MILLWORK OR CEILING TO BE REMOVED
AREA INCLUDED IN CONTRACT
AREA OF LIMITED SCOPE OR N.I.C.
EXISTING DIMENSIONS, SHOWN FOR PLANNING PURPOSES ONLY
(E)
EXISTING GB CEILING TO REMAIN PATCH & REPAIR @ NEW CONSTRUCTION
8'
- 0
E)
2 1 /4"
(E
19' - 6 1/4" (E) 10' - 0 1/4" (E) 14' - 11 3/4" (E)
DEMOLISH & REMOVE ALL
INTERIOR NON-LOADBEARING
CONSTRUCTION WEST OF ENTRY
OPENING: REMOVE DOORS,
CASEWORKS, PLUMBING
FIXTURES, FLOOR & CEILING
FINISHES, & ALL RELATED
PLUMBING AND ELECTRICAL.
18' - 10 1/2" (E) 11' - 3 3/4" (E)
SALVAGE & REMOVE EXISTING
DOOR & FRAME. REMOVE CLOSER
PRIOR TO RE-INSTALLATION
DEMOLISH &
REMOVE DOOR
FRAME, PREP FOR
RELOCATION AS
SHOWN ON A1.01
DEMOLISH & REMOVE ALL
EXISTING CABINETS,
COUNTERTOPS & QUARRY TILE
BASE IN KITCHEN TEMP. STORE
REFRIGERATORS
FOR REUSE
14' - 7 1/2" (E) 8' - 0" (E)
CUT EXISTING
SHELVING &
REINSTALL
2'
- 0
REMOVE EXISTING
RANGES & TURN
OVER TO OWNER
FOR SALVAGE
DEMOLISH & REMOVE
EXISTING SINK & PREP
PLUMBING FOR INSTALLATION
OF NEW SINK
EXISTING WALL FINISH
TO REMAIN ON
EXTERIOR WALLS
EXISTING WALL FINISH
TO REMAIN ON
EXTERIOR WALLS
REMOVE EXISTING
GRATING AT PORCH
REMOVE EXISTING METAL
STAIRS, TREADS & STRINGERS
REMOVE ENTIRE WALL ON
WEST SIDE OF PORCH BELOW
HEADER
REMOVE EXISTING OVERHEAD
ROLLING DOOR & KITCHEN
COUNTERTOP
REMOVE PLUMBING
PIPING IN WALL TO
UNDERSIDE OF FLOOR -
PREP FOR RELOCATION
OR CAP WHERE NOT
USED IN NEW
CONSTRUCTION
REMOVE GWB & FRP
FINISH FROM THIS
FACE
5' - 6"
3'
- 6
"REMOVE EXISTING
WINDOW AND TRIM
AND PREP OPENING
FOR NEW WINDOW
INSTALLATION -
SALVAGE AND REMOVE
WINDOW TREATMENTS
AND STORE FOR
REINSTALLATION AT
NEW CONSTRUCTION
EXISTING WINDOWS
TO BE REMOVED
AND INFILLED
A7.02
REMOVE 18'-10 1/2" VINYL SIDING
FULL HEIGHT OF EXTERIOR WALL
REMOVE EXISTING FLOOR
FINISHES IN ENTRY & PORTION
OF TV ROOM
1/D1.021/D1.01
1/D1.01 1/D1.02
8'
- 1
1/ 8"
(E
1 1 /8"
(E
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
EGRESS WINDOWS4-30-20101
As indicated D1.01
DEMOLITION PLAN - WEST
DN
04.06.2010
Designer
LS
3/16" = 1'-0"1 DEMOLITION PLAN - WEST
EXISTING CONSTRUCTION TO REMAIN
EXISTING PARTITION, DOOR AND/OR FRAME TO BE REMOVED
EXISTING MILLWORK OR CEILING TO BE REMOVED
AREA INCLUDED IN CONTRACT
AREA OF LIMITED SCOPE OR N.I.C.
EXISTING DIMENSIONS, SHOWN FOR PLANNING PURPOSES ONLY
(E)
EXISTING GB CEILING TO REMAIN PATCH & REPAIR @ NEW CONSTRUCTION
21' - 3 3/4" (E) 12' - 0" (E)
7 1 /4"
(E
3'
- 5
7/ 8"
(E
1 1 /8"
(E
20' - 10 1/2" (E)
SALVAGE & REMOVE EXISTING
WASHERS & DRYERS. TURN
OVER TO OWNER.
3' - 7 1/4" (E)
SALVAGE & REMOVE EXISTING
LAUNDRY TUB FOR RELOCATION.
PERMANENTLY CAP EXISTING
PLUMBING UNDER FLOOR
EXISTING CRAWL SPACE
ACCESS HATCH TO REMAIN IN
PLACE. SEE DEMO NOTE 1.
REMOVE FLOOR FINISH IN
CORRIDOR ONLY AS REQUIRED
FOR WALL REMOVAL
7' - 0"
REMOVE DOOR FRAME: STRUCT
JAMB TO REMAIN THIS SIDE
REMOVE ALL FLOOR FINISHES
IN SHADED AREA.
1/D1.021/D1.01
1/D1.01 1/D1.02
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
As indicated D1.02
DEMOLITION PLAN - EAST
DN
04.06.2010
Designer
LS
3/16" = 1'-0"1 DEMOLITION PLAN - EAST
NORTH
1. CONTRACTOR TO VERIFY LOAD LIMITS OF
EXISTING ACCESS HATCH FOR INCREASED FOOT
TRAFFIC - REPLACE HATCH IF IT IS NOT RATED
FOR HEAVY TRAFFIC AREAS.
NOTES:
REMOVE GWB CEILING
ONLY AS NECESSARY
TO RELOCATE WALL.
PATCH & REPAIR.
REMOVE CEILING
ONLY AS
NECESSARY TO
RELOCATE WALL AT
TV ROOM. PATCH &
REPAIR EXISTING
FINISHES.
DEMOLITION LEGEND
EXISTING CONSTRUCTION TO REMAIN
EXISTING PARTITION, DOOR AND/OR FRAME TO BE REMOVED
EXISTING MILLWORK OR CEILING TO BE REMOVED
AREA INCLUDED IN CONTRACT
AREA OF LIMITED SCOPE OR N.I.C.
EXISTING DIMENSIONS, SHOWN FOR PLANNING PURPOSES ONLY
(E)
EXISTING GB CEILING TO REMAIN PATCH & REPAIR @ NEW CONSTRUCTION
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
As indicated D1.10
DEMOLITION REFLECTED CEILING PLAN
DN
04.06.2010
Designer
LS
1/8" = 1'-0"1 REFLECTED CEILING PLAN DEMOLITION
REF. REF. REF.
WH
DW
WWDD
DN
DNDN
BEDROOM
BEDROOM
TOILET
KITCHEN
6 PANTRY
LAUNDRY
ROOM
7' - 0 3/4"
8'
- 0
E)
1/A1.021/A1.01
ENTRY
HALL
E8
E21
E20E119E18E17
E16E15
E10
E12
E11
E22
E13
TOILET
111' - 2 1/4" (E)
2 1 /4"
(E
2 1 /4"
(E
ENTRY
DN
DN LOUNGE
TV ROOM
1/A1.01 1/A1.02
SHADING INDICATES AREAS OF NEW CONSTRUCTION
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
As indicated A1.00
OVERALL FLOOR PLAN
DN
04.06.2010
Designer
LS
1/8" = 1'-0"1 OVERALL FLOOR PLAN
REF. REF. REF.
DW
DN
DNDN
A2.00
A2.00
A8.01
NEW RAMP AND NEW STEEL
STAIR AS INDICATED
REPLACE SLIDING
POCKET DOOR TRACK
PROVIDE NEW
COUNTERTOP THROUGH
OPENING AS INDICATED
REINSTALL
SALVAGED DOOR
WITHOUT CLOSER
A8.00 2
A1.40
5E12
E10
3 4
BEDROOM
TOILET
BEDROOM
KITCHEN
PANTRY
3'
- 2
3'
- 0
C
AS
ED
O
PE
N
IN
G
AL
IG
N
A8.013
B4*
B4*
B4*
B6*
NEW STEEL BOLLARD 1
A7.00
NEW FLOOR GRATE OVER
MODIFIED EXISTING FLOOR JOIST,
SEE 1/A7.00
HALL
A8.022
6 B6*
A4
TOILET
A7.01
2'
- 1
0 1 /2"
INFILL & REPAIR QT
FLOOR WHERE CABINETS
ARE REMOVED.
A7.01
REINSTALL SALVAGED
PLYWD WALL PANELS
OVER NEW GWB TO AREA
SHOWN DASHED.
NOTE 1
NOTE 1
NOTE 1
NOTE 1
NOTES
1. PAINT DOOR AND FRAME OR
CASED OPENING, PT3
1"
B4*
6' - 3" 7' - 4"
A7.01
SIM
A3.00
EXISTING STEEL
PIPE COLUMNS
TO REMAIN
A7.00
DN
DN
ENTRY
B4*
B4*
A6
CL
EA
R
2'
- 9
3/ 8"
M
IN
A4
A4
A6
LOUNGE
TV ROOM
1/A1.021/A1.01
1/A1.01 1/A1.02
" M
IN
C
LR
A8.00
A7.01
A3.00
A3.00
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
EGRESS WINDOWS4-30-20101
3/16" = 1'-0" A1.01
FLOOR PLAN - WEST
DN
04.06.2010
Designer
LS
3/16" = 1'-0"1 FLOOR PLAN - WEST - OPTION A
WWDD
RELOCATE UTILITY SINK TO
SOUTH SIDE OF ROOM AS
INDICATED - CAP PLUMBING
AND REPAIR FLOOR AND
WALLS AS REQUIRED
2' - 4"
NEW WASHERS AND DRYERS (NIC)
AT NORTH SIDE OF ROOM AS
INDICATED - REPAIR FLOOR AND
WALLS AS REQUIRED
7' - 6"
LAUNDRY
ROOM
E8
A4
A7.01
ENTRY
1/A1.021/A1.01
1/A1.01 1/A1.02
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
3/16" = 1'-0" A1.02
FLOOR PLAN - EAST
DN
04.06.2010
Designer
LS
3/16" = 1'-0"1 FLOOR PLAN - EAST
8' - 0"
8' - 0"
8' - 0"
7' - 6"
A7.00
PATCH & REPAIR
EXISTING GWB CLG
AS REQUIRED AT
WALL RELOCATION,
PAINT ENTIRE
CEILING IN BOTH
ROOMS
PATCH & REPAIR EXISTING ACT
CLG WITH LIKE MATERIAL
8' - 0"
8' - 0"
8' - 0"
8' - 0"
PATCH & REPAIR
EXISTING GWB CLG
AS REQUIRED,
PAINT ENTIRE
CEILING
FEATHER NEW
GWB INTO
EXISTING CEILING
ALIGN NEW 6x6 WITH EXISTING 2x6 STUD
WALL ON PORCH
NEW 2' x 4' ACT
IN BEDROOMS
SOFFIT
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
1/8" = 1'-0" A1.10
REFLECTED CEILING PLANS
DN
04.06.2010
Designer
LS
1/8" = 1'-0"1 REFLECTED CEILING PLAN
ALIGN
AL
IG
N
4:
S
LO
PE
4:
S
LO
PE
4:
S
LO
PE
TO
M
AT
C H
EX
IS
TI
N
G
VE
R
IF
Y
VE
R
IF
Y
A7.02
A7.02
A7.02
A3.00
Sim
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
1/8" = 1'-0" A1.20
ROOF PLAN
DN
04.06.2010
Designer
LS
1/8" = 1'-0"1 ROOF PLAN
DNDN
TYP.
11"
3'
- 4
4' - 7" 1' - 0"1' - 11"
CL
R
2'
- 6
3"
3" 3"
MI
N.
, T
YP
3'
- 0
" C
LR
3"
3'
- 1
0"
2"
A4.00
A4.01
A7.00
NEW STEEL BOLLARD
5'
- 0
1/12 MAX SLOPE
19' - 0" (19" RISE)
1/1 2 M
AX
S
LO
PE
9'
- 0
9"
R
IS
E)
1/1 2 M
AX
S
LO
P E
AS
R
EQ
UI
RE
D
TO
R
EA
CH
G
RA
DE
9'
0" (9
" R
IS
E)
5'
- 0
7' - 0"
MIN., TYP.
3' - 0" CLR 1' - 0"
MIN., TYP.
3' - 0" CLR
COLUMN SUPPORT
FOR NEW ROOF
OVERHANG
5' - 0"
3' - 0" 4'
- 0
5' x 3' CONCRETE
STOOP AT BOTTOM
OF STAIRS. MATCH
TOP OF EXISTING
ADJACENT GRADE.
NEW GALVANIZED
STEEL GRATING AT
PORCH
GALVANIZED STEEL
GRATING AT RAMP
EXPANDED METAL
TREADS
A7.01
A3.00
5' x 3' CONCRETE
STOOP MATCH
TOP OF EXISTING
ADJACENT GRADE
D O
W N
D O
W N
DOWN
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
1/4" = 1'-0" A1.40
STAIR/RAMP PLANS
DN
04.06.2010
Designer
LS
1/4" = 1'-0"1 ENLARGED STAIR & RAMP PLAN
FINISH FLOOR
0"
GRADE
-3' - 0"
ROOF PLAN
9' - 7"
BOLLARD
WOOD COL, PER STRUCT, PAINT
TO MATCH EXISTING SIDING
SONOTUBE COLUMN SUPPORT,
EXPOSE 42" ABOVE GRADE
MINIMUM
NEW SIDING, BUILDING WRAP
ENTIRE WIDTH/HT THIS WALL
FINISH FLOOR
0"
GRADE
-3' - 0"
ROOF PLAN
9' - 7"
A7.02
NEW 72X48 (NOM)
FIXED/CASEMENT VINYL WINDOW
IN EXISTING ROUGH OPENING
REMOVE ENOUGH SIDING AROUND WINDOWS
TO INSTALL NEW WINDOW AND FLASHING AS
RECOMMENDED BY WINDOW AND SIDING
MANUFACTURER - REINSTALL EXISTING SIDING
AND WINDOW TRIM OR REPLACE WITH NEW AT
CONTRACTORS OPTION
A3.00
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
EGRESS WINDOWS4-30-20101
1/8" = 1'-0" A2.00
EXTERIOR ELEVATIONS
DN
04.06.2010
Designer
LS
1/8" = 1'-0"2 NORTH ELEVATION
1/8" = 1'-0"1 WEST ELEVATION
EXISTING
WEST
ELEVATION
EXISTING
ELEVATION
FINISH FLOOR
0"
GRADE
-3' - 0"
ROOF PLAN
9' - 7"
A4.00
A4.01
A7.02
TOILET
OPEN TO COVERED
PORCH BEYOND
A7.02
Sim
STRUCTURAL BEAM
INFILL AT EXISTING
NORTH WINDOWS
EXISTING EXTERIOR WALL - REPLACE OR
REPAIR ALL DAMAGED MATERIALS WHERE
EXISTING WINDOW WAS REMOVED
NEW PAINTED WOOD WINDOW CASING
NEW VINYL WINDOW WITH NAILING FLANGE
REMOVE ALL OLD FLASHING MEMBRANE AT WINDOW -
PROVIDE NEW WINDOW FLASHING MEMBRANE IN
WINDOW ROUGH OPENING - LAP NEW BUILDING
WRAP OVER WINDOW FLASHING MEMBRANE - TAPE
NAILING FLANGE TO MEMBRANE WITH MANUF.
RECOMMENDED TAPE
REMOVE ENOUGH SIDING TO INSTALL NEW
WINDOW AND FLASHING PER
MANUFACTURERS RECOMMENDATIONS
REPLACE EXISTING VINYL SIDING AT WINDOW OPENINGS
REPLACE EXISTING VINYL WINDOW TRIM
AT CONTRACTORS OPTION - NEW VINYL SIDING
AND WINDOW TRIM TO MATCH EXISTING MAY BE
PROVIDED- CONTRACTOR SHALL REPLACE
DAMAGED SIDING DUE TO REMOVAL
FIELD VERIFY ROUGH OPENING AND SIZE WINDOWS
IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS - SHIM AS REQUIRED
NEW VINYL WINDOW WITH NAILING FLANGE
REMOVE ALL OLD FLASHING MEMBRANE
AT WINDOW - PROVIDE NEW WINDOW
FLASHING MEMBRANE IN WINDOW ROUGH
OPENING - LAP NEW BUILDING WRAP
OVER WINDOW FLASHING MEMBRANE -
TAPE NAILING FLANGE TO MEMBRANE
WITH MANUF. RECOMMENDED TAPE
REPLACE EXISTING VINYL WINDOW TRIM
NEW PAINTED WOOD WINDOW
CASING AND SILL - CAULK
REPLACE EXISTING VINYL
SIDING AT WINDOW OPENINGS
EXISTING EXTERIOR WALL -
REPLACE OR REPAIR ALL
DAMAGED MATERIALS WHERE
EXISTING WINDOW WAS REMOVED
REMOVE ENOUGH SIDING TO
INSTALL NEW WINDOW AND
FLASHING PER MANUFACTURERS
RECOMMENDATIONS
EX
IS
TI
N
G R
O U
G H
O
PE
N
IN
G
SEALANT
SECTION IS
SHOWN AT
CASEMENT SASH
- FIXED SASH
SIMILAR
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
EGRESS WINDOWS4-30-20101
As indicated A3.00
BUILDING & WALL SECTIONS
DN
04.06.2010
Designer
LS
3/8" = 1'-0"1 PARTIAL BUILDING SECTION
1 1/2" = 1'-0"2 EGRESS WINDOWS
A4.00
A4.00
A4.00
A4.00
A4.01
GALVANIZED
STEEL RAMP
STRUCTURE
BEYOND
EXISTING
GRADE
GALVANIZED
STEEL STAIR
3/4" x 1 1/2" GALVANIZED METAL
BALUSTER
GALVANIZED STEEL CHANNEL
STRINGER
1 1/2" DEEP METAL GRATING, 1/2"
MAXIMUM OPENING IN DIRECTION
OF TRAVEL (EXPANDED METAL
TREADS AT STAIRS)
11 GA STEEL ANGLE
WOOD BEAM WHERE OCCURS
METAL FLASHING AT WOOD BEAM
1" x 1/2" GALVANIZED STEEL FLAT
BAR
1 1/2" x 3/4" GALVANIZED STEEL
FLAT BAR
3/4"
1 1/2" 1/2" x 3/4" GALVANIZED METAL
PICKET
1/2" x 3/4" GALVANIZED STEEL
FLAT BAR
1 1/2" X 3/4" GALVANIZED METAL
RAILING
1 1/2" DIAMETER GALVANIZED
METAL HANDRAIL
1/2" THICK PAINTED METAL
HANDRAIL BRACKET
1 3 /4"
3/4
1 1 /4"3/8"
1 1/2"
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
As indicated A4.00
STAIR/RAMP SECTIONS
DN
04.06.2010
Designer
LS
3/4" = 1'-0"3 STAIR SECTION
1 1/2" = 1'-0"2 STAIR DETAIL
1 1/2" = 1'-0"1 STAIR DETAIL
A4.01
A4.01
4 '- 0" MAX
EQUAL
4' - 0" MAX
EQUAL
3'
- 0
" A T
NO
SI
NG
3'
- 6
" A T
NO
SI
NG
1' - 11"
1' - 0"
3/4" x 1 1/2" GALVANIZED
METAL INTERMEDIATE
BALUSTER
3/4" x 1 1/2" GALVANIZED
METAL RAILING - PROVIDE
END CLOSURES AT ALL
OPEN ENDS
1 1/2" DIAMETER GALVANIZED
METAL HANDRAIL
1/2" x 3/4" GALVANIZED
METAL PICKET
3/4" x 1 1/2" GALVANIZED
METAL BALUSTER
3/4" x 1 1/2"
GALVANIZED
METAL
BALUSTER
4" CONC. STOOP
3' - 0"
EQ
EQ
EQ
EQ
EQ
GALVANIZED
STEEL PLATE
CONNECTOR
3'
- 0
1' - 0"
R 4"
COMPACTED NFS MATERIAL
2" DEEP STAIR TREAD WITH SAFETY
GRATING, 1/2" MAXIMUM OPENING
IN DIRECTION OF TRAVEL
GALVANIZED STEEL PLATE
GALVANIZED STEEL CHANNEL
STRINGER
1" x 1/2" GALVANIZED STEEL FLAT
BAR
1 1/2" x 3/4" GALVANIZED STEEL FLAT
BAR
4"4"
3/4" 1/2"
4" CONCRETE STOOP
3/4" x 1 1/2" GALVANIZED METAL
BALUSTER
1/2" x 3/4" GALVANIZED METAL
PICKET
7" M
AX
CL
11" 1/2" NOSINGS, TYP.
EXPANDED METAL TREADS, WITH
1/2" NOSINGS, TYP.
GALVANIZED STEEL PLATE
GALVANIZED STEEL CHANNEL
STRINGER
1" x 1/2" GALVANIZED STEEL FLAT
BAR
1 1/2" x 3/4" GALVANIZED STEEL
FLAT BAR
3/4" x 1 1/2" GALVANIZED METAL
BALUSTER
1/2" x 3/4" GALVANIZED METAL
PICKET
7" M
AX
4" 4" 4"CL CL
METAL GRATE, 1/2" MAX
OPENING IN BOTH DIRECTIONS
EXISTING JOIST TO REMAIN
NEW CONTINUOUS SHIM, ADD
METAL FLASHING OVER TOP OF
WOOD SHIM, SEE 3/A7.00
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
As indicated A4.01
STAIR/RAMP SECTIONS
DN
04.06.2010
Designer
LS
1" = 1'-0"3 STAIR SECTION
1 1/2" = 1'-0"2 STAIR DETAIL
1 1/2" = 1'-0"1 STAIR DETAIL
A 1
FLUSH
DOOR
A5.00
KICK PLATE,
BOTH SIDES AS
SCHEDULED10
FLOOR
5'
- 0
6"
ROOM SIGN
SEE NOTE 1
INTERIOR WALL ASSEMBLY,
AS INDICATED
HEADER PER STRUCTURAL
HOLLOW METAL FRAME AS
SCHEDULED, PAINT TYP.
DOOR AS SCHEDULED
1/2"
2"
SEALANT
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
As indicated A5.00
DOOR SCHEDULE
DN
04.06.2010
Designer
LS
DOOR AND FRAME SCHEDULE
NUMBER
DOORS FRAMES
FIRE
RATING
HARDWARE
GROUP REMARKSTYPE MATL FINISH
GLASS
TYPE
SIZE
TYPE MATL FINISHWIDTH HEIGHT
1 A SCW PT3 NA 36" 80" 1 HM PT3 B
2 A SCW PT3 NA 36" 80" 1 HM PT3 20 A
3 A SCW PT3 NA 36" 80" 1 HM PT3 20 A
4 A SCW PT3 NA 36" 80" 1 HM PT3 B
5 E E PT3 NA 36" 80" E E PT3 E RELOCATED DOOR ASSEMBLY
6 A SCW PT3 NA 36" 80" 1 HM PT3 C
1 1/2" = 1'-0"2 DOOR HEAD (JAMB SIM.)
DOOR & FRAME TYPES
"E" INDICATES EXISTING DOOR AND/OR FRAME
VERIFY EXISTING DOOR HEIGHT, NEW DOORS TO MATCH HEIGHT OF EXISTING DOORS
HARDWARE GROUPS: (ALL HARDWARE TO BE ADA ACCESSIBLE)
A - LEVER HANDLE, PRIVACY LATCH, 1 1/2" BUTT HINGE, CLOSER, DEAD BOLT, KICK PLATES, SMOKE SEAL
B - LEVER HANDLE, PRIVACY LATCH, 1 1/2" BUTT HINGE
C - PASSAGE SET, LEVER HANDLE, CLOSER, KICK PLATES
NOTES:
1. PROVIDE ROOM SIGNS AT EACH INTERIOR DOOR OR
CASED OPENING (BOTH EXISTING AND NEW). ALL ROOM
SIGNS TO INCLUDE ROOM NAME AND NUMBERS AS
PROVIDED BY THE OWNER. PROVIDE INTERNATIONAL
SYMBOLS OF ACCESSESIBILITY AT ALL TOILET ROOMS.
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
EGRESS WINDOWS4-30-20101
REVIEW COMMENTS5-12-20102
A5.20
ROOM FINISH SCHEDULE
LD
04.06.2010
Designer
LS
ROOM FINISH SCHEDULE
RM
NUM ROOM NAME FLOOR BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING COMMENTS
1 HALL LIN1 WDB PT1 PT1 PT1 PT1 SAT 1
2 TOILET RBR RB PT1 PT1 PT1 PT1 GWB-PT1 Prefab Fiberglass Shower Stall
3 BEDROOM LIN1 WDB EXIST PT2 PT2 EXIST SAT 3
4 BEDROOM LIN1 WDB PT2 PT2 EXIST EXIST SAT 3
5 TOILET RBR RB PT1 PT1 PT1 PT1 GWB-PT1 Prefab Fiberglass Shower Stall
6 KITCHEN EXIST/QT RB PT1 PT1 PT1 PT1 PT1 2
7 PANTRY EXIST EXIST PT1 PT1 PT1 PT1 PT1
8 ENTRY LIN1 WDB PT1 PT1 PT1 PT1 PT1
9 LAUNDRY ROOM LIN1 RB PT1 PT1 PT1 PT1 PT1
10 LOUNGE EXIST EXIST-PT3 EXIST EXIST EXIST EXIST EXIST SEE ADDITIVE BID ITEM 1
11 TV ROOM EXIST EXIST-PT3 EXIST/PLYWD EXIST EXIST EXIST/PLYWD EXIST SEE ADDITIVE BID ITEM 1
12 ENTRY LIN1 WDB EXIST EXIST EXIST EXIST EXIST/GWB-PT1
COLOR AND MATERIALS SCHEDULE
MARK MATERIAL STYLE/PRODUCT COLOR COMMENTS
LIN1 Linoleum Forbo Striato Sunset valley 5214 Sheet PT1 Paint 1 Sherwin Williams - Snow Bound 7004 Basic Wall and Ceiling Color PT2 Paint 2 Sherwin Williams - Lucent Yellow 6400 Accent Color PT3 Paint 3 Sherwin Williams - Jute Brown 6096 Door, Window and Frame Color QT Quarry Tile - Match Existing Color and Size 1.
RB Rubber Base Johnsonite - To Be Selected RBR Cork Rubber Flooring Expanko XRC Tile Sky Blue SAT Suspended Accoustical Tile Armstrong Dune-Angled Tegular 102800 White 2' x 4' SS1 Solid Surface 1 Corian Terra Collection Rice Paper Countertops WD1 Wood Cabinets Lanz Cabinets Natural on Alder WDB Wood Base - Paint Grade Wood Base 1 x 4 Paint PT3 Verify Size w/ exist. Wood Base
ROOM FINISH SCHEDULE COMMENTS
1. EXTEND NEW FLOORING AND BASE INTO MECH. CLOSET
2. EXISTING QT FLOOR TO REMAIN. INFILL EXPOSED AREAS WHERE CABINETS WERE REMOVED
W/ QT TO MATCH. REMOVE EXISTING TILES AT EDGE OF INFILL AS REQD TO INTEGRATE NEW FULL
TILES INTO ASHLAR PATTERN.
3. RE-INSTALL SALVAGED WINDOW TREATMENTS AFTER NEW CONSTRUCTION IS COMPLETE.
COLOR AND MATERIAL SCHEDULE COMMENTS
1. MATCH COLOR, SIZE AND THICKNESS OF EXISTING QUARRY TILE.
MATCH EXIST GROUT COLOR AS CLOSE AS POSSIBLE
ADDITIVE BID ITEM
1. PROVIDE NEW FLOORING, LIN-1 AT ROOMS 10 LOUNGE AND 11 TV ROOM.
1/2 " M
AX
EXISTING CMU WALL TO REMAIN
EXISTING FLOOR JOIST TO REMAIN
EXISTING 2x LEDGER TO REMAIN, REMOVE METAL FLASHING AT TOP OF 2x
NEW CONTINUOUS WOOD SHIM, ADD
METAL FLASHING OVER TOP OF WOOD
SHIM, SEE 3/A7.00
METAL GRATE, 1/2" MAX. OPENING IN BOTH
DIRECTIONS
EXISTING RIGID INSULATION TO REMAIN
EXISTING THRESHOLD TO REMAIN
EXISTING DOOR AND FRAME TO REMAIN
EXISTING PLYWOOD SHEATHING &
SUBFLOOR TO REMAIN - NEW FINISH AS
SCHEDULED
EXISTING WOOD BLOCKING TO REMAIN
A7.00
EXISTING FLOOR JOIST BEYOND TO REMAIN INTERIOR WALL ASSEMBLY,
AS INDICATED
EXISTING ACT CEILING, REPAIR
& REPLACE AS NECESSARY
5/8" GYPSUM BOARD TO WRAP OPENING
1'
- 0
NEW HEADER FRAMED
ACROSS OPENING, HEADER
PER STRUCTURAL
EXISTING GWB CEILING,
PATCH AND REPAIR AS
REQUIRED WITHIN WALL
RELOCATION
6"
ACT WALL ANGLE
NEW METAL GRATING
NEW 3/4" WOOD SHIM FULL LENGTH OF JOIST
EXISTING 2x WOOD FRAMING
WRAP EXISTING 2x FRAMING &
NEW SHIM WITH NEW
GALVANIZED METAL FLASHING
FINISH FLOOR
0"
3 1/4"
1/2" RUBBER
TRANSITION STRIP
COLOR TO MATCH
FLOOR TILE
3' - 2 1/4"
RUBBER FLOOR
TILE ON EXISTING
3/4" PLYWOOD
3/4
NEW ONE PIECE FIBERGLASS SHOWER UNIT
SHIM AS REQUIRED
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
1 1/2" = 1'-0" A7.00
DETAILS
DN
04.06.2010
Designer
LS
1 1/2" = 1'-0"1 PORCH DETAIL
1 1/2" = 1'-0"2 SOFFIT DETAIL
1 1/2" = 1'-0"3 PORCH DETAIL 1 1/2" = 1'-0"4 SHOWER DETAIL
NEW DOOR ASSEMBLY
AS INDICATED
NEW WALL ASSEMBLY
AS INDICATED
EXISTING WALL ASSEMBLY
AS INDICATED, PATCH AND
REPAIR AS NECESSARY
FEATHER NEW GWB INTO
EXISTING, TEXTURE AND
PAINT TO MATCH
EXISTING ROUGH WALL ASSEMBLY
EXISTING DOOR FRAMING
TO REMAIN
NEW 1x HARDWOOD TRIM, PAINTED
STUD WALL
SEE LEGEND FOR TYPE AND
DIMENSION
PAINTED WOOD INSIDE
CORNER TRIM
EXISTING PLYWD PANEL
SE
E
1/A 1.0
2'
0 7
/8"
FURR AROUND EXISTING
STEEL PIPE COLUMN
2'-10" MIN. CLEAR
STANDING SEAM METAL ROOFING
TO MATCH EXISTING, ON 15#
ROOFING FELT
PLYWOOD ROOF DECKING,
MATCH THICKNESS OF
EXISTING PLYWOOD
NEW 2x SISTER RAFTER ON EACH
SIDE OF EXISTING STRUCTURE
NEW 6x12 WOOD BEAM, PER
STRUCTURAL
PAINT ALL EXPOSED WOOD TO
MATCH EXISTING
NEW FASCIA BOARD PAINTED TO
MATCH EXISTING FASCIA
WOOD COLUMN PAINT TO MATCH
EXISTING SIDING, SEE
STRUCTURAL FOR MEMBER SIZE
CONCRETE PIER FOUNDATION
PROVIDE SMOOTH FINISH AND
CLEAR COAT W/ CONC. SEALER
AB
OV
E
GR
AD
E
3'
- 6
MATCH EXISTING OVERHANG
+/- 2' - 0"
SEE STRUCTURAL DRAWINGS
FOR CONCRETE BASE AND
WOOD COLUMN CONNECTION
DETAILS
NEW METAL FASCIA FLASHING TO
MATCH EXISTING
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
As indicated A7.01
DETAILS
Author
04.06.2010
Designer
Checker
1" = 1'-0"1 PLAN DETAIL
1" = 1'-0"2 PLAN DETAIL
1" = 1'-0"3 PLAN DETAIL
3/4" = 1'-0"4 CANOPY COLUMN
EXISTING FASCIA BOARD TO BE REMOVED
F.O. EXISTING RAFTER TO REMAIN
NEW 2x SISTER RAFTER ON EITHER SIDE
OF EXISTING STRUCTURE - EXTEND OVER
TOP OF EXISTING WALL
PLYWOOD, MATCH EXISTING THICKNESS
STANDING SEAM METAL ROOFING TO
MATCH EXISTING, ON 15# ROOFING FELT
SHEET METAL FLASHING TO MATCH
EXISTING ROOF
EXISTING 2x BLOCKING INFILLED WITH
RIGID INSULATION TO REMAIN
EXISTING STANDING SEAM METAL ROOF
TO REMAIN
EXISTING PLYWOOD SHEATHING TO
REMAIN
NEW 2x BLOCKING
TO F.O. EXIST. OVERHANG
2' - 0" VERIFY
12" MIN.
EXISTING RAFTER TO REMAIN
EXISTING RAFTER TO REMAIN, TYP.
NEW 2x SISTER RAFTER ON EACH SIDE
OF EXISTING STRUCTURE
PLYWOOD TO MATCH EXISTING THICKNESS
STANDING SEAM METAL ROOFING TO
MATCH EXISTING, ON 15# ROOFING FELT
SHEET METAL FLASHING TO MATCH
EXISTING ROOF
EXISTING 2x BLOCKING TO REMAIN
INFILLED WITH RIGID INSULATION
EXISTING STANDING SEAM METAL ROOF
TO REMAIN
EXISTING PLYWOOD SHEATHING TO
REMAIN
COVERED
PORCH
BUILDING
EXTERIOR
REMOVE EXIST. EAVE CAP & REPLACE
WITH NEW FLASHING & EAVE CAP
EXISTING WALL
CONSTRUCTION TO REMAIN
RIP 2x FRAMING TO FIT FLUSH w/ EXISTING SHEATHING
EXISTING WALL
CONSTRUCTION TO REMAIN
FEATHER NEW GWB
INTO EXISTING
NEW 6 MIL V.R.
SEAL TO WOOD FRAMING
4'
- 2
(E
R-21 BATT INSULATION
NEW 5/8" OSB EXTERIOR
GRADE SHEATHING
APPLY TO ENTIRE WALL
NEW SIDING TO MATCH
EXISTING
NEW 2x WOOD
SISTER RAFTERS
EXISTING 2x WOOD
ROOF FRAMING
MEMBER TO REMAIN
EXISTING EXTERIOR WALL
ASSEMBLY TO REMAIN
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
As indicated A7.02
DETAILS
DN
04.06.2010
Designer
LS
3/4" = 1'-0"1 ROOF DETAIL
3/4" = 1'-0"3 ROOF DETAIL
1 1/2" = 1'-0"5 WINDOW INFILL
1/2" = 1'-0"2 ROOF DETAIL
2' - 9" 2' - 9" 2' - 9" 3' - 0" 3' - 0"
1'
- 0
3'
- 6
2'
- 1
0" w/ mi cro co ord
12" DEEP WALL CABINETS W/ ADJ SHELVES
REINSTALL REFRIGERATORS
24" DEEP FULL HEIGHT
MICROWAVE CABINET
MICRO
MICROWAVE NIC
2'
- 0
2'
- 6
1' - 0" 2' - 6" 1' - 0" 2' - 0"
2'
- 1
0" w/ ra n g e co ord
CABINET DRAWER BASE
TO SUPPORT RANGE
SS1 COUNTER
& SPLASH
DROP-IN
RANGE
EXIST
VENT
SOFFIT
SWITCH FOR
E.F. / LIGHT
ABOVE STOVE
KNEE SPACE,
WITH
SHROUD
2'
- 0
2'
- 6
2' - 0" 2' - 6" 2' - 6"
FINISHED END
PANELS TO
MATCH
CABINETS.
FILLER
2' - 3"
CLEAR
2' - 0"3' - 0"
2'
- 1
0"
4' - 0"
PATCH AND
REPAIR WALLS
WHERE
EXISTING
RECEPTACLES
ARE REMOVED
KNEE
SPACE,
OPEN
PROVIDE
FINISHED END
PANELS, TO
MATCH
CABINETS
2'
- 6
2'
- 0
" DOWN-DRAFT
COOK TOP
OPEN TO
BEYOND
OPEN TO
BEYOND
BASE CABINET TO ACCOMMODATE VENT SYSTEM.
COORD. CABINET HEIGHT AND CONSTRUCTION
W/ COOK TOP. CONNECT TO EXIST. VENT SYSTEM
SOLID
SURFACE, SS1
COUNTERTOP
WOOD CASED
OPENING-PT3 REPAIR/
REPLACE TRIM
AROUND
OPENING AS
REQUIRED
A8.00
3'
- 6
2'
- 1
0"
EXISTING OPENING -
PATCH AND REPAIR
OPENING JAMBS
AND HEAD WHERE
DOOR WAS
REMOVED
NEW SOLID
SURFACE
COUNTERTOP
1' - 9"
KNEE SPACE
WITH FINISHED
END PANEL
BEYOND
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
3/8" = 1'-0" A8.00
INTERIOR ELEVATIONS
JD
04.06.2010
Designer
LS
3/8" = 1'-0"4 KITCHEN - NORTH
3/8" = 1'-0"2 KITCHEN - EAST
3/8" = 1'-0"3 KITCHEN - SOUTH
3/8" = 1'-0"1 KITCHEN - WEST
DW
3/8" = 1'-0"5 BAR COUNTER
18" X 36"
MIRROR/
SHELF UNIT
BOBRICK B292
SURFACE
MOUNTED
SOAP
DISPENSER
TOILET TISSUE
DISPENSER
BOBRICK B-7686
3'
- 0
2'
- 0
2'
- 1
0"
6'
- 4
3'
- 4
1' - 0"
42" GRAB BAR
36" GRAB BAR
BOBRICK B-5806
SERIES,TYP. PROVIDE
BLOCKING AS REQUIRED
3'
- 0
6"
TOWEL BAR,
BOBRICK B-7874
PROVIDE
BLOCKING IN
WALL AS
REQUIRED
2' - 0"2' - 0"
4'
- 0
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
1/4" = 1'-0" A8.01
INTERIOR ELELVATIONS
JD
04.06.2010
Designer
LS
1/4" = 1'-0"4 TOILET 5 N (TLT 2 S)
1/4" = 1'-0"1 TOILET 5 E (TLT 2 W)
1/4" = 1'-0"2 TOILET 5 S (TLT 2 N)
1/4" = 1'-0"3 TOILET 5 W (TOILET 2 E)
1/4" = 1'-0"7 PANTRY - EAST
1/4" = 1'-0"5 PANTRY - WEST
REINSTALLED
SHELVING
PAINTED GWB, PT1
EXIST QUARRY
TILE BASE TO
REMAIN
NEW CASED OPENING, PT3
PAINTED GWB, PT1
EXIST QUARRY
TILE BASE TO
REMAIN
EXISTING
SHELVING
PAINTED GWB, PT1
EXIST QUARRY
TILE BASE TO
REMAIN
1/4" = 1'-0"6 PANTRY - SOUTH
R-10
FOREST SERVICE
ALASKA REGION
U.S. DEPARTMENT OF AGRICULTURE
R
EP
D
GAT FONEMTR
A
R U
E
I LUC
T
# DATE DRAWN
DATE
SHEET NO.
SHEET TITLE
DESIGN
REVIEWED
REVISION
SCALE
CHUGACH NATIONAL FOREST
CORDOVA RANGER DISTRICT
FOREST
CWC 12 PERSON BUNKHOUSE
ACCESSIBILITY RETROFIT
PROJECT NAME
EGRESS WINDOWS4-30-20101
1/4" = 1'-0" A8.02
INTERIOR ELEVATIONS
DN
04.06.2010
Designer
LS
1/4" = 1'-0"2 BDRM 3 WEST (BDRM 4 WEST-SIM/REV)
1/4" = 1'-0"5 BDRM 3 EAST (BDRM 4 EAST-REV)
1/4" = 1'-0"3 BDRM 3 NORTH (BDRM 4 SOUTH-SIM/REV)
1/4" = 1'-0"6 BDRM 3 SOUTH (BDRM 4 NORTH REV)
NEW WINDOW TRIM AT
NEW WINDOWS
WOOD TRIM, PT3
WOOD BASE, PT3
PAINTED EXISTING
GWB, PT2
WOOD BASE, PT3
RELOCATE CLOSET
UNITS
NEW PAINTED GWB,
PT1
WOOD BASE, PT3
PAINTED GWB, PT1
WOOD BASE, PT3
REINSTALL EXISTING MINI BLINDS
EXISTING WINDOW TO REMAIN
PATCH AND REPAIR
DRYWALL AS REQUIRED
AT NEW WINDOW INSTALL
File details come from the government source that posted it. Updated .