Addendum Two .pdf

PDF 365 KB Posted

Attached to
RFB-266-25 Maintenance Facility Renovation Madisonville KY
Solicitation number
RFB 785 2500000732 7
Issued by
Hardin County, Kentucky

About this file

This is Addendum Two to Invitation to Bid (RFB-266-25) issued by the Commonwealth of Kentucky Department for Facilities and Support Services, Division of Engineering and Contract Administration, for maintenance facility renovations at the Kentucky Transportation Cabinet facility in Madisonville, Kentucky (Hopkins County). The addendum modifies specifications and adds new specification sections to the project documents. Specific changes include replacing subsection 2.3 of specification 10 51 13 (Metal Lockers) to designate Republic Storage Company standard lockers as the basis-of-design product with comparable alternatives from ArtMetal Products, DeBourgh Manufacturing, List Industries, Lyon Workspace Products, Penco Products, and Scranton Products. The addendum adds two new specification sections: 08 56 53 (Sliding Service Windows), which specifies C.R. Laurence DW Series Manual Deluxe Sliding Service Windows with comparable products from DK Hardware, Knape & Vogt, and Nissen & Company; and 10 21 13.19 (Plastic Toilet Compartments), which designates Scranton Products "Hiny Hiders" as the basis-of-design product with comparable alternatives including Accurate Partitions, Ampco by AJW, General Partitions Manufacturing, Global Partitions, and Marlite.

The addendum specifies detailed technical requirements for the new products, including material specifications, construction standards, hardware configurations, and installation procedures. Sliding service windows must feature two glazed panels with one fixed and one horizontally sliding panel, overhead tracking, 6063-T5 aluminum framing, tempered glass glazing, and a stainless steel shelf. Plastic toilet compartments must be constructed of solid high-density polyethylene with a minimum thickness of one inch, include stainless steel hardware and brackets, and comply with NFPA 286 fire performance standards and 2010 ADA accessibility requirements. The document references a Lynn Imaging addendum for any additional additions, deletions, or changes to specifications and drawings. The Engineering File Number is 609-C940-Z001-A78, and the C/S Project Number is 2418.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF KENTUCKY

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

INVITATION TO BID NO: RFB-266-25

FOR: Maintenance Facility Renovations Kentucky Transportation Cabinet Madisonville, Kentucky

DATE: June 16, 2025

RFB-785-2500000732

ADDENDUM NO. Two (2)

BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING

UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.

Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.

END OF ADDENDUM

Invitation to Bid No. RFB-266-25 For: Maintenance Facility Renovations Kentucky Transportation Cabinet

Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration

KYTC Maintenance Facility D-2 Hopkins County Madisonville, KY

Engineering File No. 609-C940-Z001-A78 C/S Project No. 2418

Addendum No. 2 June 13, 2025

The following Addendum Items shall be made part of the Contract Documents for this Project.

SPECIFICATIONS

1) Item #1

Refer to specification 10 51 13 - Metal Lockers. Replace the language under subsection 2.3 in it's entirety with the following language:

A. Basis-of-Design Product: Subject to compliance with requirements, provide Standard

Lockers by Republic Storage Company or comparable product by one of the following:

1. ArtMetal Products.

2. DeBourgh Mfg. Co.

3. List Industries.

4. Lyon Workspace Products.

5. Penco Products.

6. Scranton Products.

2) Item #2

Specification section 08 56 53 – Sliding Service Windows has been added.

3) Item #3

Specification section 10 21 13.19 - Plastic Toilet Compartments has been added.

END OF ADDENDUM

Project # 609-C940-Z001-A78

SLIDING SERVICE WINDOWS 08 56 53 - 1

SECTION 08 56 53 - SLIDING SERVICE WINDOWS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Factory-assembled sliding service windows.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

B. Shop Drawings: For windows.

1. Include plans, elevations, sections, and attachments to other work.

2. Hardware for sliding window units.

1.3 FIELD CONDITIONS

A. Field Measurements: Verify actual dimensions of openings by field measurements before fabrication.

PART 2 - PRODUCTS

2.1 SLIDING SERVICE WINDOWS

A. Basis-of-Design Product: Subject to compliance with requirements, provide C. R.

Laurence, DW Series, Manual Deluxe Sliding Service Window, catalog number DW1800A or comparable product by one of the following:

1. DK Hardware.

2. Knape & Vogt.

3. Nissen & Company.

B. Configuration: Two glazed panels, one fixed and one that slides horizontally. Sliding panel shall be the left-hand panel, from the clerk side. Track is overhead to provide smooth counter surface. Replacement and servicing of glass shall be from the clerk side of the window by means of an access panel in the top header and shall not require the removal of the frame from the opening.

C. Framing: Fabricated with 6063-T5 aluminum extrusions.:

http://www.specagent.com/LookUp/?ulid=58&mf=04&src=wd

SLIDING SERVICE WINDOWS 08 56 53 - 2

D. Sliding Window Hardware: Top-hung, heavy duty ball bearing slides. Provide manufacturer's standard self-latching handle for horizontal-sliding glazed panel.

E. Glazing and Glazing Materials: Glazing to be ¼ inch (6 mm) tempered glass. Comply with requirements in Section 08 80 00 "Glazing."

F. Accessories:

1. Stainless steel shelf, 12 inches deep, minimum 1 inch high.

G. Finish: Clear Anodic Finish: AAMA 611, AA-M12C22A41, Class I, 0.018 mm or thicker.

2.2 FABRICATION

A. General: Fabricate windows in a complete, assembled system for installation at project site.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of windows.

3.2 INSTALLATION

A. Fastening to In-Place Construction: Provide anchorage devices and fasteners where necessary for securing windows to in-place construction. Include threaded fasteners for inserts, and other connectors.

B. Install window in accordance with manufacturer’s written instructions and recommendations. Repair damaged units as directed (if approved by Architect) or replace with new units.

3.3 CLEANING AND PROTECTION

A. Clean surfaces promptly after installation of windows. Take care to avoid damaging the finish. Remove excess glazing and sealant compounds, dirt, and other substances.

1. Lubricate sliding window hardware.

END OF SECTION 08 56 53

PLASTIC TOILET COMPARTMENTS 10 21 13.19 - 1

SECTION 10 21 13.19 - PLASTIC TOILET COMPARTMENTS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Solid-plastic toilet compartments configured as toilet enclosures and urinal screens.

B. Related Requirements:

1. Section 06 10 53 "Miscellaneous Rough Carpentry" for blocking.

2. Section 10 28 00 "Toilet, Bath, and Laundry Accessories" for accessories mounted on toilet compartments.

1.2 COORDINATION

A. Coordinate requirements for blocking, reinforcing, and other supports concealed within wall.

1.3 ACTION SUBMITTALS

A. Product Data:

1. Solid-plastic toilet compartments:

a. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for toilet compartments.

B. Shop Drawings: For solid-plastic toilet compartments.

1. Include plans, elevations, sections, details, and attachment details.

2. Show locations of cutouts for compartment-mounted toilet accessories.

3. Show locations of centerlines of toilet fixtures.

4. Show locations of floor drains.

C. Samples for Initial Selection: Manufacturer's standard color sheets, showing full range of available colors for each type of toilet compartment material indicated.

1. Include Samples of hardware and accessories involving material and color selection.

D. Samples for Verification: Actual sample of finished products for each type of toilet compartment indicated.

PLASTIC TOILET COMPARTMENTS 10 21 13.19 - 2

1. Size: Manufacturers? standard size.

2. Include each type of hardware and accessory.

E. Product Schedule: For toilet compartments, prepared by or under the supervision of supplier, detailing location and selected colors for toilet compartment material.

1.4 INFORMATIONAL SUBMITTALS

A. Certificates:

1. Product Certificates: For each type of toilet compartment by manufacturer.

1.5 CLOSEOUT SUBMITTALS

A. Maintenance Data: For toilet compartments.

1.6 FIELD CONDITIONS

A. Field Measurements: Verify actual locations of toilet fixtures, walls, columns, ceilings, and other construction contiguous with toilet compartments by field measurements, and coordinate before fabrication.

PART 2 - PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. Fire Performance: Tested in accordance with, and pass the acceptance criteria of, NFPA 286.

B. Regulatory Requirements: Comply with applicable provisions in the U.S. Department of Justice "2010 ADA Standards for Accessible Design" and ICC A117.1.

2.2 SOLID-PLASTIC TOILET COMPARTMENTS

A. Basis-of-Design Product: Subject to compliance with requirements, provide Scranton Products; “Hiny Hiders” or a comparable product by one of the following:

1. Accurate Partitions Corp., an ASI Group Company.

2. Ampco by AJW.

3. General Partitions Mfg. Corp.

4. Global Partitions Corp., an ASI Group Company.

5. Marlite.

B. Toilet-Enclosure Style: Overhead braced, Floor anchored.

http://www.specagent.com/Lookup?ulid=9486 http://www.specagent.com/Lookup?uid=123457132263 http://www.specagent.com/Lookup?uid=123457132263 http://www.specagent.com/Lookup?uid=123457132251 http://www.specagent.com/Lookup?uid=123457132254 http://www.specagent.com/Lookup?uid=123457132256 http://www.specagent.com/Lookup?uid=123457132257 http://www.specagent.com/Lookup?uid=123457132260

PLASTIC TOILET COMPARTMENTS 10 21 13.19 - 3

C. Urinal-Screen Style: Wall hung.

D. Door, Panel, and Pilaster Construction: Solid, high-density polyethylene (HDPE) panel material, not less than 1 inch thick, seamless, with eased edges, and with homogenous color and pattern throughout thickness of material.

1. Integral Hinges: Configure doors and pilasters to receive integral hinges.

2. Heat-Sink Strip: Manufacturer's standard continuous, extruded-aluminum or stainless steel strip fastened to exposed bottom edges of solid-plastic components to hinder malicious combustion.

E. Color and Pattern: One color and pattern in each room as selected by Architect from manufacturer's full range of “Traditional” and “Bold” color collections.

F. Pilaster Shoes and Sleeves (Caps): Manufacturer's standard design; stainless steel.

G. Brackets (Fittings):

1. Full-Height (Continuous) Type: Manufacturer's standard design; stainless steel.

2.3 HARDWARE AND ACCESSORIES

A. Hardware and Accessories, Heavy Duty: Manufacturer's heavy-duty operating hardware and accessories.

1. Hinges: Manufacturer's minimum 0.062-inch-thick stainless steel continuous, cam type that swings to a closed or partially open position, allowing emergency access by lifting door. Mount with through bolts.

2. Latch and Keeper: Manufacturer's heavy-duty, surface-mounted, cast-stainless steel latch unit, designed to resist damage due to slamming, with combination rubber-faced door strike and keeper, and with provision for emergency access.

Provide units that comply with regulatory requirements for accessibility at compartments designated as accessible. Mount with through bolts.

3. Coat Hook: Manufacturer's heavy-duty combination cast-stainless steel hook and rubber-tipped bumper, sized to prevent inswinging door from hitting compartment-mounted accessories. Mount with through bolts.

4. Door Bumper: Manufacturer's heavy-duty, rubber-tipped, cast-stainless steel bumper at outswinging doors. Mount with through bolts.

5. Door Pull: Manufacturer's heavy-duty, cast-stainless steel pull at outswinging doors that complies with regulatory requirements for accessibility. Provide units on both sides of doors at compartments designated as accessible. Mount with through bolts.

B. Overhead Bracing: Manufacturer's standard continuous, extruded-aluminum head rail with antigrip profile and in manufacturer's standard finish.

C. Anchorages and Fasteners: Manufacturer's standard exposed fasteners of stainless steel, finished to match the items they are securing, with theft-resistant-type heads.

Provide sex-type bolts for through-bolt applications. For concealed anchors, use

PLASTIC TOILET COMPARTMENTS 10 21 13.19 - 4

stainless steel, hot-dip galvanized steel, or other rust-resistant, protective-coated steel compatible with related materials.

2.4 MATERIALS

A. Aluminum Castings: ASTM B26/B26M.

B. Aluminum Extrusions: ASTM B221.

C. Stainless Steel Sheet: ASTM A240/A240M or ASTM A666, Type 304, stretcher-leveled standard of flatness.

D. Stainless Steel Castings: ASTM A743/A743M.

E. Zamac: ASTM B86, commercial zinc-alloy die castings.

2.5 FABRICATION

A. Fabrication, General: Fabricate toilet compartment components to sizes indicated.

Coordinate requirements and provide cutouts for through-partition toilet accessories where required for attachment of toilet accessories.

B. Overhead-Braced Units: Provide manufacturer's standard corrosion-resistant supports, leveling mechanism, and anchors at pilasters to suit floor conditions. Provide shoes at pilasters to conceal supports and leveling mechanism.

C. Floor-Anchored Units: Provide manufacturer's standard corrosion-resistant anchoring assemblies with leveling adjustment nuts at pilasters for structural connection to floor.

Provide shoes at pilasters to conceal anchorage.

D. Door Size and Swings: Unless otherwise indicated, provide 24-inch-wide, inswinging doors for standard toilet compartments and 36-inch-wide, outswinging doors with a minimum 32-inch-wide, clear opening for compartments designated as accessible.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine areas and conditions, with Installer present, for compliance with requirements for fastening, support, alignment, operating clearances, and other conditions affecting performance of the Work.

1. Confirm location and adequacy of blocking and supports required for installation.

B. Proceed with installation only after unsatisfactory conditions have been corrected.

PLASTIC TOILET COMPARTMENTS 10 21 13.19 - 5

3.2 INSTALLATION OF PLASTIC TOILET COMPARTMENTS

A. General: Comply with manufacturer's written installation instructions. Install units rigid, straight, level, and plumb. Secure units in position with manufacturer's recommended anchoring devices.

1. Maximum Clearances:

a. Pilasters and Panels: 1/2 inch.

b. Panels and Walls: 1 inch.

2. Full-Height (Continuous) Brackets: Secure panels to walls and to pilasters with full-height brackets.

a. Locate bracket fasteners, so holes for wall anchors occur in masonry or tile joints.

b. Align brackets at pilasters with brackets at walls.

B. Overhead-Braced Units: Secure pilasters to floor and level, plumb, and tighten. Set pilasters with anchors penetrating not less than 1-3/4 inches into structural floor unless otherwise indicated in manufacturer's written instructions. Secure continuous head rail to each pilaster with no fewer than two fasteners. Hang doors to align tops of doors with tops of panels and adjust, so tops of doors are parallel with overhead brace when doors are in closed position.

C. Floor-Anchored Units: Set pilasters with anchors penetrating not less than 2 inches into structural floor unless otherwise indicated in manufacturer's written instructions. Level, plumb, and tighten pilasters. Hang doors and adjust, so tops of doors are level with tops of pilasters when doors are in closed position.

D. Urinal Screens: Attach with anchoring devices to suit supporting structure. Set units level and plumb, rigid, and secured to resist lateral impact.

3.3 ADJUSTING

A. Hardware Adjustment: Adjust and lubricate hardware according to hardware manufacturer's written instructions for proper operation. Set hinges on inswinging doors to hold doors open approximately 30 degrees from closed position when unlatched. Set hinges on outswinging doors to return doors to fully closed position.

END OF SECTION 10 21 13.19

Project # 609-C93Y-Z001-A78

TABLE OF CONTENTS 00 20 00 - 1

TABLE OF CONTENTS

DIVISION 00 - PROCUREMENT AND CONTRACT REQUIREMENTS – BY OWNER

DIVISION 01 - GENERAL REQUIREMENTS

01 21 00 Special Conditions 01 23 00 Alternates 01 40 00 Quality Requirements

DIVISION 02 - EXISTING CONDITIONS – NOT USED

DIVISION 03 – CONCRETE

03 30 00 Cast-In-Place Concrete

DIVISION 04 – MASONRY – NOT USED

DIVISION 05 – METALS

05 50 00 Metal Fabrications

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

06 10 53 Miscellaneous Rough Carpentry 06 64 00 Plastic Paneling

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 21 00 Thermal Insulation 07 21 30 Metal Building Insulation 07 26 00 Vapor Retarder Facings 07 72 53 Snow Guards 07 92 00 Joint Sealants

DIVISION 08 – OPENINGS

08 11 13 Hollow Metal Doors and Frames 08 31 13 Access Doors and Frames 08 51 13 Aluminum Windows 08 56 53 Sliding Service Windows 08 71 00 Door Hardware 08 80 00 Glazing

DIVISION 09 – FINISHES

09 22 16 Non-structural Metal Framing 09 29 00 Gypsum Board 09 51 13 Acoustical Panel Ceilings 09 65 13 Resilient Base and Accessories 09 91 00 Painting

TABLE OF CONTENTS 00 20 00 - 2

DIVISION 10 – SPECIALTIES

10 11 00 Visual Display Units 10 14 23 Panel Signage 10 21 13.19 Plastic Toilet Compartments 10 28 00 Toilet and Bath Accessories 10 44 16 Fire Extinguishers 10 51 13 Metal Lockers 10 70 00 Aluminum Canopies

DIVISION 11 – EQUIPMENT

11 13 10 Manual Chain Hoists 11 31 00 Residential Appliances

DIVISION 12 – FURNISHINGS

12 35 30 Residential Casework 12 36 23 Plastic-laminate-clad Countertops 12 36 61 Solid Surfacing

DIVISION 13 – SPECIAL CONSTRUCTION

13 34 19 Metal Building Systems

DIVISION 22 – PLUMBING

22 00 00 General Provisions for Plumbing

22 05 00 Common Work Results for Plumbing 22 05 53 Identification for Plumbing Piping Equipment 22 07 00 Plumbing Insulation 22 11 13 Facility Water Distribution Piping 22 11 16 Domestic Water Piping 22 11 19 Domestic Water Piping Specialties 22 13 13 Facility Sanitary Sewers 22 13 16 Sanitary Waste and Vent Piping 22 13 19 Sanitary Waste Piping Specialties 22 15 13 General Service Compressed Air Piping 22 33 00 Electric, Domestic Water Heaters 22 40 00 Plumbing Fixtures 22 45 00 Emergency Plumbing Fixtures 22 47 00 Water Coolers

DIVISION 23 - HEATING VENTILATING AND AIR CONDITIONING

23 00 00 General Provisions for Mechanical 23 05 00 Common Work Results for Mechanical 23 05 53 Identification for Mechanical Piping and Equipment

TABLE OF CONTENTS 00 20 00 - 3

23 06 00 Testing, Adjusting, and Balancing for HVAC (KY-DFM) 23 07 00 Mechanical Insulation 23 11 23 Facility Natural Gas Piping 23 31 13 Metal Ducts 23 33 00 Air Duct Accessories 23 34 23 HVAC Power Ventilators 23 37 13 Diffusers and Grilles 23 37 16 Louvers and Vents 23 51 23 Gas Vents 23 55 33 Fuel- Fired Unit Heaters 23 74 13 Packaged, Outdoor, Central-Station Air-Conditioning Units

DIVISION 26 – ELECTRICAL

26 00 00 General Provisions for Electrical 26 05 00 Common Work Results for Electrical 26 05 19 Low-Voltage Electrical Power Conductors and Cables 26 05 26 Grounding and Bonding for Electrical Systems 26 05 29 Hangers and Supports for Electrical Systems 26 05 33 Raceway and Boxes for Electrical Systems 26 05 53 Identification for Electrical Systems 26 24 16 Panelboards 26 27 26 Wiring Devices 26 28 16 Enclosed Switches and Circuit Breakers 26 51 00 Interior Lighting

DIVISION 27 – COMMUNICATIONS- NOT USED

DIVISION 31 – EARTHWORK

31 10 00 Site Clearing 31 20 00 Earth Moving 31 20 10 Geotechnical Report 31 31 16 Termite Control

DIVISION 32 - EXTERIOR IMPROVEMENTS

32 12 16 Asphalt Paving 32 17 13 Parking Bumpers 32 17 23 Pavement Markings 32 92 00 Turf and Grasses

DIVISION 33 – UTILITIES

33 41 00 Storm Utility Drainage Piping

END OF TABLE OF CONTENTS

Addendum Two
Addendum Two (1)
08 56 53 - Sliding Service Windows
10 21 13.19 - Plastic Toilet Compartments
Project Manual Table of Contents (6)

File details come from the government source that posted it. Updated .