Addendum Six .pdf
PDF 7 MB Posted
- Solicitation number
- RFB 785 2500000732 7
- Issued by
- Hardin County, Kentucky
About this file
This Addendum Six document is issued by the Commonwealth of Kentucky Department for Facilities and Support Services, Division of Engineering and Contract Administration for Invitation to Bid No. RFB-266-25 regarding Maintenance Facility Renovations at the Kentucky Transportation Cabinet facility in Madisonville, Kentucky. The addendum modifies specifications and drawings for the project, including revisions to thermal insulation specifications (Section 07 21 00), non-structural metal framing specifications (Section 09 22 16) with updated stud and runner requirements at door jambs requiring minimum base-metal thickness of 0.060 inch per ASTM C 645, and structural drawing revisions to Sheets S101 (Details 5 and 6). Additionally, architectural drawings have been replaced in their entirety for Sheets D101, A101, A102, A103, and A104. The project involves interior renovations including new gypsum board assemblies over metal stud framing, suspension ceiling systems, window installations, metal canopy systems, locker installations, and various interior finishes throughout the facility's crew room, offices, toilet facilities, and maintenance bay areas. The addendum establishes binding changes to contract documents that bidders must incorporate into their proposals.
The addendum also addresses mechanical and electrical components, specifically requiring that lighting fixtures be furnished by the Owner and installed by the Contractor, with emergency battery packs supplied by the Contractor that must be compatible with the specified Skyline G4 Power Selectable Linear Highbay LED fixture. The fixture specifications include 120-277V (347-480V optional), 0-10V dimming capability, and advanced occupancy sensor and photocell controls with programmable operation modes. No pricing information, set-asides, incumbent contractor details, or funding sources are specified in this addendum document, which serves solely to clarify and modify the technical requirements and drawings for this renovation project at the KYTC Maintenance Facility in Hopkins County.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-266-25
FOR: Maintenance Facility Renovations Kentucky Transportation Cabinet Madisonville, Kentucky
DATE: July 3, 2025
RFB-785-2500000732
ADDENDUM NO. Six (6)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-266-25 For: Maintenance Facility Renovations Kentucky Transportation Cabinet
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
KYTC Maintenance Facility D-2 Hopkins County Madisonville, KY
Engineering File No. 609-C940-Z001-A78 C/S Project No. 2418
Addendum No. 6 July 03, 2025
The following Addendum Items shall be made part of the Contract Documents for this Project.
SPECIFICATIONS
1) Item #1 Refer to specification 07 21 00 – Thermal Insulation. This specification section has been revised in its entirety.
2) Item #2 Refer to specification 09 22 16 – Non-Structural Metal Framing. Add the language under subsection 2, note C, as defined below:
C. Studs and Runners (at door jambs): ASTM C 645.
1. Steel Studs and Runners:
a. Minimum Base-Metal Thickness: 0.060 inch.
b. Depth: As indicated on Drawings.
DRAWINGS
3) Item #1 Refer to Structural Drawings:
1. Sheet S101 – Details 5 and 6 have been revised for this addendum.
4) Item #2 Refer to Architectural Drawings:
1. Sheet D101 has been replaced in its entirety.
2. Sheet A101 has been replaced in its entirety.
3. Sheet A102 has been replaced in its entirety.
4. Sheet A103 has been replaced in its entirety.
5. Sheet A104 has been replaced in its entirety.
MECHANICAL and ELECTRICAL
6.01 Refer to Drawing E101 and attached Light Fixture Cut Sheet. The lighting fixture attached is the fixture to be furnished by the Owner and installed by the Contractor. The emergency battery pack to be furnished by the Contractor (referenced in Addendum 4.00) shall be compatible with fixture to be furnished.
Attachments:
1. Light Fixture Cut Sheet
END OF ADDENDUM
Project # 609-C940-Z001-A78
NON-STRUCTURAL METAL FRAMING 092216 - 1
SECTION 092216 - NON-STRUCTURAL METAL FRAMING
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Non-load-bearing steel framing systems for interior gypsum board assemblies.
2. Suspension systems for interior gypsum ceilings, soffits, and grid systems.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
PART 2 - PRODUCTS
2.1 FRAMING SYSTEMS
A. Framing Members, General: Comply with ASTM C 754 for conditions indicated.
1. Steel Sheet Components: Comply with ASTM C 645 requirements for metal unless otherwise indicated.
2. Protective Coating: ASTM A 653/A 653M, G60, hot-dip galvanized unless otherwise indicated.
B. Studs and Runners: ASTM C 645.
1. Steel Studs and Runners:
a. Minimum Base-Metal Thickness: 0.033 inch.
b. Depth: As indicated on Drawings.
C. Studs and Runners (at door jambs): ASTM C 645.
1. Steel Studs and Runners:
a. Minimum Base-Metal Thickness: 0.060 inch.
b. Depth: As indicated on Drawings.
D. Slip-Type Head Joints: Where indicated, provide one of the following:
1. Single Long-Leg Runner System: ASTM C 645 top runner with 2-inch-deep flanges in thickness not less than indicated for studs, installed with studs friction fit
NON-STRUCTURAL METAL FRAMING 092216 - 2
into top runner and with continuous bridging located within 12 inches of the top of studs to provide lateral bracing.
2. Double-Runner System: ASTM C 645 top runners, inside runner with 2-inch-deep flanges in thickness not less than indicated for studs and fastened to studs, and outer runner sized to friction fit inside runner.
3. Deflection Track: Steel sheet top runner manufactured to prevent cracking of finishes applied to interior partition framing resulting from deflection of structure above; in thickness not less than indicated for studs and in width to accommodate depth of studs.
E. Flat Strap and Backing Plate: Steel sheet for blocking and bracing in length and width indicated.
1. Minimum Base-Metal Thickness: 0.033 inch.
F. Cold-Rolled Channel Bridging: Steel, 0.053-inch minimum base-metal thickness, with minimum 1/2-inch-wide flanges.
1. Depth: 1-1/2 inches.
2. Clip Angle: Not less than 1-1/2 by 1-1/2 inches, 0.068-inch-thick, galvanized steel.
G. Hat-Shaped, Rigid Furring Channels: ASTM C 645.
1. Minimum Base-Metal Thickness: 0.033 inch.
2. Depth: 7/8 inch unless noted otherwise.
H. Cold-Rolled Furring Channels: 0.053-inch uncoated-steel thickness, with minimum 1/2-inch-wide flanges.
1. Depth: 3/4 inch.
2. Furring Brackets: Adjustable, corrugated-edge type of steel sheet with minimum uncoated-steel thickness of 0.033 inch.
3. Tie Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.062-inch-diameter wire, or double strand of 0.048-inch-diameter wire.
I. Z-Shaped Furring: With slotted or non-slotted web, face flange of 1-1/4 inches, wall attachment flange of 7/8 inch, minimum uncoated-metal thickness of 0.018 inch, and depth required to fit insulation thickness indicated.
2.2 SUSPENSION SYSTEMS
A. Tie Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.062-inch-diameter wire, or double strand of 0.048-inch-diameter wire.
B. Wire Hangers: ASTM A 641/A 641M, Class 1 zinc coating, soft temper, 0.16 inch in diameter.
C. Flat Hangers: Steel sheet, 1 by 3/16 inch by length indicated.
NON-STRUCTURAL METAL FRAMING 092216 - 3
D. Carrying Channels: Cold-rolled, commercial-steel sheet with a base-metal thickness of
0.053 inch and minimum 1/2-inch-wide flanges.
1. Depth: 1-1/2 inches.
E. Furring Channels (Furring Members):
1. Cold-Rolled Channels: 0.053-inch uncoated-steel thickness, with minimum 1/2-inch-wide flanges, 3/4 inch deep.
2. Steel Studs and Runners: ASTM C 645.
a. Minimum Base-Metal Thickness: 0.033 inch.
b. Depth: As indicated on Drawings.
3. Hat-Shaped, Rigid Furring Channels: ASTM C 645, 7/8 inch deep.
a. Minimum Base-Metal Thickness: 0.033 inch.
F. Grid Suspension System for Gypsum Board Ceilings: ASTM C 645, direct-hung system composed of main beams and cross-furring members that interlock.
1. Products: Subject to compliance with requirements, provide one of the following:
a. Armstrong World Industries, Inc.; Drywall Grid Systems.
b. Chicago Metallic Corporation; Drywall Grid System.
c. USG Corporation; Drywall Suspension System.
2.3 AUXILIARY MATERIALS
A. General: Provide auxiliary materials that comply with referenced installation standards.
1. Fasteners for Metal Framing: Of type, material, size, corrosion resistance, holding power, and other properties required to fasten steel members to substrates.
B. Isolation Strip at Exterior Walls: Provide one of the following:
1. Asphalt-Saturated Organic Felt: ASTM D 226, Type I (No. 15 asphalt felt), nonperforated.
2. Foam Gasket: Adhesive-backed, closed-cell vinyl foam strips that allow fastener penetration without foam displacement, 1/8 inch thick, in width to suit steel stud size.
http://www.specagent.com/LookUp/?ulid=228&mf=04&mf=95&src=wd&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123456814688&mf=04&&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123456814689&mf=04&&mf=04&src=wd http://www.specagent.com/LookUp/?uid=123456814690&mf=04&&mf=04&src=wd
NON-STRUCTURAL METAL FRAMING 092216 - 4
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine areas and substrates, with Installer present, and including welded hollow-metal frames, cast-in anchors, and structural framing, for compliance with requirements and other conditions affecting performance of the Work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Suspended Assemblies: Coordinate installation of suspension systems with installation of overhead structure to ensure that inserts and other provisions for anchorages to building structure have been installed to receive hangers at spacing required to support the Work and that hangers will develop their full strength.
1. Furnish concrete inserts and other devices indicated to other trades for installation in advance of time needed for coordination and construction.
3.3 INSTALLATION, GENERAL
A. Installation Standard: ASTM C 754.
1. Gypsum Board Assemblies: Also comply with requirements in ASTM C 840 that apply to framing installation.
B. Install supplementary framing, and blocking to support fixtures, equipment services, heavy trim, grab bars, toilet accessories, furnishings, wall-mounted TV brackets or similar construction. See Drawings for all locations.
C. Install bracing at terminations in assemblies.
D. Do not bridge building control and expansion joints with non-load-bearing steel framing members. Frame both sides of joints independently.
3.4 INSTALLING FRAMED ASSEMBLIES
A. Install framing system components according to spacings indicated, but not greater than spacings required by referenced installation standards for assembly types.
1. Single-Layer Application: 16 inches o.c. unless otherwise indicated.
2. Tile Backing Panels: 16 inches o.c. unless otherwise indicated.
B. Where studs are installed directly against exterior masonry walls or dissimilar metals at exterior walls, install isolation strip between studs and exterior wall.
NON-STRUCTURAL METAL FRAMING 092216 - 5
C. Install studs so flanges within framing system point in same direction.
D. Install tracks (runners) at floors and overhead supports. Extend framing full height to structural supports or substrates above suspended ceilings except where partitions are indicated to terminate at suspended ceilings. Continue framing around ducts penetrating partitions above ceiling.
1. Slip-Type Head Joints: Where framing extends to overhead structural supports, install to produce joints at tops of framing systems that prevent axial loading of finished assemblies.
2. Door Openings: Screw vertical studs at jambs to jamb anchor clips on door frames;
install runner track section (for cripple studs) at head and secure to jamb studs.
a. Install two studs at each jamb unless otherwise indicated.
b. Install cripple studs at head adjacent to each jamb stud, with a minimum 1/2-inch clearance from jamb stud to allow for installation of control joint in finished assembly.
c. Extend jamb studs through suspended ceilings and attach to underside of overhead structure.
3. Other Framed Openings: Frame openings other than door openings the same as required for door openings unless otherwise indicated. Install framing below sills of openings to match framing required above door heads.
E. Direct Furring:
1. Screw to wood framing.
2. Attach to concrete or masonry with stub nails, screws designed for masonry attachment, or powder-driven fasteners spaced 24 inches o.c.
F. Installation Tolerance: Install each framing member so fastening surfaces vary not more than 1/8 inch from the plane formed by faces of adjacent framing.
3.5 INSTALLING SUSPENSION SYSTEMS
A. Install suspension system components according to spacings indicated, but not greater than spacings required by referenced installation standards for assembly types.
1. Hangers: 48 inches o.c.
2. Carrying Channels (Main Runners): 48 inches o.c.
3. Furring Channels (Furring Members): 16 inches o.c.
B. Isolate suspension systems from building structure where they abut or are penetrated by building structure to prevent transfer of loading imposed by structural movement.
C. Suspend hangers from building structure as follows:
1. Install hangers plumb and free from contact with insulation or other objects within ceiling plenum that are not part of supporting structural or suspension system.
NON-STRUCTURAL METAL FRAMING 092216 - 6
a. Splay hangers only where required to miss obstructions and offset resulting horizontal forces by bracing, countersplaying, or other equally effective means.
2. Where width of ducts and other construction within ceiling plenum produces hanger spacings that interfere with locations of hangers required to support standard suspension system members, install supplemental suspension members and hangers in the form of trapezes or equivalent devices.
a. Size supplemental suspension members and hangers to support ceiling loads within performance limits established by referenced installation standards.
3. Wire Hangers: Secure by looping and wire tying, either directly to structures or to inserts, eye screws, or other devices and fasteners that are secure and appropriate for substrate, and in a manner that will not cause hangers to deteriorate or otherwise fail.
4. Flat Hangers: Secure to structure, including intermediate framing members, by attaching to inserts, eye screws, or other devices and fasteners that are secure and appropriate for structure and hanger, and in a manner that will not cause hangers to deteriorate or otherwise fail.
5. Do not attach hangers to permanent metal forms. Furnish cast-in-place hanger inserts that extend through forms.
6. Do not connect or suspend steel framing from ducts, pipes, or conduit.
D. Seismic Bracing: Sway-brace suspension systems with hangers used for support.
E. Grid Suspension Systems: Attach perimeter wall track or angle where grid suspension systems meet vertical surfaces. Mechanically join main beam and cross-furring members to each other and butt-cut to fit into wall track.
F. Installation Tolerances: Install suspension systems that are level to within 1/8 inch in 12 feet measured lengthwise on each member that will receive finishes and transversely between parallel members that will receive finishes.
END OF SECTION 09 22 16
A
B
3 4 5 6 7 8
C
D
E
F
G
S101
NEW CANOPY
RE: ARCH'L
PROVIDE ATTACHMENT SUPPORT PER TYPICAL
DETAIL AT EACH ANCHOR LOCATION
NEW CANOPY
RE: ARCH'L
PROVIDE ATTACHMENT SUPPORT PER TYPICAL
DETAIL AT EACH ANCHOR LOCATION
NEW CANOPY
RE: ARCH'L
PROVIDE ATTACHMENT SUPPORT PER TYPICAL
DETAIL AT EACH ANCHOR LOCATION
NEW CANOPY
RE: ARCH'L
PROVIDE ATTACHMENT SUPPORT PER TYPICAL
DETAIL AT EACH ANCHOR LOCATION
NEW CANOPY
RE: ARCH'L
PROVIDE ATTACHMENT SUPPORT PER TYPICAL
DETAIL AT EACH ANCHOR LOCATION
NEW CANOPY
RE: ARCH'L
PROVIDE ATTACHMENT SUPPORT PER TYPICAL
DETAIL AT EACH ANCHOR LOCATION
NEW CANOPY
RE: ARCH'L
PROVIDE ATTACHMENT SUPPORT PER TYPICAL
DETAIL AT EACH ANCHOR LOCATION
S101
S101
S101
NEW TRENCH DRAIN
RE: TYP. DETAIL
EXISTING TRENCH DRAIN
S101
C1
COLUMN & MARK
RE: SCHEDULE
WALL FOOTING
STEM WALL
SLAB EDGE
1'-0"
WALL FOOTING STEP & MARK
DIMENSION REPRESENTS STEP HEIGHT "D"
RE: TYP. STEPPED FOOTING DETAIL
HX
STRUCTURAL WALL
RE: WALL TYPE SCHEDULE
PILASTER
RE: PLAN NOTES & WALL SCHEDULE
WALL OPENING
NEW METAL HEADER IN EXISTING WALL
WALL TYPE MARK
RE: SCHEDULE
P1 F1
PIER & MARK
RE: SCHEDULE
FOUNDATION & MARK
RE: SCHEDULE
GENERAL PLAN LEGEND
RE: SCHEDULE
LAP SPLICE
EXISTING CONCRETE
TRENCH DRAIN
EXISTING TRENCH DRAIN
REINFORCEMENT
DRILL & EPOXY REBAR
WITH HIT-HY 200
ADHESIVE
NEW TRENCH DRAIN
RE: TYP. DETAIL FOR
SIZE & REINFORCEMENT
EMBED
9" MIN
1' - 0" 5"
#3 BAR AT 12" O.C.
NEW SLAB-ON-GRADE
RE: PLAN NOTES
EXISTING SLAB-ON-GRADE
DRILL AND EPOXY REBAR
INTO EXISTING SLAB WITH
HIT-HY 200 ADHESIVE. CENTER
REBAR IN SLABS.
FIN. FLOOR
EL. = FIELD VERIFY
T H
IC
K
N E
S S
M A
T C
H . E
X
IS
T
IN
G
MATERIAL SPECIFICATIONS
COLD-FORMED METAL FRAMING:
ASTM A1003, STRUCTURAL GRADE, TYPE H, METALLIC COATED
#4 BENT BARS
@ 12" O.C. MAX.
CONT. #4 @ 12"
O.C. MAX.
6"
TRENCH DRAIN
RE: MEP
SLAB-ON-GRADE TO
MATCH EXISTING
4" 4"
1' - 0" (TYP. OPP. SIDE)
S101
4 S101
FIN. FLOOR
EL. = FIELD VERIFY
FIRST
EL. 100' - 0"
2 3 4 5 6
EXISTING MECH LOUVER
RE: MEP & ARCH'L
EXISTING DOOR
NEW WINDOW
RE: ARCH'L
NEW DOOR CANOPY AT
EXISTING DOOR (TYP.)
RE: ARCH'L
800S200-97 (TYP. EACH WINDOW JAMB).
ATTACH C-STUDS TO EXISTING GIRT ABOVE W/ 12 GA. CLIP
ANGLE & (2) 5/8" ⌀ GALV. BOLTS PER LEG.
ATTACH BASE OF C-STUD W/ GALV. 12 GA. CLIP ANGLE AND
FASTENERS SPECIFIED BELOW:
• (2) 5/8" ⌀ GALV. BOLTS IN VERT. LEG TO C-STUD
• (2) 5/8" ⌀ X 4" HILTI KWIK HUS-EZ SCREW ANCHORS IN
HORIZ. LEG TO CONCRETE BELOW
800S200-97 (TYP. EACH WINDOW SILL).
ATTACH HORIZ. C-STUDS AT EACH END
TO VERT. C-STUDS W/ 12 GA. CLIP ANGLE
& (2) 5/8" ⌀ GALV. BOLTS PER LEG
EXISTING WALL GIRT (TYP.)
25'-0"25'-0"25'-0"25'-0"
S101
TYP.
800S200-97 (TYP. EACH WINDOW JAMB).
ATTACH C-STUDS TO EXISTING GIRTS ABOVE AND BELOW
W/ 12 GA. CLIP ANGLE & (2) 5/8" ⌀ GALV. BOLTS PER LEG.
800S200-97 (TYP. EACH WINDOW HEADER
AND SILL).
ATTACH HORIZ. C-STUDS AT EACH END
TO VERT. C-STUDS W/ 12 GA. CLIP ANGLE
& (2) 5/8" ⌀ GALV. BOLTS PER LEG
EXISTING WALL GIRT TO BE CUT FOR NEW
WINDOW INSTALLATION (TYP.).
ATTACH CUT ENDS OF GIRT TO NEW
WINDOW JAMB W/ 12 GA. CLIP ANGLE & (2)
5/8" ⌀ GALV. BOLTS PER LEG.
NEW HIGH BAY WINDOW.
TYP. (2) LOCATIONS THIS WALL, (4)
LOCATIONS OPPOSITE WALL.
SEE ARCH'L FOR WINDOW LOCATIONS.
CANOPY BY OTHERS
RE: ARCH'L
SUPPORT CABLE / STRUT
FOR CANOPY FRAMING BY
OTHERS
TURNBUCKLE BY CANOPY MFR.THRU-BOLT WITH
COMPRESSION SLEEVE BY
CANOPY MFR.
THRU-BOLT WITH
COMPRESSION SLEEVE BY
CANOPY MFR.
BOT. OF CANOPY
RE: ARCH'L
GALLV. HSS6x4x1/4 (TYP. EACH
CANOPY CABLE LOCATION).
ATTACH TUBE TO EXISTING
GIRTS ABOVE AND BELOW W/
(2) 12 GA. CLIP ANGLES EACH
END & (2) 5/8" ⌀ GALV. BOLTS,
PER ANGLE LEG
EXISTING WALL GIRT.
EXACT SPACING TO BE FIELD
VERIFIED
EXISTING MAN DOOR
RE: ARCH'L
W/ ARCH'L
8" VERIFY
CONCRETE CURB.
FACE OF CURB TO ALIGN
WITH SHOP SIDE OF WALL.
VERIFY W/ ARCH'L
8"
STUD WALL
RE: ARCH'L
#4 DOWEL @ 12" O.C., ROUGHLY
CENTERED (+/- 1") IN CONCRETE
CURB. DRILL & EPOXY 6" INTO
EXISTING CONCRETE SLAB USING
HILTI HIT-HY 200 OR APPROVED
EQUAL.
#5 CONT. BAR
V E
R
IF
Y 8"
F
IE
LD
FIN. FLOOR
EL. = FIELD VERIFY
EXISTING SLAB ON GRADE
CONT. SIKA GREENSTREAK
PVC RETROFIT
WATERSTOP MODEL #655
W/ S.S. EPOXY ANCHOR,
OR APPROVED EQUAL
VERIFY W/ ARCH'L
2'-1"
CONCRETE CURB.
RE: ARCH'L FOR
PLACEMENT
8"
STUD WALL
RE: ARCH'L
(3) #4 DOWEL @ 12" O.C., ROUGHLY
EQUALLY SPACED (+/- 1") IN
CONCRETE CURB. DRILL & EPOXY 6"
INTO EXISTING CONCRETE SLAB
USING HILTI HIT-HY 200 OR
APPROVED EQUAL.
(3) #5 CONT. BAR
V E
R
IF
Y 8"
F
IE
LD
FIN. FLOOR
EL. = FIELD VERIFY
EXISTING SLAB ON GRADE
1'-6"
LOCKERS
RE: ARCH'L
CONT. SIKA GREENSTREAK
PVC RETROFIT
WATERSTOP MODEL #655
W/ S.S. EPOXY ANCHOR,
OR APPROVED EQUAL
Paducah, KY Office
2301 McCracken Blvd, Paducah, KY 42001
270.443.1995 / BFWengineers.com
WWW.CLOTFELTER-SAMOKAR.COM
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605
AS-BUILT DATE
DECA LOG #
DESCRIPTION OF REVISIONS DATE
DESCRIPTION OF REVISIONS DATE
DRAWING INFORMATION
A & E FILE NO.
DRAWING DATE
DRAWN BY
CHECKED BY
PHASE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
ACCOUNT NO.
RTA DATE
/2
/2
:1 :3
A
M
609-C940-Z001-A78JAH
BFW-25001
3/28/2025
DRL
FOUNDATION PLAN
S101
RTA
KYTC MAINTENANCE FACILITY
MADISONVILLE, KENTUCKY
3/28/2025
1/8" = 1'-0"
FOUNDATION PLAN
TYPICAL DETAIL3
NEW TRENCH DRAIN TO EXISTING TRENCH DRAIN
TYPICAL DETAIL4
NEW TO EXISTING SLAB-ON-GRADE CONNECTING DETAIL
TYPICAL DETAIL2
TRENCH DRAIN CONSTRUCTION
SCALE: 3/16" = 1'-0"
1 BUILDING ELEVATION (GRID G)
TYPICAL DETAIL7
CANOPY ATTACHMENT SUPPORT
TYPICAL DETAIL5
CONCRETE CURB AT BASE OF STUD WALLS
TYPICAL DETAIL6
CONCRETE CURB AT BASE OF LOCKERS
ADDENDUM - 05 7-03-2025
BradleyABeatty Rectangle
BradleyABeatty Text Box
25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"
25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"
MAINT. BAY
2 2
EXISTING WORK
TO REMAIN
1. ALL WORK SHALL BE EXECUTED TO
SUBSTANTIALLY COMPLY WITH THE CURRENT
APPLICABLE KENTUCKY BUILDING CODES AND
OTHER APPLICABLE STATE AND LOCAL CODES
HAVING JURISDICTION OVER THIS PROJECT,
I.E., NATIONAL ELECTRICAL CODE, AND BOCA
MECHANICAL CODE.
2. ITEMS UNCLEAR AS TO THE DESIGN INTENT OR
APPLICATION SHALL BE BROUGHT TO THE
OWNER'S ATTENTION PRIOR TO BID FOR
WRITTEN CLARIFICATION.
GENERAL NOTES
A
R C H I T E
C
T
D A
V
I D
M. SAM
O K
A R
K
E N T U C K
Y
REG ISTERED
OF
NO.
COMMONWEALTH
WWW.CLOTFELTER-SAMOKAR.COM
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605
AS-BUILT DATE
DECA LOG #
DESCRIPTION OF REVISIONS DATE
DESCRIPTION OF REVISIONS DATE
DRAWING INFORMATION
A & E FILE NO.
DRAWN BY
CHECKED BY
PHASE
RTA DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
ACCOUNT NO.
DRAWING DATE
KYTC MAINTENANCE FACILITY MADISONVILLE, KENTUCKY
/2
/2
:3 :5
P
M
DMS
03/27/25
AHH
DEMOLITION FLOOR PLAN
D101
C
609-C940-Z001-A78
03/28/25
SCALE: 1/8" = 1'-0"
DEMOLITION FLOOR PLAN
SHEET NOTES
1 EXISTING WALLS TO BE DEMOLISHED.
2 PORTION OF EXISTING WALL TO BE DEMOLISHED.
3 EXISTING EYE WASH STATION TO BE DEMOLISHED.
ADDENDUM 5 07/03/25
BradleyABeatty Rectangle
BradleyABeatty
A104
A102
CREW ROOM
SHOWER
ADA TOILET
FEMALE
TOILET
MECH. RM.
MAINT. BAY
25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"
25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"
T
O O
U T
S
ID
E F
A C
E O
F E
X
IS
T 'G
G
IR
T
S
F
IE
L D
V E
R
IF
Y
A L
IG
N
W
IT
H D
O O
R J
A M
B S
A104
ALIGN CENTERLINE WITH JAMB
2'-0" 2'-0"
18'-0" 60'-0" +/- TRENCH DRAIN
40'-0"
6'-0"
/8
OFFICE
OFFICE
OFFICE
EXISTING SPRINKLER DRAIN DOWN - TO REMAIN
TOILET
IC
E
A104
A104
2 2
MTL LINER PANEL
16'-8 3/4"
MTL LINER PANEL
13'-8 5/8"
MTL LINER PANEL
30'-0 3/4"
FRP
8'-0"
M T
L L
IN
E
R P
A N
E L
ALL SIDES
4 7/8" FRP
ALL SIDES
4 7/8" FRP
A101
PROVIDE METAL LINER
PANEL OUTSIDE CORNER
TRIM FULL HEIGHT OF LINER.
1. ALL WORK SHALL BE EXECUTED TO
SUBSTANTIALLY COMPLY WITH THE CURRENT
APPLICABLE KENTUCKY BUILDING CODES AND
OTHER APPLICABLE STATE AND LOCAL CODES
HAVING JURISDICTION OVER THIS PROJECT,
I.E., NATIONAL ELECTRICAL CODE, AND BOCA
MECHANICAL CODE.
2. ITEMS UNCLEAR AS TO THE DESIGN INTENT OR
APPLICATION SHALL BE BROUGHT TO THE
OWNER'S ATTENTION PRIOR TO BID FOR
WRITTEN CLARIFICATION.
GENERAL NOTES
NOTE:
- ALL CEILING SUPPORTS SHALL BE 14 GA, 8"
- PROVIDE RIM TRACK WHERE REQUIRED BY MANF.
- COORDINATE CEILING SUPPORT LAYOUT WITH CEILING GRID
A
R C H I T E
C
T
D A
V
I D
M. SAM
O K
A R
K
E N T U C K
Y
REG ISTERED
OF
NO.
COMMONWEALTH
WWW.CLOTFELTER-SAMOKAR.COM
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605
AS-BUILT DATE
DECA LOG #
DESCRIPTION OF REVISIONS DATE
DESCRIPTION OF REVISIONS DATE
DRAWING INFORMATION
A & E FILE NO.
DRAWN BY
CHECKED BY
PHASE
RTA DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
ACCOUNT NO.
DRAWING DATE
KYTC MAINTENANCE FACILITY MADISONVILLE, KENTUCKY
/2
/2
:3 :5
P
M
DMS
03/27/25
AHH
BUILDING FLOOR PLAN
A101
C
609-C940-Z001-A78
03/28/25
SCALE: 1/8" = 1'-0"
BUILDING FLOOR PLAN
SHEET NOTES
1 EXISTING DUCTWORK TO BE INSULATED - REFER TO
MECHANICAL DRAWINGS.
2 NEW EXTERIOR HOSE BIB - REFER TO PLUMBING
DRAWINGS.
3 NEW INTERIOR HOSE BIB - REFER TO PLUMBING
DRAWINGS.
4 NEW TRENCH DRAIN EXTENSION - REFER TO
PLUMBING DRAWINGS.
5 NEW ALUMINUM CANOPY SYSTEM. PROVIDE FOR
BLOCKING WITHIN EXISTING WALL FRAME, PATCH
AND REPAIR EXISTING INTERIOR BUILDING WALL
FINISH/INSULATION SYSTEM AS REQUIRED TO
COMPLETE WORK. TYPICAL WHERE INDICATED.
N
ADDENDUM 3 06/18/25
ADDENDUM 5 07/03/25
SCALE: 1/8" = 1'-0"
CEILING SUPPORT PLAN
BradleyABeatty Rectangle
BradleyABeatty
A104
E1
MECH. RM.
CREW ROOM
SHOWER
ADA TOILET
FEMALE
TOILET
/4
/8
/8
WT-1
WT-2
WT-2
WT-3
WT-3
WT-3
/4
WT-1
TOILET
OFFICE
OFFICE
OFFICE
07 08 09
WT-1
WT-3
CORRIDOR
WT-2
WT-2
A102
1 1 1
/8
/8
/4
8"
3 3/4"
3'-4" 13'-2 5/8" 3 5/8" 30'-2" 3 5/8" 17'-2 3/4" 3'-4" 5 1/2" 8"
11'-0" 3 5/8" 11'-0" 3 5/8" 11'-0" 3 5/8" 6'-0 7/8" 8"
/8
/4
/8
7'-3 3/8" 3'-4" 7'-3 3/8" 3'-4" 7'-3 3/8" 3'-4"
/8
WT-3
A102
A102
A102 6
A103
H
B
A
A104
/4 "3
/8
/8
WT-1
A A
WT-2
IC
E
3 5/8" 6'-0 5/8"
3 3
5 5 5
(30) S.T. LOCKERS
30'-0"
7 7 7
8 8 8
' T
B
WT-1
A104
A103
G
WT-1
WT-1
17'-6 1/8"
EXISTING
EXISTING
EXISTING
EXISTING
A104
1. ALL WORK SHALL BE EXECUTED TO
SUBSTANTIALLY COMPLY WITH THE CURRENT
APPLICABLE KENTUCKY BUILDING CODES AND
OTHER APPLICABLE STATE AND LOCAL CODES
HAVING JURISDICTION OVER THIS PROJECT,
I.E., NATIONAL ELECTRICAL CODE, AND BOCA
MECHANICAL CODE.
2. ITEMS UNCLEAR AS TO THE DESIGN INTENT OR
APPLICATION SHALL BE BROUGHT TO THE
OWNER'S ATTENTION PRIOR TO BID FOR
WRITTEN CLARIFICATION.
GENERAL NOTES
VARIES
2" SEE SCH. 2"
H.M. FRAME
F HG
8"
8"
NV
8"6"
S E
E S
C H
E D
U L E
S E
E S
C H
E D
U L E
S E
E S
C H
E D
U L E
TYPE A
7"W X 7"H
Office
Women
NOTE: ALL SIGNAGE
SHALL BE INSTALLED
5'-0" ABOVE FINISHED
FLOOR ELEVATION TO
CENTER LINE OF SIGN.
TYPE B
7"W X 9"H
PEMB METAL
WALL PANEL
THERMAL BLOCK
@ EACH WALL
GIRT
PEMB WALL GIRT
@ 8'-0"+/- A.F.F.
5/8" GYP. BD.
OVER 3 5/8" MTL.
STUDS @ 16" O.C.
10'-0" A.F.F.
CEILING SYSTEM
T.O. GYP. BD.
PEMB
THERMAL
INSULATION
SYSTEM
UNFACED SOUND
BATT
5/8" GYP. EACH SIDE OVER MTL.
STUD FRAMING @ 16" O.C. SEE
PLAN FOR PARTITION DEPTHS
PROVIDE SLIDE CLIPS AT
WALL BRACING LOCATIONS
METAL STUD PARTION
BRACING
CEILING SYSTEM
10'-0" A.F.F.
T.O. GYP. BD.
UNFACED SOUND BATT
WT-1 WT-3
CEILING
SYSTEM
SOUND BATT
EXTEND STUDS AND
SOUND BATT UP TO
ROOF STRUCTURE,
PROVIDE SLIP TYPE
HEAD TRACK FOR
DEFLECTION
10'-0" A.F.F.
T.O. GYP. BD.
WT-2
VAPOR
RETARDER
5/8" GYP. BD.
NOTE: DOUBLE 3 5/8" MTL. STUD PARTITIONS
SHALL BE FLUSH WITH EACH FACE OF
CONCRETE GRADE BEAM, STUDS IN EACH
PARTITION SHALL ALIGN ACROSS FULL DEPTH
OF WALL, AND STUD SPACING @ 16" O.C.
COORDINATE WITH FLOOR PLAN AND RELATED
DETAILS FOR VARIOUS SHEATHING TYPES AND
LOCATIONS ALONG THIS WALL. PARTITIONS
SHALL EXTEND UP TO ROOF STRUCTURE WITH
SLIP TYPE HEAD TRACK FOR DEFLECTION
CONTRACTORS OPTION: USE 8" METAL STUDS
@ 16" O.C. IN LIEU OF DOUBLE 3 5/8" STUDS.
5/8" GYP. BD.
OVER 7/8" MTL.
HAT CHANNEL
FURRING @ 16"
O.C. VERTICAL
MTL. STUD
PARTITIONS
6 4
37" 37" 28" 29"
CL CL CL
3'-0"3'-0"
TOILET
2 2
A102
A103
H
BASE
A103
H
"4
PLASTIC PANELING
FILLER
24"30"18"33"18"36"
SOFFIT: PAINTED GYP. BD. ON MTL. STUD FRAMING
PRE-FIN.
SIDE PANEL
FILLER
FILLER24" (BC)30" RANGE18" (BC)33" (BC)18" (BC)36" REF.
24" D. W/DR RACKS
42" PANTRY UNITFILLER
RANGE
HOODP. LAMINATE COUNTERTOP
AND SPLASHES SIDE SPLASH
VINYL BASE
"1
/2
A103
H
ELEC.
WATER
COOLERBASE, SEE ROOM
FINISH SCHEDULE
T.O. CURB
FRP
FASTNED TO
5/8" GYP. ON
METAL
FRAMING
S.A.T. CEILING
SYSTEM
PANTRY
WALL
OPENING
SOFFIT, 5/8" GYP. BD.
OVER MTL. STUDS @
16" O.C.
4'-0" 1'-0"
A
R C H I T E
C
T
D A
V
I D
M. SAM
O K
A R
K
E N T U C K
Y
REG ISTERED
OF
NO.
COMMONWEALTH
WWW.CLOTFELTER-SAMOKAR.COM
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605
AS-BUILT DATE
DECA LOG #
DESCRIPTION OF REVISIONS DATE
DESCRIPTION OF REVISIONS DATE
DRAWING INFORMATION
A & E FILE NO.
DRAWN BY
CHECKED BY
PHASE
RTA DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
ACCOUNT NO.
DRAWING DATE
KYTC MAINTENANCE FACILITY MADISONVILLE, KENTUCKY
/2
/2
:3 :5
P
M
DMS
03/27/25
AHH
ENLARGED PLANS / INTERIOR ELEVATIONS
A102
C
609-C940-Z001-A78
03/28/25
SCALE:A102 1/4" = 1'-0"
ENLARGED FLOOR PLAN2
TOILET ACCESSORY SCHEDULE
TYPE
MARK DESCRIPTION COMMENTS
1 VERTICAL GRAB BAR 18" x 1 -1/4" O.D. SEE ELEVATION FOR HEIGHTS
2 GRAB BAR 42" x 1 1/4" O.D. SEE ELEVATION FOR HEIGHTS
3 MIRROR, 18" x 36" SEE ELEVATION FOR HEIGHTS
4 PAPER TOWEL DISPENSER N.I.C. - OWNER PROVIDED / CONTRACTOR INSTALLED
5 TOILET PAPER DISPENSER N.I.C. - OWNER PROVIDED / CONTRACTOR INSTALLED
6 SOAP DISPENSER N.I.C. - OWNER PROVIDED / CONTRACTOR INSTALLED
SHEET NOTES
1 PERIMETER STUD WALL, PROVIDE 5/8" GYPSUM
BOARD OVER 3 5/8" METAL STUD FRAMING WITH
UNFACED SOUND BATTS FULL HEIGHT OF STUDS,
STUDS SHALL ANCHOR TO WALL GIRTS AND EXTEND
UP TO 10'-0" ABOVE FINISH FLOOR ELEVATION
UNLESS NOTED OTHERWISE.
2 COLUMN FURRING, PROVIDE 5/8" GYPSUM BOARD
OVER 3 5/8" METAL STUD FRAMING WITH UNFACED
SOUND BATTS FULL HEIGHT OF STUDS, STUDS
SHALL ANCHOR TO RIGID FRAME MEMBERS AND
EXTEND UP TO 10'-0" ABOVE FINISH FLOOR
ELEVATION. FIELD VERIFY REQUIRED DIMENSIONS.
ALIGN FACE OF STUDS WITH CONCRETE PIER,
EXTEND GYPSUM BOARD TO THE FLOOR.
3 20 LB FIRE EXTINGUISHER ON WALL BRACKET.
4 10 LB FIRE EXTINGUISHER ON WALL BRACKET.
5 PROVIDE STEEL SECURITY GRILL AT EACH
LOCATION FOR WINDOW TYPE "A", SEE DETAIL ON
SHEET A102.
6 ELECTRIC WATER COOLER. SPOUT HEIGHT AT 42"
A.F.F. PROVIDE WATER BOTTLE FILLING STATION.
7 PROVIDE GYPSUM BOARD EXPANSION JOINT AT
COLUMN GRID.
8 PROVIDE SOLID SURFACE WINDOW SILL AND APRON
FOR WINDOW TYPE "A", COORDINATE WITH WINDOW
DETAILS ON SHEET A103.
9 PATCH EXISTING GYPSUM BOARD WALL TO MATCH
ADJACENT WALL FINISH.
10 EXISTING WATER COOLER WITH ATTACHED CANE
APRON PROVIDES 27" HEIGHT REQUIRED FROM
FINISH FLOOR PER SECTION 1003.3, 2018 KBC
SCALE: 1/4" = 1'-0"
DOOR / FRAME ELEVATIONS
SCALE: 1 1/2" = 1'-0"
INTERIOR SIGNAGE
ROOM FINISH SCHEDULE
NO. ROOM NAME FLOOR FINISH BASE WALLS WAINSCOT CEILING CLG HT REMARKS NO.
101 CREW ROOM EPOXY 6" VINYL LATEX N/A S.A.T. 9'-0" 101
102 FEMALE TOILET EPOXY 6" VINYL (EXISTING TO REMAIN) N/A (EXISTING TO REMAIN) 9'-0" NO WORK THIS AREA 102
103 ADA TOILET EPOXY 6" VINYL (EXISTING TO REMAIN) N/A (EXISTING TO REMAIN) 9'-0" NO WORK THIS AREA 103
104 SHOWER EPOXY 6" VINYL (EXISTING TO REMAIN) N/A (EXISTING TO REMAIN) 9'-0" NO WORK THIS AREA 104
106 MAINT. BAY SEALED CONCRETE SEALED CONCRETE N/A EXPOSED STRUCT. VARIES NO WORK THIS AREA 106
107 OFFICE EPOXY 6" VINYL LATEX N/A S.A.T. 9'-0" 107
108 OFFICE EPOXY 6" VINYL LATEX N/A S.A.T. 9'-0" 108
109 OFFICE EPOXY 6" VINYL LATEX N/A S.A.T. 9'-0" 109
110 TOILET EPOXY 6" VINYL PLASTIC PANEL N/A S.A.T. 9'-0" 110
111 CORRIDOR EPOXY 6" VINYL LATEX N/A S.A.T. 9'-0" 111
DOOR SCHEDULE
DR. # DRS. PER FRAME
DOOR FRAME
HDW
SET SIGN COMMENTS
DR.
#W. H. TH. TYPE MAT. GLASS TYPE MAT. DEPTH
HD.
/JMB. SILL
01 1 3'-0" 7'-0" 1 3/4" NV H.M. GL-2 1 H.M. 10 5/8" B/A103 B/A103 7 ----- 01
06 1 3'-0" 7'-0" 1 3/4" NV H.M. GL-2 1 H.M. 10 5/8" B/A103 B/A103 7 ----- 06
07 1 3'-0" 7'-0" 1 3/4" F H.M. GL-2 1 H.M. 6" C/A103 C/A103 2 A SIGN TEXT : OFFICE 07
08 1 3'-0" 7'-0" 1 3/4" F H.M. GL-2 1 H.M. 6" C/A103 C/A103 2 A SIGN TEXT : OFFICE 08
09 1 3'-0" 7'-0" 1 3/4" F H.M. GL-2 1 H.M. 6" C/A103 C/A103 2 A SIGN TEXT : OFFICE 09
10 1 3'-0" 7'-0" 1 3/4" F H.M. GL-2 1 H.M. 6" C/A103 C/A103 4 B SIGN TEXT : MEN 10
11 1 3'-0" 7'-0" 1 3/4" NV H.M. GL-2 1 H.M. 10 5/8" B/A103 B/A103 7 ----- 11
12 1 3'-0" 7'-0" 1 3/4" HG H.M. GL-2 1 H.M. 5 3/4" A/A103 A/A103 1 ----- 12
SCALE: 3/4" = 1'-0"
WALL TYPE LEGEND
SCALE: 3/8" = 1'-0"
TOILET PLANS
SCALE:
ELEVATION
A102 3/8" = 1'-0"
SCALE:
ELEVATION
A102 3/8" = 1'-0"
SCALE:
ELEVATION
A102 3/8" = 1'-0"
ADDENDUM 5 07/03/25
BradleyABeatty Rectangle
BradleyABeatty
FIXED
ALUMINUM WINDOW
INSULATED GLASS
TYPE GL-2
SEC. 085113
D
A103
A
W
IN
D O
W S
IL
L
E
E
V
D
A103
D
A103
3'-0"
SLIDING SERVICE
WINDOW TEMPERED
GLASS TYPE GL-1
SEC. 085653
E
A103
B
W
IN
D O
W S
E
V
E
A103
E
A103
3'-0" 4'-0"
W
IN
D O
W S
E
V
FIXED
ALUMINUM WINDOW
INSULATED GLASS
TYPE GL-2
SEC. 085113
F
A103
F
A103
F
A103
C
1/2" x 3/4" STEEL FLAT
BAR STOCK
STRAP: 1/2" x 2" STEEL
FLAT BAR STOCK
ELEVATION
PLAN
WINDOW TYPE "A"
PEMB PRE-FINISHED
JAMB TRIM
PEMB PRE-FINISHED HEAD
TRIM
SECTION
C L E
A R
O U
T T
O O
U T
O F
F L A
T B
A R
C L E
A R
F
IE
L D
V E
R
IF
Y
W
IN
D O
W
"A
R O
U G
H O
P E
N
IN
G
3'-0" +/- WINDOW "A" ROUGH OPENING
STRAP: 1/2" x 2"
STEEL FLAT BAR
STOCK
EQ. EQ.
2"
3/4"
4"
3/4"
4"
3/4"
4"
3/4"
4"
3/4"
EQ. 2"
3/4"
4"
3/4"
4"
3/4"
4"
3/4"
4"
3/4"
EQ.
TAMPER PROOF THRU-BOLT
TO PEMB JAMB FRAME, 1 BOLT
AT EA. END OF STRAPS
1/2" 2"
TAMPER PROOF
THRU-BOLT
1/2" x 3/4" STEEL
FLAT BAR STOCK
STRAP: 1/2" x 2" STEEL
FLAT BAR STOCK
ALIGN EXT. FACE OF STRAP W/
EXT FACE OF FRAMED OPENING
ALUM. WINDOW UNIT "A"
CAULK EACH SIDE, CONT.
3"+/- 3 1/4" 5 5/8"
/4
STEEL SECURITY GRILL
ALIGN W/ JAMB FRAME
ALUM. WINDOW UNIT "A"
STEEL SECURITY GRILL
SILL EXTENSION BY
WINDOW SUPPLIER
ALIGN W/ JAMB FRAME 3"+/- 3 1/4" 7 1/4"
5/8" GYP. BD. OVER 3 5/8"
MTL. STUD FURRING @
16" O.C.
UNFACED SOUND BATT
5/8" GYP. BD. JAMB
CLOSURE
SOLID SURFACE
WINDOW STOOL
CONT. CLEAR SEALANT
AROUND PERIMETER
1"
5/8" GYP. BD. OVER 3 5/8"
MTL. STUD FURRING @
16" O.C.
UNFACED SOUND BATT
SOLID SURFACE WINDOW
STOOL OVER 1/2" SUB-SILL
5/8" GYP. BD. JAMB
CLOSURE
SOLID SURFACE
APRON
CONT. CLEAR SEALANT
AROUND PERIMETER
STEEL SECURITY GRILL
ALUM. WINDOW UNIT "A"
PANEL CLOSURE STRIP
SILL EXTENSION BY
WINDOW SUPPLIER
HEAD
JAMB
SILL
EXIST'G. METAL
WALL PANEL
EXIST'G. PEMB WALL GIRT
PROVIDE TRIM AT
HEAD AND JAMB AT
NEW OPENING
5/8" GYP. BD. OVER 3 5/8"
MTL. STUDS @ 16" O.C.
PROVIDE FRAMING AT
NEW OPENING
EXIST'G. PEMB INSUL.
FILL GIRT CAVITY W/
BATT INSULATION
UNFACED SOUND BATT
INSULATION FACING
5/8" GYP. BD. SOFFIT
PANEL CLOSURE STRIP
EXIST'G. METAL
WALL PANEL
EXIST'G. PEMB INSUL.
FILL GIRT CAVITY W/
BATT INSULATION
PROVIDE JAMB TRIM
EXIST'G. METAL
WALL PANEL
EXIST'G. PEMB INSUL.
PROVIDE FRAMING AT
NEW OPENING
PROVIDE SILL FRAMING
AT NEW OPENING
HEAD
JAMB
SILL
5/8" GYP. BD. OVER MTL.
STUDS @ 16" O.C.
MTL. STUD SYSTEM
HEADER FRAMING
5/8" GYP. BD. OVER MTL.
STUDS @ 16" O.C.
SLIDING SERVICE
WINDOW "B"
1x3 PAINTED
WOOD APRON
CONT. CLEAR SEALANT
AROUND PERIMETER
SLIDING SERVICE
WINDOW "B"
STAINLESS STEEL
WINDOW SILL
5/8" GYP. BD.
OVER MTL.
STUDS @ 16" O.C.
UNFACED SOUND
BATT
UNFACED SOUND BATT
2x WD. BLOCKING
CAULK PERIMETER
BOTH SIDES
ALUM. HEAD FRAME
2x WD. BLOCKING
SLIDING SERVICE
WINDOW "B"
STAINLESS STEEL
WINDOW SILL
12"
4"
4"
5/8" GYP. BD.
PROVIDE 3/4" PLY-WOOD
SUBSTRATE SHEATHING FULL
HEIGHT AND WIDTH OF
LOCKER SYSTEM AND METAL
LINER PANELS, ANCHOR TO
METAL STUD PARTITION
NEW CONCRETE CURB - CURB TO
BE FLUSH WITH FACE OF LOCKERS
5/8" GYP. BD. OVER
HAT CHANNEL
FURRING @ 16" O.C.
SOUND BATT
S.A.T. CEILING @ 9'-0"
T.O. GYPSUM BD. @ 10'-0"
EXIST'G. CONCRETE
SLAB
INSULATION FACING
12" W. x 18" D. SINGLE TIER
PRE-FINISHED METAL
LOCKER SYSTEM W/ MANUF.
STANDARD SLOPED TOP TO
MATCH LOCKER FINISH
CONT. BEVEL CUT 2x P.T. WOOD
SLEEPERS IMBEDDED INTO
CONCRETE CURB, ANCHOR PER
MANUF. RECOMMENDATIONS
METAL LINER PANEL AND
FRP - TO EXTEND TO 8'-8"
A.F.F. UNLESS OTHERWISE
NOTED.
METAL LINER PANEL
CLOSURE TRIM
14 GA 8" CEILING SUPPORT FRAMING @ 24" O.C. -
PROVIDE BRIDGING AND BRACING PER SSMA
REQUIREMENTS
UNFACED BATT INSULATION W/
INSULATION SUPPORT TIES AS
REQUIRED BY MANUFACTURER
RIM TRACK ATTACHED TO VERTICAL METAL STUD,
CONT. TO RECV. CEILING SUPPORT FRAMING, TYP.
WALL CONT. TO ROOF DECK, BRACE AS REQ. BY MANF.
DOUBLE 3 5/8"
METAL STUD
PARTITIONS @ 16"
O.C., SEE NOTES ON
WALL TYPE WT-2.
EXTEND HAT
CHANNEL FURRING
AND GYP BD. OVER
FACE OF
CONCRETE CURB
CONTRACTORS OPTION: USE 8" METAL STUDS @
16" O.C. IN LIEU OF DOUBLE 3 5/8" METAL STUDS.
PROVIDE 30# FELT
BOND BREAK AT
CURB JUNCTURE
TIE PARTITIONS
TOGETHER W/ MTL.
STUD TIES @ 4'-0"
O.C. VERTICAL
SLOPE SHALL BE MANUF.
STANDARD SLOPE,
PROVIDE END CLOSURES
TO MATCH LOCKER
MATERIAL AND FINISH
PROVIDE CONT. HORIZ.
BLOCKING BETWEEN
STUDS @ TOP OF
SHEATHING AND PEMB
LINER PANEL JUNCTURE
NOTE: G.C. COORDINATE
ELEVATION BETWEEN
BOTTOM OF PEMB LINER
PANEL AND TOP OF
SLOPED TOP OF LOCKERS
MAINT. BAY
HEAD
JAMB
SILL
DOOR, SEE
SCHEDULECORRIDOR 100
PEMB J-TRIM
METAL LINER
PANEL
PEMB J-TRIM
METAL LINER
PANEL
DOOR, SEE
SCHEDULE
HOLLOW METAL
FRAME
CREW RM. 107
5/8" GYP. BD. OVER
HAT CHANNEL
FURRING @ 16" O.C.
5/8" GYP. BD. OVER
HAT CHANNEL
FURRING @ 16" O.C.
CONT. J-MOLD AND
CAULK JOINT AT
FRAME JUNCTURE
CONT. J-MOLD AND
CAULK JOINT AT
FRAME JUNCTURE
JAMB ANCHORS, (3)
REQ'D. EA. JAMB
PEMB J-TRIMFACED SOUND BATT
10 5/8"
3/4" PLYWOOD
MTL. STUD
HEADER FRAME
EA. PARTITION
DBL. MTL. STUD
PARTITION
10 5/8"
HOLLOW METAL
FRAME
DBL. STUDS @
JAMBS
3/4" PLYWOOD
HOLLOW METAL
FRAME
ALUM. THRESHOLD,
SEE HARDWARE
DOOR, SEE
SCHEDULE
PEMB J-TRIM
BEYOND
JAMB ANCHOR,
(3) REQ'D. EA.
JAMB
CONCRETE
CURB BEYOND
EXIST'G. METAL
WALL PANEL
EXIST'G. PEMB WALL GIRT
5/8" GYP. BD. SOFFIT
PROVIDE TRIM AT
HEAD AND JAMB AT
NEW OPENING
5/8" GYP. BD. OVER 3 5/8"
MTL. STUDS @ 16" O.C.
PROVIDE FRAMING AT
NEW OPENING
CAULK EACH SIDE, CONT.
ALUM. CANOPY
SYSTEM
HOLLOW METAL FRAME
DOOR, SEE SCHEDULE
ALIGN W/ JAMB FRAME
HEAD
JAMB
5/8" GYP. BD. OVER 3 5/8"
MTL. STUDS @ 16" O.C.
5/8" GYP. BD. JAMB CLOSURE
PANEL CLOSURE STRIP
PROVIDE JAMB TRIM
SILL
CAULK EACH SIDE, CONT.
HOLLOW METAL FRAME
DOOR, SEE SCHEDULE
ANCHOR 1/2" FURRING
TO JAMB FRAMING
ALIGN W/ JAMB FRAME
ALUM. THRESHOLD,
SEE HARDWARE
HOLLOW METAL
FRAME
DOOR, SEE SCHEDULE
CAULK EACH SIDE, CONT.
BASE, SEE ROOM
FINISH SCHEDULE
JAMB TRIM, EXTEND
DOWN FULL LENGTH OF
FRAME
EXIST'G. PEMB INSUL.
FILL GIRT CAVITY W/
BATT INSULATION
UNFACED SOUND BATT
UNFACED SOUND BATT
INSULATION FACING
EXIST'G. METAL
WALL PANEL
EXIST'G. PEMB INSUL.
FILL GIRT CAVITY W/
BATT INSULATION
EXIST'G. CONCRETE
SLAB
FILL GIRT CAVITY W/
BATT INSULATION
INSULATION FACING
PROVIDE FRAMING AT
NEW OPENING
HEAD
JAMB
MTL. STUD SYSTEM
HEADER FRAMING
5/8" GYPSUM BOARD
UNFACED SOUND BATT
HOLLOW METAL FRAME
DOOR, SEE SCHEDULE
CAULK EACH SIDE, CONT.
5/8" GYPSUM BOARD
DOUBLE STEEL STUDS
UNFACED SOUND BATT
HOLLOW METAL
FRAME
DOOR, SEE SCHEDULE
CAULK EACH SIDE,
CONT.
VARIES
VARIES
SEE NOTE BELOW
SEE NOTE BELOW
NOTE: PLASTIC WALL PANELS OVER
GYP. BD. AT DOOR #2, #4, AND #5.
PANEL INSTALLER SHALL CAULK
PERIMETER OF DOOR FRAMES
AFTER PANEL INSTALLATION.
CREW ROOM
MAINT. BAY
OFFICE
OFFICE
OFFICE
CORRIDOR
TOILET
1 1 1
3 3 3
A104
A103
G A104
COORD. CEILING GRID LAYOUT
WITH CEILING GRID SUPPORT
FRAMING LAYOUT, TYP.
HEAD
METAL WALL PANEL
PEMB THERMAL
INSUL. SYSTEM
ALUM. WINDOW UNIT "B"
CAULK EACH SIDE,
CONT.
PEMB WALL GIRT
PANEL CLOSURE STRIP
PEMB HEADER TRIM
PEMB JAMB FRAME
JAMB
PEMB JAMB FRAME
PANEL CLOSURE
STRIP
PEMB SILL TRIM
PEMB JAMB TRIM
SILL
PEMB CHANNEL FRAME
THERMAL BLOCK
THERMAL BLOCK
3 1/4" 4 3/4"
3 1/4" 4 3/4"
METAL WALL PANEL
PEMB THERMAL
INSUL. SYSTEM
ALUM. WINDOW UNIT "B"
CAULK EACH SIDE,
CONT.
THERMAL BLOCK
ALUM. WINDOW UNIT "B"
PANEL CLOSURE STRIP
PEMB SILL TRIM
CAULK EACH SIDE,
CONT.
THERMAL BLOCK
METAL WALL PANEL
PEMB THERMAL INSUL.
SYSTEM
PEMB
TRIM
PEMB
TRIM
PEMB
TRIM
PAINTED 5/8" GYP. BD.
OVER 3 5/8" METAL STUD
FRAMING @ 16" O.C.
T.O. GYP. BD. @
10'-0"
14 GA 8" CEILING SUPPORT
FRAMING @ 24" O.C. -
PROVIDE BRIDGING, RIM
TRACK AND BRACING PER
SSMA REQUIREMENTS
S.A.T. CEILING @ 9'-0"
UNFACED BATT
INSULATION W/
INSULATION SUPPORT
TIES AS REQUIRED BY
MANUFACTURER
PAINTED 5/8" GYP. BD.
OVER 8" METAL STUD
FRAMING @ 16" O.C.
S.A.T. CEILING @ 9'-0"
2'-6"
A
R C H I T E
C
T
D A
V
I D
M. SAM
O K
A R
K
E N T U C K
Y
REG ISTERED
OF
NO.
COMMONWEALTH
WWW.CLOTFELTER-SAMOKAR.COM
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605
AS-BUILT DATE
DECA LOG #
DESCRIPTION OF REVISIONS DATE
DESCRIPTION OF REVISIONS DATE
DRAWING INFORMATION
A & E FILE NO.
DRAWN BY
CHECKED BY
PHASE
RTA DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
ACCOUNT NO.
DRAWING DATE
KYTC MAINTENANCE FACILITY MADISONVILLE, KENTUCKY
/2
/2
:3 :5
P
M
DMS
03/27/25
AHH
SCHEDULES AND DETAILS
A103
C
609-C940-Z001-A78
03/28/25
SCALE: 3/8" = 1'-0"
WINDOW ELEVATIONS
SCALE: 1" = 1'-0"
SECURITY GRILL DETAIL
SCALE:
DETAIL
A103 1 1/2" = 1'-0"
D
SCALE:
DETAIL
A103 1 1/2" = 1'-0"
E
SCALE:
DETAIL
A103 3/4" = 1'-0"
G
SCALE:
DETAIL
A103 1 1/2" = 1'-0"
B
SCALE:
DETAIL
A103 1 1/2" = 1'-0"
A
SCALE:
DETAIL
A103 1 1/2" = 1'-0"
C
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN
SHEET NOTES
1 2x2 ACOUSTICAL TILE CEILING SYSTEM @ 9'-0"
ABOVE FINISH FLOOR.
2 PAINTED 5/8" GYPSUM BOARD SOFFIT OVER METAL
STUD FRAMING @ 16" O.C., BOTTOM OF FINISHED
SOFFIT @ 7'-0" +/- ABOVE FINISH FLOOR.
3 ALUMINUM CANOPY SYSTEM - REFER TO DETAIL
2/A104.
4 SLOPED TOP LOCKER SYSTEM BELOW.
5 EXTEND METAL STUD WALL AND INSULATION UP TO
UNDERSIDE OF ROOF STRUCTURE.
SCALE:
DETAIL
A103 1 1/2" = 1'-0"
F
ADDENDUM 3 06/18/25
ADDENDUM 5 07/03/25
SCALE:
DETAIL
A103 3/4" = 1'-0"
H
BradleyABeatty Rectangle
BradleyABeatty
5/8" GYP. BD. OVER
HAT CHANNEL
FURRING @ 16" O.C.
UNFACED BATT
INSULATION
EXIST'G. CONCRETE SLAB
S.A.T. CEILING SYSTEM
CEILING 9'-0"
14 GA 8" CEILING SUPPORT FRAMING @ 24"
O.C. - PROVIDE BRIDGING AND BRACING
PER SSMA REQUIREMENTS
NEW CONCRETE
CURB
BASE, SEE
SCHEDULE
WALL EXTENDS TO
UNDERSIDE OF
ROOF DECK ABOVE
JOIST BRG. 10'-0"
METAL LINER PANEL
SILL FLASHING
METAL LINER
PANEL - TO BE
8'-8" A.F.F.
LINER PANEL 8'-8"
PROVIDE 3/4" PLY-
WOOD SUBSTRATE
SHEATHING FULL
HEIGHT AND WIDTH
METAL LINER
PANELS, ANCHOR TO
METAL STUD
PARTITION
8"
2"
5/8" GYP BOARD
UNFACED BATT
INSULATION W/
INSULATION SUPPORT
TIES AS REQUIRED BY
MANUFACTURER
RIM TRACK ATTACHED TO VERTICAL METAL STUD,
CONT. TO RECV. CEILING SUPPORT FRAMING, TYP.
EXTEND HAT
CHANNEL FURRING
OVER FACE OF CURB1
DOUBLE 3 5/8" METAL
STUD PARTITIONS @
16" O.C., SEE NOTES
ON WALL TYPE WT-2.
CONTRACTORS OPTION: USE 8" METAL STUDS @
16" O.C. IN LIEU OF DOUBLE 3 5/8" METAL STUDS.
TIE PARTITIONS
TOGETHER W/ MTL.
STUD TIES @ 4'-0"
O.C. VERTICAL
E
X
IS
T 'G
G
IR
T
S A
B O
V E
EXIST'G. PEMB WALL PANEL
EXIST'G. PEMB THERMAL
INSUL. SYSTEM
5/8" GYP. BD. EACH
SIDE OVER 3 5/8" MTL.
STUDS @ 16" O.C.
UNFACED SOUND BATT
EXIST'G. PEMB
RIGID FRAME
8" COLD-ROLLED STEEL
CHANNEL SEGMENTS FROM
FLOOR TO 12'-0"+/-, ANCHOR
TO GIRTS WITH CLIP ANGLE
1'-0 1/2"
/8
11 1/4"
MAINT. BAY
EXIST'G. FIN. FLOOR
ELEV. = 0'-0"
LOCKERS
PROVIDE LT. GA.
BRACING TO EXIST'G.
PURLINS AS REQUIRED
PER MANF. SPEC.
OFFICE
C
A
REFER TO CEILING
SUPPORT PLAN ON A101
STEEL PIPE BOLLARD,
SEE DETAIL ON SHEET
G001
EXIST'G. HVAC
UNIT TO REMAIN
EXIST'G. GUTTER /
D.S. TO REMAIN, TYP.
A A A
NEW PRE-FIN. MTL.
CANOPY
NEW PRE-FIN. MTL.
CANOPY
NEW PRE-FIN. MTL.
CANOPY
EXIST'G. HVAC
UNIT TO REMAIN
C C
(F
.V
(F
.V
EYE
WASH
MOP
SINK
SPLASH PANEL - 8'-0"T x 8'-0"W
FRP PANEL OVER 3/4" PLY
T.O. CURB
GYPSUM BOARD
A103
G
METAL LINER PANEL
METAL LINER PANEL
METAL LINER PANEL
8'-0"
A104
FRP PANEL AT WING WALLS, ALL (3) SIDES -
8'-0"T PLASTIC PANEL OVER 3/4" PLY. TRIM AS
REQ. BETWEEN LINER PANEL AND FRP PANELS.
FRP PANEL AT WING WALLS, ALL (3) SIDES - 8'-0"T
PLASTIC PANEL OVER 3/4" PLY. TRIM AS REQ.
BETWEEN LINER PANEL AND FRP PANELS.
METAL LINER PANEL
CORNER TRIM
B.O. CANOPY
ELEV. = 8'-0"
PRE-FINISHED ALUM. FLAT
BOTTOM DECKING
PRE-FINISHED METAL LINER PANEL
HANGER ROD ASSEMBLY
PRE-FINISHED EXTRUDED
ALUM. GUTTER / FASCIA
THREADED ADJUSTMENT ROD
WALL FLASHING, BY CANOPY SUPPLIER,
COLOR SHALL MATCH CANOPY COLOR
PRE-FINISHED METAL SILL
TRIM BY PEMB SUPPLIER
PANEL CLOSURE STRIP
NOTE: STACKED WALL PANELS ONLY
OCCUR AT CANOPY LOCATIONS.
CANOPY SUPPORT
FRAMING BY PEMB
SUPPLIER
PVC PIPE SPACER SLEEVES
ALUM. CANOPY SUPPORT BEAM
BASIS OF DESIGN, MAPES
"SUPER LUMIDECK HANGER
ROD CANOPY"
HOLLOW METAL DOOR
AND FRAME, SEE
SCHEDULE
PRE-FINISHED METAL
WALL PANEL
PRE-FINISHED METAL WALL PANEL
PRE-FINISHED METAL HEAD
TRIM
PERIMETER SEALANT, EACH
SIDE OF FRAME
STEEL CLEVIS
THREADED ADJUSTMENT
ROD
PANEL CLOSURE STRIP
PRE-FINISHED METAL JAMB TRIM
8" BY-PASS GIRT
CANOPY MANUF. STANDARD
CONNECTION, THRU THREADED ROD
W/ BACKING PLATE. PROVIDE PVC
PIPE SPACER SLEEVES FULL DEPTH
OF PANEL AND CHANNEL SUPPORT
PROVIDE PERIMETER SEALANT AROUND
EACH FACE PLATE OF HANGER ROD
ASSEMBLY
PVC PIPE SPACER SLEEVES
PRE-FINISHED METAL HEAD TRIM
CANOPY SCUPPER
BEYOND
A104
A104
C C C C
(F
.V
(F
.V
(F
.V
(F
.V
NEW PRE-FIN. MTL.
CANOPY
EXIST'G. HVAC
UNIT TO REMAIN
EXIST'G. HVAC
UNIT TO REMAIN
F.R.P. PANEL SYSTEM
NEW CONCRETE CURB
EXIST'G. CONCRETE SLAB
PANEL SYSTEM SEALANT
PANEL SYSTEM END CAP
PAINTED GYP. BD.
BASE, SEE SCHEDULE
MTL. STUD WALL
UNFACED SOUND BATT
7/8" MTL. HAT
CHANNEL8
8"
3/4" PLYWOOD
SUBSTRATE
CONTRACTORS OPTION: USE 8" METAL STUDS @
16" O.C. IN LIEU OF DOUBLE 3 5/8" METAL STUDS.
A
R C H I T E
C
T
D A
V
I D
M. SAM
O K
A R
K
E N T U C K
Y
REG ISTERED
OF
NO.
COMMONWEALTH
WWW.CLOTFELTER-SAMOKAR.COM
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605
AS-BUILT DATE
DECA LOG #
DESCRIPTION OF REVISIONS DATE
DESCRIPTION OF REVISIONS DATE
DRAWING INFORMATION
A & E FILE NO.
DRAWN BY
CHECKED BY
PHASE
RTA DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
ACCOUNT NO.
DRAWING DATE
KYTC MAINTENANCE FACILITY MADISONVILLE, KENTUCKY
/2
/2
:3 :5
P
M
DMS
03/27/25
AHH
BUILDING / WALL SECTIONS
A104
C
609-C940-Z001-A78
03/28/25
SCALE:
DETAIL
A104 1 1/2" = 1'-0"
SCALE:
DETAIL
A104 1 1/2" = 1'-0"
SCALE:
DETAIL
A104 1/8" = 1'-0"
SCALE:
BUILDING ELEVATION
A104 1/8" = 1'-0"
SCALE:
DETAIL
A104 3/8" = 1'-0"
SCALE:
DETAIL
A104 1 1/2" = 1'-0"
SCALE:
BUILDING ELEVATION
A104 1/8" = 1'-0"
SCALE:
DETAIL
A104 1 1/2" = 1'-0"
ADDENDUM 3 06/18/25
ADDENDUM 5 07/03/25
BradleyABeatty Rectangle
BradleyABeatty
KYTC MAINTENANCE FACLITY
MADISONVILLE, KENTUCKY
CLOTFELTERSAMOKAR NO. 2418
MARCUM NO. 24626
MECHANICAL AND ELECTRICAL ADDENDUM 6.00
JULY 2, 2025
The following Addendum Items shall be made part of the Contract Documents for the referenced project.
6.01 Refer to Drawing E101 and attached Light Fixture Cut Sheet. The lighting fixture attached is the fixture to be furnished by the Owner and installed by the
Contractor. The emergency battery pack to be furnished by the Contractor
(referenced in Addendum 4.00) shall be compatible with fixture to be furnished.
Attachments:
1. Light Fixture Cut Sheet
END OF ADDENDUM 6.00
SKYLINE G4
Power Selectable Linear Highbay
DESCRIPTION
LED Linear Highbay/Power Selectable/ 120-277V(347-480V optional with transformer)/ 0-10V Dimming/95°x95° distribution comes standard (40°x110° optional)
PRODUCT SPECIFICATIONS
PRODUCT FEATURES
Architectural grade compact design Frosted lens eliminates glare
PF>0.9, THD<20%
95°x95° distribution comes standard (40°x110° aisle distribution optional) 120-277Vac universal input(347-480V optional with step down transformer)
Emergency backup options available Receptacle Pre-installed, PNP Sensor order separately BLE Mesh Control(LLLC) and Circuit Level Control(LALC) options available Feature Power Selectable Technology. Adjust power between three selections V-hook and chain mounting accessories included
HBEL
HBEL
Power Selectable Linear Highbay
SKYLINE G4
Power Selectable Linear Highbay
©2022 ATG LED Lighting
10588 Monte Vista Avenue
Montclair, CA 91763 www.atgledlighting.com
T: 951.245.6222
E: sales@atgledlighting.com Page 02 of 08
DAYLIGHT0-10V DIM
Data subject to change. Last Edited: April 24, 2024 10:00 PM
Watts (W)
Efficacy
(LM/W)
Lumens (LM)Parent Part Number DLC Listed Children Part Number Product ID Input
HBELD-270P-40F-G4
HBELD-270P-50F-G4
HBELC-200P-40F-G4
HBELC-200P-50F-G4
HBELB-135P-40F-G4
HBELB-135P-50F-G4
HBELD-270P-40F-[Blank,Sx,Ex]-G4
HBELD-270P-40F-[Blank,Sx,Ex]-G4 *factory setting 230W*
HBELD-270P-40F-[Blank,Sx,Ex]-G4 *factory setting 200W*
HBELD-270P-50F-[Blank,Sx,Ex]-G4
HBELD-270P-50F-[Blank,Sx,Ex]-G4 *factory setting 230W*
HBELD-270P-50F-[Blank,Sx,Ex]-G4 *factory setting 200W*
HBELC-200P-40F-[Blank,SxEx]-G4
HBELC-200P-40F-[Blank,SxEx]-G4 *default setting 185W*
HBELC-200P-40F-[Blank,SxEx]-G4 *default setting 155W*
HBELC-200P-50F-[Blank,SxEx]-G4
HBELC-200P-50F-[Blank,SxEx]-G4 *default setting 185W*
HBELC-200P-50F-[Blank,SxEx]-G4 *default setting 155W*
HBELB-135P-40F-[Blank,SxEx]-G4
HBELB-135P-40F-[Blank,SxEx]-G4 *default setting 115W*
HBELB-135P-40F-[Blank,SxEx]-G4 *default setting 100W*
HBELB-135P-50F-[Blank,SxEx]-G4
HBELB-135P-50F-[Blank,SxEx]-G4 *default setting 115W*
HBELB-135P-50F-[Blank,SxEx]-G4 *default setting 100W*
S-PHFYOE
S-90GWX7
S-VNGH2Q
S-1NPJRC
S-ITY3QC
S-MPN8G7
S-4C63PO
S-NQAZBM
S-V25KHZ
S-QPDFM6
S-7TJX38
S-K3N2WH
S-3WL7FP
S-5JLVE4
S-KT7M3P
S-2WIFUO
S-OQ8MEU
S-12C83P
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
120-277VAC
152.3
154.5
156.8
154.9
157.1
159.5
151.6
153.4
157.0
152.9
154.7
158.4
153.1
156.9
159.5
155.2
159.1
161.7
38,709
33,899
30,213
39,521
34,471
30,723
28,580
26,839
23,029
28,758
27,069
23,226
19,373
16,833
15,100
19,623
17,065
15,308
HBELB-400P-40F-G4
HBELB-400P-40F-[Blank,SxEx]-G4 Not Listed Yet 120-277VAC 400 150.0 60,000
HBELB-400P-40F-[Blank,SxEx]-G4 *default setting 340W* Not Listed Yet 120-277VAC 340 152.0 51,680
HBELB-400P-40F-[Blank,SxEx]-G4 *default setting 270W* Not Listed Yet 120-277VAC 270 154.0 41,580
HBELB-400P-50F-G4
HBELB-400P-50F-[Blank,SxEx]-G4 Not Listed Yet 120-277VAC 400 151.0 60,400
HBELB-400P-50F-[Blank,SxEx]-G4 *default setting 340W* Not Listed Yet 120-277VAC 340 153.0 52,020
HBELB-400P-50F-[Blank,SxEx]-G4 *default setting 270W* Not Listed Yet 120-277VAC 270 155.0 41,850
*Data for 400P is based on extrapolated data, other data is based on DLC reported data
PHYSICAL SPECIFICATIONS
16.5”
31.1” 44.1”
22.8”
.2
.2
.2
©2022 ATG LED Lighting
10588 Monte Vista Avenue
Montclair, CA 91763 www.atgledlighting.com
T: 951.245.6222
E: sales@atgledlighting.com Page 03 of 08
Depth
HBELB-135P-XXF-G4
HBELC-200P-XXF-G4
HBELD-270P-XXF-G4
HBELE-400P-XXF-G4
16.5“
22.8”
31.1“
44.1”
10.2“
10.2“
10.2“
10.2“
1.77”
1.77”
1.77”
1.77”
LIGHT DISTRIBUTION PATTERN
105O
90O
75O
60O
45O
30O
105O
90O
75O
60O
45O
30O
15O 0O 15O
105O
90O
75O
60O
45O
30O
105O
90O
75O
60O
45O
30O
15O 0O 15O cd/klm -------C0-C180 -------C90-C270 cd/klm -------C0-C180 -------C90-C270
总装图
(1%&2
(2%&3
总装图
,1%&2
HBEL
HBEL
Power Selectable Linear Highbay
SKYLINE G4
Power Selectable Linear Highbay
HBELB
HBELD HBELE
HBELC
Part Number Length Width
AISLE DISTRIBUTION STANDARD DISTRIBUTION
Data subject to change. Last Edited: April 24, 2024 10:00 PM
ATG Code
LALC-LOCAL AREA LIGHTING CONTROL (CIRCUIT LEVEL)*
Description Model Number
ATG Code
LALC-LOCAL AREA LIGHTING CONTROL (CIRCUIT LEVEL)
Description Model Number
RM51 IFS05SE NO LENS IFS05SE LOW BAY LENS IFS05SE MID BAY LENS IFS05SE HIGH BAY LENS
LUMEN MAINTENANCE
©2022 ATG LED Lighting
10588 Monte Vista Avenue
Montclair, CA 91763 www.atgledlighting.com
T: 951.245.6222
E: sales@atgledlighting.com Page 04 of 08
CONTROL SYSTEM
HBELB-135P-XXF-G4
HBELC-200P-XXF-G4
HBELD-270P-XXF-G4
HBELE-400P-XXF-G4
Projected per IESNA TM-21-11 DLC Reported Hours = Max 6x LM-80 tested duration (SSC STWxC25B-XX@9,000 Hrs)
Ambient Test Temp Reported Hrs 0 Hrs 25,000 Hrs 50,000 Hrs 100,000 Hrs Calculated L70 Hrs
250C/770F
250C/770F
250C/770F
250C/770F
60,000
60,000
60,000
60,000
0.94
0.94
0.94
0.94
0.88
0.88
0.88
0.88
0.85
0.85
0.86
0.86
0.76
0.76
0.77
0.77
132,000
132,000
134,000
134,000
Model TM21-11 60,000 Hrs
ATG Code
W4
W5
P7
P4
L1
L2
L3
L4
Al
W4
W9
P5
P7
Bi-level PIR Occ sensor
12V Wireless Fixture Controller
Room controller, KOmounted120-277n/12VCand0-10Vout/16A
12V power supply for �xture mount with relay
PSC-BL-I-FM-DCO-BLE-SR
PSC-WCM-50-DCO-BLE-SR
PSC-WCM-450-BLE-SR
PSC-AC-PP-700C
SO
RI
Microwave Motion Sensor for G4 Skyline Highbay,12VDC Driven
Remote for IFS05SE
IFS05SE
RM-51
Bi-Level PIR Occ sensor
Bi-Level PIR Occupancy Sensor Side Mounted,100-277V
12VPower Supplyfor�xture mountw/relay
12V Power Supplyfor �xture mount (no relay)
LENS.LOW BAY 30FT H X60FT DIA WH
LENS.LOWBAY 30FT H X60FT DIA BN
LENS.HIGH BAY 4FT HX 70FT DIAWH
LENS.HIGH BAY 4FT HX 70FT DIA BN
Arm.High Bay O�set extension
PSC-BL-I-FM-DCO-BLE-SR
PSC-BL-I-FM-110-BLE-SR
PSC-AC-PP-700C
PSC-AC-PP-400
PIR-BLO1-F3-LBL
PIR-BL01-F3-LBL-BN
PIR-BLO1-F5-HBL
PIR-BL01-F5-HBL-BN
ARM
LLLC-LUMINAIRE LEVEL LIGHTING CONTROL (MESH NETWORK)*
Description Model Number
HBEL
HBEL
Power Selectable Linear Highbay
SKYLINE G4
Power Selectable Linear Highbay
* For more information about LLLC and LALC system, please contact our sales team.
©2022 ATG LED Lighting
10588 Monte Vista Avenue
Montclair, CA 91763 www.atgledlighting.com
T: 951.245.6222
E: sales@atgledlighting.com Page 05 of 08
For more information about LLLC and LALC system, please see accessory list below and contact our sales team.
* Please contact our sales team for lead time about Aisle lens.
** Accessories are ordered separately. These are not included in default packing.
400P model is…
This is the start of the file's text. The full file is on GovTribe.