Addendum Three .pdf

PDF 1 MB Posted

Attached to
RFB-266-25 Maintenance Facility Renovation Madisonville KY
Solicitation number
RFB 785 2500000732 7
Issued by
Hardin County, Kentucky

About this file

This is Addendum Three to Invitation to Bid No. RFB-266-25 issued by the Commonwealth of Kentucky Department for Facilities and Support Services, Division of Engineering and Contract Administration, for maintenance facility renovations at the Kentucky Transportation Cabinet (KYTC) facility in Madisonville, Kentucky. The project involves interior fit-up work including metal liner panels, formed metal wall panels, painting, windows, doors, lockers, canopy systems, plumbing, HVAC, electrical, and miscellaneous interior finishes. The addendum modifies specifications and drawings by adding Section 07 42 13.13 for Formed Metal Wall Panels, reissuing Sheets A101, A103, and A104 to reflect metal liner panel extents and details as part of the base bid, replacing Section 09 91 00 for Painting to match Phase 1 paint selections, and updating the specification table of contents. The official bid opening has been moved to July 1, 2025, at 1:30 p.m. Eastern Time. Metal locker specifications have been updated to include Republic Storage Company as the basis-of-design product with comparable alternatives from ArtMetal Products, DeBourgh Manufacturing, List Industries, Lyon Workspace Products, Penco Products, Scranton Products, and LockersMFG. Paint selections are based on Sherwin Williams products or comparable alternatives from Benjamin Moore, Coronado Paint, Porter Paints, PPG Architectural Finishes, and Farrell-Calhoun, with specific attention to interior and exterior latex systems, alkyd paints, and high-performance epoxy coatings.

The addendum specifies technical requirements for metal liner panels including 26-gauge metallic-coated steel with siliconized polyester finish in colors selected by the architect, 12-inch on-center major rib spacing, 36-inch panel coverage, and 1.25-inch panel height matching existing conditions. Painting specifications detail multiple primer and topcoat systems for concrete, steel, galvanized metal, wood, and gypsum board substrates, with minimum film thickness requirements and application standards complying with manufacturer recommendations and MPI Architectural Painting Specification Manual guidelines. The project includes provisions for exterior satin and semigloss latex finishes, interior flat and eggshell latex options, and specialized high-performance epoxy and acrylic coatings for traffic surfaces and mechanical equipment. All work must comply with current applicable Kentucky Building Codes and other state and local codes including the National Electrical Code and BOCA Mechanical Code. Items unclear regarding design intent must be brought to the owner's attention prior to bid for written clarification.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMONWEALTH OF KENTUCKY

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

INVITATION TO BID NO: RFB-266-25

FOR: Maintenance Facility Renovations Kentucky Transportation Cabinet Madisonville, Kentucky

DATE: June 20, 2025

RFB-785-2500000732

ADDENDUM NO. Three (3)

BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING

UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.

Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.

Item 2: Official Bid Opening has been moved to July 1, 2025, at 1:30 P.M. Eastern Time

END OF ADDENDUM

Invitation to Bid No. RFB-266-25 For: Maintenance Facility Renovations Kentucky Transportation Cabinet

Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration

KYTC Maintenance Facility D-2 Hopkins County Madisonville, KY

Engineering File No. 609-C940-Z001-A78 C/S Project No. 2418

Addendum No. 3 June 18, 2025

The following Addendum Items shall be made part of the Contract Documents for this Project.

SPECIFICATIONS

1) Item #1

Refer to specification 10 51 13 - Metal Lockers. Replace the language under subsection 2.3 in its entirety with the following language:

A. Basis-of-Design Product: Subject to compliance with requirements, provide Standard

Lockers by Republic Storage Company or comparable product by one of the following:

1. ArtMetal Products.

2. DeBourgh Mfg. Co.

3. List Industries.

4. Lyon Workspace Products.

5. Penco Products.

6. Scranton Products.

7. LockersMFG

2) Item #2

Specification section 07 42 13.13 – Formed Metal Wall Panels has been added.

3) Item #3

Reissue Sheet A101.

Sheet A101 has been reissued to show extents of metal liner panel as a part of the base bid.

4) Item #4

Reissue Sheet A103.

Detail A103 has been revised. This detail applies to all locations where the metal liner panel is shown.

5) Item #5

Reissue Sheet A104.

Sheet A104 has been reissued to reflect metal liner panel elevations and details.

6) Item #6

Specification section 09 91 00 – Painting has been replaced to match Phase 1 specified paint selections.

7) Item #7

Specification table of contents has been updated to reflect the current specification book in its entirety. Please refer to the specification table of contents released with this Addendum.

END OF ADDENDUM

A104

A102

CREW ROOM

SHOWER

ADA TOILET

FEMALE

TOILET

MECH. RM.

MAINT. BAY

25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"

25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"

T

O O

U T

S

ID

E F

A C

E O

F E

X

IS

T 'G

G

IR

T

S

F

IE

L D

V E

R

IF

Y

A L

IG

N

W

IT

H D

O O

R J

A M

B S

A104

A104

ALIGN CENTERLINE WITH JAMB

2'-0" 2'-0"

18'-0" 60'-0" +/- TRENCH DRAIN

40'-0"

6'-0"

/8

OFFICE

OFFICE

OFFICE

SPRINKLER DRAIN DOWN

TOILET

IC

E

A104

A104

2 2

MTL LINER PANEL

16'-8 15/16"

MTL LINER PANEL

13'-8 3/8"

MTL LINER PANEL

30'-0 11/16"

FRP

8'-0"

M T

L L

IN

E

R P

A N

E L

/1

4 7/8" FRP 4 7/8" FRP

1. ALL WORK SHALL BE EXECUTED TO

SUBSTANTIALLY COMPLY WITH THE CURRENT

APPLICABLE KENTUCKY BUILDING CODES AND

OTHER APPLICABLE STATE AND LOCAL CODES

HAVING JURISDICTION OVER THIS PROJECT,

I.E., NATIONAL ELECTRICAL CODE, AND BOCA

MECHANICAL CODE.

2. ITEMS UNCLEAR AS TO THE DESIGN INTENT OR

APPLICATION SHALL BE BROUGHT TO THE

OWNER'S ATTENTION PRIOR TO BID FOR

WRITTEN CLARIFICATION.

GENERAL NOTES

A

R C

H I T E C

T

D A

V

I D

M. SAM

O K

A R

K

E N T U C K

Y

R

EG ISTERED

OF

NO.

COMMONWEALTH

WWW.CLOTFELTER-SAMOKAR.COM

REVISION HISTORY OF THIS DRAWING

DRAWING NO.

228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605

AS-BUILT DATE

DECA LOG #

DESCRIPTION OF REVISIONS DATE

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

A & E FILE NO.

DRAWN BY

CHECKED BY

PHASE

RTA DATE

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

ACCOUNT NO.

DRAWING DATE

KYTC MAINTENANCE FACILITY MADISONVILLE, KENTUCKY

/1

/2

:2 :3

P

M

DMS

03/27/25

AHH

BUILDING FLOOR PLAN

A101

C

609-C940-Z001-A78

03/28/25

SCALE: 1/8" = 1'-0"

BUILDING FLOOR PLAN

SHEET NOTES

1 EXISTING DUCTWORK TO BE INSULATED - REFER TO

MECHANICAL DRAWINGS.

2 NEW EXTERIOR HOSE BIB - REFER TO PLUMBING

DRAWINGS.

3 NEW INTERIOR HOSE BIB - REFER TO PLUMBING

DRAWINGS.

4 NEW TRENCH DRAIN EXTENSION - REFER TO

PLUMBING DRAWINGS.

5 NEW ALUMINUM CANOPY SYSTEM. PROVIDE FOR

BLOCKING WITHIN EXISTING WALL FRAME, PATCH

AND REPAIR EXISTING INTERIOR BUILDING WALL

FINISH/INSULATION SYSTEM AS REQUIRED TO

COMPLETE WORK. TYPICAL WHERE INDICATED.

N

ADDENDUM 3 06/18/25

FIXED

ALUMINUM WINDOW

INSULATED GLASS

TYPE GL-2

SEC. 085113

D

A103

A

W

IN

D O

W S

IL

L

E

E

V

D

A103

D

A103

3'-0"

SLIDING SERVICE

WINDOW TEMPERED

GLASS TYPE GL-1

SEC. 085653

E

A103

B

W

IN

D O

W S

E

V

E

A103

E

A103

3'-0" 4'-0"

W

IN

D O

W S

E

V

FIXED

ALUMINUM WINDOW

INSULATED GLASS

TYPE GL-2

SEC. 085113

F

A103

F

A103

F

A103

C

1/2" x 3/4" STEEL FLAT

BAR STOCK

STRAP: 1/2" x 2" STEEL

FLAT BAR STOCK

ELEVATION

PLAN

WINDOW TYPE "A"

PEMB PRE-FINISHED

JAMB TRIM

PEMB PRE-FINISHED HEAD

TRIM

SECTION

C L E

A R

O U

T T

O O

U T

O F

F L A

T B

A R

C L E

A R

F

IE

L D

V E

R

IF

Y

W

IN

D O

W

"A

R O

U G

H O

P E

N

IN

G

3'-0" +/- WINDOW "A" ROUGH OPENING

STRAP: 1/2" x 2"

STEEL FLAT BAR

STOCK

EQ. EQ.

2"

3/4"

4"

3/4"

4"

3/4"

4"

3/4"

4"

3/4"

EQ. 2"

3/4"

4"

3/4"

4"

3/4"

4"

3/4"

4"

3/4"

EQ.

TAMPER PROOF THRU-BOLT

TO PEMB JAMB FRAME, 1 BOLT

AT EA. END OF STRAPS

1/2" 2"

TAMPER PROOF

THRU-BOLT

1/2" x 3/4" STEEL

FLAT BAR STOCK

STRAP: 1/2" x 2" STEEL

FLAT BAR STOCK

ALIGN EXT. FACE OF STRAP W/

EXT FACE OF FRAMED OPENING

ALUM. WINDOW UNIT "A"

CAULK EACH SIDE, CONT.

3"+/- 3 1/4" 5 5/8"

/4

STEEL SECURITY GRILL

ALIGN W/ JAMB FRAME

ALUM. WINDOW UNIT "A"

STEEL SECURITY GRILL

SILL EXTENSION BY

WINDOW SUPPLIER

ALIGN W/ JAMB FRAME 3"+/- 3 1/4" 7 1/4"

5/8" GYP. BD. OVER 3 5/8"

MTL. STUD FURRING @

16" O.C.

UNFACED SOUND BATT

5/8" GYP. BD. JAMB

CLOSURE

SOLID SURFACE

WINDOW STOOL

CONT. CLEAR SEALANT

AROUND PERIMETER

1"

5/8" GYP. BD. OVER 3 5/8"

MTL. STUD FURRING @

16" O.C.

UNFACED SOUND BATT

SOLID SURFACE WINDOW

STOOL OVER 1/2" SUB-SILL

5/8" GYP. BD. JAMB

CLOSURE

SOLID SURFACE

APRON

CONT. CLEAR SEALANT

AROUND PERIMETER

STEEL SECURITY GRILL

ALUM. WINDOW UNIT "A"

PANEL CLOSURE STRIP

SILL EXTENSION BY

WINDOW SUPPLIER

HEAD

JAMB

SILL

EXIST'G. METAL

WALL PANEL

EXIST'G. PEMB WALL GIRT

PROVIDE TRIM AT

HEAD AND JAMB AT

NEW OPENING

5/8" GYP. BD. OVER 3 5/8"

MTL. STUDS @ 16" O.C.

PROVIDE FRAMING AT

NEW OPENING

EXIST'G. PEMB INSUL.

FILL GIRT CAVITY W/

BATT INSULATION

UNFACED SOUND BATT

INSULATION FACING

5/8" GYP. BD. SOFFIT

PANEL CLOSURE STRIP

EXIST'G. METAL

WALL PANEL

EXIST'G. PEMB INSUL.

FILL GIRT CAVITY W/

BATT INSULATION

PROVIDE JAMB TRIM

EXIST'G. METAL

WALL PANEL

EXIST'G. PEMB INSUL.

PROVIDE FRAMING AT

NEW OPENING

PROVIDE SILL FRAMING

AT NEW OPENING

HEAD

JAMB

SILL

5/8" GYP. BD. OVER MTL.

STUDS @ 16" O.C.

MTL. STUD SYSTEM

HEADER FRAMING

5/8" GYP. BD. OVER MTL.

STUDS @ 16" O.C.

SLIDING SERVICE

WINDOW "B"

1x3 PAINTED

WOOD APRON

CONT. CLEAR SEALANT

AROUND PERIMETER

SLIDING SERVICE

WINDOW "B"

STAINLESS STEEL

WINDOW SILL

5/8" GYP. BD.

OVER MTL.

STUDS @ 16" O.C.

UNFACED SOUND

BATT

UNFACED SOUND BATT

2x WD. BLOCKING

CAULK PERIMETER

BOTH SIDES

ALUM. HEAD FRAME

2x WD. BLOCKING

SLIDING SERVICE

WINDOW "B"

STAINLESS STEEL

WINDOW SILL

12"

4"

4"

5/8" GYP. BD.

PROVIDE 3/4" PLY-WOOD

SUBSTRATE SHEATHING FULL

HEIGHT AND WIDTH OF

LOCKER SYSTEM AND METAL

LINER PANELS, ANCHOR TO

METAL STUD PARTITION

NEW CONCRETE CURB - CURB TO

BE FLUSH WITH FACE OF LOCKERS

5/8" GYP. BD. OVER

8" METAL STUDS @

16" O.C.

PROVIDE CONT. HORIZ.

BLOCKING BETWEEN

STUDS @ TOP OF

SHEATHING AND LINER

PANEL J0INT

SOUND BATT

S.A.T. CEILING @ 9'-0"

T.O. GYPSUM

BD. @ 10'-0"

EXIST'G. CONCRETE

SLAB

INSULATION FACING

12" W. x 18" D. SINGLE TIER

PRE-FINISHED METAL

LOCKER SYSTEM W/ MANUF.

STANDARD SLOPED TOP TO

MATCH LOCKER FINISH

CONT. BEVEL CUT 2x P.T. WOOD

SLEEPERS IMBEDDED INTO

CONCRETE CURB, ANCHOR PER

MANUF. RECOMMENDATIONS

METAL LINER PANEL - TO BE

8'-8" A.F.F.

METAL LINER PANEL

CLOSURE TRIM

HEAD

JAMB

SILL

DOOR, SEE

SCHEDULE

HOLLOW METAL

FRAME

UN-FACED

SOUND BATT

5/8" GYP. BD. OVER 8"

MTL. STUDS @ 16"

O.C.

MTL. STUD JAMB

ANCHORS

DOUBLE STUDS

AT JAMB

/4

EXIST'G.

CONCRETE SLAB

SEALANT, BOTH

SIDES

HOLLOW METAL

FRAME

DOOR, SEE

SCHEDULE

MTL. CLOSURE

TRIM

ALUM. THRESHOLD,

SEE HARDWARE

METAL LINER PANEL

UN-FACED

SOUND BATT

INSULATION FACING5/8" GYP. BD. OVER 8"

MTL. STUDS @ 16"

O.C.

MTL. STUD SYSTEM

HEADER FRAMING

DOOR, SEE

SCHEDULE

HOLLOW METAL

FRAME

CAULK EACH

SIDE, CONT.

EXIST'G. METAL

WALL PANEL

EXIST'G. PEMB WALL GIRT

5/8" GYP. BD. SOFFIT

PROVIDE TRIM AT

HEAD AND JAMB AT

NEW OPENING

5/8" GYP. BD. OVER 3 5/8"

MTL. STUDS @ 16" O.C.

PROVIDE FRAMING AT

NEW OPENING

CAULK EACH SIDE, CONT.

ALUM. CANOPY

SYSTEM

HOLLOW METAL FRAME

DOOR, SEE SCHEDULE

ALIGN W/ JAMB FRAME

HEAD

JAMB

5/8" GYP. BD. OVER 3 5/8"

MTL. STUDS @ 16" O.C.

5/8" GYP. BD. JAMB CLOSURE

PANEL CLOSURE STRIP

PROVIDE JAMB TRIM

SILL

CAULK EACH SIDE, CONT.

HOLLOW METAL FRAME

DOOR, SEE SCHEDULE

ANCHOR 1/2" FURRING

TO JAMB FRAMING

ALIGN W/ JAMB FRAME

ALUM. THRESHOLD,

SEE HARDWARE

HOLLOW METAL

FRAME

DOOR, SEE SCHEDULE

CAULK EACH SIDE, CONT.

BASE, SEE ROOM

FINISH SCHEDULE

JAMB TRIM, EXTEND

DOWN FULL LENGTH OF

FRAME

EXIST'G. PEMB INSUL.

FILL GIRT CAVITY W/

BATT INSULATION

UNFACED SOUND BATT

UNFACED SOUND BATT

INSULATION FACING

EXIST'G. METAL

WALL PANEL

EXIST'G. PEMB INSUL.

FILL GIRT CAVITY W/

BATT INSULATION

EXIST'G. CONCRETE

SLAB

FILL GIRT CAVITY W/

BATT INSULATION

INSULATION FACING

PROVIDE FRAMING AT

NEW OPENING

HEAD

JAMB

MTL. STUD SYSTEM

HEADER FRAMING

5/8" GYPSUM BOARD

UNFACED SOUND BATT

HOLLOW METAL FRAME

DOOR, SEE SCHEDULE

CAULK EACH SIDE, CONT.

5/8" GYPSUM BOARD

DOUBLE STEEL STUDS

UNFACED SOUND BATT

HOLLOW METAL

FRAME

DOOR, SEE SCHEDULE

CAULK EACH SIDE,

CONT.

VARIES

VARIES

SEE NOTE BELOW

SEE NOTE BELOW

NOTE: PLASTIC WALL PANELS OVER

GYP. BD. AT DOOR #2, #4, AND #5.

PANEL INSTALLER SHALL CAULK

PERIMETER OF DOOR FRAMES

AFTER PANEL INSTALLATION.

CREW ROOM

MAINT. BAY

A102

OFFICE

OFFICE

OFFICE

CORRIDOR

TOILET

A102

A102 6

1 1 1

3 3 3

A104

HEAD

METAL WALL PANEL

PEMB THERMAL

INSUL. SYSTEM

ALUM. WINDOW UNIT "B"

CAULK EACH SIDE,

CONT.

PEMB WALL GIRT

PANEL CLOSURE STRIP

PEMB HEADER TRIM

PEMB JAMB FRAME

JAMB

PEMB JAMB FRAME

PANEL CLOSURE

STRIP

PEMB SILL TRIM

PEMB JAMB TRIM

SILL

PEMB CHANNEL FRAME

THERMAL BLOCK

THERMAL BLOCK

3 1/4" 4 3/4"

3 1/4" 4 3/4"

METAL WALL PANEL

PEMB THERMAL

INSUL. SYSTEM

ALUM. WINDOW UNIT "B"

CAULK EACH SIDE,

CONT.

THERMAL BLOCK

ALUM. WINDOW UNIT "B"

PANEL CLOSURE STRIP

PEMB SILL TRIM

CAULK EACH SIDE,

CONT.

THERMAL BLOCK

METAL WALL PANEL

PEMB THERMAL INSUL.

SYSTEM

PEMB

TRIM

PEMB

TRIM

PEMB

TRIM

A

R C

H I T E C

T

D A

V

I D

M. SAM

O K

A R

K

E N T U C K

Y

R

EG ISTERED

OF

NO.

COMMONWEALTH

WWW.CLOTFELTER-SAMOKAR.COM

REVISION HISTORY OF THIS DRAWING

DRAWING NO.

228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605

AS-BUILT DATE

DECA LOG #

DESCRIPTION OF REVISIONS DATE

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

A & E FILE NO.

DRAWN BY

CHECKED BY

PHASE

RTA DATE

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

ACCOUNT NO.

DRAWING DATE

KYTC MAINTENANCE FACILITY MADISONVILLE, KENTUCKY

/1

/2

:2 :3

P

M

DMS

03/27/25

AHH

SCHEDULES AND DETAILS

A103

C

609-C940-Z001-A78

03/28/25

SCALE: 3/8" = 1'-0"

WINDOW ELEVATIONS

SCALE: 1" = 1'-0"

SECURITY GRILL DETAIL

SCALE:

DETAIL

A103 1 1/2" = 1'-0"

D

SCALE:

DETAIL

A103 1 1/2" = 1'-0"

E

SCALE:

DETAIL

A103 3/4" = 1'-0"

G

SCALE:

DETAIL

A103 1 1/2" = 1'-0"

B

SCALE:

DETAIL

A103 1 1/2" = 1'-0"

A

SCALE:

DETAIL

A103 1 1/2" = 1'-0"

C

SCALE:

DETAIL

A103 1/8" = 1'-0"

SHEET NOTES

1 2x2 ACOUSTICAL TILE CEILING SYSTEM @ 9'-0"

ABOVE FINISH FLOOR.

2 PAINTED 5/8" GYPSUM BOARD SOFFIT OVER METAL

STUD FRAMING @ 16" O.C., BOTTOM OF FINISHED

SOFFIT @ 7'-0" +/- ABOVE FINISH FLOOR.

3 ALUMINUM CANOPY SYSTEM - REFER TO DETAIL

2/A104.

4 SLOPED TOP LOCKER SYSTEM BELOW.

5 EXTEND METAL STUD WALL AND INSULATION UP TO

UNDERSIDE OF ROOF STRUCTURE.

SCALE:

DETAIL

A103 1 1/2" = 1'-0"

F

5/8" GYP. BD. OVER

V.B. ON 8" MTL. STUDS

@ 16" O.C.

UNFACED BATT

INSULATION

EXIST'G. CONCRETE SLAB

5/8" METAL HAT

CHANNEL

S.A.T. CEILING SYSTEM

CEILING 9'-0"

UNFACED BATT

INSULATION

NEW CONCRETE

CURB

BASE, SEE

SCHEDULE

WALL EXTENDS TO

UNDERSIDE OF

ROOF DECK ABOVE

JOIST BRG. 10'-0"

METAL LINER PANEL

SILL FLASHING

METAL LINER

PANEL - TO BE

8'-8" A.F.F.

LINER PANEL 8'-8"

PROVIDE 3/4" PLY-

WOOD

SUBSTRATE

SHEATHING FULL

HEIGHT AND

WIDTH METAL

LINER PANELS,

ANCHOR TO

METAL STUD

PARTITION

9 7/8"

1/2"

5/8" GYP BOARD

E

X

IS

T 'G

G

IR

T

S A

B O

V E

EXIST'G. PEMB WALL PANEL

EXIST'G. PEMB THERMAL

INSUL. SYSTEM

5/8" GYP. BD. EACH

SIDE OVER 3 5/8" MTL.

STUDS @ 16" O.C.

UNFACED SOUND BATT

EXIST'G. PEMB

RIGID FRAME

8" COLD-ROLLED STEEL

CHANNEL SEGMENTS FROM

FLOOR TO 12'-0"+/-, ANCHOR

TO GIRTS WITH CLIP ANGLE

1'-0 1/2"

/8

11 1/4"

MAINT. BAY

EXIST'G. FIN. FLOOR

ELEV. = 0'-0"

OWNER PROVIDED

LOCKERS

PROVIDE LT. GA.

BRACING TO EXIST'G.

PURLINS, SEE J/A102

OFFICE

C

A

STEEL PIPE BOLLARD,

SEE DETAIL ON SHEET

G001

EXIST'G. HVAC

UNIT TO REMAIN

EXIST'G. GUTTER /

D.S. TO REMAIN, TYP.

A A A

NEW PRE-FIN. MTL.

CANOPY

NEW PRE-FIN. MTL.

CANOPY

NEW PRE-FIN. MTL.

CANOPY

EXIST'G. HVAC

UNIT TO REMAIN

C C

(F

.V

(F

.V

EYE

WASH

MOP

SINK

SPLASH PANEL - 8'-0"T x 8'-0"W

FRP PANEL OVER 3/4" PLY

T.O. CURB

GYPSUM BOARD

A103

G

METAL LINER PANEL

METAL LINER PANEL

METAL LINER PANEL

8'-0"

A104

FRP PANEL AT WING WALLS, ALL (3) SIDES -

8'-0"T PLASTIC PANEL OVER 3/4" PLY. TRIM AS

REQ. BETWEEN LINER PANEL AND FRP PANELS.

FRP PANEL AT WING WALLS, ALL (3) SIDES - 8'-0"T

PLASTIC PANEL OVER 3/4" PLY. TRIM AS REQ.

BETWEEN LINER PANEL AND FRP PANELS.

METAL LINER PANEL

CORNER TRIM

B.O. CANOPY

ELEV. = 8'-0"

PRE-FINISHED ALUM. FLAT

BOTTOM DECKING

PRE-FINISHED METAL LINER PANEL

HANGER ROD ASSEMBLY

PRE-FINISHED EXTRUDED

ALUM. GUTTER / FASCIA

THREADED ADJUSTMENT ROD

WALL FLASHING, BY CANOPY SUPPLIER,

COLOR SHALL MATCH CANOPY COLOR

PRE-FINISHED METAL SILL

TRIM BY PEMB SUPPLIER

PANEL CLOSURE STRIP

NOTE: STACKED WALL PANELS ONLY

OCCUR AT CANOPY LOCATIONS.

CANOPY SUPPORT

FRAMING BY PEMB

SUPPLIER

PVC PIPE SPACER SLEEVES

ALUM. CANOPY SUPPORT BEAM

BASIS OF DESIGN, MAPES

"SUPER LUMIDECK HANGER

ROD CANOPY"

HOLLOW METAL DOOR

AND FRAME, SEE

SCHEDULE

PRE-FINISHED METAL

WALL PANEL

PRE-FINISHED METAL WALL PANEL

PRE-FINISHED METAL HEAD

TRIM

PERIMETER SEALANT, EACH

SIDE OF FRAME

STEEL CLEVIS

THREADED ADJUSTMENT

ROD

PANEL CLOSURE STRIP

PRE-FINISHED METAL JAMB TRIM

8" BY-PASS GIRT

CANOPY MANUF. STANDARD

CONNECTION, THRU THREADED ROD

W/ BACKING PLATE. PROVIDE PVC

PIPE SPACER SLEEVES FULL DEPTH

OF PANEL AND CHANNEL SUPPORT

PROVIDE PERIMETER SEALANT AROUND

EACH FACE PLATE OF HANGER ROD

ASSEMBLY

PVC PIPE SPACER SLEEVES

PRE-FINISHED METAL HEAD TRIM

CANOPY SCUPPER

BEYOND

A104

A104

C C C C

(F

.V

(F

.V

(F

.V

(F

.V

NEW PRE-FIN. MTL.

CANOPY

EXIST'G. HVAC

UNIT TO REMAIN

EXIST'G. HVAC

UNIT TO REMAIN

F.R.P. PANEL SYSTEM

NEW CONCRETE CURB

EXIST'G. CONCRETE SLAB

PANEL SYSTEM SEALANT

PANEL SYSTEM END CAP

PAINTED GYP. BD.

BASE, SEE SCHEDULE

MTL. STUD WALL

UNFACED SOUND BATT

5/8" MTL. HAT

CHANNEL

A

R C

H I T E C

T

D A

V

I D

M. SAM

O K

A R

K

E N T U C K

Y

R

EG ISTERED

OF

NO.

COMMONWEALTH

WWW.CLOTFELTER-SAMOKAR.COM

REVISION HISTORY OF THIS DRAWING

DRAWING NO.

228 E. REYNOLDS RD., SUITE ONE, LEXINGTON, KY 40517 / PH. 859.273.3700 / FAX 859.271.6605

AS-BUILT DATE

DECA LOG #

DESCRIPTION OF REVISIONS DATE

DESCRIPTION OF REVISIONS DATE

DRAWING INFORMATION

A & E FILE NO.

DRAWN BY

CHECKED BY

PHASE

RTA DATE

COMMONWEALTH OF KENTUCKY

FINANCE AND ADMINISTRATION CABINET

DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES

DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION

FRANKFORT, KENTUCKY

ACCOUNT NO.

DRAWING DATE

KYTC MAINTENANCE FACILITY MADISONVILLE, KENTUCKY

/1

/2

:2 :3

P

M

DMS

03/27/25

AHH

BUILDING / WALL SECTIONS

A104

C

609-C940-Z001-A78

03/28/25

SCALE:

DETAIL

A104 1 1/2" = 1'-0"

SCALE:

DETAIL

A104 1 1/2" = 1'-0"

SCALE:

DETAIL

A104 1/8" = 1'-0"

SCALE:

BUILDING ELEVATION

A104 1/8" = 1'-0"

SCALE:

DETAIL

A104 3/8" = 1'-0"

SCALE:

DETAIL

A104 1 1/2" = 1'-0"

SCALE:

BUILDING ELEVATION

A104 1/8" = 1'-0"

SCALE:

DETAIL

A104 1 1/2" = 1'-0"

KYTC Maintenance Facility Account No.: 609-C940-Z001-A78

Interior Fit-Up – Madisonville, KY C-S Project No.:2418

TABLE OF CONTENTS 00 00 00 - 1

TABLE OF CONTENTS

DIVISION 01 - GENERAL REQUIREMENTS

01 00 00 Special Conditions

Weather Data

01 23 00 Alternates

DIVISION 03 - CONCRETE

03 30 00 Cast-In-Place Concrete

DIVISION 05 - METALS

05 12 00 Structural Steel Framing

05 40 00 Structural Cold-Formed Metal Framing

05 50 00 Metal Fabrications

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

06 10 53 Miscellaneous Rough Carpentry

06 64 00 Plastic Paneling

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

07 21 00 Thermal Insulation

07 21 30 Metal Building System Insulation

07 42.13.13 Formed Metal Wall Panels

07 26 00 Vapor Retarder Facings

07 92 00 Joint Sealants

DIVISION 08 - OPENINGS

08 11 13 Hollow Metal Doors and Frames

08 31 13 Access Doors and Frames

08 51 13 Aluminum Windows

08 56 53 Sliding Service Windows

08 71 00 Hardware

08 80 00 Glazing

DIVISION 09 - FINISHES

09 22 16 Non-Structural Metal Framing

09 29 00 Gypsum Board

09 51 13 Acoustic Panel Ceilings

09 65 13 Resilient Base and Accessories

09 91 00 Painting

DIVISION 10 - SPECIALTIES

10 11 00 Visual Display Units

10 14 23 Panel Signage

TABLE OF CONTENTS 00 00 00 - 2

10 21 13.19 Plastic Toilet Compartments

10 28 00 Toilet and Bath Accessories

10 44 16 Fire Extinguishers

10 51 13 Metal Lockers

10 70 00 Aluminum Canopies

DIVISION 11 - EQUIPMENT

11 31 00 Residential Appliances

DIVISION 12 - FURNISHINGS

12 35 30 Residential Casework

12 36 23 Plastic-Laminate-Clad Countertops

12 36 61 Solid Surfacing

DIVISION 21 – FIRE SUPPRESSION

21 00 00 General Provisions for Fire Suppression

21 05 00 Common Work Results for Fire Suppression

21 10 00 Water-Based Fire Suppression Systems

DIVISION 22 – PLUMBING

22 00 00 General Provisions for Plumbing

22 05 00 Common Work Results for Plumbing

22 05 53 Identification for Plumbing Piping and Equipment

22 07 00 Plumbing Insulation

22 11 13 Facility Water Distribution Piping

22 11 16 Domestic Water Piping

22 11 19 Domestic Water Piping Specialties

22 13 16 Sanitary Waste and Vent Piping

22 13 19 Sanitary Waste Piping Specialties

22 15 13 General-Service Compressed-Air Piping

22 40 00 Plumbing Fixtures

22 45 00 Emergency Plumbing Fixtures

22 47 00 Water Coolers

DIVISION 23 – HEATING VENTILATING AND AIR CONDITIONING

23 00 00 General Provisions for Mechanical

23 05 00 Common Work Results for Mechanical

23 05 53 Identification for Mechanical Piping and Equipment

23 06 00 Testing, Adjusting, and Balancing for HVAC (KY-DFM)

23 07 00 Mechanical Insulation

23 11 23 Facility Natural Gas Piping

23 31 13 Metal Ducts

23 33 00 Air Duct Accessories

23 34 23 HVAC Power Ventilators

TABLE OF CONTENTS 00 00 00 - 3

23 37 13 Diffusers and Grilles

23 74 13 Packaged, Outdoor, Central-Station Air-Handling Units

DIVISION 26 – ELECTRICAL

26 00 00 General Provisions for Electrical

26 05 00 Common Work Results for Electrical

26 05 19 Low-Voltage Electrical Power Conductors and Cables

26 05 26 Grounding and Bonding for Electrical Systems

26 05 29 Hangers and Supports for Electrical Systems

26 05 33 Raceway and Boxes for Electrical Systems

26 05 53 Identification for Electrical Systems

26 27 26 Wiring Devices

26 51 00 Interior Lighting

END OF TABLE OF CONTENTS

Project # 609-C940-Z001-A78

FORMED METAL WALL PANELS 074213.13 - 1

SECTION 074213.13 - FORMED METAL WALL PANELS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Metal liner panels.

2. Accessories.

1.2 ACTION SUBMITTALS

A. Product Data: Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for each type of panel and accessory.

1. Metal liner panels.

B. Shop Drawings:

1. Include fabrication and installation layouts of metal panels; details of edge conditions, joints, panel profiles, corners, anchorages, attachment system, trim, flashings, closures, and accessories; and special details.

2. Accessories: Include details of the flashing, trim, and anchorage systems, at a scale of not less than 1-1/2 inches per 12 inches.

C. Samples for Verification: For each type of exposed finish, prepared on Samples of size indicated below:

1. Metal Panels: 12 inches long by actual panel width. Include fasteners, closures, and other metal panel accessories.

1.3 INFORMATIONAL SUBMITTALS

A. Qualification Data: For Installer.

B. Product Test Reports: For exposed-fastener, lap-seam metal wall panels and metal liner panels, for tests performed by a qualified testing agency.

C. Sample Warranties: For special warranties.

1.4 CLOSEOUT SUBMITTALS

A. Maintenance Data: For metal panels to include in maintenance manuals.

FORMED METAL WALL PANELS 074213.13 - 2

1.5 QUALITY ASSURANCE

A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Deliver components, metal panels, and other manufactured items so as not to be damaged or deformed. Package metal panels for protection during transportation and handling.

B. Unload, store, and erect metal panels in a manner to prevent bending, warping, twisting, and surface damage.

C. Stack metal panels horizontally on platforms or pallets, covered with suitable weathertight and ventilated covering. Store metal panels to ensure dryness, with positive slope for drainage of water. Do not store metal panels in contact with other materials that might cause staining, denting, or other surface damage.

D. Retain strippable protective covering on metal panels during installation.

1.7 FIELD CONDITIONS

A. Weather Limitations: Proceed with installation only when existing and forecasted weather conditions permit assembly of metal panels to be performed according to manufacturers' written instructions and warranty requirements.

1.8 COORDINATION

A. Coordinate metal panel installation with rain drainage work, flashing, trim, construction of soffits, and other adjoining work to provide a leakproof, secure, and noncorrosive installation.

1.9 WARRANTY

A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of metal panel systems that fail in materials or workmanship within specified warranty period.

1. Failures include, but are not limited to, the following:

a. Structural failures including rupturing, cracking, or puncturing.

b. Deterioration of metals and other materials beyond normal weathering.

2. Warranty Period: Two years from date of Substantial Completion.

FORMED METAL WALL PANELS 074213.13 - 3

B. Special Warranty on Panel Finishes: Manufacturer's standard form in which manufacturer agrees to repair finish or replace metal panels that show evidence of deterioration of factory-applied finishes within specified warranty period.

1. Exposed Panel Finish: Deterioration includes, but is not limited to, the following:

a. Color fading more than 5 Delta E units when tested according to

ASTM D2244.

b. Chalking in excess of a No. 8 rating when tested according to ASTM D4214.

c. Cracking, checking, peeling, or failure of paint to adhere to bare metal.

2. Finish Warranty Period: 20 years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 METAL LINER PANELS

A. Provide factory-formed metal liner panels designed for interior side walls and field assembled by lapping and interconnecting side edges of adjacent panels and mechanically attaching through panel to supports using concealed fasteners in side laps.

Include accessories required for a complete installation.

B. Metal Liner Panels: Formed with raised, trapezoidal major ribs and intermediate stiffening ribs symmetrically spaced between major ribs. Match existing liner panels profile.

1. Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. ATAS International, Inc.

b. Centria, a Nucor Company.

c. Englert, Inc.

d. Fabral, a brand of Flack Global Metals.

e. MBCI, a division of NCI Group..

f. Metal Sales Manufacturing Corporation.

2. Metallic-Coated Steel Sheet: Zinc-coated (galvanized) steel sheet complying with ASTM A653/A653M, G90 coating designation, or aluminum-zinc alloy-coated steel sheet complying with ASTM A792/A792M, Class AZ50 coating designation;

structural quality. Prepainted by the coil-coating process to comply with

ASTM A755/A755M.

a. Nominal Thickness: 26 gauge.

b. Exterior Finish: Siliconized polyester.

c. Color: As selected by Architect from manufacturer's full range.

3. Major-Rib Spacing: 12 inches o.c.

4. Panel Coverage: 36 inches .

FORMED METAL WALL PANELS 074213.13 - 4

5. Panel Height: 1.25 inches +/-, match existing.

2.2 MISCELLANEOUS MATERIALS

A. Miscellaneous Metal Subframing and Furring: ASTM C645, cold-formed, metallic-coated steel sheet, ASTM A653/A653M, G90 (Z275) hot-dip galvanized coating designation or ASTM A792/A792M, Class AZ50 (Class AZM150) aluminum-zinc-alloy coating designation unless otherwise indicated. Provide manufacturer's standard sections as required for support and alignment of metal panel system.

B. Panel Accessories: Provide components required for a complete, weathertight panel system including trim, copings, fasciae, mullions, sills, corner units, clips, flashings, sealants, gaskets, fillers, closure strips, and similar items. Match material and finish of metal panels unless otherwise indicated.

1. Closures: Provide closures at eaves and rakes, fabricated of same metal as metal panels.

2. Backing Plates: Provide metal backing plates at panel end splices, fabricated from material recommended by manufacturer.

3. Closure Strips: Closed-cell, expanded, cellular, rubber or crosslinked, polyolefin-foam or closed-cell laminated polyethylene; minimum 1-inch- (25-mm-) thick, flexible closure strips; cut or premolded to match metal panel profile. Provide closure strips where indicated or necessary to ensure weathertight construction.

C. Flashing and Trim: Provide flashing and trim formed from same material as metal panels as required to seal against weather and to provide finished appearance. Locations include, but are not limited to, bases, drips, sills, jambs, corners, endwalls, framed openings, rakes, fasciae, parapet caps, soffits, reveals, and fillers. Finish flashing and trim with same finish system as adjacent metal panels.

D. Pipe Flashing: Premolded, EPDM pipe collar with flexible aluminum ring bonded to base.

E. Panel Fasteners: Self-tapping screws designed to withstand design loads. Provide exposed fasteners with heads matching color of metal panels by means of plastic caps or factory-applied coating. Provide EPDM or PVC sealing washers for exposed fasteners.

F. Panel Sealants: Provide sealant type recommended by manufacturer that are compatible with panel materials, are nonstaining, and do not damage panel finish.

1. Sealant Tape: Pressure-sensitive, 100 percent solids, gray polyisobutylene compound sealant tape with release-paper backing. Provide permanently elastic, nonsag, nontoxic, nonstaining tape 1/2 inch (13 mm) wide and 1/8 inch (3 mm) thick.

2. Joint Sealant: ASTM C920; elastomeric polyurethane or silicone sealant; of type, grade, class, and use classifications required to seal joints in metal panels and remain weathertight; and as recommended in writing by metal panel manufacturer.

3. Butyl-Rubber-Based, Solvent-Release Sealant: ASTM C1311.

FORMED METAL WALL PANELS 074213.13 - 5

2.3 FABRICATION

A. Fabricate and finish metal panels and accessories at the factory, by manufacturer's standard procedures and processes, as necessary to fulfill indicated performance requirements demonstrated by laboratory testing. Comply with indicated profiles and with dimensional and structural requirements.

B. Provide panel profile, including major ribs and intermediate stiffening ribs, if any, for full length of panel.

C. Fabricate metal panel joints with factory-installed captive gaskets or separator strips that provide a weathertight seal and prevent metal-to-metal contact, and that minimize noise from movements.

D. Sheet Metal Flashing and Trim: Fabricate flashing and trim to comply with manufacturer's recommendations and recommendations in SMACNA's "Architectural Sheet Metal Manual" that apply to design, dimensions, metal, and other characteristics of item indicated.

2.4 FINISHES

A. Protect mechanical and painted finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

B. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if they are within one-half of the range of approved Samples. Noticeable variations in same piece are not acceptable. Variations in appearance of other components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.

C. Steel Panels and Accessories:

1. Two-Coat Fluoropolymer: AAMA 621. Fluoropolymer finish containing not less than 70 percent polyvinylidene fluoride (PVDF) resin by weight in color coat.

Prepare, pretreat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' written instructions.

2. Siliconized Polyester: Epoxy primer and silicone-modified, polyester-enamel topcoat; with a dry film thickness of not less than 0.2 mil (0.005 mm) for primer and

0.8 mil (0.02 mm) for topcoat.

3. Concealed Finish: Apply pretreatment and manufacturer's standard white or light-colored acrylic or polyester backer finish consisting of prime coat and wash coat with a minimum total dry film thickness of 0.5 mil (0.013 mm).

FORMED METAL WALL PANELS 074213.13 - 6

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances, metal panel supports, and other conditions affecting performance of the Work.

1. Examine wall framing to verify that girts, angles, channels, studs, and other structural panel support members and anchorage have been installed within alignment tolerances required by metal wall panel manufacturer.

B. Examine roughing-in for components and systems penetrating metal panels to verify actual locations of penetrations relative to seam locations of metal panels before installation.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 PREPARATION

A. Miscellaneous Supports: Install subframing, furring, and other miscellaneous panel support members and anchorages according to ASTM C754 and metal panel manufacturer's written recommendations.

3.3 INSTALLATION OF METAL PANELS

A. Install metal panels according to manufacturer's written instructions in orientation, sizes, and locations indicated. Install panels perpendicular to supports unless otherwise indicated. Anchor metal panels and other components of the Work securely in place, with provisions for thermal and structural movement.

1. Shim or otherwise plumb substrates receiving metal panels.

2. Flash and seal metal panels at perimeter of all openings. Fasten with self-tapping screws. Do not begin installation until air- or water-resistive barriers and flashings that will be concealed by metal panels are installed.

3. Install screw fasteners in predrilled holes.

4. Locate and space fastenings in uniform vertical and horizontal alignment.

5. Install flashing and trim as metal panel work proceeds.

6. Locate panel splices over, but not attached to, structural supports. Stagger panel splices and end laps to avoid a four-panel lap splice condition.

7. Align bottoms of metal panels and fasten with blind rivets, bolts, or self-tapping screws. Fasten flashings and trim around openings and similar elements with self-tapping screws.

8. Provide weathertight escutcheons for pipe- and conduit-penetrating panels.

B. Fasteners:

FORMED METAL WALL PANELS 074213.13 - 7

1. Steel Panels: Use stainless steel fasteners for surfaces exposed to the exterior;

use galvanized-steel fasteners for surfaces exposed to the interior.

C. Metal Protection: Where dissimilar metals contact each other or corrosive substrates, protect against galvanic action as recommended in writing by metal panel manufacturer.

D. Metal Liner Panels: Install panels on interior side of gypsum board wall assembly with flush appearance on the inside.

E. Accessory Installation: Install accessories with positive anchorage to building and weathertight mounting, and provide for thermal expansion. Coordinate installation with flashings and other components.

1. Install components required for a complete metal panel system including trim, copings, corners, seam covers, flashings, sealants, gaskets, fillers, closure strips, and similar items. Provide types indicated by metal wall panel manufacturer; or, if not indicated, provide types recommended by metal panel manufacturer.

F. Flashing and Trim: Comply with performance requirements, manufacturer's written installation instructions, and SMACNA's "Architectural Sheet Metal Manual." Provide concealed fasteners where possible, and set units true to line and level as indicated.

Install work with laps, joints, and seams that are permanently watertight.

1. Install exposed flashing and trim that is without buckling and tool marks, and that is true to line and levels indicated, with exposed edges folded back to form hems.

Install sheet metal flashing and trim to fit substrates and achieve waterproof performance.

2. Expansion Provisions: Provide for thermal expansion of exposed flashing and trim.

Space movement joints at a maximum of 10 feet (3 m) with no joints allowed within 24 inches (610 mm) of corner or intersection. Where lapped expansion provisions cannot be used or would not be sufficiently waterproof, form expansion joints of intermeshing hooked flanges, not less than 1 inch (25 mm) deep, filled with mastic sealant (concealed within joints).

3.4 CLEANING AND PROTECTION

A. Remove temporary protective coverings and strippable films, if any, as metal panels are installed, unless otherwise indicated in manufacturer's written installation instructions.

On completion of metal panel installation, clean finished surfaces as recommended by metal panel manufacturer. Maintain in a clean condition during construction.

B. After metal panel installation, clear weep holes and drainage channels of obstructions, dirt, and sealant.

C. Replace metal panels that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures.

END OF SECTION 07 42 13.13

PAINTING 09 91 00 - 1

SECTION 09 91 00 - PAINTING

1.1 SUMMARY

A. This Section includes, but is not limited to, surface preparation and the application of paint systems on the following interior and exterior substrates:

1. Concrete.

2. Steel.

3. Galvanized metal.

4. Aluminum (not anodized or otherwise coated).

5. Wood.

6. Gypsum board.

1.2 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Samples for Initial Selection: For each type of topcoat product indicated.

C. Samples for Verification: For each type of paint system and in each color and gloss of topcoat indicated.

1. Submit Samples on rigid backing, 8 inches square.

2. Step coats on Samples to show each coat required for system.

3. Label each coat of each Sample.

4. Label each Sample for location and application area.

D. Product List: For each product indicated, include the following:

1. Cross-reference to paint system and locations of application areas. Use same designations indicated on Drawings and in schedules.

1.3 DELIVERY, STORAGE, AND HANDLING

A. Store materials not in use in tightly covered containers in well-ventilated areas with ambient temperatures continuously maintained at not less than 45 deg F.

1. Maintain containers in clean condition, free of foreign materials and residue.

2. Remove rags and waste from storage areas daily.

1.4 EXTRA MATERIALS

A. Furnish extra materials described below that are from same production run (batch mix) as materials applied and that are packaged for storage and identified with labels describing contents.

PAINTING 09 91 00 - 2

1. Quantity: Furnish an additional 5 percent, but not less than 1 gal. of each material and color applied.

1.5 PROJECT CONDITIONS

A. Apply paints only when temperature of surfaces to be painted and ambient air temperatures are between 50 and 95 deg F.

B. Do not apply paints when relative humidity exceeds 85 percent; at temperatures less than 5 deg F above the dew point; or to damp or wet surfaces.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Basis-of-Design: Subject to compliance with requirements, provide Sherwin Williams or comparable products by one of the following:

1. Benjamin Moore & Co.

2. Coronado Paint.

3. Porter Paints.

4. PPG Architectural Finishes, Inc.

5. Farrell-Calhoun

2.2 PAINT, GENERAL

A. Material Compatibility:

1. Provide materials for use within each paint system that are compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.

B. Colors:

1. As selected by Architect from manufacturer's full range.

2. The selection of colors and placement of colors for interior painted surfaces shall be unlimited, allowing for accent walls in rooms and allowing for selection of ultra deep tones.

2.3 HIGH PERFORMANCE PRIMERS

A. Concrete and Masonry Primer: Premium quality, waterborne acrylic, direct-to-metal/masonry primer.

1. (P-4) Sherwin Williams DTM Acrylic Primer Finish B66W1.

PAINTING 09 91 00 - 3

B. Concrete and Masonry Primer: High performance, two-package, chemically cured, waterborne epoxy primer.

1. (P-5) Not Used.

2.4 PRIMERS/SEALERS

A. Interior Latex Primer: Factory formulated professional quality latex primer.

1. (P-6) Sherwin Williams ProMar 400 Zero VOC Interior Latex Primer B28 Series.

B. Interior/Exterior Multi-Purpose Primer: Factory formulated, professional quality acrylic primer.

1. (P-7) Sherwin Williams Mult-Purpose Latex Primer B51 W8020.

C. Exterior Primer: Factory formulated acrylic multi-purpose primer.

1. (P-8) Sherwin Williams Exterior Latex Wood Primer B42 W8041.

2.5 METAL PRIMERS

A. Ferrous Metal Primer: Factory formulated, rust inhibitive, quick drying alkyd type metal primer.

1. (P-9) Sherwin Williams Kem Kromik Universal Alkyd Primer B50NZ6.

B. Galvanized Metal Primer: Factory formulated, flexible, high-adherent alkyd type galvanized metal primer.

1. (P-10) Sherwin Williams Pro Industrial Pro Cryl Universal Acrylic Primer B66W310.

C. Ferrous/Galvanized Metal Primer: High performance, chemically cured, rust-inhibitive epoxy metal primer.

1. (P-11) Not Used.

2.6 WOOD PRIMERS

A. Interior Wood Primer: Factory formulated professional quality solvent based wood primer.

1. (P-12) Sherwin Williams ProBlock Interior Oil Based Primer B79W8810.

B. Exterior Wood Primer: Factory formulated solvent based exterior primer.

1. (P-13) Not Used.

PAINTING 09 91 00 - 4

2.7 LATEX PAINTS

A. Interior Latex (Flat): Factory formulated professional quality interior flat paint.

1. (F-1) Sherwin Williams ProMar 400 Interior Latex Flat B30W400.

B. Interior Latex (Eggshell): Factory formulated professional quality interior wall and trim paint.

1. (F-2) Sherwin Williams ProMar 400 Interior Latex Eg-Shel B200W4651.

C. Interior Latex (Semigloss): Factory formulated professional quality interior wall and trim paint.

1. (F-3) Sherwin Williams ProMar 400 Interior Latex Semi-Gloss B31W4451.

D. Exterior (Satin): Superior performance, high quality acrylic exterior finish.

1. (F-4) Sherwin Williams Super Paint Exterior Latex Satin A89W1151.

E. Exterior (Semigloss): Superior performance, high quality acrylic exterior finish.

1. (F-5) Sherwin Williams Super Paint Exterior Latex Gloss A84W1151.

2.8 ALKYD PAINTS

A. Interior Alkyd (Eggshell): Factory formulated professional quality interior alkyd finish for walls and trim.

1. (F-6) Sherwin Williams ProMar 400 Exterior Alkyd Eg-Shel B33W251.

B. Interior Alkyd (Semigloss): Factory formulated professional quality interior alkyd finish for walls and trim.

1. (F-7) Sherwin Williams ProMar 400 Exterior Alkyd Semi-Gloss B34W251.

C. Exterior Alkyd (Semigloss): Factory formulated professional quality exterior alkyd finish for walls and trim.

1. (F-8) Sherwin Williams ProMar 400 Exterior SWP Exterior Oil Gloss A2W528.

2.9 STAINS / VARNISHES

A. Wood Stain: Professional quality interior linseed oil resin stain.

1. (F-9) WOOD PRIDE Professional Wood Finishes. Oil-Based Wood-Finishing Semi-Transparent Stain 1700.

B. Wood Varnish, (Satin): Professional quality interior satin polyurethane finish.

PAINTING 09 91 00 - 5

1. (F-10) WOOD PRIDE Professional Wood Finishes. Polyurethane Satin Finish 1902.

C. Wood Varnish, (Gloss): Professional quality interior gloss polyurethane finish.

1. (F-11) WOOD PRIDE Professional Wood Finishes. Polyurethane Gloss Finish 1908.

2.10 DRY FOG/FALL COATINGS

A. Interior Water-based Dry Fog/Fall: Factory formulated high-hiding interior dryfall coating.

Coating shall be available in both black and tintable base.

1. (F-12) Sherwin Williams Waterborne Acrylic Dryfall B42T1/BW3.

2.11 HIGH PERFORMANCE ARCHITECTURAL COATINGS

A. Waterborne epoxy coating: High performance, two-part waterborne semi-gloss epoxy coating.

1. (F-13) Sherwin Williams Waterbased Tile Clad Epoxy B73W111.

B. Epoxy coating: High solids, high performance, two-part epoxy coating.

1. (F-14) Sherwin Williams Resuflor 3746 High Performance Epoxy, silver gray.

When used on concrete floor slab, provide 40/60 mesh sand additive.

C. Acrylic Coating: Premium quality single-part waterborne acrylic semi-gloss high traffic enamel.

1. (F-15) Sherwin Williams Pro Industrial Zero VOC Acrylic Semi-Gloss B66W651.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates and conditions, with Applicator present, for compliance with requirements for maximum moisture content and other conditions affecting performance of work.

B. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter as follows:

1. Concrete: 12 percent.

2. Gypsum Board: 12 percent.

PAINTING 09 91 00 - 6

C. Verify suitability of substrates, including surface conditions and compatibility with existing finishes and primers.

D. Begin coating application only after unsatisfactory conditions have been corrected and surfaces are dry.

1. Beginning coating application constitutes Contractor's acceptance of substrates and conditions.

3.2 PREPARATION

A. Comply with manufacturer's written instructions and recommendations in "MPI Architectural Painting Specification Manual" applicable to substrates indicated.

B. Remove plates, machined surfaces, and similar items already in place that are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting.

1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection if any.

2. Do not paint over labels of independent testing agencies or equipment name, identification, performance rating, or nomenclature plates.

C. Clean substrates of substances that could impair bond of paints, including dirt, oil, grease, and incompatible paints and encapsulants.

1. Remove incompatible primers and reprime substrate with compatible primers as required to produce paint systems indicated.

D. Concrete Substrates: Remove release agents, curing compounds, efflorescence, and chalk. Do not paint surfaces if moisture content or alkalinity of surfaces to be painted exceeds that permitted in manufacturer's written instructions. Concrete slabs are existing; examine and treat/prepare per paint manufacturer's recommendations.

E. Steel Substrates: Remove rust and loose mill scale. Clean using methods recommended in writing by paint manufacturer.

F. Galvanized-Metal Substrates: Remove grease and oil residue from galvanized sheet metal fabricated from coil stock by mechanical methods to produce clean, lightly etched surfaces that promote adhesion of subsequently applied paints.

G. Aluminum Substrates: Remove surface oxidation.

H. Gypsum Board Substrates: Do not begin paint application until finishing compound is dry and sanded smooth.

I. Cotton or Canvas Insulation Covering Substrates: Remove dust, dirt, and other foreign material that might impair bond of paints to substrates.

PAINTING 09 91 00 - 7

3.3 APPLICATION

A. Apply paints according to manufacturer's written instructions.

1. Use applicators and techniques suited for paint and substrate indicated.

2. Paint surfaces behind movable equipment and furniture same as similar exposed surfaces. Before final installation, paint surfaces behind permanently fixed equipment or furniture with prime coat only.

3. Paint front and backsides of access panels, removable or hinged covers, and similar hinged items to match exposed surfaces.

4. Do not use paint over dirt, rust, scale, grease, moisture, scuffed surfaces or conditions detrimental to formation of a durable paint film.

5. Provide finish coats that are compatible with primers used.

B. If undercoats or other conditions show through topcoat, apply additional coats until cured film has a uniform paint finish, color, and appearance.

C. Apply paints to produce surface films without cloudiness, spotting, holidays, laps, brush marks, roller tracking, runs, sags, ropiness, or other surface imperfections. Cut in sharp lines and color breaks.

D. The number and coats and film thickness are the same regardless of application method.

Do not apply succeeding coats until previous coat has cured as required by the manufacturer.

E. Minimum coating thickness: Apply paint materials no thinner than the manufacturer’s recommended spreading rate to achieve dry film thickness indicated.

F. Painting Mechanical and Electrical Work: Paint items exposed in equipment rooms and occupied spaces including, but not limited to, the following:

1. Mechanical Work:

a. Uninsulated metal piping.

b. Uninsulated plastic piping.

c. Pipe hangers and supports.

d. Tanks that do not have factory-applied final finishes.

e. Visible portions of internal surfaces of metal ducts, without liner, behind air inlets and outlets.

f. Duct, equipment, and pipe insulation having cotton or canvas insulation covering or other paintable jacket material.

g. Mechanical equipment that is indicated to have a factory-primed finish for field painting.

2. Electrical Work:

a. Conduit.

b. Electrical equipment that is indicated to have a factory-primed finish for field painting.

PAINTING 09 91 00 - 8

3.4 CLEANING AND PROTECTION

A. At end of each workday, remove rubbish, empty cans, rags, and other discarded materials from Project site.

B. After completing paint application, clean spattered surfaces. Remove spattered paints by washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces.

C. Protect work of other trades against damage from paint application. Correct damage to work of other trades by cleaning, repairing, replacing, and refinishing, as approved by Architect, and leave in an undamaged condition.

D. At completion of construction activities of other trades, touch up and restore damaged or defaced painted surfaces.

3.5 INTERIOR PAINTING SCHEDULE

A. Concrete Substrates, Traffic Surfaces:

1. Concrete Floors: High Performance Architectural Coating System.

a. First Coat: F-14.

b. Topcoat: F-14.

B. Steel Substrates:

Note: Painting of PEMB steel elements is NOT required.

1. Structural Steel (exposed): Alkyd System.

a. Prime Coat: P-9.

b. Intermediate Coat: F-7.

c. Topcoat: F-7.

2. Miscellaneous Ferrous Metals and Sheet Metal: Alkyd System.

a. Prime Coat: P-9.

b. Intermediate Coat: F-7.

c. Topcoat: Interior latex F-7.

C. Galvanized-Metal Substrates:

1. Hollow Metal Doors/Frames and Guardrails/Handrails: Alkyd System.

a. Prime Coat: P-10.

b. Intermediate Coat: F-7.

c. Topcoat: F-7.

PAINTING 09 91 00 - 9

2. Structural Steel (exposed): Alkyd System.

a. Prime Coat: P-10.

b. Intermediate Coat: F-7.

c. Topcoat: F-7.

3. Miscellaneous Ferrous Metals and Sheet Metal: Alkyd System.

a. Prime Coat: P-10.

b. Intermediate Coat: F-7.

c. Topcoat: Interior latex F-7.

D. Wood Substrates: Including interior finish carpentry and painted panel products.

1. Alkyd System.

a. Prime Coat: P-12.

b. Intermediate Coat: F-7.

c. Topcoat: F-7.

E. Gypsum Board Substrates:

1. Ceilings: High Performance Architectural Coating System (Acrylic).

a. Prime Coat: P-6.

b. Intermediate Coat: F-15.

c. Topcoat: F-15.

2. Walls: Latex Eggshell System.

a. Prime Coat: P-6.

b. Intermediate Coat: F-2.

c. Topcoat: F-2

3. Walls: High Performance Architectural Coating System (Acrylic).

a. Prime Coat: P-6.

b. Intermediate Coat: F-15.

c. Topcoat: F-15.

F. Mechanical and Electrical Substrates: Including piping, ducts, conduits and hangars.

1. Galvanized Piping: Alkyd System.

a. Prime Coat: P-10.

b. Intermediate Coat: F-7.

PAINTING 09 91 00 - 10

2. Ductwork/Sheet Metal (exposed):

a. Prime Coat: F-12.

b. Topcoat: F-12.

3. Grilles / Registers / Diffusers:

a. Prime Coat: Factory Prime Coat

b. Intermediate Coat: F-7

3.6 EXTERIOR PAINTING SCHEDULE

A. Steel Substrates:

1. Miscellaneous Ferrous Metals and Sheet Metal: Alkyd System.

a. Prime Coat: P-9.

b. Intermediate Coat: F-8.

c. Topcoat: F-8.

B. Galvanized-Metal Substrates:

1. Hollow Metal Doors/Frames and Guardrails/Handrails: Alkyd System.

a. Prime Coat: P-10.

b. Intermediate Coat: F-8.

c. Topcoat: F-8.

2. Miscellaneous Ferrous Metals and Sheet Metal: Alkyd System.

a. Prime Coat: P-10.

b. Intermediate Coat: F-8.

c. Topcoat: F-8.

END OF SECTION

Addendum Three
Addendum 3 (1)
2418 Hopkins County Maintenance Fit Up_ADD 3
Sheets
A101 - BUILDING FLOOR PLAN
A103 - SCHEDULES AND DETAILS
A104 - BUILDING / WALL SECTIONS
C940 - Project Manual Table of Contents (1)
07 42 13.13 - Formed Metal Wall Panels
09 91 00 - Painting

File details come from the government source that posted it. Updated .