Addendum Three.pdf
PDF 1 MB Posted
- Attached to
- RFB-30-25 KCTCS Switchgear Replacement
- Solicitation number
- RFB 785 2500000019 5
- Issued by
- Cumberland County, Kentucky
About this file
This is Addendum Three to an Invitation to Bid (RFB-30-25) issued by the Commonwealth of Kentucky Department for Facilities and Support Services, Division of Engineering and Contract Administration, for switchgear replacement at Owensboro Community & Technical College (KCTCS) Downtown Campus in Owensboro, Kentucky. The project, identified as Account No. 470-CB72-OC33-00 and A/E Project No. 2401-116, involves comprehensive electrical work including replacement of the main distribution switchboard, installation of new padmount transformers, emergency power generation, fire alarm system modifications, and associated electrical infrastructure upgrades. The addendum, dated August 15, 2024, incorporates revised electrical drawings (E1.0 Rev 2 and E2.1 Rev 1) that clarify fixture type requirements, provide electrical legends with data cable specifications, and identify specific circuit breaker locations (CB-KLEFT in Passage Room 13 and CB-XVET). The project requires coordination with multiple trades, utility companies, and specialized subcontractors, including Innovative Fire & Security Solutions for fire alarm modifications and Owensboro Municipal Utilities (OMU) for utility work.
The contractor must include allowances of $5,000.00 for fire alarm system work performed by Innovative Fire & Security Solutions and $12,300.00 for work performed by OMU, with overhead and profit to be added separately. All costs associated with permits, state inspections, utility disruptions, power outages, and overtime labor must be included in the bid price. Power outages are limited to after normal business hours (8:00 PM to 6:00 AM Monday through Thursday) and weekends (Friday after 4:30 PM through Sunday 11:59 PM). The contractor is responsible for demolition and removal of existing Federal Pacific distribution equipment, delivery to on-site storage as directed, installation of fire alarm devices and associated cabling, all cutting and patching to meet existing fire ratings, and coordination of utility work with OMU and the owner/using agency (KCTCS-OCTC).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMONWEALTH OF KENTUCKY
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
INVITATION TO BID NO: RFB-30-25
FOR: Switchgear Replacement Owensboro Community & Technical College Downtown Campus-KCTCS Owensboro, Kentucky
DATE: August 16, 2024
RFB-785-2500000019
ADDENDUM NO. Three (3)
BIDDER SHALL CONFORM TO THE FOLLOWING CHANGES AS SAME SHALL BECOME BINDING
UPON THE CONTRACT TO BE ISSUED IN RESPONSE TO THIS INVITATION TO BID.
Item 1: Refer to addendum to be distributed by Lynn Imaging for all additions, deletions, and/or changes to specifications and/or drawings.
END OF ADDENDUM
Invitation to Bid No. RFB-30-25 For: Switchgear Replacement Owensboro Community & Technical College Downtown Campus-KCTCS
Susan Ward, Statewide Procurement Analyst II Division of Engineering and Contract Administration
August 15, 2024
Mr. Brian Cottongim Kentucky Finance and Administration Cabinet Department for Facilities & Support Services
Bush Building
403 Wapping Street Frankfort, Kentucky 40601
Re: Switchgear Replacement -Owensboro Community & Technical College – Downtown Campus -
KCTCS
Request for Bid: RFB-30-25
Account No.: 470-CB72-OC33-00 A/E Project no.: 2401-116
Dear Mr. Cottongim:
The following items need to be included in an addendum to the Switchgear Replacement - Owensboro Community & Technical College Downtown Campus – KCTCS Project.
Addendum Items:
1. Refer to attached Revised Drawing E1.0 Rev 2 Site Electrical Plan, Lighting Fixture Schedule.
a. Clarified Fixture type “F3D” requirements.
2. Refer to attached Revised Drawing E1.0 Rev 2 Site Electrical Plan, Electrical Legend.
a. Added an electrical legend which clarifies fixture symbols used and quantities of data cables required to be provided to data outlets.
3. Refer to attached Revised Drawing E2.1 Rev 1 Electrical Plan First Floor, Passage Room 13.
a. Identified location and requirements for Circuit Breaker “CB-KLEFT”.
4. Refer to attached Revised Drawing E2.1 Rev 1 Electrical Plan First Floor, Enlarged Elec Plan – Mezz Rm 23.
a. Identified location and requirements for Circuit Breaker “CB-XVET”.
Sincerely, HAFER
Matt Brockman, P.E., LEED® AP
Attachments:
(1) Revised Drawing E1.0 Rev 2 Site Electrical Plan
(2) Revised Drawing E2.1 Rev 1 Electrical Plan – First Floor
G1. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ALL DEMOLITION AND
NEW CONSTRUCTION REQUIREMENTS WITH THE WORK OF ALL OTHER TRADES
INVOLVED ON THIS PROJECT.
G2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED CUTTING AND
PATCHING TO PROVIDE DEMOLITION AND NEW CONSTRUCTION REQUIREMENTS.
ALL INSTALLATION AND PATCHING SHALL MEET THE FIRE RATINGS OF THE
EXISTING CEILING/WALL/FLOOR SYSTEMS.
G3. PERMITS & STATE INSPECTION COSTS. ALL COSTS ASSOCIATED WITH
OBTAINING THE REQUIRED PERMITS AND INSPECTIONS FOR THE NEW
CONSTRUCTION INSTALLATION SHALL BE INCLUDED IN THE ELECTRICAL
CONTRACTOR'S BID PRICE.
G4. FIRE ALARM SYSTEM MODIFICATIONS. THE CONTRACTOR SHALL PROVIDE
THE SERVICES OF INNOVATIVE FIRE & SECURITY SOLUTIONS, FOR ALL WORK
ASSOCIATED WITH MODIFICATIONS TO THE FIRE ALARM SYSTEM.
ROBERT HORTON
812-568-4977
RHORTON@IFSS-EVV.COM.
G5. ALLOWANCE FOR THE WORK PERFORMED BY INNOVATIVE FIRE &
SECURITY SOLUTIONS. THE CONTRACTOR SHALL INCLUDE IN THEIR BID PRICE A
TOTAL ALLOWANCE COST OF $5,000.00 FOR THE WORK PERFORMED BY
INNOVATIVE FIRE & SECURITY SOLUTIONS (IFSS). THE ALLOWANCE DOES NOT
INCLUDE ANY OVERHEAD AND PROFIT THE BIDDING CONTRACTOR NEEDS TO
ADD ON TOP OF THE ALLOWANCE. THE FOLLOWING IS A CLARIFICATION OF THE
SCOPE WHICH IS INCLUDED IN THE ALLOWANCE AMOUNT.
G5.1. IFSS SHALL FURNISH TO THE ELECTRICAL CONTRACTOR ALL
REQUIRED SMOKE DETECTORS, HEAT DETECTORS, ADDRESSABLE
RELAYS AND MONITOR MODULES AND AUDIO & VISUAL ALARM
INDICATING DEVICES REQUIRED TO MEET THE REQUIREMENTS OF
THE CONTRACT DRAWINGS AND SPECIFICATIONS.
G5.2. IFSS SHALL FURNISH ALL LABOR REQUIRED TO REMOVE DEMOED
FIRE ALARM EQUIPMENT FROM THE FIRE ALARM SYSTEM PANEL
PROGRAMMING.
G5.3. IFSS SHALL FURNISH ALL LABOR REQUIRED TO PROGRAM FIRE
ALARM DEVICES AFTER INSTALLATION OF THE DEVICES BY THE
ELECTRICAL CONTRACTOR HAS BEEN COMPLETED.
G5.4. IFSS WILL FURNISH LABOR TO BE PRESENT FOR AND ASSIST IN THE
TESTING OF THE FIRE ALARM SYSTEM AND NEW DEVICES. THIS
TESTING SHALL OCCUR AND BE COMPLETED DURING A MAXIMUM OF
TWO SITE VISITS.
G6. THE FOLLOWING WORK BY THE ELECTRICAL CONTRACTOR SHALL NOT BE
INCLUDED IN THE ALLOWANCE COST (IDENTIFIED IN PARAGRAPH G5. ABOVE) .
THE FOLLOWING COSTS SHALL BE INCLUDED IN THE CONTRACTOR'S BID PRICE.
G6.1. THE ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIRE ALARM
SYSTEM DEVICES FURNISHED BY IFSS AS PART OF THE ALLOWANCE
COST.
G6.2. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL
REQUIRED CABLING & CONDUIT RACEWAYS TO INSTALL THE FIRE
ALARM EQUIPMENT FURNISHED BY IFSS AS PART OF THE
ALLOWANCE COST.
G6.3. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL
REQUIRED CIRCUITS BETWEEN THE FIRE ALARM SYSTEM AND
OTHER NON-FIRE ALARM SYSTEM EQUIPMENT REQUIRED FOR
CORRECT OPERATION.
G6.4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR AND
EQUIPMENT REQUIRED AND SHALL DEMO THE EXISTING FIRE ALARM
SYSTEM DEVICES AND ASSOCIATED CIRCUITS PER THE CONTRACT
DRAWINGS.
G6.5. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL
REQUIRED CABLING AND CONDUIT RACEWAYS AND SHALL
REINSTALL THE FIRE ALARM EQUIPMENT REMOVED FOR
RELOCATION DURING DEMOLITION.
G6.6. THE ELECTRICAL CONTRACTOR SHALL BE PRESENT FOR ALL
TESTING OF THE FIRE ALARM SYSTEM AND ALL REQUIRED
INTERFACES OF OTHER NON-FIRE ALARM SYSTEM EQUIPMENT
AFTER ALL INSTALLATION HAS BEEN COMPLETED. SEE ALLOWANCE
PARAGRAPH ABOVE FOR ADDITIONAL REQUIREMENTS.
G7. ALLOWANCE FOR THE WORK PERFORMED BY OWENSBORO MUNICIPAL
UTILITIES (OMU). THE CONTRACTOR SHALL INCLUDE IN THEIR BID PRICE A TOTAL
ALLOWANCE COST OF $12,300.00 FOR THE WORK PERFORMED BY OMU. THE
ALLOWANCE DOES NOT INCLUDE ANY OVERHEAD AND PROFIT THE BIDDING
CONTRACTOR NEEDS TO ADD ON TOP OF THE ALLOWANCE. COORDINATE ALL
REQUIRED WORK WITH THE UTILITY COMPANY.
G8. UTILITY DISRUPTIONS AND POWER OUTAGES. ALL COSTS ASSOCIATED
WITH UTILITY DISRUPTIONS AND POWER OUTAGES SHALL BE INCLUDED IN THE
CONTRACTOR'S BID PRICE. COSTS FOR OVERTIME (TIME AND A HALF, DOUBLE
TIME, HOLIDAY PAY, ETC.) SHALL BE INCLUDED IN THE CONTRACTOR'S BID
PRICE. ALL UTILITY AND POWER OUTAGES SHALL BE COORDINATED WITH AND
APPROVED BY THE OWNER/USING AGENCY (I.E. KCTCS-OCTC) PRIOR TO THE
NEED FOR THE POWER DISRUPTIONS. POWER DISRUPTIONS SHALL ONLY
OCCUR DURING "AFTER NORMAL BUSINESS HOURS" AND "WEEKEND" TIME
PERIODS. FOR BIDDING PURPOSES, THE CONTRACTOR SHALL ASSUME THE
FOLLOWING TIMES FOR UTILITY AND POWER DISRUPTIONS:
G8.1. WEEK DAYS (MONDAY THRU THURSDAY): 8:00PM TO 6:00AM
G8.2. WEEKENDS (FRIDAY EVENING AFTER 4:30PM THRU
SUNDAY EVENING 11:59PM):
G9. EXISTING FEDERAL PACIFIC DISTRIBUTION EQUIPMENT. THE OWNER /
USING AGENCY (KCTCS-OCTC) WANTS THE OLD REMOVED FEDERAL PACIFIC
EQUIPMENT & OVER-CURRENT PROTECTION DEVICES AFTER DISCONNECTION
AND REMOVAL. THE CONTRACTOR SHALL DELIVER THE EQUIPMENT TO AN ON-
SITE STORAGE LOCATION AS DIRECTED BY KCTCS-OCTC.
GENERAL NOTES (THIS PROJECT):
W 15TH ST
F R
E D
E R
IC
A
S T
D A
V
IE
S S
S T
NEW UTILITY COMPANY PADMOUNT TRANSFORMER.
CONTRACTOR SHALL PROVIDE CONCRETE BASE
AND SHALL STUB PRIMARY SIDE CONDUITS OUT
PAST EDGE OF BASE. SEE UTILITY TRANSFORMER
PAD BASE DETAIL, THIS SHEET, FOR ADDITIONAL
REQUIREMENTS. COORDINATE ALL REQUIREMENTS
WITH UTILITY COMPANY.
EXISTING UTILITY COMPANY
POLE WITH PRIMARY FEED FROM
OVERHEAD TO BELOW GRADE
EXISTING UTILITY COMPANY UNDERGROUND
PRIMARY FEED TO PADMOUNT TRANSFORMER.
(NOTE: PRIMARY FEED REPLACED WITH NEW ~ 2017
[AROUND 7 YEARS OLD])
EXISTING UNDERGROUND FEED FROM
PADMOUNT TRANSFORMER TO EXISTING
MAIN DISTRIBUTION SWITCHBOARD.
NOTE 2.
EXISTING MAIN DISTRIBUTION
SWITCHBOARD
EXISTING UTILITY COMPANY
PADMOUNT TRANSFORMER,
500KVA, 480Y/277V, 3PH 4W.
Z=1.9% ("LIVE" FRONT PRIMARY)
NEW MAIN DISTRIBUTION SWITCHBOARD
NEW UNDERGROUND FEED FROM
PADMOUNT TRANSFORMER TO NEW
MAIN DISTRIBUTION SWITCHBOARD
TEMPORARY LOCATION OF
EXISTING AIR COMPRESSOR
NOTE: PER MTG WITH UTILITY COMPANY ON 3/12/2024,
NEED A 2-DAY (WEEKEND) POWER OUTAGE TO DISCONNECT PRIMARY FEEDER,
SET NEW PADMOUNT TRANSFORMER, REWORK PRIMARY FEEDER TO NEW
TRANSFORMER AND MAKE ALL PRIMARY AND SECONDARY CONNECTIONS.
NOTE: DURING THE 2-DAY (WEEKEND) POWER
OUTAGE (FOR UTILITY CO. WORK) ELEC
CONTRACTOR SHALL DISCONNECT THE UTILITY
FEED TO THE EXISTING MAIN SWITCHGEAR AND
PROVIDE NEW TEMPORARY FEED TO EXISTING
MAIN SWITCHGEAR FROM THE NEW MAIN
DISTRIBUTION SWITCHGEAR.
NOTE 3.
1. PROVIDE TRIAD GROUNDING ELECTRODE SYSTEM. SEE GROUNDING
SYSTEM DETAILS, SHEET E1.0, FOR ADDITIONAL REQUIREMENTS. COORDINATE
THE INSTALLATION LOCATION IN FIELD WITH ALL EXISTING UNDERGROUND
UTILITIES AND INSTALLATION.
2. THE EXISTING UNDERGROUND UTILITY FEED SHALL HAVE ALL
CONDUCTORS REMOVED. EXTERIOR CONDUIT ENDS SHALL BE CAPPED. THE
INTERIOR CONDUIT ENDS SHALL BE CUT FLUSH WITH FLOOR AND FILLED.
3. PRIOR TO BACK-FEEDING THE EXISTING MAIN DISTRIBUTION
SWITCHBOARD, THE CONTRACTOR SHALL DISCONNECT THE NEUTRAL /
GROUND BOND SO THAT THE ONLY PLACE WHERE THE NEUTRAL / GROUND
BOND OCCURS IS WITHIN THE NEW MAIN DISTRIBUTION SWITCHBOARD (I.E.
SERVICE DISCONNECT LOCATION). NOTE: THE NEW GROUNDING ELECTRODE
SYSTEM AND ALL REQUIRED GROUNDING/BONDING SHALL BE IN-PLACE PRIOR
TO BACK-FEEDING THE EXISTING DISTRIBUTION EQUIPMENT.
4. PROVIDE ALL SAW-CUTTING, REMOVALS, EXCAVATION, BACK-FILLING,
PATCHING AND REPAIR OF SITE AREAS & AREAS WITHIN THE BUILDING
REQUIRED TO PROVIDE NEW INSTALLATION.
5. PROVIDE ALL SAW-CUTTING, REMOVALS, EXCAVATION, BACK-FILLING,
PATCHING AND REPAIR OF SITE AREAS (CONCRETE, ASPHALT & PLANTED
AREAS) REQUIRED TO PROVIDE NEW INSTALLATION & LEAVE AS WAS (I.E.
ASPHALTED AREAS SHALL BE ASPHALTED, CONCRETE AREAS SHALL BE
CONCRETE, PLANTED AREAS SHALL BE PLANTED, ETC.) PRIOR TO START OF
DEMOLITION.
NOTES:
NOTE 1
NEW EMERGENCY POWER GENERATOR ON CONCRETE BASE
FINAL LOCATION OF EXISTING AIR
COMPRESSOR (OLD EMERGENCY
GENERATOR LOCATION)
NEW ELEC RM "1E"
NEW ELEC RM "14E"
NEW ELEC RM "19E" NEW ELEC RM "24E"
PROVIDE PROTECTION BOLLARD.
TYPICAL, OF 13. SEE CONCRETE FILLED
PROTECTION BOLLARD DETAIL, THIS
SHEET FOR ADDITIONAL REQUIREMENTS.
NOTE 4
NOTES 4 & 5
NOTE 5
SECTION VIEW
PLAN VIEW
GROUNDING ELECTRODE SYSTEM DETAIL
NO SCALE
20'-0"
60°
20'-0"
FINISHED GRADE
3'-0"
#4/0 INSULATED COPPER
GROUND CABLE TO BUILDING
MAIN GROUND BUS BAR,
LOCATED WITHIN THE MAIN
ELECTRICAL ROOM. ROUTE
CABLE WITHIN CONDUIT
WHERE CABLE IS ROUTED
THROUGH CONCRETE OR
MASONRY WALLS AND
FLOORS. SEE GROUNDING
SYSTEM RISER DIAGRAM,
SHEET E1.0, FOR ADDITIONAL
REQUIREMENTS.
3/4" x 10'-0" COPPER
GROUND ROD. TYPICAL.
EXOTHERMIC WELD OR
IRREVERSIBLE COMPRESSION
TYPE BOND. TYPICAL.
#4/0 INSULATED COPPER
GROUND ROD BONDING CABLES.
GROUNDING SYSTEM RISER DIAGRAM
NO SCALE
GENERAL GROUNDING NOTE:
ALL BONDS TO GROUND BUS BARS SHALL BE MADE USING 2-HOLE TYPE MECHANICAL LUGS.
BOND TRANSFORMER(S) SECONDARY
NEUTRAL "X0" TO GROUND BUS BAR.
SEE ONE-LINE DIAGRAM, SHEET E3.2,
FOR ADDITIONAL REQUIREMENTS
TRIAD BUILDING GROUNDING
ELECTRODE SYSTEM. SEE
GROUNDING ELECTRODE SYSTEM
DETAIL, THIS SHEET, FOR
ADDITIONAL REQUIREMENTS.
BUILDING MAIN GROUND BUS BAR.
PROVIDE 1/4"(T) x 4"(H) x 18"(L) COPPER BUS
BAR ON INSULATED STAND-OFF DEVICES.
[PROVIDE WITHIN THE MAIN ELEC ROOM]
1#4/0 INSULATED COPPER
CABLE IN CONDUIT RACEWAY.
BOND TO NEUTRAL BUS WITHIN THE MAIN
DISTRIBUTION SWITCHBOARD USING #4/0
INSULATED COPPER CABLE INSTALLED
WITHIN NON-FERROUS (AL) CONDUIT.
BOND TO NEAREST BUILDING
STRUCTURAL STEEL COLUMN USING #4/0
INSULATED COPPER CABLE INSTALLED
WITHIN NON-FERROUS (AL) CONDUIT.
BOND BUILDING METALLIC PIPING
SYSTEMS TO THE BUS BAR USING #3/0
INSULATED COPPER CABLE INSTALLED
WITHIN NON-FERROUS (AL) CONDUIT.
1#4/0 INSULATED
COPPER CABLE IN
CONDUIT RACEWAY.
GROUND BUS BAR. PROVIDE 1/4"(T) x 4"(H) x 12"(L)
COPPER BUS BAR ON INSULATED STAND-OFF
DEVICES. [PROVIDE WITHIN NEW ELEC ROOM 24E].
GROUND BUS BAR. PROVIDE 1/4"(T) x 4"(H) x 12"(L)
COPPER BUS BAR ON INSULATED STAND-OFF
DEVICES. [PROVIDE WITHIN NEW ELEC ROOM 19E].
GROUND BUS BAR. PROVIDE 1/4"(T) x 4"(H) x 12"(L)
COPPER BUS BAR ON INSULATED STAND-OFF
DEVICES. [PROVIDE WITHIN NEW ELEC ROOM 14E].
GROUND BUS BAR. PROVIDE 1/4"(T) x 4"(H) x 12"(L) COPPER BUS BAR ON
INSULATED STAND-OFF DEVICES. [PROVIDE WITHIN NEW ELEC ROOM 1E].
BOND TRANSFORMER(S) SECONDARY NEUTRAL "X0" TO
GROUND BUS BAR. SEE ONE-LINE DIAGRAM, SHEET E3.2,
FOR ADDITIONAL REQUIREMENTS
BOND TRANSFORMER(S) SECONDARY NEUTRAL "X0" TO GROUND BUS BAR.
SEE ONE-LINE DIAGRAM, SHEET E3.2, FOR ADDITIONAL REQUIREMENTS.
BOND TRANSFORMER(S) SECONDARY NEUTRAL "X0" TO GROUND BUS BAR.
SEE ONE-LINE DIAGRAM, SHEET E3.2, FOR ADDITIONAL REQUIREMENTS.
#4/0 INSULATED COPPER
GROUND CABLE TO EMERGENCY
POWER GENERATOR "X0". ROUTE
CABLE WITHIN CONDUIT WHERE
CABLE IS ROUTED BELOW
AND/OR THROUGH CONCRETE .
LIGHTING FIXTURE SCHEDULE
MANUFACTURERSYMBOL DESCRIPTION
TYPE
FIXTURE SERIES
LAMP
LENSWATTS REFLECTOR
MOUNTING
LIGHT CONTROL
REMARKS
FIXTURE
VOLTAGEQNTY PER
FIXTURE
LITHONIA
120/277
(MULTI-
VOLT)
COOPER LTG
METALUX
QNTY AS
REQUIRED
45W
(NOMINAL
FIXTURE
INPUT
WATTS)
RECESSED,
T-GRID ---
2'x4' LED EDGE-LIT FLAT PANEL, FULLY LUMINOUS
APPEARANCE ACROSS FACE OF THE LENS. PROVIDE
FIXTURE WITH DIMMING CAPABILITIES DOWN TO 1% OF FULL
RATED LUMEN OUTPUT.
(2.2" MAX FIXTURE DEPTH).
[FIXTURE LUMEN OUTPUT ~ 4998 LUMENS]
SATIN
WHITE
LEDS 3500K
(60,000 HRS WITH
97% LUMEN
MAINTENANCE)
L97/60
80+ CRI
EPANL-2x4-4800LM-80CRI-35K-1% DIMMING (0-to-10V)-MVOLT SERIES
24FP4735C-80CRI-35K-1% DIMMING
(0-to-10V)-UNV SERIES
F1D
F2
LITHONIA
120/277
(MULTI-
VOLT)
QNTY AS
REQUIRED
34W
(NOMINAL
FIXTURE
INPUT
WATTS)
SUSPENDED,
AIRCRAFT
CABLE
4' LENGTH LED STRIP LIGHTING FIXTURE WITH WHITE FINISH
AND SNAP-ON FLAT LENS.
[FIXTURE DIMENSIONS: 2-1/8"(H) x 2-3/16"(W) x 48"(L)].
[FIXTURE LUMEN OUTPUT ~ 4585 LUMENS]
SNAP-ON / OFF
FROSTED ,
DIFFUSE,
SYMMETRICAL
DISTRIBUTION
LEDS 4000K
(60,000 HRS WITH
70% LUMEN
MAINTENANCE)
L70/60
80 CRI
ZL1N-L48-SMR-5000LM-FST-
MVOLT-40K-80CRI-WH SERIES
1. COORDINATE THE REQUIRED INSTALLATION HEIGHT
(SUSPENSION ABOVE FINISHED FLOOR) WITH THE ARCHITECT
PRIOR TO START OF ROUGH-IN. PROVIDE ALL REQUIRED
SUPPLEMENTAL STEEL INSTALLATION AS REQUIRED TO INSTALL
FIXTURES IN THE GENERAL LOCATIONS AS INDICATED ON THE
CONTRACT DRAWINGS.
(END OF LIGHTING FIXTURE SCHEDULE)
COOPER LTG
METALUX
F3D
LITHONIA
120/277
(MULTI-
VOLT)
QNTY AS
REQUIRED
31W
(NOMINAL
FIXTURE
INPUT
WATTS)
SUSPENDED,
AIRCRAFT
CABLE
2' LENGTH LED STRIP LIGHTING FIXTURE WITH WHITE FINISH
AND SNAP-ON FLAT LENS. FIXTURE SHALL BE DIMMABLE
DOWN TO 1% OF FULL LUMEN OUTPUT.
[FIXTURE DIMENSIONS: 2-1/8"(H) x 2-3/16"(W) x 24"(L)].
[FIXTURE LUMEN OUTPUT ~ 3666 LUMENS]
SNAP-ON / OFF
FROSTED ,
DIFFUSE,
SYMMETRICAL
DISTRIBUTION
LEDS 3500K
(60,000 HRS WITH
70% LUMEN
MAINTENANCE)
L70/60
80 CRI
ZL1N-L24-SMR-3500LM-FST-1% DIMMING
(0-to-10V)-MVOLT-35K-80CRI-WH SERIES
1. COORDINATE THE REQUIRED INSTALLATION HEIGHT
(SUSPENSION ABOVE FINISHED FLOOR) WITH THE ARCHITECT
PRIOR TO START OF ROUGH-IN. PROVIDE ALL REQUIRED
SUPPLEMENTAL STEEL INSTALLATION AS REQUIRED TO INSTALL
FIXTURES IN THE GENERAL LOCATIONS AS INDICATED ON THE
CONTRACT DRAWINGS.
COOPER LTG
METALUX
F4
EMB2
LED THERMOPLASTIC EMERGENCY LIGHTING UNIT WITH
TWO LED FIXTURE HEADS, INTEGRAL BATTERY BACK-UP
WITH HIGH OUTPUT WITH LITHIUM ION PHOSPHATE
BATTERIES CAPABLE OF 120 MINUTES OF OPERATION ON
LOSS OF NORMAL POWER SOURCE. PROVIDE WITH SELF-
DIAGNOSTICS.
ISOLITE BUG-6-WH-SD SERIES
120/277
(MULTI-
VOLT)
QNTY TWO
FIXTURE
HEADS
(QNTY 3 -
2W LEDS
PER HEAD)
6W PER
LAMP
HEAD
(12W
TOTAL)
SURFACE
WALLLED ---
1. COORDINATE THE REQUIRED INSTALLATION LOCATIONS AND
MOUNTING HEIGHT IN FIELD WITH ALL OTHER INSTALLATION
WITHIN THE INSTALLED ROOMS. AIM FIXTURE HEADS TO PROVIDE
THE MAXIMUM ILLUMINATION ON PATHWAYS AND EQUIPMENT
WHICH REQUIRES INSPECTION AND MAINTENANCE DURING A LOSS
OF NORMAL POWER CONDITION.
LITHONIA
120/277
(MULTI-
VOLT)
QNTY AS
REQUIRED
104W
(NOMINAL
FIXTURE
INPUT
WATTS)
SUSPENDED,
AIRCRAFT
CABLE
8' LENGTH LED STRIP LIGHTING FIXTURE WITH SYMMETRIC
REFLECTORS, WHITE FINISH AND SNAP-ON FLAT LENS.
[FIXTURE DIMENSIONS: 2-1/8"(H) x 2-3/16"(W) x 96"(L)].
[FIXTURE LUMEN OUTPUT ~ 12,933 LUMENS]
SNAP-ON / OFF
FROSTED ,
DIFFUSE,
SYMMETRICAL
DISTRIBUTION
LEDS 4000K
(60,000 HRS WITH
70% LUMEN
MAINTENANCE)
L70/60
80 CRI
TZL1N-L96-SMR-14000LM-FST-
MVOLT-40K-80CRI-WH SERIES
SYMMETRIC,
WHITE
FINISH
1. COORDINATE THE REQUIRED INSTALLATION HEIGHT
(SUSPENSION ABOVE FINISHED FLOOR) WITH THE ARCHITECT
PRIOR TO START OF ROUGH-IN. PROVIDE ALL REQUIRED
SUPPLEMENTAL STEEL INSTALLATION AS REQUIRED TO INSTALL
FIXTURES IN THE GENERAL LOCATIONS AS INDICATED ON THE
CONTRACT DRAWINGS.
COOPER LTG
METALUX
1. PROVIDE WITH QUANTITY OF DIMMER CONTROL SWITCHES AS
INDICATED ON THE CONTRACT DRAWINGS. DIMMER SWITCHES
SHALL BE FULLY COMPATIBLE WITH THE INSTALLED LIGHTING
FIXTURES.
COLUMBIA LTG
CBT24-A-LSCS-EDD-80CRI-35K-1%
DIMMING (0-to-10V) SERIES
ORACLE LTG
4-OC4-LED-5000L-1% DIMMING (0-
to-10V)-MVOLT-40K-85-WHITE SERIES
ORACLE LTG
2-OC4-LED-4000L-1% DIMMING (0-
to-10V)-MVOLT-35K-85-WHITE SERIES1
ORACLE LTG
8-OC4-LED-14000L-1% DIMMING (0-
to-10V)-MVOLT-40K-85-WHITE SERIES
DUAL-LITE EVHC12I-06L (WITH 120 MINUTE
BATTERY BACKUP) WHITE SERIES
4SNLED-LD5-48SL-SLW-UNV-L840-
CD1-U-WHITE SERIES
2SNLED-LD5-30HL-SLW-UNV-L835-CD1-U-
1% DIMMING (0-to-10V)-WHITE SERIES
8TSNLED-LD5-170HL-SLW-UNV-L840-
CD1-U-WHITE SERIES
EVEN-LITE TEBL6W-SD (WITH 120 MINUTE
BATTERY BACKUP) WHITE SERIES
DETAIL - GENSET CONCRETE BASE
NO SCALE
12" 12"
10"
28"
TOP OF PAD SHALL BE
SET AT AN ELEVATION
OF 4" ABOVE ADJACENT
FINISHED GRADE. SLOPE
FINISHED GRADE.1" CHAMFERED EDGE
NOTE: COORDINATE REQUIRED DIMENSIONS WITH GENERATOR SET TO ALLOW
PAD TO EXTEND 12" PAST THE OUTERMOST DIMENSIONS OF THE GENERATOR
AND BASE ON SIDES OF THE GENERATOR SET / ENCLOSURE WHICH DO NOT
REQUIRE ACCESS FOR MAINTENANCE. ON SIDES WHICH DO REQUIRE ACCESS FOR
MAINTENANCE AND INSPECTION, THE BASE SHALL EXTEND A MINIMUM OF 42" PAST
THE OUTER MOST EDGE OF THE GENERATOR SET / ENCLOSURE.
NOTE: IF A PLATFORM(S) ARE REQUIRED TO ACCESS OVERCURRENT PROTECTION
DEVICES, THEN THE BASE SHALL EXTEND A MINIMUM OF 6" PAST THE EDGE OF
THE PLATFORM.
#4's CONT. @ 12" O.C.
EA. WAY
PAD TO DRAIN
#4's @ 12" O.C.
EA. WAY
8" COMPACTED GRANULAR
FILL ON SUITABLE SUBGRADE
CAST IN-PLACE CONCRETE PAD.
4000 PSI W/ 6% ENTRAINED AIR.
PROVIDE LIGHT BROOM FINISH.
3 WIDE BY 3 DEEP DUCTBANK DETAIL
NO SCALE
MASONRY LEVELING
BLOCKS AT BASE
SPACERS AS NEEDED
BASE AND INTERMEDIATE
SPACERS 48" ON CENTER
SCHED 40 PVC CONDUIT
RACEWAY (TYPICAL)
4000 PSI
CONCRETE
#4 REBAR. TYPICAL.
#4 REBAR. TYPICAL.
18" ON CENTER
3" MINIMUM SEPARATION.
TYPICAL.
3" MINIMUM.
TYPICAL.
3" MINIMUM
SEPARATION.
TYPICAL.
1-1/2" MINIMUM
SEPARATION.
TYPICAL.
FINISHED GRADE
DUCTBANK
MARKING TAPE.
TYPICAL.EQUAL
EQUAL
M
IN
IM
U
M
#4 REBAR. TYPICAL.
1' - 6"
6" DIA. GALV. STANDARD
STEEL POST, FILL W/
CONCRETE (PAINT BRIGHT YELLOW)
SEALANT OVER 1/2"
EXPANSION JOINT IN
ASPHALT PAVEMENT
FIBER REINFORCED
CONCRETE FOUNDATION
COAT STEEL W/ BITUMINOUS
PAINT BELOW GRADE
COMPACTED #53 STONE BASE
COMPACTED SUBGRADE OR
BACKFILL, 96% MAX. DENSITY
CROWN CONCRETE FILL
REFLECTIVE BOLLARD TAPE
(2 BANDS) - TYPE 1, BY
REFLECTIVE INC.
CONCRETE WASH
NO SCALE
DETAIL - CONCRETE FILLED
PROTECTION BOLLARD
S
S3a a
"WP"
PHASE
CONDUCTOR
NEUTRAL
GROUND
HOMERUN TO PANEL INDICATED. PREFIX INDICATES PANEL
NOMENCLATURE. NUMBERS INDICATE CIRCUIT NUMBERS.
C1-1
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
WALL OUTLET WITH 20A, 125V DUPLEX RECEPTACLE.
MOUNT 18 INCHES ABOVE FINISHED FLOOR TO
CENTER, UNLESS NOTED OTHERWISE.
WALL OUTLET WITH 20A, 125V DOUBLE-DUPLEX RECEPTACLE.
MOUNT 18 INCHES ABOVE FINISHED FLOOR TO CENTER,
UNLESS NOTED OTHERWISE.
SYMBOL INDICATES FIXTURE TYPE WHEN SHOWN ON
LIGHTING PLANS ADJACENT TO FIXTURE SYMBOL. REFER
TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE
REQUIREMENTS.
CIRCUIT. NUMBER OF CROSSBARS INDICATE QUANTITY OF
CONDUCTORS REQUIRED. MINIMUM CONDUIT SIZE SHALL BE 3/4
INCH TRADE SIZE. MINIMUM SIZE CONDUCTORS SHALL BE 12 AWG.
"GFI"
VOICE/DATA OUTLET. MOUNT OUTLET AT SAME HEIGHT AS
ASSOCIATED POWER OUTLET, UNLESS NOTED OTHERWISE.
PROVIDE 1 INCH CONDUIT FROM OUTLET BOX TO NEAREST
ACCESSIBLE CEILING CAVITY. BUSH CONDUIT ENDS. OUTLET
BOX SHALL BE 4" SQUARE BY 2-3/4" DEEP WITH A SINGLE-GANG
PLASTER RING, UNLESS NOTED OTHERWISE.
"C1" - INDICATES PROVIDE ONE DATA CABLE TO OUTLET BOX.
"C2" - INDICATES PROVIDE TWO DATA CABLES TO OUTLET BOX.
"C3" - INDICATES PROVIDE THREE DATA CABLES TO OUTLET BOX.
"C4" - INDICATES PROVIDE FOUR DATA CABLES TO OUTLET BOX.
"B" - INDICATES THE OUTLET LOCATION SHALL BE PROVIDED
WITH A PULL STRING AND A BLANK DEVICE PLATE.
DESCRIPTIONSYMBOL
OUTLET BOX AND 20A, THREE-WAY SWITCH. MOUNT AT 46
INCHES ABOVE FINISHED FLOOR TO CENTER, UNLESS
NOTED OTHERWISE. LOCATE WITHIN 8" OF STRIKE SIDE
OF DOOR, UNLESS NOTED OTHERWISE.
OUTLET BOX AND 20A, SINGLE POLE SWITCH. MOUNT AT
46 INCHES ABOVE FINISHED FLOOR TO CENTER, UNLESS
NOTED OTHERWISE. LOCATE WITHIN 8" OF STRIKE SIDE
OF DOOR, UNLESS NOTED OTHERWISE. LOWER CASE
LETTER INDICATES CIRCUIT SWITCHED.
NOMENCLATURE INDICATES GROUND FAULT INTERRUPTER
TYPE RECEPTACLE WHEN SHOWN PLANS ADJACENT TO
SYMBOL.
OCCUPANCY SENSOR. THE LETTER(S) DESIGNATION NEXT TO
THE SYMBOL (IF SHOWN) INDICATE SWITCHING ZONES TO BE
CONTROLLED VIA THE OCCUPANCY SENSOR. IF A LETTER
DESIGNATION IS NOT SHOWN, THE OCCUPANCY SENSOR SHALL
CONTROL ALL LIGHTING FIXTURES WITHIN THE ROOM.
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
a
ELECTRICAL LEGEND
CEILING OUTLET AND LIGHTING FIXTURE AS SCHEDULED.
NOMENCLATURE INDICATES GFI TYPE, OUTDOOR RATED
WEATHER RESISTANT TYPE RECEPTACLE IN CAST ALUMINUM
LOCKABLE TYPE WEATHER-PROOF-WHILE IN-USE ENCLOSURE
WHEN SHOWN ON PLANS ADJACENT TO SYMBOL. O
a
OUTLET BOX AND DIMMER SWITCH RATED FOR
CONNECTED LOAD. MOUNT AT 46 INCHES ABOVE
FINISHED FLOOR TO CENTER, UNLESS NOTED
OTHERWISE. LOCATE WITHIN 8" OF STRIKE SIDE OF
DOOR, UNLESS NOTED OTHERWISE. LOWER CASE
LETTER INDICATES CIRCUIT CONTROLLED.
F1
DESCRIPTIONSYMBOL
OUTLET BOX AND DIMMER SWITCH (WITH INTEGRAL
OCCUPANCY SENSOR) RATED FOR CONNECTED LOAD.
MOUNT AT 46 INCHES ABOVE FINISHED FLOOR TO
CENTER, UNLESS NOTED OTHERWISE. LOCATE WITHIN 8"
OF STRIKE SIDE OF DOOR, UNLESS NOTED OTHERWISE.
LOWER CASE LETTER INDICATES CIRCUIT CONTROLLED.
CEILING MOUNT SMOKE DETECTOR.
AUDIO-VISUAL ALARM DEVICE. FIRE ALARM SYSTEM.
WALL MOUNT AT 80 INCHES A.F.F. TO CENTER, OR 6
INCHES BELOW CEILING TO TOP, WHICHEVER IS LOWER.
F S
F
R E
NI
G
NEAN L
OI
S
E
S
F O R P
E
KENTU
C
K Y
FO
ET
A T S
D
ESNE
L I C
BROCKMAN
18703
J.
A T T
M
HE
W
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS-BUILT DATE
DECA LOG #
DESCRIPTION OF REVISIONS DATE
DESCRIPTION OF REVISIONS DATE
DRAWING INFORMATION
A & E FILE NO.
DRAWN BY
CHECKED BY
PHASE
RTA DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
ACCOUNT NO.
DRAWING DATE
470-CB72-OC33-00
6/28/2024
06/28/2024
/1
/2
:3 :5
P
M
KCTCS - SWITCHGEAR REPLACEMENT - OWENSBORO COMMUNITY &
TECHNICAL COLLEGE - DOWNTOWN CAMPUS
MJB
6/28/2024
MJB
SITE ELECTRICAL PLAN
E1.0
2401-116
"C" - RTA
1" = 30'-0"
SITE ELECTRICAL PLAN
5'0' 15' 30'
1''=30'-0''
True North
Plan North
Approximate
NOTE: THIS PAD DETAIL WAS FURNISHED TO HAFER BY OMU AND IS INCLUDED ON THIS DRAWING FOR CONTRACTOR'S USE IN THE BIDDING PROCESS. ALL INSTALLATION SHALL BE IN ACCORDANCE WITH OMU. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIREMENTS WITH OMU PRIOR TO START OF DEMOLITION AND NEW CONSTRUCTION.
ADDENDUM NO. 1 7/22/2024
ADDENDUM NO. 3 8/15/2024
S
S
F S
S
F S
S
F S
F
S
F S
F
S S
SS
F S
F S
NOTE 2.
(OLD PANEL "D" LOCATION)
NOTE 2.
(OLD PANEL "A" LOCATION)
EXISTING PANEL "R"
OLD LOCATION OF REMOVED
MAIN SWITCHBOARD "MSB"
PANEL "M1"
EXISTING PANEL "K1"
OFFICE
7B OFFICE
7A
SMALL
CLASSROOM
7C
CLASSROOM
CLASSROOM
STORAGE
5A
STORAGE
3A
CLASSROOM
3B
CLASSROOM
OFFICE
1D
OFFICE
1A
OFFICE
1B
OFFICE
1C
SKILL
TRAIN
OFFICE
WEST
VESTIBULE
123A
OFFICE
S2
GENERAL
OFFICE
S1
BREAKROOM
OFFICE
S3
OFFICE
S4
OFFICE
S5
OFFICE
S6
NORTH
VESTIBULE
160A
OFFICE
S8
VAULT
S7
LOBBY
WEST
CORRIDOR
MEN
WOMEN
EMPLOYEE
LOUNGE
F1
TOILET
125A
COMM.
TESTING
LAB
TOOLS
6A
STORAGE
6B
OFFICE
2A
COMPUTER
TESTING
COMM.
8A
OFFICE
8B
TOWER
OFFICE
14A
STORAGE
14C
CONTROL
14B
WAITING
STUDIO
14D
OFFICE
14E
CLASSROOM
14F
OFFICE
14H
RADIO
ROOM
14G
M&O
BREAKROOM/STORAGE
13A
WEST
MEN
WEST
CUSTODIAL
WEST
WOMEN
MECHANICAL
13B
PASSAGE
STORAGE
15C
STORAGE
15B
STORAGE
15D
INDUSTRY
INNOVATION
LAB
COMPUTER
LAB /
CLASSROOM
15A
OFFICE
17B
INDUSTRY
INNOVATION
LAB
TOOLS &
STORAGE
17A
NORTH
CORRIDOR
CARPENTRY
SHOP
TOOLS &
STORAGE
19A
OFFICE /
RESOURCE
19B
OFFICE /
RESOURCE
21B
MASONRY
SHOP
STORAGE
21A
OFFICE /
RESOURCE
18C
STORAGE
18D
STORAGE
18E
CLASSROOM
20C
CLASSROOM
20A
OFFICE
20B
OFFICE/STOR
22A SECRETARY
STORAGE
24D
OFFICE
22B
CLO.
106J
STORAGE
24C
HEALTH
OCCUPATIONS
SHOP
FLAMMABLE
LIQUID
STORAGE
STORAGE
MAIN
ELEC
WOMENS
DRESSING
EAST
WOMEN
EAST
MEN
MENS
DRESSING
EAST
CUSTODIAL
150 ART LAB
TOOLS &
STORAGE
25A
OFFICE
25B
CLASSROOM
CLASSROOM
LECTURE
ROOMS 1
& 2
24A
SURGERY
23G
STERILE
PREP
23F
FELINE
WARD
23E
LAB
ANIMAL
23D
CLOS.
23C
EXAM
ROOM
23A
WAITING
BUSINESS
OFFICE
STORAGE
23R
PHARMACY
23Q
CANINE
WARD
23L
UTILITY
ROOM
23N
SURGERY
PREP
23H
IMAGING
23J
CLINICAL
CARE
23S
CORR.
23B
LABORATORY
23P
DENTAL
SUITE
23O
ENTRY
23K
EAST
CORRIDOR
14K
NORTH
CORRIDOR
14L
TRAINING
/ CONF
SPACE
BREAKROOM
12 FIRE
PROTECTION
14I
CLASSROOM
18B
CLASSROOM
18A
CLASSROOM
OFFICES
Room
C1
Room
EXISTING PANEL "K LEFT"
EXISTING PANEL "K RIGHT"
TRANSFORMER "XK"
EXISTING
DISCONNECT
(BOILER)
EXISTING COMBO
STARTER
(OFFICE H.W. PUMP 3)
EXISTING COMBO
STARTER
(H.W. PUMP 4)
EXISTING COMBO STARTER
EXISTING COMBO
STARTER
(AIR COMP.)
DISTRIBUTION PANEL "H".
NOTES 16 & 17.
EXISTING DISC. SW "D100"
EXISTING DISC. SW "D101"
EXISTING
DISCONNECT D102
(GRINDER)
EXISTING
DISCONNECT D103
(DRILL PRESS)
EXISTING PANEL "N1A".
NOTE 9.
EXISTING DISC SW "E"
EXISTING DISC SW "D"
EXISTING DISC SW "C"
EXISTING DISC SW "B"
EXISTING DISC SW "A"
EXISTING PANEL "17"
ENCLOSED CIRCUIT
BREAKER "CBXN1"
DISTRIBUTION
PANEL "N"
EXISTING TRANSFORMER "XN1".
NOTE 34.
NOTES 7 & 28.
(OLD PANEL
"G1" LOCATION)
EXISTING DISC SWITCH
"DS-XRAY" DISTRIBUTION
PANEL "M"
EXISTING PANEL "MM".
NOTE 9.
NOTES 8 & 28.
(OLD PANEL "J1"
LOCATION)
EXISTING TELCOM
SERVICE ENCLOSURE
RELOCATED AIR
COMPRESSOR
(TEMPORARY LOCATION)
PANEL "P21"
PANEL "P22"
EXISTING
DISCONNECT D104
1. COORDINATE THE NEW PANEL INSTALLATION LOCATION WITH THE ASSOCIATED PANEL LOCATION TO BE DEMOLISHED AS REQUIRED TO ALLOW USE OF THE DEMOLISHED PANEL LOCATION BACKBOX TO BE USED AS A
JUNCTION BOX.
2. REWORK AND MODIFY THE DEMOLISHED PANEL BACKBOX AS REQUIRED SO THAT IT CAN BE USED AS A JUNCTION BOX TO REFEED THE EXISTING BRANCH CIRCUITS (REQUIRED TO REMAIN OPERATIONAL) FROM THE NEW PANEL. DISCONNECT AND REMOVE THE PANEL GUTS. CUT BACKBOX ENCLOSURE SUCH THAT THE BACKBOX IS FLUSH WITH THE CORRIDOR FINISHED WALL. REMOVE TRIM IN CORRIDOR INSTALLED AROUND THE PERIMETER OF THE BACK BOX. PROVIDE NEW COVER OVER BACKBOX WHICH COVERS THE BACKBOX AND EXTENDS A
MINIMUM OF 2" PAST ALL EDGES OF THE BACKBOX.
3. COPPER GROUND BUS BAR ON INSULATED STAND-OFF DEVICES. SEE GROUNDING SYSTEM DETAILS AND
GROUNDING SYSTEM RISER DIAGRAM, SHEET E1.0, FOR ADDITIONAL REQUIREMENTS.
4. SAW CUT, REMOVE, REWORK WALL AS REQUIRED TO REMOVE OLD PANEL BACKBOX AND PROVIDE NEW RECESSED (FLUSH WITH CORRIDOR WALL FINISH) JUNCTION BOX. EXTEND, REWORK EXISTING BRANCH CIRCUIT CONDUITS (AND CIRCUITS) AS REQUIRED TO CONNECT TO NEW JUNCTION BOX. PROVIDE NEW BRANCH CIRCUIT CONDUITS & CIRCUITS FROM NEW PANEL WITHIN NEW ELECTRICAL AS REQUIRED TO REFEED EXISTING LOADS.
PATCH AND PAINT WALL TO MATCH EXISTING FINISHES. PROVIDE COVER OVER JUNCTION BOX WHICH COVERS
JUNCTION BOX.
5. USE THE POWER QUALITY / ENERGY METERING EQUIPMENT, JUNCTION BOX WITH FUSE KIT FOR PROTECTION OF THE METERING EQUIPMENT, AND ALL ASSOCIATED CIRCUITS AND ROPE TYPE CTs REMOVED FOR RELOCATION. THE METERING EQUIPMENT AND TIE-IN WITH THE BUILDING MANAGEMENT SYSTEM & ENERGY MONITORING SYSTEM SHALL BE REWORKED AS REQUIRED AND CONNECTED TO THE NEW MAIN DISTRIBUTION SYSTEM. OPERATION OF THE REMOVED METERING/ENERGY MONITORING SYSTEM WHEN REINSTALLED ON THE NEW MAIN DISTRIBUTION SWITCHBOARD SHALL BE AS WAS PRIOR TO START OF DEMOLITION. PROVIDE A 15A, 480V 3PH BRANCH CIRCUIT TO METERING EQUIPMENT FROM A CIRCUIT BREAKER PROVIDED WITHIN THE MAIN DISTRIBUTION SWITCHBOARD. COORDINATE INSTALLATION LOCATION AND MOUNTING HEIGHT SUCH THAT THE SIDE COVERS OF THE NEW MAIN DISTRIBUTION SWITCHBOARD CAN BE REMOVED FOR FUTURE MAINTENANCE /
ACCESS.
6. PROVIDE BUILDING MAIN COPPER GROUND BUS BAR ON INSULATED STAND-OFF DEVICES. SEE GROUNDING SYSTEM DETAILS AND GROUNDING SYSTEM RISER DIAGRAM, SHEET E1.0, FOR ADDITIONAL REQUIREMENTS.
7. PROVIDE NEW PULL / JUNCTION BOXES IN CEILING CAVITY SPACE ABOVE THE OLD PANEL "G1" LOCATION AS REQUIRED TO REFED THE EXISTING LOADS FROM THE NEW PANEL "G1". THE OLD PANEL "G1" SHALL BE DISCONNECTED AND REMOVED COMPLETE. THE BACKBOX SHALL NOT BE REUSED AS A JUNCTION BOX OR PULL
BOX.
8. PROVIDE NEW PULL / JUNCTION BOXES IN CEILING CAVITY SPACE ABOVE THE OLD PANEL "J1" LOCATION AS REQUIRED TO REFED THE EXISTING LOADS FROM THE NEW PANEL "J1". THE OLD PANEL "J1" SHALL BE DISCONNECTED AND REMOVED COMPLETE. THE BACKBOX SHALL NOT BE REUSED AS A JUNCTION BOX OR PULL
BOX.
9. SEE ONE-LINE DIAGRAM, SHEET E3.2, FOR ADDITIONAL REQUIREMENTS REGARDING THE NEW FEED TO THE
EXISTING PANEL.
10. PROVIDE NEW PULL / JUNCTION BOXES IN CEILING CAVITY SPACE ABOVE THE OLD PANEL "F1" LOCATION AS REQUIRED TO REFED THE EXISTING LOADS FROM THE NEW PANEL "F". THE OLD PANEL "F1" SHALL BE DISCONNECTED AND REMOVED COMPLETE. THE BACKBOX SHALL NOT BE REUSED AS A JUNCTION BOX OR PULL
BOX.
11. SEE ONE-LINE DIAGRAM, SHEET E3.2, FOR ADDITIONAL REQUIREMENTS REGARDING THE NEW FEED AND FUSIBLE SAFETY DISCONNECT SWITCH TO EXISTING KILN EQUIPMENT. COORDINATE THE REQUIRED INSTALLATION LOCATION IN FIELD. PROVIDE FUSING PER THE EQUIPMENT MANUFACTURER'S REQUIREMENTS.
PROVIDE FINAL CIRCUIT FROM DISCONNECT SWITCH TO KILN EQUIPMENT PER NEC AND EQUIPMENT
MANUFACTURER'S REQUIREMENTS.
12. SEE ONE-LINE DIAGRAM, SHEET E3.2, FOR ADDITIONAL REQUIREMENTS REGARDING THE NEW FEED TO THE
EXISTING COMBINATION MOTOR CONTROLLER.
13. REWORK THE CIRCUIT RACEWAYS AS REQUIRED AND PROVIDE NEW CIRCUIT CONDUCTORS AND RACEWAY EXTENSION REQUIRED TO FEED THE EXISTING LOADS ORIGINALLY FED FROM REMOVED PANEL "D1" FROM THE NEW PANEL "B". PROVIDE NEW BRANCH CIRCUIT CONDUCTORS THE ENTIRE LENGTH FROM CIRCUIT BREAKER TO
THE EXISTING LOADS.
14. PROVIDE PULL-BOX (FLUSH MOUNTED WITHIN NEW FURRED-OUT WALL) IN LOCATION AS REQUIRED TO CONNECT TO THE REMOVED PANEL "B" TUB. PROVIDE CONDUIT RACEWAYS FROM NEW PULL-BOX TO EXISTING TUB, AND FROM THE NEW PULL-BOX TO THE NEW PANEL "B" AS REQUIRED TO REFEED THE EXISTING LOADS
ORIGINALLY FED FROM THE REMOVED PANEL "B" FROM THE NEW PANEL "B".
15. USE THE BACK-BOX OF THE REMOVED PANEL "H" AS A SPLICE BOX FOR REFEEDING THE EXISTING LOADS
ORIGINALLY FED FROM PANEL "H". PROVIDE NEW BLANK COVER ON BACKBOX.
16. PROVIDE NEW FEEDER CIRCUIT (CONDUIT AND CONDUCTORS) FROM THE NEW MAIN DISTRIBUTION SWITCHBOARD TO THE NEW PANEL "H". REFEED THE EXISTING LOADS FED FROM THE REMOVED PANEL "H" FROM THE NEW PANEL "H". SEE ONE-LINE DIAGRAM, SHEET E3.2, FOR ADDITIONAL REQUIREMENTS.
17. PROVIDE SUPPORT STRUCTURE AS REQUIRED FOR SUPPORT OF DISTRIBUTION PANEL. SECURE STRUCTURE
TO FLOOR AT THE BOTTOM AND TO THE BUILDING STRUCTURE AT THE TOP.
18. PROVIDE STRUCTURAL STEEL TYPE SUPPORT STRUCTURE AS REQUIRED TO INSTALL TRANSFORMER "XNATS700" ABOVE TRANSFORMER "XNATS702". INSTALL SUCH THAT THE BOTTOM OF TRANSFORMER "XNATS700" IS A MINIMUM OF 24" ABOVE THE TOP OF TRANSFORMER "XNATS702" TO ENSURE ADEQUATE VENTILATION.
SEISMICALLY SECURE THE STRUCTURE TO THE FLOOR AT BOTTOM AND TO THE STRUCTURE WALL & BUILDING
STEEL AT TOP.
19. PROVIDE STRUCTURAL STEEL TYPE SUPPORT STRUCTURE AS REQUIRED TO INSTALL PANELS AND SUPPORT TRANSFORMERS "XEH1(700)" & "XEH1(702)" ABOVE THE ASSOCIATED PANELS FED BY EACH TRANSFORMER.
SEISMICALLY SECURE THE STRUCTURE TO THE FLOOR AT BOTTOM AND TO THE STRUCTURE WALL & BUILDING
STEEL AT TOP.
20. PROVIDE ALL REQUIRED CIRCUITS BETWEEN THE REMOTE ANNUNCIATORS AND THE GENSET AND ATSs AS REQUIRED FOR CORRECT OPERATION. FLUSH MOUNT WITHIN THE WALL. PROVIDE ALL REQUIRED CUTTING, PATCHING, REPAIR AND FINISHING/PAINTING TO MATCH EXISTING WALL FINISHES. COORDINATE THE INSTALLATION LOCATION IN THE FIELD WITH OWNER PRIOR TO START OF DEMOLITION AND ROUGH-IN.
21. PROVIDE SURFACE METAL RACEWAY SYSTEM TO FEED NEW RECEPTACLE(S) SHOWN TO BE INSTALLED ON EXISTING CMU WALLS. RECEPTACLES INSTALLED WITHIN NEW WALLS SHALL BE INSTALLED FLUSH WITHIN NEW
WALL.
22. TEMPORARILY FEED RECEPTACLES IN ROOM FROM A 20A BRANCH CIRCUIT IN EXISTING PANEL "D" WHICH HAS AVAILABLE CAPACITY. PROVIDE THE FINAL FEED TO RECEPTACLES FROM THE NEW PANEL AND CIRCUIT AS
INDICATED AFTER THE NEW PANEL HAS BEEN INSTALLED AND ENERGIZED.
23. PROVIDE STAINLESS STEEL SUPPORT STRUCTURE AS REQUIRED AND PROVIDE NEMA 3R FUSIBLE SAFETY DISCONNECT SWITCH NEAR ASSOCIATED CHILLER. COORDINATE THE REQUIRED INSTALLATION LOCATION IN THE FIELD. INSTALL IN LOCATION AS REQUIRED TO PROVIDE ALL CODE REQUIRED CLEARANCES AND CLEARANCES REQUIRED FOR PROPER OPERATION AND MAINTENANCE OF CHILLER. SEE ONE-LINE DIAGRAM, SHEET E3.2, FOR ADDITIONAL REQUIREMENTS. REWORK THE EXISTING ELECTRICAL INSTALLATION AROUND THE CHILLER AS
REQUIRED TO ACCOMMODATE THE PROJECT NEW CONSTRUCTION REQUIREMENTS.
24. PROVIDE POWER CIRCUIT TO SWITCH FROM 277V BRANCH CIRCUIT WHICH FED THE LIGHTING FIXTURES
WITHIN THE ROOM PRIOR TO START OF DEMOLITION.
25. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED SAW CUTTING, DIGGING, TRENCHING, BACK-FILLING, PATCHING, AND CONCRETE INSTALLATION WITH THE GENERAL CONTRACTOR.
PROVIDE ALL REQUIRED DEMOLITION AND NEW CONSTRUCTION WORK AS REQUIRED TO INSTALL NEW UNDERGROUND NORMAL POWER, EMERGENCY POWER, AND COMMUNICATION & CONTROL CIRCUITS BELOW GRADE FROM THE UTILITY TRANSFORMER AND EMERGENCY GENERATOR LOCATIONS TO THE ASSOCIATED
EQUIPMENT INSTALLED WITHIN THE BUILDING MAIN ELECTRICAL ROOM.
26. PROVIDE STRUCTURAL STEEL TYPE SUPPORT STRUCTURE AS REQUIRED TO INSTALL DISTRIBUTION EQUIPMENT. SEISMICALLY SECURE THE STRUCTURE TO THE FLOOR AT BOTTOM AND TO THE STRUCTURE WALL &
BUILDING STEEL AT TOP.
27. PROVIDE NEW PULL / JUNCTION BOXES IN CEILING CAVITY SPACE ABOVE THE OLD PANEL "B1" LOCATION AS REQUIRED TO REFED THE EXISTING LOADS FROM THE NEW PANEL "B1". THE OLD PANEL "B1" SHALL BE DISCONNECTED AND REMOVED COMPLETE. THE BACKBOX SHALL NOT BE REUSED AS A JUNCTION BOX OR PULL
BOX.
28. PAINT WALL TO MATCH FINISH COLOR OF THE ADJACENT WALL FINISH (I.E IN LOCATIONS WHERE REMOVAL
OF PANEL BACKBOX AND CONDUITS EXPOSE A DIFFERENT WALL FINISH COLOR).
29. PROVIDE STRUCTURAL STEEL TYPE SUPPORT STRUCTURE AS REQUIRED TO INSTALL CIRCUIT BREAKERS AND T.C. PANEL. SEISMICALLY SECURE THE STRUCTURE TO THE FLOOR AT BOTTOM AND TO THE STRUCTURE
WALL & BUILDING STEEL AT TOP.
30. PROVIDE DEDICATED 120V, 20A BRANCH CIRCUIT TO T.C. PANEL FROM EMERGENCY POWER PANEL "EL1(702)"
CIRCUIT NO. 3 USING 2#12, 1#12G IN 3/4"C.
31. PROVIDE "C1" DATA OUTLET NEAR T.C. PANEL FOR NETWORK CONNECTION TO T.C. PANEL. COORDINATE THE INSTALLATION LOCATION AND MOUNTING HEIGHT WITH THE REQUIREMENTS FOR THE T.C. PANEL INSTALLATION.
PROVIDE DATA CABLE FROM THE NEAREST DATA ROOM. COORDINATE ALL DATA INSTALLATION WITH THE
OWNER'S I.T. PERSON PRIOR TO START OF PROJECT.
32. INSTALL SAFETY DISCONNECT SWITCH FOR EXHAUST FAN "EF-9" (FURNISHED BY MECHANICAL CONTRACTOR & INSTALLED BY ELECTRICAL CONTRACTOR). PROVIDE POWER CIRCUIT TO EXHAUST FAN (THRU SAFETY DISCONNECT SWITCH) FROM THE SAME CIRCUIT WHICH FED AND CONTROLLED THE EXHAUST FAN PRIOR TO
START OF DEMOLITION. SEE MECHANICAL PLANS FOR ADDITIONAL REQUIREMENTS.
33. SPARE FUSE CABINET. INSTALL SPARE FUSE CABINET REMOVED FOR RELOCATION IN THIS GENERAL AREA.
34. SEE ONE-LINE DIAGRAM, SHEET E3.2, FOR ADDITIONAL REQUIREMENTS.
35. CUT-OFF / GRIND CONDUITS AT FLOOR. FILL-IN WITH CONCRETE AS REQUIRED TO PROVIDE A SMOOTH AND
SAFE WALKING SURFACE.
NOTES:
PANEL "A".
NOTE 1.
TRANSFORMER "XLDPD"
DIST PANEL "LDPD"
PANEL "D".
NOTE 1.
CIRCUIT BREAKER
"CB-LDPD"
CIRCUIT BREAKER
"CB-XLDPD"
NOTE 3
NOTE 2.
(OLD PANEL "B" LOCATION)
PANEL "B".
TRANSFORMER
"XLDPB"
DIST PANEL
"LDPB"
CIRCUIT
BREAKER
"CB-LDPB" CIRCUIT BREAKER
"CB-XLDPB"
NOTE 2.
(OLD PANEL "G" LOCATION)
PANEL "G".
NOTE 1.
NOTE 2.
(OLD PANEL "F" LOCATION)
PANEL "F".
NOTE 1.
TRANSFORMER
"XLDPF"
DIST PANEL
"LDPF"
CIRCUIT BREAKER
"CB-LDPF"
CIRCUIT BREAKER
"CB-XLDPF"
NOTE 3
NOTE 4.
(OLD PANEL
"C" LOCATION)
PANEL "C"
TRANSFORMER "XLDPJ"
DIST PANEL "LDPJ"
PANEL "J"
CIRCUIT BREAKER
"CB-LDPJ"
CIRCUIT BREAKER
"CB-XLDPJ"
NOTE 3
NOTE 5
NOTE 6
CIRCUIT BREAKER "CB-XK"
PANEL "G1"
PANEL "J1"
NOTES 10 & 28.
(OLD PANEL "F1"
LOCATION)
NOTE 4.
(OLD PANEL
"J" LOCATION)
EXISTING COMBINATION
MOTOR STARTER
"CMS-A/C OFFICE".
NOTE 12. NOTES 13 & 28.
(OLD PANEL
"D1" LOCATION) NOTE 14
EXISTING DISC. SW "TRAINER 1"
EXISTING DISC. SW "TRAINER 2"
EXISTING DISC. SW "TRAINER 3"
EXISTING DISC SW "F2"
NOTES 27 & 28.
(OLD PANEL
"B1" LOCATION)
PANEL "B1".
NOTE 15.
(OLD PANEL "H" LOCATION)
DISC SW
"DS-KILN#1".
NOTE 11.
DISC SW
"DS-KILN#2".
NOTE 11.
RTU-1
EXISTING AIR HANDLING UNIT
"RTU-1" & DISC SW "DS-RTU-1".
EXISTING
DISC SWITCH
"DS-CU-1"
EXISTING DISC SW FOR
SMALL CONDENSING UNIT
SEE ENLARGED ELEC PLAN - MEZZ RM 23,
THIS SHEET FOR ADDITIONAL
REQUIREMENTS ON MEZZANINE LEVEL.
SEE ENLARGED ELEC PLAN - MEZZ RM 25,
THIS SHEET FOR ADDITIONAL
REQUIREMENTS ON MEZZANINE LEVEL.
RELOCATED AIR
COMPRESSOR
(FINAL LOCATION)
AUTO-TRANSFER
SWITCH "ATS700"
AUTO-TRANSFER
SWITCH "ATS702"
CIRCUIT BREAKER "NCB-ATS700"
CIRCUIT BREAKER "NCB-ATS702"
CIRCUIT BREAKER "ECB-ATS702"
CIRCUIT BREAKER "ECB-ATS700"
SEE ENLARGED ELEC PLAN -
RM 24E, THIS SHEET FOR
ADDITIONAL REQUIREMENTS.
SEE ENLARGED ELEC PLAN -
RM 19E, THIS SHEET FOR
ADDITIONAL REQUIREMENTS.
SEE ENLARGED ELEC PLAN -
RM 14E, THIS SHEET FOR
ADDITIONAL REQUIREMENTS.
SEE ENLARGED ELEC PLAN - RMS
1A, 1B & 1E, THIS SHEET FOR
ADDITIONAL REQUIREMENTS.
PANELBOARD "ELDP1(700)".
PANELBOARD "ELDP1(702)".
PANEL "EL1(702)"
PANEL "EH1(702)" [NEC702]
PANEL "EH1(700)" [NEC700]
PANEL "EL1(700)"
NOTE 19
GENERATOR & ATSs REMOTE
ANNUNCIATOR PANELS.
NOTE 20.
ELEC
1E
ELEC
14E
ELEC
19E
ELEC
24E
DISCONNECT SWITCH
"DS-CHILLER #2".
NOTE 23.
DISCONNECT SWITCH
"DS-CHILLER #1".
NOTE 23.
MAIN SWITCHBOARD "MHSB"
NOTE 25
NOTE 25
NOTE 35
NOTE 35
NOTE 35
NOTE 35
NOTE 35
TRANSFORMERS "XEH1(700)" & "XEH1(702).
NOTE 18.
CIRCUIT BREAKER "CBXEH2(702)"
TRANSFORMER "XEH2(702)"
PANEL "EH2(702)"
PANEL "EL2(702)"
CIRCUIT BREAKER "CB-KLEFT"
EXISTING
TRANSFORMER
"XVET"
EXISTING DISC
SW "DSVET"
EXISTING PANEL "VET 1"
EXISTING
PANEL "VET"
EXISTING
PANEL "ZZ"
CIRCUIT BREAKER "CB-XVET".
PROVIDE SUPPORT
STRUCTURE BEHIND CIRCUIT
BREAKER AS REQUIRED
INSTALL CIRCUIT BREAKER
ABOVE THE EXISTING
TRANSFORMER WITH THE
FRONT OF THE CIRCUIT
BREAKER BEING THE SAME
DISTANCE FROM THE BLOCK
WALL AS THE FRONT OF THE
TRANSFORMER.
TRANSFORMER "XM1"
CIRCUIT BREAKER "CB-XM1"
CIRCUIT BREAKER "CB-M1"
OFFICE
1C
OFFICE
1B
OFFICE
1A
OFFICE
1D
SKILL
TRAIN
OFFICE
NOTE 2.
(OLD PANEL "D" LOCATION)
NOTE 2.
(OLD PANEL "A" LOCATION)
PANEL "A".
NOTE 1.
TRANSFORMER "XLDPD"
DIST PANEL "LDPD"
PANEL "D".
NOTE 1.
CIRCUIT BREAKER
"CB-LDPD"
CIRCUIT BREAKER
"CB-XLDPD"
NOTE 3
EX
EX
EX
EX
EX
EX
F1D F1D
F1D F1D
F2
F2
F2
ELEC
1E
PROVIDE POWER CIRCUIT TO
LIGHTING FIXTURES WITHIN THIS
ROOM FROM THE SAME BRANCH
CIRCUIT WHICH FED THE LIGHTING
FIXTURES WITHIN THIS SPACE
PRIOR TO START OF DEMOLITION.
C2
C2
C2
C2
D-38.
NOTE 22.
D-40.
NOTE 22.
NOTE 21. TYPICAL, ALL
RECEPTACLE LOCATIONS.
D-42
CIRCUIT BREAKER "CBXEH2(702)"
TRANSFORMER "XEH2(702)"
PANEL "EH2(702)"
PANEL "EL2(702)"
PROVIDE POWER CIRCUIT TO
LIGHTING FIXTURES WITHIN THIS
ROOM FROM THE SAME BRANCH
CIRCUIT WHICH FED THE LIGHTING
FIXTURES WITHIN THIS SPACE
PRIOR TO START OF DEMOLITION.
CARPENTRY
SHOP
TOOLS &
STORAGE
19A
NOTE 2.
(OLD PANEL "G" LOCATION)
PANEL "G".
NOTE 1.NOTE 2.
(OLD PANEL "F" LOCATION)
PANEL "F".
NOTE 1.
TRANSFORMER "XLDPF"
DIST PANEL "LDPF"
CIRCUIT BREAKER "CB-LDPF"
CIRCUIT BREAKER "CB-XLDPF"
NOTE 3
PANEL "G1"
F2 F2
ELEC
19E
PROVIDE POWER CIRCUIT TO LIGHTING FIXTURES
WITHIN THIS ROOM FROM THE SAME BRANCH CIRCUIT
WHICH FED THE LIGHTING FIXTURES WITHIN THIS
SPACE PRIOR TO START OF DEMOLITION.
G1-9
USE LIGHTING FIXTURE REMOVED FOR
RELOCATION. RELOCATE LIGHTING
FIXTURE AS REQUIRED TO BE FULLY
ACCESSIBLE FROM THE MEZZANINE
LEVEL. CONNECT TO CIRCUIT WHICH FED
AND CONTROLLED LIGHTING FIXTURE
PRIOR TO START OF DEMOLITION.
USE LIGHTING FIXTURE REMOVED FOR
RELOCATION. RELOCATE LIGHTING FIXTURE AS
REQUIRED TO BE FULLY ACCESSIBLE FROM THE
MEZZANINE LEVEL. CONNECT TO CIRCUIT WHICH
FED AND CONTROLLED LIGHTING FIXTURE PRIOR
TO START OF DEMOLITION.
GFI
OFFICE
14A
PANEL "B".
TRANSFORMER "XLDPD"
DIST PANEL "LDPB"
CIRCUIT BREAKER
"CB-LDPB"
CIRCUIT BREAKER "CB-XLDPB"
PANEL "B1".
F1D
F1D
F1D
F1D
F2
F2
PROVIDE POWER CIRCUIT TO LIGHTING
FIXTURES WITHIN THIS ROOM FROM THE
SAME BRANCH CIRCUIT WHICH FED THE
LIGHTING FIXTURES WITHIN THIS SPACE
PRIOR TO START OF DEMOLITION.
B1-1
GND
NOTE 3
EX
PROVIDE POWER CIRCUIT TO NEW RECEPTACLE WITHIN THIS
ROOM FROM THE SAME BRANCH CIRCUIT WHICH FED THE
RECEPTACLES IN THE ROOM PRIOR TO START OF DEMOLITION.
TYPICAL, ALL LOCATIONS, THIS ROOM.
PROVIDE DATA OUTLET AND DATA CABLE FROM THE SAME DATA
ROOM WHICH FED THE DATA OUTLET IN ROOM PRIOR TO START
OF DEMOLITION. TYPICAL, ALL LOCATIONS, THIS ROOM.
C2
EX
ELEC
14E
NOTE 2.
(OLD PANEL "B" LOCATION)
NOTE 14
CLO.
106J
DISPLAY
CASE
106I
STORAGE
24C
PANEL "C"
TRANSFORMER "XLDPJ"
DIST PANEL "LDPJ"
PANEL "J"
CIRCUIT BREAKER
"CB-LDPJ"
CIRCUIT BREAKER
"CB-XLDPJ"
PANEL "J1"
O
NOTE 3
GND
F2F2
F1D
ELEC
24E
F3D a aa b b
PROVIDE POWER CIRCUIT TO LIGHTING
FIXTURES / SWITCH WITHIN THIS ROOM
FROM THE SAME BRANCH CIRCUIT WHICH
FED THE LIGHTING FIXTURES WITHIN THIS
SPACE PRIOR TO START OF DEMOLITION.
PROVIDE POWER CIRCUIT TO LIGHTING
FIXTURES / SWITCHES WITHIN THIS ROOM
FROM THE SAME BRANCH CIRCUIT WHICH
FED THE LIGHTING FIXTURES WITHIN THIS
SPACE PRIOR TO START OF DEMOLITION.
J1-11
J1-9
J1-13
MAIN
ELEC
WOMENS
DRESSING
EAST
CORRIDOR
14K
EXISTING PANEL "R"
OLD LOCATION OF
REMOVED MAIN
SWITCHBOARD "MSB"
EXISTING TELCOM
SERVICE ENCLOSURE
RELOCATED AIR
COMPRESSOR
(TEMPORARY LOCATION)
NOTE 5
NOTE 6
RELOCATED AIR
COMPRESSOR
(FINAL LOCATION)
AUTO-TRANSFER SWITCH "ATS700"
AUTO-TRANSFER SWITCH "ATS702"
CIRCUIT BREAKER "NCB-ATS700"
CIRCUIT BREAKER "NCB-ATS702"
CIRCUIT BREAKER
"ECB-ATS702".
NOTE 26.
CIRCUIT BREAKER
"ECB-ATS700".
NOTE 26.
PANELBOARD "ELDP1(700)"
PANELBOARD "ELDP1(702)".
PANEL "EL1(702)"
PANEL "EH1(702)" [NEC702]
PANEL "EH1(700)" [NEC700]
PANEL "EL1(700)"
NOTE 19
F4
F4
F4
F4
F4
F4
F4
EH1(700)-4
EMB2
EMB2
EMB2
EMB2
a
3a
MAIN SWITCHBOARD "MHSB"
a a a a
NOTE 24
3b b b b
NOTE 25
SPACE RESERVED FOR FUTURE
SWITCHBOARD SECTION
T.C. PANEL.
NOTES 30 & 31.
NOTE 29
NOTE 32
NOTE 33
TRANSFORMERS "XEH1(700)" & "XEH1(702).
NOTE 18.
R E
NI
G
NEAN L
OI
S
E
S
F O R P
E
KENTU
C
K Y
FO
ET
A T S
D
ESNE
L I C
BROCKMAN
18703
J.
A T T
M
HE
W
REVISION HISTORY OF THIS DRAWING
DRAWING NO.
AS-BUILT DATE
DECA LOG #
DESCRIPTION OF REVISIONS DATE
DESCRIPTION OF REVISIONS DATE
DRAWING INFORMATION
A & E FILE NO.
DRAWN BY
CHECKED BY
PHASE
RTA DATE
COMMONWEALTH OF KENTUCKY
FINANCE AND ADMINISTRATION CABINET
DEPARTMENT FOR FACILITIES AND SUPPORT SERVICES
DIVISION OF ENGINEERING AND CONTRACT ADMINISTRATION
FRANKFORT, KENTUCKY
ACCOUNT NO.
DRAWING DATE
470-CB72-OC33-00
6/28/2024
06/28/2024
/1
/2
:3 :5
P
M
KCTCS - SWITCHGEAR REPLACEMENT - OWENSBORO COMMUNITY &
TECHNICAL COLLEGE - DOWNTOWN CAMPUS
MJB
6/28/2024
MJB
ELECTRICAL PLAN - FIRST FLOOR
E2.1
2401-116
"C" - RTA
1/16" = 1'-0"
ELECTRICAL PLAN - FIRST FLOOR
4'0' 8' 16'
1/16''=1'-0''
True North
Plan North
1/8" = 1'-0"
ENLARGED ELEC PLAN
- MEZZ RM 23
2'0' 4' 8'
1/8''=1'-0''
True North
Plan North
1/8" = 1'-0"
ENLARGED ELEC PLAN
- MEZZ RM 25
2'0' 4' 8'
1/8''=1'-0''
True North
Plan North
1/8" = 1'-0"
ENLARGED ELEC PLAN
- RMS 1A, 1B & 1E
2'0' 4' 8'
1/8''=1'-0''
True North
Plan North
1/8" = 1'-0"
ENLARGED ELEC PLAN
- RM 19E
2'0' 4' 8'
1/8''=1'-0''
True North
Plan North
1/8" = 1'-0"
ENLARGED ELEC PLAN - RM 14E
2'0' 4' 8'
1/8''=1'-0''
True North
Plan North
1/8" = 1'-0"
ENLARGED ELEC PLAN
- RM 24E
2'0' 4' 8'
1/8''=1'-0''
True North
Plan North
1/8" = 1'-0"
ENLARGED ELEC PLAN -
MAIN ELEC RM 153
2'0' 4' 8'
1/8''=1'-0''
True North
Plan North
ADDENDUM NO. 3 8/15/2024
| Addendum Three |
| Addendum No.3 Letter and attachments |
| Addendum No. 3 Verbage Letter |
| E1.0 Rev 2 |
| E2.1 Rev 1 |
File details come from the government source that posted it. Updated .