Construction Camp Dawson Sergeant Major's Cottage Renovation
Solicitation number
CRFQ 0603 ADJ2700000018 2
Issued by
Lewis County, West Virginia

About this file

This Addendum No. 1 document, issued by the West Virginia Department of Administration Purchasing Division, modifies a Centralized Request for Quote (CRFQ) solicitation for construction renovation services at Camp Dawson, a West Virginia Army National Guard facility in Kingwood, West Virginia. The project involves comprehensive renovations to the Sergeant Major's Cottage, including labor, materials, and associated costs to complete the work per attached drawings and specifications. A base bid for the renovation work and an alternate bid for a crawl space access door and concrete porch slab are requested. The mandatory pre-bid meeting was held on August 26, 2026 at 10:00 a.m. EST, with vendor technical questions due by September 2, 2026 at 11:00 a.m. EST. The solicitation closes on September 9, 2026 at 1:30 p.m. EST. The addendum provides pre-bid sign-in sheets, responses to vendor technical questions addressing clarifications on ceiling fans, fire alarm devices, and other specifications, and modifications to contract documents including new specification sections for foamed-in-place insulation, door hardware, and high-volume low-speed fans. The addendum also includes revised utility plans and details, updated door hardware schedules with eleven hardware groups for various door types, and a door index identifying specific hardware requirements for each door opening.

The addendum clarifies that all provisions of the solicitation not modified shall remain in full force and effect, and vendors must acknowledge receipt of all addenda to avoid bid disqualification. Key clarifications address the provision of nine ceiling fans (seven new fans with one per bedroom and two replacement fans in the living room), retention and reuse of six existing fire alarm horn/strobe devices with reassessment of reinstallation requirements, and confirmation that wood ceiling work is excluded from scope. Specification modifications include deletion of metal fabrication and pipe railing sections, addition of foamed-in-place insulation with closed-cell spray polyurethane foam meeting ASTM C1029 standards, comprehensive door hardware specifications referencing ANSI/BHMA standards with manufacturer selections from suppliers including Ives, Schlage, Von Duprin, and LCN, and high-volume low-speed ceiling fan requirements for 52-inch fans with LED lighting. The construction documents package includes detailed utility plans, electrical and mechanical control diagrams, and hardware specifications totaling multiple pages of technical requirements and installation standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date Printed: Sep 4, 2026 Page: 1 FORM ID: WV-PRC-CRFQ-002 2020/05

Department of Administration Purchasing Division 2019 Washington Street East Post Office Box 50130 Charleston, WV 25305-0130

State of West Virginia Centralized Request for Quote

Construction

Proc Folder: 2045575 Reason for Modification:

Doc Description: Construction Camp Dawson Sergeant Major's Cottage Renovation Addendum No. 1

Proc Type: Central Purchase Order

Date Issued Solicitation Closes Solicitation No Version

2026-09-04 2026-09-09 13:30 CRFQ 0603 ADJ2700000018 2

BID RECEIVING LOCATION

BID CLERK

DEPARTMENT OF ADMINISTRATION

PURCHASING DIVISION

2019 WASHINGTON ST E

CHARLESTON WV 25305

US

VENDOR

Vendor Customer Code:

Vendor Name :

Address :

Street :

City :

State : Country : Zip :

Principal Contact :

Vendor Contact Phone: Extension:

FOR INFORMATION CONTACT THE BUYER

David H Pauline 304-558-0067 david.h.pauline@wv.gov

Vendor Signature X FEIN# DATE

All offers subject to all terms and conditions contained in this solicitation

Date Printed: Sep 4, 2026 Page: 2 FORM ID: WV-PRC-CRFQ-002 2020/05

ADDITIONAL INFORMATION

Addendum No. 1

To provide copies of the prebid sign-in sheets, see attached, To provide responses to the vendor technical responses, see attached.

To provide clarifications to specifications/scope of work, see attached.

Bid opening date and time remains 9/9/2026, at 1:30 pm EST.

No other changes.

INVOICE TO SHIP TO

ADJUTANT GENERALS

OFFICE

CAMP DAWSON ARMY

TRAINING SITE

1707 COONSKIN DR 240 ARMY RD

CHARLESTON WV KINGWOOD WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 1 BASE BID: Sergeant Major's Cottage

Renovations(Construction)

Comm Code Manufacturer Specification Model #

72000000

Extended Description:

BASE BID: To provide Labor, materials and all associated costs to complete renovations to the Sergeant Major's Cottage at Camp Dawson per the attached drawings & specifications.

INVOICE TO SHIP TO

ADJUTANT GENERALS

OFFICE

CAMP DAWSON ARMY

TRAINING SITE

1707 COONSKIN DR 240 ARMY RD

CHARLESTON WV KINGWOOD WV

US US

Line Comm Ln Desc Qty Unit Issue Unit Price Total Price 2 Alternate No. 1-Provide crawl space door and concrete porch

Comm Code Manufacturer Specification Model #

72000000

Extended Description:

ALTERNATE NO. 1-To Provide crawl space access door and concrete porch slab as indicated on the drawings and specifications.

Date Printed: Sep 4, 2026 Page: 3 FORM ID: WV-PRC-CRFQ-002 2020/05

SCHEDULE OF EVENTS

Line Event Event Date 1 Mandatory Pre-bid Meeting At 10:00 am EST. 2026-08-26 2 Vendor Technical Questions Due By 11:00 am EST. 2026-09-02

SOLICITATION NUMBER: CRFQ ADJ2700000018

Addendum Number: 1

The purpose of this addendum is to modify the solicitation identified as (“ADJ2700000018”) to reflect the change(s) identified and described below.

Applicable Addendum Category:

☐ Modify bid opening date and time.

☐ Modify specifications of product or service being sought.

☒ Attachment of vendor questions and responses.

☒ Attachment of pre-bid sign-in sheet.

☒ Correction of error.

☒ Other.

Description of Modification to Solicitation:

To provide copies of the prebid sign-in sheets, see attached, To provide responses to the vendor technical responses, see attached.

To provide clarifications to specifications/scope of work, see attached.

Bid opening date and time remains 9/9/2026, at 1:30 pm EST.

No other changes.

Additional Documentation: Documentation related to this Addendum (if any) has been included herewith as Attachment A and is specifically incorporated herein by reference.

Terms and Conditions:

1. All provisions of the Solicitation and other addenda not modified herein shall remain in full force and effect.

2. Vendor should acknowledge receipt of all addenda issued for this Solicitation by completing an Addendum Acknowledgment, a copy of which is included herewith. Failure to acknowledge addenda may result in bid disqualification. The addendum acknowledgement should be submitted with the bid to expedite document processing.

Blacksburg

1116 South Main Street Blacksburg, Virginia 24060

(540) 552-2151

Charleston 222 Lee Street West

Charleston, West Virginia 25302

(304) 342-0159

Marietta 149 Acme Street, Suite A

Marietta, Ohio 45750

(740) 371-9001

Martinsburg 5550 Winchester Avenue

Berkeley Business Park, Suite 5 Martinsburg, West Virginia 25405

(304) 342-0159 www.zmm.com

TO: Prospective Bidders

FROM: ZMM, Inc. Architects and Engineers

This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents.

ATTACH THIS ADDENDUM TO THE FRONT COVER OF THE PROJECT MANUAL AND

ACKNOWLEDGE RECEIPT OF THIS ADDENDUM IN THE SPACE PROVIDED ON THE BID

FORM.

PART 1 - BIDDER’QUESTIONS AND RESPONSES

Question No. 1: Please provide panel schedule.

Response No. 1 Contractor is to field verify existing panel schedule.

Question No. 2: Who furnishes fans shown on Pg. E301? No schedule found on either Mechanical or Electrical. And to clarify, how many fans are there? E301 shows 9, but A140 shows 7.

Response No. 2 Ceiling fans are to be provided and installed by the contractor. The project includes 9 total ceiling fans - 7 new ceiling fans (1 in each bedroom) and 2 fans are new fans to replace existing (2 in the living room). See additional ceiling fan information in this addendum.

Question No. 3: There are 6 Existing Fire Alarm Horn/Strobe Devices that are calling for removal for re-use per keyed note 6, however, Pg. E401 shows 7 Fire Alarm Horn Strobes to be re-installed per Keyed note 9. Please clarify.

Response No. 3 All fire alarm devices indicated for removal in electrical demo are to be retained and reused as indicated in new work plans. Excess devices which are not being reinstalled are to be turned over to owner for attic stock. Existing fire alarm devices are not to be disposed of. All fire alarm manual pull stations and control panel shown on demo plans are existing to remain and are not being modified.

PART 2 - CLARIFICATIONS

A. WT-1 is to go full height where called out on the finish schedule.

September 4, 2026

ADDENDUM NO. 1

RE: Renovations to the Sergeant Major’s Cottage

West Virginia Army National Guard Camp Dawson Kingwood, West Virginia Architect’s Project No. 24116

Blacksburg

1116 South Main Street Blacksburg, Virginia 24060

(540) 552-2151

Charleston 222 Lee Street West

Charleston, West Virginia 25302

(304) 342-0159

Marietta 149 Acme Street, Suite A

Marietta, Ohio 45750

(740) 371-9001

Martinsburg 5550 Winchester Avenue

Berkeley Business Park, Suite 5 Martinsburg, West Virginia 25405

(304) 342-0159 www.zmm.com

B. Bathroom vanities are to have SS-1 tops.

C. All doors and wood trim are to be painted.

D. No work is to be done to the existing wood ceiling.

E. In areas where existing concrete pads are shown to be removed, the contractor is to restore the area with topsoil and lawn seed to match adjacent lawn area.

F. Under the alternate bid work, contractor is to infill the existing opening in the wall between the porch and the main crawlspace. The exposed cmu stem wall (main crawlspace exterior) to remain is to be covered in dampproofing prior to backfill. The void below the porch is to be backfilled with compacted #57 limestone placed in 6" lifts. New concrete porch elevation is to match existing deck elevation. Concrete slab to have a turn-down edge 8" wide at a depth of 36" below finished grade.

PART 3 - CHANGES TO SPECIFICATIONS

A. DELETE the following Sections:

1. Section 055000 “Metal Fabrications”.

2. Section 055213 “Pipe and Tube Railings”.

B. ADD Section 072119 “Foamed-In-Place Insulation” as attached to this Addendum.

C. ADD Section 087100 “Door Hardware” as attached to this Addendum.

D. ADD Section 233439 “High Volume, Low-Speed Fans” as attached to this Addendum.

PART 4 - CHANGES TO DRAWINGS

A. Refer to Door Index as attached to this Addendum.

B. Refer to the following revised Drawings as attached to this Addendum:

1. Sheet C300R1 – Utility Plan

2. Sheet C310R1 – Utility Details

3. Sheet M620 – Controls

END OF ADDENDUM

Attachments: Section 072119 “Foamed-In-Place Insulation .......................................... 2 pages

Section 087100 “Door Hardware” .......................................................... 29 pages Door Index ................................................................................................. 1 page Section 233439 “High-Volume, Low-Speed Fans” .................................. 6 pages Sheet C300R1 – Utility Plan ................................................................. 36” x 24” Sheet C310R1 – Utility Details ............................................................. 36” x 24” Sheet M620 – Controls ......................................................................... 36” x 24”

Sergeant Major’s Cottage Renovations

FOAMED-IN-PLACE

INSULATION – Addendum No. 1

072119 - 1 24116

SECTION 072119 - FOAMED-IN-PLACE INSULATION

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Closed-cell spray polyurethane foam insulation.

2. Accessories.

B. Related Requirements:

1. Section 072100 "Thermal Insulation" for foam-plastic board insulation.

1.2 ACTION SUBMITTALS

A. Product Data:

1. Closed-cell spray polyurethane foam insulation.

1.3 INFORMATIONAL SUBMITTALS

A. Product Test Reports: For each product, for tests performed by qualified testing agency.

B. Field quality-control reports.

C. Qualification Statements: For Installer.

1.4 QUALITY ASSURANCE

A. Installer Qualifications: An authorized representative who is trained and approved by manufacturer.

PART 2 - PRODUCTS

2.1 CLOSED-CELL SPRAY POLYURETHANE FOAM INSULATION

A. Closed-Cell Spray Polyurethane Foam: ASTM C1029, Type II, minimum density of 1.5 lb/cu.

ft. and minimum aged R-value at 1-inch thickness of 6.2 deg F x h x sq. ft./Btu at 75 deg F.

1. Provide closed-cell spray polyurethane foam insulation as manufactured by Carlisle Spray Foam Insulation or comparable products of one of the following manufacturers:

a. Huntsman Building Solutions.

b. Enverge.

http://www.specagent.com/LookUp/?ulid=11299&mf=&src=wd

FOAMED-IN-PLACE

INSULATION – Addendum No. 1

072119 - 2 24116

2. Surface-Burning Characteristics: Comply with ASTM E84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.

a. Flame-Spread Index: 75 or less.

b. Smoke-Developed Index: 450 or less.

2.2 ACCESSORIES

A. Primer: Material recommended by insulation manufacturer where required for adhesion of insulation to substrates.

PART 3 - EXECUTION

3.1 PREPARATION

A. Verify that substrates are clean, dry, and free of substances that are harmful to insulation.

B. Priming: Prime substrates where recommended by insulation manufacturer. Apply primer to comply with insulation manufacturer's written instructions. Confine primers to areas to be insulated; do not allow spillage or migration onto adjoining surfaces.

3.2 INSTALLATION

A. Comply with insulation manufacturer's written instructions applicable to products and applications.

B. Spray insulation to envelop entire area to be insulated and fill voids.

C. Apply in multiple passes to not exceed maximum thicknesses recommended by manufacturer.

Do not spray into rising foam.

D. Crawl-Spaces in Framed Construction: Install into cavities formed by framing members to achieve thickness indicated on Drawings.

E. Miscellaneous Voids: Apply according to manufacturer's written instructions.

3.3 FIELD QUALITY CONTROL

A. Manufacturer's Field Service: Engage a factory-authorized service representative to test and inspect spray foam insulation installation, including accessories. Report results in writing.

3.4 PROTECTION

A. Protect installed insulation from damage due to harmful weather exposures, physical abuse, and other causes.

END OF SECTION

DOOR HARDWARE

087100 - 1 24116

SECTION 087100 - DOOR HARDWARE

PART 1 - GENERAL

1.01 SUMMARY

A. Section includes:

1. Mechanical and electrified door hardware

2. Electronic access control system components

B. Section excludes:

1. Windows

2. Cabinets (casework), including locks in cabinets

3. Signage

4. Toilet accessories

5. Overhead doors

C. Related Sections:

1. Division 01 "General Requirements" sections for Allowances, Alternates, Owner Furnished Contractor Installed, Project Management and Coordination.

2. Division 06 Section ''Rough Carpentry''

3. Division 06 Section ''Finish Carpentry''

4. Division 07 Section ''Joint Sealants'' for sealant requirements applicable to threshold installation specified in this section.

5. Division 08 Sections:

a. ''Metal Doors and Frames''

b. ''Flush Wood Doors''

c. ''Stile and Rail Wood Doors''

d. ''Interior Aluminum Doors and Frames''

e. ''Aluminum-Framed Entrances and Storefronts''

f. ''Stainless Steel Doors and Frames''

g. ''Special Function Doors''

h. ''Entrances''

6. Division 26 ''Electrical'' sections for connections to electrical power system and for low-voltage wiring.

7. Division 28 ''Electronic Safety and Security'' sections for coordination with other components of electronic access control system and fire alarm system.

1.02 REFERENCES

A. UL LLC

1. UL 10B - Fire Test of Door Assemblies

087100 - 2 24116

2. UL 10C - Positive Pressure Test of Fire Door Assemblies

3. UL 1784 - Air Leakage Tests of Door Assemblies

4. UL 305 - Panic Hardware

B. DHI - Door and Hardware Institute

1. Sequence and Format for the Hardware Schedule

2. Recommended Locations for Builders Hardware

3. Keying Systems and Nomenclature

4. Installation Guide for Doors and Hardware

C. NFPA – National Fire Protection Association

1. NFPA 70 – National Electric Code

2. NFPA 80 – Standard for Fire Doors and Other Opening Protectives

3. NFPA 101 – Life Safety Code

4. NFPA 105 – Smoke and Draft Control Door Assemblies

5. NFPA 252 – Fire Tests of Door Assemblies

D. ANSI - American National Standards Institute

1. ANSI A117.1 – 2017 Edition – Accessible and Usable Buildings and Facilities

2. ANSI/BHMA A156.1 - A156.29, and ANSI/BHMA A156.31 - Standards for Hardware and Specialties

3. ANSI/BHMA A156.28 - Recommended Practices for Keying Systems

4. ANSI/WDMA I.S. 1A - Interior Architectural Wood Flush Doors

5. ANSI/SDI A250.8 - Standard Steel Doors and Frames

1.03 SUBMITTALS

A. General:

1. Submit in accordance with Conditions of Contract and Division 01 Submittal Procedures.

2. Prior to forwarding submittal:

a. Review drawings and Sections from related trades to verify compatibility with specified hardware.

b. Highlight, encircle, or otherwise specifically identify on submittals: deviations from Contract Documents, issues of incompatibility or other issues which may detrimentally affect the Work.

B. Action Submittals:

1. Product Data: Submit technical product data for each item of door hardware, installation instructions, maintenance of operating parts and finish, and other information necessary to show compliance with requirements.

2. Riser and Wiring Diagrams: After final approval of hardware schedule, submit details of electrified door hardware, indicating:

a. Wiring Diagrams: For power, signal, and control wiring and including:

087100 - 3 24116

1) Details of interface of electrified door hardware and building safety and security systems.

2) Schematic diagram of systems that interface with electrified door hardware.

3) Point-to-point wiring.

4) Risers.

3. Samples for Verification: If requested by Architect, submit production sample of requested door hardware unit in finish indicated and tagged with full description for coordination with schedule.

a. Samples will be returned to supplier. Units that are acceptable to Architect may, after final check of operations, be incorporated into Work, within limitations of key coordination requirements.

4. Door Hardware Schedule:

a. Submit concurrent with submissions of Product Data, Samples, and Shop Drawings.

Coordinate submission of door hardware schedule with scheduling requirements of other work to facilitate fabrication of other work critical in Project construction schedule.

b. Submit under direct supervision of a Door Hardware Institute (DHI) certified Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) with hardware sets in vertical format as illustrated by Sequence of Format for the Hardware Schedule published by DHI.

c. Indicate complete designations of each item required for each opening, include:

1) Door Index: door number, heading number, and Architect's hardware set number.

2) Quantity, type, style, function, size, and finish of each hardware item.

3) Name and manufacturer of each item.

4) Fastenings and other pertinent information.

5) Location of each hardware set cross-referenced to indications on Drawings.

6) Explanation of all abbreviations, symbols, and codes contained in schedule.

7) Mounting locations for hardware.

8) Door and frame sizes and materials.

9) Degree of door swing and handing.

10) Operational Description of openings with electrified hardware covering egress, ingress (access), and fire/smoke alarm connections.

5. Key Schedule:

a. After Keying Conference, provide keying schedule that includes levels of keying, explanations of key system's function, key symbols used, and door numbers controlled.

b. Use ANSI/BHMA A156.28 ''Recommended Practices for Keying Systems'' as guideline for nomenclature, definitions, and approach for selecting optimal keying system.

c. Provide 3 copies of keying schedule for review prepared and detailed in accordance with referenced DHI publication. Include schematic keying diagram and index each key to unique door designations.

d. Index keying schedule by door number, keyset, hardware heading number, cross keying instructions, and special key stamping instructions.

087100 - 4 24116

e. Provide one complete bitting list of key cuts and one key system schematic illustrating system usage and expansion. Forward bitting list, key cuts and key system schematic directly to Owner, by means as directed by Owner.

f. Prepare key schedule by or under supervision of supplier, detailing Owner's final keying instructions for locks.

C. Informational Submittals:

1. Provide Qualification Data for Supplier, Installer and Architectural Hardware Consultant.

2. Provide Product Data:

a. Certify that door hardware approved for use on types and sizes of labeled fire-rated doors complies with listed fire-rated door assemblies.

b. Include warranties for specified door hardware.

D. Closeout Submittals:

1. Operations and Maintenance Data: Provide in accordance with Division 01 and include:

a. Complete information on care, maintenance, and adjustment; data on repair and replacement parts, and information on preservation of finishes.

b. Catalog pages for each product.

c. Final approved hardware schedule edited to reflect conditions as installed.

d. Final keying schedule

e. Copy of warranties including appropriate reference numbers for manufacturers to identify project.

f. As-installed wiring diagrams for each opening connected to power, both low voltage and 110 volts.

E. Inspection and Testing:

1. Submit written reports to the Owner and Authority Having Jurisdiction (AHJ) of the results of functional testing and inspection for:

a. Fire door assemblies, in compliance with NFPA 80.

b. Required egress door assemblies, in compliance with NFPA 101.

1.04 QUALITY ASSURANCE

A. Qualifications and Responsibilities:

1. Supplier: Recognized architectural hardware supplier with a minimum of 5 years documented experience supplying both mechanical and electromechanical door hardware similar in quantity, type, and quality to that indicated for this Project. Supplier to be recognized as a factory direct distributor by the manufacturer of the primary materials with a warehousing facility in the Project’s vicinity. Supplier to have on staff, a certified Architectural Hardware Consultant (AHC) or Door Hardware Consultant (DHC) available to Owner, Architect, and Contractor, at reasonable times during the Work for consultation.

087100 - 5 24116

2. Installer: Qualified tradesperson skilled in the application of commercial grade hardware with experience installing door hardware similar in quantity, type, and quality as indicated for this Project.

3. Architectural Hardware Consultant: Person who is experienced in providing consulting services for door hardware installations that are comparable in material, design, and extent to that indicated for this Project and meets these requirements:

a. For door hardware: DHI certified AHC or DHC.

b. Can provide installation and technical data to Architect and other related subcontractors.

c. Can inspect and verify components are in working order upon completion of installation.

d. Capable of producing wiring diagram and coordinating installation of electrified hardware with Architect and electrical engineers.

4. Single Source Responsibility: Obtain each type of door hardware from single manufacturer.

B. Certifications:

1. Fire-Rated Door Openings:

a. Provide door hardware for fire-rated openings that complies with NFPA 80 and requirements of authorities having jurisdiction.

b. Provide only items of door hardware that are listed products tested by UL LLC, Intertek Testing Services, or other testing and inspecting organizations acceptable to authorities having jurisdiction for use on types and sizes of doors indicated, based on testing at positive pressure and according to NFPA 252 or UL 10C and in compliance with requirements of fire-rated door and door frame labels.

2. Smoke and Draft Control Door Assemblies:

a. Provide door hardware that meets requirements of assemblies tested according to

UL 1784 and installed in compliance with NFPA 105

b. Comply with the maximum air leakage of 0.3 cfm/sq. ft. (3 cu. m per minute/sq. m) at tested pressure differential of 0.3-inch wg (75 Pa) of water.

3. Electrified Door Hardware

a. Listed and labeled as defined in NFPA 70, Article 100, by testing agency acceptable to authorities having jurisdiction.

4. Accessibility Requirements:

a. Comply with governing accessibility regulations cited in ''REFERENCES'' article

087100, 1.02.D3 herein for door hardware on doors in an accessible route. This project must comply with all Federal Americans with Disability Act regulations and all Local Accessibility Regulations.

C. Pre-Installation Meetings

1. Keying Conference

a. Incorporate keying conference decisions into final keying schedule after reviewing door hardware keying system including:

087100 - 6 24116

1) Function of building, flow of traffic, purpose of each area, degree of security required, and plans for future expansion.

2) Preliminary key system schematic diagram.

3) Requirements for key control system.

4) Requirements for access control.

5) Address for delivery of keys.

2. Pre-installation Conference

a. Review and finalize construction schedule and verify availability of materials, Installer's personnel, equipment, and facilities needed to make progress and avoid delays.

b. Inspect and discuss preparatory work performed by other trades.

c. Inspect and discuss electrical roughing-in for electrified door hardware.

d. Review sequence of operation for each type of electrified door hardware.

e. Review required testing, inspecting, and certifying procedures.

f. Review questions or concerns related to proper installation and adjustment of door hardware.

3. Electrified Hardware Coordination Conference:

a. Prior to ordering electrified hardware, schedule and hold meeting to coordinate door hardware with security, electrical, doors and frames, and other related suppliers.

1.05 DELIVERY, STORAGE, AND HANDLING

A. Inventory door hardware on receipt and provide secure lock-up for hardware delivered to Project site. Promptly replace products damaged during shipping

B. Tag each item or package separately with identification coordinated with final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package. Deliver each article of hardware in manufacturer's original packaging.

C. Maintain manufacturer-recommended environmental conditions throughout storage and installation periods.

D. Provide secure lock-up for door hardware delivered to Project. Control handling and installation of hardware items so that completion of Work will not be delayed by hardware losses both before and after installation.

E. Handle hardware in manner to avoid damage, marring, or scratching. Correct, replace or repair products damaged during Work. Protect products against malfunction due to paint, solvent, cleanser, or any chemical agent.

F. Deliver keys to manufacturer of key control system for subsequent delivery to Owner.

1.06 COORDINATION

087100 - 7 24116

A. Coordinate layout and installation of floor-recessed door hardware with floor construction.

Cast anchoring inserts into concrete.

B. Installation Templates: Distribute for doors, frames, and other work specified to be factory or shop prepared. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.

C. Security: Coordinate installation of door hardware, keying, and access control with Owner's security consultant.

D. Electrical System Roughing-In: Coordinate layout and installation of electrified door hardware with connections to power supplies and building safety and security systems.

1.07 WARRANTY

A. Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within published warranty period.

1. Warranty does not cover damage or faulty operation due to improper installation, improper use or abuse.

2. Warranty Period: Beginning from date of Substantial Completion, for durations indicated in manufacturer's published listings.

a. Mechanical Warranty

1) Locks 10 years

2) Exit Devices 10 years

3) Closers 30 years

1.08 MAINTENANCE

A. Furnish complete set of special tools required for maintenance and adjustment of hardware, including changing of cylinders.

B. Turn over unused materials to Owner for maintenance purposes.

PART 2 - PRODUCTS

2.01 MANUFACTURERS

A. The Owner requires use of certain products for their unique characteristics and project suitability to ensure continuity of existing and future performance and maintenance standards.

After investigating available product offerings, the Awarding Authority has elected to prepare proprietary specifications. These products are specified with the notation: ''No Substitute.''

1. Where ''No Substitute'' is noted, submittals and substitution requests for other products will not be considered.

087100 - 8 24116

B. Approval of alternate manufacturers and/or products other than those listed as ''Scheduled Manufacturer'' or ''Acceptable Manufacturers'' in the individual article for the product category are only to be considered by official substitution request in accordance with section 01 25 00.

C. Approval of products from manufacturers indicated in ''Acceptable Manufacturers'' is contingent upon those products providing all functions and features and meeting all requirements of scheduled manufacturer's product.

D. Where specified hardware is not adaptable to finished shape or size of members requiring hardware, furnish suitable types having same operation and quality as type specified, subject to Architect's approval.

2.02 MATERIALS

A. Fabrication

1. Provide door hardware manufactured to comply with published templates generally prepared for machine, wood, and sheet metal screws. provide screws according to manufacturer’s recognized installation standards for application intended.

2. Finish exposed screws to match hardware finish, or, if exposed in surfaces of other work, to match finish of this other work including prepared for paint surfaces to receive painted finish.

3. Provide concealed fasteners wherever possible for hardware units exposed when door is closed. Coordinate with “Metal Doors and Frames”, “Flush Wood Doors”, “Stile and Rail Wood Doors” to ensure proper reinforcements. Advise the Architect where visible fasteners, such as thru bolts, are required.

B. Provide screws, bolts, expansion shields, drop plates and other devices necessary for hardware installation.

1. Where fasteners are exposed to view: Finish to match adjacent door hardware material.

C. Cable and Connectors:

1. Where scheduled in the hardware sets, provide each item of electrified hardware and wire harnesses with number and gage of wires enough to accommodate electric function of specified hardware.

2. Provide Molex connectors that plug directly into connectors from harnesses, electric locking and power transfer devices.

3. Provide through-door wire harness for each electrified locking device installed in a door and wire harness for each electrified hinge, electrified continuous hinge, electrified pivot, and electric power transfer for connection to power supplies.

2.03 HINGES

A. Manufacturers and Products:

087100 - 9 24116

1. Scheduled Manufacturer and Product:

a. Ives 5BB series

2. Acceptable Manufacturers and Products:

a. McKinney TB series

b. Best FBB series

B. Requirements:

1. Provide hinges conforming to ANSI/BHMA A156.1.

2. Provide five knuckle, ball bearing hinges.

3. 1-3/4 inch (44 mm) thick doors, up to and including 36 inches (914 mm) wide:

a. Exterior: Standard weight, bronze or stainless steel, 4-1/2 inches (114 mm) high

b. Interior: Standard weight, steel, 4-1/2 inches (114 mm) high

4. 1-3/4 inch (44 mm) thick doors over 36 inches (914 mm) wide:

a. Exterior: Heavy weight, bronze/stainless steel, 5 inches (127 mm) high

b. Interior: Heavy weight, steel, 5 inches (127 mm) high

5. 2 inches or thicker doors:

a. Exterior: Heavy weight, bronze or stainless steel, 5 inches (127 mm) high

b. Interior: Heavy weight, steel, 5 inches (127 mm) high

6. Adjust hinge width for door, frame, and wall conditions to allow proper degree of opening.

7. Provide three hinges per door leaf for doors 90 inches (2286 mm) or less in height, and one additional hinge for each 30 inches (762 mm) of additional door height.

8. Hinge Pins: Except as otherwise indicated, provide hinge pins as follows:

a. Steel Hinges: Steel pins

b. Non-Ferrous Hinges: Stainless steel pins

c. Out-Swinging Exterior Doors: Non-removable pins

d. Out-Swinging Interior Lockable Doors: Non-removable pins

e. Interior Non-lockable Doors: Non-rising pins

9. Provide hinges with electrified options as scheduled in the hardware sets. Provide with number and gage of wires enough to accommodate electric function of specified hardware. Locate electric hinge at second hinge from bottom or nearest to electrified locking component. Provide mortar guard for each electrified hinge specified.

2.04 CONTINUOUS HINGES

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Select

b. Best

087100 - 10 24116

B. Requirements:

1. Provide aluminum geared continuous hinges conforming to ANSI/BHMA A156.26, Grade 1.

2. Provide aluminum geared continuous hinges, where specified in the hardware sets, fabricated from 6063-T6 aluminum.

3. Provide split nylon bearings at each hinge knuckle for quiet, smooth, self-lubricating operation.

4. Provide hinges capable of supporting door weights up to 450 pounds, and successfully tested for 1,500,000 cycles.

5. On fire-rated doors, provide aluminum geared continuous hinges classified for use on rated doors by testing agency acceptable to authority having jurisdiction.

6. Provide aluminum geared continuous hinges with electrified option scheduled in the hardware sets. Provide with number and gage of wires enough to accommodate electric function of specified hardware.

7. Provide hinges 1 inch (25 mm) shorter in length than nominal height of door, unless otherwise noted or door details require shorter length and with symmetrical hole pattern.

2.05 MORTISE LOCKS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage L9000 series

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Requirements:

1. Provide mortise locks conforming to ANSI/BHMA A156.13 Series 1000, Grade 1, and UL Listed for 3-hour fire doors.

2. Indicators: Where specified, provide indicator window measuring a minimum 2-inch x 1/2 inch with 180-degree visibility. Provide messages color-coded with full text and/or symbols, as scheduled, for easy visibility.

3. Provide locks manufactured from heavy gauge steel, containing components of steel with a zinc dichromate plating for corrosion resistance.

4. Provide lock case that is multi-function and field reversible for handing without opening case. Cylinders: Refer to “KEYING” article, herein.

5. Provide locks with standard 2-3/4 inches (70 mm) backset with full 3/4 inch (19 mm) throw stainless steel mechanical anti-friction latchbolt. Provide deadbolt with full 1-inch (25 mm) throw, constructed of stainless steel.

6. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim.

7. Provide electrified options as scheduled in the hardware sets. Where scheduled, provide switches and sensors integrated into the locks and latches. Provide motor based electrified and motor based latch retraction locksets that comply with the following requirements:

087100 - 11 24116

a. Universal input voltage – single chassis accepts 12 or 24VDC to allow for changes in the field without changing lock chassis.

b. Fail Safe/Fail Secure – changing mode between electrically locked (fail safe) and electrically unlocked (fail secure) is field selectable without opening the lock case

c. Low maximum current draw – maximum 0.4 amps (Lever control) and maximum 2.0 amps (Latch retraction) to allow for multiple locks on a single power supply.

d. Low holding current (Lever control or latch retraction) – maximum 0.01 amps to produce minimal heat, eliminate “hot levers” in electrically locked applications and motorized latch retraction applications, and to provide reliable operation in wood doors that provide minimal ventilation and air flow.

e. Connections – provide quick-connect Molex system standard.

8. (OPTION Key Override) Provide locks with a key override feature built into the chassis that allows the outside key to retract the deadbolt and/or latchbolt, overriding the inside thumbturn when it is being held in the locked position - where the XL13-439 option is specified in the hardware sets.

9. Lever Trim: Solid brass, bronze, or stainless steel, cast or forged in design specified, with wrought roses and external lever spring cages. Provide thru-bolted levers with 2-piece spindles.

a. (OPTION Vandlgard) Provide levers with vandal resistant technology for use at heavy traffic or abusive applications.

b. Lever Design: 07.

2.06 CYLINDRICAL LOCKS – GRADE 1

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage ND series

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Requirements:

1. Provide cylindrical locks conforming to ANSI/BHMA A156.2 Series 4000, Grade 1, and UL Listed for 3-hour fire doors.

2. Indicators: Where specified, provide escutcheon with lock status indicator window on top of lockset rose:

a. Escutcheon height (including rose) 6.05 inches high by 3.68 inches wide.

b. Indicator window measuring a minimum 3.52-inch by .60 inch with 1.92 square-inches of front facing viewing area and 180-degree visibility with a total of .236 square-inches of total viewable area.

c. Provide snap-in serviceable window to prevent tampering. Lock must function if indicator is compromised.

d. Provide messages color-coded with full text and symbol, as scheduled, for easy visibility.

087100 - 12 24116

e. Unlocked and Unoccupied message will display on white background, and Locked and Occupied message will display on red background.

3. Cylinders: Refer to ''KEYING'' article, herein.

4. Provide locks with standard 2-3/4 inches (70 mm) backset, unless noted otherwise, with

1/2-inch latch throw. Provide proper latch throw for UL listing at pairs.

5. Provide locksets with separate anti-rotation thru-bolts, and no exposed screws.

6. Provide independently operating levers with two external return spring cassettes mounted under roses to prevent lever sag.

7. Provide standard ASA strikes unless extended lip strikes are necessary to protect trim.

8. Provide electrified options as scheduled in the hardware sets.

9. Lever Trim: Solid cast levers without plastic inserts and wrought roses on both sides.

a. Lever Design: ATH.

2.07 EXIT DEVICES

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Von Duprin 99/33A series

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Requirements:

1. Provide exit devices tested to ANSI/BHMA A156.3 Grade 1 and UL listed for Panic Exit or Fire Exit Hardware.

2. Cylinders: Refer to ''KEYING'' article, herein.

3. Provide grooved touchpad type exit devices, fabricated from brass, bronze, stainless steel, or aluminum, plated to standard architectural finishes to match the balance of door hardware.

4. Touchpad must extend a minimum of one-half of the door width. No plastic inserts are allowed in touchpads.

5. Provide exit devices with a deadlatching feature for security and for future addition of alarm kits and/or other electrified requirements.

6. Provide exit devices at pool gates with weather-resistant components that can withstand harsh conditions of various climates and corrosive cleaners used in outdoor pool environments.

7. Provide flush end caps for exit devices.

8. Provide exit devices with manufacturers’ approved strikes.

9. Provide exit devices cut to the door width and height. Install exit devices at a height recommended by the exit device manufacturer, allowable by governing building codes, and approved by the Architect.

10. Mount the mechanism case flush on the face of the doors or provide spacers to fill gaps behind the devices. Where glass trim or molding projects off the face of the door, provide glass bead kits.

11. Provide cylinder or hex-key dogging as specified at non-fire-rated openings.

087100 - 13 24116

12. Removable Mullions: 2 inches (51 mm) x 3 inches (76 mm) steel tube. Where scheduled as keyed removable mullion, provide a type that can be removed by use of a keyed cylinder, which is self-locking when reinstalled.

13. Provide factory-drilled weep holes for exit devices used in full exterior applications, highly corrosive areas, and where noted in hardware sets.

14. Provide electrified options as scheduled.

15. Top latch mounting: double- or single-tab mount for steel doors, face mount for aluminum doors, eliminating the requirement of tabs, and double tab mount for wood doors.

16. Accessibility: Require not more than 5 lb. to retract the latchbolt, per CBC 2019 11B-

404.2.7 and 11B-309.4.

a. Mechanical method: Von Duprin AX feature, where touchpad directly retracts the latchbolt with 5 lb. or less of force. Provide testing lab certification confirming that the mechanical device is independent third-party tested to meet this 5 lb. requirement.

b. Electrical method: Von Duprin’s RX-QEL feature, where lightly pressing the touchpad with 5 lb. or less of force closes an electric switch, activating quiet electric latch retraction.

17. Provide exit devices with optional trim designs to match other lever and pull designs used on the project.

a. Provide levers that return to within 1/2 inch (13 mm) of the door face.

2.08 ACCESS CONTROL PLATFORM

A. Manufacturers and Products:

1. Scheduled Manufacturer:

a. Dorma/Kaba/saflok

2. Acceptable Manufacturers and Products:

a. No Substitute

2.09 ELECTRIC STRIKES

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Von Duprin 6000 Series

2. Acceptable Manufacturers and Products:

a. Folger Adam 300 Series

b. HES 1006 Series

B. Requirements:

1. Provide electric strikes designed for use with type of locks shown at each opening.

2. Provide electric strikes UL Listed as burglary resistant that are tested to a minimum endurance test of 1,000,000 cycles.

087100 - 14 24116

3. Where required, provide electric strikes UL Listed for fire doors and frames.

4. Provide transformers and rectifiers for each strike as required. Verify voltage with electrical contractor.

2.10 POWER SUPPLIES

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage/Von Duprin PS900 Series

2. Acceptable Manufacturers and Products:

a. Securitron BPS series

b. Security Door Controls 600 series

B. Requirements:

1. Provide power supplies approved by manufacturer of supplied electrified hardware.

2. Provide appropriate quantity of power supplies necessary for proper operation of electrified locking components as recommended by manufacturer of electrified locking components with consideration for each electrified component using power supply, location of power supply, and approved wiring diagrams. Locate power supplies as directed by Architect.

3. Provide regulated and filtered 24 VDC power supply, and UL class 2 listed.

4. Provide power supplies with the following features:

a. 12/24 VDC Output, field selectable.

b. Class 2 Rated power limited output.

c. Universal 120-240 VAC input.

d. Low voltage DC, regulated and filtered.

e. Polarized connector for distribution boards.

f. Fused primary input.

g. AC input and DC output monitoring circuit w/LED indicators.

h. Cover mounted AC Input indication.

i. Tested and certified to meet UL294.

j. NEMA 1 enclosure.

k. Hinged cover w/lock down screws.

l. High voltage protective cover.

2.11 CYLINDERS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. Schlage Primus XP

2. Acceptable Manufacturers and Products:

a. No Substitute

087100 - 15 24116

1. Provide cylinders/cores, compliant with ANSI/BHMA A156.5; latest revision; cylinder face finished to match lockset, manufacturer’s series as indicated. Refer to “KEYING” article, herein.

2. Provide cylinders in the below-listed configuration(s), distributed throughout the Project as indicated.

a. High Security: dual-locking cylinder with permanent core requiring restricted, patented keyway. Dual-locking mechanism with interlocking finger pin(s) to check for patented features on keys.

3. Patent Protection: Cylinders/cores requiring use of restricted, patented keys, patent protected.

4. Nickel silver bottom pins.

2.12 KEYING

A. Scheduled System:

1. Existing factory registered system:

a. Provide cylinders/cores keyed into Owner’s existing factory registered keying system. Comply with guidelines in ANSI/BHMA A156.28, incorporating decisions made at keying conference.

B. Requirements:

1. Construction Keying:

a. Replaceable Construction Cores.

1) Provide temporary construction cores replaceable by permanent cores, furnished in accordance with the following requirements.

a) 3 construction control keys

b) 12 construction change (day) keys.

2) Owner or Owner’s Representative will replace temporary construction cores with permanent cores.

2. Permanent Keying:

a. Provide permanent cylinders/cores keyed by the manufacturer according to the following key system.

1) Master Keying system as directed by the Owner.

b. Forward bitting list and keys separately from cylinders, by means as directed by Owner. Failure to comply with forwarding requirements will be cause for replacement of cylinders/cores involved at no additional cost to Owner.

c. Provide keys with the following features:

1) Material: Nickel silver; minimum thickness of .107-inch (2.3mm)

2) Patent Protection: Keys and blanks protected by one or more utility patent(s).

3) Geographically Exclusive: Where High Security or Security cylinders/cores are indicated, provide nationwide, geographically exclusive key system complying with the following restrictions.

087100 - 16 24116

d. Identification:

1) Mark permanent cylinders/cores and keys with applicable blind code for identification. Do not provide blind code marks with actual key cuts.

2) Identification stamping provisions must be approved by the Architect and Owner.

3) Stamp cylinders/cores and keys with Owner’s unique key system facility code as established by the manufacturer; key symbol and embossed or stamped with “DO NOT DUPLICATE” along with the “PATENTED” or patent number to enforce the patent protection.

4) Failure to comply with stamping requirements will be cause for replacement of keys involved at no additional cost to Owner.

5) Forward permanent cylinders/cores to Owner, separately from keys, by means as directed by Owner.

e. Quantity: Furnish in the following quantities.

1) Permanent Control Keys: 3.

2) Master Keys: 6.

3) Change (Day) Keys: 3 per cylinder/core that is keyed differently

4) Key Blanks: Quantity as determined in the keying meeting.

2.13 KEY CONTROL SYSTEM

A. Manufacturers:

1. Scheduled Manufacturer:

a. Telkee

2. Acceptable Manufacturers:

a. HPC

b. Lund

B. Requirements:

1. Provide key control system, including envelopes, labels, tags with self-locking key clips, receipt forms, 3-way visible card index, temporary markers, permanent markers, and standard metal cabinet, all as recommended by system manufacturer, with capacity for 150% of number of locks required for Project.

a. Provide complete cross index system set up by hardware supplier, and place keys on markers and hooks in cabinet as determined by final key schedule.

b. Provide hinged-panel type cabinet for wall mounting.

2.14 DOOR CLOSERS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. LCN 4040XP series

2. Acceptable Manufacturers and Products:

087100 - 17 24116

a. No Substitute

1. Provide door closers conforming to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory. ISO 9000 certify closers. Stamp units with date of manufacture code.

2. Provide door closers with fully hydraulic, full rack and pinion action with high strength cast iron cylinder, and full complement bearings at shaft.

3. Cylinder Body: 1-1/2-inch (38 mm) diameter piston with 5/8-inch (16 mm) diameter double heat-treated pinion journal. QR code with a direct link to maintenance instructions.

4. Hydraulic Fluid: Fireproof, passing requirements of UL10C, and requiring no seasonal closer adjustment for temperatures ranging from 120 degrees F to -30 degrees F.

5. Spring Power: Continuously adjustable over full range of closer sizes, and providing reduced opening force as required by accessibility codes and standards. Provide snap-on cover clip, with plastic covers, that secures cover to spring tube.

6. Hydraulic Regulation: By tamper-proof, non-critical valves, with separate adjustment for latch speed, general speed, and backcheck. Provide graphically labelled instructions on the closer body adjacent to each adjustment valve. Provide positive stop on reg valve that prevents reg screw from being backed out.

7. Provide closers with solid forged steel main arms and factory assembled heavy-duty forged forearms for parallel arm closers.

8. Pressure Relief Valve (PRV) Technology: Not permitted.

9. Finish for Closer Cylinders, Arms, Adapter Plates, and Metal Covers: Powder coating finish which has been certified to exceed 100 hours salt spray testing as described in ANSI Standard A156.4 and ASTM B117, or has special rust inhibitor (SRI).

10. Provide special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting.

11. Closers shall be capable of being upgraded by adding modular mechanical or electronic components in the field.

2.15 DOOR CLOSERS

A. Manufacturers and Products:

1. Scheduled Manufacturer and Product:

a. LCN 1460 series

2. Acceptable Manufacturers and Products:

a. No Substitute

B. Requirements:

1. Provide door closers conforming to ANSI/BHMA A156.4 Grade 1 requirements by BHMA certified independent testing laboratory.

2. Provide door closers with fully hydraulic, full rack and pinion action cast iron cylinder.

087100 - 18 24116

3. Closer Body: 1-1/4-inch (32 mm) diameter, with 5/8-inch (16 mm) diameter heat-treated pinion journal.

4. Hydraulic Fluid: Fireproof, passing requirements of UL10C, and requiring no seasonal closer adjustment for temperatures ranging from 120 degrees F to -30 degrees F.

5. Spring Power: Continuously adjustable over full range of closer sizes, and providing reduced opening force as required by accessibility codes and standards.

6. Hydraulic Regulation: By tamper-proof, non-critical valves, with separate adjustment for latch speed, general speed, and backcheck.

7. Pressure Relief Valve (PRV) Technology: Not permitted.

8. Provide special templates, drop plates, mounting brackets, or adapters for arms as required for details, overhead stops, and other door hardware items interfering with closer mounting.

2.16 DOOR TRIM

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Requirements:

1. Provide push plates, push bars, pull plates, pulls, and hands-free reversible door pulls with diameter and length as scheduled.

2.17 PROTECTION PLATES

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Requirements:

1. Provide protection plates with a minimum of 0.050 inch (1 mm) thick, beveled four edges as scheduled. Furnish with sheet metal or wood screws, finished to match plates.

2. Sizes plates 2 inches (51 mm) less width of door on single doors, pairs of doors with a mullion, and doors with edge guards. Size plates 1 inch (25 mm) less width of door on pairs without a mullion or edge guards.

3. At fire rated doors, provide protection plates over 16 inches high with UL label.

087100 - 19 24116

2.18 OVERHEAD STOPS AND OVERHEAD STOP/HOLDERS

A. Manufacturers:

1. Scheduled Manufacturers:

a. Glynn-Johnson

2. Acceptable Manufacturers:

a. Rixson

b. Sargent

B. Requirements:

1. Provide overhead stop at any door where conditions do not allow for a wall stop or floor stop presents tripping hazard.

2.19 DOOR STOPS AND HOLDERS

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

B. Provide door stops at each door leaf:

1. Provide wall stops wherever possible. Provide concave type where lockset has a push button of thumbturn.

2. Where a wall stop cannot be used, provide universal floor stops.

3. Where wall or floor stop cannot be used, provide overhead stop.

4. Provide roller bumper where doors open into each other and overhead stop cannot be used.

2.20 SILENCERS

A. Manufacturers:

1. Scheduled Manufacturer:

a. Ives

2. Acceptable Manufacturers:

a. Burns

b. Trimco

087100 - 20 24116

1. Provide ''push-in'' type silencers for hollow metal or wood frames.

2. Provide one silencer per 30 inches (762 mm) of height on each single frame, and two for each pair frame.

3. Omit where gasketing is specified.

2.21 THRESHOLDS,…