This document appears to be a set of engineering drawings for a video display system. The drawings provide details on the physical specifications and installation requirements for an 8x12 foot full-color LED display. Key details include the overall dimensions, weight, mounting options, and cable routing. The display is intended for installation in the Atrium of the US Strategic Command (STRATCOM) facility at Offutt Air Force Base. There is a related federal contract opportunity to conduct an acoustic study of the Atrium and Auditorium spaces at this facility, in order to evaluate the impact of replacing the existing carpet flooring with terrazzo. The acoustic study is intended to identify mitigation techniques for any noise issues that may arise from the flooring change, particularly in the context of the proposed audio system upgrade for the Atrium.

View the file

Other files

File Type Posted
Auditorium Drawings.pdf PDF
Atrium Speaker Locations.pdf PDF
Atrium 3.jpg JPG image
Atrium COB NPN6600 Updated Set 11 2024.pdf PDF
Atrium 2.jpg JPG image
FSR FL-640P-8-B Specs and Drawing.pdf PDF
Auditorium 2.jpg JPG image
Auditorium 1.jpg JPG image
Atrium 4.jpg JPG image
atrium 1.jpg JPG image
Questions and Answers Acoustic Study Final J431 WWR.docx DOCX document
Questions and Answers Acoustic Study Final J431 WWR.pdf PDF
SOW_Atrium_Auditorium_Acoustic_Study.pdf PDF
Solicitation FA460024Q0083 Final.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRODUCT APPROVAL

1. MODEL: DAKTRONICS NPN-5200

2. QUANTITY: 1 (8WX12H)

3. FINISH: TBD

4. CUSTOMER APPROVAL: _________

5. DATE: _________

IF FINISH IS NOT SELECTED

BLACK WILL BE USE AS STANDARD FINISH

NOTE: ______________

ESTIMATED WEIGHT:

DISPLAY: 1507.2 LBS. (15.7 LBS. EACH)

MOUNT/CLADDING: 1450.7 LBS.

TOTAL WEIGHT: 2957.9 LBS.

US STRATCOM ATRIUM

A

SHEET 1 OF 5

REVDWG. NO.

A

SIZE

PROJECT:

NAME DATE

CHECKED

DRAWN

PROPRIETARY AND CONFIDENTIAL

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF AMD,

INC. ANY REPRODUCTION IN PART OR AS A

WHOLE WITHOUT THE WRITTEN PERMISSION

OF AMD, INC. IS PROHIBITED.

CLIENT:

MODTECH

A240406-8X12-FL-LEDALB 5/10/2024

PART NO: AMD_FL_LED_8X12

THIRD ANGLE PROJECTION

CV

CY

TIMING PLATE

FOR QUICK POST LOCATION

FIXED SIDE

PANELS

DETAIL CV

SCALE 1 : 8

FLOOR ANCHORS (TYP.)

1/2" X 4-1/4" CONCRETE SCREW

DETAIL CY

SCALE 1 : 8

WALL MOUNTING SLOTS

9/16" DIAMETER SLOT, TYP.

(RECOMMENDED)

OVERVIEW - A

NOTE:

STRUCTURE MUST BE ANCHORED WITH FASTENERS THAT ARE IN COMPLIANCE

WITH LOCAL BUILDING CODE AND/ OR STRUCTURAL ENGINEER'S SPECIFICATION

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

AMD, INC. ANY REPRODUCTION IN

PART OR AS A WHOLE WITHOUT THE

WRITTEN PERMISSION OF AMD, INC.

IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL 1/32

TWO PLACE DECIMAL .03

THREE PLACE DECIMAL .010

MATERIAL

FINISH

DRAWN

CHECKED

ENG APPR.

MFG.

Q.A.

DATENAME

PROJECT:

SIZE

B

DWG. NO. REV

WEIGHT: SCALE:

UNLESS OTHERWISE SPECIFIED:

5/10/2024

SHEET 2 OF 5DO NOT SCALE DRAWING

CLIENT:

P/N:

MODTECH

US STRATCOM ATRIUM

A

ALB

A240406-8X12-FL-LED

AMD_FL_LED_8X12

13.51in 343.1mm

24.01in 609.9mm

195.48

192.10 TOTAL VIEWABLE

CJ

FRONT VIEW

192.80 OVERALL STRUCTURE

BU

BOTTOM VIEW

4.00

6.00 8.00

6.00

DETAIL BU

SCALE 1 : 7

1/4" THK

STEEL PLATE

9.89

34.00

SILL

162.09

TOTAL

VIEWABLE

196.09

RIGHT VIEW

.19

.19 1.69

DETAIL CJ

SCALE 1 : 8

LED

PANELS

OVERVIEW - B

NOTE:

STRUCTURE MUST BE ANCHORED WITH FASTENERS THAT ARE IN COMPLIANCE

WITH LOCAL BUILDING CODE AND/ OR STRUCTURAL ENGINEER'S SPECIFICATION

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

AMD, INC. ANY REPRODUCTION IN

PART OR AS A WHOLE WITHOUT THE

WRITTEN PERMISSION OF AMD, INC.

IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL 1/32

TWO PLACE DECIMAL .03

THREE PLACE DECIMAL .010

MATERIAL

FINISH

DRAWN

CHECKED

ENG APPR.

MFG.

Q.A.

DATENAME

PROJECT:

SIZE

B

DWG. NO. REV

WEIGHT: SCALE:

UNLESS OTHERWISE SPECIFIED:

5/10/2024

SHEET 3 OF 5DO NOT SCALE DRAWING

CLIENT:

P/N:

MODTECH

US STRATCOM ATRIUM

A

ALB

45.61

45.61

8.42

38.21

8.42

45.61

BACK VIEW

WALL MOUNTING SLOTS (RECOMMENDED)

9/16" HOLES

ANCHOR TO WALL

OVERVIEW - C

NOTE:

STRUCTURE MUST BE ANCHORED WITH FASTENERS THAT ARE IN COMPLIANCE

WITH LOCAL BUILDING CODE AND/ OR STRUCTURAL ENGINEER'S SPECIFICATION

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

AMD, INC. ANY REPRODUCTION IN

PART OR AS A WHOLE WITHOUT THE

WRITTEN PERMISSION OF AMD, INC.

IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL 1/32

TWO PLACE DECIMAL .03

THREE PLACE DECIMAL .010

MATERIAL

FINISH

DRAWN

CHECKED

ENG APPR.

MFG.

Q.A.

DATENAME

PROJECT:

SIZE

B

DWG. NO. REV

WEIGHT: SCALE:

UNLESS OTHERWISE SPECIFIED:

5/10/2024

SHEET 4 OF 5DO NOT SCALE DRAWING

CLIENT:

P/N:

MODTECH

US STRATCOM ATRIUM

A

ALB

CBCB

FRONT VIEW

BW

RIGHT VIEW

DETAIL BW

SCALE 1 : 16

HEIGHT

ADJUSTABLE

+/- 2"

4.00

2.25

SECTION CB-CB

SCALE 1 : 8

AMD PATENED

G TUBE

CABLE ROUTING

AREA THROUGH POST

OVERVIEW - D

NOTE:

STRUCTURE MUST BE ANCHORED WITH FASTENERS THAT ARE IN COMPLIANCE

WITH LOCAL BUILDING CODE AND/ OR STRUCTURAL ENGINEER'S SPECIFICATION

THE INFORMATION CONTAINED IN THIS

DRAWING IS THE SOLE PROPERTY OF

AMD, INC. ANY REPRODUCTION IN

PART OR AS A WHOLE WITHOUT THE

WRITTEN PERMISSION OF AMD, INC.

IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL 1/32

TWO PLACE DECIMAL .03

THREE PLACE DECIMAL .010

MATERIAL

FINISH

DRAWN

CHECKED

ENG APPR.

MFG.

Q.A.

DATENAME

PROJECT:

SIZE

B

DWG. NO. REV

WEIGHT: SCALE:

UNLESS OTHERWISE SPECIFIED:

5/10/2024

SHEET 5 OF 5DO NOT SCALE DRAWING

CLIENT:

P/N:

MODTECH

US STRATCOM ATRIUM

A

ALB

Sheet1
Drawing View98
Sheet2
Drawing View114
Detail View CV (1 : 8)
Detail View CY (1 : 8)
Sheet3
Drawing View2
Drawing View80
Detail View BU (1 : 7)
Drawing View93
Detail View CJ (1 : 8)
Sheet4
Drawing View107
Sheet5
Drawing View72
Drawing View83
Detail View BW (1 : 16)
Section View CB-CB

File details come from the government source that posted it. Updated .