ACAS_LS_Life Safety Plan-LS1.0.pdf

PDF 707 KB Posted

Attached to
New Anderson County Animal Shelter
Solicitation number
2609
Issued by
Anderson County, Tennessee

About this file

This document is a Life Safety Plan (LS1.0) architectural floor plan for the Anderson County Animal Shelter, prepared by Blankenship & Partners, LLC, located in Knoxville, Tennessee. The detailed floor plan shows a comprehensive layout for an animal shelter facility, including multiple kennel areas, administrative spaces, veterinary zones, and circulation paths. The drawing is part of a set of professional architectural and engineering documents, with consultants including Vreeland Engineers, Inc., Welroc Enterprises, LLC, and Stanley D. Lindsey & Associates providing supporting technical expertise.

The floor plan reveals a complex, multi-zoned building design with distinct areas for animal housing, staff workspaces, medical treatment, and facility support functions. The drawing includes precise measurements, grid lines, and notations indicating space allocations for different purposes, such as kennels for different numbers of animals (ranging from 1 to 5 persons/animals per space) and various travel distances between functional areas. The project number is 18-04, and the document is dated 5-30-25, suggesting a recent design for a modern animal shelter facility with careful consideration of animal welfare and operational efficiency.

View the file

Other files

File Type Posted
ACAS_G0.0_Cover sheet-SHEET.pdf PDF
ACAS_A2.2_Roof Plan-A2.2.pdf PDF
2609 Animal Shelter Bid Packet.pdf PDF
2609 - Envelope Cover _ AC Attachments.pdf PDF
ACAS_A1.0_Site Plan-A1.0.pdf PDF
2609 Drawings.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

107 108 109 110

114A115

116 117

121122

123 124

114B

131132

129130

B

E

108 97 13

A

64 5

D

F

G

C

A

B

C

30'-6"

10.5

12'-4"

'-4

12'-4" 12'-4"

'-0

11'-4"

16'-10"

'-1

01 2"

'-8

11'-4"

'-1

12'-4"12'-4"

D

13 1411.5

18'-4"

'-0

12'-4"

14'-0"

G

18'-4"

321 3.9

31 2

18'-8"

3.9

E.1

'-2

18'-8" 14'-0"

9.5

E.5

0.5

5.1 3"

H

2 PERSON

1 PERSON

1 PERSON

1 PERSON

43'- 6" Travel to F.E.

61'-10" Travel

90'- 6" Travel

55'- 8" Travel

43'-6" Travel

FE-1

FE-1

FE-1

FE-1

FE-1

FE-1 FE-1

FE-1

20' - 10" Travel to F.E.

29'-3" Travel to F.E.

55'- 6" Travel to F.E.

44'- 5" Travel to F.E. 47'- 3" Travel to F.E.

144A 144B

109108107

106A

106B

117116

115 114A

144C

125 127

128A

128B

129130

131A

131B

143A140A

140B

139A

114B

56'- 9" CPT

61'-2" CPT

59'-10" CPT

39'- 10" CPT

5 PERSON

4 PERSONS

2 PERSON

2 PERSON

1 PERSON

1 PERSON

2 PERSON

2 PERSON

2 PERSON

1 PERSON

2 PERSON 1 PERSON 1 PERSON 1 PERSON 1 PERSON

2 PERSON

2 PERSON

1 PERSON

2 PERSON

3 PERSON

2 PERSON1 PERSON1 PERSON

1 PERSON

1 PERSON

3 PERSON

4 PERSON1 PERSON

1 PERSON

1 PERSON

13 PERSON

2 PERSON

3 PERSON

1 PERSON 1 PERSON

2 PERSON3 PERSON

1 PERSON

2 PERSON

1 PERSON

1 PERSON

79'- 4" Travel

29'-0" Travel to F.E.

29'-8" Travel to F.E.

66'- 4" Travel

23' - 10" Travel

33'- 10" Travel to F.E.

84'-8" Travel

FE-1

9'-3" Travel to F.E.

29'-7" Travel to F.E.

42'-3" Travel

FIRE

EXTINGUISHERS

B R

A C

K E

T

M

O U

N T

E D

LIFE SAFETY PLAN

LS1.0

Blankenship & Partners, LLC

1112 Weisgarber Rd, Knoxville, TN 37909

Checked By:

Drawn By:

Date:

Project Number:

Structural

Drawing No.:

SealSeal

C

Revisions Date:No.

Drawing Title:

Mechanical/Plumbing/Fire Protection

18-04

COPYRIGHT Blankenship & Partners, LLC This drawing is the property of Blankenship & Partners, LLC and shall not be reproduced in whole or in part. It shall not be used for any other project. This drawing is an instrument of service only and shall be returned to the Architect upon request.

Contact Name:

Contact Name:

Architects and Planners

Office: 865.251.2585

Project Name:

Owner:

100 N Main Street, Suite 208

Contact Name: Mayor Terry Frank

Contact Name: William R. Blankenship

Consultants:

5-30-25

RMS

WRB

Electrical

Contact Name: Chris Lay, P.E.

T [865] 745-4401

Knoxville, TN 37939

P.O. Box 10645

Vreeland Engineers, Inc.

Contact Name:

Civil

Anderson County

Clinton, Tennessee 37716

T [865] 457-6200

ANDERSON

COUNTY

ANIMAL

SHELTER

Randy Corlew, P.E.

T (423) 312.8371

Morristown, Tennessee 37814

376 Lochmere Drive

Welroc Enterprises, LLC

Jason D. Perry, P.E., S.E.

T (615) 320-1735

Brentwood, Tennessee 37027

750 Old Hickeory Blvd Building 1 Suite 175

Stanley D. Lindsey & Associates

T (865) 522-0393

Knoxville, Tennessee 37915

900 E Hill Ave. #350

Engineering Services Group

Rusty Whillock, P.E.

LS1 Scale: 1/8" = 1'-0"

FLOOR PLAN

LS1 Scale: 1/4" = 1'-0"

MOUNTING HEIGHT

B - BUSINESS @ 150 SF/PERSON

TOTAL OCCUPANCY 89 PERSONS

EGRESS LEGEND

DOOR NUMBER

TOTAL PERSONS EXITING AT DOOR

DOOR EGRESS CAPACITY (@.2 in. per occ.)

DIRECTION OF PERSONS EXITING

FIRE EXTINGUISHER LEGEND

MAX. TRAVEL DISTANCE:

300 FT (with sprinkler system)

COMMON PATH OF TRAVEL (CPT)

MAX. COMMON PATH OF TRAVEL:

75 feet (For areas serving less than 50 occupants)

PATH OF TRAVEL TO FIRE EXTINGUISHER

MAX. TRAVEL DISTANCE: 75'

FE-1 TYPE B (CLASS ABC) CO2 WITH WALL MOUNTED

BRACKET SEE 2/LS1 FOR MOUNTING HEIGHT

ADA LEGEND

INDICATES AREA NEEDED AROUND DOOR

1. 13974.5 GROSS SF OF AREA

2. 1017.2 EXIT ACCESS TRAVEL DISTANCE 300'

(W SPRINKLER SYSTEM)

GENERAL NOTES

START LOCATION OF PERSON

INDICATES 5' TURNING AREA

File details come from the government source that posted it. Updated .