ACAS_A2.2_Roof Plan-A2.2.pdf
PDF 374 KB Posted
- Attached to
- New Anderson County Animal Shelter
- Solicitation number
- 2609
- Issued by
- Anderson County, Tennessee
About this file
This document is a structural roof plan drawing for the Anderson County Animal Shelter located in Clinton, Tennessee, prepared by Blankenship & Partners, LLC. The architectural drawing (A2.2) provides a detailed roof plan at a scale of 1/8" = 1'-0", showcasing the roof's layout, including multiple roof sections with various triangular and geometric configurations. The drawing includes technical annotations, grid lines, and references to other related drawing sheets (such as A5.1, A5.2, A2.3). The project involves the design and structural planning for a new animal shelter facility, with the drawing specifically focusing on the roof's technical specifications and architectural details. The document includes contact information for the architectural firm, project owner (Anderson County), and several consulting engineering firms involved in the project.
The drawing provides precise measurements and technical details about the roof's structure, including an access ladder, ridge points, and multiple roof sections. The design appears to incorporate complex roof geometries with multiple angles and potential drainage considerations. The project is being managed by Blankenship & Partners, LLC, with multiple consulting engineers involved, including Vreeland Engineers, Inc., Stanley D. Lindsey & Associates, and other specialized engineering services. The drawing is part of a comprehensive set of architectural and engineering documents for the Anderson County Animal Shelter project, indicating a professional, methodical approach to the facility's design and construction.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B
E
108 97 13
A
64 5
D
F
G
C
A
B
C
10.5
D
13 1411.5
G
321 3.9
31 2 3.9
E.1
H
9.5
E.5
0.5
5.1
ACCESS LADDER
3'-0"
3' -0
3'-0"
7'-0" 7'-0"
2'-0" 2'-0"
3' -0
3' -0
3' -0
3' -0
3' -1
3'
-1
2'-0"
3' -0
4' -9
4"2'-0"
3' -1
4' -2
1 2"
4' -9
4"
4' -2
1 4"
20'-0" 20'-0" 30'-0" 55'-4" 19'-6"
EQEQEQEQ
36'-7"
A2.2
A2.2
A2.2
A2.2
RIDGE
A5.2
A5.0
A5.3
A5.3
A5.4
A5.3
A5.3
SIM.
A5.4
A5.1
A5.2
A5.4
SIM.
A5.2
A5.2
A5.1
RIDGE
R.D.R.D.
R.D.
A5.7
A5.1
A5.7
A5.7
SIM.
16"
53°
53°
A5.8
A5.8
A5.8
A2.3
A2.3
A5.2
STANDING SEAM ROOF
W/ 30# FELT ON ROOF
DECK
PRE-FINISHED METAL HIP
FLASHING TO MATCH
ROOF
VENT (BLOCK OVER
SEMI-HEATED SPACES)
Z-BAR
PAN ENDING PANEL TYP. @ HIP
6" MIN
STANDING SEAM ROOF
W/ 30# FELT ON
DECKING
J-CHANNEL
30# FELT FLASHING
24 GA PRE-FINISHED METAL
FLASHING TO MATCH ROOF
6" M
IN
4" MIN
6" M
IN
SIDING PANELS
Roof Plan
A2.2
Blankenship & Partners, LLC
1112 Weisgarber Rd, Knoxville, TN 37909
Checked By:
Drawn By:
Date:
Project Number:
Structural
Drawing No.:
SealSeal
C
Revisions Date:No.
Drawing Title:
Mechanical/Plumbing/Fire Protection
18-04
COPYRIGHT Blankenship & Partners, LLC This drawing is the property of Blankenship & Partners, LLC and shall not be reproduced in whole or in part. It shall not be used for any other project. This drawing is an instrument of service only and shall be returned to the Architect upon request.
Contact Name:
Contact Name:
Architects and Planners
Office: 865.251.2585
Project Name:
Owner:
100 N Main Street, Suite 208
Contact Name: Mayor Terry Frank
Contact Name: William R. Blankenship
Consultants:
5-30-25
RMS
WRB
Electrical
Contact Name: Chris Lay, P.E.
T [865] 745-4401
Knoxville, TN 37939
P.O. Box 10645
Vreeland Engineers, Inc.
Contact Name:
Civil
Anderson County
Clinton, Tennessee 37716
T [865] 457-6200
ANDERSON
COUNTY
ANIMAL
SHELTER
Randy Corlew, P.E.
T (423) 312.8371
Morristown, Tennessee 37814
376 Lochmere Drive
Welroc Enterprises, LLC
Jason D. Perry, P.E., S.E.
T (615) 320-1735
Brentwood, Tennessee 37027
750 Old Hickeory Blvd Building 1 Suite 175
Stanley D. Lindsey & Associates
T (865) 522-0393
Knoxville, Tennessee 37915
900 E Hill Ave. #350
Engineering Services Group
Rusty Whillock, P.E.
A2.2 Scale: 1/8" = 1'-0"
ROOF PLAN
A2.2 Scale: 3" = 1'-0"
ROOF DETAIL
A2.2 Scale: 3" = 1'-0"
ROOF DETAIL
N
File details come from the government source that posted it. Updated .