This document is an Ordering Data Sheet for a Nine Nuclide Gamma Calibration Source. The source is a 500 ml solid epoxy matrix containing a mixture of 9 radionuclides in specific activity ratios. The total source activity shall be 3.0 microcuries (-15%, +0%) with each nuclide's reported radioactivity uncertainty not exceeding 5% at the 99% confidence level. Surface contamination levels must be less than 450 pCi/100cm^2. The vendor must ensure the source activity is not greater than the exempt quantity per 10 CFR 30. A Certificate of Calibration is required, with the source being NIST traceable.

The related federal contract opportunity is a Pre-Solicitation for a Gamma Radioactive Source, to be solicited as a 100% Small Business set-aside using FAR Part 12 and 13 procedures. Solicitation N4523A-24-Q-4072 will be posted to SAM.gov on or about 13 August 2024, with quotes due on or about 23 August 2024. The anticipated contract will be a commercial, Firm Fixed-price Supply Contract awarded by the Naval Sea Systems Command (NAVSEA) Contracting Department for the Puget Sound Naval Shipyard and Intermediate Maintenance Facility (PSNS & IMF).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ORDERING DATA SHEET – GENERAL

NOUN NAME: RADIOACTIVE SOURCE

DESCRIPTION:

1 ea Nine nuclide gamma calibration source in the form of 500 ml solid epoxy matrix in customer provided 500 ml bottle.

-Nuclide mixture: Cd-109, Co-57, Te-123m, Cr-51, Sn 113, Sr-85, Cs-137, Y-88, Co-60 with nuclide activity ratios selected to provide similar count rates on typical coaxial high-purity germanium detectors.

-Active volume: 500 ml -Density of solid: 1.0 g/cc.

-Total source activity shall be 3.0 microcuries (–15%, +0%) -The vendor must insure that the source activity is not greater than exempt quantity per 10 CFR 30.

-The reported radioactivity uncertainty of each nuclide shall not exceed ± 5% at the 99% confidence level.

-Surface contamination levels on the source and packing materials must be less than 450 pCi/100cm^2.

MATERIAL: N/A

MANUFACTURER/VENDOR P/N: N/A

QUANTITY: 1 each

ADDITIONAL NOTES:

CERTIFICATION

-A Certificate of Calibration is required for the source and shall be provided from the vendor that documents:

-The source shall be National Institute of Standards and Technology (NIST) traceable -The total activity of the source, reference time, and date -The activity, gamma emission rate, and associated uncertainty of each nuclide -The activity of any gamma emitting impurities detected -Density and volume of active volume -The vendor assigned source serial number -ISO Classification -The results and date of leakage testing

SHIPPING REQUIREMENTS

Source will be shipped by vendor to:

(N35620) Puget Sound Naval Shipyard & IMF Detachment Naval Base Coronado Roe Street, Building 72 San Diego, CA 92135-7029 Attn: C/2380.4R - R. Nicole Van Den Eijkel (360) 801-6048

POC: C/105.84 ALAN BRUMMET (619) 634-2965

Prior to shipping, vendor will make voice contact via phone with Nicole Van Den Eijkel or their representative at (360) 476-3520 with date of shipment and shipment tracking information (i.e. UPS/FEDEX tracking numbers). A phone message will not be considered voice contact.

Changes to specification or other technical requirements are not allowed without Shipyard approval via the Administrative Contracting Officer (ACO).

JOB ORDER

991566SOUR

KEY OP

H01

KO ITEM

REV

IDN

4152VL08

IDN REV

2305.3 Form; Rev 02/2020