This document is a Performance Specification for door hardware requirements as part of a federal contract opportunity. The key details are:

The specification covers commercial and electrified door hardware for the repair and upgrade of six (6) existing exterior aluminum storefront doors at the BLM Wyoming Casper National Historic Trails Interpretive Center. Requirements include door closers, electrical accessories, and hardware finishes. The solicitation number is 140L6224Q0049 and the contract period of performance is 9/3/24 to 11/30/2024. The procurement is being conducted under FAR Part 12 - Commercial Items and FAR Part 13 - Simplified Acquisition Procedures. Offerors must be registered in SAM.gov and invoicing/payment will be through IPP.gov with 30-day prompt payment. The evaluation criteria are provided in FAR clause 52.212-2.

View the file

Other files

File Type Posted
Questions_Addressed_0004.docx DOCX document
Sol_140L6224Q0049_Amd_0004.pdf PDF
Sol_140L6224Q0049_Amd_0003.pdf PDF
Sol_140L6224Q0049_Amd_0002.pdf PDF
Sol_140L6224Q0049_Amd_0001.pdf PDF
A06_3_Attachment_C_-_BLM_Codes_and_Standards.pdf PDF
A04_Casper_NHTIC_-_Door_Upgrade_SOW_-_080924.pdf PDF
B03_Wage_Determination.pdf PDF
Sol_140L6224Q0049.pdf PDF
Bid_Schedule.xlsx XLSX spreadsheet
A06_1_Attachment_A_-_Reference_Plans.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Casper NHTIC

Door Repair & Upgrade

SECTION C40

DOORS AND HARDWARE PAGE 1

ATTACHMENT B - SECTION C40 PERFORMANCE SPECIFICATION

DOOR HARDWARE

PART 1 GENERAL

1 .1 SUMMARY

A. This section consists of Door Hardware:

1. Commercial door hardware and electrified door hardware as shown or specified for both exterior and interior doors.

1 .2 REFERENCES

A. Use date of standard or code in effect.

B. State and Local Codes including Authority Having Jurisdiction.

C. ANSI/BHMA A156 – Builders Hardware Manufacturers Association Builders Hardware Standards.

D. NFPA – National Fire Protection Association:

1. NFPA 80 – Fire Doors and Windows.

2. NFPA 101 – Life Safety Code.

E. UL – Underwriters Laboratories:

1. UL 1784 - Air Leakage Tests of Door Assemblies.

F. ANSI A117.1 – Accessible and Usable Buildings and Facilities.

G. ADA – Americans with Disabilities Act.

H. DHI – Door and Hardware Institute.

I. WDMA – Window and Door Manufacturers Association.

1 .3 GENERAL REQUIREMENTS

A. Requirements of Regulatory Agencies:

1. Furnish finish hardware to comply with the requirements of laws, codes, ordinances, and regulations of the governmental authorities having jurisdiction where such requirements exceed the requirements of the Specifications. Furnish finish hardware to comply with the requirements of the American National Standards for Making Buildings and Facilities Accessible to and Usable by Physically Handicapped People (ICC/ANSI A117.1) and to comply with Americans with Disabilities Act (ADA).

B. Source Limitations: Obtain each type and variety of door hardware from a single manufacturer, unless otherwise indicated.

SECTION C40

DOORS AND HARDWARE PAGE 2

C. Provide electrified door hardware from same manufacturer as mechanical door hardware, unless otherwise indicated. Manufacturers that perform electrical modifications and that are listed by a testing and inspecting agency acceptable to authorities having jurisdiction are acceptable.

D. Coordination

1. Furnish hardware items of proper design for use on doors and frames of thicknesses, profile, swing, security, and other indicated requirements as necessary for proper function.

2. Electrical System Roughing-in: Coordinate layout and installation of electrified door hardware with connections to power supplies, fire alarm system and detection devices and access control system.

1 .4 WARRANTY

A. Doors

1. General Warranty: Special warranties specified in this Article shall not deprive Owner of other rights Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by Contractor under requirements of the Contract Documents.

2. Special Warranty: Written warranty, executed by manufacturer agreeing to repair or replace components of door hardware that fail in materials or workmanship within specified warranty period. Failures include, but are not limited to, the following:

a. Structural failures including excessive deflection, cracking, or breakage.

b. Faulty operation of operators and door hardware.

c. Deterioration of metals, metal finishes, and other materials beyond normal weathering.

3. Warranty Period: 2 years from date of Substantial Completion, unless otherwise indicated.

1 .5 QUALITY ASSURANCE

A. Door Hardware Supplier Qualifications: Experienced commercial door hardware distributors with a minimum 5 years documented experience supplying both mechanical and electromechanical hardware installations comparable in material, design, and extent to that indicated for this Project.

Supplier recognized as a factory direct distributor by the manufacturers of the primary materials with a warehousing facility in Project's vicinity.

B. Commissioning:

1. The General Contractor in conjunction with the lock manufacturer’s representative, hardware installer and supplying distributor shall commission hardware.

a. Test door hardware operation with climate control system both at rest and while in full operation.

b. Test electrical and electronic hardware systems for satisfactory operation.

SECTION C40

DOORS AND HARDWARE PAGE 3

c. Test hardware interfaced with fire/life-safety system for proper operation and release.

1 .6 COMPLIANCE VERIFICATION

A. Specifications and design calculations shall be submitted during the design process as specified below and as specified in the project Statement of Work. Compliance with the various codes and design criteria will be determined by a review of the design calculations and specifications, construction submittals submitted during construction, and by field inspection. Compliance review is to verify that the Contractor is providing systems, products, and/or materials that will satisfy the stated criteria. This review shall not relieve the Contractor from responsibility for any errors or omissions nor from responsibility for complying with the requirements of this contract.

1 .7 SUBMITTALS DURING CONSTRUCTION

A. Submit the following for review and approval in accordance with the Design Build Project Scope Paragraph “Submittals During Construction”.

B. Manufacturer’s Catalog Data:

1. Door hardware, with schedule:

a. Door Hardware Schedule: Prepared by or under the supervision of supplier, detailing fabrication and assembly of door hardware, as well as procedures and diagrams.

Coordinate the final Door Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.

b. Details of electrified access control hardware indicating the following:

1) Wiring Diagrams: Upon receipt of approved schedules, submit detailed system wiring diagrams for power, signaling, monitoring, communication, and control of the access control system electrified hardware. Differentiate between manufacturer-installed and field-installed wiring. Include the following:

a) Elevation diagram of each unique access controlled opening showing location and interconnection of major system components with respect to their placement in the respective door openings.

b) Complete (risers, point-to-point) access control system block wiring diagrams.

c) Wiring instructions for each electronic component scheduled herein.

2) Electrical Coordination: Coordinate the voltages and wiring details required at electrically controlled and operated hardware openers.

c. Source Limitations: Obtain each type and variety of door hardware specified in this section from a single source unless otherwise indicated.

1) Electrified modifications or enhancements made to a source manufacturer's product line by a secondary or third-party source will not be accepted.

SECTION C40

DOORS AND HARDWARE PAGE 4

2) Provide electromechanical door hardware from the same manufacturer as mechanical door hardware, unless otherwise indicated.

PART 2 SYSTEM COMPONENTS

2 .1 HARDWARE

A. Door Closures

1. All door closers specified herein shall meet or exceed the following criteria:

a. General: Door closers to be from one manufacturer, matching in design and style, with same type door preparations and templates regardless of application or spring size. Closers to be non-handed with full sized covers including installation and adjusting information on inside of cover.

b. Standards: Closers to comply with UL-10C for Positive Pressure Fire Test and be U.L. listed for use of fire rated doors.

c. Cycle Testing: Provide closers which have surpassed 15 million cycles in a test witnessed and verified by UL.

d. Size of Units: Comply with manufacturer's written recommendations for sizing of door closers depending on size of door, exposure to weather, and anticipated frequency of use. Where closers are indicated for doors required to be accessible to the physically handicapped, provide units complying with ANSI ICC/A117.1.

e. Closer Arms: Provide heavy duty, forged steel closer arms unless otherwise indicated in Hardware Sets.

f. Closers shall not be installed on exterior or corridor side of doors; where possible install closers on door for optimum aesthetics.

g. Closer Accessories: Provide door closer accessories including custom templates, special mounting brackets, spacers and drop plates as required for proper installation. Provide through-bolt and security type fasteners as specified in the hardware sets.

2. Door Closers, Surface Mounted (Large Body Cast Iron): ANSI/BHMA A156.4, Grade 1 surface mounted, heavy duty door closers with complete spring power adjustment, sizes 1 thru 6; and fully operational adjustable according to door size, frequency of use, and opening force. Closers to be rack and pinion type, one-piece cast iron body construction, with adjustable backcheck and separate non-critical valves for closing sweep and latch speed control.

a. Manufacturers:

1) LCN Closers (LC) – 4600 Electronic Low Energy Operator, or Approved Alternate.

B. Electric Accessories

1. Power Supplies: Provide Nationally Recognized Testing Laboratory Listed 12VDC or 24VDC (field selectable) filtered and regulated power supplies. Include battery backup

SECTION C40

DOORS AND HARDWARE PAGE 5

option with integral battery charging capability in addition to operating the DC load in event of line voltage failure. Provide the least number of units, at the appropriate amperage level, sufficient to exceed the required total draw for the specified electrified hardware and access control equipment.

C. Finishes

1. Standard: Designations used in the Hardware Sets and elsewhere indicate hardware finishes complying with ANSI/BHMA A156.18, including coordination with traditional U.S.

finishes indicated by certain manufacturers for their products.

2. Provide quality of finish, including thickness of plating or coating (if any), composition, hardness, and other qualities complying with manufacturer's standards, but in no case less than specified by referenced standards for the applicable units of hardware.

3. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

D. Provide other finish hardware as necessary for door function and location.

--- END OF SECTION ---