936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_387-430.pdf

PDF 9 MB Posted

Attached to
Y1PC--Western New York National Cemetery Phase 1B
Solicitation number
36C10F21R0016
Issued by

About this file

This federal solicitation is for the construction of additional burial facilities and infrastructure at the Western New York National Cemetery in Corfu, NY. The project will develop approximately 30 acres of undeveloped land to provide around 9,942 new gravesites over two phases of construction. Phase 1B, which is the subject of this solicitation, will construct facilities and infrastructure to support added maintenance, operations, and burial capacity for approximately 10 years. This includes developing new burial sections with around 10 years of capacity. The Department of Veterans Affairs Office of Construction and Facilities Management is the issuing agency. Responses are due by the date listed in the solicitation, with the anticipated award date also provided. Pricing will be on a firm fixed price basis.

View the file

Other files

File Type Posted
36C10F21R0016 Questions and Responses.pdf PDF
312000_EarthMoving.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_000-022_REVISED.pdf PDF
380_936CM2002AE313.pdf PDF
WNYNC-6.01.21- Phase 1B Sign in Sheet-Final.pdf PDF
936CM2002-WNYNC1B-AMENDMENT-1.pdf PDF
090_936CM2002CP501.pdf PDF
024_936CM2002GC100_30x42.pdf PDF
315_936CM2002LI107.pdf PDF
010001_GenReq-FINALr1.pdf PDF
36C10F21R0016 0001.docx DOCX document
WNY Phase 1B Pre-Proposal Conference slides-Final.pptx PPTX presentation
325_936CM2002LI503.pdf PDF
ATTACHMENT 2 - PAST PERFORMANCE QUESTIONNAIRE.docx DOCX document
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_302-329.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_096-137.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_000-022.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_230-281.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-SPECIFICATION-VOL2.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_208-229.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_077-080.pdf PDF
36C10F21R0016_1-5-19-2021.docx DOCX document
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_052-076.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_023-034.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-SPECIFICATION-VOL1.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_282-301.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_139-164.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_332-383.pdf PDF
Genesee County Wage Decision 3-12-21.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_081-095.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_188-207.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_035-051.pdf PDF
936CM2002-WNY-NAT-CEM-PH1B_BID-DWG_165-187.pdf PDF
ATTACHMENT 3 - Pre-Proposal Inquiry (PPI) Form.docx DOCX document
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T H

R O

A T

D

IM

E

Q U

A L S

P A

R T

IT

IO

N T

H

IC

K N

E S

S P

L U

S

/8

(T Y

P

/2

V A

R

IE

S

4" 3/4"

/2

F

DOOR PANEL TYPESHM FRAME TYPES

HM-03

OPENING

WIDTH

H E

IG

H

T

1/AE602

TYP

1/AE602

TYP

1/AE602

TYP

4"

LIMESTONE SILL

TRIM BOARD

PLYWOOD

SHEATHING

CEMENT BOARD

SIDING

6" MTL STUD

FRAMING

AIR BARRIER ON

PLYWOOD

5/8" GWB

DOOR AS SCH

HM FRAME GROUTED FULL

TRIM BOARD BELOW

LIMESTONE SILL TO

TERMINATE STONE VENEER

ARIS LINE OF STONE

VENEER BELOW

3/4"

3/8"

4"

2 1/2" METAL STUD

TRIM BOARD

CEMENT BOARD SIDING

TRIM BOARD 6" MTL STUD HEADER

5/8" GWB

2 1/2" MTL STUD

HM FRAME

GROUTED FULL

/4

/8

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/1

/2

:3

:2

A

M C

U s e rs

\K C

W ill ia m s \A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

A

R P h a s e

B k c w ill .r v t

AE602

DOOR SCHEDULE, TYPES AND DETAILS

BFH KCW

DOOR SCHEDULE, TYPES AND DETAILS

3" = 1'-0"

HM FRAME PROFILE

1/4" = 1'-0"

DOOR SCHEDULE

OPENING

NUMBER

DOOR FRAME SCHEDULE

FIRE

RATING STC

HARDWARE

GROUP COMMENTSOPENING WIDTH

OPENING

HEIGHT

PANEL A

TYPE

PANEL A

WIDTH PANEL B TYPE

PANEL B

WIDTH THICKNESS MATERIAL

GLAZING

TYPE

MATERIAL &

TYPE

GLAZING

TYPE

B-E001 6' - 0" 7' - 0" F 3' - 0" F 3' - 0" 1 3/4" HM - HM-03 - - 16 INSULATED

DOOR

1/4" = 1'-0"

1 1/2" = 1'-0"

COMMITTAL SHELTER- HM DOOR JAMB DETAIL

1 1/2" = 1'-0"

COMMITAL SHELTER - HM DOOR HEAD DETAIL

BID OPTION #2

3"

SCALE : 3" = 1'-0"

0 6" 9"

1'

SCALE : 3/4" = 1'-0"

0 2' 3'

NORTH

4 8 1608

1 inch = 8 feet

GRAPHIC SCALE

1.B 2B

A.B

D.B

B.B

C.B

1.2B 1.5B

1.4B

1.3B

4" STORM (ST)

(493 SQ.FT.) CONNECT TO

DOWNSPOUT WITH BOOT

4" SUBSOIL DRAINAGE (SSD)

PIPE SEE STRUCTURAL PLANS

FOR INVERT ELEVATION

4" SUBSOIL DRAIN (SSD)

(I.E. = 850.50) SEE CIVIL

FOR CONTINUATION 4" STORM (ST)

(1246 SQ.FT) (I.E. = 850.00)

SEE CIVIL FOR CONTINUATION

4" STORM (ST)

(130 SQ.FT.) CONNECT TO

DOWNSPOUT WITH BOOT

4" STORM (ST)

(493 SQ.FT.) CONNECT TO

DOWNSPOUT WITH BOOT

4" STORM (ST)

(130 SQ.FT.) CONNECT TO

DOWNSPOUT WITH BOOT

4"SSD

4"SSD

4"SSD

4"ST

ABBREVIATIONS

STORM (ST)

SUBSOIL DRAIN

ELBOW DOWN

ELBOW UP

SYMBOLS

ST STORM SEWER

SSD SUBSOIL DRAIN

ST

SSD

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/2

/2

:2 :1

A

M C

U s e rs

\m js p e lle rb e rg

\D o c u m e n ts

\A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

P

P P h a s e

B m js p e lle rb e rg

.r v t

P-103

PLUMBING PLAN - COMMITTAL

SERVICE SHELTER 2

DJD BDB

PLUMBING PLAN - COMMITTAL

SERVICE SHELTER 2

COMMITTAL SERVICE SHELTER 2 - PLUMBING

SYMBOLS AND ABBREVIATIONS

A. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING FIXTURES SHALL BE OBTAINED FROM

THE ARCHITECTURAL REFLECTED CEILING PLAN.

B. LIGHTING FIXTURES WITH MORE THAN TWO LAMPS SHALL HAVE TWO OUTER LAMPS

CONTROLLED WITH ONE SWITCH AND INNER LAMP(S) CONTROLLED BY A SECOND SWITCH.

C. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE A SEPARATE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR.

D. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY AND NORMAL

BRANCH WIRING DEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.

E. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS PASSING THROUGH

RENOVATED AREAS AND SERVICING UNDISTURBED AREAS.

F. FOR EXACT LOCATION AND FINISH SURFACE CONDITIONS OF CEILING, WALL, FLOOR MOUNTED

DEVICES, REFER TO ARCHITECTURAL DRAWINGS.

G. FOR EXACT LOCATION OF FACILITY EXPANSION JOINTS, FIRE RATED WALLS AND SMOKE WALLS, REFER TO ARCHITECTURAL DRAWINGS.

H. FOR EXACT LOCATIONS OF DUCT MOUNTED SMOKE DETECTORS, REFER TO MECHANICAL DRAWINGS.

I. VERIFY EXACT LOCATION OF CONNECTION POINTS PRIOR TO CONNECTION.

J. MOUNTING HEIGHTS ARE TO CENTER OF DEVICE OR EQUIPMENT, UNLESS OTHERWISE NOTED.

K. PROVIDE RACEWAY, WIRE AND CABLE, ASSOCIATED FITTINGS AND CONNECTORS, AND COMPLETE

CONNECTIONS REQUIRED FOR DESIGNATED BRANCH CIRCUITS FROM DEVICE(S) TO FINAL

OVERCORRECT DEVICE AND TO LOCAL CONTROL DEVICE(S) PER SPECIFICATIONS.

L. MINIMUM BRANCH CIRCUIT WIRE SIZE SHALL BE #12 AWG EXCEPT LIFE SAFETY BRANCH CIRCUIT

WIRING WHICH SHALL BE MINIMUM #10 AWG. MAINTAIN MAXIMUM BRANCH CIRCUIT CONDUCTOR

LENGTHS AS PER SPECIFICATIONS AND SCHEDULED ON THIS DRAWING. INCLUDE GROUND

CONDUCTOR DERATINGS.

M. PULL A SEPARATE NEUTRAL CONDUCTOR FROM PANELBOARD FOR EACH SET OF INCANDESCENT

LUMINAIRES CONTROLLED FROM A DIMMER, EACH BRANCH CIRCUIT SERVING FLUORESCENT

LUMINAIRES, EACH BRANCH CIRCUIT SERVING NEMA 5 RECEPTACLES WITHIN SIX (6) FEET OF

COMPUTER DEVICE JACKS, AND EACH BRANCH CIRCUIT PROTECTED BY A GROUND FAULT CIRCUIT

INTERRUPTER. DERATE CONDUCTORS PER NEC ACCORDINGLY.

N. PROVIDE GROUNDING PER NEC. ALSO PROVIDE GREEN GROUND WIRE IN ALL BRANCH AND

FEEDER CIRCUITS SIZED PER NEC.

O. ALL STAIRWAY LIGHTING SHALL BE WIRED VERTICALLY.

P. NEW CIRCUIT BREAKERS ADDED IN EXISTING PANELS TO MATCH EXISTING BRANCH CIRCUIT INTERRUPT RATINGS.

SINGLE-PHASE

SINGLE POLE

TWO-CONDUCTOR

THREE-CONDUCTOR

THREE-PHASE

FOUR-CONDUCTOR

FOUR-WIRE

AIR CONDITIONING

ARCHITECT/ENGINEER

ALARM ANNUNCIATOR PANEL

AMPERE

ARMORED CABLE OR

ALTERNATING CURRENT

ACCESSIBLE

ADDITIONAL

ADJACENT, ADJOINING

AUTOMATIC DOOR OPENER

AMP FUSE

ABOVE FINISHED COUNTER OR

AUTOMATIC FREQUIENCY CONTROL

OR AVAILABLE FAULT CURRENT

ARC-FAULT CIRCUIT INTERRUPTING

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

AMPERE HOUR

AUTHORITY HAVING JURISDICTION

AIR HANDLING UNIT

AMPERE INTERRUPTING CAPACITY

ALUMINUM

ALTERNATE

AMMETER

AMBIENT

AMPERE

AMERICAN NATIONAL STANDARDS

INSTITUTE

ARCHITECT

AMPS SHORT CIRCUIT

AMPERE TRIP

AUTOMATIC TRANSFER SWITCH

AUTOMATIC

AUDIO VISUAL

AMERICAN WIRE GAUGE

BUILDING AUTOMATION SYSTEM

BATTERY

BARE COPPER

BOARD

BELOW FINISH FLOOR

BASIC INSULATION LEVEL

BUILDING

BOILER PLANT INSTRUMENTATION PANEL

BACKBOARD

BREAKER

CIRCUIT BREAKER

BY PASS

CONDUIT

CABINET

CALCULATE

CAPACITY

CATALOG

COMMUNITY ANTENNA TELEVISION

CONTROL CONTACTOR

CLOSED CIRCUIT TELEVISION

CANDELA

CONSTRUCTION DOCUMENTS

CONTRACTOR FURNISHED

CONTRACTOR FURNISHED. CONTRACTOR

INSTALLED

CONTRACTOR FURNISHED/

OWNER INSTALLED

CONTRACTOR FURNISHED EQUIPMENT

CHILLED WATER

CHILLED WATER PUMP

CIRCUIT

CIRCUIT BREAKER

CURRENT LIMITING FUSE

CEILING

CONSTRUCTION MANAGER

CONCRETE MASONRY UNIT

COMPANY

COAX CABLE

COMMUNICATION

COMPARTMENT

CONCRETE

CONTINUE

CONTRACTOR

COORDINATE

CONTROL POWER TRANSFORMER

COLOR RENDERING INDEX

CABLE TRAY OR CURRENT

TRANSFORMER

CLOSED TRANSITION TRANSFER SWITCH

CABLE TELEVISION

COPPER

CUBIC FEET

CURRENT

DIRECT CURRENT

DIMMER CONTROL PANEL

DEGREES CELSIUS

DEGREES FAHRENHEIT

DEMOLITION

DIAMETER

1PH

1P 2/C 3/C

3PH

4/C 4W

A/C UNIT

A/E

AAP

A

AC

ACC

ADDL

ADJ

ADO

AF

AFC

AFCI

AFF

AFG

AH

AHJ

AHU

AIC

AL

ALT

AM

AMB OR A

AMP

ANSI

ARCH

ASC

AT

ATS

AUTO

AV

AWG

BAS

BAT

BC

BD

BFF

BIL

BLDG

BPIP

BKBD

BRKR

BKR

BYP

C

CAB

CALC

CAP

CAT

CATV

CCR

CCTV

cd

CD

CF

CF/CI

CF/OI

CFE

CHW

CHWP

CKT

CKT BRKR OR

CB

CLF

CLG

CM

CMU

CO

COAX

COMM

COMPT

CONC

CONT

CONTR

COORD

CPT

CRI

CT

CTTS

CTV

CU

CU FT

CUR

DC

DCP

DEG C

DEG F

DEMO

DIA

INSIDE DIAMETER

ILLUMINATION ENGINEERING SOCIETY OF

NORTH AMERICA

INTERMEDIATE METAL CONDUIT

INCANDESCENT

INFRARED

INSTANT WATER HEATER

JUNCTION BOX

KILOVOLT

KILOVOLT AMPERE

KILOVOLT AMPERE PER HOUR

KILOVOLT AMPERE RACTIVE

KILOWATT

KILOWATT HOUR

LILOWATT HOUR METER

ID

IESNA

IMC

INCAND

IR

IWH

J-BOX

KV

KVA

KVAH

KVAR

KW

KWH

KWHM

DIVISION

DIAGRAM

DISCONNECT

DISTRIBUTION

DISTRIBUTION PANEL

DIMMER SWITCH

DOWN

DOUBLE POLE, DOUBLE THROW

DOUBLE POLE, SINGLE THROW

DOOR SWITCH

DISCONNECT SWITCH

DRAWING

EACH

EMPTY CONDUIT

EXHAUST FAN

EQUIPMENT GROUND

ENGINE-GENERATOR SET

ELEVATION

ELECTRIC OR ELECTRICAL

ELEVATOR

EMERGENCY MONITORING CONTROL

EMERGENCY

ELECTROMAGNETIC INTERFERENCE

ELECTRICAL EMTALLIC TUBING

ENCLOSURE

EQUIPMENT BY OWNER

EMERGENCY POWER OFF

EQUIPMENT

EASEMENT

EXISTING TO BE REMOVED

EXISTING TO REMAIN

ELECTRIC WATER COOLER

ELECTRIC WATER HEATER

EXHAUST

EXISTING

EXPLOSION PROOF

FIRE ALARM

FIRE ALARM ANNUNCIATOR PANEL

FIRE ALARM BELL

FIRE ALARM BOX

FIER ALARM CONTROL PANEL

FIRE ALARM CONTROL UNIT

FOOTCANDLE

FILM ILLUMINATOR

FIXTURE

FULL LOAD AMPS

FLEXIBLE METALLIC CONDUIT

FLOOR

FLOODLIGHT

FLUORESCENT

FUORERSCENT FIXTURE

TELEPHONE FLOOR OUTLET

FIRE PROTECTION

FIELD PROCESSING UNIT

FEET OR FOOT

FEED THRU LUGS

FUSED SWITCH

FULL VOLTAGE NON-REVERSING

FULL VOLTAGE REVERSING

GENERATOR

GROUND OR GENERATOR

GAUGE

GROUNDING EQUIALIZER CONDUCTOR

GENERATOR

GROUND FAULT CIRCUIT INERRUPTER

GROUND FAULT INTERRUPTING

GROUND TERMINAL BOX

HARMONIC CONDITIONING TRANSFORMER

HARMONIC FILTER

HARMONIC FILTER WITH INTEGRAL

TRANSFORMER

HIGH INTENSITY DISCHARGE

HAND-OFF-AUTOMATIC

HORSEPOWER

HARMONIC SUPPRESSION TRANSFORMER

HOUSEKEEPING

HEIGHT

HEATER

HERTZ

DIV

DIAG

DISC

DISTR

DISTR PNL

DMR SW

DN

DPDT

DPST

DRSW

DS

DWG

EA

EC

EF

EG

EGS

EL

ELEC

ELEV

EMCP

EMER

EMI

EMT

ENCL

EO

EPO

EQUIP

ESMT

ETBR

ETR

EWC

EWH

EXH

EXIST

EPRF

FA

FAAP

FABL

FABX

FACP

FACU

FC

FI

FIXT

FLA

FLEX

FLR

FLT

FLUOR

FLUOR FIX

FOUTT

FP

FPU

FT

FTL

FU SW

FVNR

FVR

G

G OR GND

GA

GE

GEN

GFCI

GFI

GTB

HC

HF

HFT

HID

HOA

HP

HS

HSKPG

HT

HTR

HZ

LIGHTNING ARRESTOR

LIGHT EMITTING DIODE

LINEAR FEET

LUMEN

LIGHT POLE

LOW PRESSURE SODIUM

LOCKED ROTOR AMPS

LIFE SAFETY

LIGHT

LOCAL TEMPERATURE CONTROL PANEL

LONG TIME DELAY

LIGHTING

LIGHTING PANEL

LIGHTNING

LOW VOLTAGE

MAXIMUM

MASTER ANTENNA TELEVISION SYSTEM

METAL-CLAD

MINIMUM CIRCUIT AMPS

MAIN CIRCUIT BREAKER

MOTOR CONTROL CENTER

MOTOR CIRCUIT PROTECTOR

MAIN DISTRIBUITION PANEL

MECHANICAL

MAIN FUSED SWITCH

MOTOR GENERATOR

MEDICAL GAS PANEL

MANHOLE

MINERAL INSULATED CABLE

MINIMUM

MAIN LUGS ONLY

MAXIMUM OVERCURRENT PROTECTION

MOUNT

MOUNTED

MOUNTING

MANUAL TRANSFER SWITCH

MEDIUM VOLTAGE

MEGAVOLT-AMPERE

MEGAWATT MICROWAVE

NOT APPLICABLE

NORMALLY CLOSED

NATIONAL ELECTRICAL CODE

NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NEUTRAL

NATIONAL FIRE PROTECTION ASSOCIATION

NOT IN CONTRACT

NIGHT LIGHT

NORMALLY OPEN

NETWORK OPERATIONS CENTER

NO SCALE

NOT TO SCALE

OUTSIDE AIR

ON CENTER

OVERCURRENT PROTECTIVE DEVICE

OUTSIDE DIAMETER

OVERHEAD

OVERLOAD

POLE

PUBLIC ADDRESS

PANELBOARD

PREFABRICATED BEDSIDE PATIENT UNIT

POLYCHORINATED BIPHENYL

PNEUMATIC - ELECTRIC

PHOTOELECTRIC CELL

PEDESTAL

PENDANT

POWER FACTOR

PHASE

PROGRAMMABLE LOGIC CONTROL

PANELBOARD

POWER OPERATED DAMPER

PATIENT SERVING UNIT

POTENTIAL TRANSFORMER

POWER TYPE ROOF VENTILATION

PAN/TILT/ZOOM

POLYVINYL CHLORIDE (PLASTIC)

POWER

REFLECTED CEILING PLAN

REFER TO

RECESSED

RECEPTACLE

REFRIGERATOR

REQURED

RETURN FAN

RIGID GALVANIZED STEEL

ROOM

ROOT MEAN SQUARE

ROTARY HYBRID UNINTERUPTIBLE

POWER SUPPLY

SHORT CIRCUIT CAPACITY

SCHEDULE

SMOKE DETECTOR

SERVICE ENTRANCE SECTION

OR SQUARE FOOT (FEET)

SUB FEED LUGS

SURGICAL FACILITY PANEL

SHEET

INTERNATIONAL SYSTEM OF UNITS

SPACE

SPECIFICATION

SPARE

SINGLE PLE, SINGLE THROW

STAINLESS STEEL

SHORT TIME DELAY

SHIELDED TWISTED PAIR

STARTER

SURFACE

SWITCH

SITCHBOARD

SWITCHGEAR

TELECOMMUNICATIONS BONDING BACKBONE

TIME CLOCK

TERMINAL

TELEPHONE

TELECOMMUNICATONS GROUNDING BUS BAR

TOTAL HARMONIC DISTORTION

TELECOMMUNICATIONS MAIN GROUNDING

BUS BAR

TWISTED PAIR

TWISTED PAIR SHIELDED

TELECOMMUNICATIONS ROOM

TRANSITION

TRANSFORMER

TELECOMMUNICATIONS SERVICE

ENTRANCE ROOM

TELEPHONE TERMINAL BOARD

TELEVISION

TRANSIENT VOLTAGE SURGE SUPPRESSION

TYPICAL

UNDERCOUNTER

UNDERFLOOR DUCT

UNDERGROUND

UNDERWRITERS LABORATORY

UNLESS OTHERWISE NOTED

UNINTERRPTIBLE POWER SUPPLY

UNIT SUBSTATION

UTILITY

UNSHIELDED TWISTED PAIR

VOLT

VOLT AMPERE

VOLT AMPERE REACTIVE

VARIABLE FREQUIENCY DRIVE

VOLTMETER

VARIABLE SPEED DRIVE

WATT

WATER HEATER

WEATHERPROOF

TRANSFER

TRANSFORMER

LA

LED

LF

LM

LP

LPS

LRA

LS

LT

LTCP

LTD

LTG

LTG PNL

LTNG

LV

MAX

MATV

MC

MCA

MCB

MCC

MCP

MDP

MECH

MFS

MG

MGP

MH

MI

MIN

MLO

MOCP

MT

MTD

MTG

MTS

MV

MVA

MW

NA

NC

NEC

NEMA

NEUT OR N

NFPA

NIC

NL

NO

NOC

NS

NTS

OA

OC

OCPD

OD

OH

OL

P

PA

PB

PBPU

PCB

P/E

PEC

PED

PEND

PF

PH/*

PLC

PNL

POD

PSU

PT

PTRV

PTZ

PVC

PWR

RCP

RE

REC

RECPT

REF

REQD

RF

RGS

RM

RMS

RUPS

SCC

SCHED

SD

SES

SF

SFL

SFP

SHT

SI

SPC

SPEC

SPR

SPST

SS

STD

STP

STR

SURF

SW

SWBD

SWGR

TBB

TC

TERM

TEL

TGB

THD

TMGB

TP

TPS

TR

TRAN

TRANSF

TSER

TTB

TV

TVSS

TYP

UC

UFD

UGND

UL

UON

UPS

USS

UTIL

UTP

V

VA

VAR

VFD

VM

VSD

W

WH

WP

XFER

XFMR

II ROMAN NUMERAL INDICATES QUANTITY OF GANGED DEVICES

UNDER COMMON FACEPLATE.

a LOWER CASE LETTER INDICATES DEVICE CONTROL ARRANGEMENT

7 NUMERAL INDICATES BRANCH CIRCUIT NUMBER

A WITH AUXILIARY CONTACTS

B REMOVE DEVICE AND INSTALL BLANK COVERPLATE

BF BLANK FACE GFCI

BS ITEM CONTROLLED BY BED STOP RELAY

C ITEM INSTALLED FLUSH IN CEILING

C* CONTROL POINT IDENTIFIER (* INDICATES CONTROL NUMBER)

D 120 VOLT DISCONNECT SWITCH ARRANGEMENT

E EXISTING BACKBOX TO REMAIN AND BE REUSED

EO EQUIPMENT SUPPLIED BY OWNER

EQ ITEM INSTALLED IN EQUIPMENT

FL ITEM INSTALLED FLUSH IN FLOOR

GFCI GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLE

GFI GROUND FAULT CIRCUIT INTERRUPTING BREAKER PROTECTED

GFP FEED THROUGH GROUND FAULT CIRCUIT INTERRUPTING PROTECTED

H HORIZONTALLY MOUNTED

HA HIGH ABUSE COVERPLATE

HG HOSPITAL GRADE

IG ISOLATED GROUND RECEPTACLE

K KEY OPERATED

L LOW VOLTAGE

M MULLION MOUNTED

M* MONITORING POINT IDENTIFIER (* INDICATES MONITORING POINT)

NL NIGHT LIGHT RECEPTACLE

NLG NIGHT LIGHT GFCI RECEPTACLE

P PILOT LAMP SWITCH

PP FOR AUTO DOOR PUSH PLATE

S SURFACE MOUNTED

SG SAFETY GROUNDING RECEPTACLE

SP SURGE PROTECTOR RECEPTACLE

SW SPLIT WIRED RECEPTACLE FOR REMOTE SWITCHING

TR TAMPER RESISTANT

W ITEM INSTALLED 44" A.F.F. OR AS DETAILED

WG WIRE GUARD

WP WEATHERPROOF

WPS WEATHERPROOF SPRING COVER

Z* DEVICE ZONE IDENTIFIER (* INDICATES ZONE NUMBER)

MTS MANUAL TRANSFER SWITCH-STANDBY

ATSF AUTOMATIC TRANSFER SWITCH-FIRE PUMP

BPS BOLTED PRESSURE SWITCH

IDRS INTEGRATED DATA CENTER RACK SYSTEM

IEC INTERCOM EQUIPMENT CABINET

LVC LOW VOLTAGE LIGHTING CABINET

LVS LOW VOLTAGE POWER SWITCHGEAR

MCCN MOTOR CONTROL CENTER-NORMAL

MVS MEDIUM VOLTAGE SWITCHGEAR

PBL PLUG-IN BUSWAY LIGHTING

PBP PLUG-IN BUSWAY POWER

PSWGR PARALLELING SWITCHGEAR

TBTP TELECOMMUNICATION BACKBONE TERMINATION PANEL

TDTP TELECOMMUNICATION DEVICE TERMINATION PANEL

TC TIMECLOCK

TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR

UPS UNINTERRUPTIBLE POWER SUPPLY

USSHV UNIT SUBSTATION AT 480Y/277 SECONDARY VOLTAGE

USSLV UNIT SUBSTATION AT 208Y/120 SECONDARY VOLTAGE

D "D" BUILDING (SEE SITE PLAN FOR DESIGNATIONS)

FLOOR

EQUIPMENT NAME

SEQUENCE NUMBER

NUMBERS IN SEQUENCE - 1,2,3,ETC.

CB CIRCUIT BREAKER

CRT FIRE ALARM CRT ANNUNCIATOR

DS UNFUSED DISCONNECT SWITCH

DT DAY TANK

EC ELEVATOR CONTACTOR

FAP FIRE ALARM ANNUNCIATOR

FATC FIRE ALARM TERMINAL CABINET

FDS FUSED DISCONNECT SWITCH

GC GENERAL PURPOSE CONTACTOR

LC LIGHTING CONTACTOR

MMC MODULAR METER CENTER

MS METER SOCKET

RUPS ROTARY HYBRID UNINTERRUPTIBLE POWER SUPPLY

SWBDN SWITCHBOARD-NORMAL

T TRANSFORMER

TMGR TELECOMMUNICATION MAIN GROUND BUS

TMGB TELECOMMUNICATION ROOM GROUND BUS

B BASEMENT

G M GROUND

1 FIRST FLOOR

2 SECOND FLOOR

M MEZZANINE

BUILDING

ATSS AUTOMATIC TRANSFER SWITCH-LIFE SAFETY (NEC 517)

ATSC AUTOMATIC TRANSFER SWITCH-CRITICAL (NEC 517)

ATSE AUTOMATIC TRANSFER SWITCH-EQUIPMENT (NEC 517)

FPU FIELD PROCESSING UNIT

MCCE MOTOR CONTROL CENTER-EQUIPMENT (NEC 517)

NEC NURSE CALL EQUIPMENT CABINET

SWBDS SWITCHBOARD-LIFE SAFETY (NEC 517)

SWBDC SWITCHBOARD-CRITICAL (NEC 517)

SWBDE SWITCHBOARD-EQUIPMENT (NEC 517)

MAXIMUM CONDUCTOR LENGTH AT 120V 95 160 245

NOTES:

1. INCREASE BRANCH CIRCUIT CONDUCTOR AS INDICATED.

2. BASED ON 20 AMP CIRCUIT LOADED TO 10 AMP USING SINGLE PHASE,

2 WIRE CIRCUITS.

3. SCHEDULE REPRESENTS MINIMUM CONDUCTOR SIZE BASED ON

LENGTH OF BRANCH CIRCUIT CONDUCTOR FROM PANEL TO PHYSICAL

CENTER OF LOAD TO OVERCOME VOLTAGE DROP. 3% VOLTAGE

DROP ASSUMED.

4. TRANSITION FROM LARGER CONDUCTOR SIZE TO #12 FOR FINAL

TERMINATION TO OUTLET DEVICE. PROVIDE JUNCTION BOX WITHIN 10'

OF OUTLET. EXTEND #12 CONDUCTOR TO OUTLET.

GROUND CONDUCTOR AWG #12 #10 #10

MAXIMUM CONDUCTOR LENGTH AT 480V 1 PH. 390 650 985

MAXIMUM CONDUCTOR LENGTH AT 208V 1 PH. 170 280 425

MAXIMUM CONDUCTOR LENGTH AT 277V 225 375 565

CONDUCTOR AWG #12 #10 #8

DB RIGID CONDUIT LINE = RC , DIRECT BURIAL CABLE = DB, POWER DUCT = P

MANHOLE

HANDHOLE

TRANSFORMER MANHOLE OR VAULT

TELECOMMUNICATIONS MANHOLE

DUAL POWER AND TELECOMMUNICATIONS MANHOLE

SUBSTATION

UNDERGROUND CONSTRUCTION

M

H

TM

S

P T

C

LIGHTING BRANCH CIRCUITS

FA1 LUMINAIRE TYPE

3 CIRCUIT NUMBER (AND PANELBOARD IF SPECIFICALLY DESIGNATED)

a CONTROL ARRANGEMENT

BOXES AND CABINETS

JUNCTION BOX

PULL BOX

CABINET, TOP OF TRIM 6'-2" AFF

DIRECT CONNECTION OR MATCHING RECEPTACLE FOR 120 VOLT EQUIPMENT

DIRECT CONNECTION OR MATCHING RECEPTACLE FOR 240 VOLT EQUIPMENT

DIRECT CONNECTION TO UNDERCOUNTER LUMINAIRE. WIRE UNITS IN PARALLEL

DIRECT CONNECTION TO 120 VOLT SINK AND URINAL SOLENOID

DIRECT CONNECTION TO 120 VOLT SMOKE DAMPER SOLENOID

CABINET UNIT HEATER

UNIT HEATER

MOTOR, SINGLE-PHASE

MOTOR, THREE-PHASE

WIRING TERMINATIONS

NEC GROUND CONDUCTOR

GROUND ROD WITH WELDED TERMINATION

MECHANICAL CONNECTION

MOLDED FUSION WELD

EQUIPMENT ROOM GROUND BAR OF LENGTH INDICATED, 18" AFF

TELECOM MAIN GROUND BUS, 18" AFF

TELECOM GROUND BUS, 18" AFF

EARTH GROUND

GROUNDING AND BONDING

RACEWAYS AND PATHWAYS

CONDUIT TERMINATED 6" [152] AFF IN STANDARD BOX FOR EXTENSION TO

EQUIPMENT AS DIRECTED

CONDUIT TERMINATED W/COUPLING (FLUSH W/FINISHED FLOOR) FOR

EXTENSION TO EQUIPMENT AS DIRECTED

CONDUIT TURNED DOWN

CAPPED CONDUIT

CONDUIT STUBBED AND BUSHED INTO ACCESSIBLE CEILING CAVITY

SERVICE WEATHERHEAD

GENERAL

NEW EQUIPMENT

EXISTING EQUIPMENT

DEVICE TO BE REMOVED (DEMO PLANS) UNDERFLOOR CONDUIT (NEW PLANS)

WIRE AND/OR CONDUIT RUN CONTINUED ON REFERENCED DETAIL

MATCH LINE REFERENCING CONTINUATION ON OTHER DRAWING

DETAIL AND/OR SECTION REFERENCE

BRANCH CIRCUIT BOUNDARY

POWER BRANCH CIRCUITS

23 CIRCUIT NUMBER (AND PANELBOARD IF SPECIFICALLY DESIGNATED)

DRAWING NOTES AND DESIGNATIONS

DRAWING KEYED NOTES

BRANCH CIRCUITING NOTES

EQUIPMENT DESIGNATIONS

FEEDER NUMBER

DETAIL OR SECTION REFERENCE TAG

LAB EQUIPMENT TAG

X

X X

X X

J

CH

UH

GROUND

TMGB

TGB

X

X

X

FA1

3a

PB

G

TRANSFORMERS

TRANSFORMER, PLAN

TRANSFORMER (SINGLE-LINE DENOTATION)

HARMONIC FILTER

3-PHASE WYE, NEUTRAL UNGROUNDED CONNECTION

3-PHASE, 3-WIRE DELTA CONNECTION

WYE CONNECTION

DISTRIBUTION PANEL

PANELBOARD CABINET, FLUSH MOUNTED

PANELBOARD CABINET, SURFACE MOUNTED

PANELBOARDS

CONTACTORS

GENERAL PURPOSE CONTACTOR, 5'-0" AFF

LIGHTING CONTACTOR, 5'-0" AFF

HF

GC

LC

T

DP

F = FUSED SWITCH

L = LOCK

M = MANUAL MOTOR STARTING

MP = MOTOR SNAP WITH PILOT LIGHT

(THERMAL TYPE)

PB = PUSH BUTTON STATION

WP = WEATHER PROOF

K = KEY OPERATED

LM = LOW VOLTAGE MASTER

MC = MOMENTARY CONTACT

P = WITH PILOT LIGHT

RC = REMOTE CONTROL

X = EXPLOSION PROOF

SWITCH

DISCONNECT SWITCH, UNFUSED

DISCONNECT SWITCH, FUSED

SEPARATELY ENCLOSED CIRCUIT BREAKER, FLUSH MOUNTED 44" AFF

(# INDICATES TRIP RATING)

PROTECTIVE DEVICES

MOLDED CASE CIRCUIT BREAKER

FUSE WITH RATING

FUSIBLE LINK

MOTOR CONTROLLERS

SWITCH, MANUAL MOTOR STARTING

STARTER, COMBINATION WITH DISCONNECT SWITCH

VARIABLE SPEED DRIVE

VARIABLE FREQUENCY DRIVE

STARTER OR MOTOR CONTROLLER

T

VFD

CB 30

VSD

WIDE VIEW OCCUPANCY SENSOR, 7'-6" AFF OR CEILING MOUNTED,

ARROW INDICATES DIRECTION

360° OCCUPANCY SENSOR, CEILING MOUNTED

NARROW VIEW OCCUPANCY SENSOR, 7'-6" AFF OR CEILING MOUNTED,

ARROW INDICATES DIRECTION

ELECTRONIC TIME SWITCH, 4'-6" AFF

EXTERIOR PHOTOCELL, 1'-0" ABOVE ROOF, AIMED NORTH

AUTOMATIC LIGHTING CONTROL EQUIPMENT

P1

P2

P3

TC

PC

RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER

NEMA 5-20R GFCI RECPTACLE, 18" AFF

NEMA 5-20R GFCI DUPLEX REC. IN WP BOX WITH WP COVER, 18" A.G.

RECEPTACLE, DUPLEX SWITCHED

RECEPTACLE, DUPLEX SWITCHED WITH GROUND FAULT CIRCUIT

INTERRUPTER

INDICATES DEVICES MOUNTED UNDER COMMON COVERPLATE AT

LEG LOCATION

SWITCH, 44" A.F.F.

BLANK = SINGLE POLE 2 = DOUBLE POLE

3 = THREE-WAY 4 = FOUR-WAY

D = DIMMER K = KEY OPERATED

L = LOCK LV = LOW VOLTAGE

Mo = OCCUPANCY SENSOR P = WITH PILOT LIGHT

T = ELECTRONIC TIMER

RECEPTACLE, SINGLE

RECEPTACLE, DUPLEX

RECEPTACLE, QUADRAPLEX

RECEPTACLE, SINGLE WITH SWITCH

DROP CORD, SINGLE CONVENIENCE OUTLET, 3-WIRE, GROUNDING TYPE, 20A,

W/#12 CONDUCTORS IN FLEXIBLE CORD (CENTER LINE OF OUTLET: 6'-6"

(1981mm AFF. MINIMUM)

FLOOR OUTLET, DATA COMMUNICATION

3-GANG COMPARTMENT BOX IN FLOOR FOR TELEPHONE, DATA &

RECEPTACLE

WIRING DEVICES

DEVICE BOX WITH BLANK COVERPLATE, 18" AFF

S

S

S

G1

W

B

RECEPTACLE, SPECIAL PURPOSE

A = 120V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 5-20R

B = 208V, 20A, 1 PHASE, 2-POLE, 3W, NEMA 6-20R

C = 120V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 5-30R

D = 208V, 30A, 1 PHASE, 2-POLE, 3W, NEMA 6-30R

E = 208V, 60A, 1 PHASE, 3-POLE, 4W, NEMA 14-60R

F = 208V, 30A, 3 PHASE, 3-POLE, 4W, NEMA 15-30R

G = 208V, 50A, 3 PHASE, 3-POLE, 4W, NEMA 15-30R

H = 208V, 60A, 3 PHASE, 3-POLE, 4W, NEMA 15-60R

GENERATOR, POWER

TRANSFER SWITCH

ISOLATION BYPASS TRANSFER SWITCH

CLOSED TRANSITION TRANSFER SWITCH

EGS ALARM ANNUNCIATOR, TOP OF TRIM 4'-6" AFF

EMERGENCY POWER GENERATION

EAA

G

LIGHT FIXTURE WALL MOUNTED

LIGHTING, TWO HEAD EMERGENCY BATTERY POWER

LIGHTING, EXTERIOR BUILDING

INTERIOR AND EXTERIOR LIGHTING

LIGHT FIXTURE, STRIP/INDUSTRIAL ;

LETTER INDICATES TYPE (TYPICAL FOR ALL)

LUMINAIRE

LIGHT FIXTURE, RECESSED , 2'x4' [610x1220mm];

LIGHT FIXTURE, RECESSED , 1'x4' [305x1220mm];

LIGHT FIXTURE, RECESSED , 1'x8' [305x2439mm];

LIGHT FIXTURE, RECESSED , 2'x2' [610x610mm];

LIGHT FIXTURE, SURFACE MOUNTED , 2'x4' [610x1220mm];

LIGHT FIXTURE, SURFACE MOUNTED , 2'x4' [610x1220mm];

LIGHT FIXTURE, SURFACE MOUNTED , 1'x8' [305x2439mm];

LIGHT FIXTURE, SURFACE MOUNTED , 2'x2' [610x610mm];

LIGHT FIXTURE CEILING MOUNTED

EXIT SIGN, WALL MOUNTED. DIRECTIONAL ARROWS AND/OR LINES

INDICATE LOCATION OF FACE AND DIRECTION OF EXIT

EXIT SIGN, CEILING MOUNTED. DIRECTIONAL ARROWS AND/OR LINES

INDICATE LOCATION OF FACE AND DIRECTION OF EXIT

PARALLEL CONNECTED SPD, TOP OF ENCLOSURE 6'-2" AFF

SERVICE ENTRANCE SPD

A

B

C

A

B

C

E

E

SPD

S

EGS EMERGENCY POWER OFF SWITCH, CENTER OF SWITCH 4'-6" AFFEPO

360° HIGH BAY OCCUPANCY SENSOR, CEILING MOUNTEDP7

TIMER WALL SWITCHT

DIMMER SWITCHL

DAYLIGHT HARVESTING SENSORDH

MOUNTING HEIGHT ABOVE FINISHED FLOOR, COORDINATE WITH

ARCHITECURAL ELEVATIONS

+XX"

DIRECT CONNECTION TO 480 VOLT EQUIPMENT3

SWITCH BOX MOUNTED OCCUPANCY SENSORP

LUMINAIRE WITH INTEGRAL EMERGENCY BATTERY

(INDICATED BY DARK SHADING)

WALL MOUNTED OCCUPANCY SENSOR SWITCHP4

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/1

/2

:3

:0

A

M C

U s e rs

\b jh o ff m a n n \D o c u m e n ts

\A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

E

E P h a s e

B b jh o ff m a n n .r v t

E-001

ELECTRICAL SYMBOLS &

ABBREVIATIONS

SMW BSM

ELECTRICAL SYMBOLS &

ABBREVIATIONS

ELECTRICAL GENERAL NOTES

ELECTRICAL ABBREVIATIONS

ELECT. ABBREVIATIONS (CONT.)

DEVICE SUBSCRIPTS

EQUIPMENT DESIGNATION

BRANCH CIRCUIT VOLTAGE DROP

DIVISION 26 LEGEND

bjhoffmann Snapshot

A

B

T

P

M

ST

ST

GLM

H

H

H

H

H

H

H

H

H

H

H

12"LINE SIDES OF

EXCAVATION WITH

(30 LBS.) FELT

PAPER

V A

R

IE

S

GRADE. FEATHER & TAMP

BACKFILL TO CREATE FLUSH

INSTALLATION AND POSITIVE

DRAINAGE AWAY FROM BOX

CLEAN (3/4")

CRUSHED ROCK

CONDUIT(S) WITH BELL

ENDS (TYP). SIZE,

QUANTITY AND WIRING

AS INDICATED ON PLANS

(4) CONCRETE

BRICKS (2"x8"x16")

SOLID BOTTOM PULLBOX

(SEE SPECIFICATIONS)

NOTES:

1. SEAL CONDUIT ENDS WITH WATER TIGHT SEALANT AFTER CONDUCTORS ARE INSTALLED

TO MINIMIZE WATER INFILTRATION IN THE CONDUIT SYSTEM.

2. SEAL ALL CONDUIT PENETRATIONS INTO HANDHOLE.

SOLID BOTTOM HANDHOLE SHALL BE SIZED FOR "U-

PULL" TYPE CONDUIT ENTRY UTILIZING 4"C ON SAME

SIDE. PROVIDE A 36"L X 24W X 30H HANDHOLE OR AS

REQUIRED PER CONTRACTOR CALCULATION BASED

ON DIFFERENT CONDUIT DIMENSION INSTALLATION.

24"

INDIAN FALLS ROAD

A L L E

G H

A N

Y R

O A

D

INCOMING SERVICE

FROM NATIONAL GRID

13,200V

ADMIN

BUILDING

BID OPTION 6

(INSTALL CEMETERY

I.D. FEATURES...) (5)

LX6, 4'-0" OC,

A/P-HDP-4

K

K

K FOR THIS SECTION OF CIRCUIT

BETWEEN HANDHOLES, UTILIZE

EXISTING BURIED 1 1/2" CONDUIT

DIRECTIONAL BORE UNDER

EXISTING PAVEMENT

CONDUIT LEGEND (SEE DETAIL B6/ES102)

G 2”C – 4#4,#8G (COMMITAL SHELTER #2) BID OPTION 2

G1 EXISTING 2"C - NEW 4#4,#8G (COMMITAL SHELTER #2) BID OPTION 2

K 1"C - DIRECT BURY, 2#10,#10G (I.D. FEATURE LIGHTING NORTH) BID OPTION 6

L 2”C – (SPARE) BID OPTION 2

X

SYMBOL LEGEND

H EXISTING HANDHOLE

EXISTING DUCTBANK

NEW DUCTBANK OR

EXISTING DUCTBANK WITH

NEW CONDUCTORS (SEE

CONDUIT LEGEND)

X

H NEW HANDHOLE*

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/2

/2

:3 :2

P

M C

U s e rs

\b jh o ff m a n n \D o c u m e n ts

\A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

E

E P h a s e

B b jh o ff m a n n .r v t

ES101

ELECTRICAL SITE PLAN AREA A

SMW BSM

ELECTRICAL SITE PLAN AREA A

0 60' 120' F8

KEYPLAN AREA A

F1

HANDHOLE DETAIL

1" = 60'-0" F2

ELECTRICAL SITE PLAN - AREA A

1. ROUTE CONDUIT UP FACE OF BUILDING APPROXIMATELY 36" ABOVE FINISHED GRADE

AND THEN INTO EXISTING ELECTRICAL ROOM. ROUTE TO EXISTING PANEL A/P-HDP,

CIRCUIT NO. 4 (EXISTING PARKING LOT LIGHTING CIRCUIT) THRU LOAD SIDE OF EXISTING

EXTERIOR LIGHTING CONTACTOR.

KEYED NOTES :

B

D

H

H

H

H

H

H

H

H

H

H

H

IRRIGATION

BOOSTER PUMP IRRIGATION

CONTROLLERS

HONOR

GUARD

COMMITTAL

SHELTER 1

FUTURE

CENTERLINE OF

DUCTBANK TO BE

INSTALLED 5' FROM

BACK OF CURB

G1 G1

COMMITTAL

SHELTER 2

G

G

L

L

G L

CONDUIT LEGEND (SEE DETAIL B6/ES102)

G 2”C – 4#4,#8G (COMMITAL SHELTER #2) BID OPTION 2

G1 EXISTING 2"C - NEW 4#4,#8G (COMMITAL SHELTER #2) BID OPTION 2

K 1"C - DIRECT BURY, 2#10,#10G (I.D. FEATURE LIGHTING NORTH) BID OPTION 6

L 2”C – (SPARE) BID OPTION 2

X

PLASTIC SPACER

INNERDUCT,

SEE NOTE 5

DUCT (SIZE AS

INDICATED ON DWGS)

6-WAY DUCT LINE 4-WAY DUCT LINE

2-WAY DUCT LINE

TIE WIRE

(3")

(3")

76mm

3" m m

3" m m

76mm

(3")

76mm

3" m m

3" m m

(3 m m

(3")

(3")

76mm

(3")

76mm76mm

(3

3" m m m m m m

3"

76mm

(3")

76mm

(3")

(3")

76mm

152mm

(6")(SEE NOTE 4)

(T Y

P

GENERAL NOTES:

1. CONCRETE SHALL BE 4000PSI @ 28 DAYS, OR AS SPECIFIED.

2. PROVIDE #4 REINFORCING RODS ON TOP AND BOTTOM OF

DUCTS WHEN CROSSING OR PLACED IN ROADWAYS.

3. MINIMUM COVER TO TOP OF ENVELOPE SHALL BE 610MM (48") OR AS

OTHERWISE SPECIFIED IN SECTION 26 05 41.

4. PROVIDE MINIMUM 152MM (6") SPACE BETWEEN POWER AND

TELECOMMUNICATIONS/LOW VOLTAGE DUCTS. INCREASE SIZE

AS REQUIRED.

5. INNERDUCT QUANTITY AND SIZE AS INDICATED ON PLANS.

6. INCLUDE NYLON PULL ROPE IN ALL EMPTY DUCTS.

7. DUCT CONFIGURATIONS SHOWN ARE TYPICAL AND ARE SHOWN

TO INDICATE REQUIRED, MATERIALS, SPACING, ETC. INSTALL DUCT

CONFIGURATION AS REQUIRED TO REFLECT CONDUIT AMOUNTS

SHOWN ON PLANS.

SYMBOL LEGEND

H EXISTING HANDHOLE

EXISTING DUCTBANK

NEW DUCTBANK OR

EXISTING DUCTBANK WITH

NEW CONDUCTORS (SEE

CONDUIT LEGEND)

X

H NEW HANDHOLE*

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/1

/2

:3

:2

A

M C

U s e rs

\b jh o ff m a n n \D o c u m e n ts

\A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

E

E P h a s e

B b jh o ff m a n n .r v t

ES102

ELECTRICAL SITE PLAN AREA B

SMW BSM

ELECTRICAL SITE PLAN AREA B

0 60' 120' F8

KEYPLAN AREA B

1" = 60'-0" F2

ELECTRICAL SITE PLAN - AREA B

NTS

B6

DUCTBANK DETAILS

5.B 1.B 2B

A.B

D.B

B.B

C.B

1.2B 1.5B

1.4B

1.3B

CLOSET

B-101

SHELTER

B-100

LI1

WP

CS2

2 b

LX3

2 b

LX3

2 b

LX3

2 a

LG1B

2 a

LG1B

2 a

LG1B

2 b

LX3

2 b

LX3

a b

2 b

LX3

P4

LUMINAIRE SCHEDULE

LX3 22" TALL

EXTERIOR

DECORATIVE

VERTICAL LED

SCONCE

SURFACE,

WALL,

BOTTOM OF

FIXTURE AT 6'-9"

AFF

1419 LM N/A INTEGRAL UNIV 21.5 95 LM/W OPAL TOP AND BOTTOM LENS FINISH TBS, UL LISTED FOR WET

LOCATIONS, 2 VERTICAL BAR TRIM

AND 1 HORIZONTAL BAR TRIM

STYLE, EXTREME COLD WEATHER

COMPLIANT

LED LED

PACKAGE DRIVER

3000K CCT

MIN 80 CRI

GENERAL NOTES:

A REFERENCED PRODUCTS ARE INCLUDED HEREIN, OF MANUFACTURERS & PRODUCTS, THAT GENERALLY CONFORM TO THE LUMINAIRE DESIGN INTENTS ESTABLISHED HEREIN, & IN THE PROJECT MANUAL. EQUIVALENT

PRODUCTS BY OTHER MANUFACTURERS MAY BE CONSIDERED, PRIOR TO BID.

B DETERMINE SPECIFIC LUMINAIRE PART NUMBERS BASED ON THE REFERENCED PRODUCT SERIES, WRITTEN DESCRIPTIONS & PROJECT MANUAL SPECIFICATIONS.

C INCLUSION HEREIN OF MANUFACTURER'S SERIES &/OR MODEL NUMBERS DOES NOT IMPLY UNCONDITIONAL PRODUCT APPROVAL - MANUFACTURER'S STANDARD PRODUCTS MAY REQUIRE CUSTOM MODIFICATIONS

TO MEET THE REQUIREMENTS SPECIFIED HEREIN & IN THE PROJECT MANUAL.

D LISTED SIZES, LAMPING, & TYPES OF LUMINAIRES MAY NOT BE STANDARD PRODUCTS PRODUCED FROM ANY GIVEN MANUFACTURER OR SERIES LISTED. MANUFACTURER'S STANDARD PRODUCTS MAY REQUIRE CUSTOM

MODIFICATIONS TO MEET THE DESIGN CRITERIA, DESCRIPTIONS, & REQUIREMENTS SPECIFIED HEREIN & IN THE PROJECT MANUAL.

E ALERT ARCHITECT TO DISCREPANCIES PRIOR TO BID.

ABBREVIATIONS:

CONC CONCRETE EXP EXPOSED NT NARROW TEE GRID SPEC SPECULAR WH WHITE

DW DRYWALL LG LAY-IN GRID PAF PAINT AFTER FABRICATION S'SPEC SEMI-SPECULAR

D/I DIRECT/INDIRECT LM DELIVERED LUMENS PARA PARABOLIC SS STAINLESS STEEL

EFF EFFICIENCY/EFFICACY/LM/W LM/FT LUMENS PER LINEAR FOOT PPC POLYESTER POWDER COAT FINISH TBS TO BE SELECTED BY ARCH/INT DESIGNER

ELBD EMERG. LTG. BYPASS DEVICE LM/W LUMENS PER WATT REFL'T REFLECTOR/REFLECTANCE UNIV UNIVERSAL 120-277 VAC

NOTES:

1 COORDINATE MOUNTING/FLANGE CONDITION WITH REFLECTED CEILING PLAN/ARCHITECT PRIOR TO ORDERING AND INSTALLATION.

2 UNLESS OTHERWISE NOTED, BOTTOM OF LUMINAIRE TO BE AT 8'-0" A.F.F.

3 PROVIDE DRIVERS/BALLASTS AND CONTROLS TO ACCOMMODATE SWITCHING/CONTROL AS INDICATED ON DRAWINGS.

4 REFER TO ARCHITECTURAL CEILING PLANS/DETAILS FOR ADDITIONAL INFORMATION. FINAL DETAILS TO BE VERIFIED PRIOR TO CONSTRUCTION.

5 LUMINAIRE TO BE INSTALLED IN A CONTINUOUS ROW. COORDINATE AND PROVIDE NECESSARY CONNECTORS, ENDCAPS, AND APPURTENANCES TO ENABLE CLEAN CONTINUOUS LINES OF LIGHT.

6 PROVIDE BASE/MOUNTING PER MANUFACTURER'S INSTALLATION INSTRUCTIONS, COORDINATE WITH LANDSCAPE ARCHITECT/CIVIL ENGINEER.

7 REFER TO MANUFACTURERS INSTRUCTIONS FOR INSTALLATION. INSTALL LUMINAIRE AT FRONT OF CABINET

F BATTERY PACKS INSTALLED OUTDOORS SHALL HAVE LOW TEMP CAPABILITY SUITABLE FOR THE ENVIRONMENT IT IS INSTALLED.

G FIXTURES SHOWN WITH "E" AT END OF TAG - PROVIDE WITH INTEGRAL BATTERY PACK AND INTEGRAL TEST SWITCH. CONNECT POWER SENSE WIRE TO UNSWITCHED LEG.

LG1B LINEAR LED

OUTDOOR INGRADE

WALL GRAZER

INGRADE 840LM/FT N/A INTEGRAL 277 15.25W/FT 60.13

LM/W

2.5 DEGREE TILT SETTING,

WALLWASH OPTICS

PROVIDE INTERNAL LOUVER AND

ANTI-SLIP LENS, EXACT LENGTHS

PER PLANS

3,4,5

LED 0-10V

3500K CCT DIMMING

DRIVER

LI1 4' LINEAR LED

INDUSTRIAL STRIP

SURFACE/

SUSPEND PER

ARCHITECTURAL

CEILINGS

3000 LM N/A INTEGRAL UNIV 41 72 LM/W MEDIUM DIFFUSE DIFFUSER COLD-ROLLED STEEL HOUSING, FINISH TBS, CONTINUOUS LENGTHS

PER PLANS

1,2,3

LED DRIVER

PACKAGE

3500K CCT

MIN 83 CRI

TAG IMAGE DESCRIPTION

INSTALLATION LIGHT SOURCE BALLAST/DRIVER INPUT

WATTS

MIN.

EFF.

SHIELDING/OPTICS FEATURES/OPTIONS NOTES

METHOD SPEC QTY SPEC VOLT

LX6 EXTERIOR LED SIGN

LIGHT

AT GRADE 2637 LM N/A INTEGRAL UNIV 50 55.4

LM/W

80 DEGREE WIDE FLOOD

DISTRIBUTION, 90 DEGREE CUTOFF

CAP STYLE WITH WEEP-HOLE,

TEMPERED GLASS LENS

PROVIDE RECTILINEAR LENS AND

ROTATIONAL KNUCKLE MOUNTING

SYSTEM, FINISH TBS, SILICONE O

RING GASKETING, PROVIDE ALL

NECESSARY REMOTE

TRANSFORMERS/POWER

SUPPLIES

3,6

LED 0-10V

PACKAGE DIMMING

4000K CCT DRIVER

MIN 90 CRI

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/1

/2

:3

:1

A

M C

U s e rs

\b jh o ff m a n n \D o c u m e n ts

\A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

E

E P h a s e

B b jh o ff m a n n .r v t

EL101

LIGHTING FLOOR PLAN AND

LUMINAIRE SCHEDULE

SMW BSM

LIGHTING FLOOR PLAN AND

LUMINAIRE SCHEDULE

1. EXTEND BRANCH CIRCUITS IN THIS AREA TO THE FOLLOWING BRANCH PANELBOARDS,

UNLESS OTHERWISE NOTED:

120 / 208V PANELBOARDS

CS2 - NORMAL POWER

BRANCH CIRCUIT NOTES :

SEE BRANCH CIRCUIT

NOTES (TYPICAL)

1/8" = 1'-0" F7

COMMITTAL SHELTER NUMBER 2 1

WW

5.B 1.B 2B

A.B

D.B

B.B

C.B

1.2B 1.5B

1.4B

1.3B

CEILING FAN

CONNECTION

CS2

SHELTER

B-100

CLOSET

B-101

MOUNT RECEPTACLE

IN CABINET, SEE

DETAIL F6/TA101

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/1

/2

:3

:1

A

M C

U s e rs

\b jh o ff m a n n \D o c u m e n ts

\A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

E

E P h a s e

B b jh o ff m a n n .r v t

EP101

POWER FLOOR PLAN AND PANEL

SCHEDULE

SMW BSM

POWER FLOOR PLAN AND PANEL

SCHEDULE

1. EXTEND BRANCH CIRCUITS IN THIS AREA TO THE FOLLOWING BRANCH PANELBOARDS,

UNLESS OTHERWISE NOTED:

120 / 208V PANELBOARDS

CS2 - NORMAL POWER

BRANCH CIRCUIT NOTES :

SEE BRANCH CIRCUIT

NOTES (TYPICAL)

1/8" = 1'-0" F8

COMMITAL SHELTER NUMBER 2

Notes:

Total Est. Demand: 5 A

Total Conn.: 4 A

Receptacle 800 VA 100.00% 800 VA Total Est. Demand: 1667 VA

Lighting 534 VA 125.00% 667 VA Total Conn. Load: 1534 VA

HVAC 200 VA 100.00% 200 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 9 A 6 A 0 A

Total Load: 934 VA 600 VA 0 VA

11 12

9 10

7 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 8

5 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 6

3 R: B-101 20 A 1 400 VA 200 VA 1 20 A R: B-100 CEILING FAN 4

1 R: B-100 20 A 1 400 VA 534 VA 1 20 A L: B-100, B-101 2

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Notes:

Enclosure: Type 1 MCB Rating: 30 A

Mounting: Surface Wires: 4 Mains Rating: 100 A

Supply From: CS-DP Phases: 3 Mains Type: MCB

Location: CLOSET B-101 Volts: 120/208 Wye A.I.C. Rating: 10K

NEW Branch Panel: CS2

RGS OR IMC

PVC CONDUIT

PVC TO RIGID

ADAPTER

WRAP ALL JOINTS

100% WATERTIGHT

FINISHED FLOOR

THREADED CAP ON ALL SPARESTO COUPLING, PULLBOX,

PANELBOX, ETC. AS

SHOWN OR REQUIRED

TYPICAL-SEAL VAPOR

BARRIER TO CONDUIT

TYPICAL-TIE REBARS

WITH #3 BARS

RGS OR IMC

TYPICAL #4 REBARS

6" O.C. ALL AROUND

TYPICAL-CONCRETE

BLOCKS. LENGTH AS

REQUIRED

KEYED NOTES :

1. AT EACH CONDUIT STUB-UP, AFFIX ENGRAVED PLASTIC NAMEPLATE INDICATING

CONDUIT NO. OR CIRCUIT IDENTIFICATION. ATTACH WITH NYLON CABLE TIE.

50/51 RELAY

DANGER

DO NOT USE TO START

OR STOP MOTOR.

USE FOR ISOLATION

ONLY.

MOTOR DISCONNECT SWITCH

WARNING LABEL

(3/8" TEXT)

IDENTIFICATION LABEL

(1/4" TEXT)

2"

/4

DISCONNECT SWITCH, MOTOR CONTROLLER,

SEPERATLY ENCLOSED CIRCUIT BREAKER, OR CONTACTOR

(FRONT VIEW)

KEYED NOTES

1. EQUIPMENT IDENTIFICATION LABEL.

2. WARNING LABEL UNGROUNDED

CONDUCTORS (VOLTAGE LABEL).

3. TESTING LABEL.

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/1

/2

:3

:0

A

M C

U s e rs

\b jh o ff m a n n \D o c u m e n ts

\A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

E

E P h a s e

B b jh o ff m a n n .r v t

E-501

ELECTRICAL DETAILS

SMW BSM

ELECTRICAL DETAILS

D8

CONDUIT STUB-UP INSIDE BUILDING

F8

ELECTRICAL IDENTIFICATION LABELS

B8

MISC. PROTECTIVE DEVICES IDENTIFICATIONS

LEVEL 01 LEVEL 01

A/P-T2

75KVA

480V TO

208/120V

A/P-R1 A/P-L1 A/P-M1

A/P-LDP, 400A, 208/120V

PIC/ADMIN

150A 60A 100A

A/P-HDP, 400 A, 480/277 V

A/P-T1

112.5 KVA

13,200V TO

480/277V

400A

NATIONAL GRID (NG)

OH SERVICE

13,200V, 3 PHASE, 60HZ

NG RISER POLE

10E

250A SPD

60A 110A 20A

-1P SPD

TO SITE

LIGHTING

CKT #4

CS-D-T1

CS-T1

30KVA

480V TO

208/120V

30A

CS1

60A

HG1

100A 30A SPD

CS-DP, 225A BUSS, 208/120V

F90/4 F30/4 F150/4 F60/4 F100/4

F250/T4

F125/3

F100/T4

F50/3

45A

1F200/4

2#2, #2G -1"C

60A

TO IRRIGATION

BOOSTER PUMP,

SEE SHEET

ES102

3#300, #4G - 2 1/2"C

M

M

3 TYPICAL

10kAIC

14kAIC

10kAIC

G

N

100A

SPACE 15A

MM

3#12, #12G

- 3/4"C

DWBP-1

SPACE SPACE

COMMITAL SHELTER 1

CS2

NEW WORK

BID OPTION 2

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/1

/2

:3

:0

A

M C

U s e rs

\b jh o ff m a n n \D o c u m e n ts

\A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

E

E P h a s e

B b jh o ff m a n n .r v t

E-601

POWER RISER DIAGRAM AND

SCHEDULES

SMW BSM

POWER RISER DIAGRAM AND

SCHEDULES

F5

POWER RISER - EXISTING

FEEDER DESIGNATIONS - COPPER CONDUCTOR

FEEDER ID AMPS

PHASE WIRES

(AWG)

NEUTRAL WIRES

(AWG) GND (AWG)

MIN. CONDUIT

SIZE FEEDER ID AMPS

PHASE WIRES

(AWG)

NEUTRAL WIRES

(AWG) GND (AWG)

MIN. CONDUIT

SIZE

30/3 30 (3)#10 #10 3/4 400/3 400 (6)#3/0 (2)#2 (2)2

30/4 30 (3)#10 (1)#10 #10 3/4 400/4 400 (6)#3/0 (2)#3/0 (2)#2 (2)2

30/5 30 (3)#10 (1)#6 #10 3/4 400/5 400 (6)#3/0 (4)#3/0 (2)#2 (2)2-1/2

40/3 40 (3)#8 #10 3/4 500/3 500 (6)250KCMIL (2)#2 (2)2-1/2

40/4 40 (3)#8 (1)#8 #10 3/4 500/4 500 (6)250KCMIL (2)250KCMIL (2)#2 (2)2-1/2

40/5 40 (3)#8 (1)#2 #10 1 500/5 500 (6)250KCMIL (4)250KCMIL (2)#2 (2)3

50/3 50 (3)#6 #10 1 600/3 600 (6)350KCMIL (2)#1 (2)2-1/2

50/4 50 (3)#6 (1)#6 #10 1-1/4 600/4 600 (6)350KCMIL (2)350KCMIL (2)#1 (2)3

50/5 50 (3)#6 (1)#2 #10 1-1/4 600/5 600 (6)350KCMIL (4)350KCMIL (2)#1 (2)3

60/3 60 (3)#4 #10 1-1/4 700/3 700 (6)500KCMIL (2)#1/0 (2)3

60/4 60 (3)#4 (1)#4 #10 1-1/4 700/4 700 (6)500KCMIL (2)500KCMIL (2)#1/0 (2)3-1/2

60/5 60 (3)#4 (1)1/0 #10 1-1/4 700/5 700 (6)500KCMIL (4)500KCMIL (2)#1/0 (2)3-1/2

70/3 70 (3)#4 #8 1-1/4 800/3 800 (9)300KCMIL (3)#1/0 (3)2-1/2

70/4 70 (3)#4 (1)#4 #8 1-1/4 800/4 800 (9)300KCMIL (3)300KCMIL (3)#1/0 (3)3

70/5 70 (3)#4 (1)#1/0 #8 1-1/4 800/5 800 (9)300KCMIL (6)300KCMIL (3)#1/0 (3)3

90/3 90 (3)#2 #8 1-1/4 1000/3 1000 (9)400KCMIL (3)#2/0 (3)3

90/4 90 (3)#2 (1)#2 #8 1-1/4 1000/4 1000 (9)400KCMIL (3)400KCMIL (3)#2/0 (3)3

90/5 90 (3)#2 (1)#3/0 #8 1-1/2 1000/5 1000 (9)400KCMIL (6)400KCMIL (3)#2/0 (3)3-1/2

100/3 100 (3)#1 #8 1-1/4 1200/3 1200 (12)350KCMIL (4)#3/0 (4)2-1/2

100/4 100 (3)#1 (1)#1 #8 1-1/2 1200/4 1200 (12)350KCMIL (4)350KCMIL (4)#3/0 (4)3

100/5 100 (3)#1 (1)#3/0 #8 2 1200/5 1200 (12)350KCMIL (8)350KCMIL (4)#3/0 (4)3

125/3 125 (3)#1 #6 1-1/2 1500/3 1500 (12)500KCMIL (4)#4/0 (4)3

125/4 125 (3)#1 (1)#1 #6 1-1/2 1500/4 1500 (12)500KCMIL (4)500KCMIL (4)#4/0 (4)3-1/2

125/5 125 (3)#1 (1)250KCMIL #6 2 1500/5 1500 (12)500KCMIL (8)500KCMIL (4)#4/0 (4)3-1/2

150/3 150 (3)#1/0 #6 1-1/2 1600/3 1600 (15)400KCMIL (5)#4/0 (5)3

150/4 150 (3)#1/0 (1)#1/0 #6 2 1600/4 1600 (15)400KCMIL (5)400KCMIL (5)#4/0 (5)3

150/5 150 (3)#1/0 (2)#1/0 #6 2 1600/5 1600 (15)400KCMIL (10)400KCMIL (5)#4/0 (5)3-1/2

175/3 175 (3)#2/0 #6 1-1/2 2000/3 2000 (18)400KCMIL (6)250KCMIL (6)3

175/4 175 (3)#2/0 (1)#2/0 #6 2 2000/4 2000 (18)400KCMIL (6)400KCMIL (6)250KCMIL (6)3

175/5 175 (3)#2/0 (2)#2/0 #6 2 2000/5 2000 (18)400KCMIL (12)400KCMIL (6)250KCMIL (6)3-1/2

200/3 200 (3)#3/0 #6 2 2500/3 2500 (24)400KCMIL (8)350KCMIL (8)3

200/4 200 (3)#3/0 (1)#3/0 #6 2 2500/4 2500 (24)400KCMIL (8)400KCMIL (8)350KCMIL (8)3

200/5 200 (3)#3/0 (2)#3/0 #6 2-1/2 2500/5 2500 (24)400KCMIL (16)400KCMIL (8)350KCMIL (8)3

225/3 225 (3)#4/0 #4 2 3000/3 3000 (24)500KCMIL (8)400KCMIL (8)3-1/2

225/4 225 (3)#4/0 (1)#4/0 #4 2-1/2 3000/4 3000 (24)500KCMIL (8)500KCMIL (8)400KCMIL (8)4

225/5 225 (3)#4/0 (2)#4/0 #4 2-1/2 3000/5 3000 (24)500KCMIL (16)500KCMIL (8)400KCMIL (8)4

250/3 250 (3)250KCMIL #4 2-1/2 3200/3 3200 (27)500KCMIL (9)400KCMIL (9)3-1/2

250/4 250 (3)250KCMIL (1)250KCMIL #4 2-1/2 3200/4 3200 (27)500KCMIL (9)500KCMIL (9)400KCMIL (9)4

250/5 250 (3)250KCMIL (2)250KCMIL #4 3 3200/5 3200 (27)500KCMIL (18)500KCMIL (9)400KCMIL (9)4

300/3 300 (3)350KCMIL #4 2-1/2 4000/3 4000 (33)500KCMIL (11)500KCMIL (11)3

300/4 300 (3)350KCMIL (1)350KCMIL #4 3 4000/4 4000 (33)500KCMIL (11)500KCMIL (11)500KCMIL (11)3-1/2

300/5 300 (3)350KCMIL (2)350KCMIL #4 3 4000/5 4000 (33)500KCMIL (22)500KCMIL (11)500KCMIL (11)4

350/3 350 (3)500KCMIL #2 3

350/4 350 (3)500KCMIL (1)500KCMIL #2 3-1/2

350/5 350 (3)500KCMIL (2)500KCMIL #2 3-1/2

TRANSFORMER SECONDARY FEEDER DESIGNATIONS - COPPER CONDUCTORS

FEEDER ID

XFMR

SIZE (KVA)

PHASE WIRES

(AWG)

NEUTRAL WIRES

(AWG) GND (AWG)

MIN. CONDUIT

SIZE GEC FEEDER ID

XFMR

SIZE (KVA)

PHASE WIRES

(AWG)

NEUTRAL WIRES

(AWG) GND (AWG)

MIN. CONDUIT

SIZE GEC

30/T4 9 (3)#8 (1)#8 #8 1 A 600/T4 150 (6)250KCMIL (2)250KCMIL (2)#1/0 (2)2-1/2 D

30/T5 9 (3)#8 (1)#2 #8 1 A 600/T5 150 (6)250KCMIL (4)250KCMIL (2)#1/0 (2)3 D

50/T4 15 (3)#6 (1)#6 #8 1-1/4 A 800/T4 225 (9)300KCMIL (3)300KCMIL (3)#2/0 (3)3 E

50/T5 15 (3)#6 (1)#2 #8 1-1/4 A 800/T5 225 (9)300KCMIL (6)300KCMIL (3)#2/0 (3)3 E

100/T4 30 (3)#1 (1)#1 #6 1-1/2 B 1000/T4 300 (9)400KCMIL (3)400KCMIL (3)#3/0 (3)3 F

100/T5 30 (3)#1 (1)#3/0 #6 2 B 1000/T5 300 (9)400KCMIL (6)400KCMIL (3)#3/0 (3)3-1/2 F

150/T4 45 (3)#1/0 (1)1/0 #6 2 B 1600/T4 500 (15)400KCMIL (5)400KCMIL (5)#4/0 (5)3 F

150/T5 45 (3)#1/0 (2)#1/0 #6 2 B 1600/T5 500 (15)400KCMIL (10)400KCMIL (5)#4/0 (5)3-1/2 F

250/T4 75 (3)250KCMIL (1)250KCMIL #2 2-1/2 C 2500/T4 750 (18)600KCMIL (6)600KCMIL (6)350KCMIL (6)4 F

250/T5 75 (3)250KCMIL (2)250KCMIL #2 3 C 2500/T5 750 (15)600KCMIL (12)600KCMIL (6)350KCMIL (6)4 F

400/T4 112.5 (6)#3/0 (2)#3/0 (2)#1/0 (2)2 D 3000/T4 1000 (24)400KCMIL (8)400KCMIL (8)400KCMIL (8)3 F

400/T5 112.5 (6)#3/0 (4)#3/0 (2)#1/0 (2)2-1/2 D 1000/T5 1000 (24)400KCMIL (16)400KCMIL (8)400KCMIL (8)3-1/2 F

1. SEE ELECTRICAL SITE PLAN FOR CHANGES IN CONDUIT SIZES IN DUCTBANKS. SIZE

SHOWN ON RISER IS FOR FEEDERS INSIDE BUILDING.

2. INTERFACE KWHR METER TO BUILDING MANAGEMENT SYSTEM. SEE SPECIFICATIONS.

3. ALL CIRCUIT BREAKERS SHOWN ARE 3-POLE UNLESS OTHERWISE NOTED.

4. SEE SITE PLAN FOR FEEDER SIZE.

KEYED NOTES :

NEW WORK

BID OPTION 2

R

C K

LL

5.B 1.B 2B

A.B

D.B

B.B

C.B

1.2B 1.5B

1.4B

1.3B

W

RECESSED LOUDSPEAKER IN

WALL TO MATCH EXISTING

COMMITAL SERVICE SHELTER -

TYPICAL

SHELTER

B-100

CLOSET

B-101

1. FOR EXACT LOCATION AND FINISHED SURFACE CONDITIONS OF MILLWORK, CEILING, WALL, OR FLOOR MOUNTED DEVICES, REFER

TO ARCHITECTURAL DRAWINGS.

2. FOR EXACT LOCATION OF FACILITY FIRE RATED WALLS AND SMOKE WALLS, REFER TO ARCHITECTURAL DRAWINGS.

3. MOUNTING HEIGHTS ARE TO CENTER OF DEVICE OR EQUIPMENT, UNLESS NOTED OTHERWISE.

4. CONFIRM ALL LABELS AND ROOM NUMBERS WITH VETERANS AFFAIRS, (VA), PRIOR TO FINALIZING LABELING AND PROGRAMMING.

5. COORDINATE FINAL OUTLET LOCATIONS WITH ALL TRADES AND FURNITURE/MILLWORK PLACEMENT PRIOR TO ROUGH-IN.

6. PROVIDE GROUNDING PER NEC AND TIA 607B.

7. CONDUIT ROUTING SHOWN FOR INTENT. COORDINATE WITH ALL TRADES.

8. IN EACH INSTANCE WHERE TWO OR MORE LIKE OR UNLIKE DEVICE BOXES ARE GENERALLY LOCATED IN THE SAME VICINITY AND AT DIFFERENT ELEVATIONS, MOUNT THE BOXES VERTICALLY ON A COMMON CENTERLINE. COORDINATE WITH ALL TRADES.

9. COORDINATE HEIGHT AND LOCATION OF OUTLETS WITH EQUIPMENT MOUNTING BRACKETS AND BLOCKING IN WALL.

NEMA 12

CABINET ENCLOSURE

L L

DIGITAL MESSAGE

REPEATER (DMR)

UPS

POWER RECEPTACLE

SPEAKER WIRING 18/2 TSP

IN CONDUIT

PUSHBUTTON WIRING 20/2 CABLE

SURFACE MOUNT MOMENTARY

CONTACT PUSHBUTTON, SEE DETAILS

E9 AND C9, THIS SHEET

B

A

C

D

E

F

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BID DOCUMENTS

ATIONAL

EMETERY

DMINISTRATIONA

C

N

Drawing Title

GENESEE COUNTY, NEW YORK

Project Title

Location

Date Checked Drawn

936CM2002

Drawing Number

Building Number

Project Number

Management

02-08-21 Dwg of

V

T

N T I

D

STA

E

U

E

N T

OF

I

C

ES OF

R I

AM

E

R

A

S

S

ETERAN

AF

F A

Revisions:

VA FORM 08-6231, OCT 1978

CONSULTANTS:

Date

ARCHITECT/ENGINEER:

ATIONAL

EMETERY

DMINISTRATIONA

C

N

WESTERN NEW YORK

NATIONAL CEMETERY

PHASE 1B DEVELOPMENT and Facilities

Office of

Construction

LEO A DALY Company 2017

/1

/2

:3

:2

A

M C

U s e rs

\b jh o ff m a n n \D o c u m e n ts

\A u to d e s k \R e v it

P ro je c ts

\V A

C e m e te ry W

N Y

E

E P h a s e

B b jh o ff m a n n .r v t

TA101

AUDIO VISUAL FLOOR PLAN AND

DETAILS

SMW BSM

AUDIO VISUAL FLOOR PLAN AND

DETAILS

1. AUDIO SYSTEM RACK. REFER TO F6/TA101 FOR FOR AUDIO SYSTEM RISER DIAGRAM.

2. INSTALL CABLE ENTIRELY IN MULLION. CABLE SHALL NOT BE ROUTED ON SURFACE OR IN

ANY SURFACE MOUNTED RACEWAY. SURFACE MOUNT BOX FOR MOMENTARY

PUSHBUTTON TO MULLION AT 48" AFG. VERIFY FINAL LOCATION OF PUSHBUTTON WITH V.A.

KEYED NOTES :

0 8' 16'

1/8" = 1'-0" F8

COMMITAL SERVICE SHELTER 2 AUDIO/ VISUAL PLAN

TELECOMMUNICATIONS/SECURITY/AUDIOVISUAL GENERAL NOTES

1/8" = 1'-0" F6

AUDIO SYSTEM RISER

6" = 1'-0" D6

PUSH BUTTON COVER

6" = 1'-0" C6

TYPICAL PUSH BUTTON SWITCH

387_936CM2002AE602
Sheets
AE001 - SYMBOLS & ABBREVIATIONS
AE102 - COMMITTAL SERVICE SHELTER NO.2 FLOOR PLAN, ROOF PLAN AND ELEVATIONS
AE122 - COMMITTAL SERVICE SHELTER NO.2 REFLECTED CEILING PLAN
AE302 - COMMITTAL SERVICE SHELTER NO.2 BUILDING SECTIONS
AE313 - EXTERIOR WALL SECTIONS AND DETAILS
AE501 - ENLARGED DETAILS
AE602 - DOOR SCHEDULE, TYPES AND DETAILS
396_936CM2002P-103
Sheets
P-103 - PLUMBING PLAN - COMMITTAL SERVICE SHELTER 2
415_936CM2002E-001
Sheets
E-001 - ELECTRICAL SYMBOLS & ABBREVIATIONS
E-501 - ELECTRICAL DETAILS
E-601 - POWER RISER DIAGRAM AND SCHEDULES
EL101 - LIGHTING FLOOR PLAN AND LUMINAIRE SCHEDULE
EP101 - POWER FLOOR PLAN AND PANEL SCHEDULE
ES101 - ELECTRICAL SITE PLAN AREA A
ES102 - ELECTRICAL SITE PLAN AREA B
TA101 - AUDIO VISUAL FLOOR PLAN AND DETAILS
416_936CM2002ES101
Sheets
ES101 - ELECTRICAL SITE PLAN AREA A
417_936CM2002ES102
Sheets
E-001 - ELECTRICAL SYMBOLS & ABBREVIATIONS
E-501 - ELECTRICAL DETAILS
E-601 - POWER RISER DIAGRAM AND SCHEDULES
EL101 - LIGHTING FLOOR PLAN AND LUMINAIRE SCHEDULE
EP101 - POWER FLOOR PLAN AND PANEL SCHEDULE
ES101 - ELECTRICAL SITE PLAN AREA A
ES102 - ELECTRICAL SITE PLAN AREA B
TA101 - AUDIO VISUAL FLOOR PLAN AND DETAILS
419_936CM2002EL101
Sheets
E-001 - ELECTRICAL SYMBOLS & ABBREVIATIONS
E-501 - ELECTRICAL DETAILS
E-601 - POWER RISER DIAGRAM AND SCHEDULES
EL101 - LIGHTING FLOOR PLAN AND LUMINAIRE SCHEDULE
EP101 - POWER FLOOR PLAN AND PANEL SCHEDULE
ES101 - ELECTRICAL SITE PLAN AREA A
ES102 - ELECTRICAL SITE PLAN AREA B
TA101 - AUDIO VISUAL FLOOR PLAN AND DETAILS
421_936CM2002EP101
Sheets
E-001 - ELECTRICAL SYMBOLS & ABBREVIATIONS
E-501 - ELECTRICAL DETAILS
E-601 - POWER RISER DIAGRAM AND SCHEDULES
EL101 - LIGHTING FLOOR PLAN AND LUMINAIRE SCHEDULE
EP101 - POWER FLOOR PLAN AND PANEL SCHEDULE
ES101 - ELECTRICAL SITE PLAN AREA A
ES102 - ELECTRICAL SITE PLAN AREA B
TA101 - AUDIO VISUAL FLOOR PLAN AND DETAILS
423_936CM2002E-501
Sheets
E-001 - ELECTRICAL SYMBOLS & ABBREVIATIONS
E-501 - ELECTRICAL DETAILS
E-601 - POWER RISER DIAGRAM AND SCHEDULES
EL101 - LIGHTING FLOOR PLAN AND LUMINAIRE SCHEDULE
EP101 - POWER FLOOR PLAN AND PANEL SCHEDULE
ES101 - ELECTRICAL SITE PLAN AREA A
ES102 - ELECTRICAL SITE PLAN AREA B
TA101 - AUDIO VISUAL FLOOR PLAN AND DETAILS
424_936CM2002E-601
Sheets
E-001 - ELECTRICAL SYMBOLS & ABBREVIATIONS
E-501 - ELECTRICAL DETAILS
E-601 - POWER RISER DIAGRAM AND SCHEDULES
EL101 - LIGHTING FLOOR PLAN AND LUMINAIRE SCHEDULE
EP101 - POWER FLOOR PLAN AND PANEL SCHEDULE
ES101 - ELECTRICAL SITE PLAN AREA A
ES102 - ELECTRICAL SITE PLAN AREA B
TA101 - AUDIO VISUAL FLOOR PLAN AND DETAILS
430_936CM2002TA101
Sheets
E-001 - ELECTRICAL SYMBOLS & ABBREVIATIONS
E-501 - ELECTRICAL DETAILS
E-601 - POWER RISER DIAGRAM AND SCHEDULES
EL101 - LIGHTING FLOOR PLAN AND LUMINAIRE SCHEDULE
EP101 - POWER FLOOR PLAN AND PANEL SCHEDULE
ES101 - ELECTRICAL SITE PLAN AREA A
ES102 - ELECTRICAL SITE PLAN AREA B
TA101 - AUDIO VISUAL FLOOR PLAN AND DETAILS

File details come from the government source that posted it. Updated .