9-3. 2026 03 10 Hub IFC Arch.pdf

PDF 26 MB Posted

Attached to
28th St Hub Doors, Frames & Hardware
Solicitation number
BID-269-26
Issued by
Boulder County, Colorado

About this file

This is an Invitation for Bid (IFB) issued by Boulder County Building Services, a Division of Public Works, for the furnishing of interior doors, frames, and hardware for the Boulder County Community Hub located at 2525 28th Street, Boulder, Colorado 80301. The project is a 39,560-square-foot, two-story non-residential office tenant improvement and roof replacement for Boulder County, with work exceeding 50 percent of the building area. The bid documents include comprehensive architectural drawings and specifications detailing all required materials, including door schedules, frame types, hardware sets, and installation requirements across multiple levels (lower level parking garage, Level 1, and Level 2). The project team includes representatives from various disciplines such as structural engineering, sustainability consulting, architecture, civil engineering, landscape design, cost estimation, and mechanical/electrical trades. Installation of all furnishings is to be performed by Boulder County as the General Contractor, with bidders required to furnish materials only. Bidders may submit product substitutions that meet or exceed all quality and capacity requirements, provided they comply with specifications; however, certain materials designated as "Basis-of-Design" products cannot be substituted.

The bid documents specify that all bidders must comply with quality, capacity, and specification requirements outlined in the architectural and construction documents dated March 10, 2026 (100% IFC set). Proposed product substitutions must be submitted with bid questions and do not require a formal substitution request form. The procurement process is administered by Boulder County, and inquiries regarding procurement procedures should be directed to procurement@bouldercounty.gov. All work must comply with the 2024 International Building Code, applicable Colorado codes, and local amendments as specified in the project documents. The project includes detailed door schedules identifying specific hardware sets, frame finishes, and installation locations throughout the facility. Americans with Disabilities Act (ADA) and Equal Opportunity compliance requirements apply to all bidders and their proposed work.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TRUE

NORTH

BOULDER COUNTY PUBLIC WORKS

KARLA SCHULTZ

2525 13TH STREET

BOULDER, CO 80304

PHONE: 720.415.5766

STRUCTURAL

LAURA A. COATES

JVA INC.

STREET1319 SPRUCE ST

BOULDER, CO 80302

PHONE: 303.565.4939

SUSTAINABILITY CONSULTANT

LAURA CHARLIER

GROUP 14

1325 EAST 16TH AVE

DENVER, CO 80218

PHONE: 720.221.1074

ARCHITECT

OZ ARCHITECTURE

TRACY BOYER

3003 LARIMER STREET

DENVER, CO, 80205

PHONE: 303.861.5704

CIVIL

CODY F. GRANTY

JVA INC.

1319 SPRUCE ST

BOULDER, CO 80302

PHONE: 303.565.4966

LANDSCAPE

SANDI GIBSON

OUTSIDE L.A.

BOULDER, CO

PHONE: 303.517.9256

COST ESTIMATOR

MELISSA CHABOT

VERMEULENS

100 FILMORE ST

DENVER, CO 80206

PHONE: 857.294.0677

ELECTRICAL / TECHNOLOGY

BRIAN D. JOHNSON

AE DESIGN

1900 WAZEE ST SUITE 205

DENVER, CO 80202

PHONE: 303.296.3036

MECHANICAL / PLUMBING

MILES DAKE

DAKE COLLABORATIVE

3435 S INCA ST, SUITE C

ENGLEWOOD, CO 80110

PHONE: 720.583.4735

SIG

NATURE B

LO

CK

/1

/2

:5

:1

P

M A u to d e s k D o c s /1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

/1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

A

.r v t

BOULDER COUNTY COMMUNITY HUB

100% IFC - 20260309

2525 28th St.

Boulder, Co 80301

IMAGE IS REPRESENTATIVE ONLY

SET ISSUE INDEX VICINITY MAP PROJECT TEAM

03.10.2026

STRUCTURAL GRID WINDOW IDENTIFICATION

DOOR IDENTIFICATION

GLAZING IDENTIFICATION

FLAG NOTE IDENTIFICATION

ROOM/SPACE IDENTIFICATION ROOM/FINISH IDENTIFICATION

RCP/FINISH IDENTIFICATION

CODE ROOM/SPACE IDENTIFICATION

ELEVATION REFERENCE

MATERIAL PATTERNS

BUILDING SECTION IDENTIFICATION

WALL/DETAIL SECTION IDENTIFICATION

ENLARGED DETAIL IDENTIFICATION

PARTITION TYPE IDENTIFICATION

ACOUSTIC PARTITION TYPE

IDENTIFICATION

ASSEMBLY IDENTIFICATION

C

COLUMN NUMBER

COLUMN GRID

REFERENCE LINE

COLUMN LETTER

WINDOW TYPE

A

G2

GLAZING TYPE

DOOR NUMBER

ROOM NAME

ROOM NUMBER

ROOM AREA*

ROOM NAME

ROOM NUMBER

CPT-01

WALL FIN.

BASE TYPE

FLOOR FIN. TYPE

ROOM NAME

ROOM NUMBER

CEILING FIN.

ELEVATION

DATUM POINT

LOCATION

102' - 6"

DRAWING NUMBER

SHEET NUMBER

DRAWING NUMBER

SHEET NUMBER

23A

PARTITION TYPE

RE: PARTITION

TYPE SHEET

HEAD OF WALL TYPE RE:

PARTITION TYPE SHEET

23A

PARTITION TYPE

RE: PARTITION

TYPE SHEET

HEAD OF WALL TYPE RE:

PARTITION TYPE SHEET

E1

EXTERIOR WALL

ASSEMBLY TYPE

F1

FLOOR

ASSEMBLY TYPE

C2

CEILING

ASSEMBLY TYPE

R3

ROOF

ASSEMBLY TYPE

* ROOM AREAS:

VERIFY BASIS OF MEASUREMENT USED BY ARCHITECT. MAY BE CALCULATED TO

CENTERLINE OF SURROUNDING PARTITIONS OR TO INSIDE FINISH SURFACES.

CONCRETE

UNDISTURBED OR

COMPACTED EARTH

POROUS FILL

(GRAVEL)

STEEL

ALUMINUM

MASONRY - BRICK

MASONRY -

CONCRETE BLOCK

INSULATION - RIGID

INSULATION - BATT

GYPSUM - PLASTER

PLYWOOD

FINISH WOOD

ROUGH WOOD

ACOUSTIC TILE

9.15 NOTE NUMBER

FINISH IDENTIFICATION

P FINISH TYPE

ACCESSORY IDENTIFICATION

ACCESSORY TYPE1i

DRAWING NUMBER

SHEET NUMBER

/ A

-3

2 / A-401

ROOM

788 SF GROSS

RESIDENTIAL

R-2

200 SF/OCC

3 OCCUPANTS

1 EXITS REQ'D

ROOM NAME

AREA* & TYPE (GROSS OR NET)

FUNCTION OF SPACE

(TABLE 1004.1.2)

OCCUPANT LOAD FACTOR

TOTAL OCCUPANTS

EXITS REQUIRED

OCCUPANCY GROUP

RB-01

P-01

ROOM

P-01

ROOM

ROOM

2,828 SF

/ A

-3

INTERIOR ELEV. IDENTIFICATION

EXTERIOR ELEV. IDENTIFICATION

DRAWING NUMBER

SHEET NUMBERA-701

DRAWING NUMBER

SHEET NUMBER

2 / A-201

H W D

MOD DESCRIPTION UNIQUE MODIFIER

CASEWORK IDENTIFICATION

CASEWORK DESIGN

SERIES (CDS) NUMBER

CASEWORK DIMENSION

DIMENSION IDENTIFICATION

X'-X"

X'-X"

MEASURED FROM

FACE OF STUD, UNO

MEASURED FROM

FACE OF FINISH, UNO

1. THE TERM “GC” SHALL MEAN THE GENERAL CONTRACTOR AND ITS SUB-CONTRACTORS.

2. THE GC SHALL THOROUGHLY FAMILIARIZE ITSELF WITH THE CONTRACT DOCUMENTS AND THE SITE.

SHOULD THE GC FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS, SHOULD THE GC BE IN DOUBT AS TO THEIR INTENT OR MEANING, OR HAS QUESTIONS CONCERNING

CONSTRUCTABILITY OR CODE COMPLIANCE, THE GC SHALL SEEK CLARIFICATION FROM THE

ARCHITECT BEFORE PROCEEDING WITH THE WORK. SHOULD A CONFLICT OCCUR BETWEEN THE

DRAWINGS AND SPECIFICATIONS, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT.

3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO PROVIDE A COMPLETE PROJECT. EVERY ITEM NECESSARILY REQUIRED MAY NOT BE SPECIFICALLY MENTIONED OR SHOWN. UNLESS EXPRESSLY STATED, SYSTEMS AND EQUIPMENT SHALL BE COMPLETELY OPERATIONAL. PROVIDE INCIDENTAL, ACCESSORY, AND ANY OTHER ITEMS NOT SPECIFIED, BUT REQUIRED, FOR A COMPLETE AND

FINISHED ASSEMBLY.

4. THE ENTIRE SET OF CONTRACT DOCUMENTS REPRESENT THE PROJECT AS A WHOLE. THE GC IS RESPONSIBLE FOR PROVIDING SUFFICIENT INFORMATION TO ITS SUB-CONTRACTORS TO DETERMINE

AND PERFORM THEIR SCOPE OF WORK.

5. ANY ELECTRONIC CAD AND/OR BUILDING INFORMATION MODELING (BIM) FILES PROVIDED BY THE

ARCHITECT OR ITS CONSULTANTS IS SOLELY TO ASSIST THE GC IN PREPARATION OF SHOP

DRAWINGS AND/OR LAYOUT OF THE PROJECT. CAD AND BIM FILES ARE NOT A PART OF THE

CONTRACT DOCUMENTS AND ANY INFORMATION CONTAINED THEREIN DOES NOT SUPERSEDE ANY

INFORMATION ON THE CONTRACT DOCUMENTS.

6. THE GC IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION, COORDINATION OF

TRADES, AND SCHEDULING OF THE WORK.

7. THE GC SHALL NOT REVISE, SUBSTITUTE, OR CHANGE THE WORK WITHOUT THE WRITTEN CONSENT

OF THE ARCHITECT.

8. NOT EVERY CONDITION MAY BE DRAWN OR DETAILED. CONDITIONS SIMILAR TO DETAILED

CONDITIONS SHALL BE CONSTRUCTED TO THE SAME SIZE AND CHARACTER AS THOSE FOR SIMILAR

CONDITIONS.

9. THE GC SHALL FOLLOW THE RECOMMENDATIONS OF THE OWNER’S GEOTECHNICAL CONSULTANT.

SHOULD THE GC FIND DISCREPANCIES WITH THE CONTRACT DOCUMENTS, THE GC SHALL SEEK

CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.

10. DO NOT SCALE DRAWINGS.

11. PROVIDE NECESSARY BLOCKING IN WALLS, PARTITIONS, AND CEILINGS FOR ITEMS INCLUDING, BUT

NOT LIMITED TO: CEILING AND PARTITION-MOUNTED FIXTURES, GRAB BARS, HANDRAILS, TOILET ACCESSORIES, CABINETRY, PANELING, COUNTERTOPS, SHELVES, CLOSET RODS, WHITE BOARDS, AND DECORATIVE ELEMENTS.

12. THE CONSTRUCTION DOCUMENTS ARE THE PROPERTY OF OZ ARCHITECTURE, INC. AND ITS

CONSULTANTS AND ARE TO BE USED AS INSTRUMENTS OF SERVICE FOR CONSTRUCTION OF THIS

PROJECT ONLY. USE OF THESE DOCUMENTS BY THE GC FOR ANY OTHER PROJECT OR PURPOSE

WITHOUT THE WRITTEN CONSENT OF OZ ARCHITECTURE IS PROHIBITED.

13. EL.100'-0" EQUATES TO USGS DATUM ELEVATION OF ______.

14. REFER TO ALTA SURVEY FOR BASIS OF BEARINGS, PROPERTY LINES, AND ASSOCIATED

INFORMATION.

15. REFER TO GEOTECHNICAL REPORT FOR ADDITIONAL CLARIFICATIONS ON SUB-GRADE DESIGN

RECOMMENDATIONS AND LIMITATIONS.

39,560 SF, 2 STORY NON-RESIDENTIAL BUILDING, OFFICE TENATE IMPROVEMENT FOR BOULDER

COUNTY

PROJECT NUMBER:

DATE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

REVISIONS:

/1

/2

:5

:1

P

M A u to d e s k D o c s /1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

/1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

A

.r v t BO

U

LD

ER

C

O U

N

TY

C O

M M

U N

IT

Y

H U

B

8t h

St

Bo ul de r, Co

125020.00

20260309

100% IFC

PROJECT INFORMATION,

ABBREVIATIONS, SHEET

INDEX

G-010

DRAWING INDEXABBREVIATIONS

GRAPHIC STANDARDS

GENERAL NOTES

PROJECT DESCRIPTION

# POUND(S) or NUMBER

& AND

< ANGLE

@ AT

AB ANCHOR BOLT

ACT ACOUSTICAL CEILING TILE

ADA AMERICAN DISABILITY ACT

ADD ADDENDUM

ADJ ADJACENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISH GRADE

AGGR AGGREGATE

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZED

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

APPROX APPROXIMATE

ARCH ARCHITECT / ARCHITECTURAL

ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS

ASPH ASPHALT

ASSY ASSEMBLY

AV AUDIO / VISUAL

AVE AVENUE

AVG AVERAGE

AWP ACOUSTICAL WALL PANEL

B.O. BOTTOM OF

BALC BALCONY

BD BOARD

BIM BUILDING INFORMATION MODELING

BLDG BUILDING

BLKG BLOCKING

BOD BASIS OF DESIGN

BR BEDROOM

BRG BEARING

BSMT BASEMENT

BTWN BETWEEN

CA CONSTRUCTION ADMINISTRATION

CAB CABINET

CCD CONSTRUCTION CHANGE DIRECTIVE

CCTV CLOSED CIRCUIT TELEVISION

CD CONSTRUCTION DOCUMENTS

CDOT COLORADO DEPARTMENT OF TRANSPORTATION

CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED

CFM COLD FORMED METAL

CG CORNER GUARD

CI CONTINUOUS INSULATION

CIP CAST IN PLACE

CJ CONTROL JOINT

CL CENTERLINE

CLG CEILING

CLL COLUMN LINE

CLO CLOSET

CLR CLEAR

CLT CROSS LAMINATED TIMBER

CM CENTIMETERS

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONF CONFERENCE

CONSTR CONSTRUCTION

CONT CONTINUOUS

CORR CORRIDOR

CPT CARPET

CT CERAMIC TILE

CTV CABLE TELEVISION

CU CUBIC

CUH CABINET UNIT HEATER

CY CUBIC YARD

DBL DOUBLE

DD DESIGN DEVELOPMENT

DEG DEGREE

DEMO DEMOLISH / DEMOLITION

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DH DOUBLE-HUNG

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DIV DIVISION

DN DOWN

DP DESIGN PRESSURE

DR DINING ROOM

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING

DWR DRAWER

(E) EXISTING

E EAST

EA EACH

EF EACH FACE

EJ EXPANSION JOINT

ELEC ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

ENGR ENGINEER

EOS EDGE OF SLAB

EQ EQUAL

EQUIP EQUIPMENT

ES EACH SIDE

ESMT EASEMENT

EST ESTIMATE

EUH ELECTRIC UNIT HEATER

EXCL EXCLUDE(D)

EXH EXHAUST

EXP EXPOSED

EXT EXTERIOR

F FARENHEIT

F.O. FACE OF

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

FCC FIRE COMMAND CENTER

FCR FIRE COMMAND ROOM

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISHED FLOOR

FFE FINISHED FLOOR ELEVATION

FH FIRE HYDRANT

FHA FAIR HOUSING ACT

FIXT FIXTURE

FLG FLOORING

FLR FLOOR

FLSH FLASHING

FLUOR FLUORESCENT

FND FOUNDATION

FRG FURRING

FRP FIBERGLASS REINFORCED PANEL(ING)

FRT FIRE RETARDANT TREATED

FSD FIRE SEPARATION DISTANCE

FT FOOT (FEET)

FTG FOOTING

FURN FURNITURE

GA GAUGE

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GEN GENERATOR

GEO GEOTECH

GFRC GLASS-FIBER REINFORCED CONCRETE

GL GLASS / GLAZING

GLU LAM GLUE-LAMINATED

GR GRADE

GYP GYPSUM

GYP BD GYPSUM BOARD

HB HOSE BIBB

HC HOLLOW CORE

HDR HEADER

HDW HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HOUR

HSKG HOUSEKEEPING

HT HEIGHT

HVAC HEATING, VENTILATION, AIR CONDITIONING

HW HOT WATER

HWY HIGHWAY

IBC INTERNATIONAL BUILDING CODE

ICC INTERNATIONAL CODE COUNCIL

ID INSIDE DIAMETER

IIC INITIAL IMPACT COEFFICIENT

IN INCH(ES)

INCAND INCANDESCENT

INCL INCLUD(ED)

INFO INFORMATION

INSUL INSULATION / INSULATED

INT INTERIOR

JAN JANITOR

JST JOIST

JT JOINT

K KING

KD KNOCKDOWN

KIT KITCHEN

KO KNOCKOUT

KPL KICK PLATE

LA LANDSCAPE

LAB LABORATORY

LAM LAMINATE

LAV LAVATORY

LGMF LIGHT GAUGE METAL FRAMING

LH LEFT HAND

LIQ LIQUID

LKR LOCKER

LNTL LINTEL

LP LIGHTING POLE

LR LIVING ROOM

LT LIGHT

LV LOW VOLTAGE

LVL LAMINATED VENEER LUMBER

LVR LOUVER

M.O. MASONRY OPENING

MACH MACHINE

MAG MAGNETIC

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MED MEDIUM

MEMB MEMBRANE

MEP MECHANICAL, ELECTRICAL, PLUMBING

MEZZ MEZZANINE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MM MILLIMETERS

MTD MOUNT(ED)

MTL METAL

MULL MULLION

MW MICROWAVE

(N) NEW

N NORTH

NAVD88 NORTH AMERICAN VERTICAL DATUM OF 1988

NIC NOT IN CONTRACT

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

O.C. ON CENTER

O.F. OUTSIDE FACE

OA OUTSIDE AIR

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OFD OVERFLOW DRAIN

OFF OFFICE

OFOI OWNER FURNISHED, OWNER INSTALLED

OH OPPOSITE HAND

OHD OVERHEAD DOOR

OLF OCCUPANT LOAD FACTOR

OPNG OPENING

OPP OPPOSITE

OVH OVERHEAD

OZ OUNCE

PAR PARALLEL

PC PRECAST

PERF PERFORATED

PERIM PERIMETER

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLAS PLASTIC

PLBG PLUMBING

PLY PLYWOOD

PNL PANEL

PNT PAINTED

POL POLISHED

PR PAIR

PREFAB PREFABRICATED

PREFIN PREFINISHED

PRIM PRIMARY

PRKG PARKING

PROJ PROJECT

PS PRESTRESSED

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT POST-TENSIONED CONCRETE

PTN PARTITION

PV PHOTOVOLTAIC

PVC POLYVINYL CHLORIDE

Q QUEEN

QT QUART

QTR QUARTER

QTY QUANTITY

R R-VALUE

RAD RADIUS

RB RUBBER BASE

RCL RECYCLE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN / ROAD

RE REFER TO

REC RECESS(ED)

RECPT RECEPTACLE

REF REFRIGERATOR

REINF REINFORCED

REQD REQUIRED

RESIL RESILIENT

REV REVISE / REVISED / REVISION(S)

RF RESILIENT FLOORING

RFG ROOFING

RFI REQUEST FOR INFORMATION

RH RIGHT HAND

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

RR RESTROOM(S)

RTU ROOF TOP UNIT

RW ROOM WIZARD

S SOUTH

SAF SELF-ADHERED FLASHING

SC SOLID CORE

SCHED SCHEDULE

SD SCHEMATIC DESIGN

SECT SECTION

SF SQUARE FEET

SHGC SOLAR HEAT GAIN COEFFICIENT

SHT SHEET

SHTHG SHEATHING

SHWR SHOWER

SIM SIMILAR

SPEC(S) SPECIFICATION(S)

SPKLR SPRINKLER

SPKR SPEAKER

SQ SQUARE

SS SOLID SURFACE

SSTL STAINLESS STEEL

ST STREET

STC SOUND TRANSMISSION COEFFICIENT

STD STANDARD

STE SUITE

STL STEEL

STOR STORAGE

STRUCT STRUCTURE / STRUCTURAL

SURV SURVEY

SUSP SUSPEND(ED)

SYM SYMBOL

SYMM SYMMETRICAL

SYS SYSTEM

T TREAD

T&G TONGUE AND GROOVE

T.O. TOP OF

T.O.C TOP OF CONCRETE/CURB

T.O.S TOP OF STEEL/SLAB

T.O.W TOP OF WALL

TEL TELEPHONE

TELECOM TELECOMMUNICATIONS

TEMP TEMPORARY

THERM THERMAL

THK THICK

TMPD OR (T) TEMPERED

TN TECHNOLOGY

TS TUBE STEEL

TSTAT THERMOSTAT

TV TELEVISION

TYP TYPICAL

U URBAN

UL UNDERWRITER'S LABORATORY

UNO UNLESS NOTED OTHERWISE

USGS UNITED STATES GEOLOGICAL SURVEY

V VOLT

VCT VINYL COMPOSITION TILE

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VOL VOLUME

VWC VINYL WALL COVERING

W WEST

W.O. WHERE OCCURS

W/ WITH

W/D WASHER / DRYER

W/O WITHOUT

WC WALL COVERING

WD WOOD

WF WIDE FLANGE

WIN WINDOW

WRB WEATHER RESISTANT BARRIER

WSCT WAINSCOT

WT WEIGHT

XFMR TRANSFORMER

YD YARD

ZLL ZONE LOT LINE

SHEET

NUMBER SHEET NAME D

E S

IG

N

D E

V E

LO

P

M E

N T

P E

R M

IT

D

R A

W

IN

G S

C O

N S

T

B

ID

D R

A W

IN

G

S

IFC SET

GENERAL

G-000 COVER ● ● ● ●

G-010 PROJECT INFORMATION, ABBREVIATIONS, SHEET INDEX ● ● ● ●

G-100 LL PARKING GARAGE BUILDING CODE PLAN ● ● ●

G-101 LEVEL 1 BUILDING CODE PLAN ● ● ● ●

G-102 LEVEL 2 BUILDING CODE PLAN ● ● ● ●

G-103 BUILDING CODE SUMMARY ● ● ● ●

G-400 ENERGY COMPLIANCE CHECKLIST ● ● ●

G-500 SIGN TYPES ● ● ● ●

G-505 STANDARD MOUNTING HEIGHTS - ANSI 2017 ● ● ● ●

SN-01 SITE SIGN LOCATION PLAN ● ● ●

SN-02 SIGN DESIGN INTENT ● ● ●

CIVIL

C0.0 LEGEND, NOTES AND ABBREVIATIONS ● ● ● ●

C0.1 DEMOLITION PLAN ● ● ● ●

C1.1 CIVIL SITE PLAN ● ● ● ●

CD1.1 SITE DETAILS ● ● ● ●

LANDSCAPE

L1.0 EXISTING LANDSCAPE PLAN ● ● ● ●

L1.1 LANDSCAPE PLAN ● ● ● ●

L2.0 LANDSCAPE NOTES AND DETAILS ● ● ● ●

STRUCTURAL

S-001 GENERAL NOTES & STATEMENT OF SPECIAL INSPECTIONS ● ● ● ●

S-002 ABBREVIATIONS, SYMBOLS KEY, & 3D VIEW ● ● ● ●

S-100 FRAMING PLANS ● ● ● ●

S-501 TYPICAL STEEL DETAILS ● ● ● ●

ARCHITECTURE

AD-100 DEMO LL PARKING GARAGE FLOOR PLAN ● ● ● ●

AD-101 DEMO LEVEL 1 FLOOR PLAN ● ● ● ●

AD-102 DEMO LEVEL 2 FLOOR PLAN ● ● ● ●

AD-130 DEMO LL PARKING GARAGE REFLECTED CEILING PLAN ● ● ● ●

AD-131 DEMO LEVEL 1 REFLECTED CEILING PLAN ● ● ● ●

AD-132 DEMO LEVEL 2 REFLECTED CEILING PLAN ● ● ● ●

A-005 STANDARD PARTITION TYPES ● ● ● ●

A-100 LL PARKING GARAGE FLOOR PLAN ● ● ● ●

A-101 LEVEL 1 FLOOR PLAN ● ● ● ●

A-101.1 LEVEL 1 FLOOR PLAN - DIMENSIONS ● ● ●

A-102 LEVEL 2 FLOOR PLAN ● ● ● ●

A-102.1 LEVEL 2 FLOOR PLAN - DIMENSIONS ● ● ●

A-103 ROOF PLAN ● ● ● ●

A-130 LL PARKING GARAGE RCP ● ● ● ●

A-131 LEVEL 1 RCP ● ● ● ●

A-131.1 LEVEL 1 SYSTEM RCP ● ● ●

A-132 LEVEL 2 RCP ● ● ● ●

A-132.1 LEVEL 2 SYSTEM RCP ● ● ●

A-141 INTERIOR SCHEDULES ● ● ● ●

A-142 INTERIOR EQUIPMENT AND ACCESSORY SCHEDULES ● ● ● ●

A-151 LEVEL 1 FINISH PLAN ● ● ● ●

A-152 LEVEL 2 FINISH PLAN ● ● ● ●

A-161 LEVEL 1 FURNITURE PLAN ● ● ● ●

A-162 LEVEL 2 FURNITURE PLAN ● ● ● ●

A-440 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 RESTROOMS ● ● ● ●

A-441 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 RESTROOMS ● ● ● ●

A-442 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 GENDER NEUTRAL ● ● ● ●

A-443 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 SHOWERS ● ● ● ●

A-444 ENLARGED PLANS AND ELEVATIONS_LEVEL 02 RESTROOMS ● ● ● ●

A-445 ENLARGED PLANS AND ELEVATIONS_LEVEL 02 RESTROOMS ● ● ● ●

A-446 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 WELCOME DESK ● ● ● ●

A-448 ENLARGED PLANS AND ELEVATIONS_FACE TO FACE ROOMS ● ● ● ●

A-449 ENLARGED PLANS AND ELEVATIONS_FACE TO FACE ROOMS ● ● ● ●

A-450 ENLARGED PLANS AND ELEVATIONS_ELEVATORS ● ● ● ●

A-451 ENLARGED PLANS AND ELEVATIONS_ELEVATORS ● ● ● ●

A-452 ENLARGED PLANS AND ELEVATIONS_ELEVATORS ● ● ● ●

A-453 ENLARGED PLANS AND ELEVATIONS ●

A-454 ENLARGED PLANS AND ELEVATIONS ● ● ● ●

A-460 INTERIOR ELEVATIONS ● ● ● ●

A-461 INTERIOR ELEVATIONS ● ● ● ●

A-462 INTERIOR ELEVATIONS ● ● ● ●

A-463 INTERIOR ELEVATIONS ● ●

A-464 INTERIOR ELEVATIONS ● ● ● ●

A-520 ROOF DETAILS ● ● ●

A-550 INTERIOR DETAILS - GENERAL ● ● ● ●

A-560 INTERIOR DETAILS - CEILINGS ● ● ●

A-570 INTERIOR DETAILS - MILLWORK ● ● ●

A-580 INTERIOR DETAILS - TRANSITIONS ● ● ●

A-600 DOOR SCHEDULE & TYPES ● ● ● ●

A-610 DOOR DETAILS ● ● ●

A-900 RENDERINGS - FOR REFERENCE ● ● ● ●

PLUMBING

P-001 PLUMBING LEGEND AND NOTES ● ● ●

P-002 PLUMBING SCHEDULES ● ● ●

PD-100U PLUMBING DEMOLITION PLAN - UNDERGROUND ● ● ●

PD-100 PLUMBING DEMOLITION PLAN - GARAGE LEVEL ● ● ●

PD-101 PLUMBING DEMOLITION PLAN - LEVEL 1 ● ● ●

PD-102 PLUMBING DEMOLITION PLAN - LEVEL 2 ● ● ●

PD-103 PLUMBING DEMOLITION PLAN - ROOF ● ● ●

P-100U PLUMBING PLAN - UNDERGROUND ● ● ●

P-100 PLUMBING PLAN - GARAGE ● ● ●

P-101 PLUMBING PLAN - LEVEL 1 ● ● ●

P-102 PLUMBING PLAN - LEVEL 2 ● ● ●

P-103 PLUMBING PLAN - ENLARGED ● ● ●

P-301 PLUMBING PLAN - ENLARGED ● ●

P-500 PLUMBING DETAILS ● ●

NO DATE DESCRIPTION

SHEET

NUMBER SHEET NAME D

E S

IG

N

D E

V E

LO

P

M E

N T

P E

R M

IT

D

R A

W

IN

G S

C O

N S

T

B

ID

D R

A W

IN

G

S

IFC SET

MECHANICAL

M-001 MECHANICAL LEGEND & NOTES ● ● ●

M-002 MECHANICAL SCHEDULES ● ● ●

M-003 MECHANICAL SCHEDULES ● ● ●

M-004 MECHANICAL SEQUENCE OF OPERATIONS ● ●

MD-100 MECHANICAL DEMOLITION PLAN - GARAGE LEVEL ● ● ●

MD-101 MECHANICAL DEMOLITION PLAN - LEVEL 1 ● ● ●

MD-102 MECHANICAL DEMOLITION PLAN - LEVEL 2 ● ● ●

MD-103 MECHANICAL DEMOLITION PLAN - LEVEL 3 ● ● ●

M-100 MECHANICAL PLAN - GARAGE LEVEL ● ● ●

M-101 MECHANICAL PLAN - LEVEL 1 ● ● ●

M-102 MECHANICAL PLAN - LEVEL 2 ● ● ●

M-103 MECHANICAL PLAN - LEVEL 3 ● ● ●

M-500 MECHANICAL DETAILS ● ●

ELECTRICAL

E-000 ELECTRICAL COVER SHEET ● ● ● ●

E-010 ELECTRICAL SITE PLAN ● ● ● ●

ED-100 ELECTRICAL DEMOLITION POWER PLAN - LL PARKING GARAGE ● ● ● ●

ED-101 ELECTRICAL DEMOLITION POWER PLAN - LEVEL 1 ● ● ● ●

ED-102 ELECTRICAL DEMOLITION POWER PLAN - LEVEL 2 ● ● ● ●

ED-200 ELECTRICAL DEMOLITION LIGHTING PLAN - LL PARKING GARAGE ● ● ● ●

ED-201 ELECTRICAL DEMOLITION LIGHTING PLAN - LEVEL 1 ● ● ● ●

ED-202 ELECTRICAL DEMOLITION LIGHTING PLAN - LEVEL 2 ● ● ● ●

E-100 ELECTRICAL POWER PLAN - LL PARKING GARAGE ● ● ● ●

E-101 ELECTRICAL POWER PLAN - LEVEL 1 ● ● ● ●

E-102 ELECTRICAL POWER PLAN - LEVEL 2 ● ● ● ●

E-103 ELECTRICAL POWER PLAN - ROOF ● ● ● ●

E-200 ELECTRICAL LIGHTING PLAN - LL PARKING GARAGE ● ● ● ●

E-201 ELECTRICAL LIGHTING PLAN - LEVEL 1 ● ● ● ●

E-202 ELECTRICAL LIGHTING PLAN - LEVEL 2 ● ● ● ●

E-600 ELECTRICAL EXISTING ONE-LINE DIAGRAM ● ● ● ●

E-601 ELECTRICAL NEW ONE-LINE DIAGRAM ● ● ● ●

E-700 ELECTRICAL PANEL SCHEDULES AND DETAILS ● ● ● ●

E-710 ELECTRICAL PANEL SCHEDULES ● ● ● ●

E-711 ELECTRICAL PANEL SCHEDULES ● ● ● ●

E-712 ELECTRICAL PANEL SCHEDULES ● ● ● ●

E-713 ELECTRICAL PANEL SCHEDULES ● ● ● ●

E-800 ELECTRICAL LIGHTING SCHEDULES ● ● ● ●

E-801 ELECTRICAL LIGHTING CONTROLS SCHEDULES ● ● ● ●

E-900 ELECTRICAL LIGHTING COMPLIANCE ● ● ● ●

03.10.202603.10.2026

UP

UP

DO

W

N

UP

Stair #2

Stair #1

Lobby

Equip.

Elevator

Elevator Stair #3

Storage

Parking Bicycle

Stair #5

Parking

Valve Room

Equipment Electrical Protection

Fire

UP

8.0' WIDE PSCO EASEMENT

REC. NO. 21812927

WATERLINE EASEMENT

REC. NO. 2201480

FOUND 1 1/2" ALUMINUM

COLLAR IN CONCRETE "DB

CO PLS 23529"

UTILITY EASEMENT TO THE CITY OF BOULDER

REC. NO. 2096393 & NO. 2155900

54 PAINTED GARAGE

SPACES

2 HC SPACES

5 SPACES

SIDEWALK EASEMENT

REC. NO. 2096392 & REC. NO. 2155901

PARCEL A

EXCEPTED PORTION

REC.

M U

LC

H

D

IR

T

MULCH

N89°47'18"E 380.80' (C)

EAST 380.8' (TC)9

.9

N89°47'18"E 338.82' (C)

CHASE

GARAGE EXIT

GARAGE ENTRANCE

C O N C

B

LO

C K

S T A

IR

W E

LL

CHASE

CONC.

WALL

FOUND

8.0' WIDE PSCO EASEMENT

REC. NO. 21812927

WATERLINE EASEMENT

REC. NO. 2201480

FOUND 1 1/2" ALUMINUM

COLLAR IN CONCRETE "DB

CO PLS 23529"

UTILITY EASEMENT TO THE CITY OF BOULDER

REC. NO. 2096393 & NO. 2155900

54 PAINTED GARAGE

SPACES

2 HC SPACES

5 SPACES

SIDEWALK EASEMENT

REC. NO. 2096392 & REC. NO. 2155901

PARCEL A

EXCEPTED PORTION

REC.

M U

LC

H

D

IR

T

MULCH

N89°47'18"E 380.80' (C)

EAST 380.8' (TC)9

.9

N89°47'18"E 338.82' (C)

CHASE

GARAGE EXIT

GARAGE ENTRANCE

C O N C

B

LO

C K

S T A

IR

W E

LL

CHASE

CONC.

WALL

FOUND

ASSEMBLY RATING

NON-RATED ASSEMBLY

1 HOUR ASSEMBLY

2 HOUR ASSEMBLY

3 HOUR ASSEMBLY

4 HOUR ASSEMBLY

ASSEMBLY TYPE

BW BEARING WALL (IBC SECTION 704)

FW FIRE WALL (IBC SECTION 706)

FB FIRE BARRIER (IBC SECTION 707)

FP FIRE PARTITION (IBC SECTION 708)

SB SMOKE BARRIER (IBC SECTION 709)

SP SMOKE PARTITION (IBC SECTION 710)

SE SHAFT ENCLOSURE (IBC SECTION 713)

OCCUPANT LOAD

EGRESS DIRECTION

FIRE EXTINGUISHER

FE

FDC

FACP

KB KNOX BOX

EXIT ST-N

203 OCCUPANTS

0.2"/OCC = 3'-4" REQ'D

3'-8" PROVIDED

EXIT STAIR NAME OR

DOOR NUMBER

NUMBER OF OCCUPANTS

REQ'D EGRESS WIDTH

CALCULATIONS

PROVIDED EGRESS WIDTH

BIKE STORAGE

300 SF GROSS

ACCESSORY STORAGE

R-2

300 SF/OCC

2 OCCUPANTS

1 EXITS REQ'D

ROOM NAME

AREA & TYPE (GROSS OR NET)

FUNCTION OF SPACE

(TABLE 1004.1.2)

OCCUPANT LOAD FACTOR

TOTAL OCCUPANTS

EXITS REQUIRED

OCCUPANCY GROUP

GARAGE PATH

220'-10"

LOBBY PATH

30'-5"

TRAVEL DISTANCE PATH NAME

ACTUAL TRAVEL DISTANCE,

SEE SCHEDULE FOR

ALLOWABLE

EGRESS PATH

COMMON PATH OF TRAVEL NAME

ACTUAL TRAVEL DISTANCE,

SEE SCHEDULE FOR

ALLOWABLE

CONVERGENT OCCUPANT LOAD

EGRESS DIRECTION

FIRE DEPARTMENT

CONNECTION

FIRE ALARM

CONTROL PANEL

ACCESSIBLE PATH OF TRAVEL

EGRESS PATH

CODE SHEET GRAPHICS LEGEND

EXIT SIGN

1. BUILDING SHALL BE SPRINKLERED THROUGHOUT IN ACCORDANCE WITH IBC CHAPTER 9 AND

NFPA (13). PROVIDE DRY SPRINKLER SYSTEM WHERE APPROPRIATE AND AT ALL UNCONDITIONED

LOCATIONS

2. AREA OF REFUGE IS NOT REQUIRED PER 1009.3.3 EXCEPTION NO.2

3. ELEVATOR TO COMPLY WITH STRETCHER DIMENSIONS AS REQUIRED BY IBC CHAPTER 30

4. SEE A-000 SERIES SHEETS FOR LISTED ASSEMBLIES FOR FLOOR/CEILINGS, ROOF/CEILINGS, EXTERIOR WALLS, AND PARTITIONS. LISTED FIRE-RESISTIVE ASSEMBLIES MAY BE SUBSTITUTED

WITH APPROVAL OF AUTHORITY HAVING JURISDICTION AND ARCHITECT

5. SEE DOOR SCHEDULE, SHEET A-600 FOR DOOR RATINGS. ALL RATED DOORS TO COMPLY WITH

IBC 716

6. ALL PENETRATIONS THROUGH FLOORS AND RATED WALLS TO BE FIRESTOPPED IN ACCORDANCE

WITH IBC CHAPTER 7

7. THE GC IS TO COORDINATE FIRE DEPARTMENT CONNECTION (FDC) LOCATION WITH AUTHORITY

HAVING JURISDICTION AND ARCHITECT

8. THE GC IS TO COORDINATE KNOX BOX LOCATION WITH FIRE DEPARTMENT AND ARCHITECT

CODE NOTES

2 7 10

L

8 954

B

J

C

K

1 3 11

H

G

D

E

F

A

M

19,620 SF

PARKING GARAGE

PARKING GARAGE

99 OCCUPANTS

2 EXITS REQ'D

S-2

200 SF/OCC

2'-9 5/8" PROVIDED

EXIT STAIR DOOR 5

10 OCCUPANTS

0.2"/OCC 2" REQ'D

2'-9 5/8" PROVIDED

EXIT STAIR DOOR 5.1

144 OCCUPANTS

0.2"/OCC 2'-4 3/4" REQ'D

2'-9 5/8" PROVIDED

EXIT STAIR 1.1

138 OCCUPANTS

0.2"/OCC 2'-3 5/8" REQ'D

12.02

PROJECT NUMBER:

DATE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

REVISIONS:

/1

/2

:5

:1

P

M A u to d e s k D o c s /1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

/1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

A

.r v t BO

U

LD

ER

C

O U

N

TY

C O

M M

U N

IT

Y

H U

B

8t h

St

Bo ul de r, Co

125020.00

20260309

100% IFC

LL PARKING GARAGE

BUILDING CODE PLAN

G-100

PROJECT FLAGNOTES

12.02 EXISTING 14 LONG TERM BIKE RACKS TO REMAIN

OCCUPANT LOAD CALCULATIONS - BY LEVEL - AREAS

OCCUPANCY OCCUPANT

LOAD

FACTOR

OCCUPANT

LOAD AREATABLE 1004.1.2 - USE DESCRIPTION

LL PARKING GARAGE

Parking Garages 200 99 19,620 SF

99 19,620 SF

GRAND TOTAL 99 19,620 SF

OCC GROUPS

S-2 19,620 SF

GRAND TOTAL 19,620 SF

TRUE

NORTH

0' 4' 8' 16' 32' 1/8" = 1'-0"

LL PARKING GARAGE- EGRESS CODE PLAN

NO DATE DESCRIPTION

WATERLINE EASEMENT

REC. NO. 2201480

M U

LC

H

D

IR

T

MULCH

N89°47'18"E 380.80' (C)

EAST 380.8' (TC)9

.9

N89°47'18"E 338.82' (C)

FE

FE

FE

F E

FE

F E

F E

FE

14 14

RK/36NRK/36N

T K

B D

/4

T

K B

D /4

TKBD16/48 TKBD16/48

TKBD16/36

TKBD16/42

TKBD16/36

TKBD16/42

TKBD16/30

F D

F /B

/4

F

D F

/B /4

FDF/B13/42FDF/B13/36

FDF/B13/48FDF/B13/48

FDF/B13/36

FDF/B13/42FDF/B13/42

S H

F /B

/4

SHF/B13/48

SHF/B13/36

SHF/B13/36 S

H

F /B

/4

SHF/B13/48

SHF/B42 SHF/B42

FDF/B13/42

COH

COH COH

COH

COH

COH

COH

COH

COH

COH

C O H

BROCHURE

STORAGE

OPTIONS - IN

ALL FACE TO

FACE ROOMS

BROCHURE STORAGE

OPTIONS - IN ALL FACE TO

FACE ROOMS

C H

-4

CH-4CH-4

C H

-4

CH-4CH-4CH-4

C H

-4

C H

-4

CH-4CH-4

CH-4

.9

31.78"

32.62"

38"

.6

51"

56"

-4

-7

40"

59.04"

.6

27.47" 49.80"

41"

.1

53"

.5

"6 .5

.5

59.09"

44.42"

54.78" 60.26"

46.25"

52.33"

64.28"

22.72"

.6

.1

54.39"

.6

ASSEMBLY RATING

NON-RATED ASSEMBLY

1 HOUR ASSEMBLY

2 HOUR ASSEMBLY

3 HOUR ASSEMBLY

4 HOUR ASSEMBLY

ASSEMBLY TYPE

BW BEARING WALL (IBC SECTION 704)

FW FIRE WALL (IBC SECTION 706)

FB FIRE BARRIER (IBC SECTION 707)

FP FIRE PARTITION (IBC SECTION 708)

SB SMOKE BARRIER (IBC SECTION 709)

SP SMOKE PARTITION (IBC SECTION 710)

SE SHAFT ENCLOSURE (IBC SECTION 713)

OCCUPANT LOAD

EGRESS DIRECTION

FIRE EXTINGUISHER

FE

FDC

FACP

KB KNOX BOX

EXIT ST-N

203 OCCUPANTS

0.2"/OCC = 3'-4" REQ'D

3'-8" PROVIDED

EXIT STAIR NAME OR

DOOR NUMBER

NUMBER OF OCCUPANTS

REQ'D EGRESS WIDTH

CALCULATIONS

PROVIDED EGRESS WIDTH

BIKE STORAGE

300 SF GROSS

ACCESSORY STORAGE

R-2

300 SF/OCC

2 OCCUPANTS

1 EXITS REQ'D

ROOM NAME

AREA & TYPE (GROSS OR NET)

FUNCTION OF SPACE

(TABLE 1004.1.2)

OCCUPANT LOAD FACTOR

TOTAL OCCUPANTS

EXITS REQUIRED

OCCUPANCY GROUP

GARAGE PATH

220'-10"

LOBBY PATH

30'-5"

TRAVEL DISTANCE PATH NAME

ACTUAL TRAVEL DISTANCE,

SEE SCHEDULE FOR

ALLOWABLE

EGRESS PATH

COMMON PATH OF TRAVEL NAME

ACTUAL TRAVEL DISTANCE,

SEE SCHEDULE FOR

ALLOWABLE

CONVERGENT OCCUPANT LOAD

EGRESS DIRECTION

FIRE DEPARTMENT

CONNECTION

FIRE ALARM

CONTROL PANEL

ACCESSIBLE PATH OF TRAVEL

EGRESS PATH

CODE SHEET GRAPHICS LEGEND

EXIT SIGN

CHAPTER 10 FUNCTION OF SPACE

ACCESSORY STORAGE

ASSEMBLY AREA

BUSINESS AREA

EDUCATIONAL

EXERCISE ROOM

7 10

L

8 954

B

J

C

K

1,216 SF

EDUCATIONAL

TRAINING

61 OCCUPANTS

2 EXITS REQ'D

A-3

20 SF/OCC

582 SF

EXERCISE ROOM

FITNESS

12 OCCUPANTS

1 EXITS REQ'D

A-3

50 SF/OCC

480 SF

ASSEMBLY AREA

LARGE

CONFERENCE

32 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

657 SF

ASSEMBLY AREA

BREAKROOM

44 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

3,260 SF

BUSINESS AREA

OPEN OFFICE - AREA

A

22 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

595 SF

EDUCATIONAL

WORKFORCE LAB

30 OCCUPANTS

1 EXITS REQ'D

B

20 SF/OCC

404 SF

BUSINESS AREA

PH/VR COUNTER

3 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

131 SF

ASSEMBLY AREA

HOSPITALITY

9 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

351 SF

ASSEMBLY AREA

WAITING

24 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

190 SF

BUSINESS AREA

CEDM

2 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

286 SF

ASSEMBLY AREA

ISSUANCE WAITING

20 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

1 3 11

H

G

D

E

F

A

170 SF

ACCESSORY STORAGE

STORAGE

1 OCCUPANTS

1 EXITS REQ'D

S-2

300 SF/OCC

100 SF

ACCESSORY STORAGE

WF STORAGE

1 OCCUPANTS

1 EXITS REQ'D

S-2

300 SF/OCC

92 SF

ASSEMBLY AREA

CHILDRENS

WAITIING

7 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

74 SF

ACCESSORY STORAGE

JC

1 OCCUPANTS

1 EXITS REQ'D

S-2

300 SF/OCC

FURNITURE STORAGE

CDEM EMER MGMT

TRAINING/BREAKOUT FACE TO FACE

SERVER ROOM

LOBBY

LARGE CONFERENCE/

WORKFORCE LAB

FACE TO FACE FACE TO FACE FACE TO FACE FACE TO FACE FACE TO FACE

W. RESTROOM

SECURITY/MAIL ROOM

HUDDLE ROOM

1,024 SF

BUSINESS AREA

OPEN OFFICE

7 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

FACE TO FACE

ELECTRICAL ROOM

STAFF SHOWER/RR

ISSUANCE AND SAFE

V R

S T

O R

ALL GENDERED

AAA / VETERANSAAA / VETERANS

TRAINING ROOM B

TRAINING ROOM A

CDEM / EMER MGMT

FACE TO FACE

FACE TO FACE

FACE TO FACE

FACE TO FACE

WIC / IMM. EXAM RM

WIC / IMM. EXAM RM

M. RESTROOM

STAIRS 2

STAIRS 3

LOBBY

PUB HEALTH VITAL RECORDS

319 SF

BUSINESS AREA

ISSUANCE/SAFE

3 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

325 SF

BUSINESS AREA

AAA / VETERANS

3 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

791 SF

BUSINESS AREA

FACE TO FACE

6 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

679 SF

BUSINESS AREA

RECEPTION

5 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

916 SF

BUSINESS AREA

OFFICE / FACE TO

FACE

7 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

22 79

M

R

EQ

U

IR

ED

SEPAR

ATIO

N

49'-9" /3 = 16'-6"

P R

O V

ID

E

D S

E P

A R

A T

IO

N

6' -1

0"

433 SF

BUSINESS AREA

BENEFITS

3 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

534 SF

BUSINESS AREA

LOBBY / OFFICE

4 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

2'-9 5/8" PROVIDED

EXIT STAIR DOOR 5.2

134 OCCUPANTS

0.2"/OCC 2'-2 3/4" REQ'D

193 SF

STAIR 5

EXIT 101A

33 OCCUPANTS

0.2"/OCC 6 5/8" REQ'D

6'-0" PROVIDED

2'-9 5/8" PROVIDED

EXIT STAIR DOOR1.2

142 OCCUPANTS

0.2"/OCC 2'-4 3/8" REQ'D

160 SF

STAIR 1

111 SF

BUSINESS AREA

WELLNESS RM

1 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

70 SF

ACCESSORY STORAGE

ENV HLTH REF STRG

1 OCCUPANTS

1 EXITS REQ'D

S-2

300 SF/OCC

TRAVEL

DISTANCE 1

TRAVEL

DISTANCE 2

COMMON PATH

OF TRAVEL 1

C O

M M

O N

P A

T H

O F

T R

A V

E L

EXIT STAIR 5

134 OCCUPANTS

0.2"/OCC MIN 3'-8" REQ'D

4'-1" PROVIDED

TRAVEL

DISTANCE 3

C O

M M

O N

P A

T H

O F

T R

A V

E L

COMMON PATH

OF TRAVEL 4

TRAVEL

DISTANCE 4

EXISTING STAIR

IS NOT CONSIDERED

A PATH OF EGRESS

STAIR TO INCLUDE

ACCESS CONTROL

D O

W N

U P

D O

W N

U P

EXIT STAIR 1

142 OCCUPANTS

0.3"/OCC MIN 3'-8" REQ'D

4'-1" PROVIDED

27.02

FACILITIES/ELEC

CLOSET

TELE

27.03

27.04

ACCESSIBLE PATH

1. BUILDING SHALL BE SPRINKLERED THROUGHOUT IN ACCORDANCE WITH IBC CHAPTER 9 AND

NFPA (13). PROVIDE DRY SPRINKLER SYSTEM WHERE APPROPRIATE AND AT ALL UNCONDITIONED

LOCATIONS

2. AREA OF REFUGE IS NOT REQUIRED PER 1009.3.3 EXCEPTION NO.2

3. ELEVATOR TO COMPLY WITH STRETCHER DIMENSIONS AS REQUIRED BY IBC CHAPTER 30

4. SEE A-000 SERIES SHEETS FOR LISTED ASSEMBLIES FOR FLOOR/CEILINGS, ROOF/CEILINGS, EXTERIOR WALLS, AND PARTITIONS. LISTED FIRE-RESISTIVE ASSEMBLIES MAY BE SUBSTITUTED

WITH APPROVAL OF AUTHORITY HAVING JURISDICTION AND ARCHITECT

5. SEE DOOR SCHEDULE, SHEET A-600 FOR DOOR RATINGS. ALL RATED DOORS TO COMPLY WITH

IBC 716

6. ALL PENETRATIONS THROUGH FLOORS AND RATED WALLS TO BE FIRESTOPPED IN ACCORDANCE

WITH IBC CHAPTER 7

7. THE GC IS TO COORDINATE FIRE DEPARTMENT CONNECTION (FDC) LOCATION WITH AUTHORITY

HAVING JURISDICTION AND ARCHITECT

8. THE GC IS TO COORDINATE KNOX BOX LOCATION WITH FIRE DEPARTMENT AND ARCHITECT

CODE NOTES

PROJECT NUMBER:

DATE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

REVISIONS:

/1

/2

:5

:2

P

M A u to d e s k D o c s /1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

/1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

A

.r v t BO

U

LD

ER

C

O U

N

TY

C O

M M

U N

IT

Y

H U

B

8t h

St

Bo ul de r, Co

125020.00

20260309

100% IFC

LEVEL 1 BUILDING CODE

PLAN

G-1011/8" = 1'-0"

LEVEL 1 - EGRESS CODE PLAN

OCCUPANT LOAD CALCULATIONS - BY LEVEL - AREAS

OCCUPANCY OCCUPANT

LOAD

FACTOR

OCCUPANT

LOAD AREATABLE 1004.1.2 - USE DESCRIPTION

LEVEL 1

Accessory storage areas, mechanical equipment room 300 1 70 SF

Accessory storage areas, mechanical equipment room 300 1 74 SF

Accessory storage areas, mechanical equipment room 300 1 170 SF

Accessory storage areas, mechanical equipment room 300 1 100 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 44 657 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 7 92 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 9 131 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 20 286 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 32 480 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 24 351 SF

Business Areas -150 150 3 325 SF

Business Areas -150 150 3 433 SF

Business Areas -150 150 2 190 SF

Business Areas -150 150 26 3,824 SF

Business Areas -150 150 6 791 SF

Business Areas -150 150 3 319 SF

Business Areas -150 150 4 534 SF

Business Areas -150 150 7 916 SF

Business Areas -150 150 7 1,024 SF

Business Areas -150 150 22 3,260 SF

Business Areas -150 150 3 404 SF

Business Areas -150 150 5 679 SF

Business Areas -150 150 11 1,317 SF

Business Areas -150 150 1 111 SF

Educational - Classroom area - Net Area 20 61 1,216 SF

Educational - Classroom area - Net Area 20 30 595 SF

Exercise Rooms 50 12 582 SF

346 18,931 SF

GRAND TOTAL 346 18,931 SF

OCC GROUPS

A-3 1,798 SF

B 16,718 SF

S-2 414 SF

GRAND TOTAL 18,931 SF

TRUE

NORTH

0' 4' 8' 16' 32'

EGRESS PATH LENGTH - FAMILY

PATH SEGMENT NAME PATH SEGMENT LENGTH

MAX DISTANCE

ALLOWED

COMMON PATH OF EGRESS

COMMON PATH OF TRAVEL 1 73' - 3" 100'-0"

COMMON PATH OF TRAVEL 2 57' - 6" 100'-0"

COMMON PATH OF TRAVEL 3 37' - 6" 100'-0"

COMMON PATH OF TRAVEL 4 58' - 11" 100'-0"

TRAVEL DISTANCE

TRAVEL DISTANCE 1 133' - 0" 300'-0"

TRAVEL DISTANCE 2 109' - 9" 300'-0"

TRAVEL DISTANCE 3 97' - 4" 300'-0"

TRAVEL DISTANCE 4 129' - 2" 300'-0"

PROJECT FLAGNOTES

27.02 EXISTING KNOX BOX LOCATION TO REMAIN.

27.03 EXISTING FACP LOCATION. DEVICES AND CONTROLS TO REMAIN.

27.04 EXISTING FACP CONTROLS TO REMAIN

DNF

E

FE FE

FE

F E

FE

F E

S E

T L

S T

SETL3ST

SETL3ST

06E

06E

E

E

J

J

E

60"

06E

06E

06E

06E 06E

06E

J

J

J

J

J

06E

J

E

E

J

J

06E

E

E

J

E

E

J

A-4491

A-463

15.67"

2'-10"

44.65"

55.30"

39.08"

.4

13'-7"

51.77"

11'

60"

65.91"

50.51"

10'-11"

5'-2"

13'-6"

120"

.3

.2

.5

43"

.5

62.91"

10'-5"

.9

23'-3"

85"

2'-1"

63.87"

42.00"

47.06"

47"

10'-8"

2'-4"

.0

52.40"

27'-9"

.5

58.88"

10'-9"10'-6"

.2

24'-11"

0'-10"

54.24"

.0

.8

47.06"

60.12"

22'-3"

62.90"

.7

37.69"

54.05" 48.51"

.9

50.53"

65.33"

54.90"

26.52"

.0

ASSEMBLY RATING

NON-RATED ASSEMBLY

1 HOUR ASSEMBLY

2 HOUR ASSEMBLY

3 HOUR ASSEMBLY

4 HOUR ASSEMBLY

ASSEMBLY TYPE

BW BEARING WALL (IBC SECTION 704)

FW FIRE WALL (IBC SECTION 706)

FB FIRE BARRIER (IBC SECTION 707)

FP FIRE PARTITION (IBC SECTION 708)

SB SMOKE BARRIER (IBC SECTION 709)

SP SMOKE PARTITION (IBC SECTION 710)

SE SHAFT ENCLOSURE (IBC SECTION 713)

OCCUPANT LOAD

EGRESS DIRECTION

FIRE EXTINGUISHER

FE

FDC

FACP

KB KNOX BOX

EXIT ST-N

203 OCCUPANTS

0.2"/OCC = 3'-4" REQ'D

3'-8" PROVIDED

EXIT STAIR NAME OR

DOOR NUMBER

NUMBER OF OCCUPANTS

REQ'D EGRESS WIDTH

CALCULATIONS

PROVIDED EGRESS WIDTH

BIKE STORAGE

300 SF GROSS

ACCESSORY STORAGE

R-2

300 SF/OCC

2 OCCUPANTS

1 EXITS REQ'D

ROOM NAME

AREA & TYPE (GROSS OR NET)

FUNCTION OF SPACE

(TABLE 1004.1.2)

OCCUPANT LOAD FACTOR

TOTAL OCCUPANTS

EXITS REQUIRED

OCCUPANCY GROUP

GARAGE PATH

220'-10"

LOBBY PATH

30'-5"

TRAVEL DISTANCE PATH NAME

ACTUAL TRAVEL DISTANCE,

SEE SCHEDULE FOR

ALLOWABLE

EGRESS PATH

COMMON PATH OF TRAVEL NAME

ACTUAL TRAVEL DISTANCE,

SEE SCHEDULE FOR

ALLOWABLE

CONVERGENT OCCUPANT LOAD

EGRESS DIRECTION

FIRE DEPARTMENT

CONNECTION

FIRE ALARM

CONTROL PANEL

ACCESSIBLE PATH OF TRAVEL

EGRESS PATH

CODE SHEET GRAPHICS LEGEND

EXIT SIGN

1. BUILDING SHALL BE SPRINKLERED THROUGHOUT IN ACCORDANCE WITH IBC CHAPTER 9 AND

NFPA (13). PROVIDE DRY SPRINKLER SYSTEM WHERE APPROPRIATE AND AT ALL UNCONDITIONED

LOCATIONS

2. AREA OF REFUGE IS NOT REQUIRED PER 1009.3.3 EXCEPTION NO.2

3. ELEVATOR TO COMPLY WITH STRETCHER DIMENSIONS AS REQUIRED BY IBC CHAPTER 30

4. SEE A-000 SERIES SHEETS FOR LISTED ASSEMBLIES FOR FLOOR/CEILINGS, ROOF/CEILINGS, EXTERIOR WALLS, AND PARTITIONS. LISTED FIRE-RESISTIVE ASSEMBLIES MAY BE SUBSTITUTED

WITH APPROVAL OF AUTHORITY HAVING JURISDICTION AND ARCHITECT

5. SEE DOOR SCHEDULE, SHEET A-600 FOR DOOR RATINGS. ALL RATED DOORS TO COMPLY WITH

IBC 716

6. ALL PENETRATIONS THROUGH FLOORS AND RATED WALLS TO BE FIRESTOPPED IN ACCORDANCE

WITH IBC CHAPTER 7

7. THE GC IS TO COORDINATE FIRE DEPARTMENT CONNECTION (FDC) LOCATION WITH AUTHORITY

HAVING JURISDICTION AND ARCHITECT

8. THE GC IS TO COORDINATE KNOX BOX LOCATION WITH FIRE DEPARTMENT AND ARCHITECT

CODE NOTES

2 7 10

L

8 954

B

J

C

K

CHAPTER 10 FUNCTION OF SPACE

ACCESSORY STORAGE

ASSEMBLY AREA

BUSINESS AREA

1 3 11

H

G

D

E

F

A

202 SF

ASSEMBLY AREA

CONF. RM

14 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

163 SF

ASSEMBLY AREA

CONF. RM

11 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

4,943 SF

BUSINESS AREA

OFFICE

33 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

200 SF

ASSEMBLY AREA

CONF. RM

14 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

377 SF

ASSEMBLY AREA

TRAINING RM

26 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

750 SF

ACCESSORY STORAGE

STORAGE

3 OCCUPANTS

1 EXITS REQ'D

S-2

300 SF/OCC

4,683 SF

BUSINESS AREA

OFFICE

32 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

394 SF

BUSINESS AREA

PRINT / COFFEE /

OPEN WK

3 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

493 SF

ACCESSORY STORAGE

STORAGE

2 OCCUPANTS

1 EXITS REQ'D

S-2

300 SF/OCC

202 SF

ASSEMBLY AREA

CONF. RM

14 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

212 SF

ASSEMBLY AREA

CONFERENCE

15 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

189 SF

ASSEMBLY AREA

PATIO

13 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

226 SF

ASSEMBLY AREA

PATIO

16 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

232 SF

ASSEMBLY AREA

PATIO

16 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

254 SF

ASSEMBLY AREA

PATIO

17 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

316 SF

ASSEMBLY AREA

PATIO

22 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

DHS STORAGE

CS OFFSITE EVENT AND

ADMIN STORAGE

IT STORAGE

DHS STORAGE

IT HELP DESKFACILITIES STORAGEFOCUS

BCPH/WIC/NFP OPEN

STORAGE

HARM REDUCTION

STORAGE

ENVIRONMENTAL

HEALTH STORAGE

EMER MGMT STORAGE

2,333 SF

BUSINESS AREA

OFFICE

16 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

631 SF

BUSINESS AREA

OPEN COLLAB

5 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

PUBLIC HEALTH

STORAGE

DIRECTOR OFFICE

DIRECTOR OFFICE DIRECTOR OFFICE

DIRECTOR OFFICE

CS AAA AGING

STORAGE

SERVER

OPEN WORK

M. RESTROOM

W. RESTROOM

TELE

JAN/ROOF

M

60' - 10"

MAX: 100

COMMON PATH OF TRAVEL 2B

160' - 7"

MAX: 300

TRAVEL DISTANCE 2A

149' - 9"

MAX: 300

TRAVEL DISTANCE 2B

M A

X : 1

C O

M M

O N

P A

T H

O F

T R

A V

E L

2A

0" M

A X

: 1

C O

M M

O N

P A

T H

O F

T R

A V

E L

2C

2'-9 5/8" PROVIDED

EXIT STAIR DOOR 1.3

117 OCCUPANTS

0.2"/OCC 1'-11 3/8" REQ'D

STAIR 5

STAIR 1

001.3

S T

A

IR

2'-9 5/8" PROVIDED

EXIT STAIR DOOR 5.3

167 OCCUPANTS

0.2"/OCC 2'-9 3/8" REQ'D

80 SF

BUSINESS AREA

WELLNESS

1 OCCUPANTS

1 EXITS REQ'D

B

150 SF/OCC

138 SF

ASSEMBLY AREA

OPEN MEETING

10 OCCUPANTS

1 EXITS REQ'D

B

15 SF/OCC

EXISTING STAIR

IS NOT CONSIDERED

A PATH OF EGRESS

STAIR HAS ACCESS

CONTROL

PROJECT NUMBER:

DATE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

REVISIONS:

/1

/2

:5

:2

P

M A u to d e s k D o c s /1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

/1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

A

.r v t BO

U

LD

ER

C

O U

N

TY

C O

M M

U N

IT

Y

H U

B

8t h

St

Bo ul de r, Co

125020.00

20260309

100% IFC

LEVEL 2 BUILDING CODE

PLAN

G-102

PROJECT FLAGNOTES

TRAVEL DISTANCE

PATH NAME ACTUAL DISTANCE MAX DISTANCE ALLOWED

LEVEL 2

TRAVEL DISTANCE 2A 160'-7" 300

TRAVEL DISTANCE 2B 149'-9" 300

COMMON PATH OF TRAVEL

PATH NAME ACTUAL DISTANCE MAX DISTANCE ALLOWED

LEVEL 2

COMMON PATH OF TRAVEL 2A 59'-11" 100

COMMON PATH OF TRAVEL 2B 60'-10" 100

COMMON PATH OF TRAVEL 2C 59'-0" 100

OCCUPANT LOAD CALCULATIONS - BY LEVEL - AREAS

OCCUPANCY OCCUPANT

LOAD

FACTOR

OCCUPANT

LOAD AREATABLE 1004.1.2 - USE DESCRIPTION

LEVEL 2

Accessory storage areas, mechanical equipment room 300 5 1,243 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 53 767 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 15 212 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 10 138 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 84 1,216 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 26 377 SF

Business Areas -150 150 13 1,604 SF

Business Areas -150 150 81 11,959 SF

Business Areas -150 150 5 631 SF

Business Areas -150 150 3 394 SF

Business Areas -150 150 5 643 SF

Business Areas -150 150 1 80 SF

301 19,263 SF

GRAND TOTAL 301 19,263 SF

OCC GROUPS

B 18,021 SF

S-2 1,243 SF

GRAND TOTAL 19,263 SF

TRUE

NORTH

0' 4' 8' 16' 32' 1/8" = 1'-0"

LEVEL 2-EGRESS CODE PLAN

PROJECT INFORMATION

APPLICABLE CODES:

2024 INTERNATIONAL BUILDING CODE (IBC)

2024 INTERNATIONAL FIRE CODE (IFC)

2024 INTERNATIONAL MECHANICAL CODE (IMC)

2024 INTERNATIONAL PLUMBING CODE (IPC)

2024 INTERNATIONAL FUEL AND GAS CODE (IFGC)

2024 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)

2017 ICC/ANSI A117.1, 2017

2023 NATIONAL ELECTRICAL CODE (NEC)

LOCAL AMENDMENTS

ZONING DESIGNATION: BC-2

FIRE SUPPRESSION: FULLY SPRINKLERED PER NFPA 13

PROJECT DESCRIPTION:

39,560 SF, 2 STORY NON-RESIDENTIAL BUILDING, OFFICE TENATE IMPROVEMENT, ROOF

REPLACEMENT. WORK TO EXCEED 50% OF BUILDING AREA.

USE AND OCCUPANCY CLASSIFICATION

MIXED USE NON SEPARATED OCCUPANCIES PER 508.3:

A-3 (ASSEMBLY) MOST RESTRICTIVE

B (BUSINESS)

S-2 (LOW HAZARD STORAGE)

BUILDING HEIGHT AND AREA

CONSTRUCTION TYPE(S): II B

FIRE RESISTANCE REQUIREMENTS

CONSTRUCTION TYPE: TYPE X

PRIMARY STRUCTURAL FRAME: 0

EXTERIOR BEARING WALLS*: 0

INTERIOR BEARING WALLS: 0

INTERIOR NON-BEARING WALLS: 0

FLOOR CONSTRUCTION: 0

ROOF CONSTRUCTION: 0

EXTERIOR NON-BEARING WALLS* BASED ON FIRE SEPARATION DISTANCE (FSD)

FSD < 5': 1

5' < FSD < 10': 1

10' < FSD < 30': 1

FSD > 30': 0

* EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE LESS THAN OR EQUAL TO 10' SHALL BE

RATED FOR EXPOSURE FROM BOTH SIDES.

CONSTRUCTION TYPE MATERIAL REQUIREMENTS:

NON RATED PER TYPE IIB:

ALLOWABLE AREA OF UNPROTECTED OPENINGS BASED ON FIRE SEPARATION DISTANCE:

0' - 3': NOT PERMITTED

3' - 5': 15% 5' - 10': 25% 10' - 15': 45% 15' - 20': 75%

> 20': NO LIMIT

EXIT REQUIREMENTS

EXIT WIDTH:

STAIRS: 0.3" PER OCCUPANT

OTHER COMPONENTS: 0.2 PER OCCUPANT

EXIT ACCESS TRAVEL DISTANCE (MAXIMUM LENGTH):

A-3: 250' B: 300' S-2: 400'

COMMON PATH OF EGRESS TRAVEL (MAXIMUM LENGTH):

A-3: 75' B: 100' S-2: 100'

FINISH CLASSIFICATIONS

ROOF COVERING CLASSIFICATION (MINIMUM): CLASS

INTERIOR WALL & CEILING FINISH REQUIREMENTS (MINIMUM):

EXIT STAIRS & EXIT PASSAGEWAYS: CLASS B

CORRIDORS & EXIT ACCESS STAIRS: CLASS C

ROOMS: CLASS C

IECC COMPLIANCE PATH

COMPLIANCE WITH IECC TO BE VERIFIED VIA ENERGY MODELING

ACCESSIBILITY

APPLICABLE CODES:

• PROJECT SHALL COMPLY WITH IBC CHAPTER 11, ICC/ANSI A117.1, (2017)

• PUBLIC & COMMON AREAS SHALL COMPLY WITH 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN

PARKING REQUIREMENTS

VEHICLE PARKING REQUIREMENTS:

COMMERCIAL

SPACES REQUIRED: TOTAL 134 SPACES PER SITE REVIEW APPROVED

SEPTEMBER 2000: 80 STANDARD STALLS + 49 SMALL

CAR STALLS

ACCESSIBLE SPACES REQUIRED: 5 ACCESSIBLE SPACES

VEHICLE PARKING PROVIDED: 85 STANDARD STALLS + 41 SMALL CAR + 6

ACCESSIBLE SPACES. TOTAL: 132

PENDING ADMINISTRATIVE MODIFICATION:

#ADR2025-00334

BIKE PARKING REQUIREMENTS:

SPACES REQUIRED: PER SITE REVIEW APPROVED SEPTEMBER 2000: 14

BICYCLE SPACES

BIKE PARKING PROVIDED: 14 SHORT TERMN, 14 LONG TERM SPACES

BUILDING CODE SUMMARY

PROJECT NUMBER:

DATE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

REVISIONS:

/1

/2

:5

:2

P

M A u to d e s k D o c s /1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

/1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

A

.r v t BO

U

LD

ER

C

O U

N

TY

C O

M M

U N

IT

Y

H U

B

8t h

St

Bo ul de r, Co

125020.00

20260309

100% IFC

BUILDING CODE

SUMMARY

G-103

LL PARKING GARAGE

PARKING GARAGE 19,620 SF

LEVEL 1

TRAINING 1,216 SF

FITNESS 582 SF

LARGE CONFERENCE 480 SF

BREAKROOM 657 SF

OPEN OFFICE - AREA A 3,260 SF

WORKFORCE LAB 595 SF

PH/VR COUNTER 404 SF

HOSPITALITY 131 SF

WAITING 351 SF

CEDM 190 SF

ISSUANCE WAITING 286 SF

ISSUANCE/SAFE 319 SF

STORAGE 170 SF

WF STORAGE 100 SF

CHILDRENS WAITIING 92 SF

JC 74 SF

OPEN OFFICE 1,024 SF

AAA / VETERANS 325 SF

FACE TO FACE 791 SF

RECEPTION 679 SF

OFFICE / FACE TO FACE 916 SF

BENEFITS 433 SF

LOBBY / OFFICE 534 SF

RESTROOM 641 SF

RESTROOM 190 SF

WELLNESS RM 111 SF

ENV HLTH REF STRG 70 SF

CIRCULATION 1,754 SF

CIRCULATION 2,070 SF

RESTROOM 288 SF

RESTROOM 197 SF

LEVEL 2

CONF. RM 202 SF

CONF. RM 163 SF

OFFICE 4,943 SF

CONF. RM 200 SF

TRAINING RM 377 SF

STORAGE 750 SF

OFFICE 4,683 SF

PRINT / COFFEE / OPEN WK 394 SF

STORAGE 493 SF

CONF. RM 202 SF

CONFERENCE 212 SF

PATIO 189 SF

PATIO 226 SF

PATIO 232 SF

PATIO 254 SF

PATIO 316 SF

OFFICE 2,333 SF

OPEN COLLAB 631 SF

RESTROOMS 643 SF

WELLNESS 80 SF

CIRCULATION 99 SF

CIRCULATION 443 SF

CIRCULATION 98 SF

CIRCULATION 198 SF

CIRCULATION 172 SF

CIRCULATION 594 SF

OPEN MEETING 138 SF

GRAND TOTAL 57,814 SF

OCCUPANT LOAD BY LEVEL - AREAS

OCCUPANCY OCCUPANT

LOAD

FACTOR

OCCUPANT

LOAD AREATABLE 1004.1.2 - USE DESCRIPTION

LL PARKING GARAGE

Parking Garages 200 99 19,620 SF

99 19,620 SF

LEVEL 1

Accessory storage areas, mechanical equipment room 300 4 414 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 136 1,997 SF

Business Areas -150 150 103 14,126 SF

Educational - Classroom area - Net Area 20 91 1,811 SF

Exercise Rooms 50 12 582 SF

346 18,931 SF

LEVEL 2

Accessory storage areas, mechanical equipment room 300 5 1,243 SF

Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 188 2,711 SF

Business Areas -150 150 108 15,310 SF

301 19,263 SF

GRAND TOTAL 746 57,814 SF

PLUMBING FIXTURE CALCULATIONS - AREAS

OCCUPANCY

AREA

OCCUPANT

LOAD

DESIGN POPULATION WATER CLOSETS LAVS

DF

REQ'D.

DF

PROVIDEDTABLE 2902.1 CLASSIFICATION MEN WOMEN

MEN

REQ'D.

MEN

PROVIDED

WOMEN

REQ'D.

WOMEN

PROVIDED

MEN

REQ'D.

MEN

PROVIDED

WOMEN

REQ'D.

WOMEN

PROVIDED

LL PARKING GARAGE

S1 & S2 - Storage, Warehouses, Freight Depots 19,620 SF 0 0 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0

19,620 SF 0 0 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0

LEVEL 1

(none) 5,140 SF 0 0 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0

A3 - Auditoriums, Galleries, Museums, Lecture Halls, Libraries, Arcades and Gymnasiums 2,393 SF 100 50 50 0.40 1 0.77 2 0.25 1 0.25 1 0.20 0

B - Business 10,983 SF 205 103 103 3.06 4 3.06 4 2.29 3 2.29 4 2.05 4

S1 & S2 - Storage, Warehouses, Freight Depots 414 SF 4 2 2 0.02 1 0.02 1 0.02 0 0.02 0 0.00 0

18,931 SF 309 155 155 3.48 6 3.85 7 2.56 4 2.56 5 2.25 4

LEVEL 2

(none) 2,877 SF 0 0 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0

B - Business 15,144 SF 279 140 140 3.80 4 3.80 3 2.75 2 2.75 2 2.79 2

S1 & S2 - Storage, Warehouses, Freight Depots 1,243 SF 5 3 3 0.03 0 0.03 0 0.03 0 0.03 0 0.00 0

19,263 SF 284 143 143 3.83 4 3.83 3 2.78 2 2.78 2 2.79 2

OCCUPANT LOAD CALCULATIONS - AREAS

NAME AREA

OCCUPANCY

GROUP

OCCUPANCY OCCUPANT

LOAD

FACTOR

OCCUPANT

LOADTABLE 1004.1.2 - USE DESCRIPTION

LL PARKING GARAGE

PARKING GARAGE 19,620 SF S-2 Parking Garages 200 99

19,620 SF 99

LEVEL 1

ENV HLTH REF STRG 70 SF S-2 Accessory storage areas, mechanical equipment room 300 1

JC 74 SF S-2 Accessory storage areas, mechanical equipment room 300 1

STORAGE 170 SF S-2 Accessory storage areas, mechanical equipment room 300 1

WF STORAGE 100 SF S-2 Accessory storage areas, mechanical equipment room 300 1

BREAKROOM 657 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 44

CHILDRENS WAITIING 92 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 7

HOSPITALITY 131 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 9

ISSUANCE WAITING 286 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 20

LARGE CONFERENCE 480 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 32

WAITING 351 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 24

AAA / VETERANS 325 SF B Business Areas -150 150 3

BENEFITS 433 SF B Business Areas -150 150 3

CEDM 190 SF B Business Areas -150 150 2

CIRCULATION 3,824 SF B Business Areas -150 150 26

FACE TO FACE 791 SF B Business Areas -150 150 6

ISSUANCE/SAFE 319 SF B Business Areas -150 150 3

LOBBY / OFFICE 534 SF B Business Areas -150 150 4

OFFICE / FACE TO FACE 916 SF B Business Areas -150 150 7

OPEN OFFICE 1,024 SF B Business Areas -150 150 7

OPEN OFFICE - AREA A 3,260 SF B Business Areas -150 150 22

PH/VR COUNTER 404 SF B Business Areas -150 150 3

RECEPTION 679 SF B Business Areas -150 150 5

RESTROOM 1,317 SF B Business Areas -150 150 11

WELLNESS RM 111 SF B Business Areas -150 150 1

TRAINING 1,216 SF A-3 Educational - Classroom area - Net Area 20 61

WORKFORCE LAB 595 SF B Educational - Classroom area - Net Area 20 30

FITNESS 582 SF A-3 Exercise Rooms 50 12

18,931 SF 346

LEVEL 2

STORAGE 1,243 SF S-2 Accessory storage areas, mechanical equipment room 300 5

CONF. RM 767 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 53

CONFERENCE 212 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 15

OPEN MEETING 138 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 10

PATIO 1,216 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 84

TRAINING RM 377 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area

15 26

CIRCULATION 1,604 SF B Business Areas -150 150 13

OFFICE 11,959 SF B Business Areas -150 150 81

OPEN COLLAB 631 SF B Business Areas -150 150 5

PRINT / COFFEE / OPEN WK 394 SF B Business Areas -150 150 3

RESTROOMS 643 SF B Business Areas -150 150 5

WELLNESS 80 SF B Business Areas -150 150 1

19,263 SF 301

GRAND TOTAL 57,814 SF 746

*** CIRCULATION, CORRIDORS AND RESTROOMS OCCUPANT LOAD NOT INCLUDED IN PLUMBING FIXTURE COUNTS

PROJECT NUMBER:

DATE:

SHEET NUMBER

SHEET TITLE:

ISSUED FOR:

REVISIONS:

/1

/2

:5

:3

P

M A u to d e s k D o c s /1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

/1

.0

B o u ld e r

C o u n ty

C o m m u n it y H u b

A

.r v t BO

U

LD

ER

C

O U

N

TY

C O

M M

U N

IT

Y

H U

B

8t h

St

Bo ul de r, Co

125020.00

20260309

100% IFC

ENERGY COMPLIANCE

CHECKLIST

G-400

SIGNAGE TYPE SCHEDULE - IBC 2024

SIGN

DESIGNATION

A

SIGN TYPE

ROOM NUMBER

LOCATION

AS INDICATED ON PLANS

CODE REFERENCE

VISUAL

CHARACTERS

YES

TACTILE BRAILLE PICTOGRAM

INT'L SYMBOL OF

ACCESSIBILITY PLACEMENT

POST OR BUILDING-MOUNTED CENTERED ON PARKING SPACE, 0" TO BOTTOM OF SIGN

COMMENTS

B

ACCESSIBLE ENTRANCE ENTRANCES WHERE NOT ALL ARE ACCESSIBLE ENTRANCE TO ELEMENT

C

AREA OF REFUGE AREAS OF REFUGE & EXTERIOR AREAS FOR EVACUATION ASSISTANCE

D

ACCESSIBLE PARKING PAVEMENT MARKING ACCESSIBLE PARKING STALLS CENTERED ON PARKING STALL, ALIGNED WITH FRONT NOT REQUIRED BY CODE

E

ASSISTIVE LISTENING SYSTEM ASSEMBLY SPACES WITH ASSISTIVE LISTENING SYSTEM NEAR ENTRANCE TO ROOM PICTOGRAM TO BE INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS

F

2-WAY COMMUNICATION ADJACENT TO 2-WAY COMMUNICATION DEVICES INCLUDING ELEVATOR LANDINGS AT LEVEL 2 AND ABOVE ADJACENT TO 2-WAY COMMUNICATION DEVICES

G

DIRECTIONAL INACCESSIBLE ENTRANCES, TOILET ROOMS & BATHING FACILITIES, ELEVATORS NOT SERVING AN ACCESSIBLE ROUTE, EXITS & EXIT STAIRS NOT PROVIDING AN ACCESSIBLE MEANS OF EGRESS, ELEVATOR LANDINGS &

WITHIN AREAS OF REFUGE

H

TOILET ROOM ACCESSIBLE TOILET ROOMS

I

STAIR IDENTIFICATION INSIDE STAIR ENCLOSURE AT EACH STAIR LANDING VISIBLE WHEN DOOR IS OPEN OR CLOSED

J

EXIT STAIR EXIT STAIRS ABOVE EACH ELEVATOR CALL BUTTON NOT USED AT ENTRY LEVEL & ELEVATORS PART OF AN ACCESSIBLE MEANS OF EGRESS OR USED FOR SELF-EVACUATION

K

EMPLOYEE ONLY AS INDICATED ON PLANS BOTH ELEVATOR JAMBS

L

ROOM IDENTIFICATION OUTSIDE ROOM ROOM SIGNS ARE NOT REQUIRED BUT IF PROVIDED THEY MUST MEET REQUIREMENTS

M LOCKED DOOR MAIN ENTRY DOORS WITH LOCKS DOOR FRAME ABOVE DOOR ALLOWED AT MAIN DOORS OF GROUP A WITH A MAXIMUM OCCUPANT LOAD OF 300 AND GROUP B, F, M & S

N

RATED WALL ABOVE CEILING AT ALL RATED WALLS WITHIN 15' OF END OF WALL & 30' O.C. ALONG LENGTH OF WALL NOT REQUIRED IN R-2 OCCUPANCY WHERE CEILING IS NOT ACCESSIBLE

O

MAXIMUM OCCUPANCY ASSEMBLY OCCUPANCY SPACES CONSPICUOUS PLACE NEAR MAIN DOOR MAXIMUM OCCUPANCY OF ROOM PER CODE PLAN

P

TACTILE EXIT DOORS AT: EXTERIOR EXIT DOORS, EXIT STAIRS & RAMPS, EXIT PASSAGEWAYS, AREAS OF REFUGE, AND EXTERIOR AREAS FOR RESCUE ASSISTANCE

Q

R NO SMOKING BUILDING ENTRIES CONSPICUOUS PLACE NEAR DOOR REQUIRED FOR LEED

S

STOP SIGN AS INDICATED ON PLANS POST-MOUNTED, 5'-0" TO BOTTOM OF SIGN

TRAFFIC AS INDICATED ON PLANS POST OR BUILDING-MOUNTED, 5'-0" TO BOTTOM OF SIGN

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

NO

NO

YES

NO

NO

NO

NO

YES

YES

NO

YES

YES

NO

NO

NO

YES

NO

NO

NO

NO

NO

NO

NO

YES

YES

NO

YES

NO

YES

NO

NO

NO

NO

NO

NO

YES

NO

NO

YES

YES

YES

YES

NO

NO

YES

YES

NO

NO

YES

NO

NO

NO

NO

YES

YES

NO

YES

YES

NO

NO

NO

YES

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

SEE PLAN FOR SIGN CONTENT

IBC 1111.1

IBC 1009.9 & 1009.11

NA

IBC 1111.3 & 1108.2.7

IBC 1009.8.2, 1009.10 & 1009.11

IBC 1111.1 & 1009.10

IBC 2902.4 & 1111

IBC 1023.9

ADAAG 216.2

IBC 1010.1.9.4

IBC 703.7

IBC 1004.9

IBC 1013.4

NA

NA

NA

AT DOOR TO REFUGE AREA ILLUMINATION ALSO REQUIRED

NA

NA

NA

NOTES:

1. SIGNAGE TO COMPLY WITH ICC A.117.1 703.2 AND ADA CHAPTER 7.

2. SIGNAGE TO COMPLY WITH COLORADO

3. MOUNT SIGNS 4" CLEAR TO LATCH-SIDE DOOR JAMB U.O.N

4. MOUNT TOP OF SIGNS AT 5'-0" AFF U.O.N.

5. WHEN TWO SIGNS ARE NEXT TO EACH OTHER, ALIGN TOP HEIGHT U.O.N.

6. WHERE NOTED IN SCHEDULE, SPANISH TEXT AND LINE ABOVE TO BE FLAT (IN VINYL

WHEN DONE BY CLIENT)

7. TYPICAL SIGN ON 1/8" THICK BASE, OVER 1/16" THICK BACKDROP, 3/8" OFFSET

8. BRAILLE INDICATED BELOW IS ONLY REPRESENTATIVE FOR LOCATION AND SIZE

Name Spanish

/2

/2

/8

/8

" 2

NAME

1" TEXT RAISED 1/32"

GRADE 2 BRAILE

VINYL LINE BY CLIENT

VINYL SPANISH

BY CLIENT

WHERE NOTED

PICTOGRAM RAISED 1/32"

VARIES

TEXT

TEXT

/2

/8

/8

/8

/8

/4

/4

3/8" 5 1/4" 3/8"

1" TEXT RAISED 1/32"

GRADE 2 BRAILE

PICTOGRAM

3"

E Q

/4

/8

/8

E Q

5/8" TEXT

RAISED 1/32"

SIGN BASE,

TYPICAL

GRADE 2

BRAILE

R# - ROOM NUMBER

3X3

ROOM NAME MEDIUM

9x3

NAME

NAME

E Q

/8

/8

/8

/8

/4

E Q

GRADE 2

BRAILE

9"

ROOM NAME LARGE (2 VERSIONS)

9X6

NAME

E Q

/8

/8

/4

E Q

6"

NAME

NAME

E Q

/8

/8

/8

/8

/4

E Q

GRADE 2

BRAILE

9"

DIVISION SIGN

9X6

NAME

E Q

/8

/8

/4

E Q

9"

5/8" TEXT

RAISED 1/32"

5/8" TEXT

RAISED 1/32"

6"

5/8" TEXT

RAISED 1/32"

GRADE 2

BRAILE

RS - ROOM SUITE

6X6

E Q

RESTROOM

BANO

/2

/2

/8

/8

/4

/4

9"

3/8" 5 1/4" 3/8"

VARIES

RESTROOM

BANO

/2

/8

/8

/4

/…

This is the start of the file's text. The full file is on GovTribe.