9-3. 2026 03 10 Hub IFC Arch.pdf
PDF 26 MB Posted
- Attached to
- 28th St Hub Doors, Frames & Hardware
- Solicitation number
- BID-269-26
- Issued by
- Boulder County, Colorado
About this file
This is an Invitation for Bid (IFB) issued by Boulder County Building Services, a Division of Public Works, for the furnishing of interior doors, frames, and hardware for the Boulder County Community Hub located at 2525 28th Street, Boulder, Colorado 80301. The project is a 39,560-square-foot, two-story non-residential office tenant improvement and roof replacement for Boulder County, with work exceeding 50 percent of the building area. The bid documents include comprehensive architectural drawings and specifications detailing all required materials, including door schedules, frame types, hardware sets, and installation requirements across multiple levels (lower level parking garage, Level 1, and Level 2). The project team includes representatives from various disciplines such as structural engineering, sustainability consulting, architecture, civil engineering, landscape design, cost estimation, and mechanical/electrical trades. Installation of all furnishings is to be performed by Boulder County as the General Contractor, with bidders required to furnish materials only. Bidders may submit product substitutions that meet or exceed all quality and capacity requirements, provided they comply with specifications; however, certain materials designated as "Basis-of-Design" products cannot be substituted.
The bid documents specify that all bidders must comply with quality, capacity, and specification requirements outlined in the architectural and construction documents dated March 10, 2026 (100% IFC set). Proposed product substitutions must be submitted with bid questions and do not require a formal substitution request form. The procurement process is administered by Boulder County, and inquiries regarding procurement procedures should be directed to procurement@bouldercounty.gov. All work must comply with the 2024 International Building Code, applicable Colorado codes, and local amendments as specified in the project documents. The project includes detailed door schedules identifying specific hardware sets, frame finishes, and installation locations throughout the facility. Americans with Disabilities Act (ADA) and Equal Opportunity compliance requirements apply to all bidders and their proposed work.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TRUE
NORTH
BOULDER COUNTY PUBLIC WORKS
KARLA SCHULTZ
2525 13TH STREET
BOULDER, CO 80304
PHONE: 720.415.5766
STRUCTURAL
LAURA A. COATES
JVA INC.
STREET1319 SPRUCE ST
BOULDER, CO 80302
PHONE: 303.565.4939
SUSTAINABILITY CONSULTANT
LAURA CHARLIER
GROUP 14
1325 EAST 16TH AVE
DENVER, CO 80218
PHONE: 720.221.1074
ARCHITECT
OZ ARCHITECTURE
TRACY BOYER
3003 LARIMER STREET
DENVER, CO, 80205
PHONE: 303.861.5704
CIVIL
CODY F. GRANTY
JVA INC.
1319 SPRUCE ST
BOULDER, CO 80302
PHONE: 303.565.4966
LANDSCAPE
SANDI GIBSON
OUTSIDE L.A.
BOULDER, CO
PHONE: 303.517.9256
COST ESTIMATOR
MELISSA CHABOT
VERMEULENS
100 FILMORE ST
DENVER, CO 80206
PHONE: 857.294.0677
ELECTRICAL / TECHNOLOGY
BRIAN D. JOHNSON
AE DESIGN
1900 WAZEE ST SUITE 205
DENVER, CO 80202
PHONE: 303.296.3036
MECHANICAL / PLUMBING
MILES DAKE
DAKE COLLABORATIVE
3435 S INCA ST, SUITE C
ENGLEWOOD, CO 80110
PHONE: 720.583.4735
SIG
NATURE B
LO
CK
/1
/2
:5
:1
P
M A u to d e s k D o c s /1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
/1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
A
.r v t
BOULDER COUNTY COMMUNITY HUB
100% IFC - 20260309
2525 28th St.
Boulder, Co 80301
IMAGE IS REPRESENTATIVE ONLY
SET ISSUE INDEX VICINITY MAP PROJECT TEAM
03.10.2026
STRUCTURAL GRID WINDOW IDENTIFICATION
DOOR IDENTIFICATION
GLAZING IDENTIFICATION
FLAG NOTE IDENTIFICATION
ROOM/SPACE IDENTIFICATION ROOM/FINISH IDENTIFICATION
RCP/FINISH IDENTIFICATION
CODE ROOM/SPACE IDENTIFICATION
ELEVATION REFERENCE
MATERIAL PATTERNS
BUILDING SECTION IDENTIFICATION
WALL/DETAIL SECTION IDENTIFICATION
ENLARGED DETAIL IDENTIFICATION
PARTITION TYPE IDENTIFICATION
ACOUSTIC PARTITION TYPE
IDENTIFICATION
ASSEMBLY IDENTIFICATION
C
COLUMN NUMBER
COLUMN GRID
REFERENCE LINE
COLUMN LETTER
WINDOW TYPE
A
G2
GLAZING TYPE
DOOR NUMBER
ROOM NAME
ROOM NUMBER
ROOM AREA*
ROOM NAME
ROOM NUMBER
CPT-01
WALL FIN.
BASE TYPE
FLOOR FIN. TYPE
ROOM NAME
ROOM NUMBER
CEILING FIN.
ELEVATION
DATUM POINT
LOCATION
102' - 6"
DRAWING NUMBER
SHEET NUMBER
DRAWING NUMBER
SHEET NUMBER
23A
PARTITION TYPE
RE: PARTITION
TYPE SHEET
HEAD OF WALL TYPE RE:
PARTITION TYPE SHEET
23A
PARTITION TYPE
RE: PARTITION
TYPE SHEET
HEAD OF WALL TYPE RE:
PARTITION TYPE SHEET
E1
EXTERIOR WALL
ASSEMBLY TYPE
F1
FLOOR
ASSEMBLY TYPE
C2
CEILING
ASSEMBLY TYPE
R3
ROOF
ASSEMBLY TYPE
* ROOM AREAS:
VERIFY BASIS OF MEASUREMENT USED BY ARCHITECT. MAY BE CALCULATED TO
CENTERLINE OF SURROUNDING PARTITIONS OR TO INSIDE FINISH SURFACES.
CONCRETE
UNDISTURBED OR
COMPACTED EARTH
POROUS FILL
(GRAVEL)
STEEL
ALUMINUM
MASONRY - BRICK
MASONRY -
CONCRETE BLOCK
INSULATION - RIGID
INSULATION - BATT
GYPSUM - PLASTER
PLYWOOD
FINISH WOOD
ROUGH WOOD
ACOUSTIC TILE
9.15 NOTE NUMBER
FINISH IDENTIFICATION
P FINISH TYPE
ACCESSORY IDENTIFICATION
ACCESSORY TYPE1i
DRAWING NUMBER
SHEET NUMBER
/ A
-3
2 / A-401
ROOM
788 SF GROSS
RESIDENTIAL
R-2
200 SF/OCC
3 OCCUPANTS
1 EXITS REQ'D
ROOM NAME
AREA* & TYPE (GROSS OR NET)
FUNCTION OF SPACE
(TABLE 1004.1.2)
OCCUPANT LOAD FACTOR
TOTAL OCCUPANTS
EXITS REQUIRED
OCCUPANCY GROUP
RB-01
P-01
ROOM
P-01
ROOM
ROOM
2,828 SF
/ A
-3
INTERIOR ELEV. IDENTIFICATION
EXTERIOR ELEV. IDENTIFICATION
DRAWING NUMBER
SHEET NUMBERA-701
DRAWING NUMBER
SHEET NUMBER
2 / A-201
H W D
MOD DESCRIPTION UNIQUE MODIFIER
CASEWORK IDENTIFICATION
CASEWORK DESIGN
SERIES (CDS) NUMBER
CASEWORK DIMENSION
DIMENSION IDENTIFICATION
X'-X"
X'-X"
MEASURED FROM
FACE OF STUD, UNO
MEASURED FROM
FACE OF FINISH, UNO
1. THE TERM “GC” SHALL MEAN THE GENERAL CONTRACTOR AND ITS SUB-CONTRACTORS.
2. THE GC SHALL THOROUGHLY FAMILIARIZE ITSELF WITH THE CONTRACT DOCUMENTS AND THE SITE.
SHOULD THE GC FIND DISCREPANCIES IN, OR OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS, SHOULD THE GC BE IN DOUBT AS TO THEIR INTENT OR MEANING, OR HAS QUESTIONS CONCERNING
CONSTRUCTABILITY OR CODE COMPLIANCE, THE GC SHALL SEEK CLARIFICATION FROM THE
ARCHITECT BEFORE PROCEEDING WITH THE WORK. SHOULD A CONFLICT OCCUR BETWEEN THE
DRAWINGS AND SPECIFICATIONS, THE GC SHALL SEEK CLARIFICATION FROM THE ARCHITECT.
3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO PROVIDE A COMPLETE PROJECT. EVERY ITEM NECESSARILY REQUIRED MAY NOT BE SPECIFICALLY MENTIONED OR SHOWN. UNLESS EXPRESSLY STATED, SYSTEMS AND EQUIPMENT SHALL BE COMPLETELY OPERATIONAL. PROVIDE INCIDENTAL, ACCESSORY, AND ANY OTHER ITEMS NOT SPECIFIED, BUT REQUIRED, FOR A COMPLETE AND
FINISHED ASSEMBLY.
4. THE ENTIRE SET OF CONTRACT DOCUMENTS REPRESENT THE PROJECT AS A WHOLE. THE GC IS RESPONSIBLE FOR PROVIDING SUFFICIENT INFORMATION TO ITS SUB-CONTRACTORS TO DETERMINE
AND PERFORM THEIR SCOPE OF WORK.
5. ANY ELECTRONIC CAD AND/OR BUILDING INFORMATION MODELING (BIM) FILES PROVIDED BY THE
ARCHITECT OR ITS CONSULTANTS IS SOLELY TO ASSIST THE GC IN PREPARATION OF SHOP
DRAWINGS AND/OR LAYOUT OF THE PROJECT. CAD AND BIM FILES ARE NOT A PART OF THE
CONTRACT DOCUMENTS AND ANY INFORMATION CONTAINED THEREIN DOES NOT SUPERSEDE ANY
INFORMATION ON THE CONTRACT DOCUMENTS.
6. THE GC IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION, COORDINATION OF
TRADES, AND SCHEDULING OF THE WORK.
7. THE GC SHALL NOT REVISE, SUBSTITUTE, OR CHANGE THE WORK WITHOUT THE WRITTEN CONSENT
OF THE ARCHITECT.
8. NOT EVERY CONDITION MAY BE DRAWN OR DETAILED. CONDITIONS SIMILAR TO DETAILED
CONDITIONS SHALL BE CONSTRUCTED TO THE SAME SIZE AND CHARACTER AS THOSE FOR SIMILAR
CONDITIONS.
9. THE GC SHALL FOLLOW THE RECOMMENDATIONS OF THE OWNER’S GEOTECHNICAL CONSULTANT.
SHOULD THE GC FIND DISCREPANCIES WITH THE CONTRACT DOCUMENTS, THE GC SHALL SEEK
CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
10. DO NOT SCALE DRAWINGS.
11. PROVIDE NECESSARY BLOCKING IN WALLS, PARTITIONS, AND CEILINGS FOR ITEMS INCLUDING, BUT
NOT LIMITED TO: CEILING AND PARTITION-MOUNTED FIXTURES, GRAB BARS, HANDRAILS, TOILET ACCESSORIES, CABINETRY, PANELING, COUNTERTOPS, SHELVES, CLOSET RODS, WHITE BOARDS, AND DECORATIVE ELEMENTS.
12. THE CONSTRUCTION DOCUMENTS ARE THE PROPERTY OF OZ ARCHITECTURE, INC. AND ITS
CONSULTANTS AND ARE TO BE USED AS INSTRUMENTS OF SERVICE FOR CONSTRUCTION OF THIS
PROJECT ONLY. USE OF THESE DOCUMENTS BY THE GC FOR ANY OTHER PROJECT OR PURPOSE
WITHOUT THE WRITTEN CONSENT OF OZ ARCHITECTURE IS PROHIBITED.
13. EL.100'-0" EQUATES TO USGS DATUM ELEVATION OF ______.
14. REFER TO ALTA SURVEY FOR BASIS OF BEARINGS, PROPERTY LINES, AND ASSOCIATED
INFORMATION.
15. REFER TO GEOTECHNICAL REPORT FOR ADDITIONAL CLARIFICATIONS ON SUB-GRADE DESIGN
RECOMMENDATIONS AND LIMITATIONS.
39,560 SF, 2 STORY NON-RESIDENTIAL BUILDING, OFFICE TENATE IMPROVEMENT FOR BOULDER
COUNTY
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/1
/2
:5
:1
P
M A u to d e s k D o c s /1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
/1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
A
.r v t BO
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
Bo ul de r, Co
125020.00
20260309
100% IFC
PROJECT INFORMATION,
ABBREVIATIONS, SHEET
INDEX
G-010
DRAWING INDEXABBREVIATIONS
GRAPHIC STANDARDS
GENERAL NOTES
PROJECT DESCRIPTION
# POUND(S) or NUMBER
& AND
< ANGLE
@ AT
AB ANCHOR BOLT
ACT ACOUSTICAL CEILING TILE
ADA AMERICAN DISABILITY ACT
ADD ADDENDUM
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISH GRADE
AGGR AGGREGATE
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
ARCH ARCHITECT / ARCHITECTURAL
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS
ASPH ASPHALT
ASSY ASSEMBLY
AV AUDIO / VISUAL
AVE AVENUE
AVG AVERAGE
AWP ACOUSTICAL WALL PANEL
B.O. BOTTOM OF
BALC BALCONY
BD BOARD
BIM BUILDING INFORMATION MODELING
BLDG BUILDING
BLKG BLOCKING
BOD BASIS OF DESIGN
BR BEDROOM
BRG BEARING
BSMT BASEMENT
BTWN BETWEEN
CA CONSTRUCTION ADMINISTRATION
CAB CABINET
CCD CONSTRUCTION CHANGE DIRECTIVE
CCTV CLOSED CIRCUIT TELEVISION
CD CONSTRUCTION DOCUMENTS
CDOT COLORADO DEPARTMENT OF TRANSPORTATION
CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CFM COLD FORMED METAL
CG CORNER GUARD
CI CONTINUOUS INSULATION
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLL COLUMN LINE
CLO CLOSET
CLR CLEAR
CLT CROSS LAMINATED TIMBER
CM CENTIMETERS
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONF CONFERENCE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTV CABLE TELEVISION
CU CUBIC
CUH CABINET UNIT HEATER
CY CUBIC YARD
DBL DOUBLE
DD DESIGN DEVELOPMENT
DEG DEGREE
DEMO DEMOLISH / DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DH DOUBLE-HUNG
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DN DOWN
DP DESIGN PRESSURE
DR DINING ROOM
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWR DRAWER
(E) EXISTING
E EAST
EA EACH
EF EACH FACE
EJ EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENGR ENGINEER
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
ESMT EASEMENT
EST ESTIMATE
EUH ELECTRIC UNIT HEATER
EXCL EXCLUDE(D)
EXH EXHAUST
EXP EXPOSED
EXT EXTERIOR
F FARENHEIT
F.O. FACE OF
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FCC FIRE COMMAND CENTER
FCR FIRE COMMAND ROOM
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FFE FINISHED FLOOR ELEVATION
FH FIRE HYDRANT
FHA FAIR HOUSING ACT
FIXT FIXTURE
FLG FLOORING
FLR FLOOR
FLSH FLASHING
FLUOR FLUORESCENT
FND FOUNDATION
FRG FURRING
FRP FIBERGLASS REINFORCED PANEL(ING)
FRT FIRE RETARDANT TREATED
FSD FIRE SEPARATION DISTANCE
FT FOOT (FEET)
FTG FOOTING
FURN FURNITURE
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN GENERATOR
GEO GEOTECH
GFRC GLASS-FIBER REINFORCED CONCRETE
GL GLASS / GLAZING
GLU LAM GLUE-LAMINATED
GR GRADE
GYP GYPSUM
GYP BD GYPSUM BOARD
HB HOSE BIBB
HC HOLLOW CORE
HDR HEADER
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HSKG HOUSEKEEPING
HT HEIGHT
HVAC HEATING, VENTILATION, AIR CONDITIONING
HW HOT WATER
HWY HIGHWAY
IBC INTERNATIONAL BUILDING CODE
ICC INTERNATIONAL CODE COUNCIL
ID INSIDE DIAMETER
IIC INITIAL IMPACT COEFFICIENT
IN INCH(ES)
INCAND INCANDESCENT
INCL INCLUD(ED)
INFO INFORMATION
INSUL INSULATION / INSULATED
INT INTERIOR
JAN JANITOR
JST JOIST
JT JOINT
K KING
KD KNOCKDOWN
KIT KITCHEN
KO KNOCKOUT
KPL KICK PLATE
LA LANDSCAPE
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LGMF LIGHT GAUGE METAL FRAMING
LH LEFT HAND
LIQ LIQUID
LKR LOCKER
LNTL LINTEL
LP LIGHTING POLE
LR LIVING ROOM
LT LIGHT
LV LOW VOLTAGE
LVL LAMINATED VENEER LUMBER
LVR LOUVER
M.O. MASONRY OPENING
MACH MACHINE
MAG MAGNETIC
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MEP MECHANICAL, ELECTRICAL, PLUMBING
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MM MILLIMETERS
MTD MOUNT(ED)
MTL METAL
MULL MULLION
MW MICROWAVE
(N) NEW
N NORTH
NAVD88 NORTH AMERICAN VERTICAL DATUM OF 1988
NIC NOT IN CONTRACT
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O.C. ON CENTER
O.F. OUTSIDE FACE
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OFF OFFICE
OFOI OWNER FURNISHED, OWNER INSTALLED
OH OPPOSITE HAND
OHD OVERHEAD DOOR
OLF OCCUPANT LOAD FACTOR
OPNG OPENING
OPP OPPOSITE
OVH OVERHEAD
OZ OUNCE
PAR PARALLEL
PC PRECAST
PERF PERFORATED
PERIM PERIMETER
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PLBG PLUMBING
PLY PLYWOOD
PNL PANEL
PNT PAINTED
POL POLISHED
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRIM PRIMARY
PRKG PARKING
PROJ PROJECT
PS PRESTRESSED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POST-TENSIONED CONCRETE
PTN PARTITION
PV PHOTOVOLTAIC
PVC POLYVINYL CHLORIDE
Q QUEEN
QT QUART
QTR QUARTER
QTY QUANTITY
R R-VALUE
RAD RADIUS
RB RUBBER BASE
RCL RECYCLE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN / ROAD
RE REFER TO
REC RECESS(ED)
RECPT RECEPTACLE
REF REFRIGERATOR
REINF REINFORCED
REQD REQUIRED
RESIL RESILIENT
REV REVISE / REVISED / REVISION(S)
RF RESILIENT FLOORING
RFG ROOFING
RFI REQUEST FOR INFORMATION
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RR RESTROOM(S)
RTU ROOF TOP UNIT
RW ROOM WIZARD
S SOUTH
SAF SELF-ADHERED FLASHING
SC SOLID CORE
SCHED SCHEDULE
SD SCHEMATIC DESIGN
SECT SECTION
SF SQUARE FEET
SHGC SOLAR HEAT GAIN COEFFICIENT
SHT SHEET
SHTHG SHEATHING
SHWR SHOWER
SIM SIMILAR
SPEC(S) SPECIFICATION(S)
SPKLR SPRINKLER
SPKR SPEAKER
SQ SQUARE
SS SOLID SURFACE
SSTL STAINLESS STEEL
ST STREET
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
STE SUITE
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
SURV SURVEY
SUSP SUSPEND(ED)
SYM SYMBOL
SYMM SYMMETRICAL
SYS SYSTEM
T TREAD
T&G TONGUE AND GROOVE
T.O. TOP OF
T.O.C TOP OF CONCRETE/CURB
T.O.S TOP OF STEEL/SLAB
T.O.W TOP OF WALL
TEL TELEPHONE
TELECOM TELECOMMUNICATIONS
TEMP TEMPORARY
THERM THERMAL
THK THICK
TMPD OR (T) TEMPERED
TN TECHNOLOGY
TS TUBE STEEL
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
U URBAN
UL UNDERWRITER'S LABORATORY
UNO UNLESS NOTED OTHERWISE
USGS UNITED STATES GEOLOGICAL SURVEY
V VOLT
VCT VINYL COMPOSITION TILE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VOL VOLUME
VWC VINYL WALL COVERING
W WEST
W.O. WHERE OCCURS
W/ WITH
W/D WASHER / DRYER
W/O WITHOUT
WC WALL COVERING
WD WOOD
WF WIDE FLANGE
WIN WINDOW
WRB WEATHER RESISTANT BARRIER
WSCT WAINSCOT
WT WEIGHT
XFMR TRANSFORMER
YD YARD
ZLL ZONE LOT LINE
SHEET
NUMBER SHEET NAME D
E S
IG
N
D E
V E
LO
P
M E
N T
P E
R M
IT
D
R A
W
IN
G S
C O
N S
T
B
ID
D R
A W
IN
G
S
IFC SET
GENERAL
G-000 COVER ● ● ● ●
G-010 PROJECT INFORMATION, ABBREVIATIONS, SHEET INDEX ● ● ● ●
G-100 LL PARKING GARAGE BUILDING CODE PLAN ● ● ●
G-101 LEVEL 1 BUILDING CODE PLAN ● ● ● ●
G-102 LEVEL 2 BUILDING CODE PLAN ● ● ● ●
G-103 BUILDING CODE SUMMARY ● ● ● ●
G-400 ENERGY COMPLIANCE CHECKLIST ● ● ●
G-500 SIGN TYPES ● ● ● ●
G-505 STANDARD MOUNTING HEIGHTS - ANSI 2017 ● ● ● ●
SN-01 SITE SIGN LOCATION PLAN ● ● ●
SN-02 SIGN DESIGN INTENT ● ● ●
CIVIL
C0.0 LEGEND, NOTES AND ABBREVIATIONS ● ● ● ●
C0.1 DEMOLITION PLAN ● ● ● ●
C1.1 CIVIL SITE PLAN ● ● ● ●
CD1.1 SITE DETAILS ● ● ● ●
LANDSCAPE
L1.0 EXISTING LANDSCAPE PLAN ● ● ● ●
L1.1 LANDSCAPE PLAN ● ● ● ●
L2.0 LANDSCAPE NOTES AND DETAILS ● ● ● ●
STRUCTURAL
S-001 GENERAL NOTES & STATEMENT OF SPECIAL INSPECTIONS ● ● ● ●
S-002 ABBREVIATIONS, SYMBOLS KEY, & 3D VIEW ● ● ● ●
S-100 FRAMING PLANS ● ● ● ●
S-501 TYPICAL STEEL DETAILS ● ● ● ●
ARCHITECTURE
AD-100 DEMO LL PARKING GARAGE FLOOR PLAN ● ● ● ●
AD-101 DEMO LEVEL 1 FLOOR PLAN ● ● ● ●
AD-102 DEMO LEVEL 2 FLOOR PLAN ● ● ● ●
AD-130 DEMO LL PARKING GARAGE REFLECTED CEILING PLAN ● ● ● ●
AD-131 DEMO LEVEL 1 REFLECTED CEILING PLAN ● ● ● ●
AD-132 DEMO LEVEL 2 REFLECTED CEILING PLAN ● ● ● ●
A-005 STANDARD PARTITION TYPES ● ● ● ●
A-100 LL PARKING GARAGE FLOOR PLAN ● ● ● ●
A-101 LEVEL 1 FLOOR PLAN ● ● ● ●
A-101.1 LEVEL 1 FLOOR PLAN - DIMENSIONS ● ● ●
A-102 LEVEL 2 FLOOR PLAN ● ● ● ●
A-102.1 LEVEL 2 FLOOR PLAN - DIMENSIONS ● ● ●
A-103 ROOF PLAN ● ● ● ●
A-130 LL PARKING GARAGE RCP ● ● ● ●
A-131 LEVEL 1 RCP ● ● ● ●
A-131.1 LEVEL 1 SYSTEM RCP ● ● ●
A-132 LEVEL 2 RCP ● ● ● ●
A-132.1 LEVEL 2 SYSTEM RCP ● ● ●
A-141 INTERIOR SCHEDULES ● ● ● ●
A-142 INTERIOR EQUIPMENT AND ACCESSORY SCHEDULES ● ● ● ●
A-151 LEVEL 1 FINISH PLAN ● ● ● ●
A-152 LEVEL 2 FINISH PLAN ● ● ● ●
A-161 LEVEL 1 FURNITURE PLAN ● ● ● ●
A-162 LEVEL 2 FURNITURE PLAN ● ● ● ●
A-440 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 RESTROOMS ● ● ● ●
A-441 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 RESTROOMS ● ● ● ●
A-442 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 GENDER NEUTRAL ● ● ● ●
A-443 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 SHOWERS ● ● ● ●
A-444 ENLARGED PLANS AND ELEVATIONS_LEVEL 02 RESTROOMS ● ● ● ●
A-445 ENLARGED PLANS AND ELEVATIONS_LEVEL 02 RESTROOMS ● ● ● ●
A-446 ENLARGED PLANS AND ELEVATIONS_LEVEL 01 WELCOME DESK ● ● ● ●
A-448 ENLARGED PLANS AND ELEVATIONS_FACE TO FACE ROOMS ● ● ● ●
A-449 ENLARGED PLANS AND ELEVATIONS_FACE TO FACE ROOMS ● ● ● ●
A-450 ENLARGED PLANS AND ELEVATIONS_ELEVATORS ● ● ● ●
A-451 ENLARGED PLANS AND ELEVATIONS_ELEVATORS ● ● ● ●
A-452 ENLARGED PLANS AND ELEVATIONS_ELEVATORS ● ● ● ●
A-453 ENLARGED PLANS AND ELEVATIONS ●
A-454 ENLARGED PLANS AND ELEVATIONS ● ● ● ●
A-460 INTERIOR ELEVATIONS ● ● ● ●
A-461 INTERIOR ELEVATIONS ● ● ● ●
A-462 INTERIOR ELEVATIONS ● ● ● ●
A-463 INTERIOR ELEVATIONS ● ●
A-464 INTERIOR ELEVATIONS ● ● ● ●
A-520 ROOF DETAILS ● ● ●
A-550 INTERIOR DETAILS - GENERAL ● ● ● ●
A-560 INTERIOR DETAILS - CEILINGS ● ● ●
A-570 INTERIOR DETAILS - MILLWORK ● ● ●
A-580 INTERIOR DETAILS - TRANSITIONS ● ● ●
A-600 DOOR SCHEDULE & TYPES ● ● ● ●
A-610 DOOR DETAILS ● ● ●
A-900 RENDERINGS - FOR REFERENCE ● ● ● ●
PLUMBING
P-001 PLUMBING LEGEND AND NOTES ● ● ●
P-002 PLUMBING SCHEDULES ● ● ●
PD-100U PLUMBING DEMOLITION PLAN - UNDERGROUND ● ● ●
PD-100 PLUMBING DEMOLITION PLAN - GARAGE LEVEL ● ● ●
PD-101 PLUMBING DEMOLITION PLAN - LEVEL 1 ● ● ●
PD-102 PLUMBING DEMOLITION PLAN - LEVEL 2 ● ● ●
PD-103 PLUMBING DEMOLITION PLAN - ROOF ● ● ●
P-100U PLUMBING PLAN - UNDERGROUND ● ● ●
P-100 PLUMBING PLAN - GARAGE ● ● ●
P-101 PLUMBING PLAN - LEVEL 1 ● ● ●
P-102 PLUMBING PLAN - LEVEL 2 ● ● ●
P-103 PLUMBING PLAN - ENLARGED ● ● ●
P-301 PLUMBING PLAN - ENLARGED ● ●
P-500 PLUMBING DETAILS ● ●
NO DATE DESCRIPTION
SHEET
NUMBER SHEET NAME D
E S
IG
N
D E
V E
LO
P
M E
N T
P E
R M
IT
D
R A
W
IN
G S
C O
N S
T
B
ID
D R
A W
IN
G
S
IFC SET
MECHANICAL
M-001 MECHANICAL LEGEND & NOTES ● ● ●
M-002 MECHANICAL SCHEDULES ● ● ●
M-003 MECHANICAL SCHEDULES ● ● ●
M-004 MECHANICAL SEQUENCE OF OPERATIONS ● ●
MD-100 MECHANICAL DEMOLITION PLAN - GARAGE LEVEL ● ● ●
MD-101 MECHANICAL DEMOLITION PLAN - LEVEL 1 ● ● ●
MD-102 MECHANICAL DEMOLITION PLAN - LEVEL 2 ● ● ●
MD-103 MECHANICAL DEMOLITION PLAN - LEVEL 3 ● ● ●
M-100 MECHANICAL PLAN - GARAGE LEVEL ● ● ●
M-101 MECHANICAL PLAN - LEVEL 1 ● ● ●
M-102 MECHANICAL PLAN - LEVEL 2 ● ● ●
M-103 MECHANICAL PLAN - LEVEL 3 ● ● ●
M-500 MECHANICAL DETAILS ● ●
ELECTRICAL
E-000 ELECTRICAL COVER SHEET ● ● ● ●
E-010 ELECTRICAL SITE PLAN ● ● ● ●
ED-100 ELECTRICAL DEMOLITION POWER PLAN - LL PARKING GARAGE ● ● ● ●
ED-101 ELECTRICAL DEMOLITION POWER PLAN - LEVEL 1 ● ● ● ●
ED-102 ELECTRICAL DEMOLITION POWER PLAN - LEVEL 2 ● ● ● ●
ED-200 ELECTRICAL DEMOLITION LIGHTING PLAN - LL PARKING GARAGE ● ● ● ●
ED-201 ELECTRICAL DEMOLITION LIGHTING PLAN - LEVEL 1 ● ● ● ●
ED-202 ELECTRICAL DEMOLITION LIGHTING PLAN - LEVEL 2 ● ● ● ●
E-100 ELECTRICAL POWER PLAN - LL PARKING GARAGE ● ● ● ●
E-101 ELECTRICAL POWER PLAN - LEVEL 1 ● ● ● ●
E-102 ELECTRICAL POWER PLAN - LEVEL 2 ● ● ● ●
E-103 ELECTRICAL POWER PLAN - ROOF ● ● ● ●
E-200 ELECTRICAL LIGHTING PLAN - LL PARKING GARAGE ● ● ● ●
E-201 ELECTRICAL LIGHTING PLAN - LEVEL 1 ● ● ● ●
E-202 ELECTRICAL LIGHTING PLAN - LEVEL 2 ● ● ● ●
E-600 ELECTRICAL EXISTING ONE-LINE DIAGRAM ● ● ● ●
E-601 ELECTRICAL NEW ONE-LINE DIAGRAM ● ● ● ●
E-700 ELECTRICAL PANEL SCHEDULES AND DETAILS ● ● ● ●
E-710 ELECTRICAL PANEL SCHEDULES ● ● ● ●
E-711 ELECTRICAL PANEL SCHEDULES ● ● ● ●
E-712 ELECTRICAL PANEL SCHEDULES ● ● ● ●
E-713 ELECTRICAL PANEL SCHEDULES ● ● ● ●
E-800 ELECTRICAL LIGHTING SCHEDULES ● ● ● ●
E-801 ELECTRICAL LIGHTING CONTROLS SCHEDULES ● ● ● ●
E-900 ELECTRICAL LIGHTING COMPLIANCE ● ● ● ●
03.10.202603.10.2026
UP
UP
DO
W
N
UP
Stair #2
Stair #1
Lobby
Equip.
Elevator
Elevator Stair #3
Storage
Parking Bicycle
Stair #5
Parking
Valve Room
Equipment Electrical Protection
Fire
UP
8.0' WIDE PSCO EASEMENT
REC. NO. 21812927
WATERLINE EASEMENT
REC. NO. 2201480
FOUND 1 1/2" ALUMINUM
COLLAR IN CONCRETE "DB
CO PLS 23529"
UTILITY EASEMENT TO THE CITY OF BOULDER
REC. NO. 2096393 & NO. 2155900
54 PAINTED GARAGE
SPACES
2 HC SPACES
5 SPACES
SIDEWALK EASEMENT
REC. NO. 2096392 & REC. NO. 2155901
PARCEL A
EXCEPTED PORTION
REC.
M U
LC
H
D
IR
T
MULCH
N89°47'18"E 380.80' (C)
EAST 380.8' (TC)9
.9
N89°47'18"E 338.82' (C)
CHASE
GARAGE EXIT
GARAGE ENTRANCE
C O N C
B
LO
C K
S T A
IR
W E
LL
CHASE
CONC.
WALL
FOUND
8.0' WIDE PSCO EASEMENT
REC. NO. 21812927
WATERLINE EASEMENT
REC. NO. 2201480
FOUND 1 1/2" ALUMINUM
COLLAR IN CONCRETE "DB
CO PLS 23529"
UTILITY EASEMENT TO THE CITY OF BOULDER
REC. NO. 2096393 & NO. 2155900
54 PAINTED GARAGE
SPACES
2 HC SPACES
5 SPACES
SIDEWALK EASEMENT
REC. NO. 2096392 & REC. NO. 2155901
PARCEL A
EXCEPTED PORTION
REC.
M U
LC
H
D
IR
T
MULCH
N89°47'18"E 380.80' (C)
EAST 380.8' (TC)9
.9
N89°47'18"E 338.82' (C)
CHASE
GARAGE EXIT
GARAGE ENTRANCE
C O N C
B
LO
C K
S T A
IR
W E
LL
CHASE
CONC.
WALL
FOUND
ASSEMBLY RATING
NON-RATED ASSEMBLY
1 HOUR ASSEMBLY
2 HOUR ASSEMBLY
3 HOUR ASSEMBLY
4 HOUR ASSEMBLY
ASSEMBLY TYPE
BW BEARING WALL (IBC SECTION 704)
FW FIRE WALL (IBC SECTION 706)
FB FIRE BARRIER (IBC SECTION 707)
FP FIRE PARTITION (IBC SECTION 708)
SB SMOKE BARRIER (IBC SECTION 709)
SP SMOKE PARTITION (IBC SECTION 710)
SE SHAFT ENCLOSURE (IBC SECTION 713)
OCCUPANT LOAD
EGRESS DIRECTION
FIRE EXTINGUISHER
FE
FDC
FACP
KB KNOX BOX
EXIT ST-N
203 OCCUPANTS
0.2"/OCC = 3'-4" REQ'D
3'-8" PROVIDED
EXIT STAIR NAME OR
DOOR NUMBER
NUMBER OF OCCUPANTS
REQ'D EGRESS WIDTH
CALCULATIONS
PROVIDED EGRESS WIDTH
BIKE STORAGE
300 SF GROSS
ACCESSORY STORAGE
R-2
300 SF/OCC
2 OCCUPANTS
1 EXITS REQ'D
ROOM NAME
AREA & TYPE (GROSS OR NET)
FUNCTION OF SPACE
(TABLE 1004.1.2)
OCCUPANT LOAD FACTOR
TOTAL OCCUPANTS
EXITS REQUIRED
OCCUPANCY GROUP
GARAGE PATH
220'-10"
LOBBY PATH
30'-5"
TRAVEL DISTANCE PATH NAME
ACTUAL TRAVEL DISTANCE,
SEE SCHEDULE FOR
ALLOWABLE
EGRESS PATH
COMMON PATH OF TRAVEL NAME
ACTUAL TRAVEL DISTANCE,
SEE SCHEDULE FOR
ALLOWABLE
CONVERGENT OCCUPANT LOAD
EGRESS DIRECTION
FIRE DEPARTMENT
CONNECTION
FIRE ALARM
CONTROL PANEL
ACCESSIBLE PATH OF TRAVEL
EGRESS PATH
CODE SHEET GRAPHICS LEGEND
EXIT SIGN
1. BUILDING SHALL BE SPRINKLERED THROUGHOUT IN ACCORDANCE WITH IBC CHAPTER 9 AND
NFPA (13). PROVIDE DRY SPRINKLER SYSTEM WHERE APPROPRIATE AND AT ALL UNCONDITIONED
LOCATIONS
2. AREA OF REFUGE IS NOT REQUIRED PER 1009.3.3 EXCEPTION NO.2
3. ELEVATOR TO COMPLY WITH STRETCHER DIMENSIONS AS REQUIRED BY IBC CHAPTER 30
4. SEE A-000 SERIES SHEETS FOR LISTED ASSEMBLIES FOR FLOOR/CEILINGS, ROOF/CEILINGS, EXTERIOR WALLS, AND PARTITIONS. LISTED FIRE-RESISTIVE ASSEMBLIES MAY BE SUBSTITUTED
WITH APPROVAL OF AUTHORITY HAVING JURISDICTION AND ARCHITECT
5. SEE DOOR SCHEDULE, SHEET A-600 FOR DOOR RATINGS. ALL RATED DOORS TO COMPLY WITH
IBC 716
6. ALL PENETRATIONS THROUGH FLOORS AND RATED WALLS TO BE FIRESTOPPED IN ACCORDANCE
WITH IBC CHAPTER 7
7. THE GC IS TO COORDINATE FIRE DEPARTMENT CONNECTION (FDC) LOCATION WITH AUTHORITY
HAVING JURISDICTION AND ARCHITECT
8. THE GC IS TO COORDINATE KNOX BOX LOCATION WITH FIRE DEPARTMENT AND ARCHITECT
CODE NOTES
2 7 10
L
8 954
B
J
C
K
1 3 11
H
G
D
E
F
A
M
19,620 SF
PARKING GARAGE
PARKING GARAGE
99 OCCUPANTS
2 EXITS REQ'D
S-2
200 SF/OCC
2'-9 5/8" PROVIDED
EXIT STAIR DOOR 5
10 OCCUPANTS
0.2"/OCC 2" REQ'D
2'-9 5/8" PROVIDED
EXIT STAIR DOOR 5.1
144 OCCUPANTS
0.2"/OCC 2'-4 3/4" REQ'D
2'-9 5/8" PROVIDED
EXIT STAIR 1.1
138 OCCUPANTS
0.2"/OCC 2'-3 5/8" REQ'D
12.02
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/1
/2
:5
:1
P
M A u to d e s k D o c s /1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
/1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
A
.r v t BO
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
Bo ul de r, Co
125020.00
20260309
100% IFC
LL PARKING GARAGE
BUILDING CODE PLAN
G-100
PROJECT FLAGNOTES
12.02 EXISTING 14 LONG TERM BIKE RACKS TO REMAIN
OCCUPANT LOAD CALCULATIONS - BY LEVEL - AREAS
OCCUPANCY OCCUPANT
LOAD
FACTOR
OCCUPANT
LOAD AREATABLE 1004.1.2 - USE DESCRIPTION
LL PARKING GARAGE
Parking Garages 200 99 19,620 SF
99 19,620 SF
GRAND TOTAL 99 19,620 SF
OCC GROUPS
S-2 19,620 SF
GRAND TOTAL 19,620 SF
TRUE
NORTH
0' 4' 8' 16' 32' 1/8" = 1'-0"
LL PARKING GARAGE- EGRESS CODE PLAN
NO DATE DESCRIPTION
WATERLINE EASEMENT
REC. NO. 2201480
M U
LC
H
D
IR
T
MULCH
N89°47'18"E 380.80' (C)
EAST 380.8' (TC)9
.9
N89°47'18"E 338.82' (C)
FE
FE
FE
F E
FE
F E
F E
FE
14 14
RK/36NRK/36N
T K
B D
/4
T
K B
D /4
TKBD16/48 TKBD16/48
TKBD16/36
TKBD16/42
TKBD16/36
TKBD16/42
TKBD16/30
F D
F /B
/4
F
D F
/B /4
FDF/B13/42FDF/B13/36
FDF/B13/48FDF/B13/48
FDF/B13/36
FDF/B13/42FDF/B13/42
S H
F /B
/4
SHF/B13/48
SHF/B13/36
SHF/B13/36 S
H
F /B
/4
SHF/B13/48
SHF/B42 SHF/B42
FDF/B13/42
COH
COH COH
COH
COH
COH
COH
COH
COH
COH
C O H
BROCHURE
STORAGE
OPTIONS - IN
ALL FACE TO
FACE ROOMS
BROCHURE STORAGE
OPTIONS - IN ALL FACE TO
FACE ROOMS
C H
-4
CH-4CH-4
C H
-4
CH-4CH-4CH-4
C H
-4
C H
-4
CH-4CH-4
CH-4
.9
31.78"
32.62"
38"
.6
51"
56"
-4
-7
40"
59.04"
.6
27.47" 49.80"
41"
.1
53"
.5
"6 .5
.5
59.09"
44.42"
54.78" 60.26"
46.25"
52.33"
64.28"
22.72"
.6
.1
54.39"
.6
ASSEMBLY RATING
NON-RATED ASSEMBLY
1 HOUR ASSEMBLY
2 HOUR ASSEMBLY
3 HOUR ASSEMBLY
4 HOUR ASSEMBLY
ASSEMBLY TYPE
BW BEARING WALL (IBC SECTION 704)
FW FIRE WALL (IBC SECTION 706)
FB FIRE BARRIER (IBC SECTION 707)
FP FIRE PARTITION (IBC SECTION 708)
SB SMOKE BARRIER (IBC SECTION 709)
SP SMOKE PARTITION (IBC SECTION 710)
SE SHAFT ENCLOSURE (IBC SECTION 713)
OCCUPANT LOAD
EGRESS DIRECTION
FIRE EXTINGUISHER
FE
FDC
FACP
KB KNOX BOX
EXIT ST-N
203 OCCUPANTS
0.2"/OCC = 3'-4" REQ'D
3'-8" PROVIDED
EXIT STAIR NAME OR
DOOR NUMBER
NUMBER OF OCCUPANTS
REQ'D EGRESS WIDTH
CALCULATIONS
PROVIDED EGRESS WIDTH
BIKE STORAGE
300 SF GROSS
ACCESSORY STORAGE
R-2
300 SF/OCC
2 OCCUPANTS
1 EXITS REQ'D
ROOM NAME
AREA & TYPE (GROSS OR NET)
FUNCTION OF SPACE
(TABLE 1004.1.2)
OCCUPANT LOAD FACTOR
TOTAL OCCUPANTS
EXITS REQUIRED
OCCUPANCY GROUP
GARAGE PATH
220'-10"
LOBBY PATH
30'-5"
TRAVEL DISTANCE PATH NAME
ACTUAL TRAVEL DISTANCE,
SEE SCHEDULE FOR
ALLOWABLE
EGRESS PATH
COMMON PATH OF TRAVEL NAME
ACTUAL TRAVEL DISTANCE,
SEE SCHEDULE FOR
ALLOWABLE
CONVERGENT OCCUPANT LOAD
EGRESS DIRECTION
FIRE DEPARTMENT
CONNECTION
FIRE ALARM
CONTROL PANEL
ACCESSIBLE PATH OF TRAVEL
EGRESS PATH
CODE SHEET GRAPHICS LEGEND
EXIT SIGN
CHAPTER 10 FUNCTION OF SPACE
ACCESSORY STORAGE
ASSEMBLY AREA
BUSINESS AREA
EDUCATIONAL
EXERCISE ROOM
7 10
L
8 954
B
J
C
K
1,216 SF
EDUCATIONAL
TRAINING
61 OCCUPANTS
2 EXITS REQ'D
A-3
20 SF/OCC
582 SF
EXERCISE ROOM
FITNESS
12 OCCUPANTS
1 EXITS REQ'D
A-3
50 SF/OCC
480 SF
ASSEMBLY AREA
LARGE
CONFERENCE
32 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
657 SF
ASSEMBLY AREA
BREAKROOM
44 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
3,260 SF
BUSINESS AREA
OPEN OFFICE - AREA
A
22 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
595 SF
EDUCATIONAL
WORKFORCE LAB
30 OCCUPANTS
1 EXITS REQ'D
B
20 SF/OCC
404 SF
BUSINESS AREA
PH/VR COUNTER
3 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
131 SF
ASSEMBLY AREA
HOSPITALITY
9 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
351 SF
ASSEMBLY AREA
WAITING
24 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
190 SF
BUSINESS AREA
CEDM
2 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
286 SF
ASSEMBLY AREA
ISSUANCE WAITING
20 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
1 3 11
H
G
D
E
F
A
170 SF
ACCESSORY STORAGE
STORAGE
1 OCCUPANTS
1 EXITS REQ'D
S-2
300 SF/OCC
100 SF
ACCESSORY STORAGE
WF STORAGE
1 OCCUPANTS
1 EXITS REQ'D
S-2
300 SF/OCC
92 SF
ASSEMBLY AREA
CHILDRENS
WAITIING
7 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
74 SF
ACCESSORY STORAGE
JC
1 OCCUPANTS
1 EXITS REQ'D
S-2
300 SF/OCC
FURNITURE STORAGE
CDEM EMER MGMT
TRAINING/BREAKOUT FACE TO FACE
SERVER ROOM
LOBBY
LARGE CONFERENCE/
WORKFORCE LAB
FACE TO FACE FACE TO FACE FACE TO FACE FACE TO FACE FACE TO FACE
W. RESTROOM
SECURITY/MAIL ROOM
HUDDLE ROOM
1,024 SF
BUSINESS AREA
OPEN OFFICE
7 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
FACE TO FACE
ELECTRICAL ROOM
STAFF SHOWER/RR
ISSUANCE AND SAFE
V R
S T
O R
ALL GENDERED
AAA / VETERANSAAA / VETERANS
TRAINING ROOM B
TRAINING ROOM A
CDEM / EMER MGMT
FACE TO FACE
FACE TO FACE
FACE TO FACE
FACE TO FACE
WIC / IMM. EXAM RM
WIC / IMM. EXAM RM
M. RESTROOM
STAIRS 2
STAIRS 3
LOBBY
PUB HEALTH VITAL RECORDS
319 SF
BUSINESS AREA
ISSUANCE/SAFE
3 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
325 SF
BUSINESS AREA
AAA / VETERANS
3 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
791 SF
BUSINESS AREA
FACE TO FACE
6 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
679 SF
BUSINESS AREA
RECEPTION
5 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
916 SF
BUSINESS AREA
OFFICE / FACE TO
FACE
7 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
22 79
M
R
EQ
U
IR
ED
SEPAR
ATIO
N
49'-9" /3 = 16'-6"
P R
O V
ID
E
D S
E P
A R
A T
IO
N
6' -1
0"
433 SF
BUSINESS AREA
BENEFITS
3 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
534 SF
BUSINESS AREA
LOBBY / OFFICE
4 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
2'-9 5/8" PROVIDED
EXIT STAIR DOOR 5.2
134 OCCUPANTS
0.2"/OCC 2'-2 3/4" REQ'D
193 SF
STAIR 5
EXIT 101A
33 OCCUPANTS
0.2"/OCC 6 5/8" REQ'D
6'-0" PROVIDED
2'-9 5/8" PROVIDED
EXIT STAIR DOOR1.2
142 OCCUPANTS
0.2"/OCC 2'-4 3/8" REQ'D
160 SF
STAIR 1
111 SF
BUSINESS AREA
WELLNESS RM
1 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
70 SF
ACCESSORY STORAGE
ENV HLTH REF STRG
1 OCCUPANTS
1 EXITS REQ'D
S-2
300 SF/OCC
TRAVEL
DISTANCE 1
TRAVEL
DISTANCE 2
COMMON PATH
OF TRAVEL 1
C O
M M
O N
P A
T H
O F
T R
A V
E L
EXIT STAIR 5
134 OCCUPANTS
0.2"/OCC MIN 3'-8" REQ'D
4'-1" PROVIDED
TRAVEL
DISTANCE 3
C O
M M
O N
P A
T H
O F
T R
A V
E L
COMMON PATH
OF TRAVEL 4
TRAVEL
DISTANCE 4
EXISTING STAIR
IS NOT CONSIDERED
A PATH OF EGRESS
STAIR TO INCLUDE
ACCESS CONTROL
D O
W N
U P
D O
W N
U P
EXIT STAIR 1
142 OCCUPANTS
0.3"/OCC MIN 3'-8" REQ'D
4'-1" PROVIDED
27.02
FACILITIES/ELEC
CLOSET
TELE
27.03
27.04
ACCESSIBLE PATH
1. BUILDING SHALL BE SPRINKLERED THROUGHOUT IN ACCORDANCE WITH IBC CHAPTER 9 AND
NFPA (13). PROVIDE DRY SPRINKLER SYSTEM WHERE APPROPRIATE AND AT ALL UNCONDITIONED
LOCATIONS
2. AREA OF REFUGE IS NOT REQUIRED PER 1009.3.3 EXCEPTION NO.2
3. ELEVATOR TO COMPLY WITH STRETCHER DIMENSIONS AS REQUIRED BY IBC CHAPTER 30
4. SEE A-000 SERIES SHEETS FOR LISTED ASSEMBLIES FOR FLOOR/CEILINGS, ROOF/CEILINGS, EXTERIOR WALLS, AND PARTITIONS. LISTED FIRE-RESISTIVE ASSEMBLIES MAY BE SUBSTITUTED
WITH APPROVAL OF AUTHORITY HAVING JURISDICTION AND ARCHITECT
5. SEE DOOR SCHEDULE, SHEET A-600 FOR DOOR RATINGS. ALL RATED DOORS TO COMPLY WITH
IBC 716
6. ALL PENETRATIONS THROUGH FLOORS AND RATED WALLS TO BE FIRESTOPPED IN ACCORDANCE
WITH IBC CHAPTER 7
7. THE GC IS TO COORDINATE FIRE DEPARTMENT CONNECTION (FDC) LOCATION WITH AUTHORITY
HAVING JURISDICTION AND ARCHITECT
8. THE GC IS TO COORDINATE KNOX BOX LOCATION WITH FIRE DEPARTMENT AND ARCHITECT
CODE NOTES
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/1
/2
:5
:2
P
M A u to d e s k D o c s /1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
/1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
A
.r v t BO
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
Bo ul de r, Co
125020.00
20260309
100% IFC
LEVEL 1 BUILDING CODE
PLAN
G-1011/8" = 1'-0"
LEVEL 1 - EGRESS CODE PLAN
OCCUPANT LOAD CALCULATIONS - BY LEVEL - AREAS
OCCUPANCY OCCUPANT
LOAD
FACTOR
OCCUPANT
LOAD AREATABLE 1004.1.2 - USE DESCRIPTION
LEVEL 1
Accessory storage areas, mechanical equipment room 300 1 70 SF
Accessory storage areas, mechanical equipment room 300 1 74 SF
Accessory storage areas, mechanical equipment room 300 1 170 SF
Accessory storage areas, mechanical equipment room 300 1 100 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 44 657 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 7 92 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 9 131 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 20 286 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 32 480 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 24 351 SF
Business Areas -150 150 3 325 SF
Business Areas -150 150 3 433 SF
Business Areas -150 150 2 190 SF
Business Areas -150 150 26 3,824 SF
Business Areas -150 150 6 791 SF
Business Areas -150 150 3 319 SF
Business Areas -150 150 4 534 SF
Business Areas -150 150 7 916 SF
Business Areas -150 150 7 1,024 SF
Business Areas -150 150 22 3,260 SF
Business Areas -150 150 3 404 SF
Business Areas -150 150 5 679 SF
Business Areas -150 150 11 1,317 SF
Business Areas -150 150 1 111 SF
Educational - Classroom area - Net Area 20 61 1,216 SF
Educational - Classroom area - Net Area 20 30 595 SF
Exercise Rooms 50 12 582 SF
346 18,931 SF
GRAND TOTAL 346 18,931 SF
OCC GROUPS
A-3 1,798 SF
B 16,718 SF
S-2 414 SF
GRAND TOTAL 18,931 SF
TRUE
NORTH
0' 4' 8' 16' 32'
EGRESS PATH LENGTH - FAMILY
PATH SEGMENT NAME PATH SEGMENT LENGTH
MAX DISTANCE
ALLOWED
COMMON PATH OF EGRESS
COMMON PATH OF TRAVEL 1 73' - 3" 100'-0"
COMMON PATH OF TRAVEL 2 57' - 6" 100'-0"
COMMON PATH OF TRAVEL 3 37' - 6" 100'-0"
COMMON PATH OF TRAVEL 4 58' - 11" 100'-0"
TRAVEL DISTANCE
TRAVEL DISTANCE 1 133' - 0" 300'-0"
TRAVEL DISTANCE 2 109' - 9" 300'-0"
TRAVEL DISTANCE 3 97' - 4" 300'-0"
TRAVEL DISTANCE 4 129' - 2" 300'-0"
PROJECT FLAGNOTES
27.02 EXISTING KNOX BOX LOCATION TO REMAIN.
27.03 EXISTING FACP LOCATION. DEVICES AND CONTROLS TO REMAIN.
27.04 EXISTING FACP CONTROLS TO REMAIN
DNF
E
FE FE
FE
F E
FE
F E
S E
T L
S T
SETL3ST
SETL3ST
06E
06E
E
E
J
J
E
60"
06E
06E
06E
06E 06E
06E
J
J
J
J
J
06E
J
E
E
J
J
06E
E
E
J
E
E
J
A-4491
A-463
15.67"
2'-10"
44.65"
55.30"
39.08"
.4
13'-7"
51.77"
11'
60"
65.91"
50.51"
10'-11"
5'-2"
13'-6"
120"
.3
.2
.5
43"
.5
62.91"
10'-5"
.9
23'-3"
85"
2'-1"
63.87"
42.00"
47.06"
47"
10'-8"
2'-4"
.0
52.40"
27'-9"
.5
58.88"
10'-9"10'-6"
.2
24'-11"
0'-10"
54.24"
.0
.8
47.06"
60.12"
22'-3"
62.90"
.7
37.69"
54.05" 48.51"
.9
50.53"
65.33"
54.90"
26.52"
.0
ASSEMBLY RATING
NON-RATED ASSEMBLY
1 HOUR ASSEMBLY
2 HOUR ASSEMBLY
3 HOUR ASSEMBLY
4 HOUR ASSEMBLY
ASSEMBLY TYPE
BW BEARING WALL (IBC SECTION 704)
FW FIRE WALL (IBC SECTION 706)
FB FIRE BARRIER (IBC SECTION 707)
FP FIRE PARTITION (IBC SECTION 708)
SB SMOKE BARRIER (IBC SECTION 709)
SP SMOKE PARTITION (IBC SECTION 710)
SE SHAFT ENCLOSURE (IBC SECTION 713)
OCCUPANT LOAD
EGRESS DIRECTION
FIRE EXTINGUISHER
FE
FDC
FACP
KB KNOX BOX
EXIT ST-N
203 OCCUPANTS
0.2"/OCC = 3'-4" REQ'D
3'-8" PROVIDED
EXIT STAIR NAME OR
DOOR NUMBER
NUMBER OF OCCUPANTS
REQ'D EGRESS WIDTH
CALCULATIONS
PROVIDED EGRESS WIDTH
BIKE STORAGE
300 SF GROSS
ACCESSORY STORAGE
R-2
300 SF/OCC
2 OCCUPANTS
1 EXITS REQ'D
ROOM NAME
AREA & TYPE (GROSS OR NET)
FUNCTION OF SPACE
(TABLE 1004.1.2)
OCCUPANT LOAD FACTOR
TOTAL OCCUPANTS
EXITS REQUIRED
OCCUPANCY GROUP
GARAGE PATH
220'-10"
LOBBY PATH
30'-5"
TRAVEL DISTANCE PATH NAME
ACTUAL TRAVEL DISTANCE,
SEE SCHEDULE FOR
ALLOWABLE
EGRESS PATH
COMMON PATH OF TRAVEL NAME
ACTUAL TRAVEL DISTANCE,
SEE SCHEDULE FOR
ALLOWABLE
CONVERGENT OCCUPANT LOAD
EGRESS DIRECTION
FIRE DEPARTMENT
CONNECTION
FIRE ALARM
CONTROL PANEL
ACCESSIBLE PATH OF TRAVEL
EGRESS PATH
CODE SHEET GRAPHICS LEGEND
EXIT SIGN
1. BUILDING SHALL BE SPRINKLERED THROUGHOUT IN ACCORDANCE WITH IBC CHAPTER 9 AND
NFPA (13). PROVIDE DRY SPRINKLER SYSTEM WHERE APPROPRIATE AND AT ALL UNCONDITIONED
LOCATIONS
2. AREA OF REFUGE IS NOT REQUIRED PER 1009.3.3 EXCEPTION NO.2
3. ELEVATOR TO COMPLY WITH STRETCHER DIMENSIONS AS REQUIRED BY IBC CHAPTER 30
4. SEE A-000 SERIES SHEETS FOR LISTED ASSEMBLIES FOR FLOOR/CEILINGS, ROOF/CEILINGS, EXTERIOR WALLS, AND PARTITIONS. LISTED FIRE-RESISTIVE ASSEMBLIES MAY BE SUBSTITUTED
WITH APPROVAL OF AUTHORITY HAVING JURISDICTION AND ARCHITECT
5. SEE DOOR SCHEDULE, SHEET A-600 FOR DOOR RATINGS. ALL RATED DOORS TO COMPLY WITH
IBC 716
6. ALL PENETRATIONS THROUGH FLOORS AND RATED WALLS TO BE FIRESTOPPED IN ACCORDANCE
WITH IBC CHAPTER 7
7. THE GC IS TO COORDINATE FIRE DEPARTMENT CONNECTION (FDC) LOCATION WITH AUTHORITY
HAVING JURISDICTION AND ARCHITECT
8. THE GC IS TO COORDINATE KNOX BOX LOCATION WITH FIRE DEPARTMENT AND ARCHITECT
CODE NOTES
2 7 10
L
8 954
B
J
C
K
CHAPTER 10 FUNCTION OF SPACE
ACCESSORY STORAGE
ASSEMBLY AREA
BUSINESS AREA
1 3 11
H
G
D
E
F
A
202 SF
ASSEMBLY AREA
CONF. RM
14 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
163 SF
ASSEMBLY AREA
CONF. RM
11 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
4,943 SF
BUSINESS AREA
OFFICE
33 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
200 SF
ASSEMBLY AREA
CONF. RM
14 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
377 SF
ASSEMBLY AREA
TRAINING RM
26 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
750 SF
ACCESSORY STORAGE
STORAGE
3 OCCUPANTS
1 EXITS REQ'D
S-2
300 SF/OCC
4,683 SF
BUSINESS AREA
OFFICE
32 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
394 SF
BUSINESS AREA
PRINT / COFFEE /
OPEN WK
3 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
493 SF
ACCESSORY STORAGE
STORAGE
2 OCCUPANTS
1 EXITS REQ'D
S-2
300 SF/OCC
202 SF
ASSEMBLY AREA
CONF. RM
14 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
212 SF
ASSEMBLY AREA
CONFERENCE
15 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
189 SF
ASSEMBLY AREA
PATIO
13 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
226 SF
ASSEMBLY AREA
PATIO
16 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
232 SF
ASSEMBLY AREA
PATIO
16 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
254 SF
ASSEMBLY AREA
PATIO
17 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
316 SF
ASSEMBLY AREA
PATIO
22 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
DHS STORAGE
CS OFFSITE EVENT AND
ADMIN STORAGE
IT STORAGE
DHS STORAGE
IT HELP DESKFACILITIES STORAGEFOCUS
BCPH/WIC/NFP OPEN
STORAGE
HARM REDUCTION
STORAGE
ENVIRONMENTAL
HEALTH STORAGE
EMER MGMT STORAGE
2,333 SF
BUSINESS AREA
OFFICE
16 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
631 SF
BUSINESS AREA
OPEN COLLAB
5 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
PUBLIC HEALTH
STORAGE
DIRECTOR OFFICE
DIRECTOR OFFICE DIRECTOR OFFICE
DIRECTOR OFFICE
CS AAA AGING
STORAGE
SERVER
OPEN WORK
M. RESTROOM
W. RESTROOM
TELE
JAN/ROOF
M
60' - 10"
MAX: 100
COMMON PATH OF TRAVEL 2B
160' - 7"
MAX: 300
TRAVEL DISTANCE 2A
149' - 9"
MAX: 300
TRAVEL DISTANCE 2B
M A
X : 1
C O
M M
O N
P A
T H
O F
T R
A V
E L
2A
0" M
A X
: 1
C O
M M
O N
P A
T H
O F
T R
A V
E L
2C
2'-9 5/8" PROVIDED
EXIT STAIR DOOR 1.3
117 OCCUPANTS
0.2"/OCC 1'-11 3/8" REQ'D
STAIR 5
STAIR 1
001.3
S T
A
IR
2'-9 5/8" PROVIDED
EXIT STAIR DOOR 5.3
167 OCCUPANTS
0.2"/OCC 2'-9 3/8" REQ'D
80 SF
BUSINESS AREA
WELLNESS
1 OCCUPANTS
1 EXITS REQ'D
B
150 SF/OCC
138 SF
ASSEMBLY AREA
OPEN MEETING
10 OCCUPANTS
1 EXITS REQ'D
B
15 SF/OCC
EXISTING STAIR
IS NOT CONSIDERED
A PATH OF EGRESS
STAIR HAS ACCESS
CONTROL
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/1
/2
:5
:2
P
M A u to d e s k D o c s /1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
/1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
A
.r v t BO
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
Bo ul de r, Co
125020.00
20260309
100% IFC
LEVEL 2 BUILDING CODE
PLAN
G-102
PROJECT FLAGNOTES
TRAVEL DISTANCE
PATH NAME ACTUAL DISTANCE MAX DISTANCE ALLOWED
LEVEL 2
TRAVEL DISTANCE 2A 160'-7" 300
TRAVEL DISTANCE 2B 149'-9" 300
COMMON PATH OF TRAVEL
PATH NAME ACTUAL DISTANCE MAX DISTANCE ALLOWED
LEVEL 2
COMMON PATH OF TRAVEL 2A 59'-11" 100
COMMON PATH OF TRAVEL 2B 60'-10" 100
COMMON PATH OF TRAVEL 2C 59'-0" 100
OCCUPANT LOAD CALCULATIONS - BY LEVEL - AREAS
OCCUPANCY OCCUPANT
LOAD
FACTOR
OCCUPANT
LOAD AREATABLE 1004.1.2 - USE DESCRIPTION
LEVEL 2
Accessory storage areas, mechanical equipment room 300 5 1,243 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 53 767 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 15 212 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 10 138 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 84 1,216 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 26 377 SF
Business Areas -150 150 13 1,604 SF
Business Areas -150 150 81 11,959 SF
Business Areas -150 150 5 631 SF
Business Areas -150 150 3 394 SF
Business Areas -150 150 5 643 SF
Business Areas -150 150 1 80 SF
301 19,263 SF
GRAND TOTAL 301 19,263 SF
OCC GROUPS
B 18,021 SF
S-2 1,243 SF
GRAND TOTAL 19,263 SF
TRUE
NORTH
0' 4' 8' 16' 32' 1/8" = 1'-0"
LEVEL 2-EGRESS CODE PLAN
PROJECT INFORMATION
APPLICABLE CODES:
2024 INTERNATIONAL BUILDING CODE (IBC)
2024 INTERNATIONAL FIRE CODE (IFC)
2024 INTERNATIONAL MECHANICAL CODE (IMC)
2024 INTERNATIONAL PLUMBING CODE (IPC)
2024 INTERNATIONAL FUEL AND GAS CODE (IFGC)
2024 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2017 ICC/ANSI A117.1, 2017
2023 NATIONAL ELECTRICAL CODE (NEC)
LOCAL AMENDMENTS
ZONING DESIGNATION: BC-2
FIRE SUPPRESSION: FULLY SPRINKLERED PER NFPA 13
PROJECT DESCRIPTION:
39,560 SF, 2 STORY NON-RESIDENTIAL BUILDING, OFFICE TENATE IMPROVEMENT, ROOF
REPLACEMENT. WORK TO EXCEED 50% OF BUILDING AREA.
USE AND OCCUPANCY CLASSIFICATION
MIXED USE NON SEPARATED OCCUPANCIES PER 508.3:
A-3 (ASSEMBLY) MOST RESTRICTIVE
B (BUSINESS)
S-2 (LOW HAZARD STORAGE)
BUILDING HEIGHT AND AREA
CONSTRUCTION TYPE(S): II B
FIRE RESISTANCE REQUIREMENTS
CONSTRUCTION TYPE: TYPE X
PRIMARY STRUCTURAL FRAME: 0
EXTERIOR BEARING WALLS*: 0
INTERIOR BEARING WALLS: 0
INTERIOR NON-BEARING WALLS: 0
FLOOR CONSTRUCTION: 0
ROOF CONSTRUCTION: 0
EXTERIOR NON-BEARING WALLS* BASED ON FIRE SEPARATION DISTANCE (FSD)
FSD < 5': 1
5' < FSD < 10': 1
10' < FSD < 30': 1
FSD > 30': 0
* EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE LESS THAN OR EQUAL TO 10' SHALL BE
RATED FOR EXPOSURE FROM BOTH SIDES.
CONSTRUCTION TYPE MATERIAL REQUIREMENTS:
NON RATED PER TYPE IIB:
ALLOWABLE AREA OF UNPROTECTED OPENINGS BASED ON FIRE SEPARATION DISTANCE:
0' - 3': NOT PERMITTED
3' - 5': 15% 5' - 10': 25% 10' - 15': 45% 15' - 20': 75%
> 20': NO LIMIT
EXIT REQUIREMENTS
EXIT WIDTH:
STAIRS: 0.3" PER OCCUPANT
OTHER COMPONENTS: 0.2 PER OCCUPANT
EXIT ACCESS TRAVEL DISTANCE (MAXIMUM LENGTH):
A-3: 250' B: 300' S-2: 400'
COMMON PATH OF EGRESS TRAVEL (MAXIMUM LENGTH):
A-3: 75' B: 100' S-2: 100'
FINISH CLASSIFICATIONS
ROOF COVERING CLASSIFICATION (MINIMUM): CLASS
INTERIOR WALL & CEILING FINISH REQUIREMENTS (MINIMUM):
EXIT STAIRS & EXIT PASSAGEWAYS: CLASS B
CORRIDORS & EXIT ACCESS STAIRS: CLASS C
ROOMS: CLASS C
IECC COMPLIANCE PATH
COMPLIANCE WITH IECC TO BE VERIFIED VIA ENERGY MODELING
ACCESSIBILITY
APPLICABLE CODES:
• PROJECT SHALL COMPLY WITH IBC CHAPTER 11, ICC/ANSI A117.1, (2017)
• PUBLIC & COMMON AREAS SHALL COMPLY WITH 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
PARKING REQUIREMENTS
VEHICLE PARKING REQUIREMENTS:
COMMERCIAL
SPACES REQUIRED: TOTAL 134 SPACES PER SITE REVIEW APPROVED
SEPTEMBER 2000: 80 STANDARD STALLS + 49 SMALL
CAR STALLS
ACCESSIBLE SPACES REQUIRED: 5 ACCESSIBLE SPACES
VEHICLE PARKING PROVIDED: 85 STANDARD STALLS + 41 SMALL CAR + 6
ACCESSIBLE SPACES. TOTAL: 132
PENDING ADMINISTRATIVE MODIFICATION:
#ADR2025-00334
BIKE PARKING REQUIREMENTS:
SPACES REQUIRED: PER SITE REVIEW APPROVED SEPTEMBER 2000: 14
BICYCLE SPACES
BIKE PARKING PROVIDED: 14 SHORT TERMN, 14 LONG TERM SPACES
BUILDING CODE SUMMARY
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/1
/2
:5
:2
P
M A u to d e s k D o c s /1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
/1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
A
.r v t BO
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
Bo ul de r, Co
125020.00
20260309
100% IFC
BUILDING CODE
SUMMARY
G-103
LL PARKING GARAGE
PARKING GARAGE 19,620 SF
LEVEL 1
TRAINING 1,216 SF
FITNESS 582 SF
LARGE CONFERENCE 480 SF
BREAKROOM 657 SF
OPEN OFFICE - AREA A 3,260 SF
WORKFORCE LAB 595 SF
PH/VR COUNTER 404 SF
HOSPITALITY 131 SF
WAITING 351 SF
CEDM 190 SF
ISSUANCE WAITING 286 SF
ISSUANCE/SAFE 319 SF
STORAGE 170 SF
WF STORAGE 100 SF
CHILDRENS WAITIING 92 SF
JC 74 SF
OPEN OFFICE 1,024 SF
AAA / VETERANS 325 SF
FACE TO FACE 791 SF
RECEPTION 679 SF
OFFICE / FACE TO FACE 916 SF
BENEFITS 433 SF
LOBBY / OFFICE 534 SF
RESTROOM 641 SF
RESTROOM 190 SF
WELLNESS RM 111 SF
ENV HLTH REF STRG 70 SF
CIRCULATION 1,754 SF
CIRCULATION 2,070 SF
RESTROOM 288 SF
RESTROOM 197 SF
LEVEL 2
CONF. RM 202 SF
CONF. RM 163 SF
OFFICE 4,943 SF
CONF. RM 200 SF
TRAINING RM 377 SF
STORAGE 750 SF
OFFICE 4,683 SF
PRINT / COFFEE / OPEN WK 394 SF
STORAGE 493 SF
CONF. RM 202 SF
CONFERENCE 212 SF
PATIO 189 SF
PATIO 226 SF
PATIO 232 SF
PATIO 254 SF
PATIO 316 SF
OFFICE 2,333 SF
OPEN COLLAB 631 SF
RESTROOMS 643 SF
WELLNESS 80 SF
CIRCULATION 99 SF
CIRCULATION 443 SF
CIRCULATION 98 SF
CIRCULATION 198 SF
CIRCULATION 172 SF
CIRCULATION 594 SF
OPEN MEETING 138 SF
GRAND TOTAL 57,814 SF
OCCUPANT LOAD BY LEVEL - AREAS
OCCUPANCY OCCUPANT
LOAD
FACTOR
OCCUPANT
LOAD AREATABLE 1004.1.2 - USE DESCRIPTION
LL PARKING GARAGE
Parking Garages 200 99 19,620 SF
99 19,620 SF
LEVEL 1
Accessory storage areas, mechanical equipment room 300 4 414 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 136 1,997 SF
Business Areas -150 150 103 14,126 SF
Educational - Classroom area - Net Area 20 91 1,811 SF
Exercise Rooms 50 12 582 SF
346 18,931 SF
LEVEL 2
Accessory storage areas, mechanical equipment room 300 5 1,243 SF
Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 188 2,711 SF
Business Areas -150 150 108 15,310 SF
301 19,263 SF
GRAND TOTAL 746 57,814 SF
PLUMBING FIXTURE CALCULATIONS - AREAS
OCCUPANCY
AREA
OCCUPANT
LOAD
DESIGN POPULATION WATER CLOSETS LAVS
DF
REQ'D.
DF
PROVIDEDTABLE 2902.1 CLASSIFICATION MEN WOMEN
MEN
REQ'D.
MEN
PROVIDED
WOMEN
REQ'D.
WOMEN
PROVIDED
MEN
REQ'D.
MEN
PROVIDED
WOMEN
REQ'D.
WOMEN
PROVIDED
LL PARKING GARAGE
S1 & S2 - Storage, Warehouses, Freight Depots 19,620 SF 0 0 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0
19,620 SF 0 0 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0
LEVEL 1
(none) 5,140 SF 0 0 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0
A3 - Auditoriums, Galleries, Museums, Lecture Halls, Libraries, Arcades and Gymnasiums 2,393 SF 100 50 50 0.40 1 0.77 2 0.25 1 0.25 1 0.20 0
B - Business 10,983 SF 205 103 103 3.06 4 3.06 4 2.29 3 2.29 4 2.05 4
S1 & S2 - Storage, Warehouses, Freight Depots 414 SF 4 2 2 0.02 1 0.02 1 0.02 0 0.02 0 0.00 0
18,931 SF 309 155 155 3.48 6 3.85 7 2.56 4 2.56 5 2.25 4
LEVEL 2
(none) 2,877 SF 0 0 0 0.00 0 0.00 0 0.00 0 0.00 0 0.00 0
B - Business 15,144 SF 279 140 140 3.80 4 3.80 3 2.75 2 2.75 2 2.79 2
S1 & S2 - Storage, Warehouses, Freight Depots 1,243 SF 5 3 3 0.03 0 0.03 0 0.03 0 0.03 0 0.00 0
19,263 SF 284 143 143 3.83 4 3.83 3 2.78 2 2.78 2 2.79 2
OCCUPANT LOAD CALCULATIONS - AREAS
NAME AREA
OCCUPANCY
GROUP
OCCUPANCY OCCUPANT
LOAD
FACTOR
OCCUPANT
LOADTABLE 1004.1.2 - USE DESCRIPTION
LL PARKING GARAGE
PARKING GARAGE 19,620 SF S-2 Parking Garages 200 99
19,620 SF 99
LEVEL 1
ENV HLTH REF STRG 70 SF S-2 Accessory storage areas, mechanical equipment room 300 1
JC 74 SF S-2 Accessory storage areas, mechanical equipment room 300 1
STORAGE 170 SF S-2 Accessory storage areas, mechanical equipment room 300 1
WF STORAGE 100 SF S-2 Accessory storage areas, mechanical equipment room 300 1
BREAKROOM 657 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 44
CHILDRENS WAITIING 92 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 7
HOSPITALITY 131 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 9
ISSUANCE WAITING 286 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 20
LARGE CONFERENCE 480 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 32
WAITING 351 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 24
AAA / VETERANS 325 SF B Business Areas -150 150 3
BENEFITS 433 SF B Business Areas -150 150 3
CEDM 190 SF B Business Areas -150 150 2
CIRCULATION 3,824 SF B Business Areas -150 150 26
FACE TO FACE 791 SF B Business Areas -150 150 6
ISSUANCE/SAFE 319 SF B Business Areas -150 150 3
LOBBY / OFFICE 534 SF B Business Areas -150 150 4
OFFICE / FACE TO FACE 916 SF B Business Areas -150 150 7
OPEN OFFICE 1,024 SF B Business Areas -150 150 7
OPEN OFFICE - AREA A 3,260 SF B Business Areas -150 150 22
PH/VR COUNTER 404 SF B Business Areas -150 150 3
RECEPTION 679 SF B Business Areas -150 150 5
RESTROOM 1,317 SF B Business Areas -150 150 11
WELLNESS RM 111 SF B Business Areas -150 150 1
TRAINING 1,216 SF A-3 Educational - Classroom area - Net Area 20 61
WORKFORCE LAB 595 SF B Educational - Classroom area - Net Area 20 30
FITNESS 582 SF A-3 Exercise Rooms 50 12
18,931 SF 346
LEVEL 2
STORAGE 1,243 SF S-2 Accessory storage areas, mechanical equipment room 300 5
CONF. RM 767 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 53
CONFERENCE 212 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 15
OPEN MEETING 138 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 10
PATIO 1,216 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 84
TRAINING RM 377 SF B Assembly Areas without fixed seats, Unconcentrated (tables and chairs) - Net Area
15 26
CIRCULATION 1,604 SF B Business Areas -150 150 13
OFFICE 11,959 SF B Business Areas -150 150 81
OPEN COLLAB 631 SF B Business Areas -150 150 5
PRINT / COFFEE / OPEN WK 394 SF B Business Areas -150 150 3
RESTROOMS 643 SF B Business Areas -150 150 5
WELLNESS 80 SF B Business Areas -150 150 1
19,263 SF 301
GRAND TOTAL 57,814 SF 746
*** CIRCULATION, CORRIDORS AND RESTROOMS OCCUPANT LOAD NOT INCLUDED IN PLUMBING FIXTURE COUNTS
PROJECT NUMBER:
DATE:
SHEET NUMBER
SHEET TITLE:
ISSUED FOR:
REVISIONS:
/1
/2
:5
:3
P
M A u to d e s k D o c s /1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
/1
.0
B o u ld e r
C o u n ty
C o m m u n it y H u b
A
.r v t BO
U
LD
ER
C
O U
N
TY
C O
M M
U N
IT
Y
H U
B
8t h
St
Bo ul de r, Co
125020.00
20260309
100% IFC
ENERGY COMPLIANCE
CHECKLIST
G-400
SIGNAGE TYPE SCHEDULE - IBC 2024
SIGN
DESIGNATION
A
SIGN TYPE
ROOM NUMBER
LOCATION
AS INDICATED ON PLANS
CODE REFERENCE
VISUAL
CHARACTERS
YES
TACTILE BRAILLE PICTOGRAM
INT'L SYMBOL OF
ACCESSIBILITY PLACEMENT
POST OR BUILDING-MOUNTED CENTERED ON PARKING SPACE, 0" TO BOTTOM OF SIGN
COMMENTS
B
ACCESSIBLE ENTRANCE ENTRANCES WHERE NOT ALL ARE ACCESSIBLE ENTRANCE TO ELEMENT
C
AREA OF REFUGE AREAS OF REFUGE & EXTERIOR AREAS FOR EVACUATION ASSISTANCE
D
ACCESSIBLE PARKING PAVEMENT MARKING ACCESSIBLE PARKING STALLS CENTERED ON PARKING STALL, ALIGNED WITH FRONT NOT REQUIRED BY CODE
E
ASSISTIVE LISTENING SYSTEM ASSEMBLY SPACES WITH ASSISTIVE LISTENING SYSTEM NEAR ENTRANCE TO ROOM PICTOGRAM TO BE INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
F
2-WAY COMMUNICATION ADJACENT TO 2-WAY COMMUNICATION DEVICES INCLUDING ELEVATOR LANDINGS AT LEVEL 2 AND ABOVE ADJACENT TO 2-WAY COMMUNICATION DEVICES
G
DIRECTIONAL INACCESSIBLE ENTRANCES, TOILET ROOMS & BATHING FACILITIES, ELEVATORS NOT SERVING AN ACCESSIBLE ROUTE, EXITS & EXIT STAIRS NOT PROVIDING AN ACCESSIBLE MEANS OF EGRESS, ELEVATOR LANDINGS &
WITHIN AREAS OF REFUGE
H
TOILET ROOM ACCESSIBLE TOILET ROOMS
I
STAIR IDENTIFICATION INSIDE STAIR ENCLOSURE AT EACH STAIR LANDING VISIBLE WHEN DOOR IS OPEN OR CLOSED
J
EXIT STAIR EXIT STAIRS ABOVE EACH ELEVATOR CALL BUTTON NOT USED AT ENTRY LEVEL & ELEVATORS PART OF AN ACCESSIBLE MEANS OF EGRESS OR USED FOR SELF-EVACUATION
K
EMPLOYEE ONLY AS INDICATED ON PLANS BOTH ELEVATOR JAMBS
L
ROOM IDENTIFICATION OUTSIDE ROOM ROOM SIGNS ARE NOT REQUIRED BUT IF PROVIDED THEY MUST MEET REQUIREMENTS
M LOCKED DOOR MAIN ENTRY DOORS WITH LOCKS DOOR FRAME ABOVE DOOR ALLOWED AT MAIN DOORS OF GROUP A WITH A MAXIMUM OCCUPANT LOAD OF 300 AND GROUP B, F, M & S
N
RATED WALL ABOVE CEILING AT ALL RATED WALLS WITHIN 15' OF END OF WALL & 30' O.C. ALONG LENGTH OF WALL NOT REQUIRED IN R-2 OCCUPANCY WHERE CEILING IS NOT ACCESSIBLE
O
MAXIMUM OCCUPANCY ASSEMBLY OCCUPANCY SPACES CONSPICUOUS PLACE NEAR MAIN DOOR MAXIMUM OCCUPANCY OF ROOM PER CODE PLAN
P
TACTILE EXIT DOORS AT: EXTERIOR EXIT DOORS, EXIT STAIRS & RAMPS, EXIT PASSAGEWAYS, AREAS OF REFUGE, AND EXTERIOR AREAS FOR RESCUE ASSISTANCE
Q
R NO SMOKING BUILDING ENTRIES CONSPICUOUS PLACE NEAR DOOR REQUIRED FOR LEED
S
STOP SIGN AS INDICATED ON PLANS POST-MOUNTED, 5'-0" TO BOTTOM OF SIGN
TRAFFIC AS INDICATED ON PLANS POST OR BUILDING-MOUNTED, 5'-0" TO BOTTOM OF SIGN
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
YES
NO
NO
NO
NO
YES
YES
NO
YES
YES
NO
NO
NO
YES
NO
NO
NO
NO
NO
NO
NO
YES
YES
NO
YES
NO
YES
NO
NO
NO
NO
NO
NO
YES
NO
NO
YES
YES
YES
YES
NO
NO
YES
YES
NO
NO
YES
NO
NO
NO
NO
YES
YES
NO
YES
YES
NO
NO
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
SEE PLAN FOR SIGN CONTENT
IBC 1111.1
IBC 1009.9 & 1009.11
NA
IBC 1111.3 & 1108.2.7
IBC 1009.8.2, 1009.10 & 1009.11
IBC 1111.1 & 1009.10
IBC 2902.4 & 1111
IBC 1023.9
ADAAG 216.2
IBC 1010.1.9.4
IBC 703.7
IBC 1004.9
IBC 1013.4
NA
NA
NA
AT DOOR TO REFUGE AREA ILLUMINATION ALSO REQUIRED
NA
NA
NA
NOTES:
1. SIGNAGE TO COMPLY WITH ICC A.117.1 703.2 AND ADA CHAPTER 7.
2. SIGNAGE TO COMPLY WITH COLORADO
3. MOUNT SIGNS 4" CLEAR TO LATCH-SIDE DOOR JAMB U.O.N
4. MOUNT TOP OF SIGNS AT 5'-0" AFF U.O.N.
5. WHEN TWO SIGNS ARE NEXT TO EACH OTHER, ALIGN TOP HEIGHT U.O.N.
6. WHERE NOTED IN SCHEDULE, SPANISH TEXT AND LINE ABOVE TO BE FLAT (IN VINYL
WHEN DONE BY CLIENT)
7. TYPICAL SIGN ON 1/8" THICK BASE, OVER 1/16" THICK BACKDROP, 3/8" OFFSET
8. BRAILLE INDICATED BELOW IS ONLY REPRESENTATIVE FOR LOCATION AND SIZE
Name Spanish
/2
/2
/8
/8
" 2
NAME
1" TEXT RAISED 1/32"
GRADE 2 BRAILE
VINYL LINE BY CLIENT
VINYL SPANISH
BY CLIENT
WHERE NOTED
PICTOGRAM RAISED 1/32"
VARIES
TEXT
TEXT
/2
/8
/8
/8
/8
/4
/4
3/8" 5 1/4" 3/8"
1" TEXT RAISED 1/32"
GRADE 2 BRAILE
PICTOGRAM
3"
E Q
/4
/8
/8
E Q
5/8" TEXT
RAISED 1/32"
SIGN BASE,
TYPICAL
GRADE 2
BRAILE
R# - ROOM NUMBER
3X3
ROOM NAME MEDIUM
9x3
NAME
NAME
E Q
/8
/8
/8
/8
/4
E Q
GRADE 2
BRAILE
9"
ROOM NAME LARGE (2 VERSIONS)
9X6
NAME
E Q
/8
/8
/4
E Q
6"
NAME
NAME
E Q
/8
/8
/8
/8
/4
E Q
GRADE 2
BRAILE
9"
DIVISION SIGN
9X6
NAME
E Q
/8
/8
/4
E Q
9"
5/8" TEXT
RAISED 1/32"
5/8" TEXT
RAISED 1/32"
6"
5/8" TEXT
RAISED 1/32"
GRADE 2
BRAILE
RS - ROOM SUITE
6X6
E Q
RESTROOM
BANO
/2
/2
/8
/8
/4
/4
9"
3/8" 5 1/4" 3/8"
VARIES
RESTROOM
BANO
/2
/8
/8
/4
/…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .